This study aimed to define the histopathology of degenerated humeral head cartilage and synovial inflammation of the glenohumeral joint in patients with omarthrosis (OmA) and cuff tear arthropathy (CTA). Additionally, the potential of immunohistochemical tissue biomarkers in reflecting the degeneration status of humeral head cartilage was evaluated. Specimens of the humeral head and synovial tissue from 12 patients with OmA, seven patients with CTA, and four body donors were processed histologically for examination using different histopathological scores. Osteochondral sections were immunohistochemically stained for collagen type I, collagen type II, collagen neoepitope C1,2C, collagen type X, and osteocalcin, prior to semiquantitative analysis. Matrix metalloproteinase (MMP)-1, MMP-3, and MMP-13 levels were analyzed in synovial fluid using enzyme-linked immunosorbent assay (ELISA).Aims
Methods
The aim of this study was to create artificial intelligence (AI) software with the purpose of providing a second opinion to physicians to support distal radius fracture (DRF) detection, and to compare the accuracy of fracture detection of physicians with and without software support. The dataset consisted of 26,121 anonymized anterior-posterior (AP) and lateral standard view radiographs of the wrist, with and without DRF. The convolutional neural network (CNN) model was trained to detect the presence of a DRF by comparing the radiographs containing a fracture to the inconspicuous ones. A total of 11 physicians (six surgeons in training and five hand surgeons) assessed 200 pairs of randomly selected digital radiographs of the wrist (AP and lateral) for the presence of a DRF. The same images were first evaluated without, and then with, the support of the CNN model, and the diagnostic accuracy of the two methods was compared.Aims
Methods
Rotator cuff tear (RCT) is the leading cause of shoulder pain, primarily associated with age-related tendon degeneration. This study aimed to elucidate the potential differential gene expressions in tendons across different age groups, and to investigate their roles in tendon degeneration. Linear regression and differential expression (DE) analyses were performed on two transcriptome profiling datasets of torn supraspinatus tendons to identify age-related genes. Subsequent functional analyses were conducted on these candidate genes to explore their potential roles in tendon ageing. Additionally, a secondary DE analysis was performed on candidate genes by comparing their expressions between lesioned and normal tendons to explore their correlations with RCTs.Aims
Methods
Rotator cuff (RC) injuries are characterized by tendon rupture, muscle atrophy, retraction, and fatty infiltration, which increase injury severity and jeopardize adequate tendon repair. Epigenetic drugs, such as histone deacetylase inhibitors (HDACis), possess the capacity to redefine the molecular signature of cells, and they may have the potential to inhibit the transformation of the fibro-adipogenic progenitors (FAPs) within the skeletal muscle into adipocyte-like cells, concurrently enhancing the myogenic potential of the satellite cells. HDACis were added to FAPs and satellite cell cultures isolated from mice. The HDACi vorinostat was additionally administered into a RC injury animal model. Histological analysis was carried out on the isolated supra- and infraspinatus muscles to assess vorinostat anti-muscle degeneration potential.Aims
Methods
Rotator cuff muscle atrophy and fatty infiltration affect the clinical outcomes of rotator cuff tear patients. However, there is no effective treatment for fatty infiltration at this time. High-intensity interval training (HIIT) helps to activate beige adipose tissue. The goal of this study was to test the role of HIIT in improving muscle quality in a rotator cuff tear model via the β3 adrenergic receptor (β3AR). Three-month-old C57BL/6 J mice underwent a unilateral rotator cuff injury procedure. Mice were forced to run on a treadmill with the HIIT programme during the first to sixth weeks or seventh to 12th weeks after tendon tear surgery. To study the role of β3AR, SR59230A, a selective β3AR antagonist, was administered to mice ten minutes before each exercise through intraperitoneal injection. Supraspinatus muscle, interscapular brown fat, and inguinal subcutaneous white fat were harvested at the end of the 12th week after tendon tear and analyzed biomechanically, histologically, and biochemically.Aims
Methods
An objective technological solution for tracking adherence to at-home shoulder physiotherapy is important for improving patient engagement and rehabilitation outcomes, but remains a significant challenge. The aim of this research was to evaluate performance of machine-learning (ML) methodologies for detecting and classifying inertial data collected during in-clinic and at-home shoulder physiotherapy exercise. A smartwatch was used to collect inertial data from 42 patients performing shoulder physiotherapy exercises for rotator cuff injuries in both in-clinic and at-home settings. A two-stage ML approach was used to detect out-of-distribution (OOD) data (to remove non-exercise data) and subsequently for classification of exercises. We evaluated the performance impact of grouping exercises by motion type, inclusion of non-exercise data for algorithm training, and a patient-specific approach to exercise classification. Algorithm performance was evaluated using both in-clinic and at-home data.Aims
Methods
The optimal choice of management for proximal humerus fractures (PHFs) has been increasingly discussed in the literature, and this work aimed to answer the following questions: 1) what are the incidence rates of PHF in the geriatric population in the USA; 2) what is the mortality rate after PHF in the elderly population, specifically for distinct treatment procedures; and 3) what factors influence the mortality rate? PHFs occurring between 1 January 2009 and 31 December 2019 were identified from the Medicare physician service records. Incidence rates were determined, mortality rates were calculated, and semiparametric Cox regression was applied, incorporating 23 demographic, clinical, and socioeconomic covariates, to compare the mortality risk between treatments.Aims
Methods
Rotator cuff (RC) tears are common musculoskeletal injuries which often require surgical intervention. Noninvasive pulsed electromagnetic field (PEMF) devices have been approved for treatment of long-bone fracture nonunions and as an adjunct to lumbar and cervical spine fusion surgery. This study aimed to assess the effect of continuous PEMF on postoperative RC healing in a rat RC repair model. A total of 30 Wistar rats underwent acute bilateral supraspinatus tear and repair. A miniaturized electromagnetic device (MED) was implanted at the right shoulder and generated focused PEMF therapy. The animals’ left shoulders served as controls. Biomechanical, histological, and bone properties were assessed at three and six weeks.Aims
Methods
To evaluate if union of clavicle fractures can be predicted at six weeks post-injury by the presence of bridging callus on ultrasound. Adult patients managed nonoperatively with a displaced mid-shaft clavicle were recruited prospectively. Ultrasound evaluation of the fracture was undertaken to determine if sonographic bridging callus was present. Clinical risk factors at six weeks were used to stratify patients at high risk of nonunion with a combination of Quick Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH) ≥ 40, fracture movement on examination, or absence of callus on radiograph.Aims
Methods
Indocyanine green (ICG) fluorescence angiography is an emerging technique that can provide detailed anatomical information during surgery. The purpose of this study is to determine whether ICG fluorescence angiography can be used to evaluate the blood flow of the rotator cuff tendon in the clinical setting. Twenty-six patients were evaluated from October 2016 to December 2017. The participants were categorized into three groups based on their diagnoses: the rotator cuff tear group; normal rotator cuff group; and adhesive capsulitis group. After establishing a posterior standard viewing portal, intravenous administration of ICG at 0.2 mg/kg body weight was performed, and fluorescence images were recorded. The time from injection of the drug to the beginning of enhancement of the observed area was measured. The hypovascular area in the rotator cuff was evaluated, and the ratio of the hypovascular area to the anterolateral area of the rotator cuff tendon was calculated (hypovascular area ratio).Objectives
Methods
Plating displaced proximal humeral fractures is associated with a high rate of screw perforation. Dynamization of the proximal screws might prevent these complications. The aim of this study was to develop and evaluate a new gliding screw concept for plating proximal humeral fractures biomechanically. Eight pairs of three-part humeral fractures were randomly assigned for pairwise instrumentation using either a prototype gliding plate or a standard PHILOS plate, and four pairs were fixed using the gliding plate with bone cement augmentation of its proximal screws. The specimens were cyclically tested under progressively increasing loading until perforation of a screw. Telescoping of a screw, varus tilting and screw migration were recorded using optical motion tracking.Aims
Methods
The objective of this study was to perform a meta-analysis of all randomised controlled trials (RCTs) comparing surgical and non-surgical management of fractures of the proximal humerus, and to determine whether further analyses based on complexity of fracture, or the type of surgical intervention, produced disparate findings on patient outcomes. A systematic review of the literature was performed identifying all RCTs that compared surgical and non-surgical management of fractures of the proximal humerus. Meta-analysis of clinical outcomes was performed where possible. Subgroup analysis based on the type of fracture, and a sensitivity analysis based on the type of surgical intervention, were also performed.Objectives
Methods
Injectable Bromelain Solution (IBS) is a modified investigational derivate of the medical grade bromelain-debriding pharmaceutical agent (NexoBrid) studied and approved for a rapid (four-hour single application), eschar-specific, deep burn debridement. We conducted an Specially prepared medical grade IBS was injected into fresh Dupuytren’s cords excised from patients undergoing surgical fasciectomy. These cords were tested by tension-loading them to failure with the Zwick 1445 (Zwick GmbH & Co. KG, Ulm, Germany) tension testing system.Objectives
Materials and Methods
The aim of this study was to compare the pain caused by the application
of a tourniquet after exsanguination of the upper limb with that
occurring after simple elevation. We used 26 healthy volunteers (52 arms), each of whom acted as
their own matched control. The primary outcome measure was the total pain experienced by
each volunteer while the tourniquet was inflated for 20 minutes.
This was calculated as the area under the pain curve for each individual
subject. Secondary outcomes were pain at each time point; the total
pain experienced during the recovery phase; the ability to tolerate the
tourniquet and the time for full recovery after deflation of the
tourniquet. Aims
Patients and Methods
Between 2005 and 2012, 50 patients (23 female, 27 male) with
nonunion of the humeral shaft were included in this retrospective
study. The mean age was 51.3 years (14 to 88). The patients had
a mean of 1.5 prior operations ( All patients were assessed according to a specific risk score
in order to devise an optimal and individual therapy plan consistent
with the Diamond Concept. In 32 cases (64%), a change in the osteosynthesis
to an angular stable locking compression plate was performed. According
to the individual risk an additional bone graft and/or bone morphogenetic
protein-7 (BMP-7) were applied. A successful consolidation of the nonunion was observed in 37
cases (80.4%) with a median healing time of six months (IQR 6).
Younger patients showed significantly better consolidation. Four
patients were lost to follow-up. Revision was necessary in a total
of eight (16%) cases. In the initial treatment, intramedullary nailing
was most common. Methods
Results
Necrotising soft-tissue infections (NSTIs) of
the upper limb are uncommon, but potentially life-threatening. We
used a national database to investigate the risk factors for amputation
of the limb and death. We extracted data from the Japanese Diagnosis Procedure Combination
database on 116 patients (79 men and 37 women) who had a NSTI of
the upper extremity between 2007 and 2010. The overall in-hospital mortality was 15.5%. Univariate analysis
of in-hospital mortality showed that the significant variables were
age (p = 0.015), liver dysfunction (p = 0.005), renal dysfunction
(P <
0.001), altered consciousness (p = 0.049), and sepsis (p
= 0.021). Logistic regression analysis showed that the factors associated with
death in hospital were age over 70 years (Odds Ratio (OR) 6.6; 95%
confidence interval (CI) 1.5 to 28.2; p = 0.011) and renal dysfunction
(OR 15.4; 95% CI 3.8 to 62.8; p <
0.001). Univariate analysis of limb amputation showed that the significant
variables were diabetes (p = 0.017) mellitus and sepsis (p = 0.001).
Multivariable logistic regression analysis showed that the factors
related to limb amputation were sepsis (OR 1.8; 95% CI 1.5 to 24.0;
p = 0.013) and diabetes mellitus (OR 1.6; 95% CI 1.1 to 21.1; p
= 0.038). For NSTIs of the upper extremity, advanced age and renal dysfunction
are both associated with a higher rate of in-hospital mortality.
Sepsis and diabetes mellitus are both associated with a higher rate
of amputation. Cite this article:
We present a review of claims made to the NHS
Litigation Authority (NHSLA) by patients with conditions affecting the
shoulder and elbow, and identify areas of dissatisfaction and potential
improvement. Between 1995 and 2012, the NHSLA recorded 811 claims
related to the shoulder and elbow, 581 of which were settled. This
comprised 364 shoulder (64%), and 217 elbow (36%) claims. A total
of £18.2 million was paid out in settled claims. Overall diagnosis,
mismanagement and intra-operative nerve injury were the most common
reasons for litigation. The highest cost paid out resulted from
claims dealing with incorrect, missed or delayed diagnosis, with
just under £6 million paid out overall. Fractures and dislocations
around the shoulder and elbow were common injuries in this category.
All 11 claims following wrong-site surgery that were settled led
to successful payouts. This study highlights the diagnoses and procedures that need
to be treated with particular vigilance. Having an awareness of
the areas that lead to litigation in shoulder and elbow surgery
will help to reduce inadvertent risks to patients and prevent dissatisfaction
and possible litigation. Cite this article:
Traumatic brachial plexus injury causes severe functional impairment
of the arm. Elbow flexion is often affected. Nerve surgery or tendon
transfers provide the only means to obtain improved elbow flexion.
Unfortunately, the functionality of the arm often remains insufficient.
Stem cell therapy could potentially improve muscle strength and
avoid muscle-tendon transfer. This pilot study assesses the safety
and regenerative potential of autologous bone marrow-derived mononuclear
cell injection in partially denervated biceps. Nine brachial plexus patients with insufficient elbow flexion
(i.e., partial denervation) received intramuscular escalating doses
of autologous bone marrow-derived mononuclear cells, combined with
tendon transfers. Effect parameters included biceps biopsies, motor
unit analysis on needle electromyography and computerised muscle tomography,
before and after cell therapy.Objectives
Methods
We hypothesised that a large acromial cover with
an upwardly tilted glenoid fossa would be associated with degenerative
rotator cuff tears (RCTs), and conversely, that a short acromion
with an inferiorly inclined glenoid would be associated with glenohumeral
osteoarthritis (OA). This hypothesis was tested using a new radiological parameter,
the critical shoulder angle (CSA), which combines the measurements
of inclination of the glenoid and the lateral extension of the acromion
(the acromion index). The CSA was measured on standardised radiographs of three groups:
1) a control group of 94 asymptomatic shoulders with normal rotator
cuffs and no OA; 2) a group of 102 shoulders with MRI-documented
full-thickness RCTs without OA; and 3) a group of 102 shoulders
with primary OA and no RCTs noted during total shoulder replacement.
The mean CSA was 33.1° (26.8° to 38.6°) in the control group, 38.0°
(29.5° to 43.5°) in the RCT group and 28.1° (18.6° to 35.8°) in
the OA group. Of patients with a CSA >
35°, 84% were in the RCT
group and of those with a CSA <
30°, 93% were in the OA group. We therefore concluded that primary glenohumeral OA is associated
with significantly smaller degenerative RCTs with significantly
larger CSAs than asymptomatic shoulders without these pathologies.
These findings suggest that individual quantitative anatomy may
imply biomechanics that are likely to induce specific types of degenerative
joint disorders. Cite this article:
We performed a systematic review of the literature to determine
whether earlier surgical repair of acute rotator cuff tear (ARCT)
leads to superior post-operative clinical outcomes. The MEDLINE, Embase, CINAHL, Web of Science, Cochrane Libraries,
controlled-trials.com and clinicaltrials.gov databases were searched
using the terms: ‘rotator cuff’, or ‘supraspinatus’, or ‘infraspinatus’,
or ‘teres minor’, or ‘subscapularis’ AND ‘surgery’ or ‘repair’.
This gave a total of 15 833 articles. After deletion of duplicates
and the review of abstracts and full texts by two independent assessors,
15 studies reporting time to surgery for ARCT repair were included.
Studies were grouped based on time to surgery <
3 months (group
A, seven studies), or >
3 months (group B, eight studies). Weighted
means were calculated and compared using Student’s Aims
Methods
The purpose of this study was to compare the
outcome and complications of endoscopic We conclude that endoscopic release for de Quervain’s tenosynovitis
seems to provide earlier improvement after surgery, with fewer superficial
radial nerve complications and greater scar satisfaction, when compared
with open release. Cite this article:
To report the five-year results of a randomised controlled trial
examining the effectiveness of arthroscopic acromioplasty in the
treatment of stage II shoulder impingement syndrome. A total of 140 patients were randomly divided into two groups:
1) supervised exercise programme (n = 70, exercise group); and 2)
arthroscopic acromioplasty followed by a similar exercise programme
(n = 70, combined treatment group).Objectives
Methods
There is little published information on the
health impact of frozen shoulder. The purpose of this study was
to assess the functional and health-related quality of life outcomes
following arthroscopic capsular release (ACR) for contracture of
the shoulder. Between January 2010 and January 2012 all patients
who had failed non-operative treatment including anti-inflammatory
medication, physiotherapy and glenohumeral joint injections for
contracture of the shoulder and who subsequently underwent an ACR
were enrolled in the study. A total of 100 patients were eligible;
68 underwent ACR alone and 32 had ACR with a subacromial decompression
(ASD). ACR resulted in a highly significant improvement in the range
of movement and functional outcome, as measured by the Oxford shoulder
score and EuroQol EQ-5D index. The mean cost of a quality-adjusted
life year (QALY) for an ACR and ACR with an ASD was £2563 and £3189,
respectively. ACR is thus a cost-effective procedure that can restore relatively
normal function and health-related quality of life in most patients
with a contracture of the shoulder within six months after surgery;
and the beneficial effects are not related to the duration of the
presenting symptoms. Cite this article:
Most patients with a nightstick fracture of the
ulna are treated conservatively. Various techniques of immobilisation or
early mobilisation have been studied. We performed a systematic
review of all published randomised controlled trials and observational
studies that have assessed the outcome of these fractures following
above- or below-elbow immobilisation, bracing and early mobilisation.
We searched multiple electronic databases, related bibliographies and
other studies. We included 27 studies comprising 1629 fractures
in the final analysis. The data relating to the time to radiological
union and the rates of delayed union and nonunion could be pooled
and analysed statistically. We found that early mobilisation produced the shortest radiological
time to union (mean 8.0 weeks) and the lowest mean rate of nonunion
(0.6%). Fractures treated with above- or below-elbow immobilisation
and braces had longer mean radiological times to union (9.2 weeks,
9.2 weeks and 8.7 weeks, respectively) and higher mean rates of
nonunion (3.8%, 2.1% and 0.8%, respectively). There was no statistically
significant difference in the rate of non- or delayed union between
those treated by early mobilisation and the three forms of immobilisation
(p = 0.142 to p = 1.000, respectively). All the studies had significant
biases, but until a robust randomised controlled trial is undertaken
the best advice for the treatment of undisplaced or partially displaced
nightstick fractures appears to be early mobilisation, with a removable
forearm support for comfort as required. Cite this article:
This study was performed to determine whether
pure cancellous bone graft and Kirschner (K-) wire fixation were sufficient
to achieve bony union and restore alignment in scaphoid nonunion.
A total of 65 patients who underwent cancellous bone graft and K-wire
fixation were included in this study. The series included 61 men
and four women with a mean age of 34 years (15 to 72) and mean delay
to surgery of 28.7 months (3 to 240). The patients were divided
into an unstable group (A) and stable group (B) depending on the
pre-operative radiographs. Unstable nonunion was defined as a lateral
intrascaphoid angle >
45°, or a radiolunate angle >
10°. There were
34 cases in group A and 31 cases in group B. Bony union was achieved
in 30 patients (88.2%) in group A, and in 26 (83.9%) in group B
(p = 0.439). Comparison of the post-operative radiographs between
the two groups showed no significant differences in lateral intrascaphoid
angle (p = 0.657) and scaphoid length
(p = 0.670) and height (p = 0.193). The radiolunate angle was significantly
different
(p = 0.020) but the mean value in both groups was <
10°. Comparison
of the dorsiflexion and palmar flexion of movement of the wrist
and the mean Mayo wrist score at the final clinical visit in each
group showed no significant difference (p = 0.190, p = 0.587 and
p = 0.265, respectively). Cancellous bone graft and K-wire fixation
were effective in the treatment of stable and unstable scaphoid
nonunion. Cite this article:
The sternoclavicular joint (SCJ) is a pivotal
articulation in the linked system of the upper limb girdle, providing
load-bearing in compression while resisting displacement in tension
or distraction at the manubrium sterni. The SCJ and acromioclavicular
joint (ACJ) both have a small surface area of contact protected
by an intra-articular fibrocartilaginous disc and are supported
by strong extrinsic and intrinsic capsular ligaments. The function
of load-sharing in the upper limb by bulky periscapular and thoracobrachial
muscles is extremely important to the longevity of both joints.
Ligamentous and capsular laxity changes with age, exposing both
joints to greater strain, which may explain the rising incidence
of arthritis in both with age. The incidence of arthritis in the
SCJ is less than that in the ACJ, suggesting that the extrinsic
ligaments of the SCJ provide greater stability than the coracoclavicular
ligaments of the ACJ. Instability of the SCJ is rare and can be difficult to distinguish
from medial clavicular physeal or metaphyseal fracture-separation:
cross-sectional imaging is often required. The distinction is important
because the treatment options and outcomes of treatment are dissimilar,
whereas the treatment and outcomes of ACJ separation and fracture
of the lateral clavicle can be similar. Proper recognition and treatment
of traumatic instability is vital as these injuries may be life-threatening.
Instability of the SCJ does not always require surgical intervention.
An accurate diagnosis is required before surgery can be considered,
and we recommend the use of the Stanmore instability triangle. Most
poor outcomes result from a failure to recognise the underlying
pathology. There is a natural reluctance for orthopaedic surgeons to operate
in this area owing to unfamiliarity with, and the close proximity
of, the related vascular structures, but the interposed sternohyoid
and sternothyroid muscles are rarely injured and provide a clear
boundary to the medial retroclavicular space, as well as an anatomical
barrier to unsafe intervention. This review presents current concepts of instability of the SCJ,
describes the relevant surgical anatomy, provides a framework for
diagnosis and management, including physiotherapy, and discusses
the technical challenges of operative intervention. Cite this article:
In adults with brachial plexus injuries, lack
of active external rotation at the shoulder is one of the most common residual
deficits, significantly compromising upper limb function. There
is a paucity of evidence to address this complex issue. We present
our experience of isolated latissimus dorsi (LD) muscle transfer
to achieve active external rotation. This is a retrospective review
of 24 adult post-traumatic plexopathy patients who underwent isolated latissimus
dorsi muscle transfer to restore external rotation of the shoulder
between 1997 and 2010. All patients were male with a mean age of
34 years (21 to 57). All the patients underwent isolated LD muscle
transfer using a standard technique to correct external rotational
deficit. Outcome was assessed for improvement in active external rotation,
arc of movement, muscle strength and return to work. The mean improvement
in active external rotation from neutral was 24° (10° to 50°). The
mean increase in arc of rotation was 52° (38° to 55°). Mean power
of the external rotators was 3.5 Medical Research Council (MRC)
grades (2 to 5). A total of 21 patients (88%) were back in work by the time of
last follow up. Of these,
13 had returned to their pre-injury occupation. Isolated latissimus
dorsi muscle transfer provides a simple and reliable method of restoring
useful active external rotation in adults with brachial plexus injuries
with internal rotational deformity. Cite this article:
Lateral clavicular physeal injuries in adolescents
are frequently misinterpreted as acromioclavicular dislocations. There
are currently no clear guidelines for the management of these relatively
rare injuries. Non-operative treatment can result in a cosmetic
deformity, warranting resection of the non-remodelled original lateral
clavicle. However, fixation with Kirschner (K)-wires may be associated
with infection and/or prominent metalwork. We report our experience
with a small series of such cases. Between October 2008 and October 2011 five patients with lateral
clavicular physeal fractures (types III, IV and V) presented to
our unit. There were four boys and one girl with a mean age of 12.8
years (9 to 14). Four fractures were significantly displaced and
treated operatively using a tension band suture technique. One grade
III fracture was treated conservatively. The mean follow-up was
26 months (6 to 42). All patients made an uncomplicated recovery. The mean time to
discharge was three months. The QuickDASH score at follow-up was
0 for each patient. No patient developed subsequent growth disturbances. We advocate the surgical treatment of significantly displaced
Grade IV and V fractures to avoid cosmetic deformity. A tension
band suture technique avoids the problems of retained metalwork
and the need for a secondary procedure. Excellent clinical and radiological
results were seen in all our patients. Cite this article:
Instability after arthroplasty of the shoulder
is difficult to correct surgically. Soft-tissue procedures and revision surgery
using unconstrained anatomical components are associated with a
high rate of failure. The purpose of this study was to determine
the results of revision of an unstable anatomical shoulder arthroplasty
to a reverse design prosthesis. Between 2004 and 2007, 33 unstable
anatomical shoulder arthroplasties were revised to a reverse design.
The mean age of the patients was 71 years (53 to 86) and their mean
follow-up was 42 months (25 to 71). The mean time to revision was
26 months (4 to 164). Pain scores improved significantly (pre-operative
visual analogue scale (VAS) of 7.2 ( Cite this article:
Despite the expansion of arthroscopic surgery
of the shoulder, the open deltopectoral approach to the shoulder
is still frequently used, for example in fracture fixation and shoulder
replacement. However, it is sometimes accompanied by unexpected
bleeding. The cephalic vein is the landmark for the deltopectoral
interval, yet its intimate relationship with the deltoid artery,
and the anatomical variations in that structure, have not previously been
documented. In this study the vascular anatomy encountered during 100 consecutive
elective deltopectoral approaches was recorded and the common variants
described. Two common variants of the deltoid artery were encountered.
In type I (71%) it crosses the interval and tunnels into the deltoid
muscle without encountering the cephalic vein. However, in type
II (21%) it crosses the interval, reaches the cephalic vein and
then runs down, medial to and behind it, giving off several small
arterial branches that return back across the interval to the pectoralis
major. Several minor variations were also seen (8%). These variations in the deltoid artery have not previously been
described and may lead to confusion and unexpected bleeding during
this standard anterior surgical approach to the shoulder. Cite this article:
Surgical repair of posterosuperior rotator cuff
tears has a poorer outcome and a higher rate of failure compared
with repairs of supraspinatus tears. In this prospective cohort
study 28 consecutive patients with an irreparable posterosuperior
rotator cuff tear after failed conservative or surgical treatment
underwent teres major tendon transfer. Their mean age was 60 years
(48 to 71) and the mean follow-up was 25 months (12 to 80). The
mean active abduction improved from 79° (0° to 150°) pre-operatively
to 105° (20° to 180°) post-operatively (p = 0.011). The mean active
external rotation in 90° abduction improved from 25° (0° to 70°)
pre-operatively to 55° (0° to 90°) post-operatively (p <
0.001).
The mean Constant score improved from 43 (18 to 78) pre-operatively
to 65 (30 to 86) post-operatively (p <
0.001). The median post-operative
VAS (0 to 100) for pain decreased from 63 (0 to 96) pre-operatively to
5 (0 to 56) post-operatively (p <
0.001). In conclusion, teres major transfer effectively restores function
and relieves pain in patients with irreparable posterosuperior rotator
cuff tears and leads to an overall clinical improvement in a relatively
young and active patient group with limited treatment options. Cite this article:
This study provides recommendations on the position
of the implant in reverse shoulder replacement in order to minimise
scapular notching and osteophyte formation. Radiographs from 151
patients who underwent primary reverse shoulder replacement with
a single prosthesis were analysed at a mean follow-up of 28.3 months
(24 to 44) for notching, osteophytes, the position of the glenoid
baseplate, the overhang of the glenosphere, and the prosthesis scapular
neck angle (PSNA). A total of 20 patients (13.2%) had a notch (16 Grade 1 and four
Grade 2) and 47 (31.1%) had an osteophyte. In patients without either
notching or an osteophyte the baseplate was found to be positioned
lower on the glenoid, with greater overhang of the glenosphere and
a lower PSNA than those with notching and an osteophyte. Female patients
had a higher rate of notching than males (13.3% Based on these findings we make recommendations on the placement
of the implant in both male and female patients to avoid notching
and osteophyte formation. Cite this article:
Latissimus dorsi tendon transfer (LDTT) is technically
challenging. In order to clarify the local structural anatomy, we undertook
a morphometric study using six complete cadavers (12 shoulders).
Measurements were made from the tendon to the nearby neurovascular
structures with the arm in two positions: flexed and internally
rotated, and adducted in neutral rotation. The tendon was then transferred
and measurements were taken from the edge of the tendon to a reference
point on the humeral head in order to assess the effect of a novel
two-stage release on the excursion of the tendon. With the shoulder flexed and internally rotated, the mean distances
between the superior tendon edge and the radial nerve, brachial
artery, axillary nerve and posterior circumflex artery were 30 mm
(26 to 34), 28 mm (17 to 39), 21 mm (12 to 28) and 15 mm (10 to
21), respectively. The mean distance between the inferior tendon
edge and the radial nerve, brachial artery and profunda brachii
artery was 18 mm (8 to 27), 22 mm (15 to 32) and 14 mm (7 to 21), respectively.
Moving the arm to a neutral position reduced these distances. A
mean of 15 mm (8 to 21) was gained from a standard soft-tissue release,
and 32 mm (20 to 45) from an extensile release. These figures help to define further the structural anatomy of
this region and the potential for transfer of the latissimus dorsi
tendon. Cite this article:
The purpose of this study was to evaluate the
risk of late displacement after the treatment of distal radial fractures with
a locking volar plate, and to investigate the clinical and radiological
factors that might correlate with re-displacement. From March 2007
to October 2009, 120 of an original cohort of 132 female patients
with unstable fractures of the distal radius were treated with a
volar locking plate, and were studied over a follow-up period of
six months. In the immediate post-operative and final follow-up
radiographs, late displacement was evaluated as judged by ulnar
variance, radial inclination, and dorsal angulation. We also analysed
the correlation of a variety of clinical and radiological factors
with re-displacement. Ulnar variance was significantly overcorrected
(p <
0.001) while radial inclination and dorsal angulation were
undercorrected when compared statistically (p <
0.001) with the unaffected
side in the immediate post-operative stage. During follow-up, radial
shortening and dorsal angulation progressed statistically, but none
had a value beyond the acceptable range. Bone mineral density measured
at the proximal femur and the position of the screws in the subchondral
region, correlated with slight progressive radial shortening, which
was not clinically relevant. Volar locking plating of distal radial fractures is a reliable
form of treatment without substantial late displacement. Cite this article:
There have been only a few small studies of patients
with an infected shoulder replacement treated with a single-stage
exchange procedure. We retrospectively reviewed 35 patients (19 men
and 16 women) with a peri-prosthetic infection of the shoulder who
were treated in this way. A total of 26 were available for clinical
examination; three had died, two were lost to follow-up and four
patients had undergone revision surgery. The mean follow-up time was
4.7 years (1.1 to 13.25), with an infection-free survival of 94%. The organisms most commonly isolated intra-operatively were Single-stage exchange is a successful and practical treatment
for patients with peri-prosthetic infection of the shoulder. Cite this article:
Like athletes, musicians are vulnerable to musculoskeletal
injuries that can be career ending or have a severe negative financial
impact. All ages are affected, with a peak incidence in the third
and fourth decades. Women are slightly more likely to be affected
than men. It is incumbent upon orthopaedic surgeons to be able to
complete a thorough physical assessment, be aware of the risk factors
associated with musculoskeletal symptoms in musicians, and have
a detailed knowledge of the specific syndromes they suffer and their
appropriate treatment. In this paper we review the common hand injuries that afflict
musicians and discuss their treatment. Cite this article:
This study reports the clinical and sonographic
outcome of arthroscopic rotator cuff repair in patients aged ≥ 70 years
and aimed to determine factors associated with re-tear. A total
of 69 consecutive repairs were performed in 68 patients with a mean
age of 77 years (70 to 86). Constant-Murley scores were collected
pre-operatively and at one year post-operatively. The integrity
of the repair was assessed using ultrasound. Re-tear was detected
in 20 of 62 patients (32%) assessed with ultrasound. Age at operation We conclude that arthroscopic rotator cuff repair in patients
aged ≥ 70 years is a successful procedure. The gender and age of
the patient are important factors to consider when planning management. Cite this article:
We investigated the incidence of and risk factors
for venous thromboembolism (VTE) following surgery of the shoulder
and elbow and assessed the role of thromboprophylaxis in upper limb
surgery. All papers describing VTE after shoulder and elbow surgery
published in the English language literature before 31 March 2012
were reviewed. A total of 14 papers were available for analysis,
most of which were retrospective studies and case series. The incidence
of VTE was 0.038% from 92 440 shoulder arthroscopic procedures,
0.52% from 42 261 shoulder replacements, and 0.64% from 4833 procedures
for fractures of the proximal humerus (open reduction and internal fixation
or hemiarthroplasty). The incidence following replacement of the
elbow was 0.26% from 2701 procedures. Diabetes mellitus, rheumatoid
arthritis and ischaemic heart disease were identified as the major
risk factors. The evidence that exists on thromboprophylaxis is based on level
III and IV studies, and we therefore cannot make any recommendations
on prophylaxis based on the current evidence. It seems reasonable
to adopt a multimodal approach that involves all patients receiving
mechanical prophylaxis, with chemical prophylaxis reserved for those
who are at high risk for VTE. Cite this article:
Reverse total shoulder replacement (RTSR) depends
on adequate deltoid function for a successful outcome. However, the
anterior deltoid and/or axillary nerve may be damaged due to prior
procedures or injury. The purpose of this study was to determine
the compensatory muscle forces required for scapular plane elevation
following RTSR when the anterior deltoid is deficient. The soft
tissues were removed from six cadaver shoulders, except for tendon
attachments. After implantation of the RTSR, the shoulders were
mounted on a custom-made shoulder simulator to determine the mean
force in each muscle required to achieve 30° and 60° of scapular
plane elevation. Two conditions were tested: 1) Control with an
absent supraspinatus and infraspinatus; and 2) Control with anterior
deltoid deficiency. Anterior deltoid deficiency resulted in a mean
increase of 195% in subscapularis force at 30° when compared with
the control (p = 0.02). At 60°, the subscapularis force increased
a mean of 82% (p <
0.001) and the middle deltoid force increased
a mean of 26% (p = 0.04). Scapular plane elevation may still be possible following an RTSR
in the setting of anterior deltoid deficiency. When the anterior
deltoid is deficient, there is a compensatory increase in the force
required by the subscapularis and middle deltoid. Attempts to preserve
the subscapularis, if present, might maximise post-operative function.
The purpose of this study was to assess the clinical
and radiological outcomes of dorsal intercarpal ligament capsulodesis
for the treatment of static scapholunate instability at a minimum
follow-up of four years. A total of 59 patients who underwent capsulodesis
for this condition were included in a retrospective analysis after
a mean of 8.25 years (4.3 to 12). A total of eight patients underwent
a salvage procedure at a mean of 2.33 years (0.67 to 7.6) and were
excluded. The mean range of extension/flexion was 88° (15° to 135°)
and of ulnar/radial deviation was 38° (0° to 75°) at final follow-up.
The mean Disabilities of the Arm Shoulder and Hand (DASH) score
and Mayo wrist scores were 28 (0 to 85) and 61 (0 to 90), respectively Capsulodesis did not maintain carpal reduction over time. Although
the consequent ongoing scapholunate instability resulted in early
arthritic degeneration, most patients had acceptable long-term function
of the wrist.
The Motec cementless modular metal-on-metal ball-and-socket
wrist arthroplasty was implanted in 16 wrists with scaphoid nonunion
advanced collapse (SNAC; grades 3 or 4) and 14 wrists with scapholunate
advanced collapse (SLAC) in 30 patients (20 men) with severe (grades
3 or 4) post-traumatic osteoarthritis of the wrist. The mean age of
the patients was 52 years (31 to 71). All prostheses integrated
well radiologically. At a mean follow-up of 3.2 years (1.1 to 6.1)
no luxation or implant breakage occurred. Two wrists were converted
to an arthrodesis for persistent pain. Loosening occurred in one
further wrist at five years post-operatively. The remainder demonstrated close
bone–implant contact. The clinical results were good, with markedly
decreased Disabilities of the Arm Shoulder and Hand (DASH) and pain
scores, and increased movement and grip strength. No patient used
analgesics and most had returned to work. Good short-term function was achieved using this wrist arthroplasty
in a high-demand group of patients with post-traumatic osteoarthritis.
Bone loss involving articular surface is a challenging
problem faced by the orthopaedic surgeon. In the hand and wrist,
there are articular defects that are amenable to autograft reconstruction
when primary fixation is not possible. In this article, the surgical
techniques and clinical outcomes of articular reconstructions in
the hand and wrist using non-vascularised osteochondral autografts
are reviewed.
This study evaluates the position of the long
head of biceps tendon using ultrasound following simple tenotomy,
in patients with arthroscopically repaired rotator cuff tears. In total, 52 patients with a mean age of 60.7 years (45 to 75)
underwent arthroscopic repair of the rotator cuff and simple tenotomy
of the long head of biceps tendon. At two years post-operatively,
ultrasound revealed that the tendon was inside the bicipital groove
in 43 patients (82.7%) and outside in nine (17.3%); in six of these
it was lying just outside the groove and in the remaining three
(5.8%) it was in a remote position with a positive Popeye Sign.
A dynamic ultrasound scan revealed that the tenotomised tendons
had adhered to the surrounding tissues (autotenodesis).The initial
condition of the tendon influenced its final position (p <
0.0005).
The presence of a Popeye sign was statistically influenced by the
pre-operative co-existence of supraspinatus and subscapularis tears (p
<
0.0001). It appears that the natural history of the tenotomised long head
of biceps tendon is to tenodese itself inside or just outside the
bicipital groove, while its pre-operative condition and coexistent
subscapularis tears play a significant role in the occurrence of
a Popeye sign.
We systematically reviewed all the evidence published
in the English language on proximal interphalangeal joint (PIPJ)
replacement, to determine its effectiveness on the function of the
hand and the associated post-operative complications. Original studies were selected if they reported clinical outcome
with a minimum of one year’s follow-up. Quality was assessed using
the Cowley systematic review criteria modified for finger-joint
replacements. Of 319 articles identified, only five were adequately
reported according to our quality criteria; there were no randomised
controlled trials. PIPJ replacements had a substantial effect size
on hand pain of -23.2 (95% confidence interval (CI) -27.3 to -19.1)
and grip strength 1.2 (95% CI -10.7 to 13.1), and a small effect
on range of movement 0.2 (95% CI -0.4 to 0.8). A dorsal approach
was most successful. Post-operative loosening occurred in 10% (95%
CI 3 to 30) of ceramic and 12.5% (95% CI 7 to 21) of pyrocarbon
replacements. Post-operative complications occurred in 27.8% (95%
CI 20 to 37). We conclude that the effectiveness of PIPJ replacement has not
been established. Small observational case studies and short-term
follow-up, together with insufficient reporting of patient data,
functional outcomes and complications, limit the value of current
evidence. We recommend that a defined core set of patients, surgical and
outcome data for this intervention be routinely and systematically
collected within the framework of a joint registry.
Injectable collagenase is an alternative to surgical
treatment for Dupuytren’s disease. Previous studies have reported
on the effectiveness of collagenase in finger contractures. This
prospective study reports on the short-term safety and efficacy
of collagenase treatment in five thumb and first web space Dupuytren’s
contractures. The thumb and first web space contractures were treated
with injectable collagenase in four consecutive patients (five hands) with
experience of previous surgical digital fasciectomy. The thumb contracture
was measured by angle and span in two planes of thumb extension
and abduction before injection and after manipulation. Collagenase
treatment resulted in release of the contracture with a mean increase
in thumb to index angle from 23° (10° to 35°) to 56° (45° to 60°)
in extension and from 30° (10° to 50°) to 58° (50° to 65°) in abduction
and a mean increase in span from 1.9 cm (1 to 3.5) to 3.9 cm (3
to 5) in extension and from 2.4 cm (1.5 to 3.5) to 3.9 cm (3 to
4.5) in abduction. All patients reported an increased range of movement
and function and described collagenase therapy as preferable to
surgery. In the short-term collagenase is an effective, well-tolerated
and safe alternative to surgery for Dupuytren’s disease of the thumb.
There is little information about the management
of peri-prosthetic fracture of the humerus after total shoulder replacement
(TSR). This is a retrospective review of 22 patients who underwent
a revision of their original shoulder replacement for peri-prosthetic
fracture of the humerus with bone loss and/or loose components.
There were 20 women and two men with a mean age of 75 years (61
to 90) and a mean follow-up 42 months (12 to 91): 16 of these had
undergone a previous revision TSR. Of the 22 patients, 12 were treated
with a long-stemmed humeral component that bypassed the fracture.
All their fractures united after a mean of 27 weeks (13 to 94).
Eight patients underwent resection of the proximal humerus with
endoprosthetic replacement to the level of the fracture. Two patients
were managed with a clam-shell prosthesis that retained the original
components. The mean Oxford shoulder score (OSS) of the original
TSRs before peri-prosthetic fracture was 33 (14 to 48). The mean
OSS after revision for fracture was 25 (9 to 31). Kaplan-Meier survival
using re-intervention for any reason as the endpoint was 91% (95%
confidence interval (CI) 68 to 98) and 60% (95% CI 30 to 80) at
one and five years, respectively. There were two revisions for dislocation of the humeral head,
one open reduction for modular humeral component dissociation, one
internal fixation for nonunion, one trimming of a prominent screw
and one re-cementation for aseptic loosening complicated by infection,
ultimately requiring excision arthroplasty. Two patients sustained
nerve palsies. Revision TSR after a peri-prosthetic humeral fracture associated
with bone loss and/or loose components is a salvage procedure that
can provide a stable platform for elbow and hand function. Good
rates of union can be achieved using a stem that bypasses the fracture.
There is a high rate of complications and function is not as good as
with the original replacement.
A total of 159 patients (84 women and 75 men,
mean age of 53 (20 to 87)) with subacromial impingement were randomised
to treatment with subacromial injections using lidocaine with one
of hyaluronic acid (51 patients), corticosteroid (53 patients) or
placebo (55 patients). Patients were followed up for 26 weeks. The
primary outcome was pain on a visual analogue score (VAS), and secondary
outcomes included the Constant Murley score, shoulder pain score,
functional mobility score, shoulder disability questionnaire and
pain-specific disability score. The different outcome measures showed
similar results. After three, six and 12 weeks corticosteroid injections
were superior to hyaluronic acid injections and only at six weeks
significantly better than placebo injections. The mean short-term
reduction in pain on the VAS score at 12 weeks was 7% ( We were not able to show a convincing benefit from hyaluronic
acid injections compared with corticosteroid or placebo injections.
Corticosteroid injections produced a significant reduction in pain
in the short term (three to 12 weeks), but in the long term the
placebo injection produced the best results.
The aim of this study was to determine whether there is any significant
difference in temporal measurements of pain, function and rates
of re-tear for arthroscopic rotator cuff repair (RCR) patients compared
with those patients undergoing open RCR. This study compared questionnaire- and clinical examination-based
outcomes over two years or longer for two series of patients who
met the inclusion criteria: 200 open RCR and 200 arthroscopic RCR
patients. All surgery was performed by a single surgeon. Objectives
Methods
Scapulothoracic fusion (STF) for painful winging
of the scapula in neuromuscular disorders can provide effective pain
relief and functional improvement, but there is little information
comparing outcomes between patients with dystrophic and non-dystrophic
conditions. We performed a retrospective review of 42 STFs in 34
patients with dystrophic and non-dystrophic conditions using a multifilament
trans-scapular, subcostal cable technique supported by a dorsal
one-third semi-tubular plate. There were 16 males and 18 females
with a mean age of 30 years (15 to 75) and a mean follow-up of 5.0
years (2.0 to 10.6). The mean Oxford shoulder score improved from
20 (4 to 39) to 31 (4 to 48). Patients with non-dystrophic conditions
had lower overall functional scores but achieved greater improvements
following STF. The mean active forward elevation increased from
59° (20° to 90°) to 97° (30° to 150°), and abduction from 51° (10°
to 90°) to 83° (30° to 130°) with a greater range of movement achieved
in the dystrophic group. Revision fusion for nonunion was undertaken
in five patients at a mean time of 17 months (7 to 31) and two required
revision for fracture. There were three pneumothoraces, two rib
fractures, three pleural effusions and six nonunions. The main risk
factors for nonunion were smoking, age and previous shoulder girdle surgery. STF is a salvage procedure that can provide good patient satisfaction
in 82% of patients with both dystrophic and non-dystrophic pathologies,
but there was a relatively high failure rate (26%) when poor outcomes
were analysed. Overall function was better in patients with dystrophic
conditions which correlated with better range of movement; however,
patients with non-dystrophic conditions achieved greater functional
improvement.
A total of 12 epileptic patients (14 shoulders)
with recurrent seizures and anterior dislocations of the shoulder underwent
a Latarjet procedure and were reviewed at a mean of 8.3 years (1
to 20) post-operatively. Mean forward flexion decreased from 165° (100° to 180°)
to 160° (90° to 180°) (p = 0.5) and mean external rotation from 54° (10° to 90°)
to 43° (5° to 75°) (p = 0.058). The mean Rowe score was 76 (35 to
100) at the final follow-up. Radiologically, all shoulders showed
a glenoid-rim defect and Hill-Sachs lesions pre-operatively. Osteo-arthritic changes
of the glenohumeral joint were observed in five shoulders (36%)
pre-operatively and in eight shoulders (57%) post-operatively.
Re-dislocation during a seizure occurred in six shoulders (43%).
Five of these patients underwent revision surgery using a bone buttress
from the iliac crest and two of these patients re-dislocated due
to a new seizure. Due to the unacceptably high rate of re-dislocation after surgery
in these patients, the most important means of reducing the incidence
of further dislocation is the medical management of the seizures.
The Latarjet procedure should be reserved for the well-controlled
patient with epilepsy who has recurrent anterior dislocation of
the shoulder during activities of daily living.
Follow-up radiographs are usually used as the
reference standard for the diagnosis of suspected scaphoid fractures. However,
these are prone to errors in interpretation. We performed a meta-analysis
of 30 clinical studies on the diagnosis of suspected scaphoid fractures,
in which agreement data between any of follow-up radiographs, bone scintigraphy,
magnetic resonance (MR) imaging, or CT could be obtained, and combined
this with latent class analysis to infer the accuracy of these tests
on the diagnosis of suspected scaphoid fractures in the absence
of an established standard. The estimated sensitivity and specificity
were respectively 91.1% and 99.8% for follow-up radiographs, 97.8%
and 93.5% for bone scintigraphy, 97.7% and 99.8% for MRI, and 85.2%
and 99.5% for CT. The results were generally robust in multiple
sensitivity analyses. There was large between-study heterogeneity
for the sensitivity of follow-up radiographs and CT, and imprecision
about their sensitivity estimates. If we acknowledge the lack of a reference standard for diagnosing
suspected scaphoid fractures, MRI is the most accurate test; follow-up
radiographs and CT may be less sensitive, and bone scintigraphy
less specific.
Local corticosteroid infiltration is a common practice of treatment
for lateral epicondylitis. In recent studies no statistically significant
or clinically relevant results in favour of corticosteroid injections
were found. The injection of autologous blood has been reported
to be effective for both intermediate and long-term outcomes. It
is hypothesised that blood contains growth factors, which induce
the healing cascade. A total of 60 patients were included in this prospective randomised
study: 30 patients received 2 ml autologous blood drawn from contralateral
upper limb vein + 1 ml 0.5% bupivacaine, and 30 patients received
2 ml local corticosteroid + 1 ml 0.5% bupivacaine at the lateral
epicondyle. Outcome was measured using a pain score and Nirschl
staging of lateral epicondylitis. Follow-up was continued for total
of six months, with assessment at one week, four weeks, 12 weeks
and six months.Objectives
Methods
A total of 92 patients with symptoms for over
six months due to subacromial impingement of the shoulder, who were
being treated with physiotherapy, were included in this study. While
continuing with physiotherapy they waited a further six months for
surgery. They were divided into three groups based on the following
four clinical and radiological criteria: temporary benefit following
steroid injection, pain in the mid-arc of abduction, a consistently positive
Hawkins test and radiological evidence of impingement. Group A fulfilled
all four criteria, group B three criteria and group C two criteria.
A total of nine patients improved while waiting for surgery and
were excluded, leaving 83 who underwent arthroscopic subacromial
decompression (SAD). The new Oxford shoulder score was recorded
pre-operatively and at three and 12 months post-operatively. A total of 51 patients (group A) had a significant improvement
in the mean shoulder score from 18 (13 to 22) pre-operatively to
38 (35 to 42) at three months (p <
0.001). The mean score in
this group was significantly better than in group B (21 patients)
and C (11 patients) at this time. At one year patients in all groups
showed improvement in scores, but patients in group A had a higher
mean score (p = 0.01). At one year patients in groups A and B did
better than those in group C (p = 0.01). Arthroscopic SAD is a beneficial intervention in selected patients.
The four criteria could help identify patients in whom it is likely
to be most effective.
Malunion is the most common complication of the
distal radius with many modalities of treatment available for such
a problem. The use of bone grafting after an osteotomy is still
recommended by most authors. We hypothesised that bone grafting
is not required; fixing the corrected construct with a volar locked
plate helps maintain the alignment, while metaphyseal defect fills
by itself. Prospectively, we performed the procedure on 30 malunited
dorsally-angulated radii using fixed angle volar locked plates without
bone grafting. At the final follow-up, 22 wrists were available.
Radiological evidence of union, correction of the deformity, clinical
and functional improvement was achieved in all cases. Without the
use of bone grafting, corrective open wedge osteotomy fixed by a
volar locked plate provides a high rate of union and satisfactory
functional outcomes.
We present the electromyographic (EMG) results
ten years after open decompression of the median nerve at the wrist
and compare them with the clinical and functional outcomes as judged
by Levine’s Questionnaire. This retrospective study evaluated 115
patients who had undergone carpal tunnel decompression at a mean
of 10.47 years (9.24 to 11.36) previously. A positive EMG diagnosis
was found in 77 patients (67%), including those who were asymptomatic
at ten years. It is necessary to include both clinical and functional results
as well as electromyographic testing in the long-term evaluation
of patients who have undergone carpal tunnel decompression particularly
in those in whom revision surgery is being considered. In doubtful
cases or when there are differing outcomes, self-administered scales
such as Levine’s Questionnaire should prevail over EMG results when
deciding on the need for revision surgery.
The pathogenesis of rotator cuff disease (RCD) is complex and
not fully understood. This systematic review set out to summarise
the histological and molecular changes that occur throughout the
spectrum of RCD. We conducted a systematic review of the scientific literature
with specific inclusion and exclusion criteria.Introduction
Methods
Dislocation of the shoulder may occur during
seizures in epileptics and other patients who have convulsions. Following
the initial injury, recurrent instability is common owing to a tendency
to develop large bony abnormalities of the humeral head and glenoid
and a susceptibility to further seizures. Assessment is difficult
and diagnosis may be missed, resulting in chronic locked dislocations
with protracted morbidity. Many patients have medical comorbidities,
and successful treatment requires a multidisciplinary approach addressing
the underlying seizure disorder in addition to the shoulder pathology.
The use of bony augmentation procedures may have improved the outcomes
after surgical intervention, but currently there is no evidence-based
consensus to guide treatment. This review outlines the epidemiology
and pathoanatomy of seizure-related instability, summarising the
currently-favoured options for treatment, and their results.
Diabetes mellitus is recognised as a risk factor
for carpal tunnel syndrome. The response to treatment is unclear,
and may be poorer than in non-diabetic patients. Previous randomised
studies of interventions for carpal tunnel syndrome have specifically
excluded diabetic patients. The aim of this study was to investigate
the epidemiology of carpal tunnel syndrome in diabetic patients,
and compare the outcome of carpal tunnel decompression with non-diabetic
patients. The primary endpoint was improvement in the QuickDASH
score. The prevalence of diabetes mellitus was 11.3% (176 of 1564).
Diabetic patients were more likely to have severe neurophysiological
findings at presentation. Patients with diabetes had poorer QuickDASH
scores at one year post-operatively (p = 0.028), although the mean
difference was lower than the minimal clinically important difference
for this score. After controlling for underlying differences in
age and gender, there was no difference between groups in the magnitude of
improvement after decompression (p = 0.481). Patients with diabetes
mellitus can therefore be expected to enjoy a similar improvement
in function.
We reviewed 101 patients with injuries of the
terminal branches of the infraclavicular brachial plexus sustained between
1997 and 2009. Four patterns of injury were identified: 1) anterior
glenohumeral dislocation (n = 55), in which the axillary and ulnar
nerves were most commonly injured, but the axillary nerve was ruptured
in only two patients (3.6%); 2) axillary nerve injury, with or without
injury to other nerves, in the absence of dislocation of the shoulder
(n = 20): these had a similar pattern of nerve involvement to those
with a known dislocation, but the axillary nerve was ruptured in
14 patients (70%); 3) displaced proximal humeral fracture (n = 15),
in which nerve injury resulted from medial displacement of the humeral
shaft: the fracture was surgically reduced in 13 patients; and 4) hyperextension
of the arm (n = 11): these were characterised by disruption of the
musculocutaneous nerve. There was variable involvement of the median
and radial nerves with the ulnar nerve being least affected. Surgical intervention is not needed in most cases of infraclavicular
injury associated with dislocation of the shoulder. Early exploration
of the nerves should be considered in patients with an axillary
nerve palsy without dislocation of the shoulder and for musculocutaneous
nerve palsy with median and/or radial nerve palsy. Urgent operation
is needed in cases of nerve injury resulting from fracture of the
humeral neck to relieve pressure on nerves.
We assessed the short- to mid-term survival of
metallic press-fit radial head prostheses in patients with radial
head fractures and acute traumatic instability of the elbow. The medical records of 42 patients (16 males, 26 females) with
a mean age of 56 years (23 to 85) with acute unstable elbow injuries,
including a fracture of the radial head requiring metallic replacement
of the radial head, were reviewed retrospectively. Survival of the
prosthesis was assessed from the radiographs of 37 patients after
a mean follow-up of 50 months (12 to 107). The functional results
of 31 patients were assessed using range-of-movement, Mayo elbow
performance score (MEPS), Disabilities of the Arm, Shoulder and
Hand (DASH) score and the RAND 36-item health survey. At the most recent follow-up 25 prostheses were still well fixed,
nine had been removed because of loosening, and three remained implanted
but were loose. The mean time from implantation to loosening was
11 months (2 to 24). Radiolucent lines that developed around the
prosthesis before removal were mild in three patients, moderate
in one and severe in five. Range of movement parameters and mass
grip strength were significantly lower in the affected elbow than
in the unaffected side. The mean MEPS score was 86 (40 to 100) and
the mean DASH score was 23 (0 to 81). According to RAND-36 scores,
patients had more pain and lower physical function scores than normal population
values. Loosening of press-fit radial head prostheses is common, occurs
early, often leads to severe osteolysis of the proximal radius,
and commonly requires removal of the prosthesis.
The outcome of an anatomical shoulder replacement
depends on an intact rotator cuff. In 1981 Grammont designed a novel
large-head reverse shoulder replacement for patients with cuff deficiency.
Such has been the success of this replacement that it has led to
a rapid expansion of the indications. We performed a systematic
review of the literature to evaluate the functional outcome of each
indication for the reverse shoulder replacement. Secondary outcome
measures of range of movement, pain scores and complication rates
are also presented.
The aim of this study was to compare a third-generation
cementing procedure for glenoid components with a new technique
for cement pressurisation. In 20 pairs of scapulae, 20 keeled and
20 pegged glenoid components were implanted using either a third-generation
cementing technique (group 1) or a new pressuriser (group 2). Cement penetration
was measured by three-dimensional (3D) analysis of micro-CT scans.
The mean 3D depth of penetration of the cement was significantly
greater in group 2 (p <
0.001). The mean thickness of the cement
mantle for keeled glenoids was 2.50 mm (2.0 to 3.3) in group 1 and
5.18 mm (4.4 to 6.1) in group 2, and for pegged glenoids it was 1.72 mm
(0.9 to 2.3) in group 1 and 5.63 mm (3.6 to 6.4) in group 2. A cement
mantle <
2 mm was detected less frequently in group 2 (p <
0.001). Using the cement pressuriser the proportion of cement mantles
<
2 mm was significantly reduced compared with the third-generation
cementing technique.
Cadaveric models of the shoulder evaluate discrete motion segments
using the glenohumeral joint in isolation over a defined trajectory.
The aim of this study was to design, manufacture and validate a
robotic system to accurately create three-dimensional movement of
the upper body and capture it using high-speed motion cameras. In particular, we intended to use the robotic system to simulate
the normal throwing motion in an intact cadaver. The robotic system
consists of a lower frame (to move the torso) and an upper frame
(to move an arm) using seven actuators. The actuators accurately
reproduced planned trajectories. The marker setup used for motion
capture was able to determine the six degrees of freedom of all
involved joints during the planned motion of the end effector.Objectives
Methods
We describe a new surgical technique for the
treatment of lacerations of the extensor tendon in zone I, which involves
a tenodesis using a length of palmaris longus tendon one-quarter
of its width. After exposing the dorsal aspect of the distal interphalangeal
joint and harvesting the tendon, a 1.5 mm drill bit is passed through
the insertion of the extensor tendon into the distal phalanx where
it penetrates through the skin of the pulp of the digit. The palmaris
longus tendon is threaded through the drill hole from dorsal to
ventral and the ventral end is tied in a simple knot and trimmed.
The palmaris longus tendon is then sutured to the extensor tendon
close to its insertion, and also at the middle of the middle phalanx. The operation was undertaken on 67 patients: 27 with an acute
injury and 40 patients with a chronic mallet deformity. One finger
(or the thumb) was involved in each patient. At a mean follow-up
of 12 months (6 to 18), 66 patients (98.5%) received excellent or
good results according to both the American Society for Surgery
of the Hand (ASSH) classification and Miller’s classification. Tenodesis using palmaris longus tendon after complete division
of an extensor tendon in zone 1 is a reliable form of treatment
for isolated acute or chronic ruptures.
The zona conoidea comprises the area of the lateral
trochlear ridge of the humerus. The purpose of this study is to reintroduce
this term ‘zona conoidea’ to the discussion of the human elbow and
to investigate its significance in the development of osteoarthritis
of the elbow. The upper extremities of 12 cadavers were prepared. With the
forearm in neutral, pronation and supination, the distance between
the bevel of the radial head and zona conoidea was inspected. A
total of 12 healthy volunteers had a CT scan. The distance between
the zona conoidea and the bevelled rim of the radial head was measured
in these positions. In the anatomical specimens, early osteo-arthritic changes were
identified in the posteromedial bevelled rim of the radial head,
and the corresponding zona conoidea in supination. Measurement in
the CT study showed that in full supination, the distance between
the bevel of the radial head and the zona conoidea was at a minimum. This study suggests that the significant contact between the
bevel of the radial head and the zona conoidea in supination is
associated with the initiation of osteoarthritis of the elbow in
this area.
The use of passive stretching of the elbow after
arthrolysis is controversial. We report the results of open arthrolysis in
81 patients. Prospectively collected outcome data with a minimum
follow-up of one year were analysed. All patients had sustained
an intra-articular fracture initially and all procedures were performed
by the same surgeon under continuous brachial plexus block anaesthesia
and with continuous passive movement (CPM) used post-operatively
for two to three days. CPM was used to maintain the movement achieved
during surgery and passive stretching was not used at any time.
A senior physiotherapist assessed all the patients at regular intervals.
The mean range of movement (ROM) improved from 69° to 109° and the
function and pain of the upper limb improved from 32 to 16 and from
20 to 10, as assessed by the Disabilities of the Arm Shoulder and
Hand score and a visual analogue scale, respectively. The greatest
improvement was obtained in the stiffest elbows: nine patients with
a pre-operative ROM <
30° achieved a mean post-operative ROM
of 92° (55° to 125°). This study demonstrates that in patients with
a stiff elbow after injury, good results may be obtained after open
elbow arthrolysis without using passive stretching during rehabilitation.
We investigated the clinical response to arthroscopic
synovectomy in patients with undifferentiated chronic monoarthritis
(UCMA) of the wrist. Arthroscopic synovectomy was performed on 20
wrists in 20 patients with UCMA of the wrist who had not responded
to non-steroidal anti-inflammatory drugs. The mean duration of symptoms
at the time of surgery was 4.3 months (3 to 7) and the mean follow-up
was 51.8 months (24 to 94). Inflamed synovium was completely removed
from the radiocarpal, midcarpal and distal radioulnar joints using
more portals than normal. After surgery, nine patients had early
remission of synovitis and 11 with uncontrolled synovitis received
antirheumatic medication. Overall, there was significant improvement
in terms of pain relief, range of movement and Mayo score. Radiological
deterioration was seen in five patients who were diagnosed as having rheumatoid
arthritis during the follow-up period. Lymphoid follicles and severe
lymphocyte infiltration were seen more often in synovial biopsies
from patients with uncontrolled synovitis. These results suggest that arthroscopic synovectomy provides
pain relief and functional improvement, and allows rapid resolution
of synovitis in about half of patients with UCMA of the wrist.
Radial osteotomy is currently advocated for patients
with Lichtman’s stages II and IIIA of Kienböck’s disease; its place
in the treatment of patients with stage IIIB disease remains controversial.
The purpose of this study was to evaluate the medium-term results
of this procedure and to compare the outcome in patients with stage
IIIB disease and those with earlier stages (II and IIIA). A total
of 18 patients (18 osteotomies) were evaluated both clinically and radiologically
at a mean follow-up of 10.3 years (4 to 18). Range of movement,
grip strength and pain improved significantly in all patients; the
functional score (Nakamura Scoring System (NSSK)) was high and self-reported disability
(Disabilities of Arm, Shoulder and Hand questionnaire) was low at
the final follow-up in all patients evaluated. Patients with stage
IIIB disease, however, had a significantly lower grip strength,
lower NSSK scores and higher disability than those in less advanced
stages. Radiological progression of the disease was not noted in
either group, despite the stage. Radial osteotomy seems effective
in halting the progression of disease and improving symptoms in
stages II, IIIA and IIIB. Patients with less advanced disease should
be expected to have better clinical results.
We report the effectiveness of revision of total
elbow replacement by re-cementing. Between 1982 and 2004, 53 elbows
in 52 patients were treated with re-cementing of a total elbow replacement
into part or all of the existing cement mantle or into the debrided
host-bone interface, without the use of structural bone augmentation
or a custom prosthesis. The original implant revision was still
In light of the growing number of elderly osteopenic
patients with distal humeral fractures, we discuss the history of
their management and current trends. Under most circumstances operative
fixation and early mobilisation is the treatment of choice, as it
gives the best results. The relative indications for and results
of total elbow replacement
Frozen shoulder is commonly encountered in general
orthopaedic practice. It may arise spontaneously without an obvious
predisposing cause, or be associated with a variety of local or
systemic disorders. Diagnosis is based upon the recognition of the
characteristic features of the pain, and selective limitation of
passive external rotation. The macroscopic and histological features
of the capsular contracture are well-defined, but the underlying
pathological processes remain poorly understood. It may cause protracted
disability, and imposes a considerable burden on health service
resources. Most patients are still managed by physiotherapy in primary
care, and only the more refractory cases are referred for specialist
intervention. Targeted therapy is not possible and treatment remains predominantly
symptomatic. However, over the last ten years, more active interventions
that may shorten the clinical course, such as capsular distension
arthrography and arthroscopic capsular release, have become more popular. This review describes the clinical and pathological features
of frozen shoulder. We also outline the current treatment options,
review the published results and present our own treatment algorithm.
We undertook this study to determine the minimum
amount of coronoid necessary to stabilise an otherwise intact elbow
joint. Regan–Morrey types II and III, plus medial and lateral oblique
coronoid fractures, collectively termed type IV fractures, were
simulated in nine fresh cadavers. An electromagnetic tracking system
defined the three-dimensional stability of the ulna relative to
the humerus. The coronoid surface area accounts for 59% of the anterior articulation.
Alteration in valgus, internal and external rotation occurred only
with a type III coronoid fracture, accounting for 68% of the coronoid
and 40% of the entire articular surface. A type II fracture removed
42% of the coronoid articulation and 25% of the entire articular
surface but was associated with valgus and external rotational changes
only when the radial head was removed, thereby removing 67% of the
articular surface. We conclude that all type III fractures, as defined here, are
unstable, even with intact ligaments and a radial head. However,
a type II deficiency is stable unless the radial head is removed.
Our study suggests that isolated medial-oblique or lateral-oblique
fractures, and even a type II fracture with intact ligaments and
a functional radial head, can be clinically stable, which is consistent
with clinical observation.
This study investigated the anatomical relationship between the clavicle and its adjacent vascular structures, in order to define safe zones, in terms of distance and direction, for drilling of the clavicle during osteosynthesis using a plate and screws following a fracture. We used reconstructed three-dimensional CT arteriograms of the head, neck and shoulder region. The results have enabled us to divide the clavicle into three zones based on the proximity and relationship of the vascular structures adjacent to it. The results show that at the medial end of the clavicle the subclavian vessels are situated behind it, with the vein intimately related to it. In some scans the vein was opposed to the posterior cortex of the clavicle. At the middle one-third of the clavicle the artery and vein are a mean of 17.02 mm (5.4 to 26.8) and 12.45 mm (5 to 26.1) from the clavicle, respectively, and at a mean angle of 50° (12 to 80) and 70° (38 to 100), respectively, to the horizontal. At the lateral end of the clavicle the artery and vein are at mean distances of 63.4 mm (46.8 to 96.5) and 75.67 mm (50 to 109), respectively. An appreciation of the information gathered from this study will help minimise the risk of inadvertent iatrogenic vascular injury during plating of the clavicle.
Radiological changes and differences between cemented and uncemented components of Grammont reverse shoulder arthroplasties (DePuy) were analysed at a mean follow-up of 9.6 years (8 to 12). Of 122 reverse shoulder arthroplasties implanted in five shoulder centres between 1993 and 2000, a total of 68 (65 patients) were available for study. The indications for reversed shoulder arthroplasty were cuff tear arthropathy in 48 shoulders, revision of shoulder prostheses of various types in 11 and massive cuff tear in nine. The development of scapular notching, bony scapular spur formation, heterotopic ossification, glenoid and humeral radiolucencies, stem subsidence, radiological signs of stress shielding and resorption of the tuberosities were assessed on standardised true anteroposterior and axillary radiographs. A scapular notch was observed in 60 shoulders (88%) and was associated with the superolateral approach (p = 0.009). Glenoid radiolucency was present in 11 (16%), bony scapular spur and/or ossifications in 51 (75%), and subsidence of the stem and humeral radiolucency in more than three zones were present in three (8.8%) and in four (11.8%) of 34 cemented components, respectively, and in one (2.9%) and two (5.9%) of 34 uncemented components, respectively. Radiological signs of stress shielding were significantly more frequent with uncemented components (p <
0.001), as was resorption of the greater (p <
0.001) and lesser tuberosities (p = 0.009).
We evaluated the biomechanical properties of two different methods of fixation for unstable fractures of the proximal humerus. Biomechanical testing of the two groups, locking plate alone (LP), and locking plate with a fibular strut graft (LPSG), was performed using seven pairs of human cadaveric humeri. Cyclical loads between 10 N and 80 N at 5 Hz were applied for 1 000 000 cycles. Immediately after cycling, an increasing axial load was applied at a rate of displacement of 5 mm/min. The displacement of the construct, maximum failure load, stiffness and mode of failure were compared. The displacement was significantly less in the LPSG group than in the LP group (p = 0.031). All maximum failure loads and measures of stiffness in the LPSG group were significantly higher than those in the LP group (p = 0.024 and p = 0.035, respectively). In the LP group, varus collapse and plate bending were seen. In the LPSG group, the humeral head cut out and the fibular strut grafts fractured. No broken plates or screws were seen in either group. We conclude that strut graft augmentation significantly increases both the maximum failure load and the initial stiffness of this construct compared with a locking plate alone.
Ununited fractures of the scaphoid with extensive bone resorption are usually treated by bone grafting and internal fixation, using either an open or a minimally invasive technique. We studied the feasibility of percutaneous fixation without bone grafting in a consecutive series of 27 patients with established nonunion of an undisplaced fracture of the scaphoid and extensive local resorption of bone. They were treated by a single surgeon with rigid fixation alone, using a headless cannulated screw inserted through a volar percutaneous technique. Clinical examination, standard radiographs and CT confirmed that the fracture had united in all patients at a mean of 11.6 weeks (8 to 16), and that their functional scores had improved. We concluded that extensive resorption at the fracture site is not an absolute indication for bone grafting, and that percutaneous fixation alone will eventually produce healing of ununited undisplaced fractures of the scaphoid regardless of the size of the gap.
This study reports the application of a novel method for quantitatively determining differences in the mechanical properties of healthy and torn rotator cuff tissues. In order to overcome problems of stress risers at the grip-tendon interface that can obscure mechanical measurements of small tendons, we conducted our investigation using dynamic shear analysis. Rotator cuff tendon specimens were obtained from 100 patients during shoulder surgery. They included 82 differently sized tears and 18 matched controls. We subjected biopsy samples of 3 mm in diameter to oscillatory deformation under compression using dynamic shear analysis. The storage modulus (G’) was calculated as an indicator of mechanical integrity. Normal tendons had a significantly higher storage modulus than torn tendons, indicating that torn tendons are mechanically weaker than normal tendons (p = 0.003). Normal tendons had a significantly higher mean shear modulus than tendons with massive tears (p <
0.01). Dynamic shear analysis allows the determination of shear mechanical properties of small tissue specimens obtained intra-operatively that could not be studied by conventional methods of tensile testing. These methods could be employed to investigate other musculoskeletal tissues. This pilot study provides some insight into mechanisms that might contribute to the failure of repair surgery, and with future application could help direct the most appropriate treatment for specific rotator cuff tears.
A suspected fracture of the scaphoid remains difficult to manage despite advances in knowledge and imaging methods. Immobilisation and restriction of activities in a young and active patient must be balanced against the risks of nonunion associated with an undiagnosed and undertreated fracture of the scaphoid. The assessment of diagnostic tests for a suspected fracture of the scaphoid must take into account two important factors. First, the prevalence of true fractures among suspected fractures is low, which greatly reduces the probability that a positive test will correspond with a true fracture, as false positives are nearly as common as true positives. This situation is accounted for by Bayesian statistics. Secondly, there is no agreed reference standard for a true fracture, which necessitates the need for an alternative method of calculating diagnostic performance characteristics, based upon a statistical method which identifies clinical factors tending to associate (latent classes) in patients with a high probability of fracture. The most successful diagnostic test to date is MRI, but in low-prevalence situations the positive predictive value of MRI is only 88%, and new data have documented the potential for false positive scans. The best strategy for improving the diagnosis of true fractures among suspected fractures of the scaphoid may well be to develop a clinical prediction rule incorporating a set of demographic and clinical factors which together increase the pre-test probability of a fracture of the scaphoid, in addition to developing increasingly sophisticated radiological tests.
Impingement syndrome in the shoulder has generally been considered to be a clinical condition of mechanical origin. However, anomalies exist between the pathology in the subacromial space and the degree of pain experienced. These may be explained by variations in the processing of nociceptive inputs between different patients. We investigated the evidence for augmented pain transmission (central sensitisation) in patients with impingement, and the relationship between pre-operative central sensitisation and the outcomes following arthroscopic subacromial decompression. We recruited 17 patients with unilateral impingement of the shoulder and 17 age- and gender-matched controls, all of whom underwent quantitative sensory testing to detect thresholds for mechanical stimuli, distinctions between sharp and blunt punctate stimuli, and heat pain. Additionally Oxford shoulder scores to assess pain and function, and PainDETECT questionnaires to identify ‘neuropathic’ and referred symptoms were completed. Patients completed these questionnaires pre-operatively and three months post-operatively. A significant proportion of patients awaiting subacromial decompression had referred pain radiating down the arm and had significant hyperalgesia to punctate stimulus of the skin compared with controls (unpaired The presence of either hyperalgesia or referred pain pre-operatively resulted in a significantly worse outcome from decompression three months after surgery (unpaired These observations confirm the presence of central sensitisation in a proportion of patients with shoulder pain associated with impingement. Also, if patients had relatively high levels of central sensitisation pre-operatively, as indicated by higher levels of punctate hyperalgesia and/or referred pain, the outcome three months after subacromial decompression was significantly worse.
The transfer of part of the ulnar nerve to the musculocutaneous nerve, first described by Oberlin, can restore flexion of the elbow following brachial plexus injury. In this study we evaluated the additional benefits and effectiveness of quantitative electrodiagnosis to select a donor fascicle. Eight patients who had undergone transfer of a simple fascicle of the ulnar nerve to the motor branch of the musculocutaneous nerve were evaluated. In two early patients electrodiagnosis had not been used. In the remaining six patients, however, all fascicles of the ulnar nerve were separated and electrodiagnosis was performed after stimulation with a commercially available electromyographic system. In these procedures, recording electrodes were placed in flexor carpi ulnaris and the first dorsal interosseous. A single fascicle in the flexor carpi ulnaris in which a high amplitude had been recorded was selected as a donor and transferred to the musculocutaneous nerve. In the two patients who had not undergone electrodiagnosis, the recovery of biceps proved insufficient for normal use. Conversely, in the six patients in whom quantitative electrodiagnosis was used, elbow flexion recovered to an M4 level. Quantitative intra-operative electrodiagnosis is an effective method of selecting a favourable donor fascicle during the Oberlin procedure. Moreover, fascicles showing a high-amplitude in reading flexor carpi ulnaris are donor nerves that can restore normal elbow flexion without intrinsic loss.
We have used Fourier transform infrared spectroscopy (FTIR) to characterise the chemical and structural composition of the tendons of the rotator cuff and to identify structural differences among anatomically distinct tears. Such information may help to identify biomarkers of tears and to provide insight into the rates of healing of different sizes of tear. The infrared spectra of 81 partial, small, medium, large and massive tears were measured using FTIR and compared with 11 uninjured control tendons. All the spectra were classified using standard techniques of multivariate analysis. FTIR readily differentiates between normal and torn tendons, and different sizes of tear. We identified the key discriminating molecules and spectra altered in torn tendons to be carbohydrates/phospholipids (1030 cm−1 to 1200 cm−1), collagen (1300 cm−1 to 1700 cm−1 and 3000 cm−1 to 3350 cm−1) and lipids (2800 cm−1 to 3000 cm−1). Our study has shown that FTIR spectroscopy can identify tears of the rotator cuff of varying size based upon distinguishable chemical and structural features. The onset of a tear is mainly associated with altered structural arrangements of collagen, with changes in lipids and carbohydrates. The approach described is rapid and has the potential to be used peri-operatively to determine the quality of the tendon and the extent of the disease, thus guiding surgical repair.
Mason type III fractures of the radial head are treated by open reduction and internal fixation, resection or prosthetic joint replacement. When internal fixation is performed, fixation of the radial head to the shaft is difficult and implant-related complications are common. Furthermore, problems of devascularisation of the radial head can result from fixation of the plate to the radial neck. In a small retrospective study, the treatment of Mason type III fractures with fixation of the radial neck in 13 cases (group 2) was compared with 12 cases where no fixation was performed (group 1). The mean clinical and radiological follow-up was four years (1 to 9). The Broberg-Morrey index showed excellent results in both groups. Degenerative radiological changes were seen more frequently in group 2, and removal of the implant was necessary in seven of 13 cases. Post-operative evaluation of these two different techniques revealed similar ranges of movement and functional scores. We propose that anatomical reconstruction of the radial head without metalwork fixation to the neck is preferable, and the outcome is the same as that achieved with the conventional technique. In addition degenerative changes of the elbow joint may develop less frequently, and implant removal is not necessary.
We have reviewed 38 surgically treated cases of spontaneous posterior interosseous nerve palsy in 38 patients with a mean age of 43 years (13 to 68) in order to identify clinical factors associated with its prognosis. Interfascicular neurolysis was performed at a mean of 13 months (1 to 187) after the onset of symptoms. The mean follow-up was 21 months (5.5 to 221). Medical Research Council muscle power of more than grade 4 was considered to be a good result. A further 12 cases in ten patients were treated conservatively and assessed similarly. Of the 30 cases treated surgically with available outcome data, the result of interfascicular neurolysis was significantly better in patients <
50 years old (younger group (18 nerves); good: 13 nerves (72%), poor: five nerves (28%)) than in cases >
50 years old (older group (12 nerves); good: one nerve (8%), poor: 11 nerves (92%)) (p <
0.001). A pre-operative period of less than seven months was also associated with a good result in the younger group (p = 0.01). The older group had a poor result regardless of the pre-operative delay. Our recommended therapeutic approach therefore is to perform interfascicular neurolysis if the patient is <
50 years of age, and the pre-operative delay is <
seven months. If the patient is >
50 years of age with no sign of recovery for seven months, or in the younger group with a pre-operative delay of more than a year, we advise interfascicular neurolysis together with tendon transfer as the primary surgical procedure.
We report the long-term clinical and radiological outcomes of the Aequalis total shoulder replacement with a cemented all-polyethylene flat-back keeled glenoid component implanted for primary osteoarthritis between 1991 and 2003 in nine European centres. A total of 226 shoulders in 210 patients were retrospectively reviewed at a mean of 122.7 months (61 to 219) or at revision. Clinical outcome was assessed using the Constant score, patient satisfaction score and range of movement. Kaplan-Meier survivorship analysis was performed with glenoid revision for loosening and radiological glenoid loosening ( Younger patient age and the curettage technique for glenoid preparation correlated with loosening. The rate of glenoid revision and radiological loosening increased with duration of follow-up, but not until a follow-up of five years. Therefore, we recommend that future studies reporting radiological outcomes of new glenoid designs should report follow-up of at least five to ten years.
The integrity of the spinal accessory nerve is fundamental to thoracoscapular function and essential for scapulohumeral rhythm. This nerve is vulnerable along its superficial course. This study assessed the delay in diagnosis and referral for management of damage to this nerve, clarified its anatomical course and function, and documented the results of repair. From examination of our records, 111 patients with lesions of the spinal accessory nerve were treated between 1984 and 2007. In 89 patients (80.2%) the damage was iatropathic. Recognition and referral were seldom made by the surgeon responsible for the injury, leading to a marked delay in instituting treatment. Most referrals were made for painful loss of shoulder function. The clinical diagnosis is straightforward. There is a characteristic downward and lateral displacement of the scapula, with narrowing of the inferior scapulohumeral angle and loss of function, with pain commonly present. In all, 80 nerves were explored and 65 were repaired. The course of the spinal accessory nerve in relation to the sternocleidomastoid muscle was constant, with branches from the cervical plexus rarely conveying motor fibres. Damage to the nerve was predominantly posterior to this muscle. Despite the delay, the results of repair were surprising, with early relief of pain, implying a neuropathic source, which preceded generally good recovery of muscle function.
The combination of an irreparable tear of the rotator cuff and destructive arthritis of the shoulder joint may cause severe pain, disability and loss of independence in the aged. Standard anatomical shoulder replacements depend on a functioning rotator cuff, and hence may fail in the presence of tears in the cuff. Many designs of non-anatomical constrained or semi-constrained prostheses have been developed for cuff tear arthropathy, but have proved unsatisfactory and were abandoned. The DePuy Delta III reverse prosthesis, designed by Grammont, medialises and stabilises the centre of rotation of the shoulder joint and has shown early promise. This study evaluated the mid-term clinical and radiological results of this arthroplasty in a consecutive series of 50 shoulders in 43 patients with a painful pseudoparalysis due to an irreparable cuff tear and destructive arthritis, performed over a period of seven years by a single surgeon. A follow-up of 98% was achieved, with a mean duration of 39 months (8 to 81). The mean age of the patients at the time of surgery was 81 years (59 to 95). The female to male ratio was 5:1. During the seven years, six patients died of natural causes. The clinical outcome was assessed using the American Shoulder and Elbow score, the Oxford Shoulder Score and the Short-form 36 score. A radiological review was performed using the Sirveaux score for scapular notching. The mean American Shoulder and Elbow score was 19 (95% confidence interval (CI) 14 to 23) pre-operatively, and 65 (95% CI 48 to 82) (paired The mean maximum elevation improved from 55° pre-operatively to 105° at final follow-up. There were seven complications during the whole series, although only four patients required further surgery.
We describe the clinical outcome of a technique of surgical augmentation of chronic massive tears of the rotator cuff using a polyester ligament (Dacron) in 21 symptomatic patients (14 men, seven women) with a mean age of 66.5 years (55.0 to 85.0). All patients had MRI and arthroscopic evidence of chronic massive tears. The clinical outcome was assessed using the Constant and Murley and patient satisfaction scores at a mean follow-up of 36 months (30 to 46). The polyester ligament (500 mm × 10 mm) was passed into the joint via the portal of Neviaser, medial to the tear through healthy cuff. The two ends of the ligament holding the cuff were passed through tunnels made in the proximal humerus at the footprint of the insertion of the cuff. The ligament was tied with a triple knot over the humeral cortex. All the patients remained free from pain (p <
0.001) with improvement in function (p <
0.001) and range of movement (p <
0.001). The mean pre-operative and post-operative Constant scores were 46.7 (39.0 to 61.0) and 85.4 (52.0 to 96.0), respectively (p <
0.001). The mean patient satisfaction score was 90%. There were two failures, one due to a ruptured ligament after one year and the other due to deep-seated infection. The MR scan at the final follow-up confirmed intact and thickened bands in 15 of 17 patients. This technique of augmentation gives consistent relief from pain with improved shoulder movement in patients with symptomatic massive tears of the rotator cuff.
Total shoulder replacement is a successful procedure for degenerative or some inflammatory diseases of the shoulder. However, fixation of the glenoid seems to be the main weakness with a high rate of loosening. The results using all-polyethylene components have been better than those using metal-backed components. We describe our experience with 35 consecutive total shoulder replacements using a new metal-backed glenoid component with a mean follow-up of 75.4 months (48 to 154). Our implant differs from others because of its mechanism of fixation. It has a convex metal-backed bone interface and the main stabilising factor is a large hollow central peg. The patients were evaulated with standard radiographs and with the Constant Score, the Simple Shoulder Test and a visual analogue scale. All the scores improved and there was no loosening, no polyethylene-glenoid disassembly and no other implant-related complications. We conclude that a metal-backed glenoid component is a good option in total shoulder replacement with no worse results than of those using a cemented all-polyethylene prosthesis.
Fractures of the proximal humerus can lead to malalignment of the humeral head, necrosis and post-traumatic osteoarthritis. In such cases surface replacement might be a promising option. A total of 28 shoulders with glenohumeral arthritis subsequent to a fracture underwent surface replacement arthroplasty of the humeral head in patients with a mean age of 60 years (35 to 83). On the basis of the inclination of the impacted head, post-traumatic arthritis was divided into three types: type 1, an impacted fracture of the head in an anatomical position (seven cases); type 2, a valgus impacted fracture (13 cases); type 3, a varus impacted fracture (eight cases). The outcome was measured by means of the Constant score. According to the Boileau classification of the sequelae of fractures of the proximal humerus, all 28 patients had a final result of intra-capsular category 1. The mean Constant score for the 28 shoulders increased from 23.2 points (2 to 45) pre-operatively to 55.1 points (20 to 89) at a mean of 31 months (24 to 66) post-operatively. Valgus impacted fractures had significantly better results (p <
0.039). Surface replacement arthroplasty can provide good results for patients with post-traumatic osteoarthritis of the shoulder. Their use avoids post-operative complications of the humeral shaft, such as peri-prosthetic fractures. Further surgery can be undertaken more easily as the bone stock is preserved.
Between September 1993 and September 1996, we performed 34 Kudo 5 total elbow replacements in 31 rheumatoid patients. All 22 surviving patients were reviewed at a mean of 11.9 years (10 to 14). Their mean age was 56 years (37 to 78) at the time of operation. All had Larsen grade IV or V rheumatoid changes on X-ray. Nine (three bilateral replacements and six unilateral) had died from unrelated causes. One who had died before ten years underwent revision for dislocation. Of the 22 total elbow replacements reviewed six had required revision, four for aseptic loosening (one humeral and three ulnar) and two for infection. Post-operatively, one patient had neuropraxia of the ulnar nerve and one of the radial nerve. Two patients had valgus tilting of the ulnar component. With revision as the endpoint, the mean survival time for the prosthesis was 11.3 years (95% confidence interval (10 to 13) and the estimated survival of the prosthesis at 12 years according to Kaplan-Meier survival analysis was 74% (95% confidence interval 0.53 to 0.91). Of the 16 surviving implants, ten were free from pain, four had mild pain and two moderate. The mean arc of flexion/extension of the elbow was 106° (65° to 130°) with pronation/supination of 90° (30° to 150°) with the joint at 90° of flexion. The mean Mayo elbow performance score was 82 (60 to 100) with five excellent, ten good and one fair result. Good long-term results can be expected using the Kudo 5 total elbow replacement in patients with rheumatoid disease, with a low incidence of loosening of the components.
Between 1996 and 2008, nine patients with severe post-traumatic arthritis underwent revision of a failed interposition arthroplasty of the elbow with a further interposition procedure using an allograft of tendo Achillis at a mean of 5.6 years (0.7 to 13.1) after the initial procedure. There were eight men and one woman with a mean age of 47 years (36 to 56). The mean follow-up was 4.7 years (2 to 8). The mean Mayo Elbow Performance score improved from 49 (15 to 65) pre-operatively to 73 (55 to 95) (p = 0.04). The mean Disability of the Arm, Shoulder and Hand score was 26 (7 to 42). One patient was unavailable for clinical follow-up and one underwent total elbow replacement three months post-operatively. Of the remaining patients, one had an excellent, two had good, three fair and one a poor result. Subjectively, five of the nine patients were satisfied. Four continued manual labour. Revision interposition arthroplasty is an option for young, active patients with severe post-traumatic arthritis who require both mobility and durability of the elbow.
Linburg-Comstock syndrome is characterised by an anomalous tendon slip from the flexor pollicis longus to the flexor digitorum profundus, usually of the index finger. An incidence as high as 60% to 70% has been reported. Post-traumatic inflammation of inter-tendinous connections between the flexor pollicis longus and flexor digitorum profundus, usually of the index finger, may cause unexplained chronic pain in the distal forearm. A total of 11 patients (eight females, three males), mean age 29.1 years (14 to 47) with a clinical diagnosis of Linburg-Comstock syndrome underwent surgical release of the inter-tendinous connection. The mean follow-up was for 27 months (2 to 48). Ten patients reported excellent relief of pain in the forearm, with independent flexion of flexor pollicis longus and flexor digitorum profundus to the index finger. Surgical release was an effective treatment for the Linburg-Comstock syndrome in this series.
There are many types of treatment used to manage the frozen shoulder, but there is no consensus on how best to manage patients with this painful and debilitating condition. We conducted a review of the evidence of the effectiveness of interventions used to manage primary frozen shoulder using the Cochrane Database of Systematic Reviews, the Database of Abstracts of Reviews of Effects, the Physiotherapy Evidence Database, MEDLINE and EMBASE without language or date restrictions up to April 2009. Two authors independently applied selection criteria and assessed the quality of systematic reviews using the Assessment of Multiple Systematic Reviews (AMSTAR) tool. Data were synthesised narratively, with emphasis placed on assessing the quality of evidence. In total, 758 titles and abstracts were identified and screened, which resulted in the inclusion of 11 systematic reviews. Although these met most of the AMSTAR quality criteria, there was insufficient evidence to draw firm conclusions about the effectiveness of treatments commonly used to manage a frozen shoulder. This was mostly due to poor methodological quality and small sample size in primary studies included in the reviews. We found no reviews evaluating surgical interventions. More rigorous randomised trials are needed to evaluate the treatments used for frozen shoulder.
We compared the outcome of arthroscopic repair of the rotator cuff in 32 diabetic patients with the outcome in 32 non-diabetic patients matched for age, gender, size of tear and comorbidities. The Constant-Murley score improved from a mean of 49.2 (24 to 80) pre-operatively to 60.8 (34 to 95) post-operatively (p = 0.0006) in the diabetic patients, and from 46.4 (23 to 90) pre-operatively to 65.2 (25 to 100) post-operatively (p = 0.0003) in the non-diabetic patients at six months. This was significantly greater (p = 0.0002) in non-diabetic patients (18.8) than in diabetics (11.6). There was no significant change in the mean mental component of the Short-Form 12, but the mean physical component increased from 35 to 41 in non-diabetics (p = 0.0001), and from 37 to 39 (p = 0.15) in diabetics. These trends were observed at one year. Patients with diabetes showed improvement of pain and function following arthroscopic rotator cuff repair in the short term, but less than their non-diabetic counterparts.
We have compared the outcome of hemiarthroplasty of the shoulder in three distinct diagnostic groups, using survival analysis as used by the United Kingdom national joint registers, patient-reported outcome measures (PROMs) as recommended by Darzi in the 2008 NHS review, and transition and satisfaction questions. A total of 72 hemiarthroplasties, 19 for primary osteoarthritis (OA) with an intact rotator cuff, 22 for OA with a torn rotator cuff, and 31 for rheumatoid arthritis (RA), were followed up for between three and eight years. All the patients survived, with no revisions or dislocations and no significant radiological evidence of loosening. The mean new Oxford shoulder score (minimum/worst 0, maximum/best 48) improved significantly for all groups (p <
0.001), in the OA group with an intact rotator cuff from 21.4 to 38.8 (effect size 2.9), in the OA group with a torn rotator cuff from 13.3 to 27.2 (effect size 2.1) and in the RA group from 13.7 to 28.0 (effect size 3.1). By this assessment, and for the survival analysis, there was no significant difference between the groups. However, when ratings using the patient satisfaction questions were analysed, eight (29.6%) of the RA group were ‘disappointed’, compared with one (9.1%) of the OA group with cuff intact and one (7.7%) of the OA group with cuff torn. All patients in the OA group with cuff torn indicated that they would undergo the operation again, compared to ten (90.9%) in the OA group with cuff intact and 20 (76.9%) in the RA group. The use of revision rates alone does not fully represent outcome after hemiarthroplasty of the shoulder. Data from PROMs provides more information about change in pain and the ability to undertake activities and perform tasks. The additional use of satisfaction ratings shows that both the rates of revision surgery and PROMs need careful interpretation in the context of patient expectations.
Intraspinal re-implantation after traumatic avulsion of the brachial plexus is a relatively new technique. Three different approaches to the spinal cord have been described to date, namely the posterior scapular, anterolateral interscalenic multilevel oblique corpectomy and the pure lateral. We describe an anatomical study of the pure lateral approach, based on our clinical experience and studies on cadavers.
We have developed an illustrated questionnaire, the Hand20, comprising 20 short and easy-to-understand questions to assess disorders of the upper limb. We have examined the usefulness of this questionnaire by comparing reliability, validity, responsiveness and the level of missing data with those of the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire. A series of 431 patients with disorders of the upper limb completed the Hand20 and the Japanese version of the DASH (DASH-JSSH) questionnaire. The norms for Hand20 scores were determined in another cross-sectional study. Most patients had no difficulty in completing the Hand20 questionnaire, whereas the DASH-JSSH had a significantly higher rate of missing data. The standard score for the Hand20 was smaller than the reported norms for the DASH. Our study showed that the Hand20 questionnaire provided validation comparable with that of the DASH-JSSH. Explanatory illustrations and short questions which were easy-to-understand led to better rates of response and fewer missing data, even in elderly individuals with cognitive deterioration.
This study was performed to review the safety and outcome of total shoulder replacements in patients who are ≥ 80 years of age. A total of 50 total shoulder replacements in 44 patients at a mean age of 82 years (80 to 89) were studied. Their health and shoulder status, the operation and post-operative course were analysed, including pain, movement, patient satisfaction, medical and surgical complications, radiographs, the need for revision surgery, and implant and patient survival. A total of 27 patients had an ASA classification of III or IV and medical abnormalities were common. Of the 13 shoulders with bony deficiency of the glenoid, nine required grafting. The duration of hospital stay was prolonged and blood transfusions were common. There were no peri-operative deaths. The mean follow-up was for 5.5 years (2 to 12). Pain was significantly reduced (p <
0.001) and movement improved in active elevation and both external and internal rotation (p <
0.001). Using the Neer scale for assessing outcome, 40 (80%) shoulders had an excellent or satisfactory result. There were medical or surgical complications in 17 cases. Four shoulders developed radiological evidence of loosened glenoid components, and three of these had a poor outcome. Three other shoulders required revision, two for instability. By the time of this review 39 of the patients had died from unrelated causes at a mean of 7.5 years (0.8 to 16.4) after surgery. Total shoulder replacement is a relatively effective treatment in this elderly group of patients. However, there is a requirement for more intense patient care in the peri-operative period, and non-fatal medical or surgical complications are common. Most of these elderly patients will have a comfortable functional shoulder for the rest of their lives.
Displaced fractures of the lateral end of the clavicle in young patients have a high incidence of nonunion and a poor functional outcome after conservative management. Operative treatment is therefore usually recommended. However, current techniques may be associated with complications which require removal of the fixation device. We have evaluated the functional and radiological outcomes using a novel technique of open reduction and internal fixation. A series of 16 patients under 60 years of age with displaced fractures of the lateral end were treated by open reduction and fixation using a twin coracoclavicular endobutton technique. They were followed up for the first year after their injury. At one year the mean Constant score was 87.1 and the median Disabilities of the Arm, Shoulder and Hand score was 3.3. All fractures had united, except in one patient who developed an asymptomatic fibrous union. One patient had post-traumatic stiffness of the shoulder, which resolved with physiotherapy. None required re-operation. This technique produces good functional and radiological outcomes with a low prevalence of complications and routine implant removal is not necessary.
The outcome of surgery in patients with medial epicondylitis of the elbow is less favourable in those with co-existent symptoms from the ulnar nerve. We wanted to know whether we could successfully treat such patients by using musculofascial lengthening of the flexor-pronator origin with simultaneous deep transposition of the ulnar nerve. We retrospectively reviewed 19 patients who were treated in this way. Seven had grade I and 12 had grade IIa ulnar neuropathy. At a mean follow-up of 38 months (24 to 48), the mean visual analogue scale pain scores improved from 3.7 to 0.3 at rest, from 6.6 to 2.1 with activities of daily living, and from 7.9 to 2.3 at work or sports, and the mean disabilities of the arm, shoulder and hand scores improved from 42.2 to 23.5. These results suggest that this technique can be effective in treating patients with medial epicondylitis and coexistent ulnar nerve symptoms.