Advertisement for orthosearch.org.uk
Results 1 - 20 of 54
Results per page:
Bone & Joint Open
Vol. 3, Issue 8 | Pages 648 - 655
1 Aug 2022
Yeung CM Bhashyam AR Groot OQ Merchan N Newman ET Raskin KA Lozano-Calderón SA

Aims. Due to their radiolucency and favourable mechanical properties, carbon fibre nails may be a preferable alternative to titanium nails for oncology patients. We aim to compare the surgical characteristics and short-term results of patients who underwent intramedullary fixation with either a titanium or carbon fibre nail for pathological long-bone fracture. Methods. This single tertiary-institutional, retrospectively matched case-control study included 72 patients who underwent prophylactic or therapeutic fixation for pathological fracture of the humerus, femur, or tibia with either a titanium (control group, n = 36) or carbon fibre (case group, n = 36) intramedullary nail between 2016 to 2020. Patients were excluded if intramedullary fixation was combined with any other surgical procedure/fixation method. Outcomes included operating time, blood loss, fluoroscopic time, and complications. Fisher’s exact test and Mann-Whitney U test were used for categorical and continuous outcomes, respectively. Results. Patients receiving carbon nails as compared to those receiving titanium nails had higher blood loss (median 150 ml (interquartile range (IQR) 100 to 250) vs 100 ml (IQR 50 to 150); p = 0.042) and longer fluoroscopic time (median 150 seconds (IQR 114 to 182) vs 94 seconds (IQR 58 to 124); p = 0.001). Implant complications occurred in seven patients (19%) in the titanium group versus one patient (3%) in the carbon fibre group (p = 0.055). There were no notable differences between groups with regard to operating time, surgical wound infection, or survival. Conclusion. This pilot study demonstrates a non-inferior surgical and short-term clinical profile supporting further consideration of carbon fibre nails for pathological fracture fixation in orthopaedic oncology patients. Given enhanced accommodation of imaging methods important for oncological surveillance and radiation therapy planning, as well as high tolerances to fatigue stress, carbon fibre implants possess important oncological advantages over titanium implants that merit further prospective investigation. Level of evidence: III, Retrospective study. Cite this article: Bone Jt Open 2022;3(8):648–655


Aims. Our objective was to conduct a systematic review and meta-analysis, to establish whether differences arise in clinical outcomes between autologous and synthetic bone grafts in the operative management of tibial plateau fractures. Methods. A structured search of MEDLINE, EMBASE, the online archives of Bone & Joint Publishing, and CENTRAL databases from inception until 28 July 2021 was performed. Randomized, controlled, clinical trials that compared autologous and synthetic bone grafts in tibial plateau fractures were included. Preclinical studies, clinical studies in paediatric patients, pathological fractures, fracture nonunion, or chondral defects were excluded. Outcome data were assessed using the Risk of Bias 2 (ROB2) framework and synthesized in random-effect meta-analysis. The Preferred Reported Items for Systematic Review and Meta-Analyses guidance was followed throughout. Results. Six studies involving 353 fractures were identified from 3,078 records. Following ROB2 assessment, five studies (representing 338 fractures) were appropriate for meta-analysis. Primary outcomes showed non-significant reductions in articular depression at immediate postoperative (mean difference -0.45 mm, p = 0.25, 95%confidence interval (CI) -1.21 to 0.31, I. 2. = 0%) and long-term (> six months, standard mean difference -0.56, p = 0.09, 95% CI -1.20 to 0.08, I. 2. = 73%) follow-up in synthetic bone grafts. Secondary outcomes included mechanical alignment, limb functionality, and defect site pain at long-term follow-up, perioperative blood loss, duration of surgery, occurrence of surgical site infections, and secondary surgery. Mean blood loss was lower (90.08 ml, p < 0.001, 95% CI 41.49 to 138.67) and surgery was shorter (16.17 minutes, p = 0.04, 95% CI 0.39 to 31.94) in synthetic treatment groups. All other secondary measures were statistically comparable. Conclusion. All studies reported similar methodologies and patient populations; however, imprecision may have arisen through performance variation. These findings supersede previous literature and indicate that, despite perceived biological advantages, autologous bone grafting does not demonstrate superiority to synthetic grafts. When selecting a void filler, surgeons should consider patient comorbidity, environmental and societal factors in provision, and perioperative and postoperative care provision. Cite this article: Bone Jt Open 2022;3(3):218–228


Bone & Joint Open
Vol. 4, Issue 6 | Pages 442 - 446
12 Jun 2023
Toda Y Iwata S Kobayashi E Ogura K Osaki S Fukushima S Mawatari M Kawai A

Aims. The risk of postoperative complications after resection of soft-tissue sarcoma in the medial thigh is higher than in other locations. This study investigated whether a vessel sealing system (VSS) could help reduce the risk of postoperative complications after wide resection of soft-tissue sarcoma in the medial thigh. Methods. Of 285 patients who underwent wide resection for soft-tissue sarcoma between 2014 and 2021 at our institution, 78 patients with tumours in the medial thigh were extracted from our database. Information on clinicopathological characteristics, preoperative treatment, surgical treatment (use of VSS, blood loss volume, operating time), and postoperative course (complications, postoperative haemoglobin changes, total drainage volume, and drainage and hospitalization durations) were obtained from medical records. We statistically compared clinical outcomes between patients whose surgery did or did not use VSS (VSS and non-VSS groups, respectively). Results. There were 24 patients in the VSS group and 54 in the non-VSS group. There were no significant differences between the two groups in terms of clinicopathological background. The total drainage volume in the VSS group was significantly less than that in the non-VSS group (1,176 ml vs 3,114 ml; p = 0.018). Moreover, the drainage and hospitalization durations were significantly shorter in the VSS group compared to the non-VSS group (p = 0.017 and p = 0.024, respectively). Conclusion. Our results suggest that use of VSS can help reduce the risk of postoperative complications after wide resection of soft-tissue sarcoma in the medial thigh. Cite this article: Bone Jt Open 2023;4(6):442–446


Bone & Joint Open
Vol. 4, Issue 11 | Pages 899 - 905
24 Nov 2023
Orfanos G Nantha Kumar N Redfern D Burston B Banerjee R Thomas G

Aims. We aim to evaluate the usefulness of postoperative blood tests by investigating the incidence of abnormal results following total joint replacement (TJR), as well as identifying preoperative risk factors for abnormal blood test results postoperatively, especially pertaining to anaemia and acute kidney injury (AKI). Methods. This is a retrospective cohort study of patients who had elective TJR between January and December 2019 at a tertiary centre. Data gathered included age at time of surgery, sex, BMI, American Society of Anesthesiologists (ASA) grade, preoperative and postoperative laboratory test results, haemoglobin (Hgb), white blood count (WBC), haematocrit (Hct), platelets (Plts), sodium (Na. +. ), potassium (K. +. ), creatinine (Cr), estimated glomerular filtration rate (eGFR), and Ferritin (ug/l). Abnormal blood tests, AKI, electrolyte imbalance, anaemia, transfusion, reoperation, and readmission within one year were reported. Results. The study included 2,721 patients with a mean age of 69 years, of whom 1,266 (46.6%) were male. Abnormal postoperative bloods were identified in 444 (16.3%) patients. We identified age (≥ 65 years), female sex, and ASA grade ≥ III as risk factors for developing abnormal postoperative blood tests. Preoperative haemoglobin (≤ 127 g/dl) and packed cell volume (≤ 0.395 l/l) were noted to be significant risk factors for postoperative anaemia, and potassium (≤ 3.7 mmol/l) was noted to be a significant risk factor for AKI. Conclusion. The costs outweigh the benefits of ordering routine postoperative blood tests in TJR patients. Clinicians should risk-stratify their patients and have a lower threshold for ordering blood tests in patients with abnormal preoperative haemoglobin (≤ 127 g/l), blood loss > 300 ml, chronic kidney disease, ASA grade ≥ III, and clinical concern. Cite this article: Bone Jt Open 2023;4(11):899–905


Bone & Joint Open
Vol. 3, Issue 7 | Pages 536 - 542
11 Jul 2022
Karayiannis PN Agus A Bryce L Hill JC Beverland D

Aims. Tranexamic acid (TXA) is now commonly used in major surgical operations including orthopaedics. The TRAC-24 randomized control trial (RCT) aimed to assess if an additional 24 hours of TXA postoperatively in primary total hip (THA) and total knee arthroplasty (TKA) reduced blood loss. Contrary to other orthopaedic studies to date, this trial included high-risk patients. This paper presents the results of a cost analysis undertaken alongside this RCT. Methods. TRAC-24 was a prospective RCT on patients undergoing TKA and THA. Three groups were included: Group 1 received 1 g intravenous (IV) TXA perioperatively and an additional 24-hour postoperative oral regime, Group 2 received only the perioperative dose, and Group 3 did not receive TXA. Cost analysis was performed out to day 90. Results. Group 1 was associated with the lowest mean total costs, followed by Group 2 and then Group 3. The differences between Groups 1 and 3 (-£797.77 (95% confidence interval -1,478.22 to -117.32) were statistically significant. Extended oral dosing reduced costs for patients undergoing THA but not TKA. The reduced costs in Groups 1 and 2 resulted from reduced length of stay, readmission rates, emergency department attendances, and blood transfusions. Conclusion. This study demonstrated significant cost savings when using TXA in primary THA or TKA. Extended oral dosing reduced costs further in THA but not TKA. Cite this article: Bone Jt Open 2022;3(7):536–542


Bone & Joint Open
Vol. 5, Issue 10 | Pages 886 - 893
15 Oct 2024
Zhang C Li Y Wang G Sun J

Aims. A variety of surgical methods and strategies have been demonstrated for Andersson lesion (AL) therapy. In 2011, we proposed and identified the feasibility of stabilizing the spine without curettaging the vertebral or discovertebral lesion to cure non-kyphotic AL. Additionally, due to the excellent reunion ability of ankylosing spondylitis, we further came up with minimally invasive spinal surgery (MIS) to avoid the need for both bone graft and lesion curettage in AL surgery. However, there is a paucity of research into the comparison between open spinal fusion (OSF) and early MIS in the treatment of AL. The purpose of this study was to investigate and compare the clinical outcomes and radiological evaluation of our early MIS approach and OSF for AL. Methods. A total of 39 patients diagnosed with AL who underwent surgery from January 2004 to December 2022 were retrospectively screened for eligibility. Patients with AL were divided into an MIS group and an OSF group. The primary outcomes were union of the lesion on radiograph and CT, as well as the visual analogue scale (VAS) and Oswestry Disability Index (ODI) scores immediately after surgery, and at the follow-up (mean 29 months (standard error (SE) 9)). The secondary outcomes were total blood loss during surgery, operating time, and improvement in the radiological parameters: global and local kyphosis, sagittal vertical axis, sagittal alignment, and chin-brow vertical angle immediately after surgery and at the follow-up. Results. Data for 30 patients with AL were evaluated: 14 in the MIS group and 16 in the OSF group. All patients were followed up after surgery; no nonunion complications or instrumentation failures were observed in either group. No significant differences in the VAS and ODI scores were identified between the two groups. Mean ODI improved from 51 (SE 5) to 17 (SE 5) in the MIS group and from 52 (SE 6) to 19 (SE 5) in the OSF group at the follow-up. There were significant improvements in total blood loss (p = 0.025) and operating time (p < 0.001) between the groups. There was also no significant difference in local kyphosis six months postoperatively (p = 0.119). Conclusion. Early MIS is an effective treatment for AL. MIS provides comparable clinical outcomes to those treated with OSF, with less total blood loss and shorter operating time. Our results support and identify the feasibility of solid immobilization achieved by posterior instrumentation without bone graft via MIS for the treatment of AL. Cite this article: Bone Jt Open 2024;5(10):886–893


Bone & Joint Open
Vol. 5, Issue 9 | Pages 768 - 775
18 Sep 2024
Chen K Dong X Lu Y Zhang J Liu X Jia L Guo Y Chen X

Aims. Surgical approaches to cervical ossification of the posterior longitudinal ligament (OPLL) remain controversial. The purpose of the present study was to analyze and compare the long-term neurological recovery following anterior decompression with fusion (ADF) and posterior laminectomy and fusion with bone graft and internal fixation (PLF) based on > ten-year follow-up outcomes in a single centre. Methods. Included in this retrospective cohort study were 48 patients (12 females; mean age 55.79 years (SD 8.94)) who were diagnosed with cervical OPLL, received treatment in our centre, and were followed up for 10.22 to 15.25 years. Of them, 24 patients (six females; mean age 52.88 years (SD 8.79)) received ADF, and the other 24 patients (five females; mean age 56.25 years (SD 9.44)) received PLF. Clinical data including age, sex, and the OPLL canal-occupying ratio were analyzed and compared. The primary outcome was Japanese Orthopaedic Association (JOA) score, and the secondary outcome was visual analogue scale neck pain. Results. Compared with the baseline, neurological function improved significantly after surgery in all patients of both groups (p < 0.001). The JOA recovery rate in the ADF group was significantly higher than that in the PLF group (p < 0.001). There was no significant difference in postoperative cervical pain between the two groups (p = 0.387). The operating time was longer and intraoperative blood loss was greater in the PLF group than the ADF group. More complications were observed in the ADF group than in the PLF group, although the difference was not statistically significant. Conclusion. Long-term neurological function improved significantly after surgery in both groups, with the improvement more pronounced in the ADF group. There was no significant difference in postoperative neck pain between the two groups. The operating time was shorter and intraoperative blood loss was lower in the ADF group; however, the incidence of perioperative complications was higher. Cite this article: Bone Jt Open 2024;5(9):768–775


Bone & Joint Open
Vol. 3, Issue 1 | Pages 4 - 11
3 Jan 2022
Argyrou C Tzefronis D Sarantis M Kateros K Poultsides L Macheras GA

Aims. There is evidence that morbidly obese patients have more intra- and postoperative complications and poorer outcomes when undergoing total hip arthroplasty (THA) with the direct anterior approach (DAA). The aim of this study was to determine the efficacy of DAA for THA, and compare the complications and outcomes of morbidly obese patients with nonobese patients. Methods. Morbidly obese patients (n = 86), with BMI ≥ 40 kg/m. 2. who underwent DAA THA at our institution between September 2010 and December 2017, were matched to 172 patients with BMI < 30 kg/m. 2. Data regarding demographics, set-up and operating time, blood loss, radiological assessment, Harris Hip Score (HHS), International Hip Outcome Tool (12-items), reoperation rate, and complications at two years postoperatively were retrospectively analyzed. Results. No significant differences in blood loss, intra- and postoperative complications, or implant position were observed between the two groups. Superficial wound infection rate was higher in the obese group (8.1%) compared to the nonobese group (1.2%) (p = 0.007) and relative risk of reoperation was 2.59 (95% confidence interval 0.68 to 9.91). One periprosthetic joint infection was reported in the obese group. Set-up time in the operating table and mean operating time were higher in morbidly obese patients. Functional outcomes and patient-related outcome measurements were superior in the obese group (mean increase of HHS was 52.19 (SD 5.95) vs 45.1 (SD 4.42); p < 0.001), and mean increase of International Hip Outcome Tool (12-items) was 56.8 (SD 8.88) versus 55.2 (SD 5.85); p = 0.041). Conclusion. Our results suggest that THA in morbidly obese patients can be safely and effectively performed via the DAA by experienced surgeons. Cite this article: Bone Jt Open 2022;3(1):4–11


Bone & Joint Open
Vol. 5, Issue 4 | Pages 317 - 323
18 Apr 2024
Zhu X Hu J Lin J Song G Xu H Lu J Tang Q Wang J

Aims. The aim of this study was to investigate the safety and efficacy of 3D-printed modular prostheses in patients who underwent joint-sparing limb salvage surgery (JSLSS) for malignant femoral diaphyseal bone tumours. Methods. We retrospectively reviewed 17 patients (13 males and four females) with femoral diaphyseal tumours who underwent JSLSS in our hospital. Results. In all, 17 patients with locally aggressive bone tumours (Enneking stage IIB) located in the femoral shaft underwent JSLSS and reconstruction with 3D-printed modular prostheses between January 2020 and June 2022. The median surgical time was 153 minutes (interquartile range (IQR) 117 to 248), and the median estimated blood loss was 200ml (IQR 125 to 400). Osteosarcoma was the most common pathological type (n = 12; 70.6%). The mean osteotomy length was 197.53 mm (SD 12.34), and the median follow-up was 25 months (IQR 19 to 38). Two patients experienced local recurrence and three developed distant metastases. Postoperative complications included wound infection in one patient and screw loosening in another, both of which were treated successfully with revision surgery. The median Musculoskeletal Tumor Society score at the final follow-up was 28 (IQR 27 to 28). Conclusion. The 3D-printed modular prosthesis is a reliable and feasible reconstruction option for patients with malignant femoral diaphyseal tumours. It helps to improve the limb salvage rate, restore limb function, and achieve better short-term effectiveness. Cite this article: Bone Jt Open 2024;5(4):317–323


Bone & Joint Open
Vol. 2, Issue 4 | Pages 271 - 277
1 Apr 2021
Flatman M Barkham BH Ben David E Yeo A Norman J Gelfer Y

Aims. Open reduction in developmental dysplasia of the hip (DDH) is regularly performed despite screening programmes, due to failure of treatment or late presentation. A protocol for open reduction of DDH has been refined through collaboration between surgical, anaesthetic, and nursing teams to allow same day discharge. The objective of this study was to determine the safety and feasibility of performing open reduction of DDH as a day case. Methods. A prospectively collected departmental database was visited. All consecutive surgical cases of DDH between June 2015 and March 2020 were collected. Closed reductions, bilateral cases, cases requiring corrective osteotomy, and children with comorbidities were excluded. Data collected included demographics, safety outcome measures (blood loss, complications, readmission, reduction confirmation), and feasibility for discharge according to the Face Legs Activity Cry Consolidability (FLACC) pain scale. A satisfaction questionnaire was filled by the carers. Descriptive statistics were used for analysis. Results. Out of 168 consecutive DDH cases, 16 patients fit the inclusion criteria (age range 10 to 26 months, 13 female). Intraoperative blood loss ranged from "minimal" to 120 ml, and there were no complications or readmissions. The FLACC score was 0 for all patients. The carers satisfaction questionnaire expressed high satisfaction from the experience with adequate information and support provided. Conclusion. Open reduction in DDH, without corrective osteotomy, is safe and feasible to be managed as a day case procedure. It requires a clear treatment pathway, analgesia, sufficient counselling, and communication with carers. It is even more important during the COVID-19 pandemic when reduced length of hospital stay is likely to be safer for both patient and their parents. Cite this article: Bone Joint Open 2021;2(4):271–277


Bone & Joint Open
Vol. 2, Issue 2 | Pages 93 - 102
1 Feb 2021
Thompson JW Wignadasan W Ibrahim M Beasley L Konan S Plastow R Magan A Haddad FS

Aims. We present the development of a day-case total hip arthroplasty (THA) pathway in a UK National Health Service institution in conjunction with an extensive evidence-based summary of the interventions used to achieve successful day-case THA to which the protocol is founded upon. Methods. We performed a prospective audit of day-case THA in our institution as we reinitiate our full capacity elective services. In parallel, we performed a review of the literature reporting complication or readmission rates at ≥ 30-day postoperative following day-case THA. Electronic searches were performed using four databases from the date of inception to November 2020. Relevant studies were identified, data extracted, and qualitative synthesis performed. Results. Our evaluation and critique of the evidence-based literature identifies day-case THA to be safe, effective, and economical, benefiting both patients and healthcare systems alike. We further validate this with our institutional elective day surgery arthroplasty pathway (EDSAP) and report a small cohort of successful day-case THA cases as an example in the early stages of this practice in our unit. Conclusion. Careful patient selection and education, adequate perioperative considerations, including multimodal analgesia, surgical technique and blood loss management protocols and appropriate postoperative pathways comprising reliable discharge criteria are essential for successful day-case THA. Cite this article: Bone Jt Open 2021;2(2):93–102


Bone & Joint Open
Vol. 5, Issue 7 | Pages 560 - 564
7 Jul 2024
Meißner N Strahl A Rolvien T Halder AM Schrednitzki D

Aims

Transfusion after primary total hip arthroplasty (THA) has become rare, and identification of causative factors allows preventive measures. The aim of this study was to determine patient-specific factors that increase the risk of needing a blood transfusion.

Methods

All patients who underwent elective THA were analyzed retrospectively in this single-centre study from 2020 to 2021. A total of 2,892 patients were included. Transfusion-related parameters were evaluated. A multiple logistic regression was performed to determine whether age, BMI, American Society of Anesthesiologists (ASA) grade, sex, or preoperative haemoglobin (Hb) could predict the need for transfusion within the examined patient population.


Bone & Joint Open
Vol. 4, Issue 5 | Pages 299 - 305
2 May 2023
Shevenell BE Mackenzie J Fisher L McGrory B Babikian G Rana AJ

Aims

Obesity is associated with an increased risk of hip osteoarthritis, resulting in an increased number of total hip arthroplasties (THAs) performed annually. This study examines the peri- and postoperative outcomes of morbidly obese (MO) patients (BMI ≥ 40 kg/m2) compared to healthy weight (HW) patients (BMI 18.5 to < 25 kg/m2) who underwent a THA using the anterior-based muscle-sparing (ABMS) approach.

Methods

This retrospective cohort study observes peri- and postoperative outcomes of MO and HW patients who underwent a primary, unilateral THA with the ABMS approach. Data from surgeries performed by three surgeons at a single institution was collected from January 2013 to August 2020 and analyzed using Microsoft Excel and Stata 17.0.


Aims

For rare cases when a tumour infiltrates into the hip joint, extra-articular resection is required to obtain a safe margin. Endoprosthetic reconstruction following tumour resection can effectively ensure local control and improve postoperative function. However, maximizing bone preservation without compromising surgical margin remains a challenge for surgeons due to the complexity of the procedure. The purpose of the current study was to report clinical outcomes of patients who underwent extra-articular resection of the hip joint using a custom-made osteotomy guide and 3D-printed endoprosthesis.

Methods

We reviewed 15 patients over a five-year period (January 2017 to December 2022) who had undergone extra-articular resection of the hip joint due to malignant tumour using a custom-made osteotomy guide and 3D-printed endoprosthesis. Each of the 15 patients had a single lesion, with six originating from the acetabulum side and nine from the proximal femur. All patients had their posterior column preserved according to the surgical plan.


Bone & Joint Open
Vol. 5, Issue 6 | Pages 514 - 523
24 Jun 2024
Fishley W Nandra R Carluke I Partington PF Reed MR Kramer DJ Wilson MJ Hubble MJW Howell JR Whitehouse SL Petheram TG Kassam AM

Aims

In metal-on-metal (MoM) hip arthroplasties and resurfacings, mechanically induced corrosion can lead to elevated serum metal ions, a local inflammatory response, and formation of pseudotumours, ultimately requiring revision. The size and diametral clearance of anatomical (ADM) and modular (MDM) dual-mobility polyethylene bearings match those of Birmingham hip MoM components. If the acetabular component is satisfactorily positioned, well integrated into the bone, and has no surface damage, this presents the opportunity for revision with exchange of the metal head for ADM/MDM polyethylene bearings without removal of the acetabular component.

Methods

Between 2012 and 2020, across two centres, 94 patients underwent revision of Birmingham MoM hip arthroplasties or resurfacings. Mean age was 65.5 years (33 to 87). In 53 patients (56.4%), the acetabular component was retained and dual-mobility bearings were used (DM); in 41 (43.6%) the acetabulum was revised (AR). Patients underwent follow-up of minimum two-years (mean 4.6 (2.1 to 8.5) years).


Bone & Joint Open
Vol. 4, Issue 6 | Pages 424 - 431
5 Jun 2023
Christ AB Piple AS Gettleman BS Duong A Chen M Wang JC Heckmann ND Menendez L

Aims

The modern prevalence of primary tumours causing metastatic bone disease is ill-defined in the oncological literature. Therefore, the purpose of this study is to identify the prevalence of primary tumours in the setting of metastatic bone disease, as well as reported rates of pathological fracture, postoperative complications, 90-day mortality, and 360-day mortality for each primary tumour subtype.

Methods

The Premier Healthcare Database was queried to identify all patients who were diagnosed with metastatic bone disease from January 2015 to December 2020. The prevalence of all primary tumour subtypes was tabulated. Rates of long bone pathological fracture, 90-day mortality, and 360-day mortality following surgical treatment of pathological fracture were assessed for each primary tumour subtype. Patient characteristics and postoperative outcomes were analyzed based upon whether patients had impending fractures treated prophylactically versus treated completed fractures.


Bone & Joint Open
Vol. 5, Issue 9 | Pages 809 - 817
27 Sep 2024
Altorfer FCS Kelly MJ Avrumova F Burkhard MD Sneag DB Chazen JL Tan ET Lebl DR

Aims

To report the development of the technique for minimally invasive lumbar decompression using robotic-assisted navigation.

Methods

Robotic planning software was used to map out bone removal for a laminar decompression after registration of CT scan images of one cadaveric specimen. A specialized acorn-shaped bone removal robotic drill was used to complete a robotic lumbar laminectomy. Post-procedure advanced imaging was obtained to compare actual bony decompression to the surgical plan. After confirming accuracy of the technique, a minimally invasive robotic-assisted laminectomy was performed on one 72-year-old female patient with lumbar spinal stenosis. Postoperative advanced imaging was obtained to confirm the decompression.


Bone & Joint Open
Vol. 4, Issue 8 | Pages 551 - 558
1 Aug 2023
Thomas J Shichman I Ohanisian L Stoops TK Lawrence KW Ashkenazi I Watson DT Schwarzkopf R

Aims

United Classification System (UCS) B2 and B3 periprosthetic fractures in total hip arthroplasties (THAs) have been commonly managed with modular tapered stems. No study has evaluated the use of monoblock fluted tapered titanium stems for this indication. This study aimed to evaluate the effects of a monoblock stems on implant survivorship, postoperative outcomes, radiological outcomes, and osseointegration following treatment of THA UCS B2 and B3 periprosthetic fractures.

Methods

A retrospective review was conducted of all patients who underwent revision THA (rTHA) for periprosthetic UCS B2 and B3 periprosthetic fracture who received a single design monoblock fluted tapered titanium stem at two large, tertiary care, academic hospitals. A total of 72 patients met inclusion and exclusion criteria (68 UCS B2, and four UCS B3 fractures). Primary outcomes of interest were radiological stem subsidence (> 5 mm), radiological osseointegration, and fracture union. Sub-analysis was also done for 46 patients with minimum one-year follow-up.


Bone & Joint Open
Vol. 4, Issue 5 | Pages 357 - 362
17 May 2023
Naathan H Ilo K Berber R Matar HE Bloch B

Aims

It is common practice for patients to have postoperative blood tests after total joint replacement (TJR). However, there have been significant improvements in perioperative care with arthroplasty surgery, and a drive to reduce the length of stay (LOS) and move towards day-case TJR. We should reconsider whether this intervention is necessary for all patients.

Methods

This retrospective study included all patients who underwent a primary unilateral TJR at a single tertiary arthroplasty centre during a one-year period. Electronic medical records of 1,402 patients were reviewed for patient demographics, LOS, and American Society of Anesthesiologists (ASA) grade. Blood tests were examined to investigate the incidence of postoperative anaemia, electrolyte abnormalities, and incidence of acute kidney injury (AKI).


Bone & Joint Open
Vol. 5, Issue 7 | Pages 601 - 611
18 Jul 2024
Azarboo A Ghaseminejad-Raeini A Teymoori-Masuleh M Mousavi SM Jamalikhah-Gaskarei N Hoveidaei AH Citak M Luo TD

Aims

The aim of this meta-analysis was to determine the pooled incidence of postoperative urinary retention (POUR) following total hip and knee arthroplasty (total joint replacement (TJR)) and to evaluate the risk factors and complications associated with POUR.

Methods

Two authors conducted searches in PubMed, Embase, Web of Science, and Scopus on TJR and urinary retention. Eligible studies that reported the rate of POUR and associated risk factors for patients undergoing TJR were included in the analysis. Patient demographic details, medical comorbidities, and postoperative outcomes and complications were separately analyzed. The effect estimates for continuous and categorical data were reported as standardized mean differences (SMDs) and odds ratios (ORs) with 95% CIs, respectively.