Aims. Achieving accurate implant positioning and restoring native hip biomechanics are key surgeon-controlled technical objectives in
Total knee arthroplasty (TKA) and total hip arthroplasty
(THA) are recognised and proven interventions for patients with
advanced arthritis. Studies to date have demonstrated a steady increase
in the requirement for primary and revision procedures. Projected
estimates made for the United States show that by 2030 the demand
for primary TKA will grow by 673% and for revision TKA by 601% from
the level in 2005. For THA the projected estimates are 174% and
137% for primary and revision surgery, respectively. The purpose
of this study was to see if those predictions were similar for England
and Wales using data from the National Joint Registry and the Office
of National Statistics. Analysis of data for England and Wales suggest that by 2030,
the volume of primary and revision TKAs will have increased by 117%
and 332%, respectively between 2012 and 2030. The data for the United
States translates to a 306% cumulative rate of increase between
2012 and 2030 for revision surgery, which is similar to our predictions
for England and Wales. The predictions from the United States for primary TKA were similar
to our upper limit projections. For THA, we predicted an increase
of 134% and 31% for primary and revision hip surgery, respectively. Our model has limitations, however, it highlights the economic
burden of arthroplasty in the future in England and Wales as a real
and unaddressed problem. This will have significant implications
for the provision of health care and the management of orthopaedic
services in the future. Cite this article:
The aim of this study was to assess the effect
of frictional torque and bending moment on fretting corrosion at
the taper interface of a modular femoral component and to investigate
whether different combinations of material also had an effect. The
combinations we examined were 1) cobalt–chromium (CoCr) heads on
CoCr stems 2) CoCr heads on titanium alloy (Ti) stems and 3) ceramic
heads on CoCr stems. In test 1 increasing torque was imposed by offsetting the stem
in the anteroposterior plane in increments of 0 mm, 4 mm, 6 mm and
8 mm when the torque generated was equivalent to 0 Nm, 9 Nm, 14
Nm and 18 Nm. In test 2 we investigated the effect of increasing the bending
moment by offsetting the application of axial load from the midline
in the mediolateral plane. Increments of offset equivalent to head
+ 0 mm, head + 7 mm and head + 14 mm were used. Significantly higher currents and amplitudes were seen with increasing
torque for all combinations of material. However, Ti stems showed
the highest corrosion currents. Increased bending moments associated
with using larger offset heads produced more corrosion: Ti stems
generally performed worse than CoCr stems. Using ceramic heads did
not prevent corrosion, but reduced it significantly in all loading
configurations. Cite this article:
The aim of this study was to determine if a change
in antibiotic prophylaxis for routine hip and knee replacement was
associated with an increased risk of acute renal impairment. We identified 238 patients (128 knees and 110 hips) who had received
a single prophylactic dose of 1.5 g cefuroxime before joint replacement.
We compared them with prospectively collected data from 254 patients
(117 knees and 137 hips) who received a single prophylactic dose
of 2 g flucloxacillin and a height- and gender-determined dose of
gentamicin. The primary outcome measure was any new renal impairment
as graded by clinically validated criteria. We identified four patients (1.69%) in the cefuroxime group who
developed renal impairment. All four had mild impairment and all
renal function was normal by the third post-operative day. The incidence
of new-onset renal impairment was significantly higher in the flucloxacillin-and-gentamicin
group at 9.45% (24 patients) (p <
0.001). Three of these patients
remained with acute renal impairment after a week, although the
serum creatinine levels in all subsequently returned to normal. Cite this article:
In this systematic review, our aim was to explore
whether or not patients are able to return to athletic activity
following lower limb joint replacement. We also investigated any evidence
as to whether participation in athletic activity post-joint replacement
increases complications and reduces implant survival. A PubMed, Embase and Sports Discus search was performed using
the MeSH terms ‘Sport’, ‘Athletic’, ‘Athlete’, ‘Physical’, ‘Activity’,
‘Arthroplasty’, ‘Total Hip Replacement’, ‘Hip Resurfacing’, ‘Total
Knee Replacement’, ‘Unicompartmental Knee Replacement’ and ‘Unicondylar
Knee Replacement’. From this search, duplications were excluded,
the remaining abstracts were reviewed and any unrelated to the search
terms were excluded. The remaining abstracts had their full papers
reviewed. Following joint replacement, participation in sporting activity
is common principally determined by pre-operative patient activity
levels, BMI and patient age. The type of joint replaced is of less
significance. Total time spent performing activity does not change
but tends to be at a lower intensity. There is little evidence in
the literature of an association between high activity levels and
early implant failure. Cite this article:
Aims. The primary objective of this study was to develop a validated classification system for assessing iatrogenic bone trauma and soft-tissue injury during
Aims. Conventional patient-reported surveys, used for patients undergoing
Aims. This study aimed to describe practice variation in the use of
Aims. The aim of this study was to evaluate the survival of a collarless, straight, hydroxyapatite-coated femoral stem in
Aims. A significant reduction in wear at five and ten years was previously reported when comparing Durasul highly cross-linked polyethylene with nitrogen-sterilized Sulene polyethylene in
Aims. Femoral component anteversion is an important factor in the success of
Aims. Professional dancers represent a unique patient population in the setting of hip arthroplasty, given the high degree of hip strength and mobility required by their profession. We sought to determine the clinical outcomes and ability to return to professional dance after
Aims. The aims of this systematic review were to assess the learning curve of semi-active robotic arm-assisted
Aims. Postoperative length of stay (LOS) and discharge dispositions following arthroplasty can be used as surrogate measurements for improvements in patients’ pathways and costs. With the increasing use of robotic technology in arthroplasty, it is important to assess its impact on LOS. The aim of this study was to identify factors associated with decreased LOS following robotic arm-assisted
Aims. The aim of this study was to evaluate the reliability and validity of a patient-specific algorithm which we developed for predicting changes in sagittal pelvic tilt after
Aims. The aim of this study was to compare the early postoperative mortality and morbidity in older patients with a fracture of the femoral neck, between those who underwent
Aims. For displaced femoral neck fractures (FNFs) in geriatric patients, there remains uncertainty regarding the effect of
Aims. The prevalence of obesity is increasing substantially around the world. Elevated BMI increases the risk of complications following
Aims. Excessive posterior pelvic tilt (PT) may increase the risk of anterior instability after
Aims. Mechanical impingement of the iliopsoas (IP) tendon accounts for 2% to 6% of persistent postoperative pain after