Advertisement for orthosearch.org.uk
Results 1 - 5 of 5
Results per page:
The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 407 - 410
1 Mar 2013
Legg AJ Hamer AJ

We have recently shown that waste heat from forced-air warming blankets can increase the temperature and concentration of airborne particles over the surgical site. The mechanism for the increased concentration of particles and their site of origin remained unclear. We therefore attempted to visualise the airflow in theatre over a simulated total knee replacement using neutral-buoyancy helium bubbles. Particles were created using a Rocket PS23 smoke machine positioned below the operating table, a potential area of contamination. The same theatre set-up, warming devices and controls were used as in our previous study. This demonstrated that waste heat from the poorly insulated forced-air warming blanket increased the air temperature on the surgical side of the drape by > 5°C. This created convection currents that rose against the downward unidirectional airflow, causing turbulence over the patient. The convection currents increased the particle concentration 1000-fold (2 174 000 particles/m3 for forced-air warming vs 1000 particles/m3 for radiant warming and 2000 particles/m3 for the control) by drawing potentially contaminated particles from below the operating table into the surgical site.

Cite this article: Bone Joint J 2013;95-B:407–10.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 254 - 256
1 Feb 2012
Legg AJ Cannon T Hamer AJ

Patient warming significantly decreases the risk of surgical site infection. Recently there have been concerns that forced air warming may interfere with unidirectional airflow, potentially posing an increased risk of infection. Our null hypothesis was that forced air and radiant warming devices do not increase the temperature and the number of particles over the surgical site when compared with no warming device. A forced air warming device was compared with a radiant warming device and no warming device as a control. The temperature and number of particles were measured over the surgical site. The theatre was prepared as for a routine lower-limb arthroplasty operation, and the same volunteer was used throughout the study. Forced air warming resulted in a significant mean increase in the temperature (1.1°C vs 0.4°C, p < 0.0001) and number of particles (1038.2 vs 274.8, p = 0.0087) over the surgical site when compared with radiant warming, which raises concern as bacteria are known to require particles for transport


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 11 | Pages 1537 - 1544
1 Nov 2011
McGovern PD Albrecht M G. Belani K Nachtsheim C Partington PF Carluke I Reed MR

We investigated the capacity of patient warming devices to disrupt the ultra-clean airflow system. We compared the effects of two patient warming technologies, forced-air and conductive fabric, on operating theatre ventilation during simulated hip replacement and lumbar spinal procedures using a mannequin as a patient. Infection data were reviewed to determine whether joint infection rates were associated with the type of patient warming device that was used. Neutral-buoyancy detergent bubbles were released adjacent to the mannequin’s head and at floor level to assess the movement of non-sterile air into the clean airflow over the surgical site. During simulated hip replacement, bubble counts over the surgical site were greater for forced-air than for conductive fabric warming when the anaesthesia/surgery drape was laid down (p = 0.010) and at half-height (p < 0.001). For lumbar surgery, forced-air warming generated convection currents that mobilised floor air into the surgical site area. Conductive fabric warming had no such effect. A significant increase in deep joint infection, as demonstrated by an elevated infection odds ratio (3.8, p = 0.024), was identified during a period when forced-air warming was used compared to a period when conductive fabric warming was used. Air-free warming is, therefore, recommended over forced-air warming for orthopaedic procedures


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 4 | Pages 486 - 488
1 May 2002
Sharp RJ Chesworth T Fern ED

Patient warming systems are used routinely to prevent hypothermia under anaesthesia. Airflow from warming blankets may potentially influence bacterial counts either by pumping ‘dirty air’ from floor level to the operating area or by blowing the patients’ skin cells into the operating field from airflow under the blanket. Using slit-air sampling we analysed the air quality within a laminar-flow theatre at a simulated operating site. We assessed the effect of ‘high shedding of skin’ under the blanket using volunteer patients with psoriasis. We also simulated general theatre activity outside the laminar-flow area in order to determine whether the bacterial counts in the operating field were affected. No colonies were grown in any of the groups tested and our results suggest that the patient warming system does not influence bacterial counts at the operating site in an ultraclean air-ventilated theatre, even with patients who have high shedding of skin cells


The Bone & Joint Journal
Vol. 98-B, Issue 12 | Pages 1635 - 1641
1 Dec 2016
Arverud ED Anundsson P Hardell E Barreng G Edman G Latifi A Labruto F Ackermann PW

Aims

Patients with an acute Achilles tendon rupture (ATR) take a long time to heal, have a high incidence of deep vein thrombosis (DVT) and widely variable functional outcomes. This variation in outcome may be explained by a lack of knowledge of adverse factors, and a subsequent shortage of appropriate interventions.

Patients and Methods

A total of 111 patients (95 men, 16 women; mean age 40.3, standard deviation 8.4) with an acute total ATR were prospectively assessed. At one year post-operatively a uniform outcome score, Achilles Combined Outcome Score (ACOS), was obtained by combining three validated, independent, outcome measures: Achilles tendon Total Rupture Score, heel-rise height test, and limb symmetry heel-rise height. Predictors of ACOS included treatment; gender; age; smoking; body mass index; time to surgery; physical activity level pre- and post-injury; symptoms; quality of life and incidence of DVT.