Validation of central peak height method for final adult height predictions on long leg radiographs



Download PDF

Abstract

Aims

Accurate skeletal age and final adult height prediction methods in paediatric orthopaedics are crucial for determining optimal timing of growth-guiding interventions and minimizing complications in treatments of various conditions. This study aimed to evaluate the accuracy of final adult height predictions using the central peak height (CPH) method with long leg X-rays and four different multiplier tables.

Methods

This study included 31 patients who underwent temporary hemiepiphysiodesis for varus or valgus deformity of the leg between 2014 and 2020. The skeletal age at surgical intervention was evaluated using the CPH method with long leg radiographs. The true final adult height (FHTRUE) was determined when the growth plates were closed. The final height prediction accuracy of four different multiplier tables (1. Bayley and Pinneau; 2. Paley et al; 3. Sanders – Greulich and Pyle (SGP); and 4. Sanders – peak height velocity (PHV)) was then compared using either skeletal age or chronological age.

Results

All final adult height predictions overestimated the FHTRUE, with the SGP multiplier table having the lowest overestimation and lowest absolute deviation when using both chronological age and skeletal age. There were no significant differences in final height prediction accuracy between using skeletal age and chronological age with PHV (p = 0.652) or SGP multiplier tables (p = 0.969). Adult height predictions with chronological age and SGP (r = 0.769; p ≤ 0.001), as well as chronological age and PHV (r = 0.822; p ≤ 0.001), showed higher correlations with FHTRUE than predictions with skeletal age and SGP (r = 0.657; p ≤ 0.001) or skeletal age and PHV (r = 0.707; p ≤ 0.001).

Conclusion

There was no significant improvement in adult height prediction accuracy when using the CPH method compared to chronological age alone. The study concludes that there is no advantage in routinely using the CPH method for skeletal age determination over the simple use of chronological age. The findings highlight the need for more accurate methods to predict final adult height in contemporary patient populations.

Cite this article: Bone Jt Open 2023;4(10):750–757.

Take home message

The study concludes that there is no advantage in routinely using the central peak height (CPH) method for skeletal age determination over the simple use of chronological age.

The findings highlight the need for more accurate methods to predict final adult height in contemporary patient populations.

Introduction

Accurate estimation of skeletal maturity is important for the treatment of various paediatric endocrinological and orthopaedic conditions, such as leg length discrepancies or malalignment of the lower limbs in the frontal plane. In this context, precise prediction of residual growth is essential to determine the optimal timing for growth-guiding interventions, and to reduce the rate of over-correction, under-correction, and the development of rebounds.1-3 Various approaches exist for determining remaining growth potential and the optimal timing for epiphysiodesis procedures. These methods can be categorized into two primary groups: those that rely on chronological age and those that use skeletal age for their calculations. Studies comparing these methods have yielded mixed findings about whether skeletal age- or chronological age-based techniques have superior accuracy in final body height predictions. While studies by Little et al4 and Aguilar et al5 found no significant difference between methods using skeletal age or chronological age, more recent research has demonstrated greater accuracy when using skeletal age-based methods. In a 2011 study by Sanders et al,6 the authors compared the effectiveness of chronological age and skeletal maturity for predicting mature limb length in children. Their findings suggested that chronological age-based predictions were more accurate for younger children, while skeletal age-based predictions provided better estimates during adolescence.

The most commonly used methods to determine skeletal age are the Greulich and Pyle (GP) bone age atlas,7 the Sauvegrain method,8 and the Tanner-Whitehouse classification.9 These assessments are limited by the subjective nature of interpretation and the need to obtain additional radiographs, e.g. of the hand or elbow.10 The additional radiation exposure must be considered, especially in young patients, because the likelihood of radiation-induced malignancy is a function of the patients’ age.11 In order to prevent unnecessary radiation exposure, Knapik et al12 published the first purely numerical method for determining skeletal age on anteroposterior (AP) knee radiographs (central peak height (CPH) method). This method was validated by using a historical dataset from the Bolton-Brush study collection, which was also used to develop the GP bone age atlas.12

To calculate the final adult height, additional calculations based on the determined skeletal age or chronological age are required, for example by using multiplier tables.13 The best known multiplier tables were published by Bayley and Pinneau,14 Paley et al,13 and Sanders.15,16 Multiplier tables have been commonly used in paediatric orthopaedics to estimate final adult height using either skeletal age or chronological age. While the use of multiplier tables can provide a quick and easy way to estimate final adult height, their accuracy has been called into question in recent years and no multiplier could clearly emerge as the most accurate.6 Furthermore, the multiplier tables by Bayley and Pinneau as well as by Sanders were developed using historical data from the Brush Foundation Study of Child Growth and Development and Berkeley Guidance Studies of the Institute of Human Development, which mainly enrolled Caucasian, affluent, and healthy children.14,15,17,18 Thus, their applicability on a current, diverse patient clientele with an axial deviation in the frontal plane may be limited.

The goal of the present study was to evaluate the accuracy of final adult height predictions using the CPH method with long leg radiographs and four different multiplier tables. We asked the following research questions: is the CPH method in combination with multiplier tables an accurate method to determine skeletal age and the final adult height on AP long leg radiographs? Is the accuracy of this method superior to the simple use of chronological age for final adult height predictions? Which combination of chronological age or skeletal age (calculated by CPH method) and multiplier table correlates best with final adult height?

Methods

Patients

This single-centre, retrospective study was approved by the review board of the Goethe University in Frankfurt. All investigations were performed in accordance with relevant guidelines and regulations. Using our prospectively maintained institutional database, we identified 52 patients who were treated for idiopathic varus or valgus deformity of the leg and underwent temporary hemiepiphysiodesis between October 2014 and September 2020. All patients had – as standard of care – a preoperative long leg radiograph in an AP orientation. Criteria for a valid full leg length AP radiological image were: patient standing in a weightbearing and upright position; both legs parallel to each other; fully extended knees; and patella centred over the femoral condyles pointing straight forward in order to avoid rotational errors.

The indication for implant-mediated growth guidance with hemiepiphysiodesis plating (Eight-Plates (Orthofix, USA) or Pedi-Plates (OrthoPediatrics, USA)) was set for skeletally immature patients with a pathological idiopathic valgus or varus alignment deformity of both lower limbs.19,20 Patients were followed frequently in three- to six-month intervals until reaching adult stature (at least until 1.5 years after implant removal (mean age 15.80 years (standard deviation (SD) 1.22)). The true final adult height (FHTRUE) was set as the primary endpoint. FHTRUE was determined when growth plates of the knee joint were closed and when there was no further increase in body height within 12 months. Patients’ heights were measured in a standardized manner using the same calibrated measuring device.

Patients were excluded if FHTRUE could not be determined (n = 19) or if the imaging was not suitable for evaluation (n = 2) due to incomplete or rotated visualization of the area of interest. Further exclusion criteria were: neuromuscular disorders, rheumatoid arthritis, achondroplasia or hypochondroplasia, knee surgery within 12 months before enrolment in this study, sagittal plane deformities (genu pro- and recurvatum), flexion contractures in the hip or knee joint, leg length discrepancy of > 10 mm, avascular necrosis of the femoral head or knee condyles, or history of severe trauma or sport injury to the lower limbs. Ultimately, 31 patients (62 knees) with a mean age of 13.15 years (SD 1.09) at the time of implantation of the plates were included in the study.

Central peak height method

Skeletal age at the time of surgical intervention (SASI) was determined using the CPH method.12 First, a scalable, standardized, digital long leg radiograph was taken in an AP orientation no more than one month before surgery and used to evaluate the central peak value (CPV). The individual magnification factor was determined by a 25.4 mm-diameter metal ball, which was placed between the legs at the level of the knee joint line. The CPV was calculated by dividing the distance between the central peak of the distal femoral physis and a line between the medial and lateral ends of the distal femoral physis by the width of the distal femoral physis (Figure 1). According to Knapik et al,12 patients’ chronological age at 90% of final height (CA90%FH) was calculated using chronological age at the time of surgical intervention (CASI) using the following equation:

(1) C A 90 % F H = 3.495 + ( 15.409 × C P V ) + ( 0.658 × C A S I ) + ( 0.661 × s e x [ f e m a l e = 0 ; m a l e = 1 ] )

Fig. 1 
            Determination of skeletal age using the central peak height method on a long leg radiograph (age 11 years 9 months, female). First, a scalable, standardized, digital long leg radiograph was taken in an anteroposterior orientation no more than one month before surgery and used to evaluate the central peak value (CPV). The CPV was calculated by dividing the distance between the central peak of the distal femoral physis and a line between the medial and lateral ends of the distal femoral physis (7 mm) by the width of the distal femoral physis (73 mm). The CPV value was then used to determine skeletal age.

Fig. 1

Determination of skeletal age using the central peak height method on a long leg radiograph (age 11 years 9 months, female). First, a scalable, standardized, digital long leg radiograph was taken in an anteroposterior orientation no more than one month before surgery and used to evaluate the central peak value (CPV). The CPV was calculated by dividing the distance between the central peak of the distal femoral physis and a line between the medial and lateral ends of the distal femoral physis (7 mm) by the width of the distal femoral physis (73 mm). The CPV value was then used to determine skeletal age.

In previously studied populations, females reached 90% of final height at age 11 years 4 months and males at age 13 years 2 months.21 Under this assumption, skeletal age at the time of surgical intervention (SASI_CPH) was calculated by the following equations:

(2) F e m a l e s :   S A S I _ C P H   =   C A S I     ( 11.4     C A 90 %   F H )

(3) M a l e s :   S A S I _ C P H   =   C A S I     ( 13.2     C A 90 %   F H )

Since all patients received surgery on both legs, the mean of the right and left CPV was calculated and used for further analysis.

Multiplier tables

Next, four different multiplier tables were used to predict the final adult height of the patients (FHPRE) based on either CASI and/or SASI_CPH:

A) Multiplier according to Bayley and Pinneau:14 Bayley and Pinneau (BP) differentiated between delayed (SASI - CASI < -1), average (SASI - CASI = ± 1), and accelerated (SASI - CASI > 1) skeletal maturity. They published three different multiplier tables for the respective groups. After the type of skeletal maturity was determined, the final adult height of the patients (FHPRE_BP) was calculated using the following equation:

(4) F H P R E _ B P   =   H e i g h t S I     ( 100   /   B P   m u l t i p l i e r   v a l u e )

Since the CPH method also determines skeletal ages that lie between the intervals of three months, a linear relationship between two neighbouring multiplier values was assumed and thus the missing percentages were added (Supplementary Table i).

B) Multiplier according to Paley et al:13 Paley et al (P) used data from the Centers for Disease Control and Prevention to create multiplier tables. The tables were developed considering CASI (and sex) to determine the respective multiplier value. The final adult height of the patients (FHPRE_P) was then calculated using the following equation:

(5) F H P R E _ P   =   H e i g h t S I     P   m u l t i p l i e r   v a l u e

C) Multiplier according to Sanders – Greulich and Pyle:15 Sanders et al (SGP) used data from the Bolton-Brush Study Foundation to predict SASI and FHpre by using the GP atlas. Again, a linear relationship between two neighbouring multiplier values was assumed and thus the missing percentages were added (Supplementary Table ii). The final adult height of the patients (FHPRE_SGP) was calculated using the following equation:

(6) F H P R E _ S G P   =   H e i g h t S I     S G P   m u l t i p l i e r   v a l u e

D) Multiplier according to Sanders – peak height velocity (PHV) (2021):16 Sanders et al developed multiplier tables based on 90% final adult height. To use these multipliers for final adult height predictions, the distance between the mean age at 90% final adult height of the reference population (male: 11 years 4 months; female: 13 years 2 months) and the skeletal age or chronological age was calculated and used to create the adapted multiplier tables (Supplementary Table iii). The final adult height of the patients (FHPRE_PHV) was calculated using the following equation:

(7) F H P R E _ P H V   =   H e i g h t S I     P H V   m u l t i p l i e r   v a l u e

CASI as well as SASI_CPH were used to evaluate the respective multiplier value. The use of CASI or SASI_CPH in combination with four different multiplier tables (A to D) resulted in a total of eight predictions of FHPRE.

Statistical analysis

Statistical analysis was performed using SPSS version 29 (IBM, USA). The accuracy of adult height prediction was determined by comparing the mean differences (δ = FHPRE - FHTRUE) and the mean absolute differences (δ Absolut = │FHPRE - FHTRUE│) between the respective FHPRE and FHTRUE. The Shapiro-Wilk test was used to test normal distribution of the analyzed parameters. Continuous and normally distributed variables were presented as the mean (SD). Non-parametric variables were presented as the median and interquartile range (IQR), and were compared between two groups using the Wilcoxon signed-rank test. Multiple paired groups were compared with the Friedman test. If the significance level for the Friedman test was less than 0.05, multiple comparisons were performed using the Dunn-Bonferroni post-hoc test. The calculated and normally distributed FHPRE values were correlated to FHTRUE using the Pearson correlation coefficient (r). The significance level was set at p ≤ 0.05.

Results

All FHPRE overestimated FHTrue

The mean FHTrue was 178.6 cm (156.8 to 193.2). Comparing the means of all adult body height predictions, all of these predictions overestimated the FHTrue (Figure 2). When simply using CASI for adult height predictions, the SGP multiplier table showed the lowest overestimation (mean 3.51 cm (-10.8 to 15.1)), followed by the Sanders PHV multiplier table (mean 4.19 cm (-8.6 to 14.2)). In addition, the SGP multiplier table showed the lowest overestimation (mean 1.38 cm (-12.0 to 17.8)) when using SASI_CPH (Table I).

Fig. 2 
            Overview of the calculated final adult height predictions compared to the true adult height (FHTrue). First, the chronological age at the time of surgery was used to predict the final size (FHPRECA) using the four different multiplier tables (Bayley and Pinneau (BP); Paley et al (P); Sanders – Greulich and Pyle (SGP); Sanders – peak height velocity (PHV)). Second, skeletal age was determined using the central peak height method. SA at the time of surgery was used to predict the final size (FHPRESA) using the four different multiplier tables. The red line shows the mean true adult height. Data represent medians with interquartile ranges. Whiskers represent minimum and maximum values.

Fig. 2

Overview of the calculated final adult height predictions compared to the true adult height (FHTrue). First, the chronological age at the time of surgery was used to predict the final size (FHPRECA) using the four different multiplier tables (Bayley and Pinneau (BP); Paley et al (P); Sanders – Greulich and Pyle (SGP); Sanders – peak height velocity (PHV)). Second, skeletal age was determined using the central peak height method. SA at the time of surgery was used to predict the final size (FHPRESA) using the four different multiplier tables. The red line shows the mean true adult height. Data represent medians with interquartile ranges. Whiskers represent minimum and maximum values.

Table I.

Final adult height predictions.

Body height specifications Mean, cm SD, cm Range, cm Mean delta (FHPRE - FHTRUE), cm SD, cm Range, cm Median delta absolut (FHPRE - FHTRUE), cm IQR, cm
Body heightSI 169.74 8.21 152.50 to 183.00
FHTRUE 178.55 9.03 156.80 to 193.20
Chronological age
FHPRE_CA_BP 184.55 8.75 166.12 to 204.59 6.01 4.96 -5.91 to 15.99 7.31 3.30 to 10.00
FHPRE_CA_P 184.99 8.35 166.99 to 204.12 6.45 4.99 -5.48 to 15.52 7.40 3.48 to 10.03
FHPRE_CA_SGP 182.05 6.07 168.36 to 198.26 3.51 5.84 -10.76 to 15.14 4.71 1.44 to 9.66
FHPRE_CA_PHV 182.73 7.58 165.92 to 201.37 4.19 5.14 -8.55 to 14.19 4.80 2.36 to 7.75
CPH
FHPRE_SA_BP 182.14 7.92 166.33 to 200.99 3.59 5.98 -8.30 to 13.62 4.82 2.83 to 9.09
FHPRE_SA_P 182.45 7.75 165.83 to 200.82 3.90 6.41 -8.04 to 18.54 4.69 2.81 to 8.13
FHPRE_SA_SGP 179.92 6.00 167.46 to 194.79 1.38 6.80 -11.95 to 17.83 3.86 2.23 to 7.30
FHPRE_SA_PHV 180.61 7.12 164.74 to 197.71 2.06 6.43 -10.42 to 17.83 3.98 2.27 to 7.02
  1. Bold font highlights lowest mean delta value and lowest median delta absolute value of both adult height prediction methods.

  1. BP, Bayley and Pinneau; CA, chronological age; CPH, central peak height; FHPRE, predicted final adult height; FHTRUE, true final adult height; Max, maximum; Min, minimum; P, Paley et al; PHV, peak height velocity; SA, skeletal age; SD, standard deviation; SGP, Sanders – Greulich and Pyle.

The SGP multiplier table had the lowest absolute deviation between FHPRE and FHTrue

When comparing the absolute deviation between FHPRE and FHTrue (δ Absolut =│FHPRE-FHTRUE│), SASI_CPH in combination with the SGP multiplier table showed the lowest median value (3.86 cm (IQR 2.2 to 7.3)) (Figure 3). In addition, the SGP multiplier table showed the lowest median absolute deviation (4.71 cm (IQR 1.4 to 9.7)) when using CASI (Table I).

Fig. 3 
            Final adult height prediction accuracy. The accuracy of adult height prediction was determined by comparing the mean absolute differences between the respective predicted final adult height (FHPRE) using the four different multiplier tables (Bayley and Pinneau (BP); Paley et al (P); Sanders – Greulich and Pyle (SGP); Sanders – peak height velocity (PHV)) and the true final adult height (FHTRUE) (δ Absolut = │FHPRE - FHTRUE│). Data represent medians with interquartile ranges. Whiskers represent minimum and maximum values. *p = 0.047, Dunn-Bonferroni post-hoc test.

Fig. 3

Final adult height prediction accuracy. The accuracy of adult height prediction was determined by comparing the mean absolute differences between the respective predicted final adult height (FHPRE) using the four different multiplier tables (Bayley and Pinneau (BP); Paley et al (P); Sanders – Greulich and Pyle (SGP); Sanders – peak height velocity (PHV)) and the true final adult height (FHTRUE) (δ Absolut = │FHPRE - FHTRUE│). Data represent medians with interquartile ranges. Whiskers represent minimum and maximum values. *p = 0.047, Dunn-Bonferroni post-hoc test.

CPH method did not significantly improve adult body height prediction accuracy

When using CASI for adult height predictions, the δ absolute values between the four multiplier tables differed significantly (p = 0.027, Friedman test). There was a significant difference between the δ absolute values calculated by Sanders PHV-multiplier and the δ absolute values calculated by BP-multiplier (p = 0.047, Dunn-Bonferroni post-hoc test). No significant differences between the δ absolute values of the other multiplier tables were detected. When using SASI_CPH for adult height predictions, we found no significant difference between the four multiplier tables (p = 0.838, Friedman test).

No differences in final height prediction accuracy (δ absolute values) between SASI_CPH and CASI were found when using the most accurate PHV multiplier (p = 0.652) or SGP multiplier tables (p = 0.969, both Wilcoxon signed-rank test). Furthermore, adult height predictions with CASI and SGP (r = 0.769; p ≤ 0.001), as well as CASI and PHV (r = 0.822; p ≤ 0.001), showed higher correlations with FHTRUE than adult height predictions with SASI_CPH (r = 0.657; p ≤ 0.001) and SGP, as well as SASI_CPH and PHV (r = 0.707; p ≤ 0.001) (Table II).

Table II.

Correlation analysis between predicted and true final adult height.

FHPRE_CA_BP FHPRE_CA_P FHPRE_CA_SGP FHPRE_CA_PHV FHPRE_SA_BP FHPRE_SA_P FHPRE_SA_SGP FHPRE_SA_PHV
FHTRUE Pearson correlation (r) 0.845 0.838 0.769 0.822 0.759 0.718 0.657 0.707
Sig. (two-sided) ≤ 0.001 ≤ 0.001 ≤ 0.001 ≤ 0.001 ≤ 0.001 ≤ 0.001 ≤ 0.001 ≤ 0.001
  1. BP, Bayley and Pinneau; CA, chronological age; FHPRE, predicted final adult height; FHTRUE, true final adult height; P, Paley et al; PHV, peak height velocity; SGP, Sanders – Greulich and Pyle; Sig., significance.

Discussion

In this study, the accuracy of different methods for predicting final adult height in patients who underwent temporary hemiepiphysiodesis for leg deformities was evaluated. SASI was determined using the CPH method, and four different multiplier tables were used to predict FHPRE. All final adult height predictions overestimated FHTRUE. The SGP-multiplier table showed lowest absolute deltas, and thus the most accurate results, in final adult height predictions using both CASI and SASI_CPH. However, the use of the more complicated and time-consuming CPH method did not increase the final height prediction accuracy.

It remains unclear why even validated multiplier tables, such as the one according to Bayley and Pinneau,22,23 significantly overestimated FHTRUE. Two possible explanations could account for this discrepancy. First, the patients in this study – or patients with varus or valgus malalignment in general – have growth characteristics that are not considered in the multiplier tables or in the CPH method. Most multiplier tables and the CPH method were developed on historical patient cohorts, which might have different skeletal maturity patterns compared to contemporary populations. Paley et al13 showed that height multipliers were consistent across generations. However, as the performance of the Paley multipliers was unsatisfactory in this study, we suggest further inquiries and, if necessary, an updated version that reflects better a current, diverse population with malalignment. It is possible that growth-guiding interventions could result in a lower final height. To test this latter hypothesis, a study design with patients who have undergone hemiepiphysiodesis on only one side could be considered, as growth inhibition caused by the intervention would manifest as a difference in leg length.

We compared four different multiplier tables: Bayley and Pinneau,14 Paley et al,13 SGP,15 and Sanders – PHV.16 We found that using the Paley multiplier table was by far the easiest, as the use of the app ‘Paley Growth’ eliminated the need for multiplication tables and calculators. Our study showed that height predictions using CASI and the Paley multiplier table had a high correlation with actual height (r = 0.838; p < 0.001). However, the table tended to overestimate FHTRUE by a mean delta of 6.45 cm, which was the highest among the four tables compared. We did not find a significant difference between Paley’s multiplier table and the Bayley and Pinneau multiplier table (CASI: p = 1.000 (Dunn-Bonferroni post-hoc test); SASI_CPH: p = 0.838 (Friedman test)), which was expected due to the small differences between the multiplier values as previously stated by Paley et al.13 In 2017, Sanders et al15 published a multiplier table based on the Brush Foundation Study of Child Growth and Development dataset and skeletal ages using the GP atlas.18 It has not yet been further validated for height predictions. The additional multiplier table published by Sanders et al16 in 2021 takes a different approach than any multiplier previously developed. The timepoints with the highest growth rates were identified and used as a baseline to develop the multiplier tables. Sanders et al16 found that their multiplier table – Sanders PHV – provided better results than the Paley multipliers during the ages of pubertal growth spurt. This is confirmed in our study. In addition, a superior accuracy of the SGP multiplier could be shown by our study, as it elucidated less overprediction than the Paley multiplier table when using CASI (mean 3.51 cm (SD 5.84) vs 6.01 cm (SD 4.96)). Future studies should consider using the SGP multiplier for improved accuracy.

The CPH method is the first purely numerical method for skeletal age determination,12 developed with the intention of being user-friendly and to reduce the need for additional imaging and associated radiation exposure. However, the use of the CPH method did not significantly increase the accuracy of final height prediction. This contrasts with the findings of Knapik et al,12 who compared their method with the GP atlas method in combination with sex and chronological age, as well as sex alone. For both combinations, they developed corresponding equations to predict CA90%FH and showed that the CPH method was better at predicting this timepoint than the combination of chronological age and sex, as well as sex alone. To validate their method, Knapik et al12 used data from 81 healthy children who were enrolled in the Bolton-Brush Growth Study between 1929 and 1942, whereas our study included a more diverse patient population with axial deviation in the frontal plane. Furthermore, we found that the practical application of the CPH method is limited by the fact that the acquisition and measurement of radiological images is prone to error. The growth plate is often depicted more than once due to its 3D nature on a 2D (AP) radiograph, and the medial or lateral margins of the epiphysis can be difficult to distinguish. Additionally, even small deviations in the measurement of CPV can result in significant changes in skeletal age estimation. This is reflected in the high standard deviations of the height predictions.

There are limitations of the study. First, no healthy control group was included in the study. Therefore, it cannot be conclusively assessed whether the study is transferable to a healthy patient population or a patient population with a different pathology. Likewise, it cannot be assessed whether an axial deformity in the frontal plane and its correction using tension band plating have an influence on the final body height. However, the inclusion of a healthy control group would not have been justifiable from an ethical point of view due to radiation exposure. It is worth noting that in this study, chronological age and skeletal age were used with each multiplier table, even though the tables of Bayley and Pinneau, SGP, and Sanders – PHV were intended to be used with skeletal age. This decision was made to avoid potential sources of error in determining skeletal age. However, although we used skeletal age as well, we found that it did not improve the accuracy of the multiplier tables intended for use with skeletal age. This suggests that skeletal age only enhances height predictions if it more accurately reflects true biological age compared to current chronological age. Whether this is the case depends on the performance of the skeletal age determining method in use, the quality of the radiograph image, and the examiner’s experience.

In conclusion, the CPH method for determining skeletal age did not improve final adult height predictions. Therefore, the results of this study suggest that routine use of the CPH method for skeletal age determination in patients with idiopathic varus or valgus deformity of the leg offers no advantage over the simple use of chronological age in terms of accuracy of final height prediction. Of all four multiplier methods tested in this study, the most accurate size predictions were obtained using the SGP multiplier table. Overall, this study highlights the importance of considering the accuracy of the methods used to predict final adult height in young patients. It suggests that the currently available methods may not be accurate for modern patient populations and that more accurate methods may need to be developed and validated.


Correspondence should be sent to Marco Brenneis. E-mail:

F. Stief and S. Braun contributed equally to this work.


References

1. Stief F , Holder J , Böhm H , Meurer A . Prevalence and predictors of rebound deformity in the frontal plane: A literature review . Orthopade . 2021 ; 50 ( 7 ): 548 558 . (Article in German) Crossref PubMed Google Scholar

2. De Sanctis V , Di Maio S , Soliman AT , Raiola G , Elalaily R , Millimaggi G . Hand X-ray in pediatric endocrinology: Skeletal age assessment and beyond . Indian J Endocrinol Metab . 2014 ; 18 ( Suppl 1 ): S63 71 . Crossref PubMed Google Scholar

3. Willegger M , Bouchard M , Windhager R , Kolb A , Chiari C . Epiphysiodesis and hemiepiphysiodesis: Physeal arrest and guided growth for the lower extremity . Orthopade . 2022 ; 51 ( 5 ): 415 432 . Crossref PubMed Google Scholar

4. Little DG , Nigo L , Aiona MD . Deficiencies of current methods for the timing of epiphysiodesis . J Pediatr Orthop . 1996 ; 16 ( 2 ): 173 179 . Crossref PubMed Google Scholar

5. Aguilar JA , Paley D , Paley J , et al. Clinical validation of the multiplier method for predicting limb length discrepancy and outcome of epiphysiodesis, part II . J Pediatr Orthop . 2005 ; 25 ( 2 ): 192 196 . Crossref PubMed Google Scholar

6. Sanders JO , Howell J , Qiu X . Comparison of the Paley method using chronological age with use of skeletal maturity for predicting mature limb length in children . J Bone Joint Surg Am . 2011 ; 93-A ( 11 ): 1051 1056 . Crossref PubMed Google Scholar

7. Greulich WW , Pyle SI . Radiographic Atlas of Skeletal Development of the Hand and Wrist . 2nd ed . Redwood City, California : Stanford University Press , 1959 . Crossref Google Scholar

8. Diméglio A , Charles YP , Daures J-P , de Rosa V , Kaboré B . Accuracy of the Sauvegrain method in determining skeletal age during puberty . J Bone Joint Surg Am . 2005 ; 87-A ( 8 ): 1689 1696 . Crossref PubMed Google Scholar

9. Tanner JM , Whitehouse RH , Marshall WA , Carter BS . Prediction of adult height from height, bone age, and occurrence of menarche, at ages 4 to 16 with allowance for midparent height . Arch Dis Child . 1975 ; 50 ( 1 ): 14 26 . Crossref PubMed Google Scholar

10. Breen AB , Steen H , Pripp A , Hvid I , Horn J . Comparison of different bone age methods and chronological age in prediction of remaining growth around the knee . J Pediatr Orthop . 2023 ; 43 ( 6 ): 386 391 . Crossref PubMed Google Scholar

11. Dendy PP , Brugmans MJP . Low dose radiation risks . Br J Radiol . 2003 ; 76 ( 910 ): 674 677 . Crossref PubMed Google Scholar

12. Knapik DM , Sanders JO , Gilmore A , Weber DR , Cooperman DR , Liu RW . A quantitative method for the radiological assessment of skeletal maturity using the distal femur . Bone Joint J . 2018 ; 100-B ( 8 ): 1106 1111 . Crossref PubMed Google Scholar

13. Paley J , Talor J , Levin A , Bhave A , Paley D , Herzenberg JE . The multiplier method for prediction of adult height . J Pediatr Orthop . 2004 ; 24 ( 6 ): 732 737 . Crossref PubMed Google Scholar

14. Bayley N , Pinneau SR . Tables for predicting adult height from skeletal age: revised for use with the Greulich-Pyle hand standards . J Pediatr . 1952 ; 40 ( 4 ): 423 441 . Crossref PubMed Google Scholar

15. Sanders JO , Qiu X , Lu X , et al. The uniform pattern of growth and skeletal maturation during the human adolescent growth spurt . Sci Rep . 2017 ; 7 ( 1 ): 16705 . Crossref PubMed Google Scholar

16. Sanders JO , Karbach LE , Cai X , Gao S , Liu RW , Cooperman DR . Height and extremity-length prediction for healthy children using age-based versus peak height velocity timing-based multipliers . J Bone Joint Surg Am . 2021 ; 103-A ( 4 ): 335 342 . Crossref PubMed Google Scholar

17. Tuddenham RD , Snyder MM . Physical growth of California boys and girls from birth to eighteen years . Publ Child Dev Univ Calif . 1954 ; 1 ( 2 ): 183 364 . PubMed Google Scholar

18. Simmons K , Greulich WW . The Brush Foundation Study of Child Growth and Development: II. Physical Growth and Development . Monographs of the Society for Research in Child Development . 1944 ; 9 ( 1 ). Crossref Google Scholar

19. Ruchholtz S , Wirtz DC . Orthopädie Und Unfallchirurgie essentials . Second ed . Stuttgart : Georg Thieme , 2013 . Google Scholar

20. Vogt B , Schiedel F , Rödl R . Guided growth in children and adolescents. Correction of leg length discrepancies and leg axis deformities . Orthopade . 2014 ; 43 ( 3 ): 267 284 . (Article in German) Crossref PubMed Google Scholar

21. Benedick A , Knapik DM , Duren DL , et al. Systematic Isolation of Key Parameters for Estimating Skeletal Maturity on Knee Radiographs . J Bone Joint Surg Am . 2021 ; 103-A ( 9 ): 795 802 . Crossref PubMed Google Scholar

22. Roemmich JN , Blizzard RM , Peddada SD , et al. Longitudinal assessment of hormonal and physical alterations during normal puberty in boys. IV: Predictions of adult height by the Bayley-Pinneau, Roche-Wainer-Thissen, and Tanner-Whitehouse methods compared . Am J Hum Biol . 1997 ; 9 ( 3 ): 371 380 . Crossref PubMed Google Scholar

23. Zachmann M , Sobradillo B , Frank M , Frisch H , Prader A . Bayley-Pinneau, Roche-Wainer-Thissen, and Tanner height predictions in normal children and in patients with various pathologic conditions . J Pediatr . 1978 ; 93 ( 5 ): 749 755 . Crossref PubMed Google Scholar

Author contributions

M. Brenneis: Conceptualization, Data curation, Investigation, Methodology, Formal analysis, Visualization, Writing – original draft, Writing – review & editing.

N. Thewes: Data curation, Investigation, Visualization, Writing – original draft, Writing – review & editing.

J. Holder: Investigation, Visualization, Writing – original draft, Writing – review & editing.

F. Stief: Conceptualization, Investigation, Visualization, Formal analysis, Supervision, Validation, Methodology, Project administration, Writing – original draft, Writing – review & editing.

S. Braun: Conceptualization, Data curation, Investigation, Methodology, Formal analysis, Visualization, Writing – original draft, Writing – review & editing.

Funding statement

The authors disclose receipt of the following financial or material support for the research, authorship, and/or publication of this article: research reported in this publication was funded by the Deutsche Forschungsgemeinschaft (DFG, German Research Foundation) - Project number: 403837822.

ICMJE COI statement

J. Holder reports travel payments from Gesellschaft für die Analyse Menschlicher Motorik und ihre klinische Anwendung (GAMMA) and Deutsche Gesellschaft für Biomechanik (DGfB), unrelated to this study.

Data sharing

The data that support the findings for this study are available to other researchers from the corresponding author upon reasonable request.

Ethical review statement

This single-centre, retrospective study was approved by the institutional review board of the Goethe University Frankfurt (182/16). The participants and their parents provided written informed consent to participate in this study. All investigations were performed in accordance with relevant guidelines and regulations.

Open access funding

The authors report that they received open access funding from the Open Access Publication Fund of the Frankfurt University Library.

Supplementary material

Respective multiplier tables used in this study.

© 2023 Author(s) et al. This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives (CC BY-NC-ND 4.0) licence, which permits the copying and redistribution of the work only, and provided the original author and source are credited. See https://creativecommons.org/licenses/by-nc-nd/4.0/