Advertisement for orthosearch.org.uk
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

General Orthopaedics

THE USE OF PET-CT REDUCES MORTALITY IN PATIENTS WITH IMPLANT-RELATED INFECTION ASSOCIATED WITH STAPHYLOCCOCUS AUREUSBACTEREMIA

European Bone and Joint Infection Society (EBJIS) meeting, Antwerp, Belgium, September 2019.



Abstract

Aim

Staphylococcus aureus bacteremia (SAB) is associated with significant morbidity and mortality, 20ā€“30 % risk of infection in patient with implant related infection (IRI) .18F-FDG PET/CT is helpful in the management of SAB, leading to detection of more metastatic foci and treatment modification and finally decrease relapses and mortality rate. Our objective was to analyze mortality in high risk SAB patients undergoing 18F-FDG PET/CT and to see whether it's use in patients with IRI reduced their mortality.

Method

We performed a retrospective study at a university hospital in Belgium. All cases of high risk adult SAB between January 2014 and June 2017 were reviewed. We collected the clinical characteristics including presence of metastatic foci on 18F-FDG PET/ CT, mortality at 1 year.

Results

A total of 102 patients were included. Twenty-one patient with IRI were identified (20.6%). In 94.1 % (N=96) SAB were due to methicillin-sensitive staphylococcus aureus (MSSA). 18F-FDG PET/ CT was performed in 47% (N =48) of patients and a metastatic foci was identified in 45.8% of cases (N=22/48). The detection of metastatic foci lead to surgical intervention in a site other than the site of IRI in 38% versus 14% (P < 0.001) in patients undergoing or not 18F-FDG PET/CT respectively. The overall mortality rate was 31.3 % (32/102). The mortality rate was 16.6% (8 /48) and 41.3 % (24/54) in patients undergoing or not 18F-FDG PET/ CT respectively (P=0.03). For IRI, the overall mortality was 9.3 % versus 15.6% in patients undergoing or not 18F-FDG PET/ CT respectively (P<0.001). There was a significant difference in mortality rate at 30 (P=0.001), 90 days (Pā€“0.01) and one year (Pā€“0.004) between patients undergoing or not 18F-FDG PET/ CT respectively. In bivariate analysis, the overall, 30, 90 days and one year mortality rate was significantly reduced among patient with kidney failure (P< 0.001), diabetic foot infection (P=0.006), age >70 years (P=0.007) and prosthetic joint or plate infection (P< 0.001) in whom the 18F-FDG PET/ CT was performed.

Conclusions

Mortality rate was reduced in high risk SAB patients undergoing 18F-FDG PET/ CT. The use of 18F-FDG PET/CT reduced mortality in patients with PJI by detecting more metastatic site leading to more aggressive treatment.


E-mail: