View my account settingsIntroduction
We investigated whether grey scale early ultrasonography could be used for the accurate initial diagnosis of non displaced occult scaphoid fractures.
Methods
This is a prospective blind clinical study that includes 36 patients that came to the emergency room with suspected clinical symptoms for scaphoid fracture but negative initial X-ray's. After that, a high resolution ultrasonography (without Doppler) was performed. Both wrists of each patient were examined, for comparison. After 14 days, new X-rays were performed, which compared to the early sonographic results of the patients.
Background
We searched -in transverse ultrasound view- the value of the difference (Delta) between -proximal to the tunnel- CSA (a) and -in the tunnel's inlet- CSA (b) for separating normal from abnormal median nerves.
Methods
51 patients –suspicious for CTS- underwent Phalen and Tinnel tests. After that, we used a high frequency ultrasound to measure CSAa, CSAb and Delta CSA in both hands. 33 of our 51 patients did not experience any clinical symptoms at the contralateral hand, so that we could perform a comparative study of normal and pathological median nerves (on the same patients). Then, all of them completed a Q-DASH questionnaire and a visual analogue scale (VAS 100/100) and they carried through with a nerve conduction study (NCS).
Background
Staphylococcus aureus is a human pathogen involved in implant-related infections. In these diseases, biofilm production is the key pathogenic event, and it increases antibiotic resistance of the organism. Because this phenomenon, local delivery of antibiotics could allows reaching high concentrations in the infected tissue without the secondary effects linked to systemic administration. Here we report the use of a ceramic biomaterial (SBA-15) as a carrier of antibiotics in order to deliver them directly in the infected tissue.
Material and methods
SBA-15 discs were loaded with vancomycin, rifampin and a combination of both according to the protocol described by Molina-Manso et al. Loaded discs were introduced in a 0.5 McFarland suspension of S. aureus 15981 and incubated during 6 and 24 hours in order to develop a biofilm. After incubation, samples were sonicated during 5 minutes and 1:10 serial dilutions were performed in order to count viable bacteria. All experiments were performed in triplicate.
Background
The anterior-posterior (AP) pelvis radiograph is crucial for diagnosis of neck of femur (NOF) fractures, especially as this is one of the commonest fractures in the elderly population. Anecdotally we found that initial AP pelvis radiographs for these suspected fractures did not always exhibit the bones sufficiently. Repeat radiographs were needed, leading to delays in diagnosis, treatment, and repeated radiation exposure. Missed diagnoses can have significant consequences for this patient group. We assessed how many initial AP pelvis radiographs taken for suspected NOF fracture fitted criteria for adequate diagnostic imaging.
Methods
A retrospective study was carried out assessing the initial AP pelvis radiograph done for each patient presenting to our dedicated NOF unit with suspected NOF fracture for 1st June – 31st July 2014. European Guidelines for Diagnostic Imaging were used as the benchmark. Each radiograph was scored out of six, one for each criteria fulfilled. Guidelines deemed images scoring ≤3 as inadequate.
Introduction
Prosthetic joint infections (PJI) occur infrequently, but due to its increased clinical use represent the most devastating complication with high morbidity and substantial cost. Staphylococcus aureus and coagulase-negative staphylococci are the most common infecting agents associated with PJI. A possible therapeutic approach could be the local antibiotic by fluoride-TiO2 nanostructured anodic layers in order to prevent surface colonisation during the early moments after surgery. Here we describe the first results of this model using two common antibiotics.
Methods
Fluoride-TiO2 nanostructured anodic layers on Ti6Al4V alloy were produced as described previously by Arenas et al (2013). Discs shaped pieces of Ti6Al4V alloy were loaded with a solution of 150 mg antibiotic (vancomycin or gentamicin)/20 ml sterile distilled water. Samples were immersed in this solution during 24 hours at room temperature with agitation, and then were dried during 48 hours at 20°C. Antibiotic release was studied by introducing both discs in sterile PBS and samples were taken at different times. Samples were then frozen at −80°C until HPLC measurements and biological activity tests using Bacillus subtilis ATCC 6051 (vancomycin) and Escherichia coli ATCC 25922 (gentamicin) were performed.
Background
Patients presenting to fracture clinic who have had initial management of a fracture performed by Accident and Emergency (A+E) often require further intervention to correct unacceptable position. This usually takes the form of booking a patient for a general anaesthetic to have manipulation under anaesthesia (MUA) or open surgery.
Methods
Prospective data collection over a 6-month period. Included subjects were those that had initial management of a fracture performed by A+E, who went on to require re-manipulation in fracture-clinic. Manipulations were performed by trained plaster technicians using entonox analgesia followed by application of moulded cast. Radiographs were reviewed immediately post-manipulation by treating surgeon and patient managed accordingly. A retrospective review of radiograph images was performed by two doctors independently to grade the outcomes following manipulation.
Background
Patient reported outcomes/experience measures have been a fundamental part of the NHS since 2009. Osteotomy procedures for hallux valgus produce varied outcomes due to their subjective nature. We used PROMS2.0, a semi-automated web-based system, which allows collection and analysis of outcome data, to assess what the patient reported outcome/experience measures for scarf+/− akin osteotomy for hallux valgus are at UHSM.
Methods
Prospective PROMS data was collected from November 2012 to February 2015. Scores used to asses outcomes included EQ-5D VAS, EQ-5D Health Index, and MOxFQ, collected pre-operatively and post-operatively. Patient Personal Experience (PPE-15) was collected postoperatively.
Background
There is a 20% dissatisfaction rate with knee replacements. Calls for tools that can pre-operatively identify patients at risk of being dissatisfied postoperatively have been widespread. However, it is unclear what sort of information patients would want from such a tool, how it would affect their decision making process, and at what part of the pathway such a tool should be used.
Methods
Using focus groups involving 12 participants and in-depth interviews with 10 participants, we examined the effect outcome prediction has by providing fictitious predictions to patients at different stages of treatment. A qualitative analysis of themes, based on a constant comparative method, is used to analyse the data. This study was approved by the Dyfed Powys Research Ethics Committee (13/WA/0140).
Background
Despite an ageing population and a rise in the number of joint replacements being performed, the mean age of patients undergoing surgery remains static. One explanation for this is continued concern over the risks of performing surgery on the very elderly. We aim to investigate the outcome of Total Knee Replacement (TKR) in a nonagenarian population.
Methods
The Elective Orthopaedic Centre, Epsom has an established patient reported outcome measures (PROMs) programme into which all patients are routinely enrolled. We retrospectively reviewed our data set for a cohort of nonagenarians undergoing primary TKR, between April 2008 and October 2011. Post-operative complications, mortality rates and functional outcomes were compared to those of a time matched 70–79 year old cohort. Only patients with a primary diagnosis of osteoarthritis were included whereas an exclusion criterion consisted of patients undergoing revision surgery, simultaneous bilateral replacements or conversion from a Unicompartmental Knee replacement.
Background
Increased revision rates and early failure of Metal-on-Metal (MoM) hip replacements are often due to adverse reaction to metal debris (ARMD). ARMD describes numerous symptoms in patients such as pain, osteolysis and soft tissue damage. Cobalt is a major component of MoM joints and can initiate an immune response via activation of the innate immune receptor Toll-like receptor 4 (TLR4). This leads to increased secretion of inflammatory cytokines e.g. interleukin-8 (IL-8). This study investigates whether TLR4-specific antagonists inhibit the inflammatory response to cobalt using IL-8 gene expression and protein secretion as a marker of TLR4 activation.
Methods
MonoMac 6 (MM6) cells, a human macrophage cell line, were treated with TLR4-specific antagonists followed by 0.75mM of cobalt chloride. Lipopolysaccharide (LPS), a known TLR4 agonist was used as a positive control. Enzyme-linked immunosorbent assay (ELISA) was used to assess IL-8 protein secretion and real time- polymerase chain reaction (RT-PCR) allowed quantification of IL-8 gene expression.
Background
Polytrauma patients are at high risk of systematic inflammatory response syndrome (SIRS) due to an exaggerated unbalanced immune response that can lead to multiple organ failure and increased mortality. This response is often heightened following acute surgical management as a result, damage-control orthopaedics (DCO) was born. This allows the patient to be stabilised using external fixation allowing physiology to improve. This systematic review aims to compare DCO against early total care (ETC) (<24hrs intramedullary nailing) in polytraumatised patients with femoral shaft fractures using a diagnosis of acute lung injury (ALI) as the primary outcome measure.
Method
A systematic review of MEDLINE, EMBASE, CENTRAL and AMED was carried out to identify all English language studies comparing ETC versus DCO using ALI as the primary outcome measure. Two authors independently screened the studies and performed data extraction. Risk of bias was assessed using the Cochrane risk of bias tool and the Risk-of-Bias Assessment Tool for Non-randomised Studies.
Background
Traditionally, a Surgical Tourniquet (ST) is used during Total Knee Replacement Surgery (TKRS) to prevent blood flow to the leg and improve the surgical field of view. The use of a ST is known to increase the risk of venous thromboembolism. Echogenic material, suggestive of emboli has been observed in the brain following ST deflation in TKRS despite the absence of a patent foramen ovale, likely through pulmonary shunts. The aim of this study was to assess whether cerebral emboli result from tourniquet use in TKRS and the sequelae of any emboli.
Methods
11 subjects from a single centre undergoing routine TKRS with a ST gave informed consent. Each participant had diffusion weighted MR brain imaging prior to, and within 48 hours after TKRS and completed pre and post-operative mini-mental state examinations (MMSE).
Background
Total Knee Replacement (TKR) is one of the most common surgeries in our speciality, with a high risk of significant blood loss and consequent transfusion. The drain clamping is usually applied to reduce both blood loss and transfusion in this procedure. However, this method is still somewhat controversial too.
Method
We performed a prospective randomised study of 74 patients with advanced knee osteoarthritis. All were treated in our centre with TKR. The patients were randomly assigned into two groups. In group A we included patients whose drainage system was clamped temporarily (during the first 6 postoperative hours). Group B includes those patients in who we use traditional system, with continuous suction drain that was placed after surgery.
Background
In the adolescent population, operative management of hallux-valgus is controversial. Operations may be less successful than in adults and post-operative recurrence is more common before full skeletal maturity. This study assesses the radiographic, functional and qualitative outcomes of surgical Hallux Valgus correction in adolescents.
Methods
Three independent reviewers retrospectively analysed pre and post-operative radiological markers of hallux valgus severity for 44 operations on patients age 13–18. The patient cohort were also asked the Manchester-Oxford foot questionnaire (MOXFQ) to assess functional outcome via telephone interview and patient notes were reviewed for any evidence of complications.
Background and Aims
Daily senior review is of paramount importance to provide optimal clinical care and facilitate timely discharge. Also, the General Medical Council state in Good Medical Practice 2013 that “work should be recorded clearly, accurately and legibly…containing relevant clinical findings, decisions made and actions agreed”. This audit aims to evaluate whether all trauma and elective Orthopaedic patients at one unit receive a daily senior review, which is fully documented in the case-notes, and whether a Comprehensive Unit-based Safety Programme (CUSP) toolkit can better facilitate this?
Methods
Case-notes for all patients admitted under Trauma and Orthopaedics on three separate non-consecutive days during a two-week period were scrutinized, examining them for the presence of CUSP toolkits and whether these were adequately completed.
Background
Meniscus repair can restore the function of torn meniscus in anterior cruciate ligament (ACL)-reconstructed knees. However, few reports investigate the relationship between concurrent meniscus repair with ACL reconstruction and postoperative meniscal position. This study aimed to evaluate the size of the medial meniscus in patients who underwent ACL reconstruction and concomitant all-inside medial meniscus repair.
Methods
This study received the approval of our Institutional Review Board. Twenty patients underwent ACL reconstruction and concurrent medial meniscus repair of a peripheral longitudinal tear using the FasT-Fix meniscal repair device. Medial tibial plateau length (MTPL) and width (MTPW) were determined by radiographic images. We evaluated the Lysholm score, anteroposterior instability (difference in KT-2000 arthrometer measurement), meniscal healing, and magnetic resonance imaging (MRI)-based medial meniscal length (MML) and width (MMW). The healing status of repaired medial meniscus was assessed by 2nd-look arthroscopy.
Background
We prospectively studied achilles tendon acute rupture cases operated over 2 years and reviewed the causes, treatment options, outcome and complications. Our Aim of the study was to look at the different suture materials used and to observe for their complications.
Method
Fifty-three (53) consecutive patients who came to our hospital with acute Achilles rupture were included. We prospectively collected their data, including medical history, causes, mode of treatment and complications. We followed them up to 6 months to measure their outcome using Boyden score and observe any complications.
Background
We herein report a case of isolated hip pain in a four year old boy. The unique aspect of this case study is the unusual history, presentation, ultrasonography, MRI and blood culture results, which lead to the diagnosis and treatment of adductor pyomyositis with a rare organism (Streptococcus Mitis) in a temperate country. The objectives of this case study is to discuss the key learning outcomes with respect to assessment and management of this case.
Methods
The patient presented with a one day history of malaise, fever, left groin pain and inability to weight bear on the left leg. There was no history of any trauma, predisposing infections or recent travel. A working diagnosis of transient synovitis / septic arthritis of the hip was made on clinical examination.
Background
Medical applications of nanotechnology are promising because it allows the surface of biomaterial to be tailored to optimise the interfacial interaction between the biomaterial and its biological environment. Such interfaces are of interest in the domain of orthopaedic surgery as they could have anti-bacterial functions or could be used as drug delivery systems. The development of orthopaedics is moving towards better integration of biology in implants and surgical techniques, but the mechanical properties of implanted materials are still important for orthopaedic applications. During clinical implantation, implants are subjected to large mechanical stresses. In order to obtain the best performance during clinical use, mechanical properties of implants need to be investigated and understood.
Method
We modified the topography of commercial titanium orthopaedic screws using electrochemical anodization in a 0.4 wt% hydrofluoric acid solution to produce titanium dioxide nanotube layers. The morphology of the nanotube layers were characterised using scanning electron microscopy. The mechanical properties of the nanotube layers were investigated by screwing and unscrewing an anodized screw into several different types of human bone while the torsional force applied to the screwdriver was measured using a torque screwdriver. The range of torsional force applied to the screwdriver was between 5 and 80 cN·m. Independent assessment of the mechanical properties of the same surfaces was performed on simple anodized titanium foils using a triboindenter.
Background
Devices are frequently used to gain sufficient purchase in a bone so that the bone itself can be manipulated to move or rupture soft tissue attachments. During hip surgery, several different extraction corkscrews are available to remove the femoral head, each with a different screw design with no evidence to suggest which is most effective. Additionally during the use of corkscrew devices, often due to the low bone density, stripping of the screw threads out of the femoral head can occur prior to its extraction, thus requiring reinsertion. The aims of this project were to measure the primary pullout and reinsertional forces of five commercially available corkscrews.
Methods
Polyurethane bone models covering a spectrum of osteoporotic to normal bone densities (0.08 gcm-3, 0.16 gcm-3 and 0.32 gcm-3) were used in axial tensile testing at two insertional depths to assess the maximum pullout force of these corkscrews (Zimmer, Stryker, Medacta, JRI, Depuy).
Background Hip fractures are one of the leading causes of hospital admissions. Surgical treatment is often associated with significant blood loss, requiring post-operative erythrocyte transfusion. Aim To assess post-operative erythrocyte transfusion rates for hip fractures and evaluate the effect of tranexamic acid (TXA).
Method
All patients undergoing surgical repair of a hip fracture at RLBUHT between 1st April 2013 – 30th April 2014 were selected. Data regarding transfusion status and peri-operative TXA use was collected from electronic databases and case notes.
Results
450 patients were admitted with a hip fracture, of whom 441 underwent surgery. Modalities of hip fixation included total hip replacement (THR, n=39), hemiarthroplasty (n=145), dynamic hip screw (DHS, n=116), cannulated hip screw (CHS, n=17) and long (n=71) and short (n=53) intramedullary hip screw (IMHS). 44.2% received a post-operative erythrocyte transfusion, with an average of 2.5 units per patient (range 1–9 units). With all study subjects included, the average transfusion rates for THR, hemiarthroplasty, DHS, CHS, long IMHS and short IMHS were 0.44 units, 0.78 units, 0.97 units, 0.47 units, 1.55 units and 1.19 units respectively. Data regarding intra-operative TXA administration was available for 318 (72.1%) patients, sixty-one of whom received TXA. 27.9% given TXA required a post-operative transfusion (range 0–6 units), compared to 35.4% of patient with no intra-operative TXA (range 0–11 units), p=0.142.
Background
Surgical management of calcaneus fractures is demanding and has a high risk of wound complications. Traditionally these fractures are managed with splinting until swelling has subsided. We describe a novel protocol for the management of displaced intra-articular calcaneus fractures utilising a temporizing external fixator and staged conversion to plate fixation through a sinus tarsi approach. The goal of this technique is to allow for earlier treatment with open reduction and internal fixation, minimise the amount of manipulation required at the time of definitive fixation and reduce the wound complication rate seen with the extensile approach.
Methods
The records of patients with displaced calcaneus fractures from 2010–2014 were retrospectively reviewed. A total of 10 patients with 12 calcaneus fractures were treated with this protocol. All patients underwent ankle-spanning medial external fixation within 48 hours of injury. Patients underwent conversion to open plate fixation through a sinus tarsi approach when skin turgor had returned to normal. Time to surgery, infection rate, wound complications, radiographic alignment, and time to radiographic union were recorded.
Introduction
The stability of the elbow joint following an acute elbow dislocation is dependent on associated injuries. The ability to identify these concomitant injuries correctly directs management and improves the chances of a successful outcome. Interpretation of plain radiographs in the presence of either a dislocation or post-reduction films with plaster in-situ is difficult. This study aimed to assess the ability of orthopaedic registrars to accurately identify associated bony injuries on initial plain radiographs using CT as the gold standard for comparison.
Methods
Patients over the age of 16 years undergoing an elbow CT scan within one week of a documented elbow dislocation between 1st June 2010 and 1st June 2014 were included in the study. Three orthopaedic registrars independently reviewed both the initial dislocation and immediate post reduction plain radiographs to identify any associated bony injuries. This radiograph review was repeated by each registrar after two weeks. The incidence of associated injuries as well as the inter- and intra-observer variability was calculated.
Background and Aims
Many orthopaedic patients admitted to hospital who require urgent surgery are also on Warfarin. Patients with an INR>2 have an increased risk of bleeding complications during surgery; however delay to surgery due to a high INR has both clinical and financial implications. This audit evaluates whether the appropriate management for correction of INR is employed as per local guidelines and, if not, whether this results in significant delay to operative treatment.
Methods
A retrospective and prospective audit was performed analysing all Orthopaedic trauma admissions admitted to University Hospital Aintree in a 5 month period. Only those solely on warfarin, who were not acutely bleeding and required surgery in <24 hours were included.
Background
Comminuted fractures involving the tibia are associated with a high level of complications including delayed healing and non-union, in conjunction with dramatically increased healthcare costs. Certain clinicians utilise a Pixel Value Ratio (PRV) of 1 to indicate such fracture healing. The subjectivity of this method has led to mixed outcomes including regenerate fracture. The poor prognosis of complex load bearing fractures is accentuated by the fact that no quantitative gold standard currently exists to which clinicians can reference regarding the definition of a healed fracture. The aim of the current study is to use patient specific finite element analysis of complex tibial fractures treated with Ilizarov frames to demonstrate callus maturation and to determine the optimum frame removal time.
Methods
3 patients (2 males, 1 female) were analysed following presentation with complex tibial fractures treated with Ilizarov frames. Patient specific computational analysis was performed according to radiographic data, incorporating maturing material properties to analyse the callus response to weight bearing over the healing timeframe. Computational results were compared to the PVR method to evaluate its efficacy in determining the optimum Ilizarov frame removal time.
Background
Due to their tailored porous texture, breathability and flexibility, carbon cloths (CCs) are good scaffolds for biomedical application. However, biocompatibility of CCs depends on their physic-chemical properties. Calcium phosphate ceramics (CaP) are well known for their use in orthopaedic field. So, carbon cloth-reinforced CaP composites are promising bioceramic materials for bone regeneration.
Methods
CaP coating are performed using sono-electrochemical deposition method. The electrolyte consisted in an aqueous solution of calcium and phosphates precursors. CC was used as work electrode in three-electrode system. SEM, TEM, XRD, 1H and 31P MAS NMR and FTIR spectroscopies were performed to characterise the deposits. In vitro biocompatibility of CCs with and without coatings is tested with human osteoblasts.
The Cobb Stainsby forefoot arthroplasty for claw and hammer toes combines excision arthroplasty (Stainsby) with extensor tendon transfer to the metatarsal head (Cobb). We present a retrospective, three surgeon case series of 218 toes in 128 patients over four years. Clinical notes were reviewed for all patients and 77 could be contacted for a telephone survey. Follow up ranged from 12–82 months.
All patients presented with pain and shoe wear problems from dislocated metatarsophalangeal joints either from arthritis, hallux valgus, Freiberg's disease or neurological disorders. Ipsilateral foot procedures were performed simultaneously in 24 (30%) patients. Seventy-two patients (94%) were satisfied, 72 (94%) reported pain relief, 55 (71%) were happy with toe control, 61 (79%) were pleased with cosmesis, 59 (77%) returned to normal footwear and 56 (73%) reported unlimited daily activities. Minor complications occurred in 17 (13%) and 3 (2%) developed complex regional pain syndrome. Four (5%) developed recurrent clawing.
The Stainsby procedure permits relocation of the plantar plate under the metatarsal head for cushioned weight-bearing but can create a floppy, unsightly toe. By combining this with the Cobb procedure, our case series demonstrates improved outcomes from either procedure alone with benefits over alternatives such as the Weil's osteotomy.
Oxford Level 4 evidence – retrospective case series.
Background
Intracapsular neck of femur fractures are one of the most common injuries seen in Orthopaedics. When the fracture is amenable to internal fixation there are 2 main treatment options, namely multiple cannulated hip screws (MCS) and 2-hole sliding hip screws (SHS). In this retrospective study we examine the outcomes associated with these two methods of internal fixation. At present there is little consensus regarding which treatment should be used
Methods
161 patients were found to have suffered intracapsular neck of femur fracture treated with either SHS or MCS fixation over a 5 year period from April 2009 to April 2014, allowing at least 1 year follow up following injury. The patients imaging and clinical notes were then reviewed to ascertain the outcome of their treatment and any complications.
Introduction
We compared ultrasound guided methylprednizolone-lidacaine infiltrations around inflammatory area of plantar aponeurosis with systematic use of NSAID'S. Also, we investigated the reliability of the sonographic criteria (a. swelling of aponeurosis more than 20% in comparison to the healthy foot, b. effusion around aponeurosis, c. calcium deposits) most used to identify plantar fasciitis in clinically suspicious patients.
Methods
A prospective randomised controlled clinical trial, including 28 patients (mean age: 47 years, range: 36–65 years, 85% females) with typical clinical symptoms of plantar fasciitis. All of these patients undertook a soft tissue ultrasonography of the plantar aponeurosis, without Doppler. Then, we randomly divided our sample in 2 groups, group A (14 patients) and group B (14 patients). In group A patients we performed an ultrasound guided injection –in transverse view- around the swollen part of aponeurosis, while we managed group B patients with per os NSAID's treatment (meloxicam 15 mg, once per day) for 2 weeks.
Background
To determine if double needle ultrasound-guided hydrodissolution and aspiration of intratendinous calcification is more effective treatment than blind subacromial corticosteroid injection.
Methods
A prospective randomised comparative clinical study of 32 patients suffering from chronic symptomatic calcific tendinosis of the supraspinatous tendon. Group A (16 patients) received a double needle ultrasound-guided aspiration of the calcification, while group B (16 patients) underwent a blind subacromial betamethazone injection. As far as group A, we attached a syringe in the first needle, including 10cc. of normal saline (N/S), that we injected targeting the calcium deposit. Then we tried to achieve consecutive aspirations through the second needle.
Background
PROMS and PREMS are a fundamental and essential part of the NHS. Chilectomy and fusion procedures for hallux rigidus produce varied outcomes due to their subjective nature. PROMS2.0, a semi-automated web-based system, which allows collection and analysis of outcome data, to compare what PROMS/PREMS for chilectomy/fusion for hallux rigidus are at UHSM including variance across osteoarthritis grades.
Methods
Data was collected from March-2013 to December-2014. Scores used to assess outcomes included EQ-5D-VAS, EQ-5D Health-Index, and MOxFQ, collected pre-operatively and post-operatively. Patient-Personal-Experience (PPE-15) was collected postoperatively. Data was compared.
Background
Hyaluronic acid (HA) hydrogels are becoming an increasingly attractive choice for the creation of new biomaterials useful in wound care, tissue engineering and regenerative medicine, because of their high level of biocompatibility and biodegradability, and for their ability to imitate the environment of the extracellular matrix (ECM). Due to the poor biomechanical properties of native hyaluronan, a variety of chemical modifications have been devised to provide mechanically and chemically stiffer materials.
Methods
In this work, 200 kDa hyaluronic acid was modified with coumarin moieties via a functional linker (FID119) and photo-polymerised into networks through a [2+2] cycloaddition reaction using near-UV light (lmax=365 nm). This method allows to obtain “wall-to-wall” hydrogels starting from moderately viscous solutions. FID119 can therefore be deposited in the cartilage defect as an aqueous solution and can be polymerised in situ after UV irradiation.
Background
Clavicle development occurs before the age of 9 in females and 12 in males. Children below the age of 10 with displaced midshaft clavicle fractures recover well with conservative management. However adolescents are more demanding of function and satisfaction following clavicle fractures and may benefit from operative management. Study aims: 1) Perform a systematic review of the current evidence supporting intramedullary fixation of adolescent clavicle fractures. 2) Review current management in a major trauma center (MTC) with a view to assess feasibility for a randomised controlled trial (RCT).
Methods
The MEDLINE, EMBASE and AMED databases were searched in October 2014 to identify all English language studies evaluating intramedullary fixation in children aged 10–18 years using MeSH terms. Data was extracted using a standardised data collection sheet and studies were critically appraised by aid of the PRISMA checklist. All patients aged 9–15 attending an MTC receiving clavicle radiographs in 2014 were retrospectively reviewed for type of fracture, management and outcome.
Background
A new knee simulator has been developed at Ghent University. This simulator provides the unique opportunity of evaluating the knee kinematics during activities of daily living. The simulator therefore controls the position of the ankle in the sagittal plane while keeping the hip at a fixed position. This approach provides full kinematic freedom to the knee. To evaluate and validate the performance of the simulator, the development of and comparison with a numerical simulation model is discussed in this paper.
Methods
Both a two and three dimensional simulation model have been developed using the AnyBody Modelling System (AMS). In the two dimensional model, the knee joint is represented by a hinge. Similarly, the ankle and hip joint are represented by a hinge joint and a variable amplitude quadriceps and hamstrings force is applied. In line with this simulation model, a hinge model was created that could be mounted in the UGent knee simulator to evaluate the performance of the simulated model. The hinge model thereby performs a cyclic motion under varying simulated muscle loads while recording the ankle reaction forces. In addition to the two dimensional model, a three dimensional model has been developed. More specifically, a model is built of a sawbone leg holding a posterior stabilised single radius total knee implant. The physical sawbone model contains simplified medial and lateral collateral ligaments. In line with the boundary conditions of the UGent knee simulator, the simulated hip contains a single rotational degree of freedom and the ankle holds four degrees of freedom (three rotations, single translation). In the simulations, the knee is modelled using the force-dependent kinematics (FDK) method built in the AMS. This leaves the knee with six degrees of freedom that are controlled by the ligament tension in combination with the applied quadriceps load and shape of the implant. The physical sawbone model goes through five cycles in the UGent simulator using while recording the kinematics of the femur and tibia using a set of markers rigidly attached to the femur and tibia bone. The position of the implant with respect to the markers was evaluated by CT-scanning the sawbone model.
Background
The traditional Kocher approach for lateral elbow exposure is often complicated by injury to the posterior interosseous nerve (PIN) and the lateral ulnar collateral ligamentous (LUCL). Kaplan approach is less commonly used, due to its known proximity to the PIN. Extensor Digitorum Communis (EDC) splitting approach allows possible wide surgical exposure and low risk of LUCL damage. The comparison of PIN injury during surgical dissection among these 3 common lateral approaches was not previously evaluated. We aim to determine the anatomical proximity of the PIN in these 3 common lateral elbow approaches and to define a safe zone of dissection for the surgical exposure.
Methods
Cadaveric dissections of 9 pairs of fresh frozen adult upper extremities were performed using EDC splitting, Kaplan and Kocher approach to the radial head sequentially in a randomised order. The radial head and PIN were exposed. A mark was made on the radial head upon the initial exposure during dissection. Measurements from the marked point of the radial head to the PIN were made. Study has been approved by the ethics committee.
Background
The Targon FN plate is a combination of the sliding hip screw and multiple cancellous screws. It is used in the fixation of intracapsular fractures of the neck of femur. The aim of this prospective audit was to assess clinical and radiological outcomes of Targon FN.
Method
All patients who had a Targon FN fixation over a period of 18 months at a district general hospital were included. A pro forma was completed using medical records, including x-ray images.
Background
Proximal femoral fracture is a common, major health problem resulting in loss of functional independence and a high cost burden on society. Rehabilitation can potentially maximise functional recovery, but evidence of effectiveness is lacking. An enhanced rehabilitation intervention designed to improve self-efficacy and increase the amount and quality of practice of physical exercise and activities of daily living has been developed consisting of patient held workbooks and extra therapy sessions in the community. This study aims to define characteristics of the cohort of individuals this intervention is targeted to, assess acceptability of the intervention and feasibility of recruiting participants for a larger scale trial.
Methods
An anonymous cohort study of all proximal femoral fracture patients admitted to three acute hospitals will provide details on residence pre-admission, type of fracture, type of surgery, adverse events and subsequent readmissions. A separate randomised feasibility study recruiting participants from this cohort will assess acceptability and feasibility of the study in terms of eligibility, recruitment, reasons for decline, retention and outcome measure completion. The success rate of identifying patients for the feasibility study and whether the recruited participants are representative of the cohort population will be evaluated by comparison of the feasibility participant screening and background data with that of the cohort.
Background
The advantages of treatment by open reduction and internal fixation for intertrochanteric fractures of the proximal femur have been well known for several decades. Failure of fixation can result in revision surgery, prolonged inpatient stay and has major socio-economic consequences. There are many new devices on the market to help deal with this problem. Expandable hip screw (EHS) is one such device, which is an expanding bolt that may offer superior fixation in osteoporotic bone compared to the standard dynamic hip screw (DHS) type device.
Methods
Static axial compression tests with elastic deformation of the specimens were performed with a crosshead speed of 10 mm/min to determine stiffness of testing was performed with 3 cycles from 0 N to 250 N, 3 cycles from 0 N to 500 N, 3 cycles from 0 N to 750 N and 3 cycles from 0 N to 1000 N with a holding time of 10 s per test cycle. Displacement control was apply the pullout strength with a velocity of 1mm/sec. The ability to resist rotation about the axis of a lag screw is of critical importance particularly when the fracture line is perpendicular, or nearly perpendicular, to the femoral neck. Implants were subjected to a rotation of 1 degree/sec and peak torque values were recorded.
Adverse reaction to metal debris (ARMD) is well recognised as a complication of large head metal on metal total hip replacement (THR) leading to pain, bone and tissue loss and the need for revision surgery. An emerging problem of trunnionosis in metal on polyethylene total hip replacements leading to ARMD has been reported in a few cases. Increased metal ion levels have been reported in THR's with a titanium stem and a cobalt chrome head such as the Accolade-Trident THR (Stryker).
We present 3 cases of ARMD with Accloade-Trident THR's with 36mm cobalt chrome head and a polyethylene liner. Metal ion levels were elevated in all three patients (cobalt 10.3 – 161nmol/l). Intraoperative tissue samples were negative for infection and inflammatory markers were normal. Abnormal fluid collections were seen in all three cases and bone loss was severe in one patient leading to a proximal femoral replacement. Histology demonstrated either a non-specific inflammatory reaction in a case which presented early or a granulomatous reaction in a more advanced case suggesting a local foreign body reaction. All patients had improved symptoms post-operatively. 1 patient who had staged bilateral Accolade-Trident THR's required revision of both THR's.
ARMD in metal on polyethylene THR's with a titanium stem represents a potential emerging problem. Further studies are required to assess whether these occurrences are rare or represent the tip of an iceberg.
Aim
Smartphone applications have a great scope for revolutionising the medical field and are becoming increasingly utilised in clinical practice. They are advantageous as they are timesaving and readily available at the touch of a button. We reviewed all the T&O clinically relevant applications available for doctors on Apple's ‘App Store’.
Methods
A search was performed using the following terms: Trauma, Orthopaedics, Ortho, Musculoskeletal and Fracture. Applications that were in any language other than English were excluded. The applications were subsequently categorised into: ‘clinical’, ‘learning and reference’, ‘hospital guidelines’ and ‘patient education’.
Background The internet is an increasingly utilised resource for accessing information regarding a variety of heath conditions. YouTube is a popular video sharing platform used to both seek and distribute information online.
Materials & Methods
A search for ‘scoliosis’ was carried out using YouTube's search engine and data was collected on the first fifty videos returned. A JAMA score (to determine currency, authorship, source and disclosure) and scoliosis specific score (that measures the amount of information on the diagnosis and treatment options as devised by Mathur et al in 2005; scored 0–32) was recorded for each video to measure quality objectively. Additionally the number of views, number of comments and feedback positivity was documented for each. Data analysis was conducted using R 3.1.4/R Studio 0.98 with control for the age of each video in analysis models.
Results
The average number of views per video was 71,152 with an average length of 7 minutes 32 seconds. Thirty six percent of the videos fell under the authorship category of personal experience. The average JAMA score was 1.32/4 and average scoliosis specific score was 5.38/32. There was a positive correlation between JAMA score and number of views P=0.003. However in contrast there was a negative correlation between scoliosis specific score and number of views P=0.01.
Background
To investigate the new theory of hydroneurolysis and hydrodissection in the treatment of carpal tunnel syndrome (CTS). Independently of the fluid hydrodissolution works due to mechanical forces and it may have some positive effects in patients with ischemic damage caused by scar tissue pressure at the nerve's surface.
Methods
A prospective blind clinical study of 31 patients suffering from carpal tunnel syndrome, established by nerve conduction studies and clinical tests. 14 patients (out of 29), who refused to undergo an open operation as a treatment to their disease at this point of time, were treated with a simple ultrasound-guided injection at the proximal carpal tunnel. In order to exclude the biochemical influence of the fluid in the treating disease we choosed to infiltrate 3 cc. of normal saline 0,9%. In the follow-up period our group was asked to answer to a new Q-DASH score and visual analogue scale (VAS) 100/100 in 2, 4 and 8 weeks.
Background
The approach to Intramedullary (IM) fixation of long bone fractures remains a controversial issue. Early reports demonstrated less favourable results of retrograde nailing as compared with antegrade options due to higher non-union rates. The aim of this audit was to evaluate the outcomes of practice within the Trauma and Orthopaedic department with relation to IM nail fixation of diaphyseal femur fractures.
Methodology
The Trauma database between February 2010 and September 2013 was used to identify all femur IM nailing procedures. Picture Archiving and Communication System (PACS) software was used to classify the fractures according to the Muller AO classification. All 3–2 (Diaphyseal femur fractures) were included in the audit. PACS imaging together with outpatient documentation was evaluated for radiological and clinical outcome.
Background
This survey was conducted to gain information about how surgeons use scientific literature and how this is influenced by their knowledge of evidence-based medicine. The results were compared to a survey conducted 10 years previously. Where appropriate, the same questions as in the 2003 survey were used.
Methods
We administered a voluntary questionnaire to participants at the AO Foundation courses in Davos, Switzerland, in December 2013. We surveyed, amongst other topics, the surgeons’ levels of education in Evidence-Based Medicine (EBM), how they implement EBM in daily practice and their publication record.
Background
The economic crisis has significantly altered the quality of life in Greece. The obvious negative impact on the offered social and health services has been adequately analysed. We aimed to determine whether the economic crisis has influenced the quantity and quality of Orthopaedic research in Greece, as mirrored from the papers presented at the annual meetings of Hellenic Association of Orthopaedic Surgery between the years 2008–2014.
Methods
The abstracts of the papers (oral and posters) presented in these meetings have been examined. Details regarding the department of origin were registered. We determined the level of evidence (according to the AAOS classification system), found the amount of papers that were published in PubMed journal and noted if a department of another country participated.
Background
Fractures of the femoral neck occurring outside the capsule of the hip joint are assumed to have an intact blood supply and hence their conventional management is by fixation rather than arthroplasty. The dynamic hip screw and its variants have been used over many years to fix such fractures but have inherent vulnerabilities; they require an intact lateral femoral cortex, confer a relatively long moment arm to the redistribution of body weight and may cause a stress riser due to the plate with which they are fixed to the femur. Intramedullary devices for fixation of proximal femoral fractures have a shorter moment arm, can be distally locked with reduced perforation of the femoral cortex and are believed to be inherently more stable. For these reasons, a number of surgeons believe them to be superior to the DHS for all extracapsular fractures and their use is now widespread. In this study, we present the usage trends of both devices in extracapsular fractures over the last five years and set these results in the context of patient demographics.
Methods
Our departmental electronic patient management system was used to identify all patients undergoing surgery coded as either DHS or its variants or intramedullary fixation of hip fracture. The patients’ age, sex and American Society of Anaesthesiologists grading were recorded. Comparison between groups was made using appropriate tests in SPSS.
Background
Tourniquets are routinely used in total knee arthroplasty (TKA) with an estimated use by up to 93% of surgeons. Advantages include the ability to provide a bloodless field of view to facilitate cement application and increase the success of the procedure. Overall reduction in blood loss is another perceived advantage, however recent research has demonstrated no measurable reduction and conversely a substantial increase in complications such as deep vein thrombosis and systemic emboli. Given the significant complications of tourniquet use we aim to identify patients’ views on tourniquets and of emphasis their awareness of the possible risks involved prior to the procedure.
Method
A questionnaire-based study was carried out on 35 patients attending an elective orthopaedic centre for TKA surgery. Ethical approval was granted by NRES committee – East of England (REC Ref: 14/EE/1265). Patients were provided with an information sheet detailing the reasons for the tourniquet use and the associated risks and benefits. They were then provided with a questionnaire to ascertain their views and previous understanding of the subject. Simple statistical measures were implemented to analyse the data.
Background
Calcium sulfate and phosphate have a long clinical history of use as bone-void fillers (BVF) with established biocompatibility and resorption profiles. It has been widely reported that the addition of ‘impurity’ elements such as Silicon, Strontium and Zinc to calcium phosphate is advantageous, resulting in an improved bone healing response.
Methods
This study examined the in vivo response of two formulations of calcium sulfate, as 3mm diameter hemispherical beads, in critical sized defects created in cancellous bone of distal femur and proximal tibia (10mm diameter × 13mm depth) in adult sheep; beads prepared from recrystallised pharmaceutical grade calcium sulfate (RPCS, Stimulan, Biocomposites Ltd, UK) and a lower purity medical grade material containing 1% strontium (SrCS). The animals were sacrificed at 3, 6 and 12 weeks post implantation and the surgical sites analysed using microCT and decalcified histology.
The ability to pre-clinically evaluate new cartilage substitution therapies in viable physiological biotribological models, such as the femoral-tibial joint would be advantageous. Methods for osteochondral (OC) plug culture have been developed and the aim of this study was to extend these methods to organ culture of whole femoral condylar and tibial osteochondral tissues.
Porcine femoral condyles and tibial plateau were aseptically dissected. The majority of cancellous bone was removed leaving intact cartilage and a layer of cortical bone. OC plugs were from porcine knee condyles. “Whole joint” tissues and OC plugs were cultured in defined medium and the viability of the cartilage at day 0, 8 or 14 days of culture assessed by XTT assay and LIVE/DEAD staining. Histological analysis (H&E; alcian blue staining) was used to determine cell number and visualise glycosominoglycans (GAGs). GAG levels were quantified in the cartilage using the dimethylene blue assay.
XTT conversion by OC plug cartilage reduced significantly between day 0 and day 8 with no further change between day 8 and 14. GAG levels did not change. “Whole joint” tissue behaved similarly with reduced XTT conversion between days 0 and 8 (femoral only) and days 0 and 14 (femoral and tibial). LIVE/DEAD staining showed the majority of cells remained alive in the mid and deep cartilage zones. There was a band of mainly dead cells in the surface zone, from day 0. There was no change in the GAG levels over the 14 day culture period.
In conclusion, large cuts of femoral and tibial osteochondral tissues were maintained in organ culture for extended periods. Surface zone chondrocytes rapidly lost membrane integrity ex-vivo whereas mid- and deep zone chondrocytes remained viable. It is hypothesised that physiological loading in a novel physically interactive bioreactor will improve the viability and will be the focus of future studies.
Background
Best practice tariff (BPT) for hip fracture was introduced in April 2010, offering financial incentive to encourage trusts to implement best practice and improve quality of care. This equates to £1335. An early indicator of a patient's outcome is the time to operation from admission, with best practice targets of <36hours as a key marker of quality. As well as being detrimental to patient experience, delays in the time to operation have clear links to increased mortality rates.
Method
We performed a retrospective audit of neck of femur fracture patients from 01.01.14 for 12 months, investigating time to theatre, other BPT targets, and attainment of BPT. A cost analysis was also performed from financial data.
Aim
The aim of this study is to outline the steps and techniques required to create a patient specific 3D printed guide for the accurate placement of the origin of the femoral tunnel for single bundle ACL reconstruction.
Introduction
Placements of the femoral tunnels for ACL reconstruction have changed over the years. Most recently there has been a trend towards placing the tunnels in a more anatomic position. There has been subsequent debate as to where this anatomic position should be. The problem with any attempt at consensus over the placement of an anatomic landmark is that each patient has some variation in their positioning and therefore a fixed point for all has compromise for all as it is an average. Our aim was to attempt to make a cost effective and quick custom guide that could allow placement of the center of the patients’ newly created femoral tunnel in the mid position of their contralateral native ACL femoral footprint.
Background
Numerical modelling using Finite Element (FE) Analysis has become ubiquitous in orthopaedic biomechanics, with both commercial and freely available packages widely used. Three FE packages in particular have gained popularity: Abaqus (Simulia); Ansys (ANSYS, Inc.) and FEBio (University of Utah). Although FEBio is now well established, its developers advise that comparisons should be made against more extensively tested software before trusting its results for specific problems. The aim of the study to conduct a comparison of mesh convergence and to provide validated open-source models of the femur for use all three FE packages.
Methods
Three-dimensional FE models of the femur were created in Abaqus. To ensure that all aspects of the models were identical, custom scripts were developed to import the models into other packages. Mesh convergence studies were conducted for each solver using seven mesh densities for linear tetrahedral elements (up to 2 million). Experimental validation used fourth generation Sawbones composite femurs (n=8) with surface strains measured at four locations. The loading applied at the hip was the averaged peak joint reaction force during walking (Bergman et al); experimentally, this loading vector was used for a reduced load of 500N.
Background
Treating fractures is expensive and includes a long post-operative care. Intra-articular fractures are often treated with open surgery that require massive soft tissue incisions, long healing time and are often accompanied by deep wound infections. Minimally invasive surgery (MIS) is an alternative to this but when performed by surgeons and supported by X-rays does not achieve the required accuracy of surgical treatment.
Methods
Functional and non-functional requirements of the system were established by conducting interviews with orthopaedic surgeons and attending fracture surgeries at Bristol Royal Infirmary to gain first-hand experience of the complexities involved. A robot-assisted fracture system (RAFS) has been designed and built for a distal femur fracture but can generally serve as a platform for other fracture types.
Background
A dedicated referral pathway for patients with bony metastases was introduced at Guy's and St Thomas’ Hospitals (GSTT) in 2009. The aim was to facilitate prompt, consultant-led decision-making and intervention for patients at risk of pathological fracture of long bones.
Methods
We performed a clinical audit and service evaluation of the referral pathway through retrospective review of referrals over 3.5 years.
Background
It is hypothesised that good torsional resistance of the acetabular cement mantle can increase the stability and longevity of cemented THR. Surgeons aim to achieve this by drilling keyholes (KH) in the acetabulum for the cement to penetrate. This study aims to reduce the surgical variability by investigating the influence of KH diameter on torsional resistance for a range of acetabular diameters.
Methods
Three most common diameters of acetabula were tested (50, 54 and 58 mm) to compare three types of KHs: A) 3 × 12 mm diameter, 120° apart, 6 mm deep blind holes; B) 6 × 6 mm diameter, 60° apart, 6 mm deep blind holes; C) 6 × 6 mm diameter, 60° apart, through holes.
An anatomically accurate experimental rig to simulate the implanted acetabulum was used, it allowed the torque strength of a cement mantle to be measured. The cups were cemented into the rig to create a 4 mm mantle and left to cure for 24 h at room temperature. Each sample was tested in the torque rig by applying a ramp displacement at 1.5 °/min until failure. The test was repeated four times for each acetabulum-keyhole combination. Peak torque was used for quantifying torsional resistance.
Background
Metal-on-metal hip implants can produce adverse tissue reactions to wear debris. Increased metal ion concentrations in the blood are measured as a proxy to wear and the complications it can trigger. Many studies have examined various factors influencing the metal ion concentrations. This is the first study to investigate the effect of physical activity level, as objectively measured in daily life, on blood ion levels, expecting higher concentrations for higher patient activity.
Methods
Thirty-three patients (13F/20M, 55.8 ± 6.2 years at surgery) with a unilateral resurfacing hip prosthesis were included. At last follow-up (6.8 ± 1.5 years) cobalt and chromium concentrations in the blood were determined by inductively coupled plasma mass spectrometry. Physical activity was measured during 4 successive days using a 3D-acceleration-based activity monitor. Data was analysed using validated algorithms, producing quantitative and qualitative parameters. Acetabular cup position was measured radiographically. Correlations were tested with Pearson's r'.
Background
Hip arthroplasties are associated with high postoperative pain scores. In some reports, moderate to severe pain was 58% on the first day postoperatively in total hip replacements (THRs). Several techniques are currently used at our institution to tackle acute pain following THRs. These include: 1) Spinal anaesthetic (SA) with Diamorphine only; 2) General anaesthetic (GA) only; 3) SA with local infiltration anaesthetic mixture 1 (LIA1,). Mixture 1 consisted of ropivacaine, adrenaline, and ketorolac; 4) SA with LIA mixture 2 (LIA2). Mixture 2 consisted of bupivacaine and adrenaline; 5) SA with LIA1 and PainKwell pump system. In this study we report on the techniques of acute pain control following THR at our regional centre for elective primary THRs.
Methods
Between June 2011 and July 2014, 173 consecutive patients undergoing primary THR using the posterior approach were prospectively followed up. Group 1. GA only. 31 patients, Group 2. SA only. 37 patients, Group 3. SA plus LIA1 only. 38 patients, Group 4. SA plus LIA2 only, 34 patients, Group 5. SA plus LIA1 plus PainKwell Pump System for 48 hours. 33 patients.
Background
Avulsion fractures of the base of the fifth metatarsal are some of the commonest foot injuries. The robust scientific evidence on the optimal non-operative treatment of these fractures is scant. We designed and conducted a prospective randomised non-inferiority controlled trial of symptomatic treatment versus cast immobilisation with the null hypothesis that cast immobilisation gave substantial benefit over the symptomatic treatment in terms of patient reported outcome measures(PROMs). The alternative hypothesis was that symptomatic treatment was not inferior.
Methods
The primary outcome was the validated Visual Analogue Scale Foot and Ankle (VAS FA) score ranging from 0 to 100. The non-inferiority boundary was set at −10 points. Power sizing determined a minimum of 12 patients per group. Anticipating a significant loss to follow up, 60 patients of 16 years of age or older were randomised to receive either below knee walking cast immobilisation (n = 24) or symptomatic double- elasticated bandage (n = 36) for 4 weeks. Secondary outcome measures were EuroQol-5D, and American Orthopaedic Foot and Ankle Society scores. Data was analysed at the baseline, 4 weeks, 3 months and 6 months post injury by a clinician blinded to a treatment arm.
Background
Visual representation help make the ever-increasing data more attractive, thought provoking and informative. In the field of surgical training, Procedure Based Assessment is a structured method of assessing surgical performance and skills of trainees in the UK and is a valuable tool for trainers in the Annual Review of Competence Progression. Trainers can view PBA's on the online-based Intercollegiate Surgical Curriculum Programme individually in a long-form format with no visual representation.
Aim
To assess the effect of an originally devised EVR tool of PBA's in the context of ARCP on 10 aspects including speed of assessment, assimilation of data, ease of interpretation and identification of trainees’ weaknesses and strengths.
Background
To complement subjective patient-reported outcome measures, objective assessments are needed. Activity is an objective clinical outcome which can be measured with wearable activity monitors (AM). AM's have been validated and used in joint arthroplasty patients to count postures, walking or transfers. However, for demanding patients such as after sports injury, running is an important activity to quantify. A new AM algorithm to distinguish walking from running is trialed in this validation study.
Methods
Test subjects (n=9) performed walking and running bouts of 30s duration on a treadmill at fixed speeds (walking: 3, 4, 5, 7km/h, running: 5, 7, 9, 12, 15km/h) and individually preferred speeds (slow, normal, fast, maximum, walk/run transition). Flat and inclined surfaces (8%, 16%), different footwear (soft, hard, barefoot) and running styles (hind/fore-foot) were tested. An AM (3D accelerometer) was worn on the lateral thigh. Previously validated algorithms to classify all gait as walking were adapted to differentiate running from walking, the main criterium being vertical acceleration peaks exceeding 2g within each subsequent 2s-interval. Independently annotated video observation served as reference.
Background
Complete and reliable outcome assessment is important for clinical quality control and research evidence. Online questionnaires offer the opportunity to perform follow-up at distance and desired frequency saving efforts and cost to patients and hospitals increasingly not reimbursed for this service. Patients in this unique study have been invited by mail (not at visit or by phone) and were asked to complete both methods (online, paper) instead of only one option. For the first time, response, completion and reliability of the HOOS, KOOS-PS and New-KSS, popular patient-reported outcomes (PROM's) in TJA were measured.
Methods
Patients (n=107) were invited pre-operative by mail to register at atriumproms.nl (Interactive Studios, Netherlands) and complete PROM's online, followed by a second invitation three days later to complete the same on paper. THA patients (n=48) completed EQ-5D-3L, VAS pain and HOOS. TKA (n=59) questionnaires consisted of KOOS-PS, VAS pain and New-KSS. Reliability was assessed using intraclass correlation coefficient (ICC). ICC was considered excellent >0.75 according to literature.
Background
The goal of total hip arthroplasty (THA) is to reduce pain, restore function but also activity levels for general health benefits or social participation. Thus evaluating THA patient activity can be important for diagnosis, indication, outcome assessment or biofeedback.
Methods
Physical activity (PA) of n=100 primary THA patients (age at surgery 63 ±8yrs; 49M/51F; 170 ±8cm, 79.8 ±14.0kg) was measured at 8 ±3yrs follow-up. A small 3D accelerometer was worn for 4 successive days during waking hours at the non-affected lateral upper leg. Data was analysed using validated algorithms (Matlab) producing quantitative (e.g. #steps, #transfers, #walking bouts) and qualitative (e.g. cadence, temporal distribution of events) activity parameters. An age matched healthy control group (n=40, 69 ±8yrs, 22M/18F) served as reference.
Background
In total knee arthroplasty (TKA), patient reported outcome on pain, function or satisfaction fails to differentiate treatment options. Activity, a consequence of pain-free, well functioning TKA and a satisfied patient, may be a discriminative surrogate metric, especially when objectively measured.
Methods
Habitual activity was measured in TKA patients (n=32, F/M=20/12, age: 72 ±8yrs) at long-term follow-up (9 ±1yrs) and compared to healthy, age matched controls (n=32, F/M=20/12, age: 71 ±9yrs) using a popular questionnaire (SQUASH) and accelerometry. A small 3D accelerometer (X16-mini, GCD Dataconcepts) was worn for 4 successive days during waking hours at the non-affected lateral upper leg. Data was analysed using validated algorithms (Matlab) counting and timing walking bouts, steps, sitting periods and transfers. Stair climbing events or similar activities such as walking steep slopes were classified using the higher mean hip flexion angle as a feature.
Background
Sclerostin is a secreted glycoprotein that inhibits the intracellular Wnt signaling pathway, which when inactivated bone formation is stimulated. This stimulation has been proven in fracture studies, showing larger and stronger calluses with accelerated fracture healing, both in sclerostin knockout and sclerostin antibody injection models. The effects of these two mechanisms have not been compared to assess the accurate effect of the Scl-Ab injections. Therefore we designed a study to compare the effect of sclerostin depletion (sclerostin knockout) and inhibition (Scl-Ab injection).
Methods
10-week-old male SOST knockout (KO) (N=20) and Wild-type (WT) (N=40) mice underwent insertion of a tibial intramedullary pin after which a mid-shaft tibial osteotomy was performed. The mice were divided into three groups: SOST KO (N=20), WT with Scl-Ab injection “intravenous dose of 100mg/kg weekly” (N=20) and WT with saline injection (N=20). Each group was managed and sacrificed according to the specified protocol.
Background
Open reduction and internal fixation using plate osteosynthesis for midshaft clavicle fractures is often associated with hardware prominance. Although clinical studies have suggested a role for the use of thinner 2.7mm plates as a means of increasing cosmetic acceptability this still remains an area of controversy. We investigated the effect of plate size (2.7mm vs. 3.5mm), plate treatment (annealed vs. cold worked) and number of screws on the stiffness and yield point.
Methods
Twenty-four synthetic clavicles were randomly divided into four treatment groups - Synthes (Synthes, Paoli, PA) 2.7mm cold-worked calcaneal reconstruction plate with six or eight bicortical screws; 3.5mm LCP reconstruction plate (RP) and 3.5mm LCP pre-contoured superior-anterior clavicle plate (PCSA). After measuring the baseline stiffness of the intact specimens, all clavicles were plated, a wedge-shaped inferior defect was created and testing performed using a cantilever-bending model. Statistical analysis was performed using one-way ANOVA with Tukey's multiple comparison test with significance set at a P value <0.05.
Background
Some models of knee osteoarthritis (OA) suggest that the properties of knee tissues are adapted in healthy joints, and that OA development is due to a breakdown in the equilibrium among tissue properties. Cartilage thickness and bone density are particularly important properties in this regard because both are related to the mechanical environment. This study tested the hypothesis that locations of thickest cartilage are associated with locations where bone density is the highest in non-OA tibias.
Method
CT-arthrography was performed on six non-OA subjects (2 males; 58± 15 years old). Images were segmented to build 3D models of the bone and cartilage structures. Maps of cartilage thickness were calculated for the medial and lateral subchondral bone areas by measuring the distance between bone and cartilage structures. Bone density maps were calculated based on the intensity of the CT-arthrography signal in the first 3mm of bone. The location of thickest cartilage and most dense bone were measured in the medial and lateral compartments. These locations were then normalised, and paired t-tests and linear regressions were performed to compare the thickness and density locations.
Background
Structural and functional outcome of bone graft with first or second generation autologous chondrocyte implantation (ACI) in osteochondral defects has not been reported.
Methods
Seventeen patients (mean age of 27±7 years, range 17–40), twelve with osteochondritis dissecans (OD) (ICRS Grade 3 and 4) and five with isolated osteochondral defect (OCD) (ICRS Grade 4) were treated with a combined implantation of a unicortical autologous bone graft with ACI (the Osplug technique). Functional outcome was assessed with Lysholm scores. The repair site was evaluated with the Oswestry Arthroscopy Score (OAS), MOCART score and ICRS II histology score. Formation of subchondral lamina and lateral integration of the bone grafts were evaluated from MRI scans.
Background
Microfracture (MF) and Autologous Chondrocyte Implantation (ACI) are used to repair symptomatic condylar cartilage defects (grade II-IV Outerbridge). Superiority of ACI to MF is still debated. The aim of the study was to conduct a systematic literature review, compare superiority of ACI versus MF in a meta-analysis and investigate the correlation between patient age and outcome of both treatments.
Methods
Extended literature search was conducted (papers from January 2001 to present), looking at patient characteristics, pre- and post-operative scores and cartilage repair assessment evaluation. Methodological quality was verified through modified Coleman score and assessment bias. A fixed-effect meta-analysis was conducted, comparing post-operative standardised mean differences between ACI and MF. Pearson correlation coefficient between post-operative score and age was calculated against ACI and MF.
Background
Inflammation and chemokines play a pivotal role in aseptic loosening (AL) and prosthetic joint infection (PJI) of total joint arthroplasty (TJA). Recently, the Duffy antigen receptor for chemokines (DARC) on erythrocytes was identified as a potent chemokine receptor able to bind and carry without deactivating a wide range of CXC and CC chemokines from circulation to tissues. The role of DARC and its functional polymorphism (SNP) influencing the number of the DARC molecules on the erythrocytes in AL/PJI has not been studied yet.
Methods
We genotyped functional polymorphism in the DARC gene (rs12075) using MassArray technology (Agena Bioscience) in 354 patients with TJA (hip and knee arthroplasties). Patients were further subdivided into those with a complication (AL, n = 110; PJI, n = 126) and a control group without complications for at least 10 years (n = 118). Statistics was performed by Plink 1.07 and relative entropy.
Background
Adverse reactions to metal debris are implicated in the failure of metal-on-metal hip arthroplasty. The peri-implant tissues are often infiltrated by leukocytes which may cause observed immunological effects, including soft tissue necrosis and osteolysis. Cobalt ions from orthopaedic implants aberrantly activate the innate immune receptor human toll-like receptor-4 (TLR4), leading to inflammatory cytokine release including interleukin-8 (IL-8). IL-8 has been shown to increase expression of intercellular adhesion molecule-1 (ICAM-1) and vascular cell adhesion molecule-1 (VCAM-1). These factors are essential for leukocyte adhesion to endothelium, which is required for leukocyte migration into tissues. This study investigates cobalt's effect on gene and protein changes in IL-8, ICAM-1 and VCAM-1 to determine their potential role in immune cell infiltration of peri-implant tissues.
Methods
TLR4-expressing human dermal microvascular endothelial cells (HMEC-1) were treated with a range of clinically relevant cobalt ion concentrations. IL-8 protein secretion was measured by enzyme-linked immunosorbent assay (ELISA). Gene expression changes were quantified by TaqMan-based real time polymerase chain reaction.
Background
Reduced bone mineral density is recognised as a risk factor for hip fractures and fragility fractures in general. Vitamin D is important in maintaining healthy bone mineral levels and can therefore affect risk of hip fracture. We investigated the correlation between vitamin D levels and bone mineral density, as well as fracture type, in neck of femur fractures and also assessed the relationship of vitamin D and social deprivation.
Method
We included all patients admitted to our department, with a neck of femur fracture over one year (October 2013 to October 2014). We analysed vitamin D levels for all patients during admission and compared these to bone mineral density scores, based on DEXA scan results; hip fracture type & comminution, based on admission radiographs; and levels of social deprivation, based on the patient's address.
Background
A large proportion of the expense incurred due to hip fractures arises due to secondary factors such as duration of hospital stay and additional theatre time due to surgical complications. Studies have shown that the use of intramedullary (IM) nail fixation presents a statistically higher risk of re-fracture than plating, which has been attributed to the stress riser at the end of the nail. It is not clear, however, if this situation also applies to unstable fractures, for which plating has a higher fixation failure rate. Moreover, biomechanical studies to date have not considered newer designs of IM nails which have been specifically designed to better distribute weight-bearing loads. This aim of this experimental study was to evaluate the re-fracture risk produced by a newer type of nailing system compared to an equivalent plate.
Methods
Experimental testing was conducted using fourth generation Sawbones composite femurs and X-Bolt IM hip nail (n=4) and fracture plate (n=4) implants. An unstable pertrochanteric fracture pattern was used (AO classification: 31-A1 / 31-A2). Loading was applied along the peak loading vector experienced during walking, up to a maximum load of 500N. The risk of re-fracture was evaluated from equivalent strains measured using four rosette strain gauges on the surface of the bone at known stress riser locations.
Background
Bio-Active Glass (BAG) is a promising bone graft substitute for large bone defect reconstruction because of its favourable osteoconductive, antibacterial and angiogenic properties. Potentially, it could also mechanically reinforce the defect, thus making it suitable for load-bearing defects. However, the mechanical properties of the reconstructive layer consisting of BAG/bone allograft mixtures are unknown. The goals of this study therefore were, first, to measure the mechanical properties of different BAG/bone graft mixtures and, second, to investigate to what extent such mixtures could reinforce distal tibial defects using micro-FE analysis and high-resolution CT scans.
Materials and Methods
Four different BAG/bone graft mixtures were impacted in a cylindrical holder, mechanically tested in confined compression and scanned with micro-CT. From these images, bone graft material and glass were segmented using two different threshold values. The interface between bone and BAG was modelled separately by dilating the glass phase. Micro-Finite-Element (FE) models of the composites were made using a Young's modulus of 2.5 GPa for bone and 35 GPa for BAG. The Young's modulus for the interface region was determined by fitting experimental and micro-FE results for the same specimens. (82 μm resolution) CT scans of a 9 mm region of the distal tibia of 3 subjects were used. Micro-FE models of this region were made to determine its stiffness in the original state, with a simulated cortical defect and after a mixture of BAG/bone was modelled in the defect.
Background
Implant stability and is an important factor for adequate bone remodelling and both are crucial in the long-term clinical survival of total hip arthroplasty (THA). Assessment of early bone remodelling on X-rays during the first 2 years post-operatively is mandatory when stepwise introduction of a new implant is performed. Regardless of fixation type (cemented or cementless), early acetabular component migration is usually the weakest link in THA, eventually leading to loosening. Over the past years, a shift towards uncemented cup designs has occurred. Besides the established hydroxyapatite (HA) coated uncemented cups which provide ongrowth of bone, new uncemented implant designs stimulating ingrowth of bone have increased in popularity. These cups initiate ingrowth of bone into the implant by their open metallic structure with peripheral pores, to obtain a mechanical interlock with the surrounding bone, thereby stabilising the prosthesis in an early stage after implantation. This retrospective study assessed bone remodelling, osseointegration and occurrence of radiolucency around a new ingrowth philosophy acetabular implant.
Methods
In a retrospectively, single centre cohort study all patients whom underwent primary THA with a Tritanium acetabular component in 2011 were included. Bone remodelling, osseointegration and occurrence of radiolucency were determined by two reviewers from X-ray images that were made at 6 weeks, 3–6-12 and 24 months post-operatively. Bone contact % was calculated based on the original Charnley and DeLee zones. According to Charnley and DeLee the outer surface of an acetabular cup is divided into 3 zones (1-2-3). For our analysis the original 3 zones were further divided into 2 producing 6 zones 1A to 3B. Each of these 6 zones were then further divided into 4 equal sections. We attributed 25 points per section in which complete bone contact without lucency was observed. If lucency was observed no points were attributed to the section. A fully osteointegrated cup in all 24 sections could therefore attain 600 points. The total of each section and zone was subsequently tallied and recalculated to produce the percentage of bone contact on a 1–100% score.
Background
Children suffering from primary bone cancer necessitating resection of growth plates, may suffer progressive leg length discrepancy, which can be attenuated with extendable prostheses. A serious complication is catastrophic implant failure. Over time, bone will remodel, altering the stress pattern in the implant. By using finite element analysis we can model different bone remodeling conditions to ascertain the effect that this will have on stress distribution and magnitude.
A finite element analysis was performed. Simplified computer generated models were designed of a cemented femoral Stanmore growing massive endoprosthesis. Three scenarios were designed, modelled on post-operative radiographs. Scenario 1 had a gap between the end of the femur and the implant collar, scenario 2 had no gap, but with no bone attachment into the collar, and scenario 3 had growth of the bone over the length of the collar with attachment. Physiological loading conditions were applied. The resultant stress in the implant for each scenario was measured, and compared to the strength of the material. Peak stresses were recorded at the stem-collar junction.
The maximum stress recorded in the implant in scenario 1 was 3104.2Mpa, compared to 1054.4Mpa in scenario 2, and 321.2Mpa in scenario 3.
Conclusions
Both accurate reduction and bone growth with attachment to the stem of a massive endoprosthesis will greatly reduce the resultant stress in the implant under loading conditions. The load is redistributed throughout the length of the bone. This may help to prevent catastrophic failure in the implant under loading conditions. Further investigations of patient findings are needed to ensure the model findings are verified.
Modular femoral stems for total hip arthroplasty (THA) were introduced to allow additional options for surgeons in controlling leg lengths, offset, and implant stability. This option is widely used in Region Emilia Romagna, Italy, where the study was conducted, having a modular neck stem nearly 35% of primary THA in 2013. Great majority of modular neck is made of Titanium alloy.
The study was designed as a retrospective descriptive case series of 67 hips in patients who underwent revision of a THA. All had a Titanium modular neck. In 44 cases revision was due to breakage of the neck, in the remaining 23 it was due to different reasons unrelated to modular neck such as bone fracture, breakage of a ceramic component, cup loosening.
Mean follow up was 3.5 yrs. For all patients excised capsule and surrounding tissue were graded for presence of necrosis, inflammatory exudate, lymphocytes, and wear particles using light microscopy of routine paraffin sections stained with hematoxylin and eosin. The retrieved modular neck-body and head-neck junctions were examined for evidence of fretting and corrosion. For some patient dosage of circulating Titanium was obtained. Approval was obtained from institutional review board.
It resulted that a variable amount of wear was observed in the first group of patients, with no evidence of lymphocytic reaction, but with variable notes of necrosis. Broken necks showed different patterns of damage, with different degree of corrosion, beside the fatigue fracture. In the second group wear was less evident or absent and negativity of lymphocyte reaction was substantially confirmed. Circulating Titanium ions were one order of magnitude higher in first group (mean 35 micrograms /litre).
It can be concluded that fracture of Titanium modular necks occurs progressively, wear does not induce lymphocytic reaction and circulating ions increase.
Level of Evidence
III retrospective, comparative study
Acknowledgments
The research was funded by Ministry of Health, grant ‘Early diagnosis of pending failure…’RF 20091472961
Background
Although the tribological characteristics are excellent, cup fixation has been one of the limitations in alumina-on-alumina total hip replacement (THR), so different types of materials and surfaces have been developing. We analysed the clinical and radiological outcome of two different uncemented cups for the same alumina-on-alumina THR.
Methods
679 hips were prospectively followed for at least 5 years. 342 had a hydroxyapatite (HA)-coated relatively smoothed tri-radius cup, implanted between 1999 and 2005 (group 1), and, 337 had a HA-coated macotextured tri-radius implanted between 2006 and 2009 (group 2). Dysplastic hips were more frequently observed in group 2. We compared screw use in both groups as primary fixation, the clinical results, and the radiological appearance of cup loosening.
The increased incidence of type 2 Diabetes Mellitus is associated with an impaired skeletal structure and a higher prevalence of bone fractures. Sclerostin is a negative regulator of bone formation produced by osteocytes and there is recent evidence that its expression in serum is elevated in diabetic patients compared to control subjects. In this study, we test whether hyperglycemia affects serum and bone sclerostin levels in a rat model of type 2 Diabetes as well as sclerostin production by osteoblasts in culture.
We used Zucker diabetic fatty (ZDF) male rats (n=6) that spontaneously develop obesity and frank diabetes around 8–9 weeks of age and Zucker lean rats as controls (n=6) to examine sclerostin expression in serum at 9, 11 and 13 weeks using a specific ELISA. Sclerostin expression in bone tibiae was examined at 12 weeks using immunocytochemistry. Rat osteoblast-like cells UMR-106 were cultured in the presence of increasing concentrations of glucose (5, 11, 22 and 44 mM) during 48 hours and sclerostin mRNA expression and release in the supernatant determined by quantitative PCR and ELISA, respectively.
Our results show that serum sclerostin levels are higher in the diabetic rats compared to lean rats at 9 weeks (+ 140%, p<0.01). Our preliminary results using immunocytochemistry for sclerostin did not show any major difference in sclerostin expression in tibiae of diabetic rats compared to lean ones, although we observed many osteocytic empty lacunae in cortical bone from diabetic rats. Glucose dose-dependent stimulated sclerostin mRNA and protein production in mature UMR106 cells while it had no effect on osteocalcin expression.
Altogether, our data suggest that sclerostin production by mature osteoblasts is increased by hyperglycemia in vitro and enhanced in serum of diabetic rats. Furthers studies are required to determine whether sclerostin could contribute to the deleterious effect of Diabetes on bone.
Background
Bone Morphogenetic Protein (BMP) has been used in clinical practice to stimulate fracture healing and spinal arthrodesis. Difficulty in localising and maintaining BMP at the target site has resulted in the use of large doses of BMP, and has been associated with significant adverse effects. We have previously shown clay hydrogels can bind growth factors for localised efficacy. We hypothesised that localisation of BMP within clay gels would reduce the dose required to mediate bone formation.
Methods
2×10-4mg and 1×10-5 mg BMP were mixed in Laponite and applied to collagen sponge. 3 sponges containing high dose, and 3 containing low dose BMP were implanted subcutaneously in a mouse. This process was repeated in 8 mice, for controls, alginate hydrogel was used in a further 8 mice, and 1 mouse received 6 blank collagen scaffolds. Micro Computed Tomography was used to assess bone formation fortnightly; at 8 weeks the mice were culled and underwent histological analysis.
Background
In the UK, over 160,000 total joint replacements are performed annually. About 1% of patients subsequently develop a deep bacterial infection and, if untreated, this can result in severe pain, disability, and death. Costs to the NHS are substantial. The INFORM (Infection Orthopaedic Management) programme aims to address gaps in knowledge relating to treatment of deep prosthetic joint infection through six work packages. The programme is supported by a patient forum and patient-partners working on oversight groups.
Methods
Literature reviews and meta-analysis of individual patient data from cohort studies of patients treated for prosthetic hip infection. Analysis of the National Joint Registry to observe trends in infection rates, and identify risk markers for infection and effective treatments. Qualitative interviews with patients and health professionals exploring the impact of infection and its treatment. A multicentre randomised controlled trial to compare patient-centred outcomes after one- or two-stage revision for prosthetic hip infection. An economic evaluation to assess cost-effectiveness of treatments. A survey of patients to explore individuals’ preferences for treatments.
Background
The goal of this study was (1) to investigate the relationships between the bony contours of the knee and the popliteus tendon before and after TKA and (2) to analyse the influence of implant sizing. Our hypothesis was that an apparently well-sized prosthesis, will modify the position or the tracking of popliteus tendon.
Methods
4 fresh frozen cadavers were selected. The popliteus tendon was injected with contrast dye and a CT-scan was performed from full extension to full flexion with increments of 20°. Afterwards a total knee arthroplasty (TKA) was performed. Each cadaver received either a normal-sized, oversized, undersized or mobile bearing prosthesis. After TKA the limb was scanned again using the same protocol as before. 3D-reconstructions were created using Materialise Mimics software. These 3D-models were then imported into custom made Matlab software to measure and compare the deviation of the popliteus tendon before and after TKA.
Background
The Nottingham Hip Fracture Score (NHFS) is a risk stratifying score that estimates the 30-day and 12-month mortality rates of hip fracture patients. To date, it has only been validated in few centres in the UK. Our study aims to see how our mortality rates compare with those predicted by the NHFS.
Methods
The Nottingham Hip Fracture Database was reviewed for patients presenting to our unit from August 2012 - March 2013 with a neck of femur fracture. Patient information was obtained from the database and our online electronic patient records for NHFS calculation. Patients with incomplete data were excluded.
Background
Metastatic bone patients who require surgery needs to be evaluated in order to maximise quality of life and avoiding functional impairment, minimising the risks connected to the surgical procedures. The best surgical procedure needs to be tailored on survival estimation. There are no current available tool or method to evaluate survival estimation with accuracy in patients with bone metastasis. We recently developed a clinical decision support tool, capable of estimating the likelihood of survival at 3 and 12 months following surgery for patients with operable skeletal metastases. After making it publicly available on
Methods
We collected data from patients treated at 13 Italian orthopaedic oncology referral centers between 2008 and 2012, then applied to PATHFx, which generated a probability of survival at three and 12-months for each patient. We assessed accuracy using the area under the receiver-operating characteristic curve (AUC), clinical utility using Decision Curve Analysis DCA), and compared the Italian patient data to the training set (United States) and first external validation set (Scandinavia).
Background
Chronic pain after joint replacement is common, affecting approximately 10% of patients after total hip replacement (THR) and 20% of patients after total knee replacement (TKR). Heightened generalised sensitivity to nociceptive input could be a risk factor for the development of this pain. The primary aim of this study was to investigate whether preoperative widespread pain sensitivity was associated with chronic pain after joint replacement.
Methods
Data were analysed from 254 patients receiving THR and 239 patients receiving
TKR. Pain was assessed preoperatively and at 12 months after surgery using the Western Ontario and McMaster Universities Osteoarthritis Pain Scale. Preoperative widespread pain sensitivity was assessed through measurement of pressure pain thresholds (PPTs) at the forearm using an algometer. Statistical analysis was conducted using linear regression and linear mixed models, and adjustments were made for confounding variables.
Introduction
We used patient reported outcome measures (PROMS) to evaluate qualitative and societal outcomes of trauma.
Methods
We collected PROMs data between Sept 2013 and March 2015 for 92 patients with injury severity score (ISS) greater than 9. We enquired regarding return to work, income and socioeconomic status, dignity and satisfaction and the EQ-5D questionnaire.
Objective
Total Hip Arthroplasty (THA) and Total Knee Arthroplasty (TKA) bring relief of pain and functional disability to patients with end stage osteoarthritis, however the literature on their impact on patients’ level of physical activity (PA) is scarce.
Methods
Cross-sectional study, performed in 2012, in 515 patients who underwent THA/TKA surgery in 2010–2011 and a random sample of persons aged >40 years from the Dutch general population participating in a national survey in the same period. PA in minutes per week (min/week) and adherence to the Dutch recommendation for health enhancing PA was measured by means of the Short QUestionnaire to ASsess Health enhancing PA (SQUASH) Additional assessments included socio-demographic characteristics, the presence of comorbidities, BMI and Short Form-12. Multivariable linear (total min/week) and logistic regression analyses (meeting PA recommendation), adjusting for confounders, were performed for THA and TKA separately.
Background
Understanding vertebral fracture is important in order to reduce fracture risk. Previous studies have used FE to investigate mechanical behaviour, typically using a linear material response. This study aimed to establish a novel model that could represent the plastic behaviour leading to fracture.
Method
Porcine vertebrae were mCT scanned and they were loaded to failure in a material test machine (Instron 5965). The specimens were then rescanned. From the first scan, specimen specific FE models were created (ScanIP, Simpleware, UK). Mesh convergence was studied and tetrahedral elements with an approximate element size of 0.7 were used for computational simulations. The relationship between greyscale values (GS) and Young's modulus (E) was optimised to match the experimental load displacement data using Ansys. Further, a plastic material response was modelled.
Daytime spinal loading is twice as long as night time rest, but diurnal disc height changes due to fluid flow are balanced. A direction-dependent permeability of the endplates, favouring inflow over outflow, has been proposed to explain this; however, fluid also flows through the annulus fibrosus. This study investigates the poro-elastic behaviour of entire intervertebral discs in the context of diurnal fluid flow.
Caprine discs were preloaded in saline for 24 hours under different levels of static load. Under sustained load, we modulated the disc's swelling pressure by replacing saline for demi-water and back again to saline, both for 24h intervals. We measured the disc height creep and used stretched exponential models to determine the respective time constants.
Reduction of culture medium osmolality induced an increase in disc height, and the subsequent restoration induced a decrease in disc height. Creep varied with the mechanical load applied. No direction-dependent resistance to fluid flow was observed. In addition, time constants for mechanical preloading were much shorter than for osmotic loading, suggesting that outflow is faster than inflow. However, a time constant does not describe the actual rate of fluid flow: close to equilibrium fluid flow is slower than far from equilibrium. As time constants for mechanical loading are shorter and daytime loading twice as long, the system is closer to the loading equilibrium than to the unloading equilibrium. Therefore, paradoxically, fluid inflow is faster during the night than fluid outflow during the day.
The aim of our study is to investigate the relation between the intensity of pain in the thoracic and lumbar spine and morphometric parameters of vertebrae in postmenopausal women.
Materials and methods
We have examined 250 postmenopausal women aged 50–79 years divided into two groups: 171 women without vertebral deformations and 79 women with confirmed vertebral fractures. The duration of pain syndrome after fracture was over 6 months. The presence and intensity of pain syndrome in the thoracic and lumbar spine were assessed using a visual analog scale (VAS). Morphometric analysis of the vertebral parameters was carried out using the VFA software of the dual-energy X-ray densitometer «Prodigy» (GE Medical systems, Lunar, model 8743, 2005).
Results
The intensity of pain syndrome in the lumbar spine significantly correlates with L1 vertebral indices: A/P (r=−0.37, p=0.01) and M/P (r=−0.29, p=0.03) in women with normal BMD. The intensity of pain in the thoracic region correlates with Th10 vertebral indices: A/P (r=−0.45, p=0.0004) and M/P (r=−0.35, p=0.01) in women with osteopenia. We have not determined any significant relationship between the level of back pain and vertebral body size index in women with osteoporosis and without vertebral fractures. In 11% patients with confirmed wedge and compression vertebral fractures chronic pain syndrome is absent, and the presence of other fractures does not increase the frequency of back pain syndrome (14%). The presence of vertebral fractures significantly increases the risk of pain in the thoracic spine (RR=1.32; 95% CI: 1.09–1.60, p= 0.004). In patients with vertebral fractures the intensity of pain in the thoracic spine significantly correlates with indices of Th11-Th12vertebrae, and relates to the number and localisation of vertebral fractures. The level of pain in the lumbar region does not depend on the location and number of damaged vertebrae.
Background
Oblique implantable total disc replacements (TDR) have been developed in an attempt to partially resect the anterior longitudinal ligament (ALL), together with additional partial resection of lateral annulus fibres. To date, the literature has not addressed the impact of the TDR oblique implantation on the lumbar spine sagittal alignment. The hypothesis of this study was that TDR at the L4-L5 level does not change the sagittal alignment and the range of motion of the lumbar spine when the implant is placed in accurate position.
Methods
Prospective single-center radiological investigation of L4/5 TDR inserted through an oblique approach for the treatment of disc disease. A series of 52 patients with a minimum of 2-year FU after oblique TDR at L4/L5 level was analysed for radiological changes in sagittal alignment and range of motion of the lumbar spine. The total sagittal lumbar lordosis (TSLL), the segmental sagittal lumbar lordosis (SSLL) of the operated level, and the range of motion of the TDR implant were determined in pre- and postoperative functional X-rays. The accuracy of the implant position was also evaluated.
Background
While the biomechanical properties of trans-pedicular screws have proven to be superior in the lumbar spine, little is known concerning pullout strength of trans-pedicle screws in comparison to different distal terminal constructs like sublaminar hooks alone, trans pedicular screws with sublaminar hooks and clow hooks alone in the thoracolumbar spine surgery. In vitro biomechanical pullout testing was performed to evaluate the axial pullout strength of four different distal terminal constructs in thoracolumbar spine surgery.
Methods
32 fresh-frozen lamb spines were used. The lamb spines were divided into four groups, each group is composed of eight lamb spine cadavers with a different distal fixation pattern was used to terminate the construct at L1. (Group 1) trans-pedicular screws alone, (Group 2) sublaminar hooks alone, (Group 3) trans-pedicular screws augmented with a sublaminar hooks via a domino connector and (Group 4) clow hooks alone.
Background
Using flexible tethering techniques, porcine models of scoliosis have been previously described. These scoliotic curves showed vertebral wedging but very limited axial rotation. In some of these techniques, a persistent scoliotic deformity was found after tether release. The possibility to create severe progressive true scoliosis in a big animal model would be very useful for research purposes, including corrective therapies.
Methods
The experimental ethics committee of the main institution provide the approval to conduct the study. Experimental study using a growing porcine model. Unilateral spinal bent rigid tether anchored to two ipsilateral pedicle screws was used to induce scoliosis on eight pigs. Five spinal segments were left between the instrumented pedicles. The spinal tether was removed after 8 weeks. Ten weeks later the animals were sacrificed. Conventional radiographs and 3D CT-scans of the specimens were taken to evaluate changes in the coronal and sagittal alignment of the thoracic spine. Fine-cut CT-scans were used to evaluate vertebral and disc wedging and axial rotation.
Introduction
The highest incidence of recurrent shoulder instability is in young patients, surgical repair can reduce recurrent instability and improve shoulder function. This has led to an increasing rate of stabilisation and use of MRI to identify associated injuries in first time dislocations. MRA has the benefit of distending the joint and is becoming increasingly used. The aim of this study is to establish the sensitivity and specificity of MRA in the investigation of patients with traumatic anterior shoulder dislocations.
Methods
A retrospective analysis of patients undergoing both magnetic resonance arthrography and arthroscopy after a traumatic anterior shoulder dislocation between January 2011 and 2014. Images were interpreted by eight musculoskeletal radiologists and arthroscopic findings were obtained from surgical notes and used as a reference. The sensitivity, specificity and positive predictive value for the different injuries were calculated.
Background
There is a paucity of long term data concerning the pre and postoperative patient reported function of total knee replacement. The aim of this study was to determine the mortality, implant survivorship, patient reported function and satisfaction in a cohort of 114 patients, from a single centre, who received a Kinemax total knee replacement more than 15 years ago.
Methods
Patients completed a questionnaire incorporating validated disease- and joint-specific scores, patient satisfaction and overall health preoperatively, at 3 months, 1 year, 2 years and a minimum of 15 years following surgery. NHS National Strategic Tracing Service, hospital and primary care records were used to establish mortality and for implant survivorship in deceased patients.
Background
Smoking has been associated with poor tissue oxygenation and vascularisation, predisposing smokers to a higher risk for postsurgical infections. The aim of this study was to estimate and compare the incidence of prosthetic joint infection (PJI) following primary total joint arthroplasty (TJA) according to smoking status.
Methods
A prospective hospital-registry based cohort was used including all primary total knee and hip arthroplasties performed between 03/1996 and 12/2013 and following them until 06/2014. Smoking status at time of surgery was classified in never, former and current smoker. Incidence rates and incidence rate ratios (IRR) for PJI according to smoking status were assessed within the first year and over the whole study period. Adjusted IRRs were obtained using cox regression model. Adjustment was performed for the following baseline characteristics: age, sex, BMI, ASA score, diabetes, arthroplasty site (knee or hip) and surgery duration.
Background
In the United Kingdom (UK), the fastest growing population demographic is the over 85 years of age, but despite this, outcomes achieved in the octogenarian population with a Unicompartmental Knee Replacement (UKR) are underrepresented in the literature. The Elective Orthopaedic Centre, Epsom, has an established patient reported outcome measures (PROMs) programme into which all patients are routinely enrolled. We aim to investigate the outcome of medial UKR using the oxford phase 3 implant in octogenarians.
Methods
We retrospectively reviewed our database for patients aged 60–89 years, who underwent a medial unicompartmental Knee Replacement (UKR) using the oxford phase 3 implant, between June 2007-December 2012 (N=395). The patients were stratified into 3 groups based on age, 60–69 (N=188), 70–79(N=149), and 80–89(N=58). Oxford Knee Scores (OKS), Euro-quol (EQ-5D) scores, revision rates, and mortality were compared.
Background
The pattern of appearance of secondary ossification centers in the elbow has been based on historical studies and is popularly referred to with the mnemonic CRITOL. However the six secondary ossification centers can be variable in their presentation and pose a challenge in assessment of children with elbow injuries. Furthermore limited studies available in the current literature have reported an aberration to the sequence of appearance especially with the ossification centers of trochlea and olecranon.
Aims
The aim of the study was to evaluate the relative sequence of appearance of secondary ossification centers for the trochlea and olecranon.
Background
Pain control following knee replacement (TKR) surgery is often poor. Moderate to severe pain is often reported in the first 48 hours following surgery requiring opiate analgesia. The Local Infiltration Anaesthetic (LIA) technique has been described as a method to reduce post operative pain. In this study we report on our experience using LIA in addition to the PainKwell system (Peak Medical) of continuous infusion intra-articularly, of 0.25% bupivacaine at 4–5 mls/hour for 48 hours post surgery. The PainKwell catheter is placed in the knee joint during surgery.
Methods
Between the June 2012 and Sep 2012, 62 patients undergoing primary TKR were prospectively followed up. All patients studied had spinal anaesthesia (SA) with diamorphine. Group 1. GA. No LIA and no PainKwell. 20 patients. Group 2. SA plus LIA plus PainKwell for 48 hours post operatively with catheter placed anteriorly under the patella. 21 patients. Group 3. SA plus LIA plus PainKwell for 48 hours post operatively with catheter placed posteriorly in the knee joint. 21 patients.
Background
There are multiple documented advantages of undertaking total knee arthroplasty (TKA) without tourniquet, however, increased rates of blood loss and transfusion are often cited as contraindications to this approach. The aim of this study was to examine the effect of intra-operative TA administration on blood loss and transfusion rates in TKA without pneumatic tourniquet, using Rivaroxaban as thrombo-embolic prophylaxis.
Method
120 patients split into two continuous data sets, (A+B), underwent TKA without application of above knee tourniquet, receiving a post operative dose of oral Rivaroxaban within 8 hours. Group B patients received an intra-operative dose of 1 gram of Tranexamic Acid intravenously before the first cut, whilst those in group A did not. Haemoglobin and haematocrit levels were recorded peri-operatively. A revised Gross formula was used to calculate blood loss. Four patients were excluded from the study for incomplete data.
Introduction
Perioperative antibiotic prophylaxis use in modern orthopaedic procedures is well established. Studies have shown significant reduction in risk of post-operative infections. However, as effectiveness of these antibiotics is dependent on achieving high serum and tissue concentrations that exceed the minimum inhibitory concentrations of infective organisms for operation duration, the timing of prophylaxis is crucial. Although, optimal timing for administering prophylaxis varies in the literature, 30 to 60 minutes prior to skin incision or inflation of tourniquet is considered best standards.
Objectives
To audit our practice of timing of administration of perioperative prophylactic antibiotics in trauma and orthopaedic procedures.
Introduction
Osteonecrosis of the knee encompasses three conditions; spontaneous osteonecrosis of the knee, secondary osteonecrosis (ON) and post-arthroscopic ON. Early stage lesions can be managed by non-operative measures that include protected weight-bearing and analgesia. The aim of this study was to report the experience of the authors in managing early stages of knee ON by analysing the functional outcome and need for surgical intervention.
Methods
All patients treated for osteonecrosis of the knee between 1st August 2001 and 1st April 2014 were prospectively collected. Treatment consisted of touch-down weight bearing for four to six weeks. The cases were retrospectively reviewed. MR imaging was evaluated for the stage of disease according to Koshino's Classification system, the condyles involved and the time taken for resolution. Tegner Activity Scale, VAS pain, Lysholm, WOMAC and IKDC scores were recorded at presentation and final follow up.
Background
To investigate whether the interaction between pre-operative widespread hyperalgesia and radiographic osteoarthritis (OA) was associated with pain severity before and after total hip replacement (THR) and total knee replacement (TKR).
Methods
Data were analysed from 232 patients receiving THR and 241 receiving TKR. Pain was assessed pre-operatively and at 12 months post-operatively using the WOMAC Pain Scale. Widespread hyperalgesia was assessed through forearm pressure pain thresholds (PPTs) measured using an algometer. The severity of radiographic OA was evaluated using the Kellgren and Lawrence scheme. Statistical analysis was conducted using linear regression and multilevel models, and adjusted for confounding variables.
Background
Osteoarthritis (OA) pain treatment has limitations in terms of serious adverse effects and low efficacy. We aimed to evaluate efficacy and safety of naproxen sodium/codeine phosphate combination in these patients.
Methods
In this prospective, randomised, double blind, placebo controlled clinical trial, 135 patients with osteoarthritis, who were 40–65 years; applied to our institution's orthopaedics outpatient clinic; had grade 1, 2, or 3 primary osteoarthritis diagnosed in last 1 year; and had Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score≥40, and Visual Analogue Scale score≥40, were enrolled. Subjects were randomised (1:1) to placebo (n= 67) or combination (n= 68) arms, in which 550 mg naproxen sodium/30mg codeine phosphate was given orally twice a day for 7 days. Rescue medicine was 500 mg paracetamol (max= 6 tablets/day). Demographic characteristics, medical history, adverse events, VAS and WOMAC scores were collected in study visits performed within 10 days. The study was approved by local institutional ethics committee and written informed consents were obtained from all participants.
Background
Predicting length of stay (LOS) is key to providing a cost effective and efficient arthroplasty service in an era of increasing financial constraint. Previous studies predicting LOS have not considered enhanced recovery protocols in elective hip and knee arthroplasty. Our study aims to identify patient variables in the pre and peri-operative period to predict increased LOS on patients enrolled into the standardised Chichester and Worthing Enhanced Recovery Programme (CWERP).
Methods
All patients undergoing elective hip and knee arthroplasty were enrolled into CWERP using standardised anaesthetic, surgical and analgesic protocols. A data analyst prospectively collated data over 6months from anaesthetic charts and daily ward review from 663 patients between Dec 2012 and June 2013.
An independent statistician undertook statistical analysis (program R, version 3.1.1). 80% of the 6months consecutive data (530 patients) were analysed, and predictive variables identified. These variables were tested against the remaining 20% of data (133 patients) predicting a LOS greater or less than our median of 4 days.
Objectives
To evaluate the in vitro effects of hyaluronic acid (HA) on adipose-derived stem cells (ASC) in order to consider the possibility of their combined used in the treatment of knee arthrosis.
Material and methods
The ASC cells were grown both in the presence and absence of AH, and several studies were carried out: proliferation (WST8) and cell viability studies (Alamar Blue and Trypan Blue), possible chondrogenic differentiation (collagen type 2 expression) by RT-PCR, AH receptor expression (CD44) by flow cytometry and RT-QPCR, and expression of inflammatory and anti-inflammatory factors (IL-6, TGFß, IL-10) by RT-QPCR.
Background
There are currently no effective treatments for skeletal muscle fibrosis. Myofibroblasts are the major cellular effectors of fibrosis but their origin in muscle is unknown. We report that PDGFRβ (platelet derived growth factor receptor beta) Cre inactivates genes in murine PDGFRβ+ cells and myofibroblasts in muscle with high efficiency. We used this system to delete the integrin αv subunit because of the suggested role of multiple αv integrins as central mediators of fibrosis in multiple organs.
Methods
Muscle fibrosis was induced by intramuscular cardiotoxin (CTX) injection. The contribution of PDGFRβ+ cells to fibrosis was assessed in double-flourescent reporter (mTmG) mice under PDGFRβ-Cre control. Itgavflox/flox;PDGFRβ-Cre mice were used to investigate whether loss of αv integrins on PDGFRβ+ cells influences fibrosis development. A small-molecule inhibitor of αv integrins (CWHM12) was used to determine whether pharmacological blockade of αv integrins could attenuate fibrosis.
Introduction
The management of adolescent hallux valgus (AHV) remains controversial, with reservations about both conservative and surgical treatments. Non-operative management has a limited role in preventing progression. Surgical correction of AHV has, amongst other concerns, been associated with a high prevalence of recurrence of deformity after surgery. We conducted a systematic review to assess clinical and radiological outcomes following surgery for AHV.
Methods & Materials
A comprehensive literature search was performed in the Cochrane Library, CINAHL, EMBASE, Google Scholar, and Pubmed. The study was performed in accordance with the recommendations of the PRISMA guidelines. Demographic data, radiographic parameters, and results of validated clinical scoring system were analysed.
Introduction
Orthopaedic trauma surgery is characterised by repetitive, forceful tasks that are physically demanding, thus theoretically increasing the risk of musculoskeletal injuries in these surgeons. The aim of this study is to assess prevalence, characteristics and impact of musculoskeletal disorders among orthopaedic trauma surgeons.
Methods
A modified version of the physical discomfort survey was sent to surgeon members of the Orthopaedics Trauma Association (OTA) via e-mail. For data analysis, one-way ANOVA and Fisher Exact test were performed to compare the variables where appropriate. P values<0.05 were considered statistically significant.
Background
The discussion over the duration, type of therapy and regimen to be used in osteoarticular tuberculosis is losing importance in all orthopaedic gathering. Still little consensus is there over the universality of a treatment regime for osteoarticular tuberculosis.
Material and Method
340 new cases of osteoarticular tuberculosis were included in the study that were medically treated in the department of orthopaedics in a tertiary care center between 2001 and 2011. Out of which 202 cases were of spinal tuberculosis and 138 cases of extraspinal tuberculosis. 88 cases of spinal tuberculosis were treated by conventional method and 114 cases by short course chemotherapy. 60 cases of extraarticular tuberculosis were treated by conventional chemotherapy and 78 cases by short course and intermittent therapy.
Background
New marker free motion analysis systems are being used extensively in the area of sports medicine and physiotherapy. The accuracy and validity of use in an orthopaedic setting have not been fully assessed for these newer marker free motion analysis systems. The aim of this study is to compare leg length and varus/valgus knee measurements performed by leg measurement x-ray, and performed using the new marker free motion analysis system (Organic motion biostage).
Methods
Patients attending the orthopaedic department for total knee replacements were recruited. They underwent radiological leg measurement x-ray, clinical leg measurement, and finally assessment using the organic motion biostage system. These were analysed using the motion monitor software, microsoft excel and minitab 16.
Background
Metastatic bone patients who require surgery needs to be evaluated in order to maximise quality of life and avoiding functional impairment, minimising the risks connected to the surgical procedures. The best surgical procedure needs to be tailored on survival estimation. There are no current available tool or method to evaluate survival estimation with accuracy in patients with bone metastasis. We recently developed a clinical decision support tool, capable of estimating the likelihood of survival at 3 and 12 months following surgery for patients with operable skeletal metastases. After making it publicly available on
Methods
We collected data from patients treated at 13 Italian orthopaedic oncology referral centers between 2008 and 2012, then applied to PATHFx, which generated a probability of survival at three and 12-months for each patient. We assessed accuracy using the area under the receiver-operating characteristic curve (AUC), clinical utility using Decision Curve Analysis DCA), and compared the Italian patient data to the training set (United States) and first external validation set (Scandinavia).