Advertisement for orthosearch.org.uk
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Volume 94-B, Issue SUPP_XXXVII September 2012 European Federation of National Associations of Orthopaedics and Traumatology (EFORT) - 12th Congress

Abdul Nazeer Moideen Christopher Wolf Oliver Donaldson Declan O'Doherty

Background

Exeter Trauma Stem (ETS) is a polished tapered collarless monopolar prosthesis used for cemented hemiarthroplasty for fracture neck of femur. Two modular rasps are available on the instrumentation set. The larger rasp, in practice, rarely fits into the femur making trial reduction impossible. Our hypothesis was that the absence of a trial reduction could affect leg length and stability of the prosthesis.

Aim

To evaluate the leg length discrepancy following use of Exeter Trauma Stem for intracapsular fracture neck of femur.


Thies Wuestemann Adam Bastian Javad Parvizi Joseph Nessler Frank Kolisek Jim Nevelos

Introduction

The origins of the uncemented tapered wedge hip stem design currently offered by several orthopaedic device companies can be linked back to the cemented Straight Mueller type stem design first used in 1977. The design, a wedge shape with a taper angle of 6 degrees, maintains a single medial curvature for all sizes and increases laterally in the width to accommodate different size femurs. Although evolutionary improvements have been made over the years the basic body geometry of the stem has stayed mainly unchanged with excellent clinical survivorship. Over the past decade, the demographics of hip replacement have changed, with a large increase in younger male patients in the age range of 40 to 60 years. In this study the femoral fit of a novel tapered stem, designed to fit a wide array of patient types, is compared to a standard predicate tapered stem design.

Methods

A bone morphology study was performed on a patient population of 556 patients using three dimensional digital data from CT-scans. To characterize the fit of the stem designs we analyzed the ratio of a distal (60mm below lesser trochanter) and a proximal (10mm above lesser trochanter) cross section. The same measurements were taken with the standard tapered stem design and the novel tapered stem design, with a given constant implantation height of 20mm above the lesser trochanter. The fit of the stems was classified as Type 1, where there was both proximal and distal engagement, Type 2, proximal engagement only, Type 3, distal engagement only. The distal and proximal engagement, Type 1, was specified with a maximum engagement difference of 2mm proximal to distal.


Robert Lee Robert Lee Marcel Dvorak Brian Kwon

Introduction

While there is a desperate need for effective treatments for acute spinal cord injury (SCI), the clinical validation of novel therapeutic interventions is severely hampered by the need to recruit relatively large numbers of patients into clinical trials for sufficient statistical power. While a centre might annually admit 100 acute SCI patients, only a fraction may satisfy the basic inclusion criteria for an acute clinical trial, which typically requires patients of a certain injury severity (eg ASIA A), within a specific time window (eg. 12 hours from injury), and without other major injuries or conditions that would cloud the baseline neurologic assessment. This study was conducted to define that “fraction” of SCI patients that would theoretically satisfy standard inclusion criteria of an acute clinical trial.

Methods

Using a local database, we reviewed patients admitted to our Level 1 trauma center with a complete (ASIA A) or an incomplete (ASIA B, C and D) acute SCI involving bony spinal levels between C0 and sacrum. All patients admitted over the 4 year period from 2005 to 2009 were reviewed. Demographic information and data about the patients' SCI and other injuries were reviewed. We then determined how many of the total number of SCI patients would be eligible for enrolment into a hypothetical acute clinical trial that required a valid baseline assessment of neurologic impairment, and an enrolment window of either 12 hours, 24 hours, or 48 hours.


Peter Poon Peter Poon Justin Chou

Introduction

Reverse shoulder replacement is a surgical option for cuff tear arthropathy. However scapular notching is a concern. Newer designs of glenospheres are available to reduce scapular notching. Eccentric glenosphere with a lowered centre of rotation have been shown to improve range of adduction in vitro. We hypothesize that the eccentric glenosphere improve clinical outcomes and reduce scapular notching.

Method

This is an ongoing randomized controlled double blind prospective clinical trial. Patients 70 years or older at North Shore hospital who have a diagnosis of cuff tear arthropathy and require surgery were consented for this study. Patients were allocated a concentric or eccentric 36 mm glenosphere intraoperatively, using a computer generated randomization contained in a sealed envelope. The surgical technique and post operative rehabilitation were standardized. Patients were followed up by a research nurse and postoperative radiographs were also taken at regular intervals. Clinical assessment include a visual analogue pain score, subjective shoulder rating, American Shoulder and Elbow Society Score, and Oxford shoulder score. Complications were checked for and radiographs were assessed for scapular notching.


Vladimir Kovac

Both posterior and anterior surgery have potential for complete scoliosis correction. Significant difference in judging the procedures still persists.

Aim

To establish objective advantages and risks of the procedures, basing upon long term results.

Method

From 1982–2007, 859 anterior(A) and 388 posterior(P) instrumentations were performed by the same surgeon. Single level thoracotomy used even in double curves. Spinal canal was never opened, rib heads left intact, ribs were fractured at the top of rib hump. Zielke rod was used for correction, and another rod added for aditional correction and stabilisation. Various posterior instrumentations were used.


Piyush Upadhyay James Beazley Mark Dunbar Matthew Costa

Introduction

Locking compression plate (LCP) fixation is an established method of treatment of distal third tibial fractures. No biomechanical data exists in the literature regarding their use. Additionally no data exists on the biomechanical advantage of locking screw fixation over non-locking screw fixation for these fractures. In this study the axial and torsional stiffness, axial load to failure and fatigue performance of a 3.5 mm LCP medial distal tibia Synthes plate was evaluated for the stabilisation of distal third tibial fractures. Additionally the performance of the plate in uni and bicortical locked mode as well as non-locked mode was evaluated.

Methods

A standardized oblique fracture pattern was created in the tibial metaphysis of 3rd generation composite tibias, 40 mm from the distal end of the tibia (AO 43-A2.3). A 10mm fracture gap was used to model a comminuted metaphyseal fracture. A 3.5 mm medial distal tibia LCP was applied with bi or unicortical locking or bicortical non-locking screws to 5 tibias respectively. All the bio-mechanical tests were performed on a Bose 3510 Electroforce material testing machine.

A ramp to load, loading profile was used to determine the static axial and torsional performance of the construct. Fatigue testing simulated a 6 week gradual weight bearing régime with the load increasing every two weeks by 400N until either 250,000 cycles were completed or the construct failed.


Mathias Mosfeldt Ole Pedersen Henrik Jorgensen Henning Ogarrio Benn Duus Jes Lauritzen

Hip fractures are associated with excess mortality, and several studies have pointed out the burden on society health care costs and the need to optimize cost effectiveness in treatment. The goal of our study was to investigate if patients with a higher risk of death after hip fracture could be identified using routine blood tests taken on admission.

All 530 hip fracture patients admitted to the Department of Orthopedics, Bispebjerg University Hospital from October 2008 till December 2009 were included prospectively. Patients under the age of 60 (n = 39) were excluded. Furthermore, because the purpose was to identify blood tests at the time of admission that could predict outcome, we only included patients that had project blood samples taken at the day of admission resulting in 324 hip fracture patients for further analysis. Follow up data on mortality were obtained from the national civil registry the first of February 2010. Predictors for mortality were determined by logistic and cox regression models. P < 0.05 was regarded as statistically significant. Of the 324 hip fracture patients under study, 66 (20%) died within the study period.

The results of stepwise Cox multivariate regression models for survival during the first three months after admission revealed that age, plasma creatinine and albumin predict mortality. The hazard ratios were 1.04 (95% CI: 1.005–1.09, p = 0.02), 1.01 (per unit increase)(95% CI: 1.01–1.02, p<0.0001), and 0.87 (95% CI: 0.80–0.94, p = 0.002) for age, plasma creatinine and albumin respectively. The 90 day mortality was 13% and 42% in patients with normal and elevated plasma creatinine levels respectively.

Hip fracture patients are known to have a high risk of post- operative mortality. Our findings suggest that it might be possible to identify at- risk patients that could possibly benefit from increased attention the first months following surgery using already available blood samples.


Chayanin Angthong Anchalee Sirimontaporn Prasit Lucksanasombool Saranatra Waikakul Aporn Chunjarunee

Introduction

Nowadays, autologous platelet-rich plasma is used commonly in wound treatment. However, platelet gel, which was derived from allogeneic platelet-rich plasma (PRP) [1,2], has never been studied about efficacy in vivo or animal models. We aimed to determine efficacy of allogeneic platelet-gel on wound healing in rats by comparing with untreated, antibiotic-gel (Mupirocin 2%) treated and gel (sodium carboxymethylcellulose(NaCMC))-treated control.

Methods

Fresh frozen plasma was centrifuged at 1200-G for 15 minutes to extract PRP which would be freeze-dried at −70°c, sterilized with gamma ray of Cobalt source 25 kGy and stored at −70°c. Then, processed freeze-dried PRP was mixed with gel base (NaCMC) as in form of allogeneic platelet-gel concentrated 30 mg/1g by sterilization process (table 1). Full-thickness of 6-mm-diameter skin punch biopsies were performed on 18 female Wistar rats which each rat had four wounds at back. Each wound was applied with untreated care, antibiotic-gel, NaCMC-gel and platelet-gel, respectively. Wound healing was studied from day 0–12. Animals were sacrificed with wound tissues removal on day 3, 7, 12 post-biopsy. Digital planimetric measurement device (VISITRAK, Smith and Nephew) was used in evaluation of total wound area on day 0, 3, 7, 12 post-biopsy. Histopathological changes of wound healing were studied, using 4-μm thickness section with haematoxylin-eosin (H&E) and Masson's trichrome-stain, under light microscope.


Oystein Gothesen Birgitte Espehaug Leif Havelin Gunnar Petursson Ove Furnes

Background

Improving positioning and alignment by the use of computer assisted surgery (CAS) might improve longevity and function in total knee replacements. This study evaluates the short term results of computer navigated knee replacements based on data from a national register.

Patients and Methods

Primary total knee replacements without patella resurfacing, reported to the Norwegian Arthroplasty Register during the years 2005–2008, were evaluated. The five most common implants and the three most common navigation systems were selected. Cemented, uncemented and hybrid knees were included. With the risk for revision due to any cause as the primary end-point, 1465 computer navigated knee replacements (CAS) were evaluated against 8214 conventionally operated knee replacements (CON). Kaplan-Meier survival analysis and Cox regression analysis with adjustment for age, sex, prosthesis brand, fixation method, previous knee surgery, preoperative diagnosis and ASA category were used.


Guoxun Gao Khee Sien Lam Eng-Hin Lee

Twenty-three patients with thirty hips of slipped capital femoral epiphysis were treated in our department, KK Women's and Children's Hospital, Singapore between 1997 and 2005. Except one patient lost of follow-up, twenty-four SCFEs with more than 2 years (25 to 73 months, average 38.5 months) follow-up were reviewed. This study is to evaluate the effectiveness and outcome of our protocol: Russell traction followed by gentle manipulative reduction with a single screw fixation & spica cast immobilization (for acute-on-chronic cases with unstable and reducible SCFE). In this series, there were 13 boys & 5 girls, mean age 12 year old ranging from 10 to 14 years. Among them 7 were Chinese, 6 Malays & 5 Indians. There were 12 unilateral cases (8 on the left & 4 right, 67%) & 6 bilateral cases (33%), including 2 patients found contralateral SCFE subsequently 1 year postoperatively. Acute-on-chronic SCFE were 16 & chronic SCFE 8. 16 were Grate I & 8 Grate II. Russell traction was on preoperatively with an average of 6 days. Gentle manipulative reduction under general anesthesia was performed in 20 SCFEs (12 GI & 8 GII) and 17 of them were successful. Fixation with a single screw was used for all cases except one hip with 2 screws. Average follow-up was 38.5 months. Good results achieved. All patient were symptom free with good function. No complications of AVN, chondrolysis, screw loosening and reslipping of the affective hips. Our protocol of management for SCFE has been largely successful in term of manipulative reduction and fixation.


Susanne Van Der Mark Sune Jauffred Henrik Joergensen Troels Riis Henning Ogarrio Benn Duus

For some years, there has been vast international interest in creating models for joint efforts between geriatricians and orthopedic surgeons. We present data from two such models.

For the first time in Denmark, the Department of Orthopedics Bispebjerg University Hospital (BUP) recruited two full-time geriatricians in September 2009. They were assigned an independent unit meant for severely ill orthopaedic patients with high comorbidity and polypharmacy. These two geriatricians had, during the previous two years, consulted another orthopaedic department at Gentofte University Hospital (GUH) in a neighbouring community three times a week. The aim of their intervention was then to optimize treatment for comorbidity, to clarify indication of acute fall-assessment, osteoporosis diagnosis and treatment, presence of delirium and dementia.

Methods

A total of 1344 hip fracture patients (age 70 years) divided into three populations were included in this study. Mortality data were collected from the Danish Civil Registry.

Population 1 (P1), n = 645 was included at GUH from January 1, 2006 to December 31, 2007. During the entire period, the patients had access to a senior consultant in geriatric medicine three times a week. In this population, the majority of patients were assessed for dementia (n = 636), delirium (n = 627) and Barthel Index (Barthel100) at admission (n = 394).

Population 2 (P2), n = 381 included at BUH from September 1, 2009 until July 8, 2010 with orthogeriatric access.

Population 3 (P3), n = 318 were included at BUH from September 28, 2008 until August 31, 2009 with no orthogeriatric access.

Age mean (SD): P1 84.7 (6.8), P2 85.5 (7.3), P3 85.3 (14.3) P = 0.1(ANOVA) Sex ratio: females/males: P1 0.73/0.27, P2 0.80/0.20, P3 0.75/0.25 P = 0.09 Chi square).

Results

In-hospital mortality rate: P1 4.8%, P2 6.3%, P3 9.1% P = 0.03 (Chi square).

Three month mortality: In P1 dementia, delirium and Barthel Index (below 50 versus above 50) were all strong predictors: No dementia: 53/383 (13.8%) versus dementia present 68/253 (26.9%) died, P = 0001 (log-rank test).

No delirium 69/456 (15.1%) versus delirium present 47/171 (27.5%) died F = 0.0004 (log-rank test) Barthel Index 50 38/372 (10.2%) versus Barthel<50 7/22 (31.8%) died P = 0.0004


Michael Skettrup Anne Grete Kjersgaard Camilla Colding Soren Solgaard

Introduction

The postoperative management of patients after total hip replacement traditionally includes restrictions of movements and the use of aids (toiletelevation, sleeping pillow, a.o.) in the first 3 months after operation. Few studies have investigated the benefit of such restrictions. The aim of the present study was to evaluate how patients with total hip replacements (THR) are doing with and without restrictions in the first 3 months after surgery, and if walking ability and patients satisfaction was influenced by the postoperative regime.

Patients and Methods

80 patients undergoing primary uncemented THR were randomized to either the conventional regime with restrictions of movement and obligatory use of aids, or a postoperative regime without restrictions. Surgery was performed through a posterolateral short incision. The femoral component was the uncemented Bimetric prosthesis, non collared with HA coating, and a 36 mm femoral head. The cup was the Trilogy cup with a highly crosslinked polyethylen liner. No postoperative drainage was used and immediate weight bearing was allowed in both groups. We monitored walking speed, TUG score (timed up and go) and VAS pain score. The patients were scored by a trained physiotherapist preoperatively, 2 times each day during admission, and 14 and 90 days after surgery. Radiographic examination was performed after 3 days and after 3 months. At the 3 months evaluation a SF-36 score was registered.


Michalis Panteli John Mcroberts Shayma Habeeb Matthew Porteous

Background

With the recent trend towards enhanced care in joint replacement, it has become increasingly important to identify and address the areas that affect early patient length of stay, while ensuring that practice remains safe. As part of an enhanced care program we conducted two prospective studies of factors delaying discharge following hip replacement in 2006 and 2010.

Materials and Methods

In each limb of the study data was collected prospectively daily, by an independent observer, on 100 consecutive primary cemented total hip replacements. Reasons for delay to the discharge and variation from the patient pathway were identified and addressed.


Michalis Panteli Kazim Kalayci Saagit Kaleel Peter Domos Soren Sjolin Martin Wood

Background

Osteoarthritis of basal joint of the thumb represents one of the commonest degenerative diseases of the hand and wrist region. Depending on the severity of clinical symptoms surgical treatment is often recommended. Resection arthroplasty of the CMC joint with tendon interposition can be regarded as the gold standard. The aim of our study is to compare the Burton Pellegrini technique with a new modified technique of resection arthroplasty with interposition of local capsule tissue.

Materials and Methods

We retrospectively evaluated 2 groups of patients. Two Consultant Surgeons took part in the study, one for each group, with each consultant performing trapeziectomies using only one of the techiniques for all his patients. The first group underwent trapeziectomy and local capsule interposition. It consists of 26 patients with a female/male ratio of 20/6, an average age of 64 years (range 53–88), an average follow up of 3.15 years (range 9–1) and a left/right ratio of 16/10. The second group underwent a standard Burton Pellegrini including flexor tendon interposition. It consists of 13 patients with a female/male ratio of 5/8, an average age of 68 years (range 58–85), an average follow up of 4.46 years (range 9–1) and a left/right ratio of 5/8. The outcomes were compared using the Michigan Hand Outcomes Questionnaire. A 2-tailed independent samples t-test was used for the statistical analysis of our data.


Akintunde George Mo Hassaballa Neil Artz Tariq Alhammali James Robinson Andrew Porteus James Murray

Introduction

The legion knee revision system was designed as a follow and improvement to the Genesis II knee system- allowing for a surgeon directed femoral rotation as opposed to the in-built femoral rotation in the previous system.

This is a prospective review of consecutive patients who underwent knee revision surgery using the legion knee system.

Methods

Clinical and functional assessments were carried out preoperatively, one year and 2 years post op. Radiographic evaluation was done at 1 and 2years follow up. Standard knee scoring systems (American Knee Scores-AKS, and Oxford score were used for the clinical and functional evaluation of these patients. The WOMAC score was also used to assess for pain, stiffness and social function in these patients. The radiographic assessment included review of standing AP, lateral and skyline views. Figgie's method was used to measure the joint line reproduction. A difference of 5 mm (pre = op/post-op) was deemed satisfactory.


Reinhard Stoewe Nathan Wayne

Introduction

The anterior mini-invasive approach to performing total hip arthroplasty (THA) is associated with less soft tissue damage and a shorter postoperative recovery than other methods. In August 2008, our hospital abandoned the traditional lateral Hardinge approach in favor of this new method. The purpose of this study was to measure changes in short-term clinical and radiological results and complications after the changeover.

Methods

We compared the first 100 patients operated after the changeover to the new method (MI group) to the last 100 patients operated using the traditional method (LH group). Clinical and radiological parameters and complications were recorded pre- and postoperatively and the collected data of the two groups were statistically analyzed and compared.


Nina Erdmann Janin Reifenrath Nina Angrisani Arne Lucas Hazibullah Waizy Fritz Thorey Andrea Meyer-Lindenberg

Magnesium calcium alloys are promising candidates for an application as biodegradable osteosynthesis implants [1,2]. As the success of most internal fracture fixation techniques relies on safe anchorage of bone screws, there is necessity to investigate the holding power of biodegradable magnesium calcium alloy screws. Therefore, the aim of the present study was to compare the holding power of magnesium calcium alloy screws and commonly used surgical steel screws, as a control, by pull-out testing.

Magnesium calcium alloy screws with 0.8wt% calcium (MgCa0.8) and conventional surgical steel screws (S316L) of identical geometries (major diameter 4mm, core diameter 3mm, thread pitch 1mm) were implanted into both tibiae of 40 rabbits. The screws were placed into the lateral tibial cortex just proximal of the fibula insertion and tightened with a manual torque gauge (15cNm). For intended pull-out tests a 1.5mm thick silicone washer served as spacer between bone and screw head. Six animals with MgCa0.8 and four animals with S316L were followed up for 2, 4, 6 and 8 weeks, respectively. Thereafter the rabbits were sacrificed. Both tibiae were explanted, adherent soft tissue and new bone was carefully dissected around the screw head. Pull-out tests were carried out with an MTS 858 MiniBionix at a rate of 0.1mm/sec until failure of the screw or the bone. For each trial the maximum pull-out force [N] was determined. Statistical analysis was performed (ANOVA, Student's t-test).

Both implant materials were tolerated well. Radiographically, new bone was detected at the implantation site of MgCa0.8 and S316L, which was carefully removed to perform pull-out trials. Furthermore, periimplant accumulations of gas were radiographically detected in MgCa0.8. The pull-out force of MgCa0.8 and S316L did not significantly differ (p = 0.121) after two weeks. From 6 weeks on the pull-out force of MgCa0.8 decreased resulting in significantly lower pull-out values after 8 weeks. Contrary, S316L pull-out force increased throughout the follow up. Thus, S316L showed significantly higher pull-out values than MgCa0.8 after 4, 6 and 8 weeks (p<0.001).

MgCa0.8 showed good biocompatibility and pull-out values comparable to S316L in the first weeks of implantation. Thus, its application as biodegradable osteosynthesis implant is conceivable. Further studies are necessary to investigate whether the reduced holding power of MgCa0.8 is sufficient for secure fracture fixation. In addition, not only solitary screws, but also screw-plate-combinations should be examined over a longer time period.

Acknowledgements

The study is part of the collaborative research centre 599 funded by the German Research Foundation.


Marius Keel Lorin Benneker Ulrich Seidel Klaus Siebenrock Johannes Bastian

Introduction

Significant access morbidity with intercostal neuralgia and post-thoracotomy pain syndrome was reported in case that an anterior approach for spondylodesis of fractures of the thoracolumbar spine was used. We describe our experience with thoracoscopical fusion from anterior as a less invasive approach.

Patients

Between 02/2007 and 09/2008 in a series of 32 patients (18 male; mean age 43, 17–74yrs) with fractures of the thoracolumbar spine (level Th11: n = 2, level Th12: n = 12, level L1: n = 18; fracture types: A3.1.1: n = 15, A3.2.1: n = 11, A3.3.1: n = 3, B2.1: n = 1 and B2.3: n = 2) thoracoscopical fracture stabilization was performed. A less invasive approach with three portals without an assistant was used facilitated by a new retractor system. In 16 patients fracture stabilization from anterior was supported by an additional spondylodesis using an dorsal approach. For reconstruction of the anterior column a VLIFT-system (n = 19), a Synex- (n = 11) or a Harms-Cage (n = 2) in combination with a MACS-TL (n = 16) or a Arcofix-system (n = 2) were used.


Eduardo Carrera Adriano Marchetto Fernando Reis

Introduction

The aim of this study is to present the results of the surgical treatment of the humeral neck fracture applying two different plates based on the presence or not of bone compression.

Material and Methods

Thirty two patients with displced proximal humerus fracture were operated on between January 2002 and August 2007. After radiographic analysis, the fractures were classified into two types: non-compressive (without loss of bone tissue – not impacted fracture) and compressive (with permanent bone loss due to compression between the fragments – impacted valgus fracture) fractures. Depending on the presence or not of bone compression, two different plates were applied for osteosynthesis: a locking angled blade plate, for “non-compressive fractures” and a locking angled “spacer” plate, for “compressive fractures”.


Farshad Adib Firouz Medadi Eric Guidi Armin Alami Harandi Chandra Reddy

Introduction

In this study we decided to observe the incidence of osteoarthritis following ORIF of Lisfranc joint injury. We also intended to point out the influence of different factors such as late diagnosis of the fracture, co-fractures, and open or close fractures on the incidence of osteoarthritis.

Methods

Patients with a dislocation more than 2 millimeters in simple AP, lateral and oblique radiograms of the foot who went through ORIF were included. Patients were classified according to: Anatomic or non-anatomic reduction, open or close fractures, presence of other fractures and early or late diagnosis (up to 6 weeks). The incidence of osteoarthritis was then compared in these groups.


Renata Pospischill Julia Weninger Alexandra Pokorny Johannes Altenhuber Rudolf Ganger Franz Grill

Background

Several risk factors for the development of osteonecrosis following treatment of developmental dislocated hip have been reported. The need for further research with a large-enough sample size including statistical adjustment of confounders was demanded. The purpose of the present study was to find reliable predictors of osteonecrosis in patients managed for developmental dislocation of the hip.

Methods

A retrospective cohort study of children, who have been hospitalized at our department between January 1998 and February 2007 with a developmental dislocation of the hip, was completed. Sixty-four patients satisfied the criteria for inclusion. Three groups according to age and treatment were identified. Group A and B included patients treated with closed or open reductions aged less than twelve months. Patients of group C were past walking age at the time of reduction and were treated by open reduction combined with concomitant pelvic and femoral osteotomies. The average duration of follow-up for all patients was 6.8 years. Logistic regression analysis was conducted to identify predictors for the development of osteonecrosis.


Philippe Boisrenoult Julien Berhouet Philippe Beaufils Dominique Frasca Nicolas Pujol

Introduction

Proper rotational alignment of the tibial component in total knee arthroplasty (TKA) could be achieved using several techniques. The self adjustment methodology allows the alignment of the tibial component under the femoral component after several flexion-extension movements. Our hypothesis was that this technique allowed a posterior tibial component alignment parallel to the femoral component posterior bicondylar axis. The aim of this study was to access this hypothesis using a post-operative CT-scan study.

Materials and Methods

This prospective CT-scan study involved 94 TKA. Theses TKA were divided in two groups: group1: 50 knees with a pre-operative genu varum deformity (mean HKA: 172.2°), operated using a medial parapatellar approach, and group 2: 44 knees with a preoperative valgus deformity (mean HKA: 188.7°), operated using a lateral parapatellar approach. Four measures were done on each post-operative CT-scan: angle between anatomical transepicondylar axis and femoral component posterior bicondylar axis (FCPCA), angle between FCPCA and tibial component marginal posterior axis, angle between tibial component marginal posterior axis and bony tibial plateau marginal posterior axis (BTPMPA), angle between transepicondylar axis and tibial component marginal posterior axis. Each measure was repeated, after one month by the same independent observer. Statistical evaluation used non-parametric Wilcoxon–Mann–Whitney test to compare each group of measures, and intraobserver reproducibility was assessed using ANOVA test, with an error rate of 5%.


Eric Petroff Eric Petroff Stephane Audebert Jean Michel Delobelle

We evaluated the results of Cementless Surface Replacement Arthroplasty (CSRA) of the shoulder in 67 patients with advanced glenohumeral destruction who have an intact rotator cuff.

Between november 2002 and december 2008, 70 CSRA (32 Copeland/ Biomet and 38 SMRR/ Lima) were implanted in 67 patients. A deltopectoral approach was used in 34 cases and an anterosuperior approach in 36 cases. Patients were assessed using Constant score, a patient satisfaction score and a detailed radiographic analysis. The mean follow up was 3.4 years (range 1 to 7.5 years).

The mean Constant score improved preoperatively from 17.6 points (range 2–55) to an average postoperative score of 66.1 (range 13–91). The pain score improved from 1.13 points (range 0–6) to 12.3 points (range 3–15). The forward flexion and external rotation improved from 71° (range 20 to 140) and 0° (range −40 to +45) to 143° (range 60 to180) and 34.4° (range −20 to +60) respectively.

Complications included: 1 subscapularis detachment, 5 secondary rotator cuff tear, 1sepsis, 3 patients with shoulder stiffness.

No shift in implant position was observed. 11 humeral components developed radiolucencies at the prosthesis-bone interface. The radiographic analysis involved a system of dividing the prosthesis/bone interface into 5 zones.

The best clinical results were significantly achieved in patients with necrosis compared with osteoarthritis (Constant Score, ant. elevation, ext. Rotation).

Using regression analysis we found that changes in the head-shaft angle position of the implant (valgus/varus placement of the CSRA) significantly predicted the age and sex adjusted Constant score. When the inclination angle of the humeral head decreases, the adjusted Constant score increases. In the same model, we also found that the lateral offset of the humerus significantly predicted the adjusted Constant score. When the lateral offset of the humerus decreases, the adjusted Constant score increases.

The medialization of the glenoid significantly and negatively predicted the Constant score.

Conclusion

CSRA of the shoulder outcomes have been comparable with those of stemmed arthroplasties. Radiolucent lines occur with follow up and most of the time located in the S1 area. Glenoid wear and humeral head lateralization negatively impact the clinical score. Cementless Shoulder resurfacing is a viable alternative to conventional shoulder arthroplasty.


Luc Favard Allan Young Ghassan Alami Daniel Mole Francois Sirveaux Pascal Boileau Gilles Walch

Purpose

to analyze the survivorship of the RSA with a minimum 10 years follow up.

Patients and Methods

Between 1992 and 1999, 145 Delta (DePuy) RSAs have been implanted in 138 patients. It was a mulicentric study. Initial etiologies were gathered as following: group A (92 cases) Cuff tear arthropaties (CTA), osteoarthritis (OA) with at least 2 involved cuff tendons, and massive cuff tear with pseudoparalysis (MCT); group B (39 cases) -failed hemiarthroplasties (HA), failed total shoulder arthroplasties (TSA), and fracture sequelae; and group C (14 cases) rheumatoid arthritis, fractures, tumor, and instability. Survival curves were established with the Kaplan-Meier technique. Two end-points were retained: -implant revision, defined by glenoid or humeral replacement or removal, or conversion to HA; - a poor clinical outcome defined by an absolute Constant score of less than 30.


Patrick Sadoghi Patrick Vavken Andreas Leithner Peter Müller Josef Hochreiter Georg Weber

Introduction

Insufficient arthroscopic cuff tear reconstruction leading to massive osteoarthritis and irreparable rotator cuff tears might be salvaged by implantation of an inverted total shoulder prosthesis Delta in the elderly. However, despite the generally high success rate and satisfying clinical results of inverted total shoulder arthroplasty, this treatment option has potential complications. Therefore, the objective of this study was a prospective evaluation of the clinical and radiological outcome after a minimum of 2 years follow-up of patients undergoing inverted shoulder replacement with or without prior rotator cuff repair.

Patients and Methods

Sixty-eight shoulders in 66 patients (36 women and 30 men) operated between February 2002 and June 2007 with a mean age of 66 years (ranging from 53 to 84 years) were first assessed preoperatively and then at minimum 2 years follow-up, using the Constant score for pain, Constant Shoulder Score, Oxford Shoulder Score, UCLA Shoulder rating scale, DASH Score, Rowe Score for Instability and Oxford Instability Score. 29 patients (Group A) had undergone previous shoulder arthroscopy for cuff tear reconstruction at a mean of 29 months (range 12 to 48 months) before surgery and 39 patients (Group B) underwent primary implantation of an inverted total shoulder prosthesis Delta. Any complications in both groups were assessed according to Goslings and Gouma.


Jan-Erik Gjertsen Jonas Fevang Tarjei Vinje Kjell Matre Lars Birger Engesaeter

Introduction

Undisplaced femoral neck fractures have been given little attention in the literature. By using data from the Norwegian Hip Fracture Register, this study investigates risk for reoperation and the clinical results, including pain, patient satisfaction, and quality of life, after undisplaced femoral neck fractures in elderly patients.

Material and Methods

Data on 4,468 patients over 70 years of age with undisplaced femoral neck fractures operated with internal fixation (IF) were compared to 10,289 patients with displaced femoral neck fractures treated with IF (n = 3,389) or bipolar hemiarthroplasty (n = 6,900). The evaluation was based on number of reported reoperations and patients' assessment (visual analogue scales concerning pain (0–100) and patient satisfaction (0–100), and quality of life (EQ-5D)) four and twelve months postoperatively. The patients were followed for 0–1 year. The Cox multiple regression model was used to construct adjusted survival curves. Subanalyses were performed on undisplaced femoral neck fractures to investigate different risk factors for reoperation.


Stefan Bajada Gareth Roberts Rhodri Gwyn Michelle Palmer Hilton Fanarof Owain Ennis

Introduction

Neck of femur (NOF) fractures are one of the predominant reasons for hospital admissions in patients >65 year. These fractures are associated with a poor outcome; end to independent living in 60% of patients and a 6 month mortality of 30%. Previous studies have shown show elements of under/mal-nutrition on admission. In addition, their nutritional status shows some deterioration thereafter. The aim of this present study is to examine if the nutritional status of patients with NOF fracture admitted at our institution is associated with a larger post-operative haemoglobin drop. This is compared to an independent living age matched control group from the same geographical area.

Methods

A retrospective audit of pathology results for three hundred fracture patients (n = 300) and one hundred age matched home living group pre-assessed of total hip replacement (n = 100). Total serum protein, albumin, total lymphocyte count levels were determined at the time of admission to assess nutritional status. Pre/post-operative haemoglobin, resultant haemoglobin drop, and 6 month mortality was assessed in NOF fracture patients. The nutritional parameters were correlated with the haemoglobin levels and mortality.


Tarjei Vinje Jan-Erik Gjertsen Stein Lie Lars Engesaeter Leif Havelin Ove Furnes Kjell Matre Jonas Fevang

Background

Systematic reviews disagree, but some recent studies have shown better function and less pain after operation with bipolar hemiarthroplasty compared to fixation by two screws in elderly patients operated for displaced femoral neck fractures. There is still uncertainty regarding the mortality associated with both procedures.

Aim of the study

To investigate mortality and the risk factors for death among patients with displaced femoral neck fractures within the first three years after surgery, comparing operation with bipolar hemiarthroplasty (HA) and internal fixation (IF) by two screws.


Stefan Bajada Paul Harrison Ali Mofidi James Richardson

Introduction

Regenerative medicine is a rapidly expanding discipline. However due to a lack of validated outcome measures, clinical trials have been far few. This study aims to assess the validity, inter-observer reliability and intra-observer reproducibility of experimental fracture healing assessment on plain radiographies. This technique involves implantation of mesenchymal stem cell (MSC) seeded constructs on only one side of the fracture after randomisation.

Methods

We examined inter/intraobserver agreement on the area and “bridging length” of callus formed on opposite sides of the fracture. Among 16 orthopaedic surgeons with trauma commitments (8 consultants, 8 registrars) on two separate occasions (average 52 days apart). They independently assessed the radiographs (AP or lateral) of 28 patients with fractures of the tibial or femoral shaft. The fractures chosen included non-unions treated with MSC/constructs and fresh fractures at 4–9 months. For each radiograph the assessor assigned which side (medial or lateral) is there more callus. Chase-corrected agreement using Fleiss kappa was used to compare opinions. Digital analysis software (Image-J) was used to quantify extent/bridging callus and correlate it with surgeons opinion.


Tarjei Vinje Jonas Fevang Lars Engesaeter Stein Lie Leif Havelin Kjell Matre Jan-Erik Gjertsen Ove Furnes

Background

A well conducted randomised study found similar functional results for patients with displaced femoral neck fracture comparing operation with a modern uncemented bipolar hemiarthroplasty with a cemented bipolar hemiarthroplasty. The mortality associated with the two procedures has not been sufficiently investigated.

Aim of study

To investigate the mortality and the risk factors for death among patients with displaced femoral neck fractures the first year after surgery, comparing operation with modern uncemented and cemented bipolar hemiarthroplasty (HA).


Jan-Erik Gjertsen Tarjei Vinje Jonas Fevang Stein Atle Lie Ove Furnes Leif Ivar Havelin Lars Birger Engesaeter

Introduction

Displaced femoral neck fractures in elderly are normally treated with 2 screws/pins (IF) or bipolar hemiarthroplasty (HA). The aim of this study was to compare IF and HA as treatment for displaced femoral neck fractures using reoperations and functional result (patient satisfaction, pain, and quality of life) as outcome.

Material and Methods

From January 2005 all hip fractures in Norway are reported to the Norwegian Hip Fracture Register. At 4, 12, and 36 months postoperatively a questionnaire assessing satisfaction (VAS 0-100), pain (VAS 0-100), and quality of life (EQ-5D) is sent to the patients. To ensure more than 3 years follow-up, only patients operated in 2005 were included in the present study. Consequently 1,968 patients over 70 years of age operated with IF (n = 958) or HA (n = 1,010) due to displaced femoral neck fractures were included in the analyses on reoperations. Of these, 280 patients responded to all questionnaires and were included in the analyses on functional results (IF: n = 135, HA: n = 145). The patients remained in the same treatment group according to the intention-to-treat principle.


Wilhelm Friedl John Wright

The avulsion fracture of the V-th metatarsal and Jones fractures often show delayed and non-union. The tension belt osteosynthesis shows often soft tissue problems due to the thin soft tisshe covering. A new minimal invasive method with the 3,5mm XXS nail and the clinical results are presented.

Percutaneously the fracture is reduced with a K-wire as a joy stick. This or if the direction needed is different a second K-wire as guide is introduced and with a canulated 3,5 mm drill the place for the nail is prepared. Proximal and distal to the fracture one threaded wire locking and fracture compression through the nail (proximal longitudinal holes) are performed.

77 patients with a XXS nail fixation of MT V fractures were treated from July 1999 to Jan.2006. Clinical and radiological re-examination at 1 to 6 years were performed. The AOFAS was 22 pre- and 96 postoperatively. No pseudarthrosis but in 53 patients implant removal was done in part due to local discomfort. This was strictly correlated to the length of the threaded wires to the bone surface. 95% reached pretrauma activity levels. Satisfaction was 9 from 10 points.

The XXS nails allow a percutaneous stable fixation of the avulsion and Jones fractures of the V-th metatarsus. The complication rate is low.


Michelle Griffin Syed Iqbal Anil Sebastian James Colthurst Ardeshir Bayat

Introduction

Nonunions pose complications in fracture management that can be treated using electrical stimulation (ES). Bone marrow mesenchymal stem cells (BMMSCs) are essential in fracture healing, although the effects of different clinical ES waveforms available in clinical practice on BMMSCs cellular activities is unknown.

Materials and Methods

We compared Direct Current (DC), Capacitive Coupling (CC), Pulsed Electromagnetic wave (PEMF) and Degenerate Wave (DW) by stimulating human-BMMSCs for 5 days for 3 hours a day. Cytotoxicity, cell proliferation, cell-kinetics and cell apoptosis were evaluated after ES. Migration and invasion were assessed using fluorescence microscopy and affected gene and protein expression were quantified.


Wilhelm Friedl Sagar Singh Andrei Anastasiu

Distal radius fractures are typical and frequent fracture of elderly woman with reduced bone density. Thus implant fixation is more difficult. Dorsal and radial comminution are frequent in these patients and so reduction and angle stable osteosynthesis needed. The angle stable plate, often also multidirectional is today the most common stabilisation device. Because of the introduction of bulky and bended implants as the Micronail or Targon DR wich require difficult opening of the bone with awles we decided to test the XS radius nail witch is a 4,5mm or 3,5mm straight nail and witch is introduced after guide wire placement and over drilling with a canulated drill of the same diameter. It is locked parallel to the joint in 3 different directions with angular stability with threaded wires.

Methods 16 radius sawbones were osteotomised corresponding to a A3 Fracture and stabilised with a angle stable plate (8) and XS nail (8). 1000 alternating load cycles from 20–200N were performed and the deformation was registered. Also a FE analysis with the MSC Patran/Marc softwere were performed.

Also the calculated deformation in the FE study was 20% lower. Also deformation amplitude was lower with 0.31mm compared to 0.42mm in the plate group. The differences however were not significant.

Both devices show good biomechanical results. The XS nail has the advantage of mainly intraosseus position, simple operation technique with introduction over a guide wire from the proc. Styloideus radii and over drilling with a canulated drill of the same size. The exposure of the N rad. superf. must be performed. First clinical evaluation is presented.

Due to the results we developed a anatomically adapted XS radius nail. The results of the first 100 patients are presented.

Conclusions

Both angular stable plate and XSR nail can be used in unstable distal radius fracture fixation.

The mainly intraosseus position of the nail and saving of the pronator quadratus as well as lower deformation are in favour of the XSR nail.

However frontal plane fractures and very comminuted fractures are better treated with a multidirectional locking plate due to technical reasones so that we use the XSR nail mainly in A3 and C1 fractures.


Wilhelm Friedl Jonas Gehr

Clinical Problem

Pilon fractures and distal metaphyseal fractures of the tibia are associated with a high rate of soft tissue and bone healing problems.

We started to use the XS and XS nail as minimal invasive procedure for the management of these fractures in July 2000 first for the fibula and since for the fibula and pilon itself but extended metaphseal comminution are contraindication for the XS nail.

Because of soft tissue problems and higher loading capacity of intramedullary implants the XS Nail was also used for ankle fracture osteosynthesis but as in all articular fractures with open reduction,

Material and Methods

the XS nail is a 4.5mm or the XXS a 3.5mm straight nail witch is locked by threaded wires witch are placed with an aiming device and allows also dynamic fracture site compression with a set screw. The Fibula is fixed percutaneusly and after distal locking with traction of the aiming device also tibia length and axis can be restored and fixed with the proximal locking. From july 2000 to july2006 54 pilon fractures where treated. The mean age was 54 years (range 25–92). In all cases except one referred after 4 weeks the fibula and joint dislocations where stabilised primarily. The tibia XS nail osteosynthesis or limited invasive plate fixation was performed after 5–8 days except two fixed primarily. Up to now 43 patients could be re-examined more than 12 months after surgery. The results were classified according to the Ovadia Score.

In a second study: from 05/2000 to 03/2002 214 ankle fractures were stabilised with a XS or XXS nail. The mean age was 51 year, 59% were woman. 35% were Weber B and 25% type C fractures. The re-examination after 6 months could be performed in 91 Patients and was evaluated according to the Ovadia score (clinical and radiological).


Jeppe Rasmussen Anne Kathrine Sorensen Bo Olsen

Objective

To describe demographic data, clinical outcome and short-term survival after shoulder arthroplasty.

Materials and Methods

The Danish Shoulder Arthroplasty Register was established in 2004. All 40 Danish hospitals and private clinics where shoulder arthroplasty are performed are participating.

Since 2006 where the reporting to the register became mandatory the compliance of reporting has been 88.9%. Data are collected by an internet based clinical measuring system where the orthopaedic surgeon report data such as diagnosis, type of arthroplasty, and demographic data. The follow-up results are collected by sending a questionnaire to the patient 10–14 month after the operation. The questionnaire contains a Western Ontario Osteoarthritis of the Shoulder index (WOOS). Each question is answered on a visual analogue scale with a possible score ranging from 0–100. There are 19 questions and the total score is ranging from 0–1900. For simplicity of presentation the raw scores is converted to a percentage of a normal shoulder.


Full Access
George Smith Paul Appleton Charles Court-Brown Margaret Mcqueen Tim White

Introduction

The optimal treatment of elderly patients with unstable ankle fractures is a widely contested and as yet unresolved issue. Whereas the AO technique of anatomical reduction and plate fixation has been shown to give good functional results it is associated with a wound complication rate of up to 40%. This has led some surgeons to believe the risks of operative intervention are too great.

The fibula nail is an intra-medullary device with the benefit of requiring minimal soft-tissue dissection. It provides lateral column support over a greater area than the standard plate.

The study aims were to assess the clinical and radiographic outcome of a cohort of patients managed with the Fibula Nail (Acumed).

Methods

A prospectively collected group of 36 patients with an unstable Weber B or C fracture were managed with a fibula nail. Outcome measures at one-year follow-up were Olerud and Molander ankle scores, radiographic measurements and complications.


Jeppe Rasmussen Bo Zerahn Anders Paulsen Kim Andersen Anne Kathrine Sorensen Bo Olsen

Objective

To compare regional body composition, bone mineral density (BMD), and clinical outcome in patients with two different shoulder arthroplasty designs.

Materials and Methods

This cross-sectional study included 54 patients with a total of 63 shoulder arthroplasties. There were 18 men and 45 women with a mean age of 68.9 years SD ± 10.5. Mean follow-up time was 39.2 months SD ± 14.4. The patients were divided into three groups according to their history: 22 patients were diagnosed with a proximal humeral fracture and treated with a stemmed hemi arthroplasty, 11 patients were diagnosed with osteoarthritis and treated with a stemmed hemi arthroplasty, and 30 patients were diagnosed with osteoarthritis and treated with a resurfacing arthroplasty. All patients underwent a one-day protocol: Regional Dual X-ray Absorptiometri (DXA) was used to measure BMD of the distal third of humerus and regional body composition of the upper arm. The clinical outcome was measured using Western Ontario Osteoarthritis of the Shoulder index (WOOS) and Constant-Murley score.


Myung Chul Lee Sang Min Lee Sang Cheol Seong Sahnghoon Lee Jak Jang Joon Kyu Lee Sang Ho Shim

Summary

UC TKA showed similar anteroposterior translation and more femoral external rotation of earlier onset when compared to PS TKA.

Introduction

Recently highly conforming ultracongruent TKA has been reintroduced with improved wear characteristics and lower complications. The purpose of the study was to assess kinematics and clinical outcome of posterior stabilized and ultracongruent rotating-platform mobile bearing TKA.


Arndt Schulz Nina Kociz Vinzenz Burgherr Annika Homeier Nils Reimers Christian Jürgens

Bone shape variability within a specific population has been seldom investigated and used to optimize implant design. There is insufficient anatomical fitting of the existing prebend periarticular plates for the distal fibula. We developed a methodology for design of orthopaedic implants that fit a maximum percentage of the target population, both in terms of geometry and biomechanical stability. In co-operation with an implant manufacturer and different academic institutions, a virtual bone database has been developed that contains anatomical data of more than 1000 CT datasets with the implemented possibility to generate idealized implant fits for different anatomical sites. This program (Stryker Virtual Bone Database (VBD) is able to generate statistical anatomical shapes for different populations like age groups or ethnical groups. Based on this, an implant for the distal fibula has been developed (VariAx Distal Lateral Fibula Locking Plate) for distal fibula fracture treatment. Aim of this study was to develop and validate an implant that is optimized for the specific anatomical area. It should be precontoured and still fit to the majority of patients sustaining a distal fibular fracture. Another objective was to create a distally tapered design as there is less soft tissue cover in that anatomic area.

Materials & Methods

ProE CAD system was used in combination with the Bone Database (VBDB) to evaluate the bone shape of the target population plate shape. Several bones (from CT scans) have been used in a first validation process in comparison with an implant already available on the market (SPS Fibula Plate). Additionally, the results have been verified with a bone fitting study which was conducted in collaboration with the Maurice E. Müller Institute (MEM) in Bern/Switzerland. In a second step, the finished implant design was validated against statistical bone shapes of populations of different ethical origin.

Results

The comparison of the new Plate's shape with real bone data confirmed that the neutral form does cope with the anatomic situation laterally which means that no systematic pre-bending of the plate is required. Comparing with a conventional implant, the new implant could have been implanted unbend in 6 of 7 cases of virtual matching with real patient datasets compared to none with the conventional implant. The validation of statistical datasets of different ethnical origin (Caucasian, Asian) showed no statistical difference of implant mismatch.


Muhammad Sultan Muhammad Sultan Steven Fazakerley Ghazal Hodhody Nasser Kurdy Charles Mccollum

Introduction

Long-term ankle pain, stiffness or swelling are frequent following ankle fracture. We investigated whether engineered compression stocking (ECS) influenced functional outcome and quality of life (QoL).

Methods

Ninety patients < 72 hours following ankle fracture, (59 conservative and 31 operative fixation) were randomised to i) ECS + air-cast boot or ii) air-cast boot alone. Patients were followed at 2, 4, 8, 12 weeks and 6 months for Olerud Molander Ankle Score (OMAS), American Orthopaedic Foot and Ankle Score (AOFAS) and SF12v2 score with duplex imaging for deep vein thrombosis (DVT) at 4 weeks. 22 controls managed by plaster of paris (POP) were also assessed at 6 months only.


Ana Douglas Price Nicolas Cuestas Guillermo Cambiaggi Maria Vazquez Horacio Caviglia

Objective

To assess the beneficial use of polypropylene mesh impregnated with vancomycin in an experimental model open fractures Gustilo IIIa in rabbits.

Material and Method

We worked with 15 New Zeland White rabbits. All of them were carried out under general anaesthetic, a 5-cm incision longitudinal was made at the back of the right thigh. The femur was aproached and a fracture was performed with a shear, giving rise to a multifragment fracture. The wound remained open for 6 hours with the bone exposed, in a non-surgical ambient. Subsequently underwent surgical cleaning of the open fractures in two stages. The fracture was stabilized with an intramedular pin. The animals were sorted in 3 different therapeutic groups:

Group 1: (5 rabbits) without other treatment.

Group 2: (5 rabbits) a polypropylene mesh was placed around the fracture.

Group 3: (5 rabbits) a polypropylene mesh with vancomycin was placed around the fracture.

The wound was closed with nylon stiches.

Three weeks postoperative, the animals were intervened surgically under general anesthesia, after aseptic cure and placement of surgical fields, femoral bone biopsies, soft tissue and mesh were taken. The rabbits were sacrified. The samples were sent to pathology and bacteriology labs.


Ana Douglas Price Hernan Blanchetiere Pemoff Pemoff Nicolas Cuestas Horacio Caviglia

Introduction

Monomicrobian necrotizing cellulitis affects the skin and subcutaneous tissue as starting point the deepest level of the superficial fascia. The pathogen inoculation is by skin disruption, abrasions, burns, injections or bites. The free base cocaine is used with homemade pipes that generate pulps fingers skin microabrasions. We present 3 patients (one bilateral) with cellulitis necrotizing of the thumb caused by pricking and dermoabrasive trauma secondary to different manipulation methods for drogue use.

Material and Method

Experience in 3 patients free base cocaine addicts treated in our Hospital. Medical examination shows febrile syndrome (corporal temperature over 38C), and elevation of heart rate. They present cellulitis in thumb's first and second phalanx, with thenar swelling and digital necrosis with abundant purulent discharged. All of them had a pricking trauma 36 to 48 hours before. They were under surgical intervention, by surgical cleaning with necrotic and devitalized tissue's debridement. In 3 of the 4 patients amputation of the distal phalanx was mandatory. Tissue and bone culture was made in all patients. Intravenous antibiotic was performed. Two patients miss total antibiotic treatment by early no medical discharged.


Mark Blyth Bryn Jones Julie Smith Phil Rowe

Electromagnetic navigation versus conventional Total Knee Arthroplasty: Clinical improvements Optical and electromagnetic (EM) tracking systems are widely used commercially. However in orthopaedic applications optical systems dominate the market. Optical systems suffer from deficiencies due to line of sight. EM trackers are smaller but are affected by metal. The accuracy of the two tracker systems has been seen to be comparable1. Recent advancements in optical navigated TKA have shown improved overall limb alignment, implant placement and reduce outliers when compared to conventional TKA2-4.

This study is the first RCT to compare EM and conventional TKA. Two groups of 100 patients underwent TKA using either the EM navigation system or the conventional method. Frontal, sagittal and rotational alignment was analysed from a CT scan. Clinical scores including Oxford Knee Score (OKS) and Knee/Function American Knee Society Score (AKSS) were recorded pre-op, and at 3 and 12 months post-op. 3 month data presented includes 180 patients (n = 90). The 12 months data presented includes 140 (n = 70).

The two groups had similar mean mechanical axis alignments (EM 0.31o valgus, conventional 0.15o valgus). The mechanical axis alignment was improved in the EM group with 92% within +/-3o of neutral compared to 84% of the conventional group (p = 0.90). The alignment of the EM group was improved in terms of frontal femoral, frontal tibial, sagittal femoral, sagittal tibial and tibial rotation alignment. However, only the sagittal femoral alignment was significantly improved in the EM group (p = 0.04). Clinically, both TKA groups showed significant improvements in OKS and AKSS scores between both pre-op to 3 month post-op and 3 months to 12 months post-op (p<0.001). The OKS and the AKSS knee score for the EM group was significantly better at 3 months post-op (OXS p = 0.02, AKSS knee p = 0.04). However there was no difference between the groups at 12 months. The mean pre-op range of motion (ROM) for both groups was 105o. This decreased to 102o in the EM group and 99o in the conventional group at 3 months. There was a significant improvement at 12 months post-op, EM = 113o (p = 0.012) and conventional = 112o (p = 0.026). There was no significant difference in ROM between the two groups at 3 or 12 months post-op.

Therefore the alignment outcome of the EM TKA group was improved compared to the conventional group. The EM group also showed clinical improvements at 3 months post-op however these were not seen again at 12 months post-op. ROM was seen to decrease at 3 months post-op but then significantly improve by 12 month post-op.


Stephen Morris Joseph Jelski Jonathan Alper Andrew Kelly

Introduction

Mortality rates following hip fracture are high. There are several scoring systems which aim to predict morbidity and mortality in hospital in-patients. The Nottingham Hip Fracture Score (NHFS) was devised to predict 30 day mortality following hip fracture.

Methods

All patients with hip fractures admitted over a 6 month period were reviewed. The NHFS was calculated for each patient and any associations between patient factors, NHFS, and outcome were investigated.


Stephen Morris Jeremy Loveridge Alexander Torrie David Smart Richard Baker Anthony Ward Timothy Chesser

Aim

Evaluate the outcome and complications of anterior pubic symphysis plating in the stabilisation of traumatic anterior pelvic ring injuries.

Methods

All patients who underwent pubic symphysis plating in a tertiary referral unit were studied. Fracture classification, type of fixation, complications, and incidence of metalwork failure were recorded.


Christian Fontaine Varenka Couturier-Bariatynski Christophe Chantelot Guillaume Wavreille

Dynamometric measurement of the grasp strength is commonly used in wrist assessment. On the other hand measurement of the pronation-supination (PS) strength has been few studied. The longitudinal forearm rotation needs integrity of the two radioulnar joints and of the antebrachial interosseous membrane. The strength developed during PS assesses also trophicity of pronator and supinator muscles. A PS dynamometer (Baseline ®, AREX) is now available for such measurements. The aims of this study were: 1) to study the best way to neutralize the shoulder movements of abduction-adduction, 2) to find the values of PS Strength in a healthy population, and 3) to study correlations between this PS force and several biometric items.

A first series of measurements des PS strength was performed thanks to the Baseline dynamometer in 8 people, in association with two devices neutralizing the shoulder movements of abduction-adduction, in repeated campaigns allowed the authors to determine and keep the better one for optimal measurements following campaigns.

To assess the normal values of PS Strength in a healthy population, 38 healthy volunteers from both genders and different ages, classified according their age class, from three different forearm position: neutral, from 90 ° of supination and 90 ° of pronation.

Finally, statistical analysis looked for correlations between PS strength and some biometric data.

Manipulations beginning from a neutral position of forearm were the most reliable. The mean strength within the whole studied sample (76 wrists, 17 male, 21 female) was 10.6 N.m (standard deviation SD 3.26) for the supination and 13.9 N.m (standard deviation 4.19) for the supination.

The dominant side exhibited a PS strength superior by 7.5% to that of the non-dominant side. Male gender, the height and weight of the body, forearm circumference displayed positive relationships with PS strength.

Mean values of PS strength, measured from a neutral forearm rotation and with the best device to neutralize the shoulder movements, in a healthy population of 38 volunteers, allowed the authors establishing reference values. They will allow precise comparisons between the values found in patients suffering from forearm and/or wrist pathology and the healthy population, taking into account the age, gender and hand dominance.


Edward Yates Lyndsey Highton Zuned Hakim Mike Woodruff

Introduction

More than 60% of patients presenting with a hip fracture have significant medical co-morbidities and a one year mortality rate between 14% and 47%. The rating scale for the American Society of Anaesthetists (ASA) is a reliable predictor of both surgical risk and mortality with ASA 4 patients having 100% mortality at one year.1,2

Aims

Our aim was to establish a mortality rate for fractured neck of femur patients at three months and twelve months, and to ascertain the mortality of patients with an ASA 4 grading. Ultimately, should we be operating on this high risk cohort of patients'. We also chose to analyse our current practice in the management of displaced intracapsular neck of femur fractures in patients 90 years of age and over.


Neil Jain Prash Jesudason Asim Rajpura Bisal Muddu Len Funk

Introduction

There are over 110 special tests described in the literature for clinical examination of the shoulder, but there is no general consensus as to which of these are the most appropriate to use. Individual opinion appears to dictate clinical practice. Rationalising which tests and clinical signs are the most useful would not only be helpful for trainees, but would also improve day to day practice and promote better communication and understanding between clinicians.

Methodology

We sent a questionnaire survey to all shoulder surgeons in the UK (BESS members), asking which clinical tests each surgeon found most helpful in diagnosing specific shoulder pathologies; namely sub-acromial impingement, biceps tendonitis, rotator cuff tears and instability; both anterior and posterior.


Julian Maempel Anthony Ward Tim Chesser Michael Kelly

Background

Tightrope fixation has been suggested as an alternative to screw stabilisation for distal tibiofibular joint diastasis that provides stability but avoids the problems of rigid screws across the joint. Recent case series (of 6 and 16 patients) have however, reported soft tissue problems and infections in 19–33% of patients. This study aims to review treatment and complications of distal tibiofibular diastasis fixation in our unit with the use of Tightrope or diastasis screws.

Methods

Retrospective review of all patients undergoing primary ankle fixation between May 2008 and October 2009. Exclusions included revision procedures, or ankle fixation prior to the current fracture. Those undergoing Tightrope or diastasis screw fixation were studied for any complications or further procedures. Clinical records and XRAYs were reviewed, family practitioners of the patients were contacted and any consultations for ankle related problems noted.


Julian Maempel Melanie Coathup Neville Calleja Tim Briggs Stephen Cannon Gordon Blunn

Background

Extendable partial femoral replacements (EPFR) permit limb salvage in children with bone tumours in proximity to the physis. Older designs were extended through large incisions or minimally invasive surgery. Modern EPFR are lengthened non-invasively. Lengthening improves functional score (Futani, 2006) but has been associated with complications including infection (Jeys, 2005). This study is the first to look specifically at the relationship between EPFR lengthening and complications.

Method

Retrospective review of 51 paediatric (<16 years) oncology patients undergoing primary (1 °) EPFR (minimally/noninvasive) between 06/1994 and 01/2006. Exclusions: 1 patient with 5cm extension without medical intervention and 5 patients with incomplete data.


Henrica Van Der Linden Henrica Van Der Zwaag Louise Konijn Tim Van Der Steenhoven Huub Van Der Heide Rob Nelissen

Introduction

Malrotation following total knee replacement is directly related to poor outcome. The knowledge of proximal and distal rotational axes and angles of the femur is therefore of high importance. The aim of the study was to determine whether the most used proximal and distal femoral angles; femoral anteversion angle (FAA) and posterior condylar angle (PCA) were different within individuals, between right, left and gender. As well, we studied whether the “inferior condylar angle” is correlated to the PCA and therefore useful in determining the rotation of the distal femur.

Material and Methods

From 36 cadavers the femora were obtained and after removing the soft tissue a Computed Tomography (CT) scan was made. Three angles were measured: (i) the FAA between femoral columnar line (FHNL) and posterior condylar line (PCL), (ii) the PCA between anatomical transepicondylar line (TEL) and PCL, (iii) the inferior condylar angle (ICA) between the TEL and inferior condylar line (ICL). Statistical analysis of comparative relationships between the different angles was examined by calculating correlation coefficients and a paired t-test.


Carles Esteve Carles Esteve Ignacio Garcia-Forcada Josep Gina

Introduction

Surgical site infections (SSI) are related to a surgical procedure and affect the surgical wound or deeper tissues. With continuing emphasis on clinical governance and quality control, there is increasing demand from both patients and government for methods of assessing surgical results. Rates of morbidity and mortality may play important roles in these assessments. When crude comparisons between hospitals in the incidence of SSI are made, these should at least be stratified by the type of procedure. The aim of this study is to fix SSI incidence in relation to surgical procedure.

Methods

This report contains data of 19.948 procedures collected from 1996 to 2008 at a Specialist Orthopaedic Hospital and analyzed by a specific software designed for the study of infection in orthopaedic and trauma surgery.

The SSI surveillance is focused on categories of surgical procedure (Hip Arthroplasty, Knee Arthroplasty, Spine Surgery and Hip Fracture Surgery) with each category containing a defined set of similar procedures. A basic of demographic data and details about operation itself are collected for each procedure. Patients are followed up throughout their hospital stay and after hospital discharge.

We present the incidence of SSI by risk group and surgical procedure. SSI are categorized in type, moment of diagnosis and micro-organisms reported.

Analysis of the data was performed (SPSSv15.0 ®). Statistical methods used to determine significance were the independent samples t test, Pearson X2 test, Odds ratio and Spearman correlation coefficient, with a significance level of p<0,05.


Jeppe Barckman Jorgen Baas Mette Sorensen Joan Bechtold Jeppe Lange Kjeld Soballe

Introduction

Hip and knee arthroplasty present surgeons with difficult bone loss. In these cases the use of morselized allograft is a well established way of optimizing early implant fixation. In revisions, the surgical field is potentially infected. The use of allograft bone creates a “dead space” in which the immune system has impaired access, and even a small amount of bacteria may therefore theoretically increase the risk of infection.

In vivo studies have shown that allograft bone is suitable as a vehicle of local antibiotic delivery.

We hypothesized that the allograft bone could be used as a local antibiotic delivery vehicle without impairing the implant fixation, tested by mechanical push-out.

Material and Methods

Following approval of the Institutional Animal Care and use Committee we implanted a cylindrical (10×6 mm) porous-coated Ti implant in each distal femur of 12 dogs observed for 4 weeks. The implants were surrounded by a circumferential gap of 2.5 mm impacted with a standardized volume of morselized allograft. In the two intervention groups, 0.2ml tobramycin solution of high (800mg/ml) and low (200mg/ml) concentration was added to the allograft, respectively. In the control group 0.2ml saline was added to the allograft.

ANOVA-test was applied followed by paired t-test where appropriate. A p-value < 0,05 was considered statistically significant.


Arno Martin Johannes Cip Eckhart Mayr Thomas Benesch Roman Waibel Archibald Von Strempel Mark Widemschek

Background

Computer-assisted navigation systems for total knee arthroplasty (TKA) were introduced to improve implantation accuracy and to optimize ligament balancing. Several comparative studies in the literature confirmed an effect on the component position and other studies could not confirm these results. For ligament balancing most studies found no significant influence on the clinical outcome using a navigation system for TKA. In the literature there were no reports of mid-term results after navigated TKA. With our study we wanted to show if the use of a navigation system for TKA will have an influence on the component's position and on the clinical results at 5-year follow up.

Methods

We enrolled 200 patients in a prospective randomized study with a minimum follow up of 5 years. 100 TKA were operated on without using a navigation system (Group A) and 100 surgeries (Group B) were done with computer assistance.

Radiological investigation by standard radiographs including a long-leg X-ray was performed with a follow up rate in Group A of 86.2% versus 80.2% in Group B. We measured the mechanical axis of the leg, lateral distal femoral angel (LDFA), medial proximal tibial angle (MPTA), tibial slope and the alpha-angle of the patella. Clinical investigation was performed with a follow up rate in Group A of 85.7% versus 79.8% in Group B including the parameters for the range of motion (ROM), ligament balancing, anterior drawer test, feeling of instability, anterior knee pain, effusion, WOMAC Score, Insall Score and HSS Knee Score.


Anne Lübbeke Davide Salvo Nicolas Holzer Pierre Hoffmeyer Mathieu Assal

Introduction

Among patients with ankle osteoarthritis (OA) a post-traumatic origin is much more frequent than among those with knee or hip OA. However, long-term studies evaluating risk factors for the development of OA after ankle fractures are lacking.

Methods

Retrospective cohort study including consecutive patients operated at our institution between 1/1988 and 12/1997 for malleolar fractures treated with open-reduction and internal fixation (ORIF). Ankle OA was independently assessed by two reviewers on standardized radiographs using the Kellgren and Lawrence (K&L) scale. Multivariate logistic regression analysis was performed to determine predictors for OA.


Jacob Cartner Zane Hartsell Paul Cooper William Ricci Paul Tornetta III

Introduction

Conventional screws achieve sufficient insertion torque in healthy bone. In poor bone screw stripping can occur prior to sufficient torque generation. It was hypothesized that a screw with a larger major/minor diameter ratio would provide improved purchase in poor bone as compared to conventional screws. We evaluated the mechanical characteristics of such a screw using multiple poor bone quality models.

Methods

Testing groups included: conventional screws, osteopenia screws used in bail-out manner (ie, larger major/minor diameter screws inserted into a hole stripped by a conventional screw), and osteopenia screws used in a preemptive manner (ie, no screw stripping occurrence).

Stripping Torque: Screws were inserted through standard straight plates into a low density block of foam with a predrilled hole. Stripping torque was defined as maximum insertion torque reached by the screw before the screw began to spin freely in the foam.


Henri Migaud Michael Amzallag Gilles Pasquier Francois Gougeon Laurent Vasseur Bruno Miletic Julien Girard

Introduction

In valgus knees, ligament balance remain difficult when implanting a total knee arthroplasty (TKA), this leads some authors to systematically propose the use of constrained devices. Others prefer reserving higher constraints to cases where it is not possible to obtain final satisfactory balance: less than 5 of residual frontal laxity in extension in each compartment, and a tibiofemoral gap difference not in excess to 3mm between flexion and extension. The goal of the study was to assess if is possible to establish preoperative criteria that can predict a constrained design prosthetic implantation at surgery.

Materials and Methods

A consecutive series of 93 total knee prostheses, implanted to treat a valgus deformity of more than 5 was retrospectively analysed. Preoperatively, full weight bearing long axis AP views A-P were performed: hip knee angle (HKA) averaged 195 (186 to 226), 36 knees had more than 15 of valgus, and 19 others more than 20 of valgus. Laxity was measured by stress radiographies with a TelosTM system at 100 N. Fifty-two knees had preoperative laxity in the coronal plane of more than 10. Fourteen knees had more than 5 laxity on the convex (medial) side, 21 knees had more than 10 laxity on the concave (lateral) side.

Statistical assessment, using univariate analysis, identified the factors that led, at surgery, to an elevated constraint selection level; these factors of independence were tested by multivariate analysis. Logistical regression permitted the classification of the said factors by their odds ratios (OR).


Satoru Demura Norio Kawahara Hideki Murakami Yoshiyasu Fujimaki Satoshi Kato Yoshiyuki Okamoto Hiroyuki Hayashi Kei Inoue Hiroyuki Tsuchiya

Introduction

Correction and arthrodesis for cervical kyphosis associated with atetoid cerebral palsy has been considered to be difficult because of their involuntary neck movements and severe deformity. The aim of this study is to evaluate the surgical outcome of midline T-saw laminoplasty and posterior arthrodesis using pedicle screws.

Methods

15 patients were retrospectively reviewed. There were 6 women and 9 men, with a mean age 52.9 years (range 31–71 years). Mean follow-up period was 43 months (range 24–84 months). For clinical evaluation, the Japanese Orthopaedic Association (JOA) score and Barthel index (BI) which shows independence in ADL were used. For radiographic evaluation, change of C2–C7 Cobb angle of sagittal alignment, adjacent segment instability after the surgery were evaluated.


Taher Yousri Alice Yichientsaia David Thyagarajen James Livingstone Rachel Bradley

Introduction

Over 300,000 patients present with fragility fractures each year. Following a hip fracture, the 30 days mortality is around 8.3 to 9.3%. Mortality increases to 20–24% after the first year and this risk may persist for at least 5 years. The most significant variables that influence mortality are age, gender, fracture type, prefracture residence, prefracture mobility and ASA scores. Common reported postoperative complications responsible for mortality in hip fracture patients include; heart failure, bronchopneumonia and infections. Most of the studies in the literature focus on management variables influencing mortality rather than the encountered postoperative medical problems leading to death.

The aim of this study is to retrospectively analyze the postoperative medical complications which led to death in a cohort of patients, following a hip fracture.

Methodology

This is a retrospective analysis of a cohort of 82, out of 648, patients with hip fractures who died over a period of 2 years (December 2006–January 2009). Forty nine females and 33 males (ratio 1.5:1) were included in the study with a mean age of 87.8 years (range 59–98 years).

For mortality analysis, patients' co-morbidities and medical events leading to death were categorized according to the involved organ system. This included cardiovascular, respiratory, renal, gastrointestinal, neurological and musculoskeletal systems). The timing and decision of DNAR and palliation was noted for each patient.

The 30 days and the overall mortality were the set outcome measures to be reviewed.


Abhinav Gulihar Grahame Taylor Mohammed Hadi

Background

There are several case reports of chondrolysis following joint arthroscopy. Continuous post-operative infusion of local anaesthetic solutions, especially 0.5% Bupivacaine, has been implicated as the causative factor in many of these cases. Recent in vitro studies have shown that even a single exposure of articular cartilage to different local anaesthetic solutions can cause apoptosis and mitochondrial dysfunction in chondrocytes leading to cell death. There is currently no study looking at methods to prevent this toxicity of local anaesthetic solutions to articular cartilage. Glucosamine has a protective and reparative effect on articular cartilage and a Cochrane review in 2007 found that it provides mild benefit in pain and function in patients with arthritis.

Aims

Oncologic: To compare the effect of a single exposure, in vitro, of different local anaesthetic solutions on human articular cartilage.

To investigate the protective and reparative effects of Glucosamine on articular cartilage exposed to 0.5% Bupivacaine.


Raul Torres Guillem Saló Anna Garcia De Frutos Manuel Ramirez Antonio Molina Andreu Llado Maria Teresa Ubierna Enric Caceres

Purpose

compare the radiological results in sagittal balance correction obtained with pedicle subtraction osteotomy (PSO) versus anterior-posterior osteotomy (APO) by double approach in adults.

Material and Methods

between January of 2001 and July of 2009, fifty-eight vertebral osteotomies were carried out in fifty-six patients: 9 Smith-Petersen osteotomy (SPO), one vertebral resection osteotomy (VRO), 30 anterior-posterior osteotomies (APO) and 18 pedicle subtraction osteotomies (PSO), being the lasts two groups the sample studied (48 osteotomies). The mean age of the patients was 56.3 years (17–72). Initial diagnose was: 28 posttraumathic kyphosis, 7 postsurgical kyphosis, 7 adult degenerative disease, 4 ankylosing spondylitis and 2 congenital kyphoscoliosis. We evaluated the preoperative standing radiographs, the postoperative and at final follow-up by digital measurements with iPACS system viewer (© Real Time Image, USA, 2001). The mean follow-up was 54 months (6–98), and complications were analized.


Masako Kaneko Isao Ohnishi Masahiko Bessho Takuya Matsumoto Satoru Ohashi Kenji Tobita Kozo Nakamura

Introduction

Spinal aBMD only explains 50–80% of vertebral strength, and the application of aBMD measurements in isolation cannot accurately identify individuals who are likely to eventually experience bone fracture, due to the low sensitivity of the test. For appropriate treatment intervention, a more sensitive test of bone strength is needed. Such a test should include not only bone mineral density, but also bone quality. Quantitative computed tomography-based finite element methods (QCT/FEM) may allow structural analyses taking these factors into consideration to accurately predict bone strength (PBS). To date, however, basic data have not been reported regarding the prediction of bone strength by QCT/FEM with reference to age in a normal population. The purpose of this study was thus to create a database on PBS in a normal population as a preliminary trial. With these data, parameters that affect PBS were also analyzed.

Methods

Participants in this study comprised individuals who participated in a health checkup program with CT at our hospital in 2009. Participants included 217 men and 120 women (age range, 40–89 years). Exclusion criteria were provided. Scan data of the second lumber vertebra (L2) were isolated and taken from overall CT data for each participant obtained with simultaneous scans of a calibration phantom containing hydroxyapatite rods. A FE model was constructed from the isolated data using Mechanical Finder software. For each of the FE models, A uniaxial compressive load with a uniform distribution and uniform load increment was applied. For each participant, height and weight were measured, BMI was calculated. Simple linear regression analysis was used to estimate correlations between age and PBS as analyzed by QCT/FEM. Changes in PBS with age were also evaluated by grouping participants into 5-year age brackets. One-way analysis of variance was used to compare average PBS for participants in each age range. Mean PBS in the 40–44 year age range was taken as the young adult mean (YAM). The ratio of mean PBS in each age group to YAM was calculated as a percentage. A multivariate statistical technique was used to determine how PBS was affected by age, height, weight, and BMI.


Nicolas Holzer Davide Salvo Anne Karien Marijnissen Aminudin Che Ahmad Emanuele Sera Pierre Hoffmeyer Anne Lübbeke Wolff Mathieu Assal

Introduction

Currently, a validate scale of ankle osteoarthritis (OA) is not available and different classifications have been used, making comparisons between studies difficult. In other joints as the hip and knee, the Kellgren-Lawrence (K&L) scale, chosen as reference by the World Health Organizations is widely used to characterize OA. It consists of a physician based assessment of 3 radiological features: osteophyte formation, joint space narrowing and bone end sclerosis described as follows: grade 0: normal joint; grade 1: minute osteophytes of doubtfull significance; grade 2: definite osteophytes; grade 3: moderate diminution of joint space; grade 4: joint space greatly impaired, subchondral sclerosis. Until now, the K&L scale has never been validated in the ankle. Our objective was to assess the usefulness of the K&L scale for the ankle joint, by determining its reliability and by comparing it to functional scores and to computerized minimal joint space width (minJSW) and sclerosis measurements. Additionally we propose an atlas of standardized radiographs for each of the K&L grades in the ankle.

Methods

73 patients 10 to 20 years post ankle ORIF were examined. Bilateral ankle radiographs were taken. Four physicians independently assessed the K&L grades and evaluated tibial and talar sclerosis on anteroposterior radiographs. Functional outcome was assessed with the AOFAS Hindfoot score. Bone density and minJSW were measured using a previously validated Ankle Image Digital Analysis software (AIDA).


Joshua Yee Anand Pillai Linda Ferris

Introduction

There is a need for a standardised guideline to assist in optimal decision-making in diabetics who have acquired an ankle fracture. Through a critical analysis of the literature, a diagnostic and management algorithm that incorporates a quantitative scoring system is proposed and presented for consideration.

Methods

Publications were identified by conducting a comprehensive keyword search of Medline, EMBASE and CINAHL databases. Search terms included “diabetes,” “ankle,” and “fracture”. Articles published in the English language that were pertinent to the topic were included. Manual search of the references in these relevant papers were also completed to further identify publications for potential inclusion. Publications and conferences not published in the English language or not pertinent to the topic in the above databases were excluded. Duplicate results that occurred in different databases were truncated to a single result.


Peter Vorlat Hugo De Boeck

The reported results of compression fractures are poor. These results are not influenced by the severity of compression, the fracture site or the residual deformity. Otherwise, the factors that determine a patient's recovery are unknown. This study wants to identify the factors determining a patient's recovery after surgical treatment of compression fractures of the thoracolumbar spine. Therefore, in 31 surgically treated patients the pre-injury versus the 12-month follow-up differences in back pain, in global outcome and in participation were prospectively recorded. For this, the visual analogue scale for pain (VAS scale) and the Greenough and Fraser low back outcome scale were used. Of the latter scale, the 3 questions pertaining to participation were combined to create a participation subscale. For these differences and for time lost from work multiple linear regressions with combinations of 16 possible predictors were performed.

At one year patients who smoke report a 25% less favorable global outcome and return 2.8 points (out of 10) less closely to their pre-injury pain level than patients who do not smoke. Patients with a fracture at the thoraco-lumbar junction return 3.3 points less closely to their pre-injury level on the VAS scale than those with a lumbar fracture. For each decrease in 1 of the 3 education levels, the patients stay away from work 15 weeks longer. Per degree of sagittal index at follow-up, patients stay 9 days longer at home. For each increase in level of occupation the return to the pre-injury participation level is 10% less favorable. The variability of time lost from work and of recovery of global outcome, pain and participation level explained by our models is 73%, 37%, 25% and 13% respectively.

Smoking, localization of the fracture at the thoraco-lumbar junction and a high pre-existent level of occupation are strong negative predictors for recovery. A lower education level and sagittal fracture deformity at follow-up are negative predictors for sick leave but might also reflect the concerns of the physician when deciding about return to work.


Gerold Labek Martin Thaler Mark Agreiter Alexandra Williams Mertin Krismer Nikolaus Böhler

Introduction

Austin Moore cervicocephalic prostheses have been a therapeutical option for femoral neck fractures in patients with a reduced general condition for many years. Since treatments other than total hip arthroplasties have also been included in National arthroplasty registers during the last decade, adequate reference data for comparative analyses have recently become available.

Materials and Methods

Based on a standardised methodology, a comprehensive literature analysis of clinical literature and register reports was conducted. On the one hand, the datasets were examined with regard to validity and the occurrence of possible bias factors, on the other hand, the objective was to compile a summary of the data available. The main criterion is the indicator of Revision Rate. The definitions used with respect to revisions and the methodology of calculations are in line with the usual standards of international arthroplasty registers.


Philippe Hernigou Alexandre Poignard Charles Henri Flouzat Lachaniette

Introduction

This study reports the results of percutaneous autologous bone marrow grafting in 62 patients with corticosteroids treatment who had one hip osteonecrosis treated with bone marrow (BM) injection and the other contralateral hip osteonecrosis with core decompression (CD) alone. Only patients with bilateral symptomatic osteonecrosis and with those hips at stage I or II (as defined by Steinberg) were included in this study.

Material and Methods

Between 1988 and 1995, 62 consecutive patients (28 males and 34 females) were included in this study. These patients had a mean age of 31 years (range 18 to 34 years) at the time of the onset of symptoms. The average follow-up was 17 years (range, 15 to 20 years). An average of 152 + 16 milliliters of marrow was aspirated from the iliac crest. The number of stroma progenitor that was transplanted was estimated by counting the Fibroblast Colony Forming Units which express type I and type III collagen. The bone marrow graft obtained after concentration contained average 4889 + 716 progenitors per cubic centimeter (range 3515 to 6293 per cubic centimeter). Each hip received a mean number of thirty cubic centimeters of bone marrow graft (range 27 to 35 cubic centimeters). The average total number of CFU-F injected in each hip was therefore 147 × 103 cells (range 119 × 103 to 195 × 103 cells).


Philippe Hernigou Alexandre Poignard Charles Henri Flouzat Lachaniette Paolo Filippini

Total hip arthroplasty (THA) has been efficacious for treating hip fractures. However, in these patients with fractures a widely variable prevalence of dislocation has been reported, partly because of varying durations of follow-up for this specific end-point. The purpose of the present study was to determine the risk of dislocation as a function of time after total hip arthroplasty in these patients with fractures and to investigate if constrained liners influence the cumulative risk of dislocation.

Between 2000 and 2005, 425 patients with neck fracture underwent primary THA using a constrained acetabular liner (Cemented retentive cup, Groupe lépine, Genay, France). The results of these 425 constrained acetabular liners were compared with 380 THA without constrained liners performed for neck fractures between 1994 and 1999 in the same hospital. All patients were followed for a minimum of 5 years for radiographic evidence of implant failure. The patients were followed at routine intervals and were specifically queried about dislocation. The cumulative risk of dislocation was calculated with use of the Kaplan-Meier method.

Results

For patients without constrained liners, the cumulative risk of a first-time dislocation was 5% at one month and 12% at one year and then rose at a constant rate of approximately 2% every five years to 17% at five years, 19% at ten years, 21% at 15 years for patients who were alive and had not had a revision by that time. For patients with constrained liners, the cumulative risk of a first-time dislocation was 1% at one month, 2% at one year and then did not changed at 5 years and at 10 years for patients who were alive and had not had a revision by that time. Multivariate analysis revealed that the relative risk of dislocation for female patients (as compared with male patients) was 2.1 and that the relative risk for patients who were 80 years old or more (as compared with those who were less than 80 years old) was 1.5. Two underlying diagnoses - cognitively impaired patients or neurologic desease—were also associated with a significantly greater risk of dislocation. At minimum 7 year follow up (range 5 10 yrs), there were 8 radiographic failures (dislocations) of the 425 constrained liners (2%), and no loosenings were noted.

Conclusions

The cumulative long-term risk of dislocation for patients with hip fractures is considerably greater than has been reported in short-term studies. The incidence of dislocation is highest in the first year after arthroplasty and then continues at a relatively constant rate for the life of the arthroplasty. Patients at highest risk are old female patients and those with a diagnosis of neurologic desease. Constrained liners in these patients is an efffective technique to prevent post operative hip dislocation.


J Cazeneuve Jean-François Cazeneuve Yasser Hassan Abdallah Hilaneh

This clinical study analyzes the long-term outcomes and potential complications of the Grammont's reverse prosthesis in case of trauma in elderly population.

Between January 1993 and May 2010, thirty-seven consecutive patients with 26 three- and four-part fractures and 11 fracture-dislocations, mean age 75 (58 to 92) were evaluated with a mean follow-up of 7.3 years.

Eight complications occurred: 2 complex sympathetic dystrophies, 3 dislocations, 2 deep infections and one aseptic loosening of the base-plate leading to 3 re-operations and 2 prosthesis revisions. The mean Constant's score dropped from 55 at two year follow-up to 52 (20 to 84) at last revision because of an augmentation of the pain and a diminution of the strength which represented 67% of the mean score for the injured side. Mean modified Constant's score was 68. Only 58% were satisfied or very satisfied because of poor internal and external rotations avoiding nourishment with utensils, dressing and personal hygiene when the dominant side was involved.

Two complete glenoid borders, fourteen stable inferior spurs, twenty-one inferior scapular notches including ten of them with medial proximal humeral bone loss or radio lucent lines between the bone and the cement were observed. Notches were more important in size when the follow-up was longer. 62% of the patients had worrying images.

The crossing of the clinical and radiological data showed a degradation of the mean Constant's score (41) for pain and strength in cases of notches with troubling proximal humeral images. In spite of only one case of aseptic loosening at 12 year follow-up, results are disappointing and complications and revisions rates important. The functional result is never equal to the pre-broken state. New developments in design, bearing surfaces and surgical technique and a more long term results will refine the role of the reverse concept for fracture.


Petr Nesnidal Jan Stulik Jan Kryl

Purpose of the Study

At our Department, we prefer surgical treatment of all patients with Type II and III fractures of the dens, regardless of the age, with the exception of non-displaced fractures or perfectly reduced fractures in young patients.

Material and Methods

We treated surgically 28 patients 65 years old and older with dens fractures. The group consisted of 13 men and 15 women with a mean age of 77.4 years (range, 65–90 years). According to the type of treatment, anterior srew fixation or posterior C1–C2 fixation, the whole cohort was divided into 2 groups that were subdivided into two age groups of patients 65–74 years old and 75 years old and older. The age group of patients 65–74 years old included 8 patients with a mean age of 68.5 years and the mean age of the age group of patients 75 and more years old was 81 years. The injury was caused in 22 cases by a fall, in 5 by a car accident. Only in 1 case the injury was caused differently. Neurological deficits were found in three patients, all of them Frankel D type. All patients with injury to the dens underwent radiograph examination in the lateral and transoral projections and CT scan including the sagittal and frontal reconstructions of the atlantoaxial complex and in most cases also MRI examination to eliminate injury to the transverse ligament of the atlas. Based on these examinations, the type of injury was determined and method of treatment indicated. Final retrospective evaluation of the patients was carried out at the interval of 12 to 78 months after the primary surgery (mean 31.3 months) taking into account aetiology of the injury, type of injury, neurological finding, method of treatment, union of the dens fracture line or, where appropriate, C1–C2 fusion, stability of the spine and the final outcome. Statistical analysis was based on X2-test.


Hiroshi Fujita Naoyuki Katayama Toshiki Iwase Hiromi Otsuka

Purpose

Exeter stem was introduced to Japanese market at 1996. Since then, owing to its excellent clinical results, the number of the stem used has been increased year by year and more than 2000 stems have been implanted during the year 2009. The present study aims to prove its efficacy for Japanese patients by evaluating short term results of four major dedicated hip centers.

Method

We present the short-term multi-center results of primary THA with Exeter stem combined with modern cementing technique in 881 patients (1000 hips). The average age of the patients at operation was 62.3years (ranging 23 to 89 years). Mean postoperative follow up period was 4.0 (ranging 2 to 9) years.


Andrea Pizzoli Andrea Pizzoli Riccardo Bortolazzi

Aim and Purpose of the study

The authors evaluate the efficacy of athrodiatasis as possible alternative to arthrodesis or arthroplasty in the treatment of ankle arthritis in young patients. They present the long term results (average 19 years) of a small series of patients (10 cases) treated with a monolateral transarticular external fixator associated to different open or athroscopic procedures.

Material and Methodology

The patients have been revaluated with the Kitaoka scoring scale associated to the x-ray evaluation. The authors will compare these results with those reported for the same series at an early evaluation (2,5 y of follow up) and with those published in literature.


Yan Wang Songhua Xiao Yonggang Zhang Xuesong Zhang Zheng Wang Guoquan Zheng

Study Design

Retrospective review.

Objective

To report the technique and results of vertebral column decancellation (VCD) for the management of sharp angular spinal deformity.


Knut Egill Parrington Hansen Lukas Maansson Marianne Olsson

Background

It is unclear which form of anaesthesia is the most favourable in primary total hip replacement (THR) surgery. A recently published systematic review of modern anaesthesia techniques in primary THR surgery (Macfarlane 2009) was not able to show any convincing benefit of regional or general anaesthesia. One retrospective study that examined anaesthesia and leg length (Sathappan 2008), found an increased incidence of leg length difference > 5 mm in those patients who were operated with regional anaesthesia. Our department used a mini invasive approach in supine as standard procedure in THR. The type of anaesthesia that is chosen is up to the individual anaesthetist.

Purpose

We wanted to see if there was any correlation between type of anaesthesia and leg length, total time spent in theatre and recovery room, postoperative hospital stay, blood loss or operating time in primary THR surgery with a mini invasive approach in supine.


Annette W-Dahl Otto Robertsson Stefan Lohmander

Introduction

In contrast to knee arthroplasty, there is no national register on high tibial osteotomy (HTO) in Sweden. The knowledge of the outcome of HTO as a treatment alternative for knee osteoarthritis (OA) is insufficient. The rate of revision to knee arthroplasty after HTO at 10 years has been reported to vary between 8 and 49%. The aim of the study was to evaluate the outcome of HTO performed in Sweden 1998–2007, expressed by rate of revision to knee arthroplasty.

Patienter och Material: 3 196 HTO (69% men) 30 years or older operated on for knee OA in Sweden 1998–2007 were identified through the in- and out-patient care registers from the Swedish National Board of Health and Welfare. Side, left/right, that was operated, diagnosis and indication for surgery were verified through surgical records. Conversions of HTO to knee arthroplasty before 2010 were identified through the Swedish Knee Arthroplasty Register (SKAR). In about 10% of the cases it was unknown what side the HTO had been performed on and thus if the arthroplasty had been on the same knee. In these cases we assumed a worst case scenario of all having been on the same side as the HTO. A 10-year survival analysis was performed using revision to an arthroplasty as the end point.

Result

The mean age was 52 years (range 30- 80) with 97% of the patients younger than 65 years. The cumulative revision rate (CRR) at 10 year was 29.4% (95% CI 27.2–32.9) after adjusting for age and gender. The risk of revision increased by increasing age and the risk of revision after adjusting for age was significantly higher in women than men RR 1.30 (95% CI 1.11–4.54). Most of the HTO's were performed by open wedge osteotomy using external fixation. The risk of revision was higher for closed wedge osteotomies when comparing the closed and open wedge methods RR1.29 (95% CI 1.08–1.55).


Thomas Kappe Christian Fraitzl Heiko Reichel

Background

Femoroacetabular impingement due to a reduced femoral head-neck-offset or excessive acetabular coverage will lead to early cartilage lesions of the hip joint. The purpose of the present study was to analyze the relationship between the extent of bony deformity and the presence and extent of cartilage lesions in femoroacetabular impingement.

Methods

On the radiographs of 92 hip joints in 86 patients with a mean age of 36.5 ± 9.2 years who were operated on for with femoroacetabular impingement by surgical hip dislocation, the acetabular index of the weight-bearing zone, the center-edge-angle, the inclination of the acetabulum, the lateral-head-extrusion-index, retroversion signs of the acetabulum, the neck-shaft-angle, asphericity, superior and anterior alpha angles, and superior and anterior offset and offset ratios were assessed and correlated to the presence and extent of chondromalazia.


Olivier Mares Olivier Mares Sebastien Luneau Vincent Staquet Eric Beltrand Philippe Jean Bousquet Carlos Maynou

Introduction

Acromioclavicular dislocation (ACD) is frequent, at 8% of all shoulder traumas. Management in grade III lesions remains controversial. The present study assessed objective and subjective results at medium-term follow-up (mean, 60 months; range, 12—120 mo) in 27 patients managed by Ligastic® ligament reconstruction for acute dislocation.

Patients and Methods

This is a multicenter, multi-surgeon retrospective study. Between 1998 and 2006, 59 patients were operated on for grade III or IV ACD, in one teaching hospital (Lille, France) and one general hospital (Tourcoing, France). Follow-up was performed by an indepen- dent (non-operator) observer. The 27 acute cases followed up underwent comparative bilateral radioclinical shoulder examination. Initial X-ray assessment found 14 grade-III (52%) and 13 grade-IV (48%) dislocations using Patte's classification.


Peter Wahl Françoise Livio Matthias Jacobi Emanuel Gautier Thierry Buclin

Introduction

Calcium sulphate is a resorbable void filler that can be used for local antibiotic delivery.

Results from clinical studies on chronic osteomyelitis thus treated with local vancomycin have already been published. Despite significant exposure to this drug, there are no pharmacokinetic studies published so far. Based on observations in our patients, a model predicting vancomycin serum and wound fluid levels and toxicity potential is presented.

Methods

Following implantation of Osteoset® added with vancomycin, serum and wound fluid concentrations of this antibiotic have been monitored systematically. The pharmacokinetic analysis was performed using a non-linear mixed-effects model based on a one-compartment model with first-degree absorption.


Sandra Utzschneider Verena Lorber Mirza Dedic Alexander Paulus Birte Sievers Volkmar Jansson

Periprosthetic osteolysis depends on the biological activity of wear particles, but there is little known about the distribution of polyethylene wear particles (PE) in the surrounding joint tissue. The purpose of this study was to examine the localisation of wear particles of six different PEs, including four crosslinked polyethylenes (XPE), as well as their biological activity in the murine knee.

Material and Methods

Wear particles of 4 XPE- and 2 UHMWPE-inserts were isolated (knee joint simulator). For all groups the particles were similar in size and shape (mean diameter 0.3–05μm; 20nm-nucleopore-filter; ISO; n = 100.000).56 female Balb/c mice were randomly assigned to six treatment groups and one control group: control (PBS), XPE1 (3×30 kGy Gamma, annealed/sequential irradiated), XPE2 (95 kGy E-beam, remelted), XPE3 (65 kGy E-beam, remelted), XPE 4 (50 kGy Gamma, remelted), UHMWPE 1, UHMWPE 2. 50 μl of each particle suspension [(0.1% vol/vol (particle volume/PBS volume) after removal of endotoxin] were injected into the left knee joint. After 1 week the mice were killed and a histological and immunhistochemical analysis of the knee joints was done (IL-1, TNF-, ICAM-1). For the immunhistochemistry the articular cartilage, the bone marrow and the synovial membrane were evaluated semiquantitatively (Kruskal-Wallis test; all pairwise multiple comparison procedure; Bonferoni correction; significance level: p<0.05).

Results

All groups showed a thickened synovial layer with an increased cellular infiltration. The particles of XPE 1 and 2 were localised in the bone marrow as well as in the joint space. In contrast, the particles of XPE 3 and 4 were distributed in the synovial layer and in the bone marrow as well, but not in the joint space. The UHMWPE1 particles were mainly located in the bone marrow and joint space while the UHMWPE2 particles were mainly found in the bone marrow and the synovial layer. For all PE groups there was a higher cytokine expression compaired to control (p<0.0024) without any differences between the groups (bone marrow/synovial layer). The chondrocytes in the groups with XPE 1- and XPE 2-particles expressed more TNF- than in the control group and the other treatment groups (p = 0.000).


Livio Quagliarella N Sasanelli G Belgiovine V Castaldo

Introduction

Lesions of the upper extremities, and especially of the hands, are the most common form of occupational injury in the agricultural and industrial sectors [1]. When the grip strength and the way of its development are relevant, it would be very useful to be able to rely on an instrumental procedure, in support of the clinical examination, for both clinical and legal purposes.

The possibility of differentiating between healthy subjects and patients affected by disabilities of the upper extremities, using parameters based on force-time curves for handgrip tests, was investigated with the aim to obtain objective and comprehensive outcome, useful to support the clinical evaluation.

Materials and Methods

The reference group consisted of 151 subjects examined for occupational trauma of the upper limbs, all with a dominant right arm, who had suffered an occupational injury. The 74% of the injuries affected the hand. A further 648 healthy people were enrolled as the control group.

Grip strength was measured with an electronic dynamometer. The signals acquired with the dynamometer were subdivided into 5 characteristic phases [2]: first reaction, explosive contraction, isometric contraction, release and relaxation.

The maximum force, the ratio between the maximum force exerted by the two arms and an index related to the explosive muscle power and the ability to maintain maximum voluntary contraction were calculated.

Percentage variations of each parameter, as compared to a threshold value, were taken into account and an overall value (T) was calculated, representing the sum of these variations.


Guenoun Benjamin Frédéric Zadegan Dider Hannouche Rémy Nizard

Limb length disparity is a frequent complication after hip surgery inducing many surgeon-patients conflicts. To date no study has been able to precisely quantify such limb length disparity. EOS® system, currently validated to measure lower limb parameters, allows from two bi-dimensional numerical orthogonal radiographies in standing position to obtain a tri-dimensional reconstruction of lower limbs. A computerized system achieves the parameters calculation.

The aim of this study is to precisely measure the limb length disparities and the other hip parameters following total hip arthroplasty surgical procedure, by using a standard X-rays and using EOS® three-dimensional reconstructions.

Twenty-eight patients programmed for total hip arthroplasty have been included (i.e. thirty lower limbs). Two independent performers have carried out twice the measures either on standard X-rays and using three-dimensional reconstructions of the lower limb disparities prior and after the surgical procedure.

The inter and intra-observer reproducibility for the measure of the lower limb disparities have been of the EOS® measures have been respectively of 0.854 and 0.865 and for the standard X-rays of 0.717 and 0.726.

Mean length disparity observed was before Total Hip Arthroplasty of −0.328 cm (0.705; −1.266/0.530) and was of 0.088 mm (1.326; −1.635/0.632) after. We are able to decrease the lower limbs disparity in 69.1% and for the average of 0,416cm.

Using EOS® system has allowed assessing with greater precision the possibility to restore equal lower limb length.

This assessment has permitted introducing a new planning procedure including EOS® imaging associated to the fusion of the prosthetic tri-dimensional image in order to achieve adequate lower limb length.


Dmitry Popkov Pierre Lascombes Arnold Popkov Pierre Journeau Thierry Haumont

Introduction

Since 2001 we use the flexible intramedullary nailing (FIN) in bone lengthening in children. This study estimates results of EF+FIN association considering the duration of external fixation and complications.

Materials and Methods

Since 2001 we performed 294 bone lengthenings (338 segments of UL and LL) in 250 children 3 to 16 years old (11.01±0.23 in average). The length discrepancy was congenital in 163 cases, the sequelae of trauma or osteomyelitis were observed in 87 patients. In group I (195 cases) the Ilizarov fixator alone was applied, in group II the Ilizarov fixator (91 cases) or TSF® (8cases) were combined with FIN.

The healing index was compared between the groups of the same etiology with similar type of distraction osteosynthesis.

The date of consolidation corresponded to the day of removal of the external fixator, while intramedullary nails remained in place thus protecting the bone. Healing index was calculated by relating the duration of wearing of the external fixator (in days) and the amount of lengthening (in cm).


Christian Schröder Sandra Utzschneider Thomas Grupp Bernhard Fritz Volkmar Jansson

Introduction

Minimally invasive implanted unicompartmental knee arthroplasty (UKA) leads to excellent functional results. Due to the reduced intraoperative visibility it is difficult to remove extruded bone cement particles, as well as bone particles generated through the sawing. These loose third body particles are frequently found in minimally invasive implanted UKA.

The aim of this study was to analyse the influence of bone and cement particles on the wear rate of unicompartmental knee prostheses in vitro.

Material & Methods

Fixed- bearing unicompartmental knee prostheses (n = 3; Univation F®, Aesculap, Tuttlingen) were tested with a customized four-station servo-hydraulic knee wear simulator (EndoLab GmbH, Thansau, Germany) reproducing exactly the walking cycle as specified in ISO 14243-1:2002. After 5.0 million cycles crushed cortical bone chips were added to the test fluid for 1.5 million cycles to simulate bone particles, followed by 1.5 million cycles blended with PMMA- particles (concentration of the third-body particles: 5g/l; particle diameter: 0.5- 0.7 mm). Every 500 000 cycles the volumetric wear rate was measured (ISO 14243-2) and the knee kinematics were recorded.

For the interpretation of the test results we considered four different phases: breaking in- (during the first 2.0 million cycles), the steady state- (from 2.0 million to 5 million cycles), bone particle- and cement particle phase.

Finally, a statistical analysis was carried out to verify the normal distribution (Kolmogorov-Smirnov test), followed by direct comparisons to differentiate the volumetric wear amount between the gliding surfaces (paired Student's t-test, p<0.05).


Nils Hailer Stergios Lazarinis Per Mattsson Jan Milbrink Hans Mallmin

Introduction

Several short femoral stems have been introduced in primary total hip arthroplasty, supposedly in order to save proximal bone stock. We intended to analyse primary stability, changes in periprosthetic bone mineral density (BMD), and clinical outcome after insertion of the uncemented collum femoris preserving (CFP)-femoral device.

Methods

A prospective cohort study on 30 patients scheduled for receiving the CFP-stem combined with an uncemented cup was carried out. Stem migration was analysed by radiostereometry (RSA). Preoperative total hip BMD and postoperative periprosthetic BMD in Gruen zones 1–7 was investigated by DXA, and the Harris hips score (HHS) was determined. The patients were followed up to 12 months.


Lukas Negrin Vilmos Vécsei

Objective

To provide a best estimate of the average treatment effect when microfracture was chosen as the intervention of choice in patients with full-thickness cartilage defects of the knee.

Design

We focussed on controlled studies which either referred to microfracture alone or in comparison with any other surgical treatment of articular cartilage of the knee. Papers including patients who had been treated by microfracture and concomitant adjuvant procedures like ACL reconstruction or meniscus repair were accepted too, whereas papers reporting on the microfracture technique combined with the implantation of a scaffold were excluded. To achieve a best estimate of the average, to be expected treatment effect we pooled pooled before–after data of study arms using microfracture. Because cartilage studies employ various scales to measure functional improvements, we standardized treatment effects using Hedges' g. To provide clinically meaningful estimates we converted the pooled summary effect back into the respective scales by multiplying the pooled effect with pooled standard deviations of each included clinical scale.


Dominique Knight Cristina Alves John Wedge

Background

Habitual hip subluxation and dislocation is a potentially disabling feature of Trisomy 21. We describe long-term outcomes following precise use of the femoral varus derotation osteotomy to achieve and maintain hip stability and community ambulation.

Methods

All individuals with Trisomy 21, who had hip surgery at Toronto's Hospital for Sick Children between 1998 and 2008, were searched using the hospital databases.

16 hips in 9 children aged less than 10 years, were identified. All had a femoral varus derotation osteotomy (VDRO) with a target femoral neck shaft angle (NSA) of 105° and less than 20° external rotation. All were performed by the senior author JHW. The clinical notes and radiographs were reviewed from presentation to final follow up.

Continuous variables were assessed for normality with the d'Agostino Pearson test. Normally distributed variables are presented as means with 95% confidence intervals. Pre and postoperative means were compared using the student's t-test for paired samples.


Matthew Seah CMichael Robinson

Background

Proximal humeral fractures are common and a minority develop non-union, which can result in pain and disability. We aimed to identify the risk factors and quantify the prevalence of non-union.

Methods

A thirteen-year retrospective study of 7039 patients with proximal humeral fractures was performed and a database created. 246 patients with non-union were compared to a control group to identify risk factors. Logistic regression analyses were performed to identify significant variables obtained at presentation to predict non-union.


Paul Ackermann Nicos Schizas Daniel Bring Jian Li Therese Andersson Anna Fahlgren Per Aspenberg

Introduction

Traumatized musculoskeletal tissue often exhibits prolonged time to healing, mostly due to low blood flow and innervation. Intermittent Pneumatic Compression (IPC) increases blood flow and decreases thromboembolic event after orthopedic surgery,[1] however little is known about healing effects.[2] We hypothesized that IPC could stimulate tissue repair: 1.) blood flow 2.) nerve ingrowth 3.) tissue proliferation and during immobilisation enhance 4.) biomechanical tissue properties.

Methods

Study 1: In 104 male Sprague Dawley (SD) rats the right Achilles tendon was ruptured and the animals freely mobilized. Half the group received daily IPC-treatment, using a pump and cuff over the hindpaw that inflates/deflates cyclicly, 0–55mmHg (Biopress SystemTM, Flexcell Int.), and the other half received sham-treatment. Healing was assessed at 1,3,6 weeks by perfusion-analysis with laser doppler scanner (Perimed, Sweden), histology and biomechanical testing.

Study 2: 48 male SD-rats were ruptured as above. Three groups of each 16 rats were either mobilized, immobilized or immobilized with IPC treatment. Immobilization was performed by plaster cast. Healing was assessed at 2 weeks with histology and biomechanical testing.


Daniël Haverkamp Matthijs Somford Mark Klinkenbijl Harm Vis Van Der Rob Albers

Background

A lot of discussion persists whether obesity negatively influences the outcome of hip arthroplasty. Current literature does not answer this question, since manuscripts showing a worse outcome and those showing a similar outcome can both be found. We performed a meta-analysis with the primary research question whether obesity has a negative influence on short and long term outcome of total hip arthroplasty.

Methods

A search of the literature was performed and studies comparing the outcome of hip arthroplasty in different weight groups were included. Methodology of the included studies was scored according to the Cochrane guidelines. Data extraction and pooling of the data was performed. For continuous data a weighted mean difference and for dichotomous variables a weighted Odds ratio was calculated. Heterogeneity was calculated using I2 statistics.


Peter Verdonk Tineke De Coninck Wouter Huysse René Verdonk

Purpose

to evaluate the radial displacement of meniscal allograft transplants (MATs) in patients operated with an open technique vs. an arthroscopic technique at 1 year postoperatively. Radial displacement or extrusion of the graft is frequently observed after meniscus transplantation. The hypothesis is that arthroscopically inserted MATs extrude less than open MATs and therefore have a more intra-articular position than open surgery transplants.

Materials and Methods

39 patients were included in the study: the first group of open surgery transplants consisted of 16 patients (10 lateral, 6 medial). The second group of arthroscopic transplants consisted of 21 patients (14 lateral, 7 medial). MR-images were taken one year post-surgery. The displacement, evaluated on 1,5T MR coronal images, was defined as the distance between the tibial plateau and the outer edge of the meniscus.


Peter Verdonk Pieter Beekman Tineke De Coninck René Verdonk Frank Raat

Purpose

to evaluate the kinematics of a knee with a polyurethane meniscal scaffold for partial meniscus defect substitution during flexion under weightbearing conditions in an upright MRI. In addition, radial displacement and the surface of the scaffold was compared to the normal meniscus.

Materials and Methods

One cadaver with a normal lateral meniscus and medial scaffold in the left knee and with a normal medial meniscus and lateral scaffold in the right knee. The scaffolds were implanted to substitute a 3 cm meniscus defect in the posterior horn. The cadaver was scanned in an 0,7T open MRI with a range of motion from 0-30-60-90 to hyperflexion. Kinematics were evaluated on sagittal images by the following two parameters: the position of the femoral condyle, identified by the centre of its posterior circular surface, which is named the flexion facet centre (FFC), and the point of closest approximation between the femoral and tibial subchondral plates, the contact point (CP). Both were identified in relation to the posterior tibial cortex.

The displacement, measured on coronal images, is defined as the distance between the tibial plateau and the outer edge of the meniscus. The surface was also measured on coronal slices and contains the triangular surface of the meniscus.


Jaap Van Der Maas Peter Verdonk Thomas Tampere Fredrik Almqvist René Verdonk

Background

There is growing evidence in literature that meniscal allograft transplantation performed with the right indications results in significant pain relief and functional improvement of the involved joint. Long-term data on clinical and radiological outcome are however scarce.

Methods

We evaluated 89 transplants (53 lateral and 36 medial) in 87 patients. Mean time of follow-up was 15,5 ± 2,85 years (range 9,9–20,4), mean age at surgery was 35,2 years (range 22–50). Clinically, the patients were evaluated using a KOOS, SF-36, HSS, VAS, Tegner and Lysholm score. HSS scores were compared to pre-operative and mid-term follow-up data. Each patient received radiographs (AP, profile and Rosenberg view). Radiological outcome parameters were joint space width narrowing and Fairbank changes and were scored according to IKDC. Failures were defined as patients who were converted to an arthroplasty.


Jeannette Penny J Varmarken O Ovesen C Nielsen S Overgaard

Introduction

Metal on metal articulations produce chromium (Cr) and cobalt (Co) debris, particularly when the articulations are worn in. High levels in the peripheral blood are indicative of excess wear and may cause adverse effects. The present RCT investigates metal ion levels and the relationship of Co, Cr ions and lymphocyte counts during the running-in period.

Materials and Methods

Following randomization to RHA (ASRTM, DePuy) or THA we obtained whole blood (wb), and serum (s) samples at baseline, 8 w, 6 m and 1 y. We measured the Co and Cr concentrations, the total lymphocyte count as well as the CD3+, CD4+, CD8+, CD19+ and CD16+/CD56+ sub populations. Cup inclination and anteversion angles came from conventional radiographs. Activity was measured as steps by pedometer and UCLA activity. Data are presented as median (range).


Jennifer Nichols Nicholas Ferran Jennifer Nichols Radhakant Pandey Amit Modi Grahame Taylor Alison Armstrong

We report a retrospective review of outcome after shoulder hemiarthroplasty for proximal humerus fractures. All patients managed with shoulder hemiarthroplasty for proximal humerus fractures between 1997 and 2008 were included. Clinical notes were reviewed and surviving patients completed postal Oxford Shoulder Score (OSS) questionnaires. Results were analysed to assess whether there was a difference in outcome for those above the age of 70 years. A total of 96 patients were treated during this period. Female to male ratio was 3.36:1 with mean age 72 ± 9.6 (45–93) years at time of fracture. At time of review 30.2% of patients were dead. Two patients were lost to follow-up after discharge. Complete case notes were available in 68 patients. Response rate to the OSS was 67.2%. There were 20 patients below 70 years and 48 patients above 70 years of age. The ASA grade was II in 60% of patients. Mean follow-up was 52 months. There were 2 in hospital post-operative deaths due to medical complications. Mean OSS was 27 (3–47) of a maximum of 48, with no significant difference between groups. Overall complication rate was 27.9%, with no significant difference between groups. Ten year survival was 96.9% overall with no significant difference between groups. There appears to be no significant difference in functional outcome, complication rate, or implant survival between patients below or above the age of 70 years treated with primary hemiarthroplasty for fracture of the proximal humerus. This procedure however carries a high complication rate in this group of patients.


Graham Chuter Jayasree Ramaskandhan Taha Soomro Malik Siddique

Background

The recommended indications for total ankle replacement (TAR) are limited, leaving fusion as the only definitive alternative. As longer-term clinical results become more promising, should we be broadening our indications for TAR?

Materials and Methods

Our single-centre series has 133 Mobility TARs with 3–48 months' follow-up. 16 patients were excluded who were part of a separate RCT. The series was divided into two groups. ‘Ideal’ patients had all of the following criteria: age >60y, BMI <30, varus/valgus talar tilt <10°, not diabetic, not Charcot, not post-traumatic. The ‘Not ideal’ group contained those who did not fit any single criteria. We compared complications and outcome scores between both groups.


Stig Brorson Lars Henrik Frich Annika Winther Asbjorn Hrobjartsson

Introduction

There is considerable uncertainty about the optimal treatment of displaced four-part fractures of the proximal humerus. Within the last decade locking plate technology has been considered a breakthrough in the treatment of these complex injuries.

Methods

We systematically identified and reviewed clinical studies of the benefits and harms after osteosynthesis with locking plates in displaced four-part fractures.


Graham Chuter Malik Siddique

Background

Total ankle replacement (TAR) is increasingly offered as an alternative to ankle fusion for the management of severe ankle arthritis. As with all other types of joint arthroplasty, there are risks involved and complications that occur; these increase with case complexity. We present the complications and management from a single-centre series.

Results

Since 2006, we have performed 150 Mobility TARs with up to 4 years' follow-up. We have excluded 16 that are part of a separate RCT and 10 with less than 3 months' follow-up. 124 TARs were included in our study (117 patients). Three ankles (2.4%) had superficial wound infections treated successfully with antibiotics. One ankle (0.8%) required an arthroscopic washout and débridement but the implant was retained. 11 ankles (8.9%) had a periprosthetic fracture: One was intra-operative; 10 were post-operative (2 fixed). Four patients (3.2%) developed CRPS. One ankle required fusion surgery (following subsidence of the talar component) with another one pending revision (ligament instability causing implant displacement). No patient had a symptomatic deep vein thrombosis or thromboembolic event.


Julian Maempel Melanie Coathup Neville Calleja Frederick Zammit Maempel Tim Briggs Stephen Cannon Gordon Blunn

Background/Aims

The development of extendable prostheses has permitted limb salvage surgery in paediatric patients with bone tumours in proximity to the physis. Prostheses are extended to offset limb length discrepancy as the child grows. Aseptic loosening (AL) is a recognised complication. The implant stem must fit the narrow paediatric medullary canal and remain fixed while withstanding growth and increasing physical demands. Novel designs incorporate a hydroxyapatite (HA) coated collar that manufacturers claim improves bony ongrowth and stability, providing even stress distribution in stem and shoulder regions and providing a bone-implant seal, resulting in decreased AL and prolonged survival. This study aims to assess whether there is a relationship between bony ongrowth onto a HA collar and AL. Hypothesis: Bone ongrowth onto the HA collar of extendable prostheses is associated with more stable fixation and less AL despite patient growth.

Methods

Retrospective review of 51 primary partial femoral extendable prostheses implanted over 12 years from 1994–2006 (followed up to death at a mean of 2.5±2.2 years or last clinical encounter at a mean of 8.6 years) and 24 subsequent revisions, to ascertain failure rate and mode, together with a cohort study reviewing bony ongrowth onto the HA coated collar in 10 loose and 13 well fixed partial femoral, humeral and tibial implants. Patient growth was measured as a change in bone:implant-width ratio.


Graham Chuter Jayasree Ramaskandhan Malik Siddique

Introduction

The standard practice of uncomplicated total ankle replacement (TAR) involves post-operative immobilisation. Periprosthetic fracture is a well-recognised complication following ankle arthroplasty. It occurs predominantly as a stress reaction on the medial tibial metaphysis during the post-operative rehabilitation period. Occasionally it occurs during surgery. We present fractures from a single-centre series of Mobility TARs.

Materials and Methods

We have 133 TARs with 3 to 48 months' follow-up. 28 patients were excluded for the following reasons: other major procedure performed concurrently (osteotomy or tendon transfer), custom prosthesis, revision surgery, fusion conversions, or patients involved in a separate RCT (n = 16). We do not routinely immobilise patients post-operatively but allow partial to full weight-bearing as able. Outcome scores were compared to those without fractures.


Julian Maempel Melanie Coathup Neville Calleja Stephen Cannon Tim Briggs Gordon Blunn

Background

Extendable proximal femoral replacements(PFR) are used in children with bone tumours in proximity to the proximal femoral physis, previously treated by hip disarticulation. Long-axis growth is preserved, allowing limb salvage. Since 1986, survival outcomes after limb salvage and amputation have been known to be equal.

Method

Retrospective review of all patients <16years undergoing extendable PFR at Royal National Orthopaedic Hospital (UK) between 04/1996 and 01/2006, recording complications, failures, procedures undertaken and patient outcomes.


Nima Heidari Surjit Lidder Wolfgang Grechenig Annelie Weinberg Norbert Tesch Axel Gänsslen

Introduction

Application of an external fixator for type B and C pelvic fractures can be life saving. Anteriorly the fixator half pins can be placed in the long and thick corridor of bone in the supra-acetabular region often referred to as the low anterior ex-fix. Pins in this location are favoured as they are more stable biomechanically. The bone tunnel for the low anterior ex-fix can be visualised with an iliac oblique projection intra-operatively. In some cases despite being outside the articular surface it may still be low enough to pass through the capsular attachment of the hip joint on the anterior inferior iliac spine. We aim to provide radiological markers for the most superior fibres of the capsule to help accurate extra-capsular pin placement within the supra-acetabular bone tunnel.

Materials and Methods

Thirteen cadaveric pelves, embalmed with the method of Thiel, were used for this study. An image intensifier was positioned to acquire an iliac oblique outlet view, such that the supra acetabular bone tunnel was visualised. This was achieved by positioning the beam 30 degrees cephalad and 20 degrees medial. Both left and right hemipelves were examined in this way. A standard size metallic disc was included in all images with in the acetabulum to allow for image calibration. The proximal most fibres of the hip joint capsule were marked with a K-wire so that their relation to the bone tunnel could be clearly seen on the images.

Once all images were acquired they were calibrated and analysed using ImageJ Software to estimate the height and maximum width of the bone tunnel as seen on the images and the vertical distance of the superior most fibres of the capsule from the dome of the acetabulum.


Mateen Arastu Abbas Rashid Syed Haque Stephen Bendall

Introduction

The rising incidence of metastatic bone disease (MBD) in the UK poses a significant management problem. Poorly defined levels of service provision have meant that improvements in patient prognosis have been mediocre at best. For that reason the British Orthopaedic Association (BOA) in conjunction with the British Orthopaedic Oncology Society (BOOS) issued guidelines in 2002 on good practice in the management of MBD. Despite the availability of these standards, there is very little robust data available for audit. The aim of this study was to conduct a regional survey of how these guidelines are being used in the management of MBD.

Methods

A questionnaire was designed with 9 multiple choice questions representing the most common MBD scenarios. This was posted to 106 Consultant Orthopaedic Surgeons in 12 NHS Trusts in the South East of England.


Annelie Weinberg Eva Widni Karin Pichler Max Seles M Manninger Nima Heidari

Injuries to growth plates may initiate the formation of reversible or irreversible bone-bridges, which may lead to partial or full closure of the growth plate resulting in bone length discrepancy, axis deviation or joint deformity. Blood vessels and vascular invasion are essential for the formation of new bone tissue. The aim of our study was to investigate the spatial and temporal expression VEGF and its receptors R1 and R2 as well as the ingrowth of vessels in the formation of bone bridges in a rat physeal injury model. Quantitative Real Time - Polymerase Chain Reaction (qRT-PCR) was performed for Vascular Endothelial Growth Factor (VEGF) and its R1 and R2 receptors. Samples from the proximal epiphysis, physis and metaphysis of the tibial bone were prepared for immunohistochemical analysis to demonstrate the spatial expression of VEGF and its R1 and R2 receptors as well as laminin. Kinetic expression of VEGF and VEGF-R1 mRNA documented a tendency towards an expression increase on day 7. Histological analysis showed a haematoma containing bone fragments on day 1which was replaced by a bony bridge by day 14. This remodelled and consolidated by day 82. These trabeculae were accompanied by vessel formation. Expression of VEGF was observed on the bone fragments and the haematoma from day 1 through to day 82. Although VEGF-R1 was expressed at all time points the expression of VEGF-R2 was noted until the 14th day. Physeal bone bridge formation is a combination of both enchondral and intramembranous ossification. This is in part triggered by the bony debris observed within the lesion in the first few days. By washing this debris out the likelihood of bone bridge formation may be reduced. We recommend this practice when operating on the physis in order to avoid iatrogenic physeal bar formation.


José Fraga Ferreira Rui Cerqueira Sofia Viçoso Tiago Barbosa João Oliveira Paulo Vasconcelos

Slipped capital femoral epiphysiolysis (SCFE) is a rare condition with a unknown aetiopathogenesis. An early diagnosis and treatment is essential to minimize premature degeneration of the joint. The authors reviewed the cases treated between 1980 and 2005 in our institution. This study was aimed at evaluating patients with hip epiphysiolysis surgically treated by canullated screws or pinning and previously controlled by short-term follow-up, in order to evaluate radiographic medium/ long term evolution, looking for evidence of degenerative arthritis or femoroacetabular impingement.

We performed a retrospective review of the clinical notes and radiographs of all patients with slipped upper femoral epiphysis who were surgically treated at our institution between January 1980 and December 2005. These patients performed radiographs to detect evidence of osteonecrosis, chondrolysis, degenerative arthritis or femoroacetabular impingment. To grade the radiological osteoarthritic changes the grading system of Kellgren and Lawrence was used. These changes were correlated with the existence of femoroacetabular impingement. The radiological results were correlated with the Loder'sclassification of stability and the morphological classification.

43 patients were reviewed, corresponding to 47 treated hips. AP and Lowenstein x-ray views were taken in all patients. The alfa angle and the head-shaft angle were measured in the Lowenstein view (frog-leg).

Of 16 patients with impingement only 1 patient didn't present pistol grip deformity. 4 contralateral hips also presented the deformity. The mean alfa angle was 99,4.

43% of the patients with unstable hips have impingment. In stable hips this percentage is of 35%.

The Patrick test was positive in 30% of the hips with SCFE and only 17% of the unafected hips. The Kellgren and Lawrence scale was very diferent between trhe SCFE and control groups, with 43% grade 2, 17% grade 3 and 6% grade 4, versus 30% grade 2, 6% grade 3 and 0% grade 4.

Some patients show bilateral pistol grip deformity and clinical signs of impingment, despite only having one hip with SCFE


Jingming Xie Yingsong Wang Zhendong Yang Ying Zhang

Introduction

To introduce a new classification method and analyze related risk factor about lateral wall perforation associated with lower cervical pedicle screw and free-hand insertion technique.

Methods

A Retrospective study was made to analyze 214 patients (1024 screws) with various cervical spine disorders, involved in pedicle screw instrumentation at C3-7 from July 2004 to July 2009. Researchers assessed the position of the screws in the pedicle by carefully probing intraoperatively and studying postoperative thin-slice computed tomography scan. Perforation of lateral wall was classified into two phases. Phase I refers to the burst of the pedicle by screw, which means that the length of screw threads penetrating the external cortex of pedicles on CT scan is 2 mm, whereas in Phase, the length is >2 mm. The Penetrated screws and related factors were analyzed though Backward Stepwise (Wald) Logistic regression.


Megan Hadley Fiona Hadfield Cath Hardaker Graham Isaac John Fisher John Wye James Barnett

Introduction

Hip wear simulation is a widely used technique for the pre-clinical evaluation of new bearing designs. However, wear rates seen in vitro can often be significantly different to those seen clinically. This can be attributed to the difference between the optimal conditions in a simulator and wide ranging conditions in real patients.

This study aimed to develop more clinically relevant simulator tests, looking specifically at the effects of cup inclination angle (in vivo) and stop-dwell-start (SDS) protocols on a clinically available product.

Method

Five tests using a Paul type walking cycle (ISO 14242) were carried out on two ProSim hip simulators:

28mm MoM, standard walking, cup inclination 45°, (n = 5)

36mm MoM, standard walking, cup 45°, (n = 4)

36mm MOM, SDS: 10 walking cycles and pause of 5s with stance load of 1250N cup 45°, (n = 5)

36mm MOM, SDS: 10 walking cycles and pause of 30s with stance load of 1250N, (n = 5) cup 45°

36mm MOM, standard walking, cup 55°(n = 5), and 65°(n = 5).

All samples had matched clearances, measured using a CMM (Prismo Navigator, Zeiss, Germany). Wear was measured gravimetrically (Sartorius ME235S: 0.01mg).


Régis Pailhé Nicolas Reina Jean Michel Laffosse Jean Louis Tricoire Philippe Chiron Jean Puget

Background

Floating shoulder (FS) is, according to Goss et al, a double disruption of the superior shoulder suspensory complex which usually results from a glenoid neck fracture and a ipsilateral midclavicular fracture. However, the interruption can interest the whole scapular belt from acromion to sterno-clavicular joint. It occurs mostly after a violent traumatism with direct lateral impact on the shoulder. That leads to complex therapeutic issues with sometimes uncertain results.

Material

Between 1984 and 2009, 35 patients (30 men, 5 women), mean age 35 years [16–72] with FS, were treated in our department. Most of them sustained road accident (31cases) with polytraumatism context in 12 cases. A CT scan was realized in the majority of cases to specify the scapular fracture and look for intra-thoracic immediate complications. Mostly, glenoid neck fracture associated with a clavicular fracture has been found out (15cases). Orthopaedic treatment has been realized in 18 cases. Surgical management has been decided for open reduction of sterno-clavicular joint in 2 cases, isolated fixation of the clavicle in 9 cases, of the scapula in 3 cases, and of both scapula and clavicle in 3 cases. Criteria for clinical evaluation were an algo-functional scale (Oxford Shoulder Score, OSS), a subjective Constant Shoulder Score, a functional incapacity scale (Shoulder Simple Test, SST), scales of life quality (DASH and SF12) and global indications (Single Assessment Numeric Evaluation, SANE).


Kristoff Corten Steven Walscharts Jos Vander Sloten Ward Bartels Jean-Pierre Simon

Introduction

It was the purpose to evaluate the biomechanical changes that occur after optimal and non-optimal component placement of a hip resurfacing (SRA) by using a subject specific musculoskeletal model based on CT-scan data.

Materials and Methods

Nineteen hips from 11 cadavers were resurfaced with a BHR using a femoral navigation system. CT images were acquired before and after surgery. Grey-value segmentation in Mimics produced contours representing the bone geometry and identifying the outlines of the 3 parts of the gluteus medius. The anatomical changes induced by the procedure were characterised by the translation of the hip joint center (HJCR) with respect to the pelvic and femoral bone.

The contact forces during normal gait with ‘optimal’ component placement were calculated for a cement mantle of 3 mm, a socket inclination of 45° and anteversion of 15°. The biomechanical effect of ‘non-optimal placement’ was simulated by varying the positioning of the components.


Jonathan Perera Dylan Griffiths Panagiotis Gikas Jonathan Perera James Donaldson William Aston Robin Pollock John Skinner Stephen Cannon Timothy Briggs

Sixty eight consecutive patients underwent proximal humeral replacement with a fixed fulcrum massive endoprosthesis, for tumour, between 1997 and 2007. The mean age was 46 years, (7–87). Ten patients were lost to follow up and 16 patients died. The 42 surviving patients were assessed using the Musculoskeletal Tumour Society (MSTS) Score and the Toronto Extremity Salvage Score (TESS). The mean MSTS score was 72.3% and the mean TESS was 77.2%.

Four of 42 patients received a new constrained humeral liner to reduce the risk of dislocation. This sub group of 4 patients had a mean MSTS score of 77.7% and a mean TESS of 80.0%.

Endoprosthetic replacement for tumour of the proximal humerus using this prosthesis is a reliable operation yielding good functional results without the documented problems of unconstrained prostheses. The performance of this prosthesis is expected to improve further with the new constrained humeral liner.


Dante Dallari Nicolandrea Del Piccolo Lucia Savarino Rossana Fantasia Nicola Rani Cesare Stagni

Introduction

We evaluated the osteogenic potential of a novel biomimetic bone paste (DBSint®), made of a combination of a human demineralized bone matrix (hDBM) and a nano-structured magnesium-enriched hydroxyapatite (Mg-HA), in a standardized clinical model of high tibial osteotomy for genu varus.

Methods

A prospective, randomized, controlled study was performed and thirty patients were enrolled and assigned to three groups: DBSint® (Group I), nano-structured Mg-HA (SINTlife®) (Group II) and lyophilized-bone-chips (Group III). Six weeks after surgery, computed tomography-guided biopsies of the grafts were performed. Clinical/radiographic evaluation was performed at six weeks, twelve weeks, six months, one and 2 year after surgery, in order to verify if the graft type influenced the healing rate.


Alanna Pentlow James Heal

Total hip replacements have been shown to give superior outcomes in patients with intracapsular fractures of the neck of femur compared with hemiarthroplasty. Collarless uncemented femoral stems give excellent long term results in elective hip replacements but there are few studies looking at their outcomes in fractured neck of femur patients. There is some concern that in trauma patients bone quality maybe inferior as most neck of femur fractures are secondary to osteoporosis. The presence of osteoporosis and subsequent widened femoral canal may compromise the mechanical stability of uncemented femoral stems and result in early subsidence, which can lead to altered leg length and decreased hip stability. The aim of this study was to assess whether early subsidence occurred when collarless uncemented stems were used to treat patients with fractures of the neck of femur.

Post-operative radiographs of 33 patients, mean age 71, who underwent an uncemented collarless total hip replacement for a fracture, were reviewed. The distance from the calcar to the tip of the prosthesis was measured for each patient on the initial post operative radiograph and again on the follow-up radiograph at 6 months post operation. Any subsidence was recorded and magnification for each radiograph was calculated by measuring the diameter of the femoral head, which was known to be 36mm. Distances were then adjusted for magnification. The same procedure was performed on 36 age-matched patients, mean age 71, who underwent elective uncemented total hip replacements for osteoarthritis. Hospital notes for each patient were reviewed to assess for complications and DEXA scan results for trauma patients were also evaluated where available.

The mean femoral stem subsidence was significantly greater in the fracture cohort than in elective patients (p = 0.001) with mean subsidence of 4.07mm (range 0.02–18.5mm) and 1.57mm (range 0–5.5mm) respectively. In the fracture cohort there were 3 revisions within 6 months of surgery, 1 for infection and 2 for femoral stem subsidence leading to dislocation. There were no revisions in the elective cohort. DEXA scan results were available for 21 of the 33 fracture cohort patients. All these patients had abnormal bone density with 52% being osteoporotic and 48% osteopenic.

This study showed that collarless uncemented stems subsided significantly when performed for fractures and had a high early revision rate. We therefore recommend that cemented or collared femoral stems be used in patients with femoral neck fractures requiring total hip replacement to reduce the risk of femoral stem subsidence.


Sven Dietz Thomas Schwarz Werner Sternstein Pol Rommens

Open reduction and internal fixation of proximal humerus fractures with angular stable plates is, beside antegrade nailing of the humerus, a standard procedure. A retrograde nail has been developed to avoid penetrating the rotator cuff and to avoid opening the fracture side during osteosynthesis.

The aim of our biomechanical study was to evaluate if retrograde nailing of proximal humerus fractures is as stable as locking plate osteosynthesis.

The biomechanical properties of 2 implants were tested in 11 human fresh frozen cadaveric humeri pairs. The Retron Nail® and the Philos® plate were implanted after osteotomy. All specimens were suspected to axial and torque load for 1000 cycles in a servo pneumatic testing apparatus.

The Philos® plate had greater torsion stiffness than the Retron® nail, but we found no significance. The Retron® nail had greater axial stiffness but our findings were not statistically significant.

Our study showed, that there are no significant differences between a retrograde nail and locking plate osteosynthesis for proximal humerus fractures concerning axial and torsion deformities. Therefore the retrograde nail is a suitable alternative for fixation of proximal humerus fracture.


Domenic Grisch Ulf Riede Christian Gerber Bernhard Jost

Background

In elderly patients with complex proximal humerus fractures and osteoporotic bone reconstruction is not always possible. Although hemiarthroplasty is an alternative, non-union or tuberosity migration can lead to inferior functional results. Implantation of a Reverse Total Shoulder Arthroplasty (RTSA) seems to be an interesting alternative. In the present study we retrospectively analyzed the short-term results of RTSA for complex proximal humerus fractures in the elderly.

Methods

From 31.10.2005 to 20.07.2010 RTSA was performed in 29 patients (average age 80 years [67;90], 25 women, 4 man) with subcapital, three- or four-part fracture of the proximal humerus as a primary treatment. All procedures were performed using the Anatomical Inverse Shoulder (Zimmer) with fracture stem. A deltopectoral approach was used in every case with reattachment of the tuberosities. Pain, range of motion, subjected shoulder value (SSV) as well as the Constant score (CS) were used to evaluate shoulder function. Implant positioning and signs of loosening were analyzed on standard x-rays.


Antonio Urda Rafael Luque Alvaro Saez-Arenillas Garcia-Crespo Rodrigo Marco Fernando Luis Lopez-Duran

Introduction

Revision type arthroplasties for the treatment of knee osteoarthritis is an effective and secure procedure. It has different indications, but the most relevant is the revision of a failured primary arthroplasty. In our study, we reviewed the results of another indication, the implantation of a revision type arthroplasty as a primary procedure in cases of severe deformities.

Objectives

To assess the radiological, clinical and functional situation and the quality of life of those patients in whom a revision knee arthroplasty had been implanted in the past years.


Iain Murray Natalie Shur Bayanne Olabi Thomas Shape C Robinson

Background

Acute anterior dislocation of the glenohumeral joint may be complicated by injury to neighboring structures. These injuries are best considered a spectrum of injury ranging from an isolated dislocation (unifocal injury), through injuries associated with either nerve or osteoligamentous injury (bifocal injury), to injuries where there is evidence of both nerve and osteoligamentous injury. The latter combination has previously been described as the “terrible triad,” although we prefer the term “trifocal,” recognizing that this is the more severe end of an injury spectrum and avoiding confusion with the terrible triad of the elbow. We evaluated the prevalence and risk factors for nerve and osteoligamentous injuries associated with an acute anterior glenohumeral dislocation in a large consecutive series of patients treated in our Unit.

Materials and Methods

3626 consecutive adults (mean age 48yrs) with primary traumatic anterior shoulder dislocation treated at our unit were included. All patients were interviewed and examined by an orthopaedic trauma surgeon and underwent radiological assessment within a week of injury. Where rotator cuff injury or radiologically-occult greater tuberosity fracture was suspected, urgent ultrasonography was used. Deficits in neurovascular function were assessed clinically, with electrophysiological testing reserved for equivocal cases.


Zoran Vukasinovic Dusko Spasovski

We present the results of Chiari pelvic osteotomy in the treatment of adolescent hip incongruence, with special interest in identifying possibilities, limitations and complications.

In a series of 86 patients treated by Chiari pelvic osteotomy (13 operated bilateraly) at the Institute for Orthopaedic Surgery “Banjica” with a follow-up period more than 48 months, we analyzed the relation of Chiari-specific parameters collected from postoperative radiograms (osteotomy angle and heigth, and displacement index) to various preoperative and postoperative parameters (Sharp acetabular angle, Wiberg CE angle, Heyman and Herndon femoral head extrusion index (FHEI), Acetabular depth ratio (ADR), Shenton-Menard arch integrity, limb length discrepancy, gait quality) and functional result according to HHS and McKay scoring systems.

We found highly significant improvements of Sharp angle (from 47.2±6.1° preoperatively to 38.6±7.8° finally, p<0.01), Wiberg CE angle (from 10.2±16.8° to 38.9±14.6°, p<0.01) and FHEI (from from 53.4±21% to 1.9±70.7%, p<0.01). In adition, HHS was also improved from 76±15.1 to final 87.9±9.4, p<0.01). We also assessed the satisfaction of both patients (index 4.2 out of 5) and surgeons (index 3.7 out of 5).

Chiari pelvic osteotomy is useful surgical procedure in the selected cases of adolescent hip incongruence with disturbance of hip centering and coverage.


Olof Leonardsson Göran Garellick Johan Kärrholm Kristina Akesson Cecilia Rogmark

Background

In Sweden approximately 6000 patients yearly sustain displaced femoral neck fractures. During the last decade there has been a shift towards more arthroplasties at the expense of internal fixation. In 2008 approximately 75% of the dislocated femoral neck fractures in Sweden were treated with arthroplasties. Those patients are typically elderly and frail and the vast majority of them receive hemiarthroplasties. In 2005 a national hemiarthroplasty registration was established as part of the Swedish Hip Arthroplasty Register (SHAR).

Material & Method

The SHAR aims to register all hemiarthroplasties performed in Sweden, including primary and salvage procedures. Surgical and patient details are recorded and re-operations are registered.


Iain Murray Caroline Foster C Robinson

Background

Non-union has traditionally been considered a rare complication following the non-operative management of clavicle fractures. A growing body of evidence has demonstrated higher rates of non-union in adults with displaced fractures. However, the variables that predict non-union in these patients remain unclear. We evaluated the prevalence and risk factors for non-union following displaced midshaft clavicle fractures in a large consecutive series of patients managed non-operatively in our Unit.

Materials and Methods

1097 consecutive adults (mean age 26.1yrs) with displaced midshaft clavicle fractures treated non-operatively in our Unit were included. All patients were interviewed and examined by an orthopaedic trauma surgeon and underwent radiological assessment within a week of injury. All patients were managed in a simple sling for two weeks followed by early mobilization. All patients were followed-up until clinical and radiological confirmation of union. Non-union was defined clinically as the presence of pain or mobility of the fracture segments on stressing, and radiologically as failure of cortical bridging by 6 months.


Paul Jenkins Delukshan Srikantharajah Jane Mceachan

Introduction

Carpal tunnel syndrome is a common neuropathy of the median nerve. Occupation has been widely examined as a risk factor for the development of carpal tunnel syndrome. The aim of this study was to examine the validity of the United Kingdom (UK) NS-SEC (National Statistics Socioeconomic Classification) in the assessment of correlation between occupation and CTS.

Methods

A prospective audit database was collected of patients diagnosed with CTS over a 6 year period. Occupation was assessed using the NS-SEC self coded method, where occupation is classified depending on the type of job and the size of the employer. UK Census data from 2001 was used to compare the occupation profile of the cohort with the regional population.


Anders Holsgaard-Larsen Ewa Roos

Introduction

Osteoarthritis (OA) of the hip and knee causes pain and functional limitations which lead to decreased physical activity level (1,2). Half of all male, and two thirds of all female, patients with early knee OA do not fulfill the recommendations for physical activity level (30 min/day of at least 5 days/week) (1). We tested the hypothesis that Scandinavian patients prior to total joint replacement had reduced actual physical activity and intensity levels compared with matched controls and that most patients did not fulfill the recommendations for physical activity.

Methods

Physical activity and intensity were measured during 5 consecutive days with SenseWearTM Armband (SWA; BodyMedia, Inc., Pittsburgh, PA) in 53 patients with severe knee (n = 26) or hip (n = 27) OA prior to total joint replacement (51% women, age: 68 ± 5 years, BMI: 29.8 ± 10.2) and compared with data from 15 age-matched population-based controls (53% women, age: 68 ± 5 years, BMI: 26.9 ± 3.3). Sedentary, moderate, vigorous and very vigorous intensities were equivalent to Sense Wear Armband recordings of 3 MET, >36 MET, >69 MET, >9MET, respectively. In addition, total energy expenditure, average MET, numbers of steps/day, and the combined activity of moderate, vigorous, and very vigorous activity were calculated (min/day). Unpaired students t-test was used for between group comparisons (p < 0.05).


Carsten Jensen Soren Overgaard Per Aagaard

Introduction

Total leg muscle function in hip OA patients is not well studied. We used a test-retest protocol to evaluate the reproducibility of single- and multi-joint peak muscle torque and rapid torque development in a group of 40–65 yr old hip patients. Both peak torque and torque development are outcome measures associated with functional performance during activities of daily living.

Material and Methods

Patients: Twenty patients (age 55.5±3.3, BMI 27.6±4.8) who underwent total hip arthroplasty participated in this study. Reliability: We used the intra-class correlation (ICC) and within subject coefficients of variation (CVws) to evaluate reliability. Agreement: Relative Bland-Altman 95% limits of agreements (LOA) and smallest detectable difference (SDD) were calculated and used for evaluation of measurement accuracy. Parameters: Maximal muscle strength (peak torque, Nm) and rate of torque development (Nm•sec-1) for affected (AF) and non-affected (NA) side were measured during unilateral knee extension-flexion (seated), hip extension-flexion, and hip adduction-abduction (standing), respectively. Contractile RTD100, 200, peak was derived as the average slope of the torque-time curve (torque/time) at 0–100, 0–200 and 0 peak relative to onset of contraction. Protocol: After 5 min level walking at self-selected and maximum speeds each muscle group was tested using 1–2 sub-maximal contraction efforts followed by 3 maximal contractions 4s duration. Statistics: The variance components were estimated using STATA12, with muscle function and occasion as independent variable and patients as random factor, using the restricted maximum likelihood method (=0.05).


Aad Dhollander Peter Verdonk Rene Verdonk Gust Verbruggen Karl Almqvist

Aim

The present study was designed to evaluate the implantation of alginate beads containing human mature allogenic chondrocytes for the treatment of symptomatic cartilage defects in the knee.

Methods

A biodegradable, alginate-based biocompatible scaffold containing human mature allogenic chondrocytes was used for the treatment of chondral and osteochondral lesions in the knee. Twenty-one patients were clinically prospectively evaluated with use of the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and a Visual Analogue Scale (VAS) for pain preoperatively and at 3, 6, 9, 12, 24 and 36 months of follow-up.


Miklos Torkos Csaba Gimesi Zoltan Toth Gabor Bajzik Adam Magyar Istvan Szabo

Goal

The goal of this prospective, non-randomized study is to compare functional and life-quality changes in primary total hip replacement (THR) with minimally invasive anterior (MIA) and direct lateral (DL) approach in six months follow-up.

Materials and Methods

Sixty (30 MIA and 30 DL) consecutive patients underwent primary THR were operated by the same senior surgeon. Patients completed functional and life-quality scores (Oxford Hip Score, Harris Hip Score, EQ-5D) before operation and four times (2 and 6 weeks, 3 and 6 months) after THR. Physical examination was taken all times. 15–15 patients underwent MRI examination to adjudge status of abductor muscles. The average patient age was approximately equal in both group.


Christian Gerber Dominik Meyer Katja Nuss Mazda Farshad

Introduction

Following tear of its tendon, the muscle undergoes retraction, atrophy and fatty infiltration. These changes are inevitable and considered irreversible and limit the potential of successful repair of musculotendinous units. It was the purpose of this study to test the hypothesis that administration of anabolic steroids can prevent these muscular changes following experimental supraspinatus tendon release in the rabbit.

Methods

The supraspinatus tendon was experimentally released in 20 New Zealand rabbits. Musculotendinous retraction was monitored over a period of 6 weeks. The seven animals in group I had no additional intervention, six animals in group II had local and seven animals in group III had systemic administration of nandrolone deconate during six weeks of retraction. At the time of sacrifice, in-vivo muscle performance as well as radiologic and histologic muscle changes were investigated.


Christophe Nich Christophe Nich Jean Langlois Arnaud Marchadier Catherine Vidal Martine Cohen-Solal Hervé Petite Moussa Hamadouche

Osteoporosis following ovariectomy has been suggested to modulate bone response to polyethylene wear debris. In this work, we evaluate the influence of estrogen deficiency on experimental particle-induced osteolysis. Polyethylene (PE) particles were implanted onto the calvaria of wild-type (WT), sham-ovariectomized (OVX), OVX mice and OVX mice supplemented with estrogen (OVX+E2) (12 mice per group). Sham-implanted mice served as internal controls. After 14 days, seven skulls per group were analyzed with a high-resolution micro-computed tomography (CT) and by histomorphometry, and for tartrate-specific alkaline phosphatase. Five calvariae per group were cultured for the assay of IL-1, IL-6, TNF- and RANKL secretion using quantitative ELISA. The expression of RANKL and OPG mRNA were evaluated using real-time PCR. As assessed by CT and by histomorphometry, PE particles induced an extensive bone resorption and an intense inflammatory reaction in WT, sham-OVX and OVX+E2 mice. In OVX mice group, these features appeared considerably attenuated. In WT, sham-OVX and OVX+E2 mice, PE particles induced an increase in serum IL-6, in TNF-and RANKL local concentrations, and resulted in a two-fold increase in RANKL/OPG mRNA ratio. Conversely, these parameters remained unchanged in OVX mice after PE implantation. The combination of two well-known bone resorptive mechanisms ultimately attenuated osteolytic response, suggesting a protective effect of estrogen deficiency on particle-induced osteolysis. This paradoxical phenomenon was associated with a downregulation of pro-resorptive cytokines. It is hypothesized that excessive inflammatory response was controlled, illustrated by the absence of increase of serum IL-6 in OVX mice after PE implantation.


Kristoff Corten Chosa Etsuo Michael Leunig Reinhold Ganz

Introduction

Ectopic ossification (EO) at the acetabular rim has been suggested to be associated with pincer impingement and to lead to ossification of the labrum. However, this has never been substantiated with histological, radiographic and MRI findings in large cohorts of patients. We hypothesized that it is more a bone apposition of the acetabular rim and that it occurs more frequently in coxa profunda (CP) hips.

Materials and Methods

In the first part, a cohort of 20 hips with this suspected ectopic rim ossification (EO) pattern were identified. The radiographic features that could be associated with this ossification pattern were described and evaluated by a histologic examination of intra-operative samples taken from the rim trimming. In the second part, we assessed the prevalence of this ectopic ossification process in a cohort of 203 patients treated for FAI.


Aloïs Espié Aloïs Espié Jean-Michel Laffosse Abdelaziz Abid Jérôme Sales De Gauzy

Introduction

Sternoclavicular dislocations are well-known adult injuries. The same traumatism causes growth-plate fracture of the medial clavicle in children and young adults. At this location, the emergence of the secondary ossification center and its bony fusion are late. We report the results of 20 cases hospitalized in the Toulouse University Hospital Center that were treated surgically.

Materials & Methods

20 patients were treated between 1993 and 2007, 17 boys and 3 girls, 16 years old (6–20). The traumatism was always violent (rugby 75%). Two physeal fractures were anteriorly displaced, and 18 posteriorly. The follow-up is 64 month (8–174).

Clinical, radiographic and therapeutic characteristics were assessed. The long-term results were analysed with: an algo-functional scale (Oxford shoulder score), the subjective Constant score, a functional disability scale (Shoulder simple test), a quality of life scale (DASH), and global indicators (SANE and global satisfaction).


Petra Flikweert J Verlaan Ger Van Olden

Introduction

The treatment of clavicle fractures remains controversial. Although most clavicle fractures can be treated successfully nonoperatively, no consensus exists for the complete range of lesions. A systematic literature review was performed to summarize and compare the results of different treatments.

Material and Methods

A Pubmed search on ‘clavicle’ and ‘fracture’ was performed and relevant papers collected. Predefined inclusion/exclusion criteria had to be met and parameters were extracted. The articles were regrouped according to fracture location: midshaft; lateral; or location not specified. Main parameters were: Edinburgh classification; treatment type; complications; pseudarthrosis; cosmetic satisfaction and pain.


Keith Wannomae Ebru Oral Andrew Neils Shannon Rowell Orhun Muratoglu

Introduction

Vitamin E stabilization of radiation crosslinked UHMWPE is done by (1) blending into the resin powder, consolidating and irradiating or (2) diffusing into already consolidated and irradiated UHMWPE and terminally gamma sterilizing. With blending, a higher radiation dose is required for crosslinking to the same level as virgin UHMWPE. With diffusion, the vitamin E amount used is not limited by the crosslink density, but, vitamin E is exposed to terminal sterilization dose of 25–40 kGy, less than the 100–150 kGy used with blending, which may decrease the grafting of the antioxidant onto the polymer. We investigated the efficiency of grafted vitamin E against squlene-initiated accelerated aging.

Methods

Medical grade GUR1050 UHMWPE with vitamin E (0.1 wt%) was irradiated to 150 kGy. Tibial knee insert preforms were irradiated to 100 kGy, diffused with vitamin E using a doping and homogenization procedure. This UHMWPE was used either before or after gamma sterilization. One set of machined blocks (10 × 10 × 6 mm; n = 6) were extracted in boiling hexane for 4 days, then dried. The extracted blocks were doped with squalene at 120°C for 2 hours. One block each was analyzed after doping. The rest were accelerated aged at 70°C and 5 atm. of oxygen for 6 (n = 2) and 14 days (n = 3). Thin sections (150 micron thick) were microtomed and analyzed by Fourier Transform Infrared Spectroscopy to determine a vitamin E index (1245–1275 cm−1 normalized to 1850–1985 cm−1) and an oxidation index (1700 cm−1 normalized to 1370 cm−1) after extraction with boiling hexane for 16 hours and drying.


Dmitry Ptashnikov Rashid Tihilov Vladimir Usikov

Purpose

Assessment of effectiveness of spinal fixation in conditions of general osteoporosis.

Material and methods of studies

112 patients with multiple osteoporotic pathological vertebral body fractures were surgically treated. Multilevel laminar or transpedicular instrumentation with or without ventral stabilization (group A) was used on 64 of them. The cemented polyaxial screws were used in 48 cases (group B). The patients treated with multilevel transpedicular fixation with cemented screws were included in B-I subgroup. The patients treated with monosegmental fixation (around fractures) with same screws were included in B-II subgroup. The parameters of stability (bone resorption around screws and cement, dislocation of implants, clinical symptoms) were studied in both groups.

Outcome results and discussion: In group “A” the parameters of stability were the purest. The displacement of instrumentation with lost of correction has been revealed in 21% of cases. The reoperations were done in 17% of them. In groups B-I and B-II the parameters of stability were the same. There were no clinical signs of instability up to2 years of supervision. In 75% of cases the bone resorption around bone cement has been revealed after 3–6 months. But there were no cases of instrumental displacement.

Spinal fixation in treatment of multiple pathological vertebral body fractures in conditions of general osteoporosis using the vertebroplasty with cemented screws provide good stability of the spine for long outcome. This method allows to achieve the clinical result with less invasive approach by shortening of extent of fixation.


Ingrid Milosev Simon Kovac Rihard Trebse Vesna Levasic Matevz Topolovec Venceslav Pisot

Introduction

Alternative bearings – metal-on-metal and ceramic-on-ceramic bearings have been introduced in the last decade with the aim to diminish wear and, subsequently, aseptic loosening and osteolysis. These bearings were aimed for younger, more active patients. Clinical results which would compare the performance of various alternative and traditional bearings are scarce.

Methods

Between January 2000 and December 2002, we performed 487 total hip replacements in 474 patients using three types of bearings: metal-on-metal (MOM), metal-on-polyethylene (MOP), and ceramic-on-ceramic (COC). All patients received the same type of acetabular cup (Bicon-Plus, Plus Orthopedics) and same type of femoral component (SL-Plus, Plus Orthopedics). We used the hospital computer database for the evaluation of patient data and data on revision operations.


John Weston-Simons Hemant Pandit Vikram Haliker Andrew Price Chrsitopher Dodd Mansukh Popat David Murray

Introduction

The peri-operative analgesic management of patients having either Total Knee Replacement (TKR) or Unicompartmental Knee Replacement (UKR) is an area that continues to have prominence, driven in part by the desire to reduce hospital stay, while maintaining high patient satisfaction. This is particularly relevant in the current climate of healthcare cost savings. We evaluated the role of “top up” intra-articular local anaesthetic injection after identifying that an appreciable number of patients in the unit suffered “breakthrough pain” on the first post-op day, when the effects of local analgesia are wearing off.

Method

43 patients, who were scheduled to have a cemented Oxford UKR, were prospectively recruited and randomised. All patients had the same initial anaesthetic regime of general anaesthesia, femoral nerve block and intra-operative intra-articular infiltration of the cocktail. All patients had a 16G multi-holed epidural catheter placed intra-articularly prior to wound closure. Patients had the same operative technique, post operative rehabilitation and rescue analgesia.

An independent observer recorded post-operative pain scores using a visual analogue score (1–10) every 6 hours and any rescue analgesia that was required. On the morning after surgery, 22 patients, (Group I), received 20 mls of 0.5% bupivicaine through the catheter whilst 21 patients, (Group II), had 20 mls of normal saline by the same observer, (who was blinded to the contents of the solution being injected), after which the catheter was removed.


Paul Beaulé Craig White Sasha Carsen Kevin Rasuli Steve Doucette

Introduction

Modern cementless press fit stems rely on early fixation and stability for osteointegration and longterm success with early migration increasing the risk of failure. The Ein Bild Roentegen Analyse Femoral Component Analysis (EBRA-FCA) methods allow accurate measurement of femoral stem subsidence without the need for Tantalum markers. The degree of subsidence of femoral stems in the first two years has been shown to be highly predictive of failure when using the cut off value of 1.5 mm. We aimed to measure the early migration pattern of a titanium alloy, tapered, plasma and hydroxyapatite coated femoral stem and any factors associated with subsidence.

Methods

Between January 2005-June 2007, 387 Accolade cementless femoral stems (Stryker, Allendale NJ) were implanted at our institution. Seventy-seven had a minimum of two years post operative follow up and a complete set of pre and postoperative radiographs for analysis. Our group inlcuded 45 females with a mean age of 71.4 years, and 32 males with a mean age of 68.5 years. The primary diagnosis was degenerative osteoarthritis in 71 patients, avascular necrosis in two, and post fracture in four patients. The average BMI was 27.1. We measured the canal index to assess bone quality and the canal calcar index to assess the proximal femoral morphology. Immediate postoperative radiographs were assessed for canal fill of the prosthesis and implantation varus/valgus angles. The EBRA-FCA software was used to obtain migration curves for each stem.


Moataz El-Husseiny Catherine Pendegrass Fares Haddad Gordon Blunn

Introduction

Intraosseous transcutaneous amputation prostheses (ITAP) provide an alternative means of attaching artificial limbs for amputees. Conventional stump-socket devices are associated with soft tissue complications including; pressure sores and tissue necrosis. ITAP resolves these problems by attaching the exo-prosthesis transcutaneously to the skeleton. The aim of this study is to increase the attachment of dermal fibroblasts to titanium alloy in vitro. Fibronectin (Fn) and laminin 332 (Ln) enhance early cell growth and adhesion. We hypothesize that silanized dual coatings of fibronectin and laminin (SiFnLn) will be more durable when compared with adsorbed dual coating (AdFnLn), and will enhance early fibroblast growth and adhesion compared to single coatings.

Methods

The kinetics of dual single and dual protein coating attachment onto titanium alloy was quantified on silanized 10mm diameter discs using radiolabelled Fn (125I-Fn) and Ln (125I-Ln). Sixty discs were polished, sterilized and silanized. Coating durability was assessed when soaked in fetal calf serum (FCS) for 0, 1, 24, 48 and 72hrs. Data was compared to un-silanized Ti discs with the same coatings. Five thousand human dermal fibroblasts were seeded on discs (n = 6) of Ti polished alone (Pol), Ti with adsorbed fibronectin (AdFn), Ti with adsorbed laminin (AdLn), Ti adsorbed dual coating (AdFnLn), Ti silanized (Si), Ti silanized with fibronectin (SiFn), Ti silanized with laminin (SiLn), Ti silanized with a dual coating (SiFnLn) for 24hrs. In order to measure cell adhesion fibroblasts were fixed, vinculin stained using mouse vinculin antibody and alexa fluor. Axiovision Image Analysis software was used to measure cell area, vinculin focal adhesion markers per cell and per unit cell area. Data was analysed in SPSS and significance was assumed at the 0.05 level.


Moataz El-Husseiny Catherine Pendegrass Sherif Elnikety Fares Haddad Gordon Blunn

Introduction

Following amputation, residual stumps used to attach the external prostheses can be associated with sores, infection and skin necrosis. These problems could be overcome by off loading the soft tissues. Intraosseous transcutaneous amputation prostheses (ITAP) attach external implants directly to residual bone reducing these complications. However, a tight seal at the skin implant interface is crucial in preventing epithelial down-growth and infection. Fibronectin (Fn) and laminin 332 (Ln), enhance early cell growth and adhesion of keratinocytes. Silanization to titanium alloy (Ti) allows these proteins to bond to the metal directly. We hypothesize that silanized dual coatings of fibronectin and laminin (SiFnLn) will be more durable than absorbed proteins and that keratinocyte adhesion will be increased compared with Ti controls and single silanized proteins.

Methods

10 mm diameter Ti alloy discs were polished, sterilized and silanized. The kinetics of silanized single and dual protein coating attachment onto titanium alloy was quantified using radio-labelled Fn(125I-Fn) and Ln(125I-Ln). Coating durability was assessed when soaked in fetal calf serum (FCS) for 0, 1, 24, 48, 72hrs. Data was compared to un-silanized Ti discs with the same amount of adsorbed proteins. In order to study cell attachment 20 × 103 keratinocytes were seeded on the discs (n = 6): silanized (Si), silanized fibronectin (SiFn), silanized laminin (SiLn), silanized dual coating (SiFnLn) for 1, 4 and 24hrs. Adhesion of cells was assessed using mouse vinculin antibody for 2hrs and alexafluor for 1hr which stains focal adhesions responsible for attaching cells to surfaces. Axiovision Image Analysis software was used to measure cell area, vinculin markers per cell unit and per unit cell area on 15 cells per disc. Data was analysed in SPSS and significance was assumed at the 0.05 level.


Ahmad Allam

Background

In poliomyelitis; hand to knee gait is the sum of quadriceps weakness and fixed knee flexion deformity. Limb shortening is another added problem. Usually, each problem is attacked separately; with variable end results and complication rates for each procedure.

Patients and methods

22 patients (16–46 y.); with poliomyelitis with hand to knee gait due to fixed knee flexion deformity of mild to moderate degree (10–400); and limb shortening of 4.5–9.5 cm., were managed simultaneously by a single operation. A distal femoral metaphyseal anterior closing wedge (recurvatum) corrective osteotomy was done to treat acutely the fixed knee flexion deformity(and subsequently hand to knee gait). A modified Wagner or Orthofix frame was applied as a mono-plane mono-axial lengthening device to stabilize the osteotomy and to lengthen the short limb. Lengthening was started in all cases two weeks post-operatively.


Muhammad Umar Vijay Patil Simon Lewthwaite

Quality of cementation in the early postoperative period has been proven to be an indicator of long-term survival of the total hip arthroplasty. Cementation grading described by Barrack et al is widely used but has certain limitations. It is based upon second-generation cementation technique and has unacceptably high inter- and intra-observer variability due to its subjective evaluation method.

We are introducing a new grading system of quality of femoral cementation. It is based upon the ratio of the length of radiological lucency to the total length of cement-bone interface on both antero-posterior and lateral views. Because of its objective nature, it is likely to show reproducible results.

We recruited five observers of various grades of surgical experience (trainees to consultant). Each observer graded the quality of femoral cementation on immediate postop xrays twice (gap of atleast two weeks) of 30 primary hip arthroplasties, using Barrack's grading and a new cementation index measured by dividing the ength of Radiolucency along CBI by the total Length of CBI.

Statistical analysis was performed by SPSS v17.0. Inter-observer and Intra-observer variability was determined by Intraclass Correlation Coefficient for a two way mixed model.

New cementation index showed excellent agreement for both inter and intra-observer reliability with intraclass correlation coefficient of 0.79 and 0.82 respectively. On contrary, results of inter-observer reliability for Barrack's grading were poor with value of 0.20. intra-observer reliability was found to be fair with 0.55.

As evident from this study, it is a more reliable way of assessing the quality of cementation, with excellent agreement in both inter and intra-observer categories.


Matevz Topolovec Ingrid Milosev Andrej Coer Roy Bloebaum

Background

Wear particles are considered to be the major culprit for the aseptic loosening. Their characterization is thus crucial for the understanding of their bioreactivity and contribution to the development of aseptic loosening.

Methods

Metal wear debris particles were analyzed directly in periprosthetic tissue resins by scanning electron microscopy (SEM) combined with back-scattered electron imaging (BSE) and energy dispersive X-ray spectroscopy (EDS). Four groups of tissue samples retrieved at revision operations of loosened hip implants with different bearing surfaces (metal-on-metal, ceramic-on-polyethylene and metal-on-polyethylene), and different material of the femoral stem (Ti alloy, CoCrMo and polymer combined with stainless steel) were investigated. Tissue samples were first analyzed histologicaly. Sections from the same paraffin blocks were then carbon coated and analyzed using SEM/BSE/EDS method.


Giulio Maria Marcheggiani Muccioli Stefano Zaffagnini Nicola Lopomo Danilo Bruni Marco Nitri Tommaso Bonanzinga Alberto Grassi Giovanni Ravazzolo Massimo Molinari Eugenio Rimondi Maurilio Marcacci

Purpouse

We hypothesized that patients receiving a medial collagen meniscus implant (MCMI) would show better clinical, radiograpich and Magnetic Resonanace Imaging (MRI) outcomes than patients treated with partial medial meniscectomy (PMM) at minimum 10 year FU.

Material and Methods

Thirty-three non-randomized patients (males, mean age 40 years) were enrolled in the study to receive a MCMI (17 patients) or as control treated with a PMM (16 patients).

All of them were clinically evaluated at time zero, 5 and minimum 10 years after surgery (mean FU 133 months, range 120–145) by Lysholm, VAS for pain, objective IKDC knee form and Tegner activity level. SF-36 score was performed pre-operatively and at final FU.

Bilateral weight-bearing XRays were executed at time zero and at final FU. Minimum 10 years FU MRI images were compared with collected pre-operative MRI images by means of Yulish score. Genovese score was also used to evalute MCMI MRI survivorship.


Mona Badawy Birgitte Espehaug Kari Indrekvam Ove Furnes

Background

Improving quality and efficiency is a priority in health policy. Several studies have shown a correlation between high hospital volume and improved results of surgery. In Norway, orthopaedic surgeons operate a relatively low number of total knee replacements compared with other countries. The number of total knee replacements has, however, increased significantly over the past 10 years.

Some studies have also shown an association between surgeon volume and outcomes after total knee arthroplasty (TKA).

Purpose

We wanted to study a possible correlation between prosthesis survival and surgery volume of TKA, both with respect to hospital volume and surgeon volume.


Alison Traynor David Simpson Peter Ellison Simon Collins

Introduction

Cobalt chrome on polyethylene remains a widely used bearing combination in total joint replacement. However wear induced osteolysis, bulk material property degradation of highly cross-linked polyethylene (HXLPE) [1], and oxidation after implantation (thought to be as a result of lipid absorption or cyclic loading [2]) remains a concern. ECIMA is a cold-irradiated, mechanically annealed, vitamin E blended next generation HXLPE developed to maintain mechanical properties, minimise wear and to improve the oxidation resistance in the long-term. The aim of this study was to compare the in-vitro wear rate and mechanical properties of three different acetabular liners; conventional UHMWPE, HXLPE and ECIMA.

Methods

Twelve liners (Corin, UK) underwent a 3 million cycle (mc) hip simulation. Three conventional UHMWPE liners (GUR1050, Ø32 mm, 30 kGy sterilised in Nitrogen), three HXLPE liners (GUR1020, Ø40 mm, 75 kGy cross-linking and EtO sterilised) and six ECIMA liners (0.1 wt% vitamin E GUR1020, Ø40 mm, 120 kGy cross-linking, mechanically deformed and annealed, and EtO sterilised) articulated against CoCrMo alloy femoral heads to ASTM F75 (Corin, UK). Wear testing was performed in accordance with ISO 14242 parts 1 and 2, with a maximum force of 3.0 kN and at a frequency of 1 Hz. The test lubricant used was calf serum with a protein content of 30 g/l and 1% (v/v) patricin added as an antibacterial agent. Volumetric wear rate was determined gravimetrically after the first 0.5 mc and every 1 mc thereafter.

ASTM D638 type V specimens (3.2 mm thick) were machined from ECIMA material for uniaxial tension testing to ASTM D638. Ultimate tensile strength (UTS), yield strength and elongation values were measured. These values were compared to mechanical data available for the other material types.


Maria Vlachou Alexis Verikokakis Dimitris Dimitriadis

The purpose of the study is to evaluate the retrospective results of 92 surgically treated spastic hips. Twenty-one patients were able to walk in the community with aids, 19 were able to walk about the house, and 13 were wheelchair bound. The mean age at the time of the operation was 7 yrs (3–18) and the average follow-up was 5. The cohort of the study included 45 tetraplegic patients, 6 diplegic, and 2 hemiplegic. The dislocated hips were 25 and the subluxated ones 67.

The surgical treatment included soft tissue and bone procedures. The 53 patients were divided into two age groups: those less than 7yrs old and those older than 7yrs. The cohort was also divided into 39 patients operated in one setting, and 14 operated in more than one. Clinical evaluation was based on the joint range of motion, the ambulatory status and the pain. The radiological evaluation criteria were based on Reimer's migration index, the center-edge angle, Sharp's angle, and neck-femoral angle. We used the interclass correlation coefficient to measure our interobserver reliability for MI 0,93, for CE angle 0,95 and for Sharp's angle 0,81, as the interobserver difference for MI averaged 9% for CE angle 7and for Sharp's angle 3.

Statistical analysis of continuous variables was done by Student's t-test or the Wilcoxon rank sum test. Categorical variables were evaluated by Fisher's test. Concerning the walking ability, from the 13 severe quadriplegic patients, none improved his functional level but they achieved better sitting balance. The walking ability of the rest of the patients improved one level in 78% of the cases. The mean preoperative abduction was improved from 24,7 to 33,5, the mean flexion was slightly reduced from 123 preoperatively to 114 postoperatively and the mean extension reduced from −20 preoperatively to −8 postoperatively. Reimer's index reduced from 67,2 to 21,7 postoperatively, the CE angle increased from −10,6 to 20,5, the Sharp's angle increased from 36,9 to 40,5 and the neck-shaft angle increased from 119,7 to 157,5post-operatively. Of greater significance were MI and CE at p<0.05. A migration index of >50% at final follow-up was associated with a worse migration index and a worse CE angle at 1 year post-operatively. 46 hips were evaluated as good, 30 as satisfactory, and 16 as poor. The severe tetraplegic with small-negative CE angle and Reimer's migration index > 50%, as well as the small age of the patients (<7 yrs) were negative prognostic factors. Better results were observed when patients were operated at age <7yrs by soft tissue procedures and MI<30%, while patients >7yrs had satisfactory results only after combined bony and soft tissue procedures and MI <50%. A migration index of >50% at final follow-up was associated with a worse migration index and a worse CE angle at 1 year postoperatively.


Danilo Bruni Giovanni Raspugli Francesco Iacono Mirco Lo Presti Stefano Zaffagnini Maurilio Marcacci

Background

The reported outcomes of unicompartmental knee replacement (UKR) for spontaneous osteonecrosis of the knee (SPONK) often derive from small series with an average followup of 5 years, enabling to generate meaningful conclusions. Therefore, we determined the long-term functional results and the 10-years survivorship of the implant in all patients with advanced SPONK of the medial tibio-femoral compartment treated with a unicompartmental knee arthroplasty at our institute.

Methods

We retrospectively evaluated 84 consecutive patients with late stage SPONK. All patients received a pre-operative MRI to confirm the diagnosis, to exclude any metaphyseal involvement and to assess the absence of significative degenerative changes in the lateral and PF compartment. Mean age at surgery was 66 years and mean body mass index (BMI) was 28.9. In all cases, SPONK involved the medial compartment; in 77 cases the medial femoral condyle (MFC) was involved, while in 7 cases the pathology site was the medial tibial plateau (MTP). Radiological evaluation was conducted by 3 different radiologists and clinical evaluation according to KSS and WOMAC score was performed by 3 fellows from outside institutions, with no previous clinical contact with the patients, at a mean followup of 98 months.


Edward Tayton Spandan Kalra Adam Briscoe Alexander Aarvold James Smith Stuart Lanham Sherif Fahmy Steve Howdle Kevin Shakesheff Douglas Dunlop Richard Oreffo

Background

Impaction bone grafting with milled human allograft is the gold standard for replacing lost bone stock during revision hip surgery. Problems surrounding the use of allograft include cost, availability, disease transmission and stem subsidence (usually due to shear failure of the surrounding allograft). Aims. To investigate various polymers for use as substitute allograft. The ideal graft would be a composite with similar mechanical characteristics as allograft, and with the ability to form de novo bone.

Methods

High and low molecular weight (MW) forms of three different polymers (polylactic acid (PLA), poly (lactic-co-glycolic) acid (PLGA) and polycaprolactone (PCL)) were milled, impacted into discs, and then tested in a custom built shear testing rig, and compared to allograft. A second stage of the experiment involved the addition of skeletal stem cells (SSC) to each of the milled polymers, impaction, 8 days incubation, and then tests for cell viability and number, via fluorostaining and biochemical (WST-1, DNA) assays.


Maria Vlachou Alex Beris Dimitris Dimitriadis

The equinovarus hind foot deformity is one of the most common deformities in children with spastic paralysis and is usually secondary to cerebral palsy. Split posterior tibialis tendon transfer is performed to balance the flexible spastic varus foot and is preferable to posterior tibialis lengthening, as the muscle does not loose its power and therefore the possibility of a valgus or calcaneovalgus deformity is diminished. The cohort of the study consisted of 50 children with cerebral palsy who underwent split posterior tibial lengthening to manage spastic equinovarus hind foot deformity. Our inclusion criteria were: ambulatory patients with cerebral palsy, age less than 6 years at the time of the operation, varus deformity of the hind foot during gait, flexible varus hind foot deformity, and the follow-up at least 4 years. We retrospectively evaluated 33 ambulant patients with flexible spastic varus hind foot deformity. Twenty-eight patients presented unilateral and 5 bilateral involvement. The mean age at the time of the operation was 10,8 years (6–17) and the mean follow-up was 10 years (4–14). Eighteen feet presented also equinus hind foot deformity, requiring concomitant Achilles cord lengthening. Clinical evaluation was based on the inspection of the patients while standing and walking, the range of motion of the foot and ankle, callus formation and the foot appearance using the clinical criteria of Kling et al. Anteroposterior and lateral weight-bearing radiographs of the talo-first metatarsal angle were measured. The position of the hind foot was evaluated according to the criteria of Chang et al for the surgical outcome. 20 feet were graded excellent, 14 were graded good and 4 were graded poor. Feet with recurrent equinovarus deformity or overcorrection into valgus or calcaneovalgus deformity were considered as poor results. There were 23 feet presenting concomitant cavus foot component that underwent supplementary operations performed at the same time with the index operation. None of the feet presented mild or severe valgus postoperatively, while 4 feet presented severe varus deformity and underwent calcaneocuboid fusion sixteen and eighteen months after the index operation. On the anteroposterior and lateral weight-bearing radiographs the feet with severe varus had a negative talo-first metatarsal angle (mean −26,8 ± 18,4), those with mild varus had a mean of −14,5 ± 12,2. In feet with the hind foot in neutral position the mean value was 5.0 ± 7.4. The results of the feet in patients with hemiplegic pattern were better and significantly different than the diplegic and quadriplegic ones (p = 0.005). The results in our cases were in general satisfactory as 34 out of 38 feet were graded excellent and good. The feet with poor results presented a residual varus deformity due to intraoperative technical errors.


Thomas Ball Christopher Day David Strain Peter Cox

Aims

We investigated the local epidemiology of Developmental Dysplasia of the Hip (DDH), in order to define incidence, identify risk factors, and refine our policy on selective ultrasound screening.

Methods

Data were recorded prospectively on all live births in the Exeter area from January 1998 to December 2008. We compared those treated for DDH with all other children. Crude odds ratios (OR) were calculated to identify potential risk factors. Logistic regression was then used to control for interactions between variables.


Martin Gottliebsen Ole Rahbek Kjeld Soballe Maiken Stilling

Background

An increasing number of hip prostheses are inserted without bone cement. Experimental research has shown that hydroxyapatite (HA) coated implants are strongly fixated in the bone, which is believed to reduce the likelihood of prosthetic loosening. However, in recent years, there has been much debate about the role of HA particles in third-body polyethylene (PE) wear and formerly we have shown the revision rate to be high among older-design HA coated cups.

Purpose

We hypothesized increased PE wear-rate using HA coated acetabular components in comparison with non-HA coated components (control group).


Christiaan Van Bergen Murat Özdemir Gino Kerkhoffs Clara Korstjens Leo Van Ruijven Vincent Everts C Van Dijk Leendert Blankevoort

Introduction

Osteochondral defects (OCDs) of the talus are treated initially by arthroscopic bone marrow stimulation. For both large and secondary defects, current alternative treatment methods have disadvantages such as donor site morbidity or two-stage surgery. Demineralized bone matrix (DBM) was published for the treatment of OCDs of rabbit knees. Autologous platelet-rich plasma (PRP) may improve the treatment effect of DBM. We previously developed a goat model to investigate new treatment methods for OCDs of the talus. The aim of the current study was to test whether DBM leads to more bone regeneration than control OCDs, and whether PRP improves the effectiveness of DBM.

Methods

A standardized 6-mm OCD was created in 32 ankles of 16 adult Dutch milk goats. According to a randomized schedule, 8 goats were treated with commercially available DBM (Bonus DBM, Biomet BV, Dordrecht, the Netherlands) hydrated with normal saline, and 8 were treated with the same DBM but hydrated with autologous PRP (DBM+PRP). The contralateral ankles (left or right) were left untreated and served as a control. The goats were sacrificed after 24 weeks and the tali were excised. The articular talar surfaces were assessed macroscopically using the international cartilage repair society (ICRS) cartilage repair assessment, with a maximum score of 12. Histologic analysis was performed using 5-μm sections, and histomorphometric parameters (bone% and osteoid%) were quantified on representative areas of the surface, center, and peripheral areas of the OCDs. Furthermore, μCT-scans of the excised tali were obtained, quantifying the bone volume fraction, trabecular number, trabecular thickness, and trabecular spacing in both the complete OCDs and the central 3-mm cylinders.


David Gordon Robyn Zicker Nicholas Cullen Dishan Singh Maureen Monda

Introduction

Debate remains which surgical technique should be used for ankle arthrodesis. Several open approaches have been described, as well as the arthroscopic method, using a variety of fixation devices.

Both arthroscopic and open procedures have good results with union rates of 93–95%, 3% malunion rate and patient satisfaction of 70–90%, although some report complication rates as high as 40%.

Aims

To identify union, complication and patient satisfaction rates with open ankle fusions (using the plane between EHL and tibialis anterior).


Stefaan Nijs Francois Hardeman

Introduction

Analysing the results of angular stable osteosynthesis in large groups of patients can give us an indication of the possibilities and limitations of both angular stable nailing and plating.

Material and Methods

Fractures have been classified using the AO-classification system.

To judge vascularisation of the head fragment we use the criteria as described by Hertel.

We considered fracture reduction as adequate when the CCD-angle could be restored, with a maximum of 10° varus or valgus malalignment and a maximal persistent tuberosity displacement equal to or less than 3 mm in any direction.

An independent investigator collects information on reoperations based on: patient interview, hospital data and contact with the operating surgeon if the revision took place elsewhere. Reoperation is defined as any secondary surgical procedure after the initial open reduction and fixation.


Walter Van Der Weegen Henk Hoekstra Thea Sybesma Ellis Bos Emil Schemitsch Rudolf Poolman

Background

Hip resurfacing arthroplasty (HRA) has seen a recent revival with third generation Metal-on-Metal prostheses and is now widely in use. However, safety and effectiveness of hip resurfacing are still questioned. We systematically reviewed peer-reviewed literature on hip resurfacing arthroplasty to address these issues.

Objective

To evaluate implant survival and functional outcomes of hybrid Metal-on-Metal hip resurfacing arthroplasty (HRA).


Pietro De Biase Rodolfo Capanna Domenico Campanacci Giovanni Beltrami Guido Scoccianti Andrea Piccioli

The reconstruction of lower limb defects after oncological reconstructions is still a problem in limb salvage surgery. Large bony defects need to be treated with sound and durable reconstructions. During recent decades, the life expectancy of patients affected with cancer has improved considerably because of advances in chemotherapy, immunotherapy, hormonal treatment and radiotherapy. This improvement requires greater reliability in the reconstructive procedure in order to avoid mechanical failure during prolonged survival of the patient. The author experience with modular megaprosthesis by Link (megasystem C) allowed us to present a rapid, effective and functional solution.

From June 2001 to December 2007 225 patients have been operated with a megaprosthesis C for tumoral resection. The new megaprosthesis C by Link represents a wide-ranging system that can afford a large variety of reconstructions in the inferior limb, from very short replacement of 5 cm in proximal femur, to a total femur and proximal tibia replacement. Modularity is represented by 1 cm increase in length. The different options of cemented and not cemented stem may be used with intraoperative decision. In cemented stem a rough collar seals the osteotomy and prevents polyethylene debris from entering the femoral canal by inducing a scar tissue around the stem entrance (so-called purse-string effect). Moreover in patients with solitary lesions and very good prognosis an allograft-prosthesis composite can be performed with improved clinical results on walking and function. Of the 225 patients that underwent tumoral resection and reconstruction with a modular megaprosthesis approximately 43% (97 cases) were operated for metastatic disease. Among these cases 55 cases were proximal femoral recontructions, 39 cases were distal femoral reconstructions and 3 cases were proximal tibial reconstructions. All cases were performed with cemented stems. We experienced a 7% of postoperative infections, 2% of dislocations of proximal femoral prosthesis and 3% of mechanical failures. While infections and dislocation rates were in the average for this surgery, mechanical failures were relatively high. We should consider that in patients with relatively long resections and muscle deficiency the mechanical stress exerted on the prosthesis can explain this kind of mechanical failure. However the new design of morse tapers have annulled these problems


Daren Lim Fat Jim Kennedy Rose Galvin Fergal O'brien Hannan Mullett

Title

3D distribution of cortical bone thickness in the proximal humerus, implications for fracture management.

Introduction

CT imaging is commonly used to gain a better understanding of proximal humerus fractures. the operating surgeon however has a limited capacity to evaluate the internal bone geometry from these clinical CT images. our aim was to use clinical CT in a novel way of accurately mapping cortical bone geometry in the proximal humerus. we planned to experimentally define the cortico-cancellous border in a cadaveric study and use CT imaging software to map out cortical thickness distribution in our specimens.


Andreas Leonidou Panagiotis Lepetsos Ioannis Flieger Nikolaos Pettas Konstantinos Antonis Omiros Leonidou

Introduction

The incidence of spondylolysis is estimated about 5–6% in the general population and accounts for one of the most frequent cause of backpain in the adolescent. The purpose of this study is to present our results from the management of these patients.

Patients and Methods

During the period 1993–2003, 25 children with spondylolysis and spondylolisthesis were managed in our department. Apart from radiographic studies, in cases with a history of acute trauma, a bone scan as well as a CT or MRI scan were performed. There were 13 male and 12 female patients with a mean age of 10.5 years (5–14 years). There were 15 cases of spondylolysis, one at L3 level, 3 at L4 and 11 at L5. 10 patients had spondylolisthesis, 8 of the isthmic type and 2 of the dysplastic type. THe mean follow up of the patients was 6.5 years.


Andreas Leonidou Nicholas Boyce Cam Iain Chambers

Introduction

Femoral neck fractures are an increasingly common injury in the elderly. Frequently these patients present taking Clopidogrel, an irreversible inhibitor of platelet aggregation. Although this is associated with an increased risk of intra-operative bleeding and also an increased risk of spinal haematoma where regional anaesthesia is employed, the recent SIGN (Scottish Intercollegiate Guidance Network) guidelines recommend that surgery should not be delayed.

Methods

We conducted a retrospective review of consecutive patients admitted with femoral neck fractures between April 2008 and October 2009. Patients on Clopidogrel were identified and data including ASA grade, time to operation, medical co-morbidities, and post-admission complications were recorded. Comparative information from the National Hip Fracture Database was used.


Ole Rahbek Soren Deutch Soren Kold Jens Ole Soejbjerg Bjarne Moeller-Madesen

Introduction

Chronic radial head dislocation in children after trauma is a serious condition. Often the dislocation is overseen initially and is a part of the Monteggia fracture complex with anterior bowing of the ulna. Typical complaints are pain, decreased ROM and cubitus valgus. Radial head dysplasia often occurs. The treatment of this condition is debated. Only few series of patients treated with open reduction and ulnar osteotomy exists with long-term follow up. We present a group of rare patients with long-time follow-up treated by only two surgeons through a period of 16 years.

Materials and Methods

All 16 patients had anterior radial head dislocation (Bado type 1). Mean age at the time of traumatic dislocation was 6 years ranging from 2 to 9. We found a mean delay of 17 (range 1–83) months before open reduction and ulnar open wedge osteotomy. In 8 cases reconstruction of the annular ligament was performed and in 6 patients temporary transarticular fixation of the radial head with a k-wire was performed. Follow-up time was 8 (range 3–17) years postoperatively. Patients were investigated with bilateral x-ray, arthrosis status, congruency of the radiocapitellar joint, Oxford Elbow Score, force measurements and range of motion.


Philipp Funovics Stefan Rois Rainer Kotz Martin Dominkus Reinhard Windhager

Background

Modular endoprostheses today represent a standard treatment option in the management of musculoskeletal tumors of the lower extremities. Long-term results of these reconstructions, however, are often limited by the course of the underlying disease. We therefore report our experiences in cancer patients with megaprostheses of the lower limb after a minimum of 15 years.

Materials and Methods

62 patients, 34 men and 28 women, with a mean age of 26 years (median, 20; range, 6–83) were included in this investigation with a mean follow-up of 230 months (median, 228; range, 180–342). Endoprosthetic reconstructions of the proximal femur (11), the distal femur (28), the total femur (2) or the proximal tibia (21) were indicated for osteosarcoma (43), chondrosarcoma (5), malignant fibrous histiocytoma (3) or other tumors (11). All patients have received either a KMFTR (22) or a HMRS (40) modular prosthesis; 23 patients had a muscle flap, 14 had a fibular transposition osteotomy and 4 have received an artificial LARS ligament for soft-tissue reconstruction.


Michal Latalski Marek Fatyga Andrzej Gregosiewicz

Introduction

The aim of the treatment of children with early onset scoliosis is controlling growth of the spine. Whatever the etiology, early progressive deformations require multiple stages of surgery usually performed every 6–12 months. One have to be reckoned with complications requiring additional surgical intervention.

Objective

The aim of the study is to present a new method of surgical treatment of early onset scoliosis involving the implantation of specially constructed implants to allow three dimensional correction of spinal deformity with a preserved capacity to continue the growth of spine without distraction staged operations followed by final spondylodesis in mature spine.


William Blakeney Riaz Khan Li-On Lam William Breidahl

Background

The long-term impact of dividing Piriformis when performing a standard posterior approach to the hip has not been assessed. A less invasive approach in which the tendon is preserved has been described (the Piriformis-sparing minimally invasive [PSMI] approach). With advances in MRI technology it is now possible to image structures in close proximity to metal without artifact. The aim of the study was to compare the MRI features (muscle grade and bulk) of the divided and repaired Piriformis tendon group (by the standard posterior approach) with the preserved tendon group (by the PSMI approach).

Methods

As part of an on-going randomized controlled trial comparing the PSMI approach with the standard posterior approach for total hip replacement, a subgroup of 20 consecutive patients who fulfilled the inclusion criteria were recruited. Patients received preoperative and 3 months and 2 year postoperative MRI scans. Patients and evaluators were blinded to allocation. Outcomes assessed included grade, volume and integrity of Piriformis.


Luigi Costa Marco Regis Pierangiola Bracco Luca Giorgini Simonetta Fusi

Recent findings about UHMWPE oxidation from in vivo stresses lead to the need of a better understanding of which anti-oxidant additivation method is the best option for the use in orthopaedic field. A GUR 1050 crosslinked Vitamin E - blended UHMWPE has been investigated, to provide an accurate outline of its properties.

DSC and FTIR measurements, together with ageing and tensile tests were performed on compression moulded blocks, as well as biocompatibility tests, including implantation on rabbits. Moreover, wear simulations on finished components (Delta acetabular liners) have been completed.

All the test procedures have been repeated for a reference material, a GUR 1050 crosslinked and remelted standard UHMWPE (commercial name UHMWPE X-Lima), and the outcomes have been compared to the crosslinked Vitamin E - blended UHMWPE ones.

On the additivated UHMWPE, we found a ultimate tensile strength of 43 MPa, a yield strength value of 25 MPa, and an elongation to breakage equal to 320%. The degree of cristallinity was 45 ± 2%, and no signal of creation of oxidation products was detected up to 2000 h of permanence in oxidant ambient after the ageing test. The reference material showed comparable mechanical resistance values (∗ = 40 MPa, y = 20 MPa, 350% elongation), a cristallinity of 46 ± 2%, and the creation of oxidation products starting from 700 h in oxidant ambient. The biocompatibility tests indicate that the additivated material is biocompatible, as the reference X-Lima UHMWPE.

Wear tests gave a wear rate of 5,09 mg/million cycles against 6,13 mg/million cycles of the reference material, and no sign of run in wear rate.

Our results indicate that there is no change in mechanical properties in respect to the reference material. This is confirmed by DSC measurements, that show no change in cristallinity. The blend between polymer and additive assures an uniform concentration of Vitamin E across the whole thickness of the moulded block, and ageing test results on additivated UHMWPE have shown that the material possess a superior resistance to degradation phenomena.

Biocompatibility assess that the presence of Vitamin E is not detrimental for the in vivo use of the material, and wear results indicate a better wear resistance of the material, especially in the first stages of the wear process.

From these considerations, it can be concluded that the material, in respect to the standard UHMWPE, is highly resistant to oxidation phenomena, therefore it is expected to have superior in vivo endurance performance.


Franz Kralinger Christine Voigt Andreas Platz Klaus Schaser Frankie Leung Reto Babst Martin Majewski Ulrich Stöckle Kurt Käch

Introduction

A review of the literature showed a discrepancy between biomechanical and clinical studies on fracture fixation failure in patients with poor bone quality.

The objective of the present study is to assess the influence of local bone status on complications after surgical treatment of proximal humerus fractures.

Methods

A prospective cohort study was initiated in 2007. The inclusion criteria were closed displaced fractures of the proximal humerus, primary fracture treatment with a Philos plate, patients aged 50 to 90, normal pre-trauma function of both shoulders in accordance to age, and monotrauma. There was active follow-up for one year with radiological assessment at clinical centers from four countries. Bone quality at the proximal humerus was determined preoperatively for the contralateral side of the fracture by CT scan, and at the contralateral radius within six weeks post-surgery by DXA. The occurrence of complications was monitored up to one year post-surgery. Independent x-ray evaluation and final classification of all complications will be performed at the end by a study review board using anonymous data and x-rays.


Christoph Albers Willy Hofstetter Klaus Siebenrock Regine Landmann Frank Klenke

Introduction

Infection of endoprostheses is a serious complication in orthopedic surgery. As silver is known for its antibactierial effects, silver-coated endoprostheses have gained increased attention to decrease infection rates. However, cytotoxic effects of silver on bone cells have not been investigated in detail. We aimed to investigate whether silver nano-/microparticles and ionic silver exert cytotoxic effects on osteoblasts and osteoclasts in vitro and to correlate potential effects with the antibacterial effect on Staph. epidermidis.

Methods

Murine osteoclasts (OC) and murine osteoblasts (OB) were treated with silver particles (avg. sizes: 50nm, 3μm, 30μm, 8μg/ml–500μg/ml) and Ag+NO3- (0.5μg/ml–500μg/ml). Silver treatment started on day 3 to prevent interference with cell adhesion. XTT assays were performed to assess cell viability. Tartrate resistant acidic phosphatase (TRAP) activity and alkaline phosphatase (ALP) activity served as measures for OC and OB differentiation, respectively. The release of silver ions from silver particles was quantified with atomic emission spectometry (AES). Titanium particles (avg. sizes: 50nm and 30μm) were used as controls to investigate whether potential silver effects were particle- or ion-mediated. The antimicrobial activity of silver ions and particles was tested with Staph. epidermidis agar inhibition assays.


Troels Riis Henning Ogarrio Henrik Jorgensen Jes Lauritzen Susanne Van Der Mark Benn Duus

At Bispebjerg University Hospital in Denmark, an Optimized Hip Fracture Program, (OHP) is the standard of care for all hip fracture patients. Part of OHP is pain treatment with a femoral nerve catheter placed at the emergency room, dosed 4 times a day with Bupivacain until 4 days after surgery, combined with systemic analgesics as needed. In 2008, a database and a bio bank were created at the ward including all hip fracture patients to make a better description of the population and as a tool for further optimisation of the OHP. One of the aims was to identify possible subgroups having specific complications, which could lead to a differentiation of the OHP by markers known at the time of admission. In this analysis, we will focus on postoperative pain that inhibits mobilization by fracture type and type of surgery.

Methods

A consecutive cohort of 898 hip fracture patients hospitalized within two years from September 2008 to July 2010 was used for this study. Patients coming from nursing homes were excluded from the study, since nearly all are discharged 1 or 2 days after surgery to rehabilitation. If the exact type of fracture was not known, or if the patient was admitted for rehabilitation after surgery at another hospital, the patient was also excluded. 508 patients were thus included in the study. Mean age 80.0 years (SD:23.7), 72.1% women and 27.9% men.

Mobilization inhibited by postoperative pain as documented in the patient files was registered in the database. Overall mobilization was inhibited by pain in 26.7% of the 508 patients included.

The following fracture types were studied: Femoral neck Garden 1–2, Femoral neck Garden 3–4, Pertrochanteric Evans 1–2, Pertrochanteric Evans 3–5, Basocervical and Subtrochanteric.

Results

Mobilization inhibited by pain was not significantly associated with type of surgery:

Cannulated Hip Screws 16/80 (20.0%), sliding hip screw 23/94 (24.5%), Intramedullary Nail 63/186 (33.9%), partial hip replacement 33/144 (22.9%), total hip replacement 1/5 (20.0%). P = 0.09 chi square.

On the other hand mobilization inhibited by pain was significantly associated with fracture type:

Femoral neck Garden 1–2: 13/64 (20.3%), Femoral neck Garden 3–4: 38/172 (22.1%), Pertrochanteric Evans 1–2: 18/69 (26.1%), Pertrochanteric Evans 3–5: 46/149 (30.9%), Basocervical: 6/28 (21.4%), Subtrochanteric 15/27(55.6%). P = 0.009 chi square.


Matthias Gebauer Stefan Breer Michael Hahn Daniel Kendoff Michael Amling Thorsten Gehrke

Introduction

Modular tantalum augments have been introduced to manage severe bone defects in hip and knee revision surgery. The porous surfaces of tantalum augments are intended to enhance osseointegration and a number of studies have documented their excellent biocompatibility. However, the characteristics of tantalum augment osseointegration on human ex vivo specimens from re-revision procedures have not been reported so far.

Methods

Out of a total number of 324 hip and knee revisions with a tantalum augment performed in our institution between 2007 and 2010 four patients had to be re-revised at a mean followup time of 15 months. The causes for re-revision were a periprosthetic acetabular fracture in one, a loosening of a tibial component in one and periprosthetic hip infections in two cases. To characterize osseointegration of the tantalum augments, they were removed during revision surgery and subjected to undecalcified processing. All specimens were analysed by contact radiography, histology (toluidine blue, von Kossa) and quantitative histomorphometry.


Petr Nesnidal Jan Stulik Jan Kryl Michal Barna

INTRODUCTION

Spinal injuries in children are rare and account for a low proportion of all childhood injuries. Because of higher mobility and elasticity of the spine and a lower body mass in children, spinal injuries are not frequent and represent only 2 to 5 % of all spinal injuries.

MATERIAL

All patients from birth to the completed 18th year of age treated in our departments between 1996 and 2005 were included in this study. The patients, evaluated in three age categories (0–9, 10–14, 15–18), were allocated to two groups according to the method of treatment used (conservative or surgical). The information on patients treated conservatively was drawn from medical records; the surgically treated patients were invited for a check-up.


Cigdem Sarac Sander Dijkstra Antonie Taminiau Marc Nieuwenhuijse Lucia Kroft Edwin Van Der Linden

Introduction

An aneurysmatic bone cyst (ABC) is a benign cystic lesion of bone composed of blood-filled spaces separated by connective septa.

The most common treatment is curettage with or without bone grafting. Curettage with bone grafting and Ethibloc injection therapy have a comparable recurrence rate. Ethibloc is a radiopaque alcohol solution of corn protein which is percutaneously injected in the ABC.

Objective

To compare percutaneous Ethibloc injection (ETHI) with curettage with bone grafting (CUBG) in the treatment of ABC.


Christian Von Rueden Oliver Trapp Christian Hierholzer Sandra Prohaska Klaus Bräun Simone Wurm Volker Buehren

Background

For the treatment of proximal humeral fractures two major therapeutic principles can be employed: Intramedullary nailing (PHN) or locking plate osteosynthesis. Aim of this study was to evaluate and compare clinical and radiological long-term outcome of proximal humeral fracture stabilization using PHN or angular stable plating. In addition, we discussed advantages and disadvantages of both techniques and aimed at establishing criteria which operative technique should preferentially be utilized for selected fracture configurations.

Materials and Methods

In a prospective study between 2003 and 2010 we analyzed 72 patients with proximal humeral fracture who had been treated by PHN (44 patients) or angular stable plating (28 patients) in a European Level 1 Trauma Center. In the two cohort groups the following epidemiologic data was found. 46 patients were women, and 26 men with a mean age of 60.6 years (range 18–91). Follow-up was performed 38–82 months after accident, on average. Mechanism of injury was fall in 59, motor cycle accident in 4, bike accident in 8 patients, and fall from horse in 1 patient. Duration time between accident and operation was 2.8 days on average. Osteoporosis was previously known in 20 out of all evaluated patients (plate: 7/28; nail: 13/44). Fractures were classified using the Neer classification and Binary description system: There were 35 3-part fractures (PHN: 26; plate: 9) and 37 4-part fractures (PHN: 18; plate: 19), respectively. Functional and radiological outcome was assessed in a range of 38–82 months after trauma using Constant Score.


Thomas Repantis Panagiotis Aroukatos Vassiliki Bravou Maria Repanti Panagiotis Korovessis

Background

An increased incidence of periprosthetic osteolysis, resulting in loss of biologic fixation, has been recently reported in contemporary THAs with low-carbide metal-on-metal compared to metal-on-polyethylene couple bearings. A hypersensitivity reaction due to Co and Cr debris is reported as a potential cause for failure of THAs with high-carbide bearings, but there are no evidence-based data for this reaction in low-carbide metal-on-metal bearings.

Questions/purposes

We investigated whether there were differences in immunologic hypersensitivity reactions in retrievals from revised THAs with COP versus MOM bearing couples.


Chloe Scott Raj Bhattacharya Deborah Macdonald Frazer Wade Richard Nutton

Unicompartmental knee replacements (UKRs) have inconsistent and variable survivorships reported in the literature. It has been suggested that many are revised for ongoing pain with no other mode of failure identified. Using a medial UKR with an all-polyethylene non-congruent tibial component from 2004–7, we noted a revision rate of 9/98 cases (9.2%) at a mean of 39 months. Subchondral sclerosis was noted under the tibial component in 3/9 revisions with well fixed implants, and the aim of this study was to investigate this as a mode of failure. 89 UKRs in 77 patients were investigated radiographically (at mean 50 months) and with SF-12 and Oxford Knee scores at mean follow up 55 months. Subjectively 23/89 cases (25%) had sclerosis under the tibial component. We describe a method of quantifying this sclerosis as a greyscale ratio (GSR), which was significantly correlated with presence/absence of sclerosis (p<0.001). Significant predictors of elevated GSR (increasing sclerosis) were female sex (p<0.001) and elevated BMI (P=0.010) on both univariate and multivariate analysis. In turn, elevated GSR was significantly associated with poorer improvement in OKS (p<0.05) at the time of final follow up. We hypothesise that this sclerosis results from repetitive microfracture and adaptive remodelling in the proximal tibia due to increased strain. Finite element analysis is required to investigate this further, but we suggest caution should be employed when considering all polyethylene UKR implants in older women and in those with BMI >35.


Saqeb Mirza Simon Tilley Alexander Aarvold Madeleine Sampson David Culliford Douglas Dunlop

Introduction

Controversy exists as to whether the short external rotator tendons and capsule of the hip should be repaired after posterior approach primary total hip arthroplasty (THA). Recent studies using radiopaque markers have demonstrated that reimplantation of these muscle tendons fail early and may not prevent post operative dislocation.

Methods

Using dynamic ultrasound examination we evaluated the patency of repair in 68 tendon groups (piriformis/conjoint tendon and obturator externus). We demonstrate short and medium term success in the reimplantation of these tendons using the double transosseous drill hole technique of reattaching the tendons and capsule to the greater trochanter. We followed up 21 of our total hip replacements and 13 hip resurfacings and undertook a dynamic ultrasound examination of the external rotators by an experienced musculoskeletal radiologist to assess their integrity at a minimum of 60 days and 100 days and an average of 213 days after the operation.


Christian Wirtz Falko Herold Ariane Gerber Popp

OBJECTIVES

In elderly patients the temporary loss of function of the upper extremity due to immobilization for treatment of unstable proximal humeral fractures is a very disabling condition. Stable fixation of such fractures allowing immediate functional aftercare may contribute to early social reintegration in this group of patients. Aim of this study is to present the surgical technique of humeral blade plate fixation and the clinical and radiographic results after fixation of unstable surgical neck fractures with this implant followed by immediate functional treatment in patients older than 60 years.

PATIENTS

20 patients (4 male, 16 female) with a mean age of 74 years (59y–93y) were included in this study and treated consecutively for an unstable/displaced surgical neck fracture with a humeral blade plate. Postoperatively functional treatment was allowed. All but one patient had a clinical and radiographic follow-up 6 weeks po. At an average final follow-up of 18,8 months (12–24 months) 4 patients had died from causes unrelated to surgery.


Farshad Adib Derek Ochiai Skye Donovan

Introduction

Acetabular labral pathology is now recognized as a more common injury than previously thought. With cost constraints of MRI and invasiveness of MRI arthrogram, physical examination remains essential for diagnosis. Most tests for labral pathology are currently done in the supine position. We have developed the “twist test,” which is done with the patient standing and can evaluate the patient in functional, weight bearing position. The purpose of this study is to describe the twist test and compare its reliability to MRI arthrogram.

Material and methods

Between June 2009 and August 2010, the twist test was performed on all patients presenting to our clinic with complaint of hip pain. 371 patients had the twist test performed. Of these, 247 had an MRI arthrogram (MRA) of the affected hip. The twist test results were compared with MRA findings. A labral tear, degeneration, fraying and paralabral cyst were considered as a positive MRA.

The twist test is done with the patient facing the examiner, toes pointing forward. The patient bends their knees to 30 degrees and performs a windshield wiper like action with maximal excursion to the left and right. If the patient tolerates this, then the patient first gets on the unaffected leg, again with the knee bent at 30 degrees, and “does the twist” one-legged, with the examiner holding their hands gently for balance. The test is then repeated on the affected hip. A positive test is groin pain on the affected hip, apprehension with performing the test on the affected hip, or gross range of motion deficits on the affected hip compared with the unaffected side.


Jan Christoph Katthagen Christine Voigt Gunnar Jensen Helmut Lill

Implant removal is necessary in up to 25% of patients with plate osteosynthesis after proximal humeral fracture. Our new technique of arthroscopic implant removal offers all advantages of minimal invasive surgery. Additionally treatment of concomitant intraarticular lesions is possible. This study outlines the first results after arthroscopic implant removal in comparison with those of open implant removal.

A prospective series of 40 consecutive treated patients had implant removal and arthrolysis after plate osteosynthesis of proximal humeral fracture. Implant removal was carried out due to limitation in range of movement, secondary implant dislocation and implant impingement. 30 patients (median age 63 (30–82) years) had arthroscopic, ten patients (median age 53 (34–76) years) had open implant removal. Median 10 months after implant removal subjective patient satisfaction, Constant Murley Score (CMS) and Simple Shoulder Test were determined.

Arthroscopic implant removal showed comparable first results as open implant removal. There was no significant difference between CMS of both groups. The active shoulder abduction, flexion and external rotation improved significantly after arthroscopic and open implant removal. The simple shoulder test outlined advantages for the arthroscopic technique. After arthroscopic implant removal patients showed higher subjective satisfaction as well as faster pain reduction and mobilization. Analysis of perioperative data showed less blood loss in the group with arthroscopic implant removal. In 85% of patients with arthroscopic implant removal concomitant intraarticular lesions were observed and treated.

The arthroscopic implant removal after plate osteosynthesis of proximal humeral fractures offers all advantages of minimal invasive surgery and comparable first results as the open implant removal. The subjective and objective satisfaction of patients is high. The technique can be applied and established by all arthroscopic trained shoulder surgeons.


Dariush Savadkoohi Babak Siavashi Mohammad Savadkoohi

Background

Fibrous dysplasia is a developmental anomaly of bone formation that may exist in a monostotic or polystotic form. Surgical treatment is considered advisable only with presence of significant or progressive deformity or persistent pain. Early surgery is indicated before the tumor expands or fracture occurs.

Methods

We reviewed a series of 21 patients, 14 had monostotic whereas 7 had polystotic fibrous dysplasia. There was no case of Mc Cune Albright. We treated all of these patients with curettage and corticocancellous bone graft and also fixation with reconstruction nails. Follow up ranged between 1 and 5 years. Functional and radiographic outcomes were scored.


Johan Keurentjes Marta Fiocco Bw Schreurs Bart Pijls Klaas-Auke Nouta Rob Nelissen

Introduction

The Kaplan Meier estimator is widely used in orthopedics. In situations where another event prevents the occurrence of the event of interest, the Kaplan Meier estimator is not appropriate and a competing risks model has to be applied. We questioned how much bias is introduced by erroneous use of the Kaplan Meier estimator instead of a competing risks model in a hip revision surgery cohort.

Methods

In our previously published cohort study, 62 acetabular revisions (58 patients) were performed between January 1979 and March 1986. Twenty to twenty-five years after surgery, no patients were lost to follow-up. Thirteen patients underwent revision surgery. During the 20 to 25 years follow-up, 30 patients (33 acetabular revisions) died of causes unrelated to their hip surgery.


Panayiotis Christofilopoulos Anne Lübbeke Charles Berton Alexandre Lädermann Martin Berli Constantinos Roussos Robin Peter Pierre Hoffmeyer

Introduction

Large diameter metal on metal cups have been used in total hip arthroplasty advocating superior results with respect to dislocation rates, range of motion and long term survival. The Durom cup used as part of the Durom hip resurfacing system has been incriminated with poor short term results sometimes correlated to incorrect positioning of either the femoral or acetabular component. Our objective was to evaluate short term results of the Durom cup used in conjunction with standard stems.

Methods

We prospectively followed all patients with a large diameter metal-on-metal articulation (Durom) and a standard stem operated upon between 9/2004 and 9/2008. Patients were seen at follow-up for a clinical (Harris hip score=HHS, UCLA scale and patient satisfaction), radiographic and questionnaire assessment.


Yu Wang Cody Bunger Ebbe Hansen Kristian Hoy Chunsen Wu

Objective

To identify risk factors for the presence of distal adding-on in Lenke 1A scoliosis and compare different treatment strategies.

Summary of Background Data

Distal adding-on is often accompanied by unsatisfactory clinical outcome and high risk of reoperation. However, very few studies have focused on distal adding-on and its attendant risk factors and optimal treatment strategies remain controversial.


Thomas Ilchmann Silke Pannhorst Anne Mertens Martin Clauss

Introduction

The usefulness of minimal invasive hip replacement is frequently discussed but there is a lack of data on the effect of the surgical approach on early results. We wanted to study the effect of the surgical approach on the peri- and early postoperative outcome.

Material/Methods

In a prospective case control study 315 elective hip replacements were performed between January 2008 and March 2010. Until March 2009 a lateral transgluteal approach (STD) was used, then the approach was changed to a minimal invasive anterior approach (MIS). All operations were performed in the same routine setting not affected by the approach. Duration of operation, complications and bloodloss were assessed. 1 week postoperatively, independent mobility, stairs, central analgetics were analysed and length of stay was recorded. At 6 and 12 weeks, pain and patients satisfaction (VAS) and the Harris Hip Score were assessed.

Pre- and postoperative radiographs were compared for component position and orientation (EBRA).


Alexander Auffarth Nicholas Matis Stefan Lederer Stefanie Karpik Heiko Koller Wolfgang Hitzl Herbert Resch

Introduction

Depending on patient's age, risk factors and pretraumatic mobility, a total- or hemiarthroplasty of the hip have become the treatment of choice in femoral neck fractures(1–4). Internal fixation has shown to provide minor results. The majority of these patients are therefore treated by a hemiarthroplasty of the hip. Since the primary goal is to regain the pretraumatic level of mobility as soon as possible(3;5), we sought to investigate, if a minimal invasive anterior approach would be beneficial in regard of perioperative blood loss(6), postoperative pain(7;8) and thus postoperative mobility(9).

Patients and methods

In a randomised controlled trial, 48 patients were treated by a hemiarthroplasty of the hip via an anterior or lateral approach in supine position within 72 hours after trauma(10). Apart from parameters like age, ASA-Score or Body-mass-index, the main focus was set on perioperative blood loss, pain and postoperative mobilisation. All data collected were compared between groups to detect statistical significant differences. Additionally the same parameters were checked for significant differences comparing patients with or without complications within their group.


Pietro Ruggieri Elisa Pala Teresa Calabrò Carlo Romagnoli Matteo Romantini Roberto Casadei Caterina Abati Mario Mercuri

Aim

Aim of this study was to review surgical treatment of femural metastases, comparing nailing versus resection and prosthetic reconstruction.

Method

Between 1975 and 2008 110 patients were surgically treated for metastatic disease of the femur. Prostheses were implanted in 57 cases (16 HMRS® Stryker, 38 MRP® Bioimpianti, 2 Osteobridge® and 1 GMRS®). In 53 patients femoral nailing was performed with different types of locked nails (32 Gamma, 14 Grosse-Kempft and 6 T2-Stryker®). Sites of primary tumor were breast (33 cases), kidney (18), lung (17), undifferentiated carcinoma (14), g.i. (8), bladder and prostate (5 each), endometrium and thyroid (3 each), skin (2), pheochromocytoma and pancreas (1 each). Indications to nails were given in patients with femoral metastasis and poor prognosis: multiple metastases, short free interval, unfavourable histotype, poor general conditions. Resection and prosthesis was preferred for patients with solitary metastasis, long free interval, favourable histotype, good general conditions or in whenever the extent of the lesion was not amenable to a durable internal fixation. Complications were analysed. Univariate analysis by Kaplan-Meier curves of implant and oncological survival was performed. Functional results were assessed with MSTS system.


Nicolas Martinez Carranza Hilkka Nurmi-Sandh Ann-Sofie Lagerstedt Kjell Hultenby Hans Berg Leif Ryd

Single focal grade IV cartilage lesion in the knee has a poor healing capacity. Instead these lesions often progress to severe and generalized osteoarthritis that may result in total knee replacement. Current treatment modalities aim at biological repair and, although theoretically appealing, the newly formed tissue is at the best cartilage-like, often fibrous or fibrocartilaginous. This at the expense of sophisticated laboratory resources, delicate surgery and strict compliance from patients.

An alternative may be small implants of biomaterial inserted to replace the damaged cartilage. We investigated the response of the opposing tibia cartilage to a metallic implant inserted at different depth into the surrounding cartilage level.

Methods

The medial femoral condyle of both knees of 12 sheep, 70–90kg, 2 year of age and from the same breeder, was operated. A metallic implant with an articulating surface of 316L stainless steel, diameter of 7mm, HA plasma sprayed press-fit peg and a tailored radius and contour to the sheep femoral condyle was placed at the most weight-bearing position. The level of the implant was aimed flush, 0,3 and 0,8 mm below surrounding cartilage. The animals were stabled indoors, allowed to move freely and euthanized after 6 and 12 weeks. Postoperatively the knees were high resolution photographed for macroscopic evaluation. The position and depth of the implant were analysed using a laser scan device. Tibial and femoral condyles specimen were decalcified and slices were prepared for microscopic evaluation. Implant position and cartilage damage was assessed from two independent observers using a macroscopic ICRS score and a modified histologic score according to Mankin.

Results

22 tibia condyles showed a variety of cartilage damage ranging from severe damage down to subchondral bone to an almost pristine condition. There was a strong correlation between implant position and damage to opposing cartilage surface. Mankin score correlated significantly with implant position (p<0.001 regression analysis, r2=.45) as did the ICRS score (p<0.001, regression analysis, r2=.67). Implants sitting proud were associated with poor Mankin score. There was no difference between 6-week and 3-months knees.


Pietro Ruggieri Elisa Pala Eric Henderson Philip Funovics Francis Hornicek Reinhard Windhager Thomas Temple Douglas Letson Mario Mercuri

Introduction

The current investigation includes a retrospective review of the experience of five Institutions with distal femur megaprostheses for tumor over a twenty year period, to analyze the incidence and etiology of failure, using a new classification system based upon the failure modes.

Methods

Between 1974 and 2008, 2174 patients underwent primary limb preservation for a benign or malignant extremity tumor using a metallic megaprosthesis at five Institutions, 951 (43.7%) were distal femur replacements. Retrospective analysis of complications according to the Letson and Ruggieri Classification was performed and Kaplan-Meier curves of implant survival were defined.

Segmental megaprosthetic reconstruction failures were categorized as mechanical and non-mechanical failures.


Rohit Dhawan Vikas Sharma

Aims

The aim of this study was to statistically analyse the incidence and distribution of humerus fractures in the adult age group between 3rd and 10th decades.

Methods

The total number of patients was retrieved from the audit department of the hospital using the codes to identify patients between 1997 and 2009. The data included total number of patients aged 20 to 100 years who were either reviewed in the fracture clinics or admitted to the hospital with forearm fractures along with patient gender, age at the time of incident and time of the year the incident occurred. Annual incidence of fractures along with the distribution of fracture incidence per year and per individual month was calculated. The patients’ age were classified in to 3rd to 10th decades. Linear regression analysis was carried out to identify the relationship between fracture incidence and the age or time of the injury. Correlation coefficients(R) and r2 were calculated for all the regression analyses. SPSS (version 16) and Microsoft Excel 2007 were used for statistics.


Fabian Von Knoch Carl Neuerburg Franco Impellizzeri Joerg Goldhahn Philipp Frey Florian Naal Marius Von Knoch Michael Leunig

Background

Second-generation high-carbon CoCrMo-alloy metal-on-metal total hip arthroplasty (THA) was introduced in the late 1980s following reports of early loosening, impingement, pronounced wear, and hypersensitivity in the first-generation metal-on-metal articulations. There has been inconsistent data that specifically addresses the clinical performance and longevity of second-generation metal-on-metal THA. The purpose of this study was to evaluate the survival of second-generation metal-on-metal primary THA and to assess the influence of demographic factors on implant survival in a large patient cohort.

Methods

One thousand two hundred and seventy second-generation 28 mm metal-on-metal primary THA in 1121 patients were performed at one institution from 1994 to 2004. According to the International Documentation and Evaluation System patients were followed routinely at one year, two years and every five years thereafter. Clinical and radiographic outcome data was prospectively recorded using a hospital joint registry. At a mean follow-up of 6.8 years postoperatively, the probability of survival of THA was estimated using the method of Kaplan and Meier. Relative risk factors for implant failure that included age, gender, BMI, type of implant fixation and size of implant components were calculated using the Cox proportional-hazards model.


Pietro Ruggieri Andreas Mavrogenis Giuseppe Rossi Eugenio Rimondi Andrea Angelini Giuseppe Ussia Mario Mercuri

Aim

To present selective arterial embolization with N-2-butyl Cyanoacrylate for the palliative and/or adjuvant treatment of painful bone metastases not primarily amenable to surgery.

Material and Methods

From January 2003 to December 2009, 243 patients (148 men and 95 women; age range, 20–87 years) with painful bone metastases were treated with N-2-butyl Cyanoacrylate. Overall, 309 embolizations were performed; 56 patients had more than one embolization. Embolizations were performed in the pelvis (168 procedures), in the spine (83 procedures), in the upper limb (13 procedures), in the lower limb (38 procedures) and in the thoracic cage (21 procedures). Primary cancer included urogenital, breast, gastrointestinal, thyroid, lung, musculoskeletal, skin, nerve and unknown origin. Renal cell carcinoma was the most commonly treated tumor. In all patients, selective embolization was performed by transfemoral catheterization.


Pietro Ruggieri Teresa Calabrò Juan David Valencia Andreas Mavrogenis Matteo Romantini Giovanni Guerra Mario Mercuri

Aim

Bone metastases of the upper limb are a frequent complication of primary tumors. The aim of this study is to evaluate treatment and functional results of patients with prosthetic reconstruction of the proximal humerus.

Method

Between 1975 and 2007, 67 patients were treated by resection of humeral metastasis and reconstruction with prosthesis. Cemented modular prostheses of the proximal humerus were implanted in 59 cases (all MRS Bioimpianti® prostheses), uncemented prostheses in 2 (HMRS® Stryker), 4 elbow Coonrad-Morrey prostheses (in 2 cases with bone allograft), 1 elbow custom-made cemented and 1 intercalary prosthesis (Osteobridge Merete®).

Sites of primary tumors: kidney (23), lung (13), bone and unknow (7 each), liver and breast (3 each), bladder, endometrium, thyroid, soft tissues and nervous tissues (2 each), ovarium (1).

Complications were evaluated and univariate analysis with actuarial Kaplan-Meier curves of implant survival was performed. Functional results were assessed with the MSTS system.


Gulraj Matharu Andrew Thomas Paul Pynsent

Introduction

Direct lateral approaches to the hip require detachment and repair of the anterior part of the gluteus medius and minimus tendon attachments. Limping may occur postoperatively due to nerve injury or failure of muscle re-attachment. The aim of this study was to assess the integrity of abductor muscle repairs using a braided wire suture marker.

Methods

Total hip arthroplasties were inserted using a modified Freeman approach. After repair of the abductor tendons using a 1 PDS suture with interlocking Kessler stitches, a 3–0 braided wire suture marker was stitched into the lower end of the flap. The suture was easily visible on postoperative radiographs and its movement could be measured. Patients were assessed using radiographs and Oxford hip scores collected prospectively.


Gulraj Matharu Curtis Robb Khalid Baloch Paul Pynsent

Background

Unicompartmental knee arthroplasty provides a good alternative to total knee arthroplasty in patients with isolated medial compartment osteoarthritis. There has been variable reporting in the literature as to whether age and sex affect the survival of unicompartmental knee arthroplasty. The aim of this study was to determine whether age and sex were predictors of failure for the Oxford unicompartmental knee arthroplasty.

Methods

Details of consecutive patients undergoing Oxford unicompartmental knee arthroplasty at our centre between January 2000 and December 2009 were collected prospectively. Failure of the implant was defined as conversion to total knee arthroplasty. Survival was determined using the Kaplan-Meier method. A Cox proportional hazard model was used to determine the affect of age and sex on survivorship of the prosthesis.


Gulraj Matharu Curtis Robb Khalid Baloch Paul Pynsent

Background

A number of studies have reported on the early failure of the Oxford unicompartmental knee arthroplasty. However, less evidence is available regarding the outcome following revision of failed unicompartmental knee prostheses to total knee arthroplasty. The aims of this study were to determine the time to failure for the Oxford unicompartmental knee arthroplasty and to assess the short-term outcome following revision surgery.

Methods

Details of consecutive patients undergoing revision of an Oxford unicompartmental knee arthroplasty to a total knee arthroplasty at our centre between January 2000 and December 2009 were collected prospectively. Data was collected on patient demographics, indication for revision surgery, and time to revision from the index procedure. Clinical and radiological outcome following revision arthroplasty was also assessed.


Yves Tourne Christian Mabit Jean-Luc Besse Francois Bonnel Eric Toullec

The present study sought to assess the clinical and radiological results and long-term joint impact of different techniques of lateral ankle ligament reconstruction.

Material and methods

A multicenter retrospective review was performed on 310 lateral ankle reconstructions, with a mean 13 years’ follow-up (minimum FU of 5 years with a maximum of 30). Male subjects (53%) and sports trauma (78%) predominated. Mean duration of instability was 92 months; mean age at surgery was 28 years. 28% of cases showed subtalar joint involvement. Four classes of surgical technique were distinguished: C1, direct capsulo-ligamentary repair; C2, augmented repair; C3, ligamentoplasty using part of the peroneus brevis tendon; and C4, ligamentoplasty using the whole peroneus brevis tendon. Clinical and functional assessment used Karlsson and Good-Jones-Livingstone scores; radiologic assessment combined centered AP and lateral views, hindfoot weight-bearing Méary views and dynamic views (manual technique, TelosR or self-imposed varus).

Results

The majority of results (92%) were satisfactory. The mean Karlsson score of 90 [19–100] (i.e., 87% good and very good results) correlated with the subjective assessment, and did not evolve over time. Postoperative complications (20%), particularly when neurologic, were associated with poorer results. Control X-ray confirmed the very minor progression in osteoarthritis (2 %), with improved stability (88%); there was, however, no correlation between functional result and residual laxity on X-ray. Unstable and painful ankles showed poorer clinical results and more secondary osteoarthritis. Analysis by class of technique found poorer results in C4-type plasties and poorer control of laxity on X-ray in C1-type tension restoration.


José Fraga Fraga Ferreira Rui Cerqueira Sofia Viçoso Tiago Barbosa João Oliveira António Moreira

Triple arthrodesis is the most effective treatment resource for restoring shape and stability to the hind-foot. It is used in order to achieve a plantigrade foot, aligned, stable and painless, in the treatment of various pathologies. However, it has the effect of changing the dynamic mobility of the foot and diminishes the adapting ability to uneven ground, influencing the outcome. Opinions differ on the necessity of internal fixation to maintain the proper alignment of the hind-foot and improve consolidation, influencing the results.

The authors reviewed the patients who underwent triple arthrodesis between 01/01/1998 and 31/12/2008. Of a total of 46 patients 28 were reviewed, corresponding to 29 feet that underwent 36 interventions (7 recurrences).

Patients were divided into two groups according to whether or not the placement of internal fixation. They were evaluated according to the AOFAS ankle and hindfoot score and correlated with the radiologic result.

The most frequent indications for surgery were osteoarthrosis of the tarsus and sequelae of fractures of the calcaneus.

In the group without fixation 68% had radiological signs of consolidation. 24% required revision for non consolidation. In the group with internal fixation there was 72.7% consolidation and 9.1% required revision surgery. Bone graft was more often used in internal fixation group (72.7% vs 40%).

Group without fixation vs group with internal fixation:

AOFAS mean score: 74.5% vs 61.6%, patients without pain: 50% vs 20%; plantigrade foot with good alignment: 66.7% vs 40% without pain: 50% vs 20%; tibiotarsal arthritis: 48% vs 63.6%; Lisfranc arthrosis: 44% vs 63.6%.

There is a higher rate of consolidation in the group setting. However, the functional outcome seems to be better in the group without fixation.

Fixation seems to be associated with better consolidation. The functional outcome is related to a plantigrade and well aligned foot.


Matthijs Lipperts Bernd Grimm Wim Van Asten Rachel Senden Simon Van Laarhoven Ide Heyligers

Introduction

In orthopaedics, clinical outcome assessment (COA) is still mostly performed by questionnaires which suffer from subjectivity, a ceiling effect and pain dominance. Real life activity monitoring (AM) holds the promise to become the new standard in COA with small light weight and easy to use accelerometers. More and more activities can be identified by algorithms based on accelerometry. The identification of stair climbing for instance is important to assess the participation of patients in normal life after an orthopaedic procedure. In this study we validated a custom made algorithm to distinguish normal gait, ascending and descending stairs on a step by step basis.

Methods

A small, lightweight 3D-accelerometer taped to the lateral side of the affected (patients) or non-dominant (healthy subjects) upper leg served as the activity monitor. 13 Subjects (9 patients, 4 healthy) walked a few steps before descending a flight stairs (20 steps with a 180o turn in the middle), walked some steps more, turned around and ascended the same stairs. Templates (up, down and level) were obtained by averaging and stretching the vertical acceleration in the 4 healthy subjects. Classification parameters (low pass (0.4 Hz) horizontal (front-back) acceleration and the Euclidian distance between the vertical acceleration and each template) were obtained for each step. Accuracy is given by the percentage of correctly classified steps.


Simon Van Laarhoven Stijn Bolink Ide Heyligers Bernd Grimm

Introduction

Our classic outcome scores increasingly fail to distinguish interventions or to reflect rising patient demands. Scores are subjective, have a low ceiling and score pain rather than function. Objective functional assessment tools for routine clinical use are required. This study validates inertial sensor motion analysis (IMA) by differentiating patients with knee versus hip osteoarthritis in a block-step test.

Methods

Step up and down from a block (h=20cm, 3 repetitions) loading the affected (A) and unaffected (UA) leg was measured in n=59 subjects using a small inertial sensor (3D gyro and accelerometer, m=39g) attached onto the sacrum. Patients indicated for either primary unilateral THA (n=20; m/f=4/6, age=69.4yrs ±9.8) or TKA (n=16;m/f=7/9;age=67.8yrs ±8.2) were compared to healthy controls (n=23;m/f=13/10;age=61.7yrs ±6.2) and between each other to validate the test's capacity for diagnostics and as an outcome measure.

The motion parameters derived (semi-) automatically in Matlab for both legs were: front-back (FB-) sway and left-right (LR-) sway (up and down); peak-to-peak accelerations (Acc) during step down. In addition the asymmetry between both legs (ASS) was calculated for each parameter. Group differences were tested (t-test) and the diagnostic value determined by the area under the curve (AUC) of the ROC-curve.


Sandro Giannini Francesca Vannini Roberto Buda Marco Cavallo Alberto Ruffilli Brunella Grigolo

INTRODUCTION

Fresh bipolar shell osteochondral allograft (FBOA) is a controversial treatment option for post-traumatic ankle arthritis. Immunological response to transplanted cartilage may play a role in failure. Aim of the study is to compare two groups of patients who received FBOA in association or not to immunosuppressive therapy.

METHODS

2 groups, of 20 patients each, underwent FBOA. Only one group (group-B) received immunosuppressive therapy. Pre-operative and follow-up evaluation were clinical (AOFAS) and radiographical (X-Rays, CT- scan, MRI). Bioptic samples harvested during II look were examined by histochemical, immunohistochemical (ICRS II score) and by genetic typing analyses.


Sandro Giannini Roberto Buda Francesco Di Caprio Cavallo Marco Alberto Ruffilli Francesca Vannini

ACL (anterior cruciate ligament) partial tears include various types of lesions, and an high rate of these lesions evolve into complete tears. Most of the techniques described in literature for the surgical treatment of chronic partial ACL tears, don't spare the intact portion of the ligament. Aim of this study was to perform a prospective analysis of the results obtained by augmentation surgery using gracilis and semitendinosus tendons to treat partial sub-acute lesions of the ACL. This technique requires an “over the top” femoral passage, which enables salvage and strengthening of the intact bundle of ACL. The study included 97 patients treated consecutively at our Institute from 1993 to 2004 with a mean injury-surgery interval of 23 weeks (12–39). Patients were followed up by clinical and instrumental assessment criteria at 3 months, 1 year and 5 years after surgery. Clinical assessment was performed with the IKDC form. Subjective and functional parameters were assessed by the Tegner activity scale. Instrumental evaluation was done using the KT-2000 instrument: the 30 pound passive test and the manual maximum displacement test were performed. We obtained good to excellent results in 95.9% of cases. We didn't observed recurrences in ligamentous laxity. We believe that the described technique has the advantage of being little invasive, compatible with the ACL anatomy, and enables very rapid functional recovery and return to sport.


Francesco Benazzo Giulia Gastaldi Jacopo Fontana Matteo Marullo

Engineered bone tissue to recreate the continuity of damaged skeletal segments is one of the field of interest of tissue engineering. Trabecular titanium has very good mechanical properties and high in vitro and in vivo biocompatibility: it can be used in biomedical applications to promote osteointegration demonstrating that it can be successfully used for regenerative medicine in orthopaedic surgery (1). Purpose of this investigation was to evaluate the behavior of adipose tissue derived stem cells (hASCs) cultured on scaffolds of Trabecular TitaniumTM (Lima-Lto) (TT). hASCs are considered to be multipotent mesenchymal stem cells that are easily induced to differentiate into functional osteoblasts both in vitro and in vivo (2).

The hASCs were obtained from the subcutaneous adipose tissue of healthy donors during total hip replacement procedures after digestion with collagenase. They were seeded on monolayer and on the TT scaffolds, and incubated at 37 degrees C in 5% CO2 with osteogenic medium or control medium. The expression of bone-related genes using RT-PCR, time course of alkaline phosphatase activity and morphological investigation with Scanning Electron Microscopy (SEM) were performed to evaluate the osteogenic differentiation of hASCs. Alkaline phosphatase activity, marker of the differentiation toward the osteogenic pattern, was significantly higher in hASCs grown with osteogenic medium than in cells grown with control medium, both in monolayer and TT scaffolds; moreover, also alkaline phosphatase of hASCs grown on TT scaffolds in the presence of control medium increased with time, differently from that of cells grown on monolayer. The osteogenic differentiated hASCs expressed the bone-related genes type I collagen, osteocalcin, Runx-2 and alkaline phosphatase. SEM observations showed that hASCs differentiated toward osteoblast-like cells: they produced a big amount of extracellular matrix that covered the surface of the porous scaffolds with bridges between the pore walls. These data suggest that hASCs are able to adhere to TT scaffolds, to acquire an osteoblastic phenotype and to produce abundant extracellular matrix, with but also without osteogenic medium. We can therefore conclude that this material carries osteinductive properties being responsible of ostegenic differentiation; consequently, this scaffold/cells construct is effective to regenerate damaged tissue and to restore the function of bone tissue.


Elizaveta Kon Francesca Vannini Maurilio Marcacci Roberto Buda Giuseppe Filardo Marco Cavallo Alberto Ruffilli Sandro Giannini

Osteocondritis dissecans (OCD) is a relatively common cause of knee pain. Ideal treatment is still controversial. Aim of this exhibit is to describe the outcomes of 5 different surgical techniques in a series of 63 patients.

63patients (age 22.5±7.4 years) affected by OCD of the femoral condyle (45 medial and 17 lateral) were treated by either osteochondral autologous transplantation, autologous chondrocyte implantation with bone graft, biomimetic nanostructured osteochondral scaffold (Maioregen) implantation, bone-cartilage paste graft or bone marrow derived cells transplantation “one-step” technique. Patient evaluation included IKDC score, eq-vas score, X-Rays and MRI preoperatively and at follow-up.

Global mean IKDC improved from pre-operative 40.1±14.6 to 77.2±21.3 (p<0.0005) at mean 5.3±4.7 years follow-up, while eq-vas improved from 51.7±17.0 to 83.5±18.3(p<0.0005). No influence of age, size of the lesion, length of follow-up and associated surgeries on the result was found. No differences were found between the results obtained with different surgeries except a slight tendency of better improvement in the result following autologous chondrocyte implantation (p<0.01). Control MRI evidenced a satisfactory repair of cartilaginous layer and subchondral bone.

The techniques described were effective in providing good clinical and radiographic results in the treatment of OCD and confirmed the validity of autologous chondrocyte implantation over time. Newer techniques such as Maioregen implantation and “one-step” base on different rationales, the first relying on the characteristics of the scaffold and the second on the regenerative potential of mesenchymal cells. Both of them have the advantages to be minimally invasive surgeries and to require a single operation.


Sandro Giannini Roberto Buda Marco Cavallo Alberto Ruffilli Francesca Vannini

Introduction

Multiple ACL revisions represent an extremely demanding surgery, due to the presence of enlarged or malpositioned tunnels, hardware, injuries to the secondary stabilizers and difficulties in retrieving autologous tendons. An anatomical ACL reconstruction is not always possible. We analyzed the results in a series of patients operated with over the top reconstruction (OTTR) and lateral extra-articular plasty to the Gerdy's tubercle (LP) using Achilles (AT) or tibialis posterior tendon (TPT) allografts.

Methods

From 2002 to 2008, twenty-four male athletes with a mean age of 30.8 years were operated. 20 of the patients had two, while four patients had three previous reconstructions. IKDC score and KT evaluation were used at a mean 3.3 years follow-up (2–7 years).


Sophie Williams Graham Isaac John Fisher

INTRODUCTION

Ceramic-on-metal hip replacements (COM, where the head is a Biolox Delta ceramic and liner is Co Cr alloy), have demonstrated reduced wear under standard conditions in vitro compared to metal-on-metal (MOM) [1]. Early clinical results are also encouraging [2]. Recently concerns have been raised regarding the poor clinical performance of MOM hip resurfacings [3], particularly when cups are steeply inclined. Laboratory hip simulator testing has been used to replicate edge loading, also demonstrating elevated wear [4]. Therefore, a range of conditions to replicate sub-optimal use clinically to better predict in vivo performance should be used. The aim of this study was to compare the wear rates of MOM and COM under adverse edge loading conditions in an in vitro hip simulator test.

METHODS

Ceramic-on-metal (n=3) and metal-on-metal (n=3) 36mm hip prostheses (supplied by DePuy International Ltd, UK) were tested in the Leeds Physiological Anatomical Hip Joint Simulator. Liners were mounted to provide a clinical angle of 45o, and stems positioned anatomically. A simplified gait cycle and microseparation was applied as previously described [5] for two million cycles in 25% new born calf serum. Gravimetric analysis was completed every million cycles and wear volumes calculated.


Declan Devine Daniel Arens Silvia Burelli Hans Rudolf Bloch Ludovic Boure

The osteointegration of a new three-dimensional reticular titanium material, Trabecular Titanium™, was assessed using a bilateral cancellous (distal femur, proximal tibia) and cortical (tibia diaphysis) bone drill hole model in 18 sheep. TT is a novel Ti6Al4V material characterized by a high open porosity and composed of multi-planar regular hexagonal cells. Two 5.0 mm diameter, 12 mm long cylinders (TT1 & TT2) of two different porosities (TT1:650 μm, TT2:1250 μm) were tested and compared to two solid predicate 5.0 mm diameter, 12 mm long Ti cylinders (PT1 & PT2) coated with porous Ti (PT1: vacuum-plasma spray coating; PT2: inert-gas shielding arc spray coating).

Each implant type was surgically implanted at 4 separate locations in each sheep (16 implants per sheep). Three timepoints of 4, 16 and 52 weeks (n=6 sheep per timepoint) were used. Bone-implant interface was analyzed ex vivo by the determination of: 1) the shear strength (SS) measured during a push out test, 2) the percentage of bone in-growth (%B) using histomorphometry, 3) the bone apposition rate using fluorochrome labelling analysis and 4) the bone-implant contact using backscattered scanning electron microscopy (SEM). An ANOVA with a Bonferroni Post hoc test were used to detect differences between tested and predicate implants. P values 0.05 were considered significant.

At 4 weeks, 5 out of the 6 TT1 could be pushed out of the cortical bone (COB) samples. The remaining TT1 collapsed during testing. All TT1 could be pushed of the cancellous bone (CAB) samples. Four out of the 6 TT2 could be pushed out of CAB and of the COB samples. At 16 and 52 weeks, only one TT1 and one TT2 could be pushed out of the bone samples, the remaining implants collapsed during testing. All the PTs were successfully pushed out at all timepoints.

The mean %B of PT1 and PT2 did not significantly increase over time. For both materials, the mean %B ranged between 1.7% and 4.4% at 4 weeks and between 5.7% and 6.5% at 52 weeks. The mean %B of TT1 significantly increased over time in both COB (10.2% at 4 weeks, 46.2% at 16 weeks, 50.5% at 52 weeks) and CAB (5.8%, 23.9%, 24.3%). Similarly, the mean %B of TT2 significantly increased over time in both COB (7.8%, 48.6%, 65%) and CAB (4.5%, 24.1%, 38.6%). Bone apposition rates for the TT implants remained superior to 2 μm/day for the entire duration of the study. SEM showed an intimate bone-implant contact for all implant types at all timepoints.

At 16 and 52 weeks, histomorphometry revealed an extensive osteointegration of the TT specimens. Bone-implant interface strength was so high for the TT implants that they could not be pushed out of the bone samples. The results of this study would indicate that the TT implants provide a good scaffold for bone in-growth.


Constantinos Roussos Anne Lübbeke Werner Koehnlein Pierre Hoffmeyer

Introduction

Orthopaedic surgeons are frequently asked to perform a revision total hip arthroplasty (THA) in patients over 80 years of age. Our objective was to evaluate the outcomes after revision THA in patients 80 years or older and compare them to a cohort of patients less than 80 years of age.

Methods

We reviewed all revision THAs performed in our institution from 3/1996 to 12/2008. We compared intra- and post-operative complications (medical and orthopaedic), mortality, clinical outcomes and patient satisfaction between the two age groups. Peri-operative information and complications were collected prospectively, and clinical outcome data were obtained both pro- and retrospectively. The Merle d'Aubigné score, Harris Hip score, general health (SF-12) and patient satisfaction (visual analog scale) were assessed.


Munzir Odeh Rabea Odeh Sadeq Al-Karmi Munzir Odeh Waleed Bakeer

Background

The aim of the study was to assess the outcome of internal fixation using two ordinary plates with autogenous bone grafting in the management of non-union of femoral shaft fractures over a period of eleven years.

Method

A retrospective study of double plating and autogenous bone grafting for un-united femoral shaft fractures performed by the two Senior Authors between 1996 and 2007. During this period, twenty-one cases were carried out. Details of preoperative, intra-operative, and postoperative findings were assessed. Postoperative follow up was recorded over a period of minimum two years.

The procedure was performed using two ordinary plates; a broad lateral and narrow anterior plates. Autogenous cancellous grafts from iliac crest were used in all of the cases, and in some, half fibulas were inserted through the medullary canal of the femur.


Carmen Zietz Andreas Fritsche Wolfram Mittelmeier Rainer Bader

The prevalent cause of implant failure after total joint replacement is aseptic loosening caused by wear debris. Improvement of the wear behaviour of the articulating bearing between the cup and femoral head is essential for increased survival rate of artificial hip joints. Cross-linking of the polyethylene (PE) material is one attempt to reduce wear particle release at the articulating surface. Various cross-linked polyethylenes (X-PE) are used in orthopaedics since several years.

In total hip arthroplasty (THA) the use of larger femoral head sizes has specific reasons. Larger heads lead to a decreased risk of total hip dislocation and impingement as well as an improved range of motion in comparison to smaller head sizes like 28mm or less. However, the increasing diameter of femoral head can be associated with lower thickness of the PE liner and increased wear rate. Cross-linking of PE can improve the wear rate of the liner and hence supports the use of larger femoral heads. The aim of this experimental study was to evaluate the wear of standard vs. sequential X-PE (X3-PE) liner in combination with different ceramic femoral head sizes.

Wear testing was performed for 5 million load cycles using standard UHMW-PE liners (N2Vac) and X3-PE liners (each Stryker GmbH & Co. KG, Duisburg, Germany) combined with 28mm ceramic ball heads and the Trident PSL acetabular cup (Stryker). Furthermore, X3-PE liners with an internal diameter of 36mm and 44mm and decreased wall thickness (5.9mm and 3.8mm) were combined with corresponding ceramic heads. An eight station hip wear simulator according to ISO 14242 (EndoLab GmbH, Rosenheim, Germany) was used to carry out the standard wear tests. The tests were realised in temperature-controlled chambers at 37°C containing calf serum (protein content 20g/l).

The average gravimetrical wear rates of the standard UHMW-PE (N2Vac) liners combined with 28mm ceramic heads amounted to 12.6 ± 0.8mg/million cycles. Wear of X3-PE liners in combination with 28 mm ceramic heads was not detectable. The average gravimetrical wear rates of the X3-PE liners in combination with 36mm and 44mm ceramic heads amounted to 2.0 ± 0.5mg and 3.1 ± 0.3mg/million cycles, respectively.

The purpose of this study was to evaluate the effect of femoral head size at THA on standard and sequential X-PE liner. The wear simulator tests showed that the wear rate of PE liners with small heads (28mm) decreased by cross-linking of the PE significantly. The amount of wear at X-PE increased slightly with larger head size (36mm and 44mm). However, by sequential cross-linking, the wear rate using thinner liners and larger femoral heads is reduced to a fractional amount of wear at conventional UHMW-PE. Hence, the above-mentioned advantages of larger femoral head diameters can be realised by improved wear behaviour of sequential X-PE.


James Beazley Pedro Foguet Udai Prakash Jon Baxter Steve Krikler

Introduction

Metal on metal hip resurfacing (MMHR) has been advocated for the younger patient for several reasons including for the preservation of bone stock and ease of revision to total hip replacement (THR), thus ‘buying an additional operation’ for the patient. This rationale however assumes a good functional outcome after the revision to a THR and that the results of the ‘revision primary’ will not be compromised by the resurfacing which preceded it. We present our data on a consecutive series of 68 revised MMHRs.

Methods

Between September 1997 and September 2009, 927 consecutive patients underwent a hip resurfacing procedure performed by one of three senior surgeons at our institution. The Cormet resurfacing system was used for all patients. Sixty-eight of these patients had their resurfacing revised. Oxford hip score (OHS) obtained at a minimum of 12 months follow-up was used as the primary outcome measure.


Carmen Zietz Andreas Fritsche Regina Lange Wolfram Mittelmeier Rainer Bader

Due to increased life expectancy of human population, the amount of total knee replacements (TKR) is expected to increase. TKR reached a high grade of quality and safety, but most often it fail because of aseptic implant loosening caused by polyethylene (PE) wear debris. Wear is generated at the articulating surfaces, e.g. caused by three body particles, like bone fragments or bone cement particles. The aim of this experimental study was to compare the wear of tibial PE inserts combined with metallic and ceramic femoral components at three body wear situation induced by polymethylmethacrylate (PMMA) and zirconia (ZrO2) particles from the bone cement.

Wear testing was performed for 5 Mio load cycles, using tibial standard PE inserts combined with the same CR femoral component, in two different materials, Cobalt Chromium (CoCrMo) and Biolox delta ® ceramic (Multigen Plus Knee System, Lima Corporate, Italy). A knee wear simulator, according to ISO 14243 (EndoLab GmbH, Rosenheim, Germany), was used to carry out the tests. The tests were performed in temperature-controlled test chambers at 37 °C, containing calf serum with a protein content of 30 g/l. Polymethylmethacrylate (PMMA) and zirconia (ZrO2) bone cement particles (Palacos R ®) were manufactured to a size of 30 μm. The three body particles were added at all stations onto the articulating surface of the tibial PE insert (7mg per condyle) at every 500,000 cycles. Wear was determined gravimetrically and the surfaces of tibial inserts were analysed by scanning electron microscope (SEM) after finishing the 5 million cycles. Furthermore, roughness of the PE insert surfaces and the articulating surfaces of the different femoral components were detected and the PE wear particles were analysed by SEM.

The average gravimetrical wear rates of the tibial PE inserts in combination with CoCr and Biolox delta ® ceramic femoral components amounted to 6.4 ± 0.9 mg and 2.6 ± 0.4 mg per million cycles, respectively. Beside bone cement particles on the articulating surface of the PE inserts, polished surfaces and scratches were detected by SEM. In comparison to the untreated surfaces of the PE inserts at both material pairings the surface roughness at the articulating areas showed deep scratches and polished regions. Analyses of the metallic femoral components showed scratches at the articulating surfaces, none on ceramics.

The present study pointed out the effect of femoral component material in an abrasive three body wear situation on the wear properties of TKR. The wear simulator tests showed that wear of PE inserts under three body wear conditions, in combination with ceramic femoral components, was significantly lower than with metallic femoral components. With regard to anti-allergic properties, ceramic femoral components are promising products for TKR.


Jeevan Chandrasenan Rohan Rajan Kathryn Price

The lateral pillar classification (LPC) is a widely used tool in determining prognosis and planning treatment in patients who are in the fragmentation stage of Perthes disease. The original classification has been modified to help increase the accuracy of the classification system by the Herring group. The purpose of our study was to independently assess this modified Herring classification.

35 standardized true antero-posterior radiographs of children in various stages of fragmentation were independently assessed by 6 senior observers on 2 separate occasions (6 weeks apart). Kappa analysis was used to assess the inter and intraobserver agreement between observations made. The degrees of agreement were as follows: poor, fair, moderate, good and very good.

Intraobserver analysis revealed at best only moderate agreement for two observers. 3 observers showed fair consistency, whilst 1 remaining observer showed poor consistency between repeated observations (p<0.01). The highest scores for interobserver agreement varying between moderate to good could only be established between 2 observers. For the remaining observers results were just fair (p<0.01).

This study highlights the lack of agreement between senior clinicians when applying the modified LPC. This has clinical implications when applying the classification to the decision making process in treating patients at risk of developing adverse outcomes from the disease. To our knowledge, this is the first time the modified LPC has been independently tested for its reproducibility by another specialist paediatric orthopaedic unit.


Stephen Dalgleish Michael Reidy Brian Singer Lynda Cochrane

Introduction

New methods to reduce inpatient stay, post-operative complications and recovery time are continually being sought in surgery. Many factors affect length of hospital stay, such as, analgesia, patient and surgeon expectations, as well as provision of nursing care and physiotherapy. Development of the use of postoperative local anaesthetic infiltration delivered intra-articularly by a catheter appears to be an effective analgesic method which reduces patient's opioid requirements and allows early physiotherapy without motor blockade of muscles. Our study aimed to explore if the use of local anaesthetic infiltration intra-articularly following joint athroplasty affected the patient's duration of hospitalisation.

Methods

Looking retrospectively at arthroplasty audit data, we compared two groups of age and sex-matched patients who underwent primary hip arthroplasty (replacement and resurfacing) and knee arthroplasty performed by a single surgeon using the same surgical techniques. The surgeon began to utilize local anesthetic infiltration intra-articularly in 2009. The first group included patients operated on the year prior to the change and the second group were those operated on within a year of the change of practice. There were 103 patients (27 resurfacings, 28 knees, 48 hips) in the local anaesthetic group and 141 patients (48 resurfacings, 36 knees, 64 hips) in the non-local anaesthetic group. The length of stay was investigated for plausible Normality using the Shapiro Wilks statistic. Between-treatment group differences were examined using one-way analysis of variance (ANOVA). Factors observed were, use of local anaesthetic (yes/no), joint (hip/knee) and day of surgery (weekend/not weekend). Between treatment group differences in gender and complications were investigated using Chi-squared methods.


Daniel Kluess Daniel Kluess Ivonne Begerow Paul Goebel Wolfram Mittelmeier Rainer Bader

Introduction

Due to the commercial launch of newly developed ceramic-on-metal (COM) bearings, we compared the deformation and stresses in the liner with ceramic-on-ceramic (COC), metal-on-metal (MOM) as well as ceramic-on-polyethylene (COP) bearings using a finite-element (FE)-model, analyzing a variety of head size and implant position. Liner deformation in terms of change in inner diameter as well as peak stresses were evaluated.

Methods

The FE-model consisting of a commercial THR, the proximal femur and a section of the hemipelvis was created based on our previously published approach. Static load and muscle forces were applied according to the maximum load during gait. Polyethylene was modelled using a nonlinear definition with isotropic hardening, cobalt-chromium was modelled elastic-plastic and ceramic was modelled linear-elastic. Validity of the model was checked using an experimental setup with artificial bone and strain gauges located at the rim of the liner.

Implant material (COM vs. COC vs. MOM vs. COP), head size (28 mm vs. 36 mm) and cup position (45° inclination/15° anteversion vs. 60° incl./0° antev.) were varied.


Alexander Wood David Bell Andre Keenan Calum Arthur Charles Court-Brown

Introduction

In an ageing population the incidence of patients sustaining a neck of femur fracture is likely to rise. Whilst the neck of femur fracture is thought to be a pre-terminal event in many patients, there is little literature following this common fracture beyond 1 year. With improving healthcare and increasing survival rate, it is likely that a proportion of patients live to have subsequent fractures. However little is known about if these occur and what the epidemiology of these fractures are.

Aim

To describe the epidemiology of fractures sustained over a ten year period in patients who had an “index” neck of femur fracture.


David Barlow Elizabeth O'hagan Shetty Sanathkumar Arif Gull Ramesh Balasundaram

Background

Boxer's fractures are the most common type of metacarpal fracture. It commonly occurs during fistfights or from punching a wall. Greer et al demonstrated that it is usually an intentional injury and these patients were at increased risk for recurrent injury (2). Further work suggested that patients with such injuries had higher features of antisocial, self- harm and impulsive behavior, compared with control groups (3).

There is little that has been reported on children and adolescents who present with such fractures.

This study aims to assess aggression scores in young patients with metacarpal fractures due to punching using a validated questionnaire.

Methodology

Following ethical permission, 11–18 year olds, with a boxers fracture and willing to complete an anonymous questionnaire were included. If they were under 16, parental permission was sought. The Buss and Warren validated questionnaire included subscales of physical aggression and anger scales as well as overall aggression scoring.


Raymond Monto

Chronic plantar fasciitis is a common but sometimes difficult condition to successfully treat. Platelet rich plasma (PRP), a concentrated bioactive component of autologous blood that is rich in cytokines and other growth factors, was compared with cortisone injection in the treatment of severe cases of plantar fasciitis resistant to traditional non-operative paradigms. Thirty-six patients (16 males 20 females) were prospectively block-randomized into two study groups. All patients had pre-treatment MRI and ultrasound studies consistent with plantar fasciitis. The first group was treated with a single ultrasound guided injection of 40 mg Depo-Medrol at the injury site and the second group was treated with a single ultrasound guided injection of un-buffered autologous PRP at the injury site. The cortisone group had an average age of 59 (24–74) and had failed 4 months (3–24) of standard non-operative management (rest, heel lifts, PT, NSAIDS, cam walker immobilization, night splinting, local modalities) and had pre-treatment AOFAS scores of 52 (24–60). The PRP group had an average age of 51 (21–67) and had failed 5 months (3–26) of standard non-operative management (rest, heel lifts, PT, NSAIDS, cam walker immobilization, night splinting, local modalities) and had pre-treatment AOFAS scores of 37 (30–56). All patients were then immobilized fully weight bearing in a cam walker for 2 weeks, started on eccentric home exercises and then allowed to return to normal activities as tolerated and without support. Post-treatment AOFAS scores in the cortisone initially improved to 81(60–90) at 3 months but decreased to 74 (56–85) at 6 months. Post-treatment AOFAS scores in the PRP group improved to 95 (84–90) at 3 months and remained excellent at 94 (87–100) at 6 months follow-up. This study suggests that platelet rich plasma injection is more effective and durable than cortisone injection for the treatment of severe chronic plantar fasciitis refractory to traditional non-operative management.


Matthias Knobe Richard Sellei Philipp Kobbe Philipp Lichte Roman Pfeifer Saskia Mooij Raouff Aliyev Ralf Muenker Hans Christoph Pape

Introduction

Unstable intertrochanteric hip fractures (AO 31A2) continue to be a challenge, as non-locking implants have shown a considerable rate of loss of reduction. Intramedullary fixation has been recommended, although screw cut-out has been identified as problematic. This study was performed to ascertain whether treatments with the established proximal femoral nail (PFN) and the newer PFNA with blade design (proximal femoral nail antirotation) have advantages over the use of the Percutaneous Compression Plate (PCCP, developed by Gotfried).

Methods

Cohort study. Between March 2003 and March 2008, 134 patients with unstable fractures were treated with a PCCP, (n=44, 78.3 yrs, ASA 2.8), a PFN (n=50, 77.2 yrs, ASA 2.8), or a PFNA (n=40, 75.8 yrs, ASA 2.6). The patients (31 PCCP, 33 PFN, 30 PFNA) were then reexamined clinically and radiologically after approximately 21 months.


Paul Beaulé Craig White Jaime Lopez-Castellaro Paul Kim

Introduction

Although femoral neck fractures remain a concern in short term failures for hip resurfacing, acetabular component position and fixation are increasingly being recognized as causes of mid term failures for hip resurfacing. This study aimed to evaluate the migration pattern of a cobalt chrome, beaded acetabular component for a metal on metal hip resurfacing.

Methods

130 patients underwent metal on metal hip resurfacing: 66 hips in 60 patients had sufficient films to be included in this analysis. Forty-eight patients were male and 12 were female, with a mean age of 50 (range, 32–66). Ninety-five percent of the procedures were performed for osteoarthritis. In all cases acetabular migration was measured both vertically and horizontally, on serial radiographs using the computer-assisted Ein Bild Röntgen Analyse method. A minimum of three comparable radiographs is necessary for calculating the migration curves. We scored medial migration as negative horizontal movement.


Tomonori Shigemura Shunji Kishida Seiji Ohtori Junichi Nakamura Munenori Takeshita Makoto Takazawa Takeshi Miyasaka Yoshitada Harada Kazuhisa Takahashi

Introduction

Nociceptive and neuropathic components both contribute to chronic pain. Since these components require different pain management strategies, correct pain diagnosis before and during treatment is important.

Freynhagen et al. (2006) reported that they had developed and validated the pain-DETECT questionnaire (PD-Q) to detect neuropathic components in chronic low back pain patients. They also reported that 37% of unselected cohort of chronic LBP patients had predominantly neuropathic pain. However, the extent to which neuropathic components relate to the pathomechanism of pain deriving from osteoarthritis of hip joint remains unknown.

The purpose of this study was to utilize PD-Q to investigate the relationship between neuropathic components and pain deriving from osteoarthritis of the hip joint.

Methods

Between March and August 2010, 125 patients with osteoarthritis of hip joint completed PD-Qs about their pain. From this data set, we investigated whether or not the patients’ pain contained neuropathic components.


Issaq Ahmed Nicholas Clement Wykeat Tay Daniel Porter

Background

Fractures of the scaphoid are uncommon in the paediatric population. Despite their rarity a significant number of children are referred to the fracture clinic for a suspected scaphoid fracture. The aim of this study is to report on the incidence and pattern of injury of the paediatric scaphoid fracture and present a new classification.

Methods

An analysis of all paediatric scaphoid fractures treated in the Royal Hospital for Sick Children, Edinburgh (age up to 14 years old) over a five year period. The case notes, radiographs and were applicable MRI scan for these patients were reviewed. The clinical information recorded included the dominant hand, mechanism of injury, clinical features on examination, type of cast and length of period, stiffness following cast removal and evidence of delayed or non union. Each radiograph was analysed independently and fracture classified according to a new classification system.


Issaq Ahmed Fiona Ashton Robert Elton Christopher Robinson

Background

The functional outcome and risk of recurrence following arthroscopic stabilisation for recurrent anterior shoulder instability is poorly defined in large prospective outcome studies. This is the first study to prospectively evaluate these outcomes in patients who have been treated using this technique.

Methods

We performed a prospective study of a consecutive series of 302 patients (265 men and 37 women, mean age 26.4 years) who underwent 311 (9 bilateral) arthroscopic Bankart repairs for recurrent anterior instability. Patients were evaluated preoperatively and postoperatively at 6 months, and annually thereafter. The chief outcome measures were risk of recurrence and the two-year functional outcomes (assessed using the WOSI and DASH scores).


Thittukattoor Sudhahar Akkenna Sudheer Vidhesh Raut

Introduction

Total knee replacement has been well-established form of treatment both for osteoarthritis and inflammatory arthritis. Both cemented and uncemented TKR have been used successfully. Since 1977 low contact stress (LCS) mobile bearing knee replacement has been in extensive use. Most of the intermediate and long term results reported are in osteoarthritis1–7. Though there are several studies reporting short term performance of TKR in rheumatoid arthritis8–19 there have been rare reports31 of intermediate to long-term performance of LCS uncemented TKR in rheumatoid arthritis.

Methods

Retrospective, non-randomised and consecutive study. Case notes and radiological assessment done. Kaplan meyer survival analysis used. Radiological assessment between initial and final xrays done using T test statistics. Assessement done by two independent observer.


Robert Lawton Brian Singer David Ridley

Background

Metal on metal hip resurfacing has become popular worldwide for younger patients because of perceived advantages in function and ease of revision, due to bone conservation. Joint Registry data have shown increased risk of early failure, particularly in younger females. There have been few studies comparing the outcome of resurfacing to cemented total hip arthroplasty (THA).

Methods

715 Hip Resurfacings (HR) performed between 2000 and 2010 with up to 10 years follow-up were compared with 2210 Exeter cemented Total Hip Arthroplasties (THA) performed for all diagnoses during the same period within our region. Survivorship was recorded using revision for any cause as the end point. Harris Hip Scores were collected pre-operatively and at 1,3,5 and 7 year review. Prospective independent analysis was carried out using Kaplan Meier survivorship, and non-parametric testing to investigate the effect of age (under 55 and over 55) and gender on revision rate and Harris Hip Score.


Emmanouil Myriokefalitakis Konstantinos Papanastasopoulos Amalia Douma Thomas Krithymos Thrasivoulos Drougas John Giannoulias Konstantinos Savidis Christos Agisilaou Konstantinos Kateros

Background

The degree of postoperative pain is usually moderate to severe following Total Hip Arthroplasty (THA). Comfort and lack of pain are important for optimal mobilization and earlier home discharge.

Aim

To evaluate the efficacy and safety of Ropivacaine, a long- acting local anaesthetic, when infiltrated in the wound at the end of operation of THA.


Simon Steppacher Christoph Albers Moritz Tannast Klaus Siebenrock Reinhold Ganz

Traumatic hip dislocation is a rare injury in orthopaedic practice and typically occures in high energy trauma. The goal of this study was to analyze hip morphology in patients with low energy traumatic hip dislocations and to compare it with a control group.

We performed a retrospective comparative study. The study group included 45 patients with 45 traumatic posterior hip dislocation. Inclusion criteria were traumatic hip dislocation with simple acetabular rim or Pipkin I or II fracture. Traumatic dislocations combined with other acetabular or femoral fractures were excluded. The control group consisted of 90 patients (180 hips) that underwent radiographic examination for urogenital indication and had no history of hip pain. Hip morphology was assessed on antero-posterior and axial views.

The study group showed significantly increased incidence (p<0.001) of positive cross-over sign (82% vs. 27%) with a increased retroversion index (26 ± 17 [0–56] vs. 6 ± 12 [0–53]), positive ischial spine sign (70% vs. 34%), and positive posterior wall sign (79% vs. 21).

Hips that underwent an low energy posterior traumatic hip dislocation show significanly more radiographic signs for acetabular retroversion compared to a control group. Therefore, acetabular retroversion seems to be a contributing factor for posterior traumatic hip dislocation.


Chenxi Li Azad Hussain Joseph Pamu Amir Kamali

INTRODUCTION

Hip wear simulator test results could be affected by many non-bearing related factors such as fixation surface conditions, equipment calibration and component set-up. In an effort to improve the accuracy, reliability and repeatability of hip simulator test, a quality management system has been established at the IDC hip tribology laboratory, which has been accredited by UKAS (United Kingdom Accreditation Service) in accordance with the recognised international standard ISO17025. This study demonstrates that under well-controlled laboratory and testing conditions, satisfactory repeatability can be achieved during hip simulator studies.

METHODS

Between 2008 to 2010, ten 50 mm Birmingham Hip Resurfacing (BHR) devices were tested by the IDC tribology laboratory using two ProSim hip wear simulators in three different tests (T1, T2 and T3). All tests were performed following the same IDC testing protocols at 1 Hz frequency for 5 million cycles (Mc) or until after a steady state was reached. Paul type stance phase loadings with a maximum load of 3 kN and a swing phase load of 0.3 kN was used. The flexion and extension angles were 30 and 15 degree. The internal/external rotation angel was ±10 degree. Wear was measured gravimetrically using an analytical balance (Mettler, Toledo xp504) with an accuracy of 0.1 mg.


Lizeth Herrera Laquawn Loving Aaron Essner Jim Nevelos

Osteolysis induced by UHMWPE debris has historically been one of the major causes of long term failure of TJR. An increase in concentration of polyethylene particles in the peri-prostheic tissue has been linked to an increased incidence of osteolysis. The dual mobility hip bearing concept mates a femoral head into a polyethylene liner which has an unconstrained articulation into a metal shell. The wear mechanism of the dual mobility hip bearing is distinct from a constrained single articulation design, which may result in a difference in wear debris particles. The aim of this study is to evaluate wear debris generated from a dual mobility hip and compare it to a conventional single articulation design when both are manufactured from sequentially crosslinked and annealed polyethylene. The dual mobility hip (Restoration ADM) incorporated a 28mm CoCr femoral head into a polyethylene liner that articulates against a metal shell (48mm ID). The conventional hip (Trident®) mated a 28mm CoCr femoral head against a polyethylene liner. The polyethylene for all liners was sequentially crosslinked and annealed (X3). A hip joint simulator was used for testing at a rate of 1 Hz with cyclic Paul curve physiologic loading. A serum sample from each testing group was collected. Serum samples were protein digested following the published process by Scott et al. The digested serum was then filtered through a series of polycarbonate filter papers of decreasing size and sputter coated with gold for analysis using SEM. Image fields were randomized and wear debris was compared in terms of its length, width, aspect ration, and equivalent circular diameter (ECD). A total of 149 conventional hip particles and 114 dual mobility hip particles were imaged. Results show a majority of particles are of spherical nature and images do not indicate the presence of fibrillar or larger elongated polyethylene debris. Particle length between designs is not statistically different, while all other comparisons show statistical significance (p<0.05). It is hypothesized that the dual mobility hip system reduces the total amount of cross-shear motion on any one articulation, which aids in the reduction in wear. This design feature may be responsible for the slight difference in morphology of dual mobility wear debris when compared to the constrained hip design. The length of the particles was similar, simply indicating a different shape rather than a marked reduction in overall size. The debris generated is this study was from highly crosslinked polyethylene in two different designs, which produced a very significant decrease in quantity of particles when compared to the quantity of debris from conventional polyethylene. The wear debris was of similar length in both designs and so we do not expect any difference in biological response to debris from either device. The dual mobility design has also shown no effect of cup abduction angle on wear demonstrating forgiveness to implant positioning. This advantage, combined with the low wear rate and similar length wear particles, should lead to good clinical performance of dual mobility cups with sequentially irradiated and annealed polyethylene.


Darren Ebreo Abdul Khan Mohammed El-Meligy Catherine Armstrong Viju Peter

INTRODUCTION

The advantages of large diameter metal on metal total hip arthroplasty (MoM THA) and hip resurfacing arthroplasty are decreased wear rate, preservation of bone stock, anatomical restoration and enhanced stability. Large amounts of metal wear particles and metal ions are released which may induce adverse reactions including local soft tissue toxicity, hypersensitivity reactions, bone loss and risk of carcinogenesis. Aseptic loosening can be the result of a peri-prosthetic osteolysis generated as a result of a biological response to particulate wear debris.

No reports in the literature exist as to whether circulating levels of Chromium (Cr) and Cobalt (Co) decrease upon removal of a symptomatic large diameter MoM implant or whether levels remain high due to the effect of metal ions debris left behind in the soft tissues after revision surgery.

PATIENTS AND METHODS

Between June 2006 and June 2009 we undertook 44 revision surgeries of both large head MoM THAs (femoral head diameter 38mm) and metal-on-metal hip resurfacings for suspected metallosis. Mean time from original implant to revision was 4 years, 8 months (1yr 4mo–7yr 9mo).

The mean follow up evaluation was 2 years and 2 months (1yr 2mo–4 years). Blood samples were taken for whole blood Cr and serum Co according to a recognised protocol and compared with reference levels indicated by the Medicines and Healthcare Regulatory Agency recommendation of less than 7ppb for Cr (130nM/L) and Co (119nM/L).


Ruy Da Assuncao David Samra Peter Walker Warwick Bruce

Introduction

Pre-operative patient education prior to hip and knee arthroplasty is thought to be beneficial for patients in general, although the clinical effect is unproven. Pre-operative education is now standard practice in many orthopaedic units, including our own. Anecdotally, we found patients in the private sector to be more satisfied with their education than those in the public sector, despite very similar education programs. We set out to investigate this observation and establish whether there were differences in the perception of educational quality between these groups.

Methods

After appropriate power calculation, 60 patients in each group (120 total) were interviewed after hip or knee arthroplasty. Satisfaction with education was assessed on a simple 5 point scale and demographic data including internet access was obtained, as well as Short-Form 12 (SF-12) data to establish physical and mental function. The education program in each group was similar, with written material provided and verbal education given at a single pre-operative session. This included specialist nursing and physiotherapy input. Results were analysed with the chi2 test, Mann-Whitney U test and logistic regression as appropriate, with significance at P<0.05.


Ruy Da Assuncao Roger Haddad Warwick Bruce Peter Walker William Walsh

Introduction

In order to prepare hamstring autograft, suture fixation to the tendon is required to secure and handle the tendon during harvest and preparation. We use a simple, grasping suture which doesn't require suture of the tendon, thus saving time and avoiding violation of the graft itself. We present this technique, with results of mechanical testing compared to a standard whip suture, traditionally used to handle hamstring autograft.

Methods and materials

Twelve uniform ovine flexor tendons were prepared. A number two braided polyester suture was used in all cases. Six tendons were prepared with a standard, non-locking whip-suture, maintaining uniformity of suture bite and working length between samples. Six tendons were prepared with the utility suture, also taking care to maintain uniformity. The suture was applied by tying the thread around the tendon with a single-throw granny knot then symmetrically wrapping the suture ends from proximal to distal and securing with another single throw, allowing compression of the tendon with longitudinal tension on the suture. All the samples were tested to failure in uniaxial tension in a materials testing machine. Peak load values and load/displacement curves were acquired and results analysed with a two-sample T-test assuming significance at P<0.05.


Jan Vaculik Martin Horak Tomas Malkus Marek Majernicek Pavel Dungl Ales Podskubka

Unstable intertrochanteric fractures may be treated by several types of implants, most frequently by dynamic sliding hip screw or some form of intramedullary implant. Intramedullary implants began to be used in cases with an expectation of further improvement of osteosynthesis stability. A need to determine the advantages of single implants for selected types of fractures in randomized trials was defined. In addition to biomechanical principles, bone quality is considered, together with increasing possibilities in recent years of further improving density measurements, especially qCT with respect to local specificity. A series of 86 patients (24 men, 62 women, average age 77,6 years) was operated on from September 6, 2005 to June 30, 2009 for unstable intertrochanteric fracture (31 A2.1, A2.2, A2.3), either by DHS of PFN osteosynthesis after randomization. A CT examination of both hip joints in a predefined manner was performed before surgery. Using special software the relative density of the central spherical part of the femoral head 2 and 3 centimetres in diameter was determined. After fracture healing, the dynamization of the neck screw of both implants and the reduction of vertical distance between the tip of the neck screw and subchondral bone of the femoral head were determined. In addition to evaluation of osteosynthesis stability and osteosyntheis failure, clinical parameters such as surgical time, blood loss and length of hospital stay were compared between the two groups of patients. Survival of patients was evaluated with respect to April 21, 2010. In the patient series, 4 failures of DHS osteosynthesis (cut out) and 2 failures of PFN osteosynthesis (cut out) were noted. Sliding of the DHS was on average 11,9 mm, and was significantly higher in comparison to dynamization of the PFN neck screw, which was 6,9 mm (p=0,005). When comparing the vertical distance between the tip of the neck screw and subchondral bone of the femoral head immediately after surgery and after fracture healing the average reduction of the vertical distance was 1,6 mm in DHS osteosynthesis and 0,8 mm in PFN osteosynthesis. The difference was statistically significant (p=0,025). PFN seems to provide a more stable fixation, based on the measurements. The number of failed DHS osteosyntheses is higher in comparison to the number of failed PFN osteosyntheses but the difference is not statistically significant. The influence of femoral head density on osteosynthesis failure could not be determined due to a low number of failed osteosyntheses in both patient groups. At the same time, after statistical analysis, influence of the relative femoral head density on vertical distance reduction between the screw tip and femoral head subchondral bone in healed fractures was not proven. Statistically, average length of surgical time, length of hospital stay, mean blood loss and survival did not differ significantly between the two patient groups.


Ragnhild Stoen Lars Nordsletten Jan Madsen Cathrine Lofthus Frede Frihagen

Introduction

Many patients with displaced intracapsular femoral neck fractures (IFNF) are treated with hemiarthroplasty (HA) which has been shown superior to internal fixation(IF) the first year after injury. Long term results, however, are sparse.

Methods

A total of 222 consecutive patients above 60 years, including mentally disabled, with IFNF were randomized to either internal fixation with two parallel screws or hemiarthroplasty, and operated by the surgeon on call. After 5 years, 68 of the 70 surviving patients accepted a follow-up visit. The reviewers were blinded for initial treatment.


Bernard Masson Thomas Pandorf

Introduction

In total hip arthroplasty ceramic on ceramic bearing couples are used more and more frequently and on a wordwide basis. The main reason of this choice is reduction of wear debris and osteolysis. The tribological properties and the mechanical behaviour of the implanted ceramic must remain the same throughout the patient's life.

The aim of this study was to evaluate the resistance of Alumina Matrix Composite to environmental degradation.

Material and method

The alumina matrix composite or BIOLOX ® delta is manufactured in Germany by CeramTec. It is made up of 80 vol.% Al2O3, 17 vol.% Yttria Stabilized ZrO2 and 3vol.% strontium aluminate platelets. The zirconia grains account for 1.3 mol.% of the Yttria content.

Accelerated aging tests in water steam at 142°C, 134°C, 121°C, and 105°C were performed to evaluate the aging kinetics of the composite.

X-ray diffraction was used to determine the monoclinic phase content on the material surface. Phase transformation is associated with weakness and increase in roughness of zirconia ceramic implants.


Kjell Matre Tarjei Vinje Leif Ivar Havelin Jan-Erik Gjertsen Ove Furnes Birgitte Espehaug Jonas Fevang

Introduction

The treatment of trochanteric and subtrochanteric fractures remains controversial, and new implants are constantly being developed trying to improve outcome and minimize the number of complications in these fractures.

In Norway the Sliding Hip Screw(SHS), with or without a Trochanteric Stabilizing Plate (TSP), is still the most commonly used implant, but worldwide nailing of these fractures is increasing. This trend, however, has not been supported by documentation of better clinical results compared to the SHS in well designed studies. Therefore, in the present study we compared the recently launched Trigen Intertan nail (Smith and Nephew) with the SHS in the treatment of trochanteric and subtrochanteric fractures.

Patients and Methods

In a prospective, randomized multicenter study with 697 patients, we compared the Trigen Intertan nail with the SHS regarding postoperative pain, functional mobility, complications, and reoperation rates.

Patients older than 60 years with trochanteric and subtrochanteric fractures were included in 5 hospitals. At day 5, and 3 and 12 months postoperatively, pain was measured using a Visual Analogue Scale (VAS), and the Timed Up and Go-test (TUG-test) was performed to evaluate functional mobility. Complications and reoperations were recorded at discharge, and after 3 and 12 months.


Rishi Chana Christina Esposito Patricia Campbell William Walter

Background

Pseudotumours have been associated with metal-on-metal (MoM) hip replacements. We define it as a solid mass which may have cystic components that is neither neoplastic nor infectious in aetiology. The cause of a pseudotumour is not fully understood but could be due to excessive wear, metal hypersensitivity or due to an as-yet unknown cause.

Aim

We present the retrieval analysis of early failure MoM hips revised for pain, loosening or a symptomatic mass. Tissues and implants were examined for the possible causes of failure and pseudotumour formation. Corrosion as a potential new cause for pseudotumour formation will be presented.


Martin Beck Sandro Kohl

INTRODUCTION

The lifetime of UHMWPE implants may be limited by wear and oxidative degeneration. Wear produced particles are in general biologically active, and may induce osteolysis. As threshold of PE wear rate below which osteolysis is rarely observed is postulated to be less tahn 0.1 mm per year. Moreover, PE delamination and breakage are consequences of the embrittlement of the PE due to oxidation. Both demonstrate, that improving the clinical behaviour of UHMWPE means reduction of wear particles. The first can be achieved by cross-linking the second by the anti-oxidative stabiliser vitamin E. The highly cross-linked PE vitamys ® used for the isoelastic monobloc cup RM Pressfit (Mathys AG Bettlach, Bettlach, Switzerland) is mixed with 0.1% of synthetic vitamin E and is the first and only highly cross-linked PE used in total hip replacement that meets all requirements for the best grade UHMWPE in yield strength, ultimate tensile strength and elongation at break.

METHODS AND MATERIAL

With the first implantation of RM Pressfit vitamys® a prospective multicentre study was started. So far 256 cases in 7 clinics from Europe and New Zealand are included. This report presents the first clinical experiences of one Swiss clinic from the multicentre study. Prospective data collection includes Harris Hip score (HHS), patient satisfaction and radiographic analysis. Clinical and radiographic follow-up is done after 6 weeks, 6, 12 and 24 months, and thereafter for long-term results. Standardized documentation of surgery and postoperative course is performed.


Christiaan Van Bergen Gabriëlle Tuijthof Leendert Blankevoort Mario Maas Gino Kerkhoffs C Van Dijk

PURPOSE

Osteochondral talar defects (OCDs) are sometimes located so far posteriorly that they may not be accessible by anterior arthroscopy, even with the ankle joint in full plantar flexion, because the talar dome is covered by the tibial plafond. It was hypothesized that computed tomography (CT) of the ankle in full plantar flexion could be useful for preoperative planning. The dual purpose of this study was, firstly, to test whether CT of the ankle joint in full plantar flexion is a reliable tool for the preoperative planning of anterior ankle arthroscopy for OCDs, and, secondly, to determine the area of the talar dome that can be reached by anterior ankle arthroscopy.

METHODS

In this prospective study, CT-scans with sagittal reconstructions were made of 46 consecutive patients with their affected ankle in full plantar flexion. In the first 20, the distance between the anterior border of the OCD and the anterior tibial plafond was measured both on the scans and during anterior ankle arthroscopy as the gold standard. Intra- and interobserver reliability of CT as well as agreement between CT and arthroscopy were assessed by intraclass correlation coefficients (ICCs) and a Bland and Altman graph. Next, the anterior and posterior borders of the talar dome as well as the anterior tibial plafond were marked on all 46 scans. Using a specially written computer routine, the anterior proportion of the talar dome not covered by the tibial plafond was calculated, both lateral and medial, indicating the accessible area.


Christiaan Van Bergen Mikel Reilingh C Van Dijk

Objectives

Osteochondral ankle defects (OCDs) mainly occur in a young, active population. In 63% of cases the defect is located on the medial talar dome. Arthroscopic debridement and microfracture is considered the primary treatment for defects up to 15 mm. To treat patients with a secondary OCD of the medial talar dome, a 15-mm diameter metal implant (HemiCAP ®) was developed. The set of 15 offset sizes was designed to correspond with the anatomy of various talar dome curvatures. Recently, two independent biomechanical cadaver studies were published, providing rationale for clinical use. The present study was undertaken to evaluate the clinical effectiveness and safety of the metal implantation technique for osteochondral lesions of the medial talar dome in a prospective study.

Material and methods

Since October 2007, twenty patients have been treated with the implant. Four patients who did not meet the inclusion criteria and four patients who had less than one-year follow-up at the time of writing were left out of this analysis. Twelve patients are reported with one year (n=8) or two years (n=4) follow-up. All patients had had one or two earlier operations without success. On preoperative CT-scanning, the mean lesion size was 16 × 11 (range, 9–26 × 8–14) mm. Outcome measures were: Numeric Rating Scale pain (NRS) at rest and when walking, Foot Ankle Outcome Score (FAOS), American Orthopaedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot score, and clinical and radiographic complications. Data are presented as median and range. The Wilcoxon signed ranks test was used to calculate p-values.


Matthijs Lipperts Rachel Senden Wim Van Asten Ide Heyligers Bernd Grimm

Introduction

In orthopaedics, clinical outcome assessment (COA) is mostly performed by questionnaires which suffer from subjectivity, a ceiling effect and pain dominance. Real life activity monitoring (AM) can objectively assess function and becomes now feasible as technology has become smaller, lighter, cheaper and easier to use. In this study we validated a custom made algorithm based on accelerometry using different orthopaedic patients with the aim to use AM in orthopaedic COA.

Methods

A small, lightweight 3D-accelerometer taped to the lateral side of the affected upper leg served as the activity monitor. AM algorithms were programmed in Matlab to classify standing, sitting, and walking. For validation a common protocol was used; subjects were asked to perform several tasks for 5 or 10 seconds in a fixed order. An observer noted the starting time of each task using a stopwatch.

Accuracy was calculated for the number of bouts per activity as well as total time per activity. 10 Subjects were chosen with different pathologies (e.g. post total knee/hip arthroplasty, osteoarthritis) since the difference in movement dynamics in each pathology poses a challenge to the algorithm.


Marcelo Queiroz Fabio Barros Daniel Daniachi Giancarlo Polesello Rodrigo Guimarães Walter Ricioli Nelson Ono Emerson Honda

Introduction

One of the most common complications of ceramic on ceramic hip replacement is squeaking. The association of Accolade stem and Trident acetabular system has been reported to have squeaking incidence of up to 35,6%. There is doubt if this phenomenon occurs due to: the stem titanium alloy, the V40 femoral neck, the recessed liner of the trident cup or even the mal-seating of the trident insert on the cup.

Objectives

Primary: The purpose of the present study was to determine the incidence of squeaking in association with the use of Exeter stem and Trident ceramic acetabular system. Secondary: Analysis of the correlation of the cup abduction angle and squeaking.


Peter Loughenbury Anwar Owais Lynne Taylor J Macfie Mark Andrews

Introduction

Obesity has been associated with higher complication rates and poorer outcomes following joint replacement surgery. Body mass index (BMI) is a simple index of body composition and forms part of preoperative assessment. It does not take into account the proportion of lean mass and body fat and can give a false impression of body composition in healthy manual workers. A more accurate measure of body composition is available using non-invasive bioimpedance methods. This study aims to identify whether BMI provides an accurate measure of body fat composition in patients awaiting lower limb arthroplasty surgery.

Methods

Consecutive patients attending for pre-assessment clinic prior to total knee and hip replacement surgery were examined. All patients had their BMI calculated and underwent bioimpedance testing using a bedside Bodystat 1500 scanner (Bodystat, UK).


Yoshinori Ishii Hideo Noguchi Mitsuhiro Takeda Junkoh Sato

The purpose of this study is to analyze what kind of pattern of change in each posterior femoral condyle allows for a greater degree of flexion after total knee arthroplasty (TKA). The flexion angle was assessed pre-operatively, and at 12 months after the surgery in 98 patients (106 knees) who underwent consecutive TKA. We used a quantitative 3 dimensional technique using computed tomography for the assessment of changes in both the medial and lateral femoral condylar offset. There were no significant correlation between changes of each posterior condylar offset and post flexion angle (medial condyle; R=−0.038, p=0.70, lateral condyle; R=−0.090, p=0.36). There were no significant differences between changing patterns and increase rate of flexion (p=0.443). Additionally there were no significant differences between changing patterns and increase of flexion angle (p=0.593). Changes of each posterior condylar offset were no correlation to knee flexion after TKA in the current design prosthesis.


Azad Hussain Azad Hussain Amir Kamali Chenxi Li Joesph Pamu Roger Ashton

INTRODUCTION

Analysis of retrieved ceramic components have shown areas of localized ‘stripe wear’, which have been attributed to joint laxity and/or impingement resulting in subluxation of the head, causing wear on the edge of the cup. Studies have been conducted into the effects of mild subluxation, however few in vitro tests have looked at severe subluxation. The aim of this study was to develop a more clinically relevant subluxation protocol.

MATERIALS & METHODS

Seven (Subluxation n=4; standard test n=3) of 36mm Biolox Forte (R3, Smith & Nephew) ceramic devices were tested for 0.5m cycles (mc). Two of the subluxed joints were further tested to 1 Mc. The devices were subjected to subluxation under standard testing conditions. The flex/ext was 30° and 15° respectively, with internal/external rotation of ±10°. The force was Paul type stance phase loading with a maximum load of 3 kN, and a standard ISO swing phase load of 0.3 kN at 1 Hz.

The test was conducted on a ProSim hip joint wear simulator (SimSol, UK). The simulator is equipped with a novel mechanism to achieve translation of the head, to achieve subluxation. During the ISO swing phase load of 0.3kN, a controlled lateral force required for the translation of the head is applied by a cam mechanism, head retraction then occurs during heel strike.

The lubricant used was new born calf serum diluted with de-ionised water to achieve average protein concentration of 20 g/l, with 0.2 wt % concentration NaN3, and changed every 250k cycles. Measurements have been taken at 0.5 & 1 mc stages.


Pietro Ruggieri Andrea Angelini Gabriele Drago Giovanni Guerra Giuseppe Ussia Andreas Mavrogenis Mario Mercuri

Introduction

Telangiectatic osteosarcoma (TOS) is a rare subtype of osteosarcoma. We review our experience to characterize its prevalence, treatment, relapse and survivorship at long term follow-up.

Methods

Eighty-seven patients aged from 4 to 60 years (mean 20 years), were treated from 1985 to 2008. Lesions affected the femur (38), humerus (20), tibia (19), fibula (4), pelvis (3), foot (2) and radius (1). Eight patients had metastatic disease at diagnosis. Seventy-eight patients were treated with neoadjuvant chemotherapy with three or more drugs according to different protocols, nine had surgery as first treatment. Limb salvage surgery was performed in 71 cases, amputation in 14 and rotationplasty in one. One patient died before surgery. Prognostic factors were evaluated with Kaplan-Meier analysis.


Richard Field Karthig Rajakulendran Neil Rushton

Introduction

The MITCH PCR is an anatomic, flexible, horse-shoe shaped acetabular component, with 2 polar fins. The rationale of the PCR cup design is to reproduce a near-physiological stress distribution in the bone adjacent to the prosthesis. The thin composite cup is designed to fuse and flex in harmony with the surrounding bony structure. Only the pathological acetabular cartilage and underlying subchondral bone of the horseshoe-shaped, load-bearing portion of the acetabular socket is replaced, thus preserving viable bone stock. The PCR is manufactured from injection moulded carbon fibre reinforced polyetheretherketone (PEEK), with a two layer outer surface comprising hydroxyapatite and plasma sprayed commercially pure titanium. It is implanted in conjunction with a large diameter low wear femoral head, producing a bearing that will generate minimal wear debris with relatively inert particles.

Pre-clinical mechanical testing, finite element analysis and biocompatibility studies have been undertaken. FEA evaluation predicts preservation of host bone density in the load bearing segments. A pilot clinical study was completed on a proto-type version of the PCR cup (the “Cambridge” cup), achieving excellent 5 and 10 year results.

Subjects and Methods

We report the three-year results from a two-centre, prospective clinical evaluation study of the MITCH PCR cup. Patient outcome has been assessed using standardised clinical and radiological examinations and validated questionnaires. The change in physical level of activity and quality of life has been assessed using the Oxford Hip Score, Harris Hip score and the EuroQol-5D score, at scheduled time-points. Serial radiographs have been analysed to monitor the fixation and stability of the components.


Etsuo Shoda Kiyoshi Ouchi Shigeki Maruyama Akiko Suzuki Shinpei Kitada

INTRODUCTION

Short femoral nail is the most popular instrumentation for femoral trochanteric fractures. PFNA is in widely use and good results are reported. In these papers, fracture classification and evaluation of surgical results were based on plain X-ray. However, some cases of delayed union, non-union, and blade cut out showed no critical problems in immediate postoperative X-ray. Cause of these complications was not able to solve in X-ray analysis. CT scan provides more information about fracture pattern and position of nail and blade. CT analysis is likely to solve the cause of these complications.

MATERIALS & METHODS

20 cases of 36 femoral trochanteric fractures treated with PFNA-II were evaluated by CT scan (pre and post surgery). Four males and 16 females, and average age at surgery was 80.5 (65–100). Eleven cases were A1 fracture and 9 cases were A2 fracture in AO classification.

Nail insertion hole was made by custom made Hollow Reamer.

Fracture classification with 3D-CT (Nakano's classification), position of nail insertion hole (relationship between neck or head), and postoperative evaluation with 3D-CT insertion part of nail and blade were investigated.


Charles Bragdon Henrik Malchau Merideth Greene Michael Doerner Roger Emerson Peter Gebuhr James Huddleston Eduardo Cimbrelo

Introduction

Proper cup positioning is a critical component in the success of total hip arthroplasty surgery. A multicenter study has been initiated to study a new type of highly cross-linked polyethylene. This study provides a unique opportunity to a review the acetabular cup placement of over 500 patients implanted in the past 2 years from 13 medical centers from the U.S., Mexico, and Europe.

Methods

482 patients have received primary total hip arthroplasty using components from a single manufacturer in 5 centers in the US and Mexico and 7 centers in Europe. The acetabular anteversion and inclination were measured in post-operative radiographs. An acceptable window of cup position is defined at 5–25° of anteversion and 30–45° of inclination.


Bregje Thomassen Laurens Pool Rudolf Van Der Flier Rudolf Stienstra

High volume infiltration with local anaesthetics (LIA) during total knee arthroplasty (TKA) for postoperative pain relief may be beneficial as compared to traditional methods. Retransfusion drains are used in TKA as alternative for allogeneic blood transfusions. When combining both modalities, recollected blood may contain large doses of local anaesthetics potentially leading to systemic toxicity during retransfusion. We investigated the safety of combining LIA and retransfusion of shed blood.

Twenty patients scheduled for primary TKA were included. During surgery two peri-articular injections with ropivacaine (total 375 mg) were given. Patients received an intraarticular retransfusion drain and a wound catheter for continuous infusion of ropivacaine (8 mg/hr) for 24 hours. Blood collected in the retransfusion device, was not retransfused but used for laboratory analyses. Patients’ blood samples were taken immediately after surgery, 3, 6 and 24 hours postoperatively. We predicted cumulative ropivacaine concentrations using patient and shed blood samples from 6 hours postoperatively. We modelled instant retransfusion by estimating the cumulative plasma concentrations. Our safety threshold was 0.15 mg/L unbound ropivacaine in a venous plasma sample, based on literature.

Total ropivacaine concentration was highest 24 hours postoperatively and unbound ropivacaine was maximal predominantly at 6 hours. Total ropivacaine concentrations ranged from 0.7 to 1.9 mg/L and unbound ropivacaine concentrations varied between 0.03 and 0.11 mg/L. At 6 hours median shed blood volume was 600 mL (range 303–869 mL). Interestingly was the difference (mean ± SD) in free fraction ropivacaine, in shed blood (68.8–4.6%) and in plasma (4.8 ± 1.1%).

Assuming retransfusion, an average 13 mg (range 6–18mg) of unbound ropivacaine would have been administered intravenously. The model used to estimate cumulative ropivacaine plasma levels showed that instant retransfusion potentially would have led to unbound venous plasma concentrations of above 0.15 mg/L.

Under the conditions in our study it is safe to use LIA in combination with continuous infusion of ropivacaine. However, in combination with the retransfusion of shed blood collected with the Bellovac ABT system this may lead to toxic levels. Before implementing the combination of both modalities formal testing is required.


Yaron Brin Ezequiel Palmanovich Meir Nyska Benyamin Kish

Background

Hip fractures affect annually over 350,000 people in the USA and over 1.6 million worldwide. About 50% of these numbers are intertrochanteric fractures,

The surgeon should be able to minimize the morbidity associated with the fracture by: recognizing the fracture pattern, choosing the appropriate fixation device, performing accurate reductions with ideal implant placement and being conscious of implant costs. In this study we assessed the ability of the orthopaedic surgeons to recognize fractures pattern, and choosing the ideal implant for the recognized fracture.

Methods

We assessed 134 orthopaedic surgeons with questionnaires that assessed 14 different intertrochanteric femoral fractures. We evaluated the fractures as stable or unstable. We chose for each fracture the appropriate fixation device: either a Dynamic Hip Screw (for stable fractures) or an Intra Medullary Nail (for unstable ones), taking into consideration fracture's stability and implants’ costs. We compared the answers of the assessed surgeons to ours.


Walter Van Der Weegen Henk Hoekstra Thea Sybesma

INTRODUCTION

Cementless Total Hip Replacement surgery is a well established procedure for relative young patients with severe hip disease. Excellent long term clinical results have been published on the performance of the femoral component. With growing clinical experience, our concern focused on excessive wear of the Ultra High Molecular Weight Polyethylene (UHMWPE) ringloc liner of the Mallory Head cementless Total Hip Prosthesis. After its introduction in our clinic in 1997, this implant is still in use without any modification. We were concerned that due to premature liner wear, the performance of this implant would not be compliant with the international guideline on implant survival (NICE guidelines: at 10 year follow up, 90% of all implants should still be in situ). Our objective was to establish the amount of liner wear in our first 200 MH implants.

METHODS

Our first 200 patients consecutively treated with Mallory Head prostheses were followed up to obtain a recent digital image. Follow up was complete for 181 (90.5%) of our 200 patients. Ten had died and nine were not able or willing to come for follow up. The mean duration of follow up was 8.3 years (range: 8–13). The 181 recent digital images were classified as either excessive wear or no excessive wear by two independent orthopedic surgeons. Next, liner wear was measured in the 2D frontal plane using PolyWare Pro/3D Digital Version Rev 5.1 software (Draftware Developers, Conway, USA). A threshold for excessive liner wear was set at 0.2mm/year, according to literature.


George Grammatopoulos Hemant Pandit Adrian Taylor Duncan Whitwell Sion Glyn-Jones Roger Gundle Peter Mclardy-Smith Harinderjit Gill David Murray

Introduction

Since the introduction of 3rd generation Metal-on-Metal-Hip-Resurfacing-Arthroplasty (MoMHRA), thousands of such prostheses have been implanted worldwide in younger patients with end-stage hip osteoarthritis. However, no independent centre has reported their medium-to-long term outcome. The aim of this study is to report the ten year survival and outcome of the Birmingham Hip Resurfacing (BHR), the most commonly used MoMHRA worldwide.

Methods

Since 1999, 648 BHRs were implanted in 555 patients, the majority of which were male (326). The mean age at surgery was 52.1years (range: 17–82), with primary OA as most common indication (85%). Mean follow up was 7.1years (range: 1–11). The Oxford Hip Score (OHS) and UCLA questionnaires were sent to all patients. Implant survival was established, with revision as the end point. Sub-analysis was performed by gender, femoral component size (small: <45mm, standard: 46–52, large: >53mm) and age at surgery (young:<50yrs, old:>50yrs).


Edwin Su

Hip resurfacing has grown rapidly since its introduction in the United States, as an alternative to total hip replacement in the younger, active patient. Some studies have suggested a steep learning curve and a higher complication rate when compared to THR. Existing studies have originated from the pioneering surgeons, using a specific type of resurfacing implant. The purpose of this study was to look at the experience of a single, non-inventor surgeon with the adoption of hip resurfacing, using 3 different implants.

M&M

All consecutive hip resurfacings performed by the senior surgeon between 2004 and 2008 were included, providing a minimum 2 year followup period. 3 different implant types were used; 2 of these were used as part of the clinical trials, and 1 was used after US FDA approval. A total of 560 hip resurfacings were eligible for the study based upon a minimum of 2 year followup.

Results

Nine revisions were performed in this cohort (1.6%). 2 were femoral conversions to endoprostheses for femoral neck fracture; 3 additional femoral conversions were done for osteonecrosis of the femoral head. 1 acetabular revision only was performed for malposition. 2 revisions to THR of both the acetabular and femoral components were done for acetabular loosening and excessive metal production (edge loading). There was 1 revision for metal hypersensitivity. Overall, the K-M survival curve is 98.1% at 4 years. There was no difference with regard to survival from additional surgery with regard to the different implant types.

Radiographic signs of failure were also documented. In this cohort, 3 femoral and 1 acetabular components were identified to be radiographically loose, giving a K-M survival from clinical and radiographic failure to be 96.8% at 4 years.


Ben Kendrick John Weston-Simons Frank Sim Max Gibbons Hemant Pandit Harinderjit Gill Andrew Price Christopher Dodd David Murray

Introduction

Radiolucencies beneath the tibial component are well recognized in knee arthroplasty; the aetiology and significance are poorly understood. Non-progressive narrow radiolucencies with a sclerotic margin are thought not to be indicative of loosening. Factors which decrease the incidence of radiolucencies include cementless fixation and the use of pulse lavage. Leg/component alignment or BMI do not influence radiolucency. We are not aware of any studies that have looked at the effect of load type on radiolucency.

The Oxford domed lateral tibial component was introduced to decrease the bearing dislocation rate that was unacceptably high with the flat tibial tray. However, the introduction of the domed tibial component alters the forces transmitted through the implant-cement-bone interface. As the Oxford UKR uses a fully congruent mobile bearing, the forces transmitted through the interface with a flat tray are compressive, except for the effect of friction. However, with the domed tibial component shear forces are introduced. The aim of this study was to assess the prevalence of radiolucency beneath the previous flat design and the new domed tibial tray.

Patients and methods

A consecutive series of 248 cemented lateral UKRs (1999–2009) at a single institution were assessed. The first 55 were with a flat tibia and the subsequent 193 with a domed component. One year post-op radiographs were assessed, by two observers, for the presence (full or partial) and distribution of radiolucency. The distribution and thickness of each radiolucency. Cases were excluded for missing or poorly aligned radiographs.


Axel Weusten Axel Weusten Simon Jameson Philip James Robert Sanders Andrew Port Mike Reed

Background

Medical complications and death are rare events following elective orthopaedic surgery. Diagnostic and operative codes are routinely collected on every patient admitted to hospital in the English NHS (hospital episode statistics, HES). This is the first study investigating rates of these events following total joint replacement (TJR) on a national scale in the NHS.

Methods

All patients (585177 patients) who underwent TJR (hip arthroplasty [THR], knee arthroplasty [TKR], or hip resurfacing) between January 2005 and February 2010 in the English NHS were identified. Patients were subdivided based on Charlson co-morbidity score. HES data in the form of OPCS and ICD-10 codes were used to establish 30-day medical complication rates from myocardial infarction (MI), cerebrovascular event (CVA), chest infection (LRTI), renal failure (RF), pulmonary embolus (PE) and inpatient 90-day mortality (MR).


Simon Sturdee Dj Duffy Rozalia Dimitriou Peter Giannoudis Peter Templeton

Purpose

The purpose of this study was to prospectively evaluate the rehabilitation outcome of children following operative and non-operative stabilisation of long bone fractures sustained in conjunction with an acquired brain injury (ABI).

Materials and Methods

Between 1996 and 2002, children up to 16 years of age who were admitted to the Paediatric Intensive Care Unit (PICU) with an ABI and concomitant tibial or femoral shaft fractures were considered eligible for inclusion. Children who died or were unable to walk before the accident were excluded. All data relating to the sustained injuries, the duration of PICU inpatient stay, the fracture treatment and the functional outcome were collected prospectively. The severity of the injuries was assessed using the Injury Severity Score (ISS) and the Glasgow Coma Score (GCS). The duration of time was taken from admission to reaching rehabilitation milestones; the ability to sit, stand and walk was then assessed. Total duration of hospital inpatient stay and mobility on discharge were also recorded. Operative skeletal stabilisation included external or internal fixation, as well as flexible intramedullary nailing. Statistical analysis was performed using the Mann-Whitney U Test.


Christian Madsen Henrik Joergensen Bent Lind Henning Ogarrio Benn Duus Jes Lauritzen

Introduction

The calcium-PTH-vitamin D-axis has long been highlighted for its effects on bone status and much interest has been given to how this relates to the risk of sustaining an osteoporotic fracture. Little attention has on the other hand been given to how disturbances in this axis, as for example secondary hyperparathyroidism (SHPT), relate to mortality among hip fracture patients. We therefore wanted to determine if SHPT could predict mortality in this group of patients.

Methods

The study included 562 hip fracture patients (HF) (age 70 years) admitted to a Danish university hospital. Each hip fracture patient was exactly matched according to age and sex with two controls randomly chosen from a control population of approximately 248000 subjects. The control group (Con) (n=1124) consists of subjects who have had PTH, total calcium (Ca) and 25OH-vitamin D (VitD) measured at the General Practitioners Laboratory of Copenhagen after referral from their general practitioner. Of the HF's 462 had a Ca measurement, 440 had a PTH measurement and 439 had a VitD measurement.

Basic characteristics (values for age, Ca, PTH and VitD are mean (SD)): Sex (females/males) (%): 73.8/26.2. Age (years): 82.9 (5.7). Ca (mmol/l): Con 2.34 (0.13), HF 2.27 (0.13), p<0.0001 (chi-square). PTH (pmol/l): Con 6.4 (5.8), HF 6.6 (5.4), p=0.4 (chi-square). VitD (nmol/l): Con 53.3 (30.1), HF 49.3 (29.6), p=0.02 (chi-square).


Lars Solgaard Lars Moeller Torben Sandberg

Introduction

Unicompartmental arthroplasty is still a controversial issue in knee replacement, mainly due to a marked variation in published survival rates of the implants. The aim of this study was to analyse possible risk factors for revision following Oxford unicompartmental knee arthroplasties (OUKA).

Material and methods

Since 1997 data for all patients with primary and revision knee arthroplasties performed in our department have been stored in a database. Selected for the present study was all primary OUKA performed in the period 1997–2006 as well as any revision following these operations until the end of 2008. We got information from The National Health Register and the CPR register about any revision performed at other institutions and date in case of death. Primary OUKA were grouped in three categories according to the experience of the surgeon: 1 for operation done by a surgeon who had performed less than 20 OUKA, 2 for operation by a surgeon who had performed 20–40, and 3 for operation by a surgeon who had performed more than 40. Risk of revision was analysed by Cox regression. Revisions due to pain as the only reason were excluded from the analyses. Age and gender of the patients, previous surgical intervention, operation time, and the experience of the surgeon were included as possible risk factors in the analysis.


Vijay Kumar Tushar Gupta Anjan Trikha Rajesh Malhotra

Background

We compared pain relief after total hip arthroplasty using periarticular intraoperative injection along with single dose post operative injection of local anesthetic (THA) with the well-established practice of epidural infusion.

Methods

70 patients undergoing elective THA under combined spinal anaesthesia were randomly assigned to receive either (1) continuous epidural infusion (group B) or (2) infiltration around the hip joint with a mixture of 100 ml of bupivacaine (2 mg/ml) + 1ml ketorolac (30mg/ml) and 0.5ml epinephrine (1mg/ml) at the conclusion of surgery combined with one postoperative intraarticular injection of 20 ml. of Bupivacaine 0.5% + 1ml ketorolac (30mg/ml)+ 0.5 ml. epinephrine (1mg/ml) through an intraarticular catheter (group A).

All patients received acetoaminophen 1gm 8 hourly for 72 hrs and injection ketoralac 30mg every 6 hourly IV(15mg if >65 yr 30mg if <65 yr). Breakthrough pain in any group (VAS >7) was treated by injection fentanyl 20 μg bolus at 10 min. interval till VAS reduced to < 4. If VAS 4–7 injection tramadol 50mg IV was given if VAS continued to be >4 after 15 min. then injection fentanyl 20 μg bolus was given at 10 min interval till VAS <4.


Antonio Moroni Martha Hoque Giovanni Micera Fabrizio Sinapi Lucia Calbucci Elena Maccagnan Sandro Giannini

Introduction

Metal-on-metal hip resurfacing (MOMHR) is a good surgical indication for young active patients. However, it cannot be used in patients with an excessively short femoral head/neck. To address these cases, a new surgical technique has been developed comprising femoral head augmentation using impacted morcellized bone grafts.

Methods

32 osteoarthritis patients who had severe congenital insufficiency of the femoral head/neck were treated with MOMHR combined with femoral head augmentation. Mean patient age was 49 ± 9 years (18–66). The required amount of augmentation was calculated on preoperative X-rays and confirmed during surgery. Using specially designed instrumentation, bone chips produced while reaming the socket and trimming the head were impacted onto the head to achieve the desired reconstruction and lengthening. Finally, the femoral component was cemented.


Patrick Weber Christian Schröder Sandra Utzschneider Volkmar Jansson Peter Müller

Introduction

Unicompartmental knee arthroplasty (UKA) in patients with isolated medial osteoarthritis of the knee is nowadays a standard procedure with good results, especially with the minimally-invasive approach. However, the survival rate of the unicompartmental knee prostheses is inferior to that of total knee prostheses. Therefore, further studying of UKA is still necessary. In most mobile bearing designs the femoral component has a spherical surface and therefore its positioning is not crucial. The role of the tibial slope in UKA has not been investigated so far. The manufacturers recommend tibial slopes with values between 10° positive slope and 5° negative slope. Most surgeons try to reconstruct the anatomical slope with a high failure by measuring the slope on x-rays. The aim of this study was to investigate the influence of the tibial slope on the wear rate of a medial UKA.

Materials and methods

In vitro wear simulation of medial mobile bearing unicompartmental knee prosthesis with a spherical femoral surface (Univation ®) was performed with a customized four-station servo-hydraulic knee wear simulator (EndoLab GmbH, Thansau, Germany) reproducing exactly the walking cycle as specified in ISO 14243–1:2002(E). The tibial tray was inserted with 2 different medial tibial slopes: 0°, 8° (n=3 for each group). The lateral tibial slope of the space-holder was not changed (0° for every group). We performed a total of 5 million cycles for every different slope, the gravimetric wear rate was determined gravimetrically using an analytical balance every 500 000 cycles according to the ISO 14243–2.


Mikela Maric Marko Bergovec Anita Viskovic Robert Kolundzic Miroslav Smerdelj Dubravko Orlic

AIM

To present our experience in patients treated under primary diagnosis giant cell tumor of bone at Department Orthopaedic Surgery Zagreb University School of Medicine in a 15-year period from 1995 to 2009.

METHODS

We performed a retrospective study of all patients treated in our Department because of giant cell tumor of bone (GCT) from 1995 to 2009. The mean age of our patients was 29,9 years (range: 14 to 70 years). Sex distribution showed prevalence in female (F:M=23:12=66%:34%). All together, 39 patients were operated under primary diagnosis of GCT. Four patients were lost in follow-up. In total, 35 patients were included in study. Diagnosis of GCT was made according to clinical, imaging and histological findings, and distributed by Campanacci's classification.


Bhavuk Garg Vijay Kumar Rajesh Malhotra Prakash Kotwal Mohit Madan

Introduction

Locking plates have been especially useful in the treatment of osteoporotic fractures. This study aimed to investigate the role of locking plate in femoral fractures in patients with osteogenesis imperfecta.

Material & Methods

6 male patients with osteogenesis imperfecta were operated for femoral fractures using locking compression plate. Their age ranged between 4 and 14 years. They were kept non weight bearing till the fracture united.


Ammar Al Khudairy Omar Al-Hadeedi Murali Sayana John Quinlan

Introduction

Increasing numbers of elderly patients are being prescribed Clopidogrel, an anti-platelet agent for medical reasons. There are no international guidelines as to the management of patients with hip fractures on Clopidogrel in peri-operative period especially in relation to timing of the surgery. In Waterford Regional Hospital in Ireland, hip fracture surgery is deferred for 4 days and platelets are reserved for the operative/post-operative period, in case they have significant bleeding or an associated complication. We conducted a retrospective study on patients admitted over a period of 1 year.

Materials and methods

A retrospective review of case notes was performed on all the hip fractures on Clopidogrel that had been admitted over last 1 year. Age, Sex, ASA, number of cancellations, operation performed, length of stay, post-op complications including wound, blood & platelet transfusions data were recorded.


Antonio Berizzi Stefano Zanarella Erica Lelio Roberto Aldegheri

Introduction

treatment of femoral neck fractures in the physically active elderly, is still an open question. The comparison of total replacement and partial hip replacement showed substantial superiority of the first approach than the latter. We can not disregard the problems that THR can lead in the elderly: more surgical time, greater blood loss, major sacrifice of bone in osteoporotic subjects. The Tribofit® acetabular system, has the objective to overcome these problems with the implantation of a single 3mm soft, pliable buffer made of polycarbonate-urethane between the large diameter metal femoral head and the subchondral bone, thus replacing the articular cartilage. The surgical technique includes the reaming of the cartilage layer, the creation of a circumferential groove and the snap-fit insertion of the buffer.

The purpose of the prospective study was to evaluate the effectiveness of this approach in the treatment of femoral neck fractures in the elderly.

Materials and Methods

from September 2008 to July 2010 we performed 45 implants with the Tribofit® Acetabular Buffer (Active Implants®, Memphis TN, USA). The inclusion criteria for the study were: femoral neck fracture patients over 75 years of age, physically independent before the injury, with good life expectancy, mild or absent arthritis, absence of morphological alterations of the acetabulum. The average age of these patients was 81,2 (75–89), the sex distribution was 36 females and 9 males, with 22 fractures of the left hip and 23 of the right. In all cases an uncemented straight femoral stem was implanted.

We recorded per-operative blood loss and intra-per-operative problems encountered. Follow-up were performed at 1, 3, 6 and 12 months post-op with radiographic control and clinical examination. The clinical outcome was objectively measured by the Harris Hip Score, pain Visual Analogue Scale and SF-36 questionnaire.


Ramin Espandar Seyed Mohammad Javad Mortazavi Mohammad Hasan Kaseb Babak Haghpanah Shideh Yazdanian

Background

Medial opening-wedge high tibial osteotomy is one of the common surgical procedures in treatment of knee deformities. Many methods have been proposed to fill the medial side osseous gap. The results of using allograft as void filler compared to iliac crest autograft has not been subject to a randomized clinical trial. The purpose of this study was to examine the results of medial opening-wedge high tibial osteotomy using iliac crest allograft as compared to iliac crest autograft.

Materials & Methods

Forty-six patients with genovarum deformity were enrolled based on specific inclusion and exclusion criteria and were randomly assigned into two groups. Medial opening-wedge high tibial osteotomy was done using iliac crest allograft (23 patients) or autograft (23 patients) and the osteotomy site was internally fixed using proximal tibial T-plate. All patients were followed-up to 12 months after surgery. Anatomical indices of proximal tibia, complications of treatment, and functional outcome (using WOMAC osteoarthritis index) were assessed for both groups.


J.M. Buchanan R.D Fletcher P. Linsley

Aims

Will Hydroxyapatite hip (HA) arthroplasty associated with ceramic bearings produce uncomplicated function in younger, active patients’ The incidence of aseptic loosening, dislocation and broken implants has been particularly investigated.

Debris disease from plastic debris contributes to aseptic loosening. Hard-Hard bearings should obviate this problem. Metal-metal will release ions which might be deleterious. Experience with metal-metal resurfacing has high lighted problems including pseudo-tumours. Ceramic bearings may fracture but otherwise appear free of complications.

Methods

This is a study extending over 19 years of 626 HA hip arthroplasties with ceramic bearings. Annual review using Harris Hip Score to assess pain and function and X-rays to check osseointegration has been performed. Alumina ceramic was inserted in 467 hips. The newer Zirconia Toughened Alumina (ZTA) has been inserted in 169 hips. There are 118 hips still under review at 10 or more years.


Full Access
Andrew Monk George Grammatopoulos Minsi Chen Max Gibbons David Beard Harinderjit Gill David Murray

Introduction

Osteoarthritis (OA) of the hip is an important cause of pain and morbidity. The mechanisms and pathogenesis of OA'sdevelopment remain unknown. Minor acetabular dysplasia and subtle variations in proximal femoral morphology are increasingly being recognized as factors that potentially compromise the joint biomechanically and lead to OA. Previous studies have shown that risk of hip OA increased as the femoral head to femoral neck ratio (HNR) decreased. Previous work has described the evolutionary change in inferior femoral neck trabecular density and geometry associated with upright stance, but no study has highlighted the evolutionary change in HNR. The aim of this study was to examine evolutionary evidence that the hominin bipedal stance has lead to alterations in HNR that would predispose humans to hip OA.

Methods

A collaboration with The Natural History Museums of London, Oxford and the Department of Zoology, University of Oxford provided specimens from the Devonian, Jurassic, Cretaceous, Miocene, Palaeolithic and Pleistocene periods to modern day. Specimens included amphibious reptiles, dinosaurs, shrews, tupaiae, lemurs, African ground apes, Lucy (A. Afarensis), H. Erectus, H. Neaderthalis and humans. Species were grouped according to gait pattern; HAKF (hip and knee flexed), Arboreal (ability to stand with hip and knee joints extended) and hominin/bi-pedal. Imaging of specimens was performed using a 64 slice CT scanner. Three-dimensional skeletal geometries were segmented using MIMICS software. Anatomical measurements from bony landmarks were performed to describe changes in HNR, in the coronal plane of the different specimens over time using custom software. Measurements of HNR from the specimens were compared with HNR measurements made from AP pelvic radiographs of 119 normal subjects and 210 patients with known hip OA listed for hip arthroplasty.


Arfan Malhi Eric Bohm David Hedden Colin Burnell Thomas Turgeon

Introduction

The purpose of this study was to compare the clinical outcomes and complications following bilateral simultaneous total knee arthroplasty in high body mass index (BMI) patients(>30kg/m2) to those of patients with a BMI<30 kg/m2.

Materials and Methods

Using data from an academic arthroplasty database and review of clinic charts we obtained health related quality of life (SF-12), and disease specific functional outcome scores (WOMAC or Oxford Knee Score). We also assessed length of hospital stay, ASA grade and transfusion requirements. Sixty six patients had a BMI<30 and 151 patients had a BMI>30.


Clément Silvestre Jean-Marc Mac Thiong Radwan Hilmi Pierre Roussouly

Background Context

Different minimally invasive approaches to the lumbar spine have been proposed but they can be associated with increased risk of complications, steep learning curve and longer operative time.

Purpose

To report the complications associated with a minimally invasive technique of retroperitoneal anterolateral approach to the lumbar spine.


Gianluca Cinotti Giuseppe Giannicola Emiliano Ferrari Alessandro Corsi Mara Riminucci Paolo Bianco

Posterolateral spinal fusion (PSLSF) in rabbits is a challenging model for bone substitutes because the transverse processes are extremely thin and the space to be filled with bone is greater than critical and meiopragic in terms of vascularity.

Several investigators have shown beneficial effects of PRP in bone and soft-tissue healing processes. However, controversial results have been reported in clinical setting analysing the effectiveness of PRP. Aim of the present study was to test the effectiveness of PRP in experimental model of PLSF in rabbits.

MATERIAL AND METHODS

20 White females New Zeland Rabbits were used. Seven rabbits (Group 1) had PRP plus carrier on the right side (Group 1A) and plus carrier and fresh bone marrow on the left side (Group 1B). Seven rabbits (Group 2) had carrier alone on the right side (Group 2A) and carrier plus fresh bone marrow on the left side (Group 2B). Six rabbits (Group 3) had sham operation on both right and left sides. Animals were sacrificed 6 months after surgery and the lumbar spine submitted to radiolographic and histologic analysis. Vascular density (VD) was also assessed in the different zone of the grafted material.

RESULTS

Radiographs showed a complete fusion in 83% of group 1A and in 83% of group 1B, and in 86% of group 2A and 2B. Pseudarthrosis or non union, was observed in 1 specimen of group 1B and 2A and in all specimens of group 3 (sham). In contrast to radiographic results, no specimen showed a complete bony bridge between the transverse processes on histologic analysis. VD was significantly greater in the periapophyseal compared to the interapophyseal region of the graft material. However, no significant difference was found in the VD between groups.


Tine Nymark Lars Lindoe Ahsan Al-Maleh

Introduction

The length of hospital stay following a hip fracture has decreased significantly during the past decades. Knowing that a hip fracture patient is often one with several comorbidities and high mortality, is it possible to further decrease the length of stay without compromising the quality of care?

Setting

Prior to November 2007 a hip fracture patient at Svendborg Hospital would be admitted to the orthopedic department. Postoperatively the patient would be treated by the orthopedic surgeons. If needed a geriatric consult could occur. If the patient was eligible she could be transferred to the geriatric department for further rehabilitation.

After November 2007 eight orthopedic beds were dedicated to hip fracture patients, in an orthogeriatric setting. The patient was treated operatively by the orthopedic surgeons, and then a geriatric consultant was responsible for the rest of the stay. Nurses and therapists were dedicated to the care of hip fracture patients, and had recieved special training regarding. The patient would stay in the same bed throughout the hospitalisation.


Kareem Elsorafy Ahmad Mchaourab Sunny Deo

A simple classification system, NOF complexity classification, was developed at the Great Western Hospital Trauma and Orthopaedic department, allowing stratification of resources. This is a four-group classification system, each group with two elements, firstly the patients medical fitness and secondly the complexity of the fracture. (C0=medically fit + simple fracture, C1=medically fit + complex fracture, C2=medically unfit + simple fracture, C3=medically unfit + complex fracture)

Between June 2008 and June 2009, data was collected retrospectively for 290 patients during a weekly MDT meeting to enter data that has been gathered into a departmental database to monitor our performance. The outcomes that we looked for to test the validity of this classification are the thirty-day mortality, annual mortality and length of hospital stay all stratified by complexity.

Results showed that there has been a strong correlation between the complexity classification and the 30-day and annual mortality with P values of 0.015 and 0.008 respectively. This resulted in a 30-day mortality of 4.4%, which is half the national average. Our average length of stay was equal to the national average of 23 days.

This classification system has allowed an improvement in service by adapting a classification system, which is understood by both the Orthogeriatric and Orthopaedic teams.


Daud Chou Girish Swamy James Lewis Nitin Badhe

Introduction

There has been renewed interest in the unicompartmental knee arthroplasty with reports of good long term outcomes. Advantages over a more extensive knee replacement include: preservation of bone stock, retention of both cruciate ligaments, preservation of other compartments and better knee kinematics. However, a number of authors have commented on the problem of osseous defects requiring technically difficult revision surgery. Furthermore, a number of recent national register studies have shown inferior survivorship when compared to total knee arthroplasty.

The purpose of this study was to review the cases of our patients who had a revision total knee arthroplasty for failed unicompartmental knee arthroplasty. To determine the reason for failure, describe the technical difficulties during revision surgery and record the clinical outcomes of the revision arthroplasties.

Methods

Between 2003 and 2009 our institute performed thirty three revisions of a unicompartmental knee arthroplasty on thirty two patients. The time to revision surgery ranged from 2 months to 159 months with a median of 19 months.

Details of the operations and complications were taken form case notes. Patient assessment included range of motion, need for walking aids and the functional status of the affected knee in the form of the Oxford knee score questionnaire.


Hafiz Iqbal Shoaib Iqbal Simon Barnes

INTRODUCTION

Hallux Valgus is a common foot condition, which may affect mobility and lifestyle. Corrective surgery is performed as a day case procedure, however, post-operatively; patients remain limited in their ability to drive for a variable period. In the laboratory settings, emergency brake response time after first metatarsal osteotomy has been studied but there is no published study of patients’ experience of driving after this surgery. This study was aimed at assessing patients’ driving ability and comfort after Hallux Valgus corrective surgery.

METHODS

Fifty consecutive patients who underwent first metatarsal corrective osteotomy from January 2009 to July 2010 were reviewed. The operation type, foot side operated, postoperative complications and other conditions affecting driving were recorded from charts and operation notes. A telephonic survey was then conducted and information was recorded in a predesigned questionnaire. The questions included driving advice given by the medical staff, time interval to begin driving postoperatively, and how long the patient took to gain full confidence at driving. It was also noted whether patients required changing the type of car from manual to automatic.


Jean-Yves Jenny François Saussac Pascal Louis

INTRODUCTION

Computer-aided systems have been developed recently in order to improve the precision of implantation of unicompartmental knee replacement (UKR).

Minimal invasive techniques may decrease the surgical trauma related to the prosthesis implantation, but there might be a concern about the potential for a loss of accuracy. Mobile bearing prostheses have been developed to decrease the risk of polyethylene wear, but are technically more demanding. Navigation might help to compensate for these difficulties.

We wanted to combine the theoretical advantages of the three different techniques by developing a navigated, minimal invasive, mobile bearing unicompartmental knee prosthesis.

MATERIAL AND METHODS

160 patients have been operated on at our institution with this system. The 81 patients with more than 2 year follow-up have been re-examined. Complications have been recorded. The clinical results have been analyzed according to the Knee Society Scoring System. The subjective results have been analyzed with the Oxford Knee Questionnaire. The accuracy of implantation has been analyzed on post-operative antero-posterior and lateral long leg X-rays. The 2-year survival rate has been calculated.


Ola Rolfson Roger Salomonsson Leif Dahlberg Göran Garellick

This randomised methodological study sought to test the reliability of an Internet questionnaire and investigate the differences in response rates between traditional pen-and-paper questionnaires and Internet questionnaires for measuring patient-reported outcome after total hip arthroplasty (THA) surgery.

From the Swedish Hip Arthroplasty Register, 2 400 patients were chosen at random but stratified by age, sex and diagnosis for inclusion in a four-year follow-up using the health-related quality of life (HRQoL) tool EQ-5D and visual analogue scales for pain and satisfaction. The patients were randomized to answer the follow-up model protocol either via a password-protected Internet questionnaire or via a mailed pen-and-paper questionnaire.

A reliability test for the Internet follow-up instrument showed adequate correlation. However, the Internet group and the pen-and-paper group differed significantly (p<0.001) with a 92% response rate in the latter and 49% in the former. Adjusted to the normal age distribution of the THA population, the Internet response rate was 34%.

The patient-administered Internet questionnaire alone does not give a sufficient response rate in the THA population to replace the pen-and-paper questionnaire. However, the system is reliable and could be used for measuring patient- reported outcome if supplemented with traditional pen-and-paper questionnaires for Internet non-respondents. It is expected that this answer procedure will soon predominate in view of the general development of Internet functions. Register work may then become less resource-consuming and the results may be analysed in real time.


Jean Yves Lazennec Jean Patrick Rakover Alain Aaron Hugues Pascal Mousselard Marc Antoine Rousseau

Introduction

Current artificial discs include 1 or 2 bearing surfaces, providing 3 or 5 degrees of freedom. The ESP® is a one-piece e implant made of silicon and polycarbonate -urethane securely fixed to titanium endplates. It allows limited rotation and translation with elastic return. This cushion without fixed rotation center achieves 6 degrees of freedom including shock absorption. This objective of this study was to evaluate the safety and efficacy of the concept in a prospective nonrandomized trial.

Material and methods

Prior to clinical implantations, the device was endurance tested at least 40 millions cycles. The polymer core weight and properties, the geometrical characteristics and cohesion of the implants remained stable.

A prospective trial was initiated in 2004 for L3L4, L4L5 and L5S1 levels. Total disc replacements have been performed in 153 lumbar levels through extra-peritoneal mini-invasive anterior approach with a minimum 2 years follow-up.


Samer Morgan Sherif Abdalla Andrew Jarvis

Introduction

Trends in hallux valgus surgery continue to evolve. Basal metatarsal osteotomy theoretically provides the greatest correction, but is under-represented in the literature. This paper reports our early experience with a plate-fixed, opening- wedge basal osteotomy, combined with a new form of distal soft tissue correction (in preference to Akin phalangeal osteotomy).

Materials and Methods

Thirty-three patients are reported here. The basal metatarsal osteotomy is fixed with the ‘Low Profile’ Arthrex titanium plate. No bone graft or filler is required, providing the osteotomy is within about 12mm of the base.

Distal soft tissue correction comprised a full lateral release, and then proximal advancement of a complete capsular ‘sleeve’ on the medial side. The plate serves as a rigid anchoring point for the tensioning stitches. Using this technique, almost any degree of hallux valgus can be corrected, and there is even potential for over-correction.

Functional outcome was assessed using the Manchester-Oxford foot and ankle score (MOXF). Radiographically the intermetatarsal angle was evaluated pre-operatively and at least 6 months postoperatively. Patients’ satisfaction and complication rates were recorded.


Aryan Dawoodi Anthony Perera

Background

Metatarsus adductus is the most common forefoot deformity. Variable prevalence values were reported in literature using different techniques in different populations.

Numerous radiological measurements have been proposed to assess this deformity with a paucity of studies reporting the reliability of these methods.

The metatarsus adductus angle was shown to correlate with the severity of hallux abductovalgus in normal feet and preselected populations of juvenile hallux valgus.

Materials & Methods

Weight bearing dorsoplantar radiographs of 150 feet were examined for 5 angles commonly used in assessing metatarsus adductus: angle between the second metatarsus and the longitudinal axis of the lesser tarsus (using the 4th or 5th metatarso-cuboid joint as a reference), Engel's angle and modified angle's angle. The prevalence of metatarsus adductus was assessed according to published criteria for different techniques. Inter and intra-observer reliabilities of these angles were evaluated on 50 X-rays. Linear regression tests were used to assess the correlation between hallux valgus and different angles used in assessing metatarsus adductus.


Joseph Arndt Yann Charles Ioan Bogorin Jean Steib

Introduction

Degenerative disc disease results from mechanical alteration of the intervertebral disc. Biochemical modifications of the nucleus matrix are also incriminated. Furthermore, genetic predispositions as well as vascular factors have been advocated in the process of disc degeneration. A relationship between sciatica and Propionibacterium acnes has been described. However, it remains unclear if the hypothesis of a subclinical spondylodiscitis might play a role in the pathophysiology of degenerative disc disease. The purpose of this study was to analyze the possible presence of bacteria in lumbar discs of patients with degenerative disc disease.

Methods

We prospectively analyzed the presence of bacteria in 83 patients (34 males and 49 females, average age 41 years) treated by lumbar disc replacement at L3-L4, L4-L5 or L5-S1. An intraoperative biopsy and microbiological culture were performed for each disc to determine if intradiscal bacteria were present. Great care was taken to avoid any source of contamination during the conditioning process of the biopsy. Microbiological results were compared to the magnetic resonance stages of disc degeneration according to the Pfirrmann and Modic classifications. Possible sources of previous iatrogenic disc contamination after discography or nucleotomy were analyzed.


Chang Qing Zhang Chang Qing Zhang Sheng Bao Chen Dong Xu Jin Jia Gen Sheng Wei Tao Jia Bing Fang Zeng

Background

Using one-stage bilateral free vascularized fibular grafting (FVFG) to treat avascular necrosis of the femoral head (ANFH) remains controversy due to potential high-risk and technical complexity. The purpose of the present study was to evaluate the safety and effectiveness of one-stage bilateral FVFG procedure versus unilateral FVFG in the treatment of ANFH.

Methods

One-stage bilateral FVFG was performed for 26 patients with bilateral ANFH between March 2001 and September 2006. The clinical and radiographic outcomes, hospital stays, and postoperative complications in this group were compared with those from another 33 patients (40 hips) receiving unilateral FVFG.


Shreedhar Aranganathan Shreedhar Aranganathan Sandesh Lakkol Razvan Taranu Guru Reddy Tai Friesem J Kang

Introduction

The implantation of DIAM in interspinous space is believed to act as facet joints and provides stability to operated segment by shifting instantaneous axis of rotation forward in lordotic disorders. In this retrospective study, the patients who underwent lumbar surgery with DIAM (Medtronic Sofamor, Danek) spacer implants were followed up with an aim to evaluate the clinical outcomes. To our knowledge, this is the largest series with longest follow up.

Material Methods

Patients who underwent lumbar surgery (discectomy and decompression) with concomitant placement of DIAM spacer within a 36-months period were included. A total of 52 patients including equal number of male (n=26) and female (n=26), were followed up for 12 to 45 months (Mean: 22 months).


Sebastien Lustig Nicolas Barba Elvire Servien Camdon Fary Guillaume Demey Philippe Neyret

To our knowledge in medial unicompartmental knee arthroplasty (UKA) no study has specifically assessed the difference in outcome between matched gender groups. Previous unmatched gender studies have indicated more favourable results for women.

Method

2 groups of 40 of either sex was determined sufficient power for significant difference. These consecutively were matched with both the pre-operative clinical and radiological findings. Minimum follow up of 2 years, mean follow-up 5.9 years. Mean age at operation was 71 years.

Results

In both groups, the mean IKS knee and function scores improved significantly (p< 0.001) post operatively. There were no significant differences were between the 2 groups. In both groups mean preoperative flexion was 130 degrees and remained unchanged at final follow-up. No significant differences in preoperative and postoperative axial alignment and in the number of radiolucent lines, between groups.

With component size used there was a significant difference (p < 0.001) between the 2 groups. However the size of the femoral or tibial implant used was significantly related (p< 0.001) to patient height for both sexes. Radiolucent lines were more frequent on the tibial component, but were considered stable with none progressing. No revisions for component failure. 1 patient in each group developed lateral compartment degenerative change.

Male group; one conversion to TKA for undiagnosed pain, three patients underwent reoperation without changing the implant. Female group; no implants were revised, and two patients required a reoperation. Kaplan-Meier 5-year survival rate of 93.46% (84.8; 100) for men and100% for women. The survival rate difference is not significant (p=0.28).


Fabio Ravaglia Maria Leite Tiago Barcellos Alberto Cliquet Junior

Background

Though less common than in females, osteoporosis and osteoporosis-related fractures are not uncommon in males. Our primary objectives were (1) to compare the rates of osteoporosis and osteopenia in adult Brazilian males versus females, 55 years old and over and presenting for bone mineral densitometry (BMD); and (2) to compare males and females as to past osteoporosis screening and management.

Methods

From our clinic population, we prospectively surveyed 343 males and 493 females, all at least 55 years of age, who had presented for BMD testing, to identify baseline demographic and clinical characteristics; risk factors for osteoporosis and osteoporotic fractures; overall osteoporosis and 10-year fracture risk; and evidence of prior assessment for and/or management/prevention of osteoporosis. Final osteoporosis risk was determined using the results of BMD testing and the FRAX® tool. Gender comparisons were performed using Pearson 2 analysis for nominal and ordinal variables, Student's t-tests for normally-distributed continuous variables, and Mann-Whitney U tests for non-normally-distributed continuous variables, with all tests 2-tailed and p=0.05 set as the threshold for statistical significance. Binary logistic regression was performed to identify predictors of prior hormonal treatment and BMD.


Joseph Arndt Philippe Clavert Frédérique Daemgen Jean Dosch Akli Moussaoui Cyril Penz Jean Kempf

Introduction

Latissimus dorsi transfer is a procedure used in massive irreparable posterosuperior rotator cuff tears, in young patient with severe pain and significant functional impairment. The purpose of this retrospective study was to evaluate its clinical, radiological and electromyographic results.

Methods

Forteen massive irreparable posterosuperior rotator cuff tears were performed with latissimus dorsi transfer between 2000 and 2008, and were reviewed at an average follow-up of 56 months and minimum of 19 months. Five transfers were primary reconstructions, and nine were revision surgeries. Patients’ mean age was 52.7 years. Clinical outcomes were measured by the Constant score, pain level, active range of motion, and strength. Osteoarthritis and acromiohumeral distance were measured on standardized radiographs. Ultrasound examination evaluate the integrity of the tendon. Axial images in CT-scan looked for muscle atrophy of latissimus dorsi in comparison with the controlateral. Electromyographic activity was measured during active flexion, abduction, adduction and rotations.


Sebastien Lustig Sebastien Parratte Elvire Servien Jean-Noel Argenson Philippe Neyret

Introduction

It is documented in the literature the very good results of lateral unicompartmental knee arthroplasty (UKA) when the standard accepted indications are followed. In our experience these indications can be extended to include post-traumatic osteoarthritis (OA) with malunion secondary to tibial plateau fracture. We report our results concerning 15 UKAs in these particular situations.

Material and methods

From 1985 to 2009, we performed 15 lateral UKAs in 15 patients for post traumatic OA secondary to malunion following a tibial plateau fracture. 7 were female and 8 male. The mean age of the patients at the time of the index procedure was 45±17 years and the mean delay from initial trauma was 5.4 years. The average follow-up was 108 months (range 12–265 months).


Jitendra Mangwani Matthew Cichero Sarah Irby Ben Yates David Williamson

Introduction

Venous thromboembolism (VTE) is an uncommon complication of foot and ankle surgery but has the potential for significant morbidity and mortality. The incidence, risk factors and prevention of VTE in foot and ankle surgery is not clear.

Materials and methods

We conducted a systematic review of the literature using MEDLINE, EMBASE, CINAHL, the Cochrane library and reference lists of retrieved articles without language or date restriction upto 31st July 2010. The Coleman methodology score was used to evaluate the quality of studies. From 985 citations, 38 full text articles fulfilled the inclusion criteria. Conclusions were drawn on the incidence, risk factors and prevention of VTE in foot and ankle surgery.


Robert Wendlandt Sebastian Schrader Arndt-Peter Schulz Sebastian Spuck Christian Jürgens Volker Tronnier

Introduction

The degeneration of the adjacent segment in lumbar spine with spondylodesis is well known, though the exact incidence and the mechanism is not clear. Several implants with semi rigid or dynamic behavior are available to reduce the biomechanical loads and to prevent an adjacent segment disease (ASD). Randomized controlled trials are not published. We investigated the biomechanical influence of dynamic and semi rigid implants on the adjacent segment in cadaver lumbar spine with monosegmental fusion (MF).

Materials and Methods

14 fresh cadaver lumbar spines were prepared; capsules and ligaments were kept intact. Pure rotanional moments of ±7.5 Nm were applied with a Zwick 1456 universal testing machine without preload in lateral bending and flexion/extension. The intradiscal pressure (IDP) and the range of motion (ROM) were measured in the segments L2/3 and L3/4 in following situations: in the native spine, monosegmental fusion L4/5 (MF), MF with dynamic rod to L3/4 (Dynabolt), MF with interspinous implant L3/4 (Coflex), and semi rigid fusion with PEEK rod (CD Horizon Legacy) L3-L5.


Nicolas Robial Yann Philippe Charles Ioan Bogorin Julien Godet Jean Paul Steib

Introduction

Surgical treatment of spinal metastasis belongs to the standards of oncology. The risk of spinal cord compression represents an operative indication. Intraoperative bleeding may vary, depending on the extent of the surgical technique. Some primary tumors, such as the renal cell carcinoma, present a major risk for hemorrhage and preoperative embolisation is mandatory. The purpose of this study is to evaluate the possible benefit of embolisation in different types of primary tumors.

Material and Methods

The charts of 93 patients (42 women, 51 men, mean age 60.5 years) who were operated for spinal metastasis, 30 cases with multiple levels, were reviewed. Surgical procedures were classified as: (1) thoracolumbar laminectomy and instrumentation, (2) thoracolumbar corpectomy or vertebrectomy, (3) cervical corpectomy. A preoperative microsphere embolisation was performed in 35 patients. The following parameters, describing blood loss, were evaluated: hemoglobin variation from beginning to end of surgery, blood volume in suction during the intervention, number transfused packed red blood cells units until day 5 after surgery. A Poisson model was used for statistical evaluation.


Asef Alani Grahame Taylor

Background

A pedobarograph is a device that records pressures exerted by the foot on contact with the ground. Clinically most publications using pedobarography investigated diabetic foot pressures for prevention of ulcers, and assessing gait and sway. Only limited work was done on the effects of foot surgery on foot pressures. Any comparison between papers is hampered by the absence of available defined normal ranges of foot pressures.

Aims of Study

The objective of the research project is to describe the foot pressures for 250 volunteers and to identify any trends and relationships of age, sex, body mass index (BMI), shoe & foot size and ethnic origin to foot pressures. The study is to provide a baseline upon which further comparative clinical research can be built.


Rob Bogie L Voss T Welting P Willems J Arts L Van Rhijn

INTRODUCTION

Surgical correction of spinal deformities in the growing child can be applied with or without fusion. Sublaminar wiring, first described by Luque, allows continuation of growth of the non-fused spine after correction of the deformity. Neurological complications and wire breakage are the main clinical problems during the introduction and removal of currently used sublaminar wires. In this pilot study a posterior hybrid construction with the use of a medical-grade UHMWPE (Dyneema Purity®) sublaminar wire was assessed in an ovine model. We hypothesized that such a hybrid construction can safely replace current titanium laminar wires, while providing sufficient stability of the non-fused spinal column with preservation of growth.

MATERIALS AND METHODS

This study included 6 Tesselaar sheep, age 7±2months. Two pedicle screws (Legacy system, Medtronic) were placed at lumbar level. Four consecutive laminae were attached to two titanium bars (4.5 mm) using 3 mm diameter UHMWPE (Dyneema Purity®) on the left side and 5 mm diameter on the right side. The sublaminar wires were fixed with a double loop sliding knot and tightened with a tensioning device. As a control, in one animal titanium sublaminar wires (Atlas cable, Medtronic) were applied. After sacrifice the spine of the animals was harvested. Radiographs were taken and CT scans were performed. The vertebrae were dissected and placed in formaldehyde for macroscopic and histological evaluation.


Morten Kristensen Henrik Kehlet

Purpose

Clinicians need knowledge about early and valid predictors of short-term outcome of patients with hip fracture, to adjust and plan rehabilitation. The concept of multimodal rehabilitation has proven effective. Still, some patients do not regain basic mobility independency in the acute orthopaedic setting. The aim was to examine the predictive value of age, sex, prefracture functional level, mental and health status, and fracture type of in-hospital basic mobility outcome, and discharge destination after hip fracture surgery.

Subjects

A total of 213 consecutive patients (157 women and 56 men) with a median age of 82 (25–75% quartile, 75–88) years, admitted from their own home, and following a multimodal rehabilitation concept, were included. Fifty percent of patients had a high prefracture functional level, evaluated by the New Mobility Score (NMS), 77 and 62% had respectively, a high mental and health status, and the distribution of cervical versus intertrochanteric fractures were equally divided.


Charles Bragdon John Martell Bryan Jarrett John Clohisy Richard White Victor Goldberg Craig Della Valle Daniel Berry Per-Erik Johanson William Harris Henrik Malchau

Introduction

Total hip replacements using highly cross-linked polyethylene show excellent clinical outcomes, low wear, and minimal lysis at 5 years follow-up. A recent RSA study reports a significant increase in femoral head penetration between 5 and 7 years. This study is a multi-center radiographic analysis to determine whether the RSA observation is present in a large patient cohort.

Methods

Six centers were enrolled for radiographic analysis of primary total hip arthroplasty for standard head sizes (26mm, 28mm, or 32mm). Radiographic inclusion criteria required a minimum of four films per patient at the following time points: 1 year; 2–4.5 years; 4.5–5.5 years; and 5.5–11 years. The Martell Hip Analysis Suite was used to analyze pelvic radiographs resulting in head penetration values. Wear rates were determined in two ways: the longest follow-up radiograph compared to the 1 year film, and individual linear regressions for the early and late periods. For both methods, average wear rates from the early period (1 to 5.5 years) and late period (>5.5 years) were compared using t-tests.


Byung Kii Cho Yong Min Kim

Introduction

This study was performed prospectively and randomly to compare clinical outcomes of modified-Brostrom procedure using single and double suture anchor for chronic lateral ankle instability.

Material & Methods

Forty patients were followed up for more than 2 years after modified-Brostrom procedure for chronic lateral ankle instability. Twenty modified-Brostrom procedures with single suture anchor and 20 procedures with double suture anchor randomly assigned were performed by one surgeon. The mean age was 30.6 years, and the mean follow-up period was 2.6 years. The clinical evaluation was performed according to the Karlsson scale and Sefton grading system. The measurement of talar tilt angle and anterior talar translation was performed through anterior and varus stress radiographs.


Andrey Iotov Vladimir Ivanov Nedelcho Tzachev Asen Baltov Danail Liliyanov Pavel Kraevsky Borislav Zlatev Dimitar Kostov

INTRODUCTION

Management of neglected residually displaced acetabular fractures is a big challenge. ORIF is often doomed to failure so a primary total hip replacement is usually kept in mind as a method of choice. However THR is a technically difficult and results are quiet unpredictable. OBJECTIVE. To present our experience with THR in maltreated grossly displaced acetabular fractures and to discuss operative technique and prognostic factors in that complicated surgery.

MATERIAL

THR was applied in 14 patients (11 males and 3 females, mean age 51 years) with at least three-months old and significantly displaced acetabular fractures. In 12 cases preceding treatment was conservative, and in 2 it was operative. Fracture nonunion was recognized in 5 cases, old hip dislocation in 4 and protusion in 3. Large interfragmentary gaps and local bone defect were detected in almost all cases.


Nils Hailer Erik Widerström Hans Mallmin

Introduction

Stiffness of the knee after total knee arthroplasty (TKA) impairs knee function and reduces patient satisfaction. Limited preoperative range of motion (ROM) and a diagnosis of osteoarthritis seem to be associated with postoperative stiffness, and medical comorbidities such as diabetes mellitus have been discussed as predisposing factors. The present study was undertaken in order to analyse both patient-related and surgical factors that could be associated with the need for mobilization under anaesthesia (MUA) after TKA.

Methods

We designed a case-control-study and extracted the study population from our local arthroplasty register. We identified all patients in our register that required MUA following primary TKA (n=35) and then randomly selected 4 control patients for each case of MUA. Incomplete medical records resulted in the exclusion of 18 patients, leaving 157 patients. Univariate analysis was used in order to investigate differences between the two groups with respect to demographics, pre- and postoperative ROM, medical or psychiatric comorbidities, and the type of implant. Variables with a proposed influence on outcome were entered into a binary logistic regression model, and risk ratios (RR) were calculated with 95% confidence intervals (CI).


Rajinder Singh Gaheer Jon Dillon Stuart Bell Rupert Ferdinand

Arthordesis of small joints of the foot is a commonly performed procedure in orthopaedics. A variety of fixation devices have been used for this purpose. Nickel-Titanium Memory compression staples for arthrodesis have been used in our institute since June 2003. We report the results of the procedure over a period of 7years involving 252 feet in 232 consecutive patients who underwent arthrodesis or an osteotomy fixation using compression staples. The patients were evaluated to determine the period of immobilization in cast and the time to radiographic joint fusion.

The emphasis of this study was to validate the safety of the implant for fusion of small joints of the foot, as well as to determine whether there is a demonstrable trend in time to fusion and period of immobilization required.

The average time to fusion was 7.2 weeks, the average period of immobilisation was 6.5 weeks. Successful union was achieved in 98% cases. We report the follow up results, finer technical aspects of the procedure and pitfalls to avoid whilst performing the fusions.


Eva Correa Joan Miquel Martinez Sara Anna Isart Ginebreda Ignacio Jordi Tapiolas Enric Càceres

Our aim is to evaluate life quality in patients with achondroplasia after lengthening.

We examined 17 patients (11 men and 6 women) who finished the complete lengthening process in the 3 segments (tibia, femur, humerus) more than 3 years ago. Mean age 30.35 years(17–44). And a final height of 152.3cm (140.4–169) with an increase in the size of the tibia of 15.38cm, femur 14.91cm and humerus 9.91cm

Life quality is assessed by the SF.36 test and a specific questionnaire for low size people.

The results show that the mental health component (52.2) and physical component (52.8) are similar to those of general American population. There is also a statistical correlation between the final height and better results on the Mental Health questions of SF.36 (p=0.013) and the psychological questions of the specific questionnaire (p=0.045).

Achondroplasic patients after lengthening have a standard life quality and the increase of their height improves the mental health aspects of life quality.


Eva Correa Jordi Font Xavier Mir Anna Isart Enric Cáceres

INTRODUCTION

The TFCC injuries are usually diagnosed by a coronal MRI. We have described the Float image for the diagnosis of peripheral injuries of the TFCC. In a sagital image parallel to the ulnar diaphysis and placed lateral to the ulnar fovea, we can observe the radiocubital dorsal and volar ligaments of the TFCC. A distance of more than 4mm between the dorsal edge of the meniscus and the joint capsule suggests the presence of TFCC peripheral rupture.

METHOD

51 pacients were selected from all the patients who underwent wrist arthroscopy between 2006–2009. Inclusion criteria: MRI at our hospital, arthroscopy at our hospital, no presence of radial fracture. We assessed the correlation between the presence of the Float image and a TFCC injury confirmed by arthroscopy.


Olivier Cantin Olivier Cantin Julien Chouteau Julien Henry Anthony Viste Michel-Henri Fessy Bernard Moyen

Introduction

There is a challenge to detect partial tear of the ACL, the number of bundle injured and the proportion of fibers torn. The MRI was shown efficient to individualize the two anteromedial (AM) and posterolateral (PL) bundles of the ACL. The purpose of this study was to assess the ability of the MRI to detect partial tears of the ACL on axial views to display the AM and PL bundles.

Materials and methods

This retrospective study included 48 patients (19 partial tears of the ACL, 16 complete rupture of the ACL and 13 normal knee) who underwent both arthroscopy and MRI examinations of the knee. The conventional MRI protocol included one sagittal T1- weighted sequence and 3 proton-density fat sat. The images from MRI were analysis by a radiologist specialized in musculoskeletal imaging who was blinding to the arthroscopic findings. The criteria for the analysis of MRI were divided into primary (those involving the ACL himself) and secondary signs (associated abnormalities). The primary signs included the horizontalisation of the ACL (ACL axis), the global ACL signal intensity and the signal intensity of each AM and PL bundle. The secondary signs included bone bruise, osteochondral impaction, popliteus muscle injury, medial collateral ligament injury and joint effusion. The ACL was classified as normal, partially or totally torn. The rupture of the AM and PL bundle was specified.


Frédéric Dalat Julien Chouteau Michel Henry Fessy Bernard Moyen

Introduction

Numerous types of graft can be used for revision of anterior cruciate ligament (ACL) reconstruction. The goal of our studies was to analyze mid term outcomes of revision of anterior cruciate ligament reconstructions conducted by means of ipsilateral bone -patellar tendon -bone (B-PT-B) transplant.

Materials and methods

We conducted a retrospective study on a consecutive series of 44 patients. All patients were operated on by the same senior surgeon in our institution between 2003 and 2009. All patients had undergone a first ACL reconstruction with B-PT-B transplant. They all had ACL revision under arthroscopic assistance and by means of ipsilateral B-PT-B transplant after a minimum of 18 months after primary surgery. At time of ACL revision, the mean patients age was 28 years (range, 17–49 years). The average postoperative follow up after revision was 55 months (range, 12–88 months). We had no patient lost to follow up. All patients were evaluated by an independent observer using IKDC scoring system and KT 2000.


Jean Louis Rouvillain Thomas Navarre Octavio Labrada Blanco Wael Daoud Emmanuel Garron Yann Cotonea

Introduction

Conservative treatment of Achilles tendon ruptures may lead to re-rupture. Open surgical repair entails a risk of skin necrosis or infection. Several percutaneous techniques have been used, like Tenolig® or Achillon®, but these techniques are costly and may be marred by wound healing problems. Ma and Griffith described a technique for percutaneous repair witch left the suture and the knot under the skin, thus reducing the risk for infection.

Material and Methods

From January 2001 to September 2006, we used this percutaneous treatment for 60 acute ruptures of Achille tendon. The repair was made under local anaesthesia, using a single or double absorbable suture. Postoperative care was 3 weeks immobilisation in a cast in equinus position with no weight bearing, followed by another 3 weeks in a cast with the ankle at 90° with progressive weight bearing.


Martin Clauss Simone Frunz Silke Pannhorst Artesch Arteschrang Thomas Ilchmann

Introduction

Primary stability of the Burch-Schneider ring (BSR) in case of acetabular revision is discussed controversial. In a retrospective two centre cohort study we analyzed the influence of the mode of screw fixation and the restoration of the center of rotation on migration, loosening and other radiographic parameters.

Material/Methods

Patients with a minimal radiographical follow-up of 2 years and suitable for EBRA analysis were included. In group 1 (46 patients) screws were placed through the cranial spherical part of the ring and covered by cement and cup, in group 2 (40 patients) screws were placed through the cranial flange. Preoperative bone defects were classified, the postoperative centre of rotation was determined. Changes of screws were recorded, migration exceeding >1mm was seen as significant.


Francois Lintz Denis Waast Guillaume Odri Anne Moreau Olivier Maillard Francois Gouin

Purpose

To investigate the prognostic effect of surgical margins in soft tissue sarcoma on Local Recurrence (LRFS), Metastasis (MFS) and Disease Free Survival (DFS).

Patients and Methods

This is a retrospective, single center study of 105 consecutive patients operated with curative intent. Quality of surgery was rated according to the International Union Against Cancer classification (R0/R1) and a modification of this classification (R0M/R1M) to take into account growth pattern and skip metastases in margins less than 1mm. Univariate and multivariate analysis was done to identify potential risk factors. Kaplan-Mayer estimated cumulative incidence for LRFS, MFS and DFS were calculated. Survival curves were compared using Log rank tests.


Mercedes Gómez-Galván Silvia Román Inmaculada Quirós Manuel Quiles

Hip fractures are common in the elderly. These people often had a history of multiple falls, and previous fractures. Fear of falling (FOF) have being reported in the follow-up of hip fractures.

Aims

To evaluate the FOF in patients just after hip fracture and before surgical treatment.

Material and methods

Prospective study of patients admitted in our hospital with hip fracture (subcapital, trochanteric and subtrochanteric). All patients were evaluated using the FES-I score for FOF before surgical treatment. Clinical and social data, previous history of falls, and fractures were recorded. Exclusion criteria were a score below 8 on the Minimental test on admission and previous hip fracture. Stadistical analysis were peformed using ANOVA, chi square and contingency tables.


Lizz Van Der Heijden Michiel Van De Sande M Nieuwenhuijse P Dijkstra

Background

Giant cell tumours of bone (GCT) are benign bone tumours with a locally aggressive character. Local recurrence is considered the main complication of surgical treatment and is described in up to 50% of patients. Intralesional curettage with the use of adjuvants like phenol or polymethylmetacrylate (PMMA) is recommended as initial treatment, significantly decreasing the risk of recurrence. However, risk factors for local recurrence in skeletal GCT have not yet been firmly established and a golden standard for local therapy remains controversial.

Objective

The identification of risk factors predisposing for an increased risk of local recurrence. In addition, different surgical techniques are compared to identify the optimal surgical approach for the identified risk factors.


Maria Nuotio Pekka Jokipii Hanna Viitanen Janne Jousmäki Heli Helminen Esa Jämsen Aila Mäki-Rajala Pirkko Jäntti

Introduction

In the orthogeriatric model of care, orthopaedic surgeons, geriatricians, anesthesiologists, physiotherapists and the nursing staff work together with the aim to optimize the outcomes of vulnerable older patients undergoing orthopaedic surgery. It is recommended that the orthogeriatric care of hip fracture patients should be based on systematic treatment guidelines. We describe here how operative and perioperative management of hip fracture patients changed between the first and the second year after initiation of orthogeriatric collaboration.

Method

Data on all patients aged 65 years or over and experiencing a hip fracture between September 1st 2007 and August 31st 2009 were prospectively collected in a Finnish hospital district with a total of 200,000 inhabitants. The patients were evaluated 4–6 months postoperatively at the geriatric outpatient clinic. Starting from the second year, geriatrician's rounds 2–3 times a week at the orthopaedic ward were provided. In addition, a systematic treatment protocol agreed by orthopaedic surgeons, geriatricians and anesthesiologists was introduced to the hospital staff responsible for the care of hip fracture patients.


Bjarke Viberg Jesper Ryg Jens Lauritsen Soeren Overgaard Ole Ovesen

Background

The treatment of femoral neck fracture with internal fixation (IF) is recommended in younger patients and has compared to arthroplasty the advantage of retaining the femoral head. A big problem with osteosynthesis is though failure. Finding predictors for fixation failure is still an ongoing process and osteoporosis has been suggested as a predictor.

Aim

To correlate bone mineral density (BMD) in regard to failure of IF in osteosynthesized femoral neck fractures.


Haroon Majeed Zdenek Klezl Rajendranadh Bommireddy

Introduction

The main symptoms in multiple myeloma are the result of skeletal destruction mainly the vertebral column. The current treatments for multiple myeloma include radiotherapy and chemotherapy but unfortunately it is still incurable. However, the symptoms and quality of life of these patients can be improved by cement augmentation which has gained popularity in the recent years.

Aim

To analyse the efficacy and safety of cement augmentation and to assess the survival and outcome of the patients with vertebral fractures secondary to multiple myeloma.


Radu Radulescu Adrian Badila Octavian Nutiu Robert Manolescu Cristian Nita Ciobanu Traian Ionut Japie Alexandru Papuc Dragos Radulescu

Aim

to compare the medium term clinical and functional results of total hip arthroplasty after intertrochanteric osteotomy and primary total hip replacement.

Material and methods

We compared 2 groups of patients: Group I-93 patients with total hip arthroplasty after intertrochanteric osteotomy and Group II-93 patients with primary total hip arthroplasty. The patients in the control group (Group II) were randomly chosen from the cases operated by the same surgical team using the same kind of implant like those in Group I. The osteotomies were of different types: medial displacement (27), varisation(19), valgisation (18), flexion(25), rotational (4). The demographic parameters were similar in the 2 groups. Technical intraoperative challenges were noted. The Harris Score was determined at 12 months and 3 years after surgery. Clinical and radiological check-ups were performed each year. The duration of each surgical procedure was recorded. Complications were noted during the entire follow-up. The mean follow-up was 77 months.


Haroon Majeed Amit Bishnoi Peter Howard

Introduction

There is no established evidence to support the use of drains after total knee replacement; however 94% of orthopaedic surgeons in UK routinely use closed suction drains. Haematomas can form with or without using drains, presence of which in addition may provide portal for infection and may increase blood loss. Blood group and save is routinely performed for every patient undergoing total knee replacement, however actual cross match and transfusion is needed for a small percentage of patients.

Aim

To compare the requirement for blood transfusion after total knee replacement with and without the use of closed suction drains and the cost analysis of performing routine blood group and save pre-operatively.


Philipp Lichte Philipp Kobbe Richard Sellei Mathias Knobe Hans Pape

Aim of the study

Aim of this study was to find out which factors influence the outcome after both column fractures of the acetabulum.

Methods

We performed a retrospective analyse of 115 patients with both column acetabular fractures. The period between the injury and follow-up ranges between 2 and 19 years, 5,7 years on average. The initial displacement, the presence of a dislocation of the hip and fractures of the femoral head were analyzed on the initial radiographs. Postoperative displacement was classified according the classification of Matta. The common classifications of Helfet (posttraumatic arthrosis), Ficat/Arlet (femur head necrosis) and Brooker (periarticular calcification) were used to radiologically classify the long term results. Statistics were performed by the Chi-square-test.


Henrik Palm Michael Krasheninnikoff Kim Holck Tom Lemser Nicolai Foss Steffen Jacobsen Henrik Kehlet Peter Gebuhr

Introduction

We implemented an exhaustive operative and supervision algorithm for surgical treatment of hip fractures primarily based on own previously published literature. The purpose was to improve supervision and reduce the rate of reoperations.

Materials and methods

2000 consecutive unselected patients above 50 years admitted with a hip fracture were included, 1000 of these prospectively after implementation of the algorithm. Demographic parameters, hospital treatment and reoperations within the first postoperative year were assessed from patient records.

The algorithm dictated the surgical treatment based on three objective patient parameters: age, new mobility score and fracture classification on pre-operative anterior-posterior and axial radiographs. Intra capsular fractures were treated with two parallel implants, a sliding hip screw, an arthroplasty or resection of the femoral head. Extra capsular fractures were treated with a sliding hip screw or an intramedullary nail. Supervision of junior registrars was mandatory for the prosthesis and intramedullary nail procedures.


Dariush Savadkoohi Babak Siavashi Seyyed Siamak Rezanezhad Mozhgan Seifi Mohammad Savadkoohi

Aim

To analyse our results after en-block resection of aggressive GCT during 20 years period.

Methods

We review 86 patients with skeletal GCT during the last 20 years, from 1990 until 2009, retrospectively. In the cases of latent and active type, extended curettage and bone graft or cement were our treatment of choice, while in aggressive ones we performed en block resection and reconstruction by fibular autograft (e.g. in distal part of radius) or fusion/hinge joint prosthesis (e.g. in GCT around the knee joint). We describe the recurrences, metastases and complications according to treatment.


Babak Siavashi Dariush Savadkoohi

Background

Femoral neck nonunion is a challenging problem. If it is not treated properly, it will be ended with a catastrophe because the victims are younger and active patients and missing hip joint will result in a handicapped like person. If the head is viable, the best treatment is valgus osteotomy. In the original technique, site of nonunion was not explored but in our technique, there is exploration and cleaning of nonunion site and after reduction of fragments, fixation and subtrochanteric osteotomy were done.

Materials and methods

Patients with established nonunion of femoral neck fracture entered in study. Inclusion criteria's were age under 60 years old, spherical head of femur without changing the density of it and femoral neck nonunion at least 6 months after fracture. Nonunion site was freshed and any hard ware was removed and head was reduced as possible and subtrochanteric valgus osteotomy to 150 degree was done and fixed with angle blade plate. Bone graft was not used. Patients were studied one year monthly for signs of union of fracture site and signs of avascular necrosis of femoral head.


Amin Amin Parnell Keeling Hanan Marafi Ryan Wellington John Quinlan

Hip fractures are a major cause of morbidity and mortality in the elderly and are thought to represent an increasing cohort of our patients. It is estimated that the cost of caring for each patient for their hospital admission is €10,000. There is significant regional and international variation in the incidence rates of such injuries, depending on age, sex and ethnic variations in populations. Recent Irish literature would suggest that the rates in Ireland are exponentially increasing while in the US the rate may be decreasing. The length of stay of such patients is also an important issue especially in the current economic environment. The aim of this study was to define the incidence of hip fractures in the South East. The aim was also to examine any changes to their length of stay that have occurred in a 11 years period.

Independent searches of the operating theatre register and the HIPE (hospital in-patient enquiry scheme) database were undertaken for the time period. Population data was obtained from central census office and the HSE South East offices.

The combined incidence of hip fractures in 2008 and 1998 was 96.06 and 100.90 per 100,000 respectively. The male to female ratio in 2008 was 1:2.67, while in 1998 it was 1:3.04. 13% of the patients in 2008 where under 65 years of age, while in 1998 this figure was 8%. In 1998 the mean length of stay was 17.15. By 2008 this had increased to 23.95 days. The dramatic increase in acute hospital length of stay over the period was estimated to have a burden of more than 14 million euros on health board fund.

This study provides data on a large patient group which is of paramount importance. Health service resources can be allocated appropriately in the future in terms of acute and step-down care based on this data set and results.


Bhavuk Garg Prakash Kotwal

Introduction

Scaphoid nonunions remain controversial with regard to optimal management. The objective of this article is to compare our clinical experience in the treatment of patients with scaphoid nonunion using distal radius non vascularised bone graft with that of iliac crest bone graft.

Material & Methods

We conducted a prospective randomized study comparing the clinical, functional and radiographic results of 42 patients treated for scaphoid nonunion using a non-vascularised bone graft from the dorsal and distal aspect of the radius (group I), relative to 46 patients treated by means of a conventional non-vascularised bone graft from the iliac crest (group II). All nonunions were stabilized with single Herbert screw.


Bhavuk Garg Prakash Kotwal

Introduction

Transscaphoid perilunate dislocation is a rare injury and therefore it is easily missed at the initial treatment. Once ignored, an alternative treatment such as proximal row carpectomy is indicated, but surgical outcome is not as good as that of an early reduction. Also late reduction (> 3 months) is not possible and needs extensive dissection. We present an alternative technique of staged reduction with better outcome.

Material & Methods

16 cases (14 males & 2 females) with neglected Transscaphoid perilunate dislocation (> 3 month old) were treated with staged reduction. In first stage an external fixator was applied across the wrist and distraction was done at 1mm/day. Second surgery was done through dorsal approach and we were able to reduce all the fractures & dislocations. Herbert screws and K wires were used for fixation.


Adriana Pemoff Cristina Alegri Marcelo Sicardi Hernan Blanchetiere Sebastian Balan Mariano Gitard Ana Douglas Price Horacio Caviglia

INTRODUCTION

Musicians' hand problems are as old as music itself. These problems involve functional motor disorders which have been underestimated by musicians, who do not want to accept the possibility of reducing their professional activity and doctors who are either not knowledgeable about musicians' characteristics or underestimate this artistic activity.

The aim of this study is to determine the causes of the pathologies instrumentalist musicians have, and their distribution according to age group, instrument and type of music, and thus infer the main risk factors in the occurrence of medical problems related to musicians' activity.

MATERIALS AND METHODS

We consider musicians those who devote themselves to the study, teaching and playing of a musical instrument. In Argentina there are about 50.000 instrumental musicians.

Since over 14 years the members of “Las Manos del Músico” have treated 574 musicians. The 84% of the medical problems related to the playing of the instrument. Ages are between 13 and 78 years.

The musicians treated belong to different conservatories, symphonic and popular orchestras. Each musician was studied with the same protocol, filled in by the same professional.

Variables such as type of music, age, sex, instrument, dominance andrelated variables were taken into account.


Thomas Pandorf Roman Preuss Markus Flohr Carsten Upmann

Introduction

In knee arthroplasty a ceramic component has several advantages: first, there is no ion release implying a risk for potential allergies. Second, the hardness of the material leads to a scratch resistance which ultimately reduces PE wear over time. In the past, ceramic components in knee applications were limited in the variety of design possibilities due to necessary thickness of the component resulting from the associated fracture risk of ceramics.

By the development of an alumina matrix composite material with increased mechanical properties it is possible to develop ceramic knee components which have nearly the same design as a metal component and use the same implantation technique as well as the same instruments. This offers the surgeon the opportunity to choose intraoperatively between metal or ceramic knee components. Extensive in-vitro testing shows that ceramic knee components achieve superior mechanical test results. The reliability of the components is proven by two different burst tests and a fatigue test for both a femoral and a tibial ceramic knee component.

Material and method

The mechanical proof-test was developed by subsequent steps of numerical load/stress analysis and design of an adequate mechanical test equipment. The procedure was organized as follows:

Oncologic: Analysis of relevant maximum in-vivo loading conditions

Analysis of the “boundary conditions”

Finite Element analysis: Identifying regions of highest stress concentration

Design analysis and accommodation if necessary

Development of an adequate mechanical test equipment which produces stresses comparable to the in-vivo conditions

Performing mechanical tests with ceramic femoral components

Validation of the test concept: comparison of test results and stress analysis

Assign “safety margin”,

Establish “proof test”


Chris Peach Naomi Davis

Introduction

It has been postulated that a mild clubfoot does better than a severe clubfoot no matter what treatment course is taken. There have been previous efforts to classify clubfoot. For units worldwide that use the Ponseti Method of clubfoot management, the Pirani scoring system is widely used. This scoring system has previously been shown to predict the number of plasters required to gain correction. Our study aimed to investigate whether the Pirani score gave an indication of longer-term outcome using tibialis anterior tendon transfer as an endpoint.

Methods

A prospectively collated database was used to identify all patients treated in the Ponseti clinic at the Royal Manchester Children's Hospital between 2002 and 2005 with idiopathic clubfoot who had not received any treatment prior to their referral. Rate of tibialis tendon transfer as well as the patient's presenting Pirani score were noted. Feet were grouped for analytical purposes into a mild clubfoot (Pirani score <4) and a severe clubfoot (Pirani score 4) category depending on initial examination. Clinic records were reviewed retrospectively to identify patients who were poorly compliant at wearing boots and bars and were categorised into having “good” or “bad” compliance with orthosis use.


Pietro Ruggieri Elisa Pala Andrea Angelini Gabriele Drago Matteo Romantini Carlo Romagnoli Andreas Mavrogenis Caterina Abati Mario Mercuri

Introduction

Dedifferentiated chondrosarcoma (D.C.) has a very poor prognosis. The efficacy of chemotherapy is still debated. Aim of this study was to evaluate the survival of patients with D.C. and to evaluate possible prognostic factors.

Methods

Between 1990 and 2006, 109 patients were treated for D.C.: 55 males and 54 females, mean age of 59.6 years. In 81 cases tumor was located in the extremities and in 28 cases in the trunk. The most frequent dedifferentiation was in osteosarcoma (53.2%) followed by spindle cell sarcoma (21%), malignant fibrous histiocytoma (13.8%), fibrosarcoma (6.4%). All patients received surgery and mostly, limb salvage with tumor resection and implantation of a megaprosthesis or allograft (65 patients). Chemotherapy was given to 43 patients.


Full Access
David Loveday Nick Geary

Introduction

Medial column insufficiency in patients with painful acquired flatfoot can be difficult to appreciate. The reverse Coleman block test is used in this study to predict medial column instability.

Methods

Patients who underwent a procedure for medial column insufficiency with use of the reverse Coleman block test pre-operatively were investigated. Weight bearing radiographs were used to determine the joints in the medial column contributing to the deformity and also to estimate the angle which the first ray must be depressed to re-establish hindfoot neutrality. The reverse Coleman block test corrects a mobile valgus heel to a neutral position by placing a block, of appropriate height, under the first metatarsal head. With the heel in neutral and the relative forefoot supination compensated the foot returns to a neutral anatomic position. Gender, age, complications and radiological outcomes were investigated.


Marc Nieuwenhuijse Carla Van Rijswijk Arian Van Erkel Sander Dijkstra

Objective

Comparison of clinical outcome after Percutaneous Vertebro Plasty (PVP) for Osteoporotic Vertebral Compression Fractures (OVCFs) between patients with and without Intra Vertebral Clefts (IVCs).

Background

PVP is a common treatment modality for painful OVCFs. Patients presenting with OVCFs with an IVC, also described as avascular necrosis of the vertebral body or intravertebral pseuadoarthrosis, are thought to represent a specific subgroup: filling the cleft might result in immediate and possibly superior pain relief due to stabilization of the excessive mobility associated with an IVC and the risk for cement leakage might be decreased due to its cavitational nature.


Azal Jalgaonkar Anita Mohan Rob Pollock John Skinner Steve Cannon Timothy Briggs William Aston

Percutaneous biopsies can lead to seeding of tumour cells along the biopsy tract.

Correct surgical management requires preoperative identification and excision of the biopsy tract at time of surgery. These tracts become increasingly difficult to identify with time, leading to risk of inadequate excision of the biopsy tract and recurrence of the tumour at the biopsy site. We conducted a prospective study involving 45 patients who had tissue biopsies for bone and soft tissue tumours between February and May 2008. All the biopsies were performed by consultant radiologist under ultrasound or CT guidance. Case note analysis, patient history and examination at the time of surgery were used to collect data. 23 of 45 patients had accurate identification of the biopsy tract by the surgeon at the time of excision. The mean time between biopsy and excision was 52 days (range 6–140). 22 of 45 patients had unidentifiable biopsy site, with the mean time between biopsy and excision being 98 days(range 13–164) p=0.0004(paired t test). All 4 patients who received post-biopsy radiotherapy had unidentifiable biopsy site tract (mean duration 104 days) and 11 of the 18 patients who underwent neoadjuvant chemotherapy had an unidentifiable biopsy tract (mean duration 108 days). We concluded that identification of biopsy site was more difficult after 50 days, especially in patients who underwent radiotherapy and chemotherapy.

Following this study, all the patients who had biopsies of tumours had the site marked with India ink tattoo. We, then prospectively reviewed 36 patients between July and September 2010 who underwent excision of bone and soft tissue tumours and had their biopsy sites marked with India ink tattoo. After needle biopsy, one drop of the dye was applied at the site of the biopsy. This was taken up by capillary action beneath the dermis and remained present until the patient returned for their definitive surgery. The biopsy site was easily identifiable by the patients and the operating surgeon in all 36 patients. The mean time between biopsy and surgery was 77 days (range 10–299 days). Tattooing of the skin enabled the surgeon to accurately excise the biopsy tract along with the tumour. We recommend this technique of tattooing of the biopsy site with India ink, as it is safe, easily recognisable and permits accurate excision of the tract (including the tattoo), therefore preventing biopsy tract recurrence.


Peter Bock Michael Pittermann

Background

Acquired flatfoot deformity goes ahead with a partial or complete rupture and thus insufficiency of the tibialis posterior tendon. We present the results of flexor digitorum longus transfer and medial displacement calcaneal osteotomy to reconstruct the acquired deformity.

Material & Methods

Twenty two patients (24 feet) with an average age of 58 (36–75) years were operated on for acquired flexible flatfoot deformity. Two patients had a bilateral procedure. Patients were seen pre-and postoperatively in order to evaluate following parameters: AOFAS hindfoot score, visual analogue scale for pain (0–10), the tarsometatarsal angle on lateral and ap standing x-rays, the cuneiform heights and talocalcaneal angle on lateral standing x-rays and subjective postoperative satisfaction score (1-worst to 5-best). Average time of follow-up was 24.7 months (12–48).


Chenxi Li Azad Hussain Pamu Joseph Amir Kamali

INTRODUCTION

One of the recent advances in the hard-on-hard hip arthroplasty is the development of a new material of diffusion hardened oxidised zirconium (DHOxZr). The DHOxZr material consists of a ceramic layer on the top surface which is supported by a thick oxygen diffusion hardened (DH) zone underneath. With the desired properties of metal substrate, ceramic surface and a gradient structure of the oxygen diffusion zone, the DHOxZr-on-DHOxZr bearing combination is expected to produce low wear and minimal metal ions. This can possibly address the concerns associated with metal hypersensitivity associated with metal on metal bearings and fracture risk associated with ceramics. The aim of this study was to evaluate the wear of DHOxZr-on-DHOxZr as a possible hard on hard bearing combination in hips.

METHODS

Three pairs of 50 mm DHOxZr prototype hip joint devices, each consisting of a DHOxZr modular head and a DHOxZr liner were wear tested in a ProSim hip joint simulator under standard testing conditions used by the Implant Development Centre (IDC), Smith & Nephew, Leamington Spa for 5 million cycles (Mc).

The flexion/extension was 30° and 15°. The internal/external rotation was ± 10°. The force was Paul-type stance phase loading, with a maximum load of 3 kN and a standard ISO swing phase load of 0.3 kN. The test frequency was 1 Hz. Gravimetric analysis was carried out at 0, 0.5, 1, 2, 3, 4 & 5 million cycles.

The lubricant was new born calf serum with 2 g/l sodium azide concentration diluted with de-ionised water to achieve average protein concentration of 20 g/l. Lubricant was changed every 0.25Mc during the first million cycles of the test and at every 0.33 Mc from 1 to 5Mc.


Bassel El-Osta Michelle Connolly Hassan Soueid Preyankhee Kumaralingam Kasseti Ravikumar Fathima Razik Anastasia-Stefania Alexopoulos

Introduction and aim

Avascular necrosis (AVN) of femoral head remains a major post-operative complication of the surgical fixation of femoral neck fractures (#NOF). In order to reduce the incidence of AVN following this type of fracture, the National Institute for Clinical Excellence (NICE) has stated that fixation must occur within 6 hours. However, there is a paucity of information concerning whether time to fixation influences the development of AVN. The aim of the present study was to assess whether time to fixation affects the development of AVN in patients aged under 60 who had sustained a fracture (#)NOF.

Methods

We looked retrospectively at 101 patients (61 female, 40 male aged under 60 (mean age 47 years) who were admitted to a multi-tertiary centre having sustained an intracapsular #NOF. The underlying co morbidity of the patient sample was varied, as was the mechanism of trauma, though in the majority of cases the cause was a simple fall. The time delay (TD) between the time of injury and the time of operation for each patient was determined.


Olivier Borens Thomas Buchegger Julia Steinrücken Andrej Trampuz

Objectives

The risk of infection after type III° open fractures is high (10–50%). Preemptive antibiotic therapy may prevent posttraumatic infection and improve the outcome. Recommendations about the type and duration of antibiotic vary among the institutions and it remains unclear whether gram-negative bacilli or anaerobs need to be covered.

In Europe, the most commonly recommended antibiotic is amoxicillin/clavulanic acid.

We retrospectively analyzed microbiology, characteristics and outcome of patients with open type III° fractures treated at our institution.

Methods

Between 01/2005 and 12/2009 we retrospectively included all type III grade open fractures of the leg at our institution classified after Gustilo (JBJS Am 1976) into type IIIA (adequate soft-tissue coverage of bone with extensive soft-tissue laceration or flaps), IIIB (extensive soft-tissue loss with periosteal stripping and bone exposure), and IIIC (requiring arterial injury repair). Demographic characteristics, clinical presentation, microbiology, surgical and antibiotic treatment and patient outcome were recorded using a standardized case-report form.


Dimitris Katsenis Dimitris Katsenis Alexandros Stathopoulos Dimitris Begkas Antonis Kouris Kostas Pogiatzis

PURPOSE

To evaluate the late radiographic and functional complications occurring after treatment of reverse oblique trochanteric fractures with the proximal femoral nail.

PATIENTS

This is a retrospective study which was conducted between October 2004 and October 2009. 55 patients with a reverse oblique trochanteric fracture were treated with the Gamma 3 nail. According to the AO classification, there were 36 type AIII-1, 8 AIII-2, 11 AIII-3 fractures. Closed reduction was achieved in all patients. The long gamma 3 nail was used in 34 fractures. The mean follow up was 18 months (range 9 to 32 months). The patients were evaluated clinically (Harris hip score) and radiographically.


John Galbraith Joseph Butler Adeel Memon Rosmary Murphy Mark Dolan James Harty JG Galbraith JS Butler AR Memon RT Murphy AM Dolan JA Harty

Aims

Falls are a common occurrence among hospital inpatients and can lead to injury, prolonged hospitalisation and delayed rehabilitation. There is major economic burden associated with this. Post operative orthopaedic patients have certain risk factors that predispose them to falls including decreased mobility, use of opioids and, in some cases, history of previous falls.

Methods

A Prospective cohort study with a historical control group was performed looking at falls before and after implementation of a Falls Prevention Program (FFP). A cost analysis of the intervention was then undertaken. Patient data, HIPE data and fall-incident report data were reviewed to identify fall-related injuries and related costs.


Stefano Zaffagnini Maurilio Marcacci Giulio Maria Marcheggiani Muccioli Paolo Bulgheroni Roger Berbig Dirk Holsten Koen Lagae Joan Monllau Ricardo Crespo Erica Bulgheroni

INTRODUCTION

The purpose of this study is to report results from a prospective multicenter study of a bioresorbable type I collagen scaffold used to replace tissue loss following irreparable lateral meniscus injuries.

METHODS

49 non-consecutive patients (33M/16F; mean age 30.5 yrs, range 14.7–54.7 yrs) with irreparable lateral meniscus tears or loss requiring surgical treatment were prospectively enrolled at one of 7 EU centers. 11 patients (22%) had acute injuries of the lateral meniscus, while 38 (78%) had prior surgeries to the involved meniscus. Implantation of the LCMI (now Lateral Menaflex) was performed arthroscopically using an all-inside suturing technique (FASTFIX) combined with inside-out sutures in the more anterior meniscus aspect. Forty-three patients were evaluated with a 2 to 4-year follow-up (FU); mean FU duration was 45 months (range, 33–53 m). Patients were evaluated clinically and by self-assessment using Tegner activity and Lysholm function scores, as well as the Visual Analog Scales (VAS) for pain, and a satisfaction questionnaire. Evaluations were performed pre-operatively, 6 months, 1 year, 2 and 4 years after surgery. X-ray and/or MR-images were taken pre-operatively, and at 1 year and 2 years after surgery.


Devendra Chauhan Mueedul Islam Ram Dharmarajan

About 81,000 total knee replacements are implanted in the United Kingdom annually. Conventionally pneumatic tourniquet and surgical drains have been used in total knee arthroplasty. However, no definite evidence or guidelines exist to support their use.

The present study aims to look for any difference in perioperative recovery and complications following use of pneumatic tourniquet and surgical drains in knee replacement surgery.

We retrospectively analysed 60 total knee arthroplasties performed by 3 different surgeons at our hospital during January 2007 to June 2010. A sample size of 20 patients in each group was evaluated. Group 1: used tourniquet and drain; Group 2: used tourniquet but no drain; Group 3: didn't use tourniquet but used drain. Data was collected and analysed using statistical means, t-test & analysis of variance.

Parameters compared were surgical (anaesthetic) time, mean postoperative haemoglobin at 24 hrs, blood transfusion rate, haematoma formation, wound infection, pain, deep vein thrombosis and infection at discharge. At 6 weeks clinical follow up letters were analysed.

Our results reveal that there is no significant difference in duration of surgery in either group. Use of tourniquets didn't improve on surgical time (123–133 minutes).

Our Local Hospital Pain Score was used (1 no pain, 2 mild, 3 moderate, 4 severe and 5 worst imaginable pain). No difference at discharge was seen in either group.

Similarly no difference was seen in either group with postoperative haematoma formation with one case (5%) in Group 1 and 3 respectively.

Although the immediate postoperative haemoglobin (Hb%) was comparable in all 3 groups, Group 3 patients received more blood transfusion compared to other groups based on clinical grounds. About 50 % of Group 3 needed blood transfusion compared to 10% in Group 1 and 5% in Group 2.

There was only one proven case of superficial infection at 6 weeks (Group 2) which responded well to antibiotics. There were 4 cases of cellulitis noted at 6 weeks (3 in Group 2 and 1 in Group 3) which responded to oral antibiotics. No deep infection was noted.

The mean hospital stay in hospital was 6.5 days in Group 1, 5.5 days in Group 2 and 8 days in Group 3. There was no difference in rate of post-operative deep vein thrombosis (5% in Group 1 and 3).

The present study with the use of tourniquet and surgical drain in total knee arthroplasty showed no significant difference in surgical time and incidence of postoperative haematoma, deep vein thrombosis. Pain score at discharge was comparable and so was the infection rate. Patients in Group 2 (used tourniquet but no surgical drain) had least hospital stay (mean 5.5 days) and least blood transfusion rate (5%). Decision to use pneumatic tourniquet & drain still lies with the operating surgeon. We recommend a randomised control study for further evidence.


Nicholas London David Hayes Craig Waller Jon Smith Rhys Williams

Introduction

Osteoarthritis (OA) represents a leading cause of disability and a growing burden on healthcare budgets. OA is particularly vexing for young, active patients who have failed less invasive therapies but are not yet candidates for arthroplasty. Often, patients suffering in this wide therapeutic gap face a debilitating spiral of disease progression, increasing pain, and decreasing activity until they become suitable arthroplasty patients. An implantable load absorber was evaluated for the treatment of medial knee OA in this patient population.

Joint overload has been cited as a contributor to OA onset or progression. In response, the KineSpring® System (Moximed, Inc, USA) has been designed to reduce the load acting on the knee. The absorber is implanted in the subcutaneous tissue without violating the joint capsule, thus preserving the option of future arthroplasty. The implant is particularly useful for young, active patients, given the reversibility of the procedure and the preservation of normal flexibility and range of motion.

Methods and Results

The KineSpring System was implanted in 55 patients, with the longest duration exceeding two years. The treated group had medial knee OA, included younger OA sufferers (range 31–68 years), with a mean BMI > 30kg/m2. Acute implant success, adverse events, and clinical outcomes using validated patient reported outcomes tools were recorded at baseline, post-op, 2 and 6 weeks, and 3, 6, 12 and 24 months post-op.

All patients were successfully implanted with a mean procedure time of 76.4 min (range 54–153 minutes). Mean hospital length of stay was 1.7 days (range 1–3 days), and patients recovered rapidly, achieving full weight bearing within 1–2 wks and normal range of motion by 6 weeks. Most patients experienced pain relief and functional improvement with 85% (35/41) reporting none or mild pain on the WOMAC pain subscale and 90% (37/41) reporting functional impairment as none on mild on the WOMAC function subscale at the latest follow-up visit (mean 9.3 ± 3.5 months). Clinically meaningful and statistically significant pain reduction and functional improvement were noted with baseline WOMAC pain scores (0–100 scale) improving from 42.4 to 16.1 (p<0.001) and WOMAC function (0–100 scale) improving from 42.0 to 14.7 (p<0.001) at latest follow-up. Patients reported satisfaction with the implant and its appearance.


Chrishan Mariathas Geraint Williams Giles Pattison Joanna Lazar Muhammad Rashied

Introduction

No previous studies have attempted to measure parental satisfaction and service quality in regards to paediatric orthopaedic service inpatient care. We performed a prospective observational study to assess parental satisfaction with the level of service provided for paediatric orthopaedic inpatient care in our unit.

Methods

We employed the validated Swedish parent satisfaction questionnaire to generate parental satisfaction data from 104 paediatric orthopaedic hospital inpatients between August 2009 and May 2010 (49 elective and 55 trauma paediatric orthopaedic admissions, median age range 2–6 years). Questions focused on eight domains of quality: Information on illness, information on routines, accessibility, medical treatment, care processes, staff attitudes, parent participation and staff work environment. Scores generated were a percentage of the maximum achievable for that quality index, for example 100% would correspond to a parent awarding all questions for that index the highest possible score.


Sofia Fernandes Rui Cerqueira José Fraga Tiago Barbosa João Oliveira António Moreira Gomes Cruz Vitor Caetano Pereira Mendes

Introduction

The sliding hip screw is the implant of choice for the operative treatment of stable trochanteric femur fractures. Surgeons have been using widely the four-hole side plate DHS (Dynamic Hip screw) with four bicortical screws, which allows adequate weight bearing after operation. However, there is lacking of scientific studies that support the use of such long plate and we question ourselves if we can accomplish the same results with the use of a smaller plate. The objective of this study is to compare the results accomplished with a four-hole and a two-hole DHS side plate in the treatment of transtrochanteric fractures.

Material and Methods

This study included 140 patients (43 male and 97 female) that had stable transtrochanteric fractures between 1/01/2005 and 31/12/2008 and were submitted to osteossynthesis with DHS side-plate. 32 (22.9%) were treated with a two-hole DHS (group DHS2) and 108 (77.1%) with four-hole. The fractures were evaluated according to the AO/OTA classification and Evans for stability. The fracture reduction was assessed according to Sernbo criteria and was recorded also patient demographics, fracture patterns and fixation, comorbilities, mortality rate, capacity of ambulation and complications.


Jerome Essig Christian Nourissat Gérard Asencio

The use of a total hip arthroplasty with alumina on alumina bearing couple should limit the risk of wear and secondary osteolysis. From June 1999 to December 2002, we have realised a continuous series of 265 ABGII cementless THA with Alumina bearing.

The average age was 58 years (22–78 years). The main causes were osteoarthritis (81%) and osteonecrosis (13%). The operation was performed through a posterior standard approach. In all cases, an anatomic cementless ABG II stem and an acetabular cementless ABG II cup were implanted. The bearing couple was always Alumina Biolox Forte with a 28 mm femoral head in 99% of cases. To date, 12 patients died and 17 patients were lost to follow up (6.4%). 224 patients (232 hips) had a regular clinical and radiological follow-up. The mean follow up was 8.5 years (5–11 years). 9 patients were revised for septic loosening (4cases), femoral fracture (4 cases) and inveterate dislocation (1 case). There was no aseptic loosening. The overall survival rate at more than 10 years is 96.6%. We deplore 2 cases of postoperative dislocation. In this series, we did not observe any breakage of ceramic implant. The clinical and functional outcome is good and stable over time with an average PMA score at 17.6 and an average Harris score at 97.3. 16 patients reported at least one or more episode of abnormal noise “Squeaking” type (6%). It is most often a mild noise and it occurs in a static bending position. This noise disappeared with time in 10 cases. It never necessitated a prosthetic revision. The radiological control does not show any wear. There is no evidence of acetabular or femoral osteolysis. The radiological implant fixation according to the Engh and ARA criteria was good and stable in all cases.

This series demonstrate that the implantation of an anatomic cementless HA arthroplasty with an alumina bearing in a young and active patient prevents the risk of wear and osteolysis and improves durability over time. The use of a 28 mm head does not increase the risk of instability and we did not observe failure of the ceramic implants.


Lars Engesaeter Haavard Dale Geir Hallan Jan Schrama Stein Lie

Introduction

Infection after total hip arthroplasty is a severe complication. Controversies still exist as to the use of cemented or uncemented implants in the revision of infected THAs. Based on the data in the Norwegian Arthroplasty Register (NAR) we have studied this topic.

Material and Methods

During the period 2002–2008 45.724 primary THAs were reported to NAR. Out of these 459 were revised due to infection (1,0%). The survival of the revisions with uncemented prostheses were compared to revisions with cemented prostheses with antibiotic loaded cement and to cemented prostheses with plain cement. Only prostheses with the same fixation both in acetabulum and in femur were included in the study. Cox-estimated survival and relative revision risks were calculated with adjustments for differences among groups in gender, type of surgical procedure, type of prosthesis, and age at revision.


Aron Adelved Anna Totterman Thomas Glott Jan Erik Madsen Olav Roise

Introduction

Displaced fractures in the sacrum are associated with other intra-pelvic organ injuries. There are some reports on short term outcome, however there is little knowledge about the long-term morbidity after these severe injuries.

Aims of study

Describe neurologic deficits in the lower extremities and impairments involving the uro-genital, bowel and sexual functions a minimum of 8 years after injury.

Compare the long-term results with our previously published results after one-year follow-up (1).


Cristina Alves Carol Oliveira M Murnaghan Unni Narayanan James Wright

Background

Primary dislocation of the patella is a common acute knee disorder in children, adolescents and young adults. While primary dislocation of the patella has traditionally been treated non-operatively, primary operative repair of the medial patella-stabilizing soft tissues has been popularized more recently and thought to reduce the risk of dislocation. However, several studies have shown substantial rates of redislocation with longer follow-up time, irrespective of treatment. The purpose of this systematic review was to compare operative and non-operative treatment for primary dislocation of the patella, regarding redislocation rates and symptoms.

Methods

Based on a systematic literature search of the medical literature from 1950 to 2010, three randomized and two quasi-randomized controlled clinical trials comparing surgical stabilization with non-operative treatment for patients with primary patellar dislocation were selected. The Risk of Bias Tool (Cochrane Handbook, 2008) was used to assess the quality of the studies included. Study results were pooled using the fixed-effects and random-effects models with mean differences and risk ratios for continuous and dichotomous variables, respectively. Heterogeneity across studies was assessed with Q test and I-square statistic. A sensitivity analysis was performed by assessing the change on effect size by eliminating each single trial.


Anette Liljensoe Jens Ole Laursen Inger Mechlenburg

Purpose

The purpose of this study were to investigate whether there is an association between the preoperative body mass index in total knee replacement patients and the effect three to five years postoperative.

Method

197 patients who had undergone primary total knee replacement in the period 1.1.2005–31.12.2006 participated in a three-five years of follow-up study. Outcome measures were self-rated health (SF-36), which consists of eight strands and two component scores, physical component score and mental component scores and the Knee Society rating system (KSS) (knee score and function scores), and improvement of the two KSS scores from baseline to follow-up.


Laurent Angibaud Bernard Stulberg Jay Mabrey David Covall Albert Burstein Jason Steffens Hani Haider

Introduction

A tibial insert with choices in size, thickness, and posterior slope is proposed to improve ligament balancing in total knee arthroplasty. However, increasing posterior slope, or the angle between the distal and proximal insert surfaces, will redistribute ultra-high molecular weight polyethylene (UHMWPE) thickness in the sagittal plane, potentially affecting wear. This study used in-vitro testing to compare wear for a standard cruciate-retaining tibial insert (STD) and a corresponding 6° sloped insert (SLP), both manufactured from direct-compression molded (DCM) UHMWPE. Our hypothesis was slope variation would have no significant effect on wear.

Methods

Two of each insert (STD and SLP) were tested on an Instron-Stanmore knee simulator with a force-control regime. The gait cycle and other settings followed ISO 14243-1 and -2, except for reference positions. The STD insert was tilted 6° more than the SLP insert to level the articular surfaces. Wear was gravimetrically measured at intervals according to strict protocol.


L Zagra C Champlon V Licari R Ceroni

BACKGROUND

Many patients who underwent a THA, report a feeling of more “physiological” hip and of faster recovery when bigger heads are used. The aim of this study is to evaluate the walking recovery of patients after THA with different head diameters by the means of gait analysis.

MATERIALS AND METHODS

A prospective, randomized, blind study was conducted on 60 patients operated by THA at our Institution. Inclusion criteria were: primary hip arthritis, women, age between 55 and 70 years. Exclusion criteria were: other problems influencing walking ability (previous operations of the lower limbs, spine disorders, knee or controlateral hip arthritis). The same uncemented stem, same uncemented press-fit cup, same surgical technique and approach (posterolateral), same surgeons, same postoperative protocol and rehabilitation were employed. The only difference was the head diameter. The patients were randomized into three groups, of twenty patients each one (28mm Cer-on-XPE, 36mm Cer-on-XPE, >42mm Met-on-Met). The gait evaluation have been performed at three temporal steps: preoperatively, two months postoperatively and four months postoperatively. Kinematic parameters were acquired with Elite opto-electronic system (BTS, Milan, Italy) equipped with 6 cameras at 100 Hz frame rate. The system is integrated with a force platform (Kistler, CH) and a synchronic video system using two cameras (BTS, Milan, Italy). Data acquisition and processing were carried out using passive markers positioned according to Davis protocol. At least ten trials for each session were collected in order to assess the repeatability of the results. Gait analysis included kinematic parameters (temporal-spatial parameters and joint angular values) and kinetic parameters (ground interaction forces during walking). Articular moments and powers were computed on the basis of data obtained from dynamometric platform along with those given by kinematic analysis. All patients were compared to a control group. Wilcoxon signed rank test was employed for statistical evaluation.


Henri Migaud Emmanuel Marchetti Donatien Bocquet Nicolas Krantz Charles Berton Julien Girard

Introduction

The prosthetic impingement occurs if the range of motion of the hip exceeds implant mobility or in case of component malorientation. This retrieval study was designed to assess the frequency and the risk factors of this phenomenon.

Material and Methods

The frequency and the severity of the impingement were calculated from a continuous series of 311 cups retrievals collected between 1989 and 2004 by a single surgeon. The reason for retrieval was loosening (131 cases), infection (43 cases), instability (56 cases), osteolysis (28 cases), unexplained pain (48 cases) and prosthetic impingent (5 cases all with hard bearings). The notching at the cup rim was assessed twice by two examiners with optic magnification. The risk factors were analyzed from clinical charts by univariate and cox multihazard.


Mitchell Bernstein Nicholas Desy Olga Huk David Zukor Alain Petit John Antoniou

Introduction

Metal-on-metal (MoM) articulations in total hip replacement (THR) have become an attractive option for young, active patients. Short-term reports have demonstrated elevated systemic metal ion levels in the blood and urine. Disseminated concentrations of cobalt and chromium have raised concern regarding cellular toxicity, chromosomal damage and adverse local soft tissue reactions.

Long-term studies are required to support the increased use of MoM bearings in younger patients given their potential deleterious effects. The purpose of the current study was to report the 7–13 year clinical, radiographic, and metal ion results in patients following MoM THR.

Methods

We prospectively followed 165 patients (196 hips) after second-generation MoM THR between July 1997 and November 2003. Functional outcome was measured using the Harris Hip Score (HHS) and the University of California Los Angeles (UCLA) Activity Score. Radiographic analysis was performed using Einzel-Bild-Roentgen-Analyse (EBRA) by two of the authors blinded to the study. Cobalt and chromium metal ions were measured from whole blood and analyzed using inductively coupled plasma-mass spectrometry.


Henri Migaud Emmanuel Marchetti Antoine Combes Jean Puget Jacques Tabutin Yannick Pinoit Philippe Laffargue

Introduction

The same cup orientation is classically applied to all cases of hip replacement (45° abduction, 20° anteversion). We hypothesize that this orientation must be adapted to the patient's hip range of motion. We tested this hypothesis by means of an experimental study with respect to hip range of motion, comparing the classical orientation (45° and 20°), and the orientation obtained with computer-assisted navigation.

Material and Methods

The experimental model included a hemipelvis equipped with a femur whose mobility was controlled for three configurations: stiff (60°/0°, 15°/10°, 10°/10°), average (80°/10°, 35°/30°,35°/25°), mobile (130°/30°, 50°/50°, 45°/35°). The hemipelvis and the cup holder were equipped with an electromagnetic system (Fastrack ™) to measure cup orientation. The Pleos™ navigation system (equipping the hemipelvis, the femur, and the cup holder) guided the cup orientation by detecting the positions risking impingement through a kinematic study of the hip. Nine operators each performed 18 navigation-guided implantations (162 hip abduction, anteversion, and range of movement measurements) in two series scheduled 2 months apart.


Full Access
Gershon Volpin Tim Yacovi Leonid Lichtenstein Genadi Kirshner Bernard Grimberg Haim Shtarker Alexander Kaushanski Zack Stolero

INTRODUCTION

In recent years the age of world's population has risen and with it there has been a significant increase in the frequency of hip fractures in the elderly. These fractures are known to increase morbidity and mortality. However, little is known about the frequency and characteristics of patients who sustain a second hip fracture. We examined the incidence and the underlying associated medical disorders of patients with a second fracture in the other hip.

MATERIAL & METHODS

This study consists of 132/1208 Pts. (10.9%) treated in our department between 1998–2006 that had a secondary hip fracture 1–9 years following the first hip fracture. We examined the most common complications following surgery of this type, the most common related illnesses among these patients, and the influence of post-surgical rehabilitative care on the patients' return to daily functioning.


Ana Torres M Fairen Antonio Mazon Antonio Asensio A Meroño Agustin Blanco J Ballester

Between July 2000 and December 2002, 263 consecutive patients across 5 surgical centers underwent to a revision surgery of a failed acetabular component in which TM acetabular components were used.

There were 150 women and 113 men with a mean age of 69.5 years.

The indication for acetabular revision was aseptic loosening in 186 cases (70.7%)

Clinical evaluations were performed using the Harris hip score, the WOMAC and UCLA activity scale.

Implant and screw position, polyethylene wear, radiolucent lines, gaps, and osteolysis were assessed. Preoperatively, acetabular bone deficiency was categorized using the classification of Paprosky et al.

Statistical analysis was performed using nonparametric correlations. Standard life table was constructed, and the survival rate was calculated by means of Kaplan-Meier method.

The overall mean follow-up was 73.6 months (range, 60–84 months), and no patient was lost to follow-up.

The preoperative HHS rating improved from a mean of 43.6 ± 11.4 before revision, to a mean of 82.1 ± 10.7.

None of the patients was re-revised for loosening. The cumulative prosthesis survival was 99.2% at 5 years.

There was no correlation found between the various degrees of acetabular bony defect and the magnitude of clinical results (independent of pre-revision Paprosky grade). The use of component augments allowed us to minimize the volume of morsellized allograft used for defect repair.

TM acetabular component demonstrates promising midterm results similar to those reported by other authors.


Ludwig Kohn Knut Beitzel Gebhart Meidinger Ingo Banke Marina Münch Insa Beermann Andreas Imhoff Philip Schöttle

Objective

Overviewing the literature, pain and redislocation after surgical treatment of patellofemoral instability (PFI) is described with up to 30 %, especially with techniques involving the extensor mechanism, the lateral retinaculum or the medial vastus. However, outcome data about revision surgery is missing. Therefore, it was the purpose of this prospective study to evaluate the clinical outcome after revision surgery with an isolated or a combined reco. of the medial patellofemoral ligament (MPFL) with a follow up of 12 months. The indication for additional procedures such as distal femoral osteotomies (DFO), trochleoplasty, reclosing of the lateral retinaculum (RLR) or lateralisation of the tuberosity (LT) were performed depending on the clinical and radiological pathomorphologies.

Methods

In between 3/07–4/09, 42 pat. with a mean age of 24 years (13–46ys) were revised due to persistent PFI after mean 1.8 failed previous operations (lateral release, medial gather/VMO-distal., medial. of the tuberosity) in our department. An isolated reco. of the MPFL was performed in 15 cases, while a combination with a DFO due to massive femoral axis deformity (n=5), trochleoplasty due to a convex trochlear morphology (n=1) and/or LT (n=4) and/or RLR due to medial instability or lateral pain (n=22) was done in 27 cases. The clinical result was evaluated by the pre- and postop. IKDC/Kujala/Tegner-score and by a subjective questionnaire. Radiologically, the patellashift/-tilt/-height and level of the eventual degeneration were defined preop. and at the point of follow up with the help of straight lateral radiographs and by MRI. Significance level was set at p=.05, statistical calculation was done by the use of the t-test.


Santiosh Baliga Carol Carnegie Alan Johnstone

Introduction

Several clinical and radiological studies have confirmed the benefits of using Volar Locking Plates (VLPs) to treat unstable distal radius fractures. The “theoretical” advantage of VLPs compared to standard plate fixation is that VLPs, through their design, intrinsically provide angular stability for most fracture configurations including comminuted fractures and, quite possibly, osteoporotic fractures. However few studies have compared the clinical results of patients of different ages who have been treated using VLPs.

Aim

The aim of this study was to compare the clinical outcomes of VLP fixation of displaced distal radius in younger (<59 yrs) and older (>60yrs) patients.


Gaetano Pagnotta Dario Mascello Leonardo Oggiano Alessandra Novembri Alessandro Pagliazzi Barbara Bernocchi Gherardo Pagliazzi

Actually conservative treatment and/or minimal invasive surgical approach is considered the gold standard in the treatment of CF all around the world.

Two main italian pediatric hospitals (Bambino Gesù in Rome and Meyer in Florence) will present own series in order to realize how the two methods (Ponseti in Rome and Seringe in Florence) can be used, the right indications for each method and sharp limits as well.

The aim of this study is to compare two methods for evaluating their effectiveness and their applicability.

Patients, Methods and Results

Rome series: from 1998 to 2009 pediatric hospital Bambino Gesù in Rome had treated 1350 patients with the Ponseti method (1980 feet).

All feet had been scored according to Pirani classification.

At age of 3–4 months, the 72% of feet treated had minimal surgery consisted in transversal tenotomy of achille's tendon. Casting for further 3 weeks and Denis-Brown splint wore full time until walking age and during the night only for 3 years after walking age.

Surgery had been performed in 72% of case and surgery has been directly related to CF severity.

Florence series: the Unit of Pediatric Orthopaedics Meyer Children's Hospital of Florence was born in January 2004 and therefore the series includes patients from January 2004 to December 2009.

173 patients (239 feet) were treated. Dimeglio's classification was used. At the age of 4–5 months were treated with tenotomy of Achille's tendon 51,9% of patients, mainly stage 3, and immobilization in long leg cast was used only for three weeks after surgery.

Discussion

Minimally invasive treatment for CF is universally considered one of the best way to correct the deformity without using the extensive surgery that often causes stiffness, pain and shoes discomfort in adulthood.

The long-term results of two series are similar and this enhance our mind that not invasive method for CF treatment is effective, low-cost, with very low rate of recurrence, only if applied following strictly the protocol. In our series in fact the highest rate of recurrence concerns the missing of Denis-Brown device or early dismission of Denis-Brown as well.

The adherence to the protocol is chiefly recommended by the authors when surgery is not performed and therefore the risk of recurrence is higher.

The French method especially needs a skill panel of physical therapist that are in confidence with the bandage manoeuvres.

Only medical operators in confidence with the methods are able to guarantee good results and a low rate of recurrence as well. For this reason the method recommended by Dr. Seringe is easy exported in geographic areas where health service and health support are well represented.


Suresh Thomas R Bhattacharya J Saltikov D Kramer

Background

Injury to the ACL is a significant problem and can cause further damage to the internal structures of the knee. ACL injury is associated with injuries to other structures in the knee such as the meniscus and chondral cartilage. Such intra articular injuries pre-dispose the knee to develop arthritis. This injury is usually seen in young and active people usually related to sporting injuries. There is a paucity of literature on the influence of anthropometric features on the hamstring graft obtained in ACL reconstruction, although there are studies on the sex based differences affecting the hamstring graft. This study was undertaken to assess the influence of anthropometric measurements on the graft thickness obtained at ACL reconstruction surgery within the UK population.

Objective

This study was undertaken to assess the influence of anthropometric measurements (body mass index (BMI), height and weight) on the graft thickness obtained at anterior cruciate ligament reconstruction surgery.


Thomas Heyse Dan Chen Natalie Kelly Friedrich Boettner Timothy Wright Steven Haas

Introduction

Oxidized zirconium (OxZr) is used as a ceramic surface for femoral components in total knee arthroplasty (TKA). The aim of this study was to investigate its performance by examining retrieved femoral components and their corresponding PE inserts in matched comparison with conventional chrome/cobalt/molybdenum alloy (CrCoMo).

Methods

11 retrieved posterior stabilized (PS) TKA with an OxZr femoral component were included. From a cohort of 56 retrieved TKA with CrCoMo femoral components, pairs were matched according to duration of implantation, patient age, reason for revision, and BMI. The retrieved tibial polyethylene (PE) inserts were analyzed for wear using the Hood classification. Femoral components were optically viewed at 8–32x magnification and screened for scratching, pitting, delamination, and striation. Profilometry was performed to measure surface roughness of the OxZr components using a non-contact white light profiler.


Ertugrul Aksahin Ahmet Guzel Halil Yuksel Levent Celebi Aysun Erdogan Cem Aktekin Ali Bicimoglu

Aim

The purpose of this study was to analyze the patellofemoral kinematics in neglected adult developmental dysplasia of the hip patients with patellofemoral symptoms and tried to clarify the affect of the severity of dislocation, the amount of limb length discrepancy, the deviation of mechanical axis and the changes in femoral anteversion on patellofemoral alignment.

Methods

The dynamic patellofemoral CT results of 39 patients with DDH suffering from knee pain were reviewed. The mean age was 40.07 (range: 22–61). 14 of them were bilateral and 25 were unilateral neglected DDH patients. The CT results of 12 patients suffering from unilateral patellofemoral pain following the treatment of locked intramedullary nailing was taken as control group. In this patients atraumatic and asymptomatic normal site was taken as control group.


Julian Gaskin Bassel El-Osta Laszlo Zolczer

Introduction

Neonatal fractures are often quite distressing to parents and medical teams involved. Their management can be daunting due to the small size of the patient, the concern of the new parents and the fear of the obstetric staff about litigation and deformity or long term disability of the neonate.

Aim

This study assesses the radiological and functional outcome of neonatal fractures up to two years post injury.


Alberto Nicodemo Giorgio Governale Alessandro Stucchi Angiola Valente Claudio Cuocolo Alessandro Massè

Introduction

Between 2002–2009 we operatively treated 193 acetabular fracture. Among these 44 both-columns fractures according to the classification of Letournel and Judet have been reviewed in order to evaluate the results. These fractures are rare, difficult to treat and often have poor clinical results.

Patients and Methods

44 cases of ORIF of displaced both columns fractures have been studied at a mean 37 months follow-up (range, 13 to 76 months) after the injury. 40 hips were operated with the ilioinguinal approach alone, 1 with Kocker Langenbeck and Smith petersen combined. The 3 remaining hips were operated with a double Kocher-Langenbeck and ilioinguinal approach. Every case was evalueted on X-rays according to Matta criteria and clinically with the Harris hip score and the WOMAC score.


Gebhart Meidinger Ingo Banke Ludwig Kohn Marina Muench Insa Beermann Knut Beitzel Andrea Imhoff Philip Schoettle

Objectives

For a long time lateral release (LR) was performed as a standard procedure both, for patellofemoral pain syndrome (PFPS) and patellofemoral instability (PFI). However, recent biomechanical studies have shown that LR is not useful for decreasing the lateral force onto the patella, but is increasing not only medial but also lateral PFI. Furthermore, pain on palpation over the lateral patellofemoral joint space can result in patients treated with extensive LR. We postulate that in case of persistent PFI or PFPS after failed LR the reconstruction of the lateral retinaculum as an addition of the reconstruction of the medial patellofemoral ligament (MPFL) is necessary in terms of decreasing medial PFI as well as lateral pain.

Materials and Methods

In between 03/07 and 04/09 we have seen a total of 25 patients (20 f, 5 m) with persistent PFI and palpatory pain over the lateral retinaculum due to unsuccessful treatment of PFI with a LR. These patients have undergone revision surgery with an anatomical reconstruction of the released lateral retinaculum in combination with a reconstruction of the medial patellofemoral ligament (MPFL) in an aperture-technique using the gracilis tendon. The average age at time of operation was 26.2 ± 9.8 years. Preoperatively, as well as 6 weeks, 3 months, 6 months, and 12 months postoperatively, clinical examinations were performed and subjective as well as objective scores (Kujala-, Tegner-, IKDC-score) were evaluated. Regarding radiological parameters measurement of patellar tilt and shift was carried out on axial radiographs before and after the operation.


Mohammad Zafar Mohammad Zafar Anirudh Gadgil

Background

Symptomatic flexion deformity of proximal interpahalangeal joint (PIPJ) is one of the most common foot deformities and usually treated with arthrodesis. In general, percutaneous K-wires are used to stabilize the joint after excision of cartilage. K-wires projecting out of the toe need special care and can occasionally be dislodged accidentally. Furthermore issues such as cellulitis, pin tract infections, rarely osteomyelitis and need for removal make alternative fixation methods desirable. Smart toe is an intra-osseous titanium memory implant, which is stored frozen. It expands on insertion and does not require removal.

Methods

30 consecutive K-wire PIPJ arthrodesis were compared with 30 Smart toe PIP fusions with a mean follow up of 6 months. Post operative forefoot scores and complications were documented.


Remy Philippot Jean Philippe Camilleri Bertrand Boyer Frederic Farizon

The concept of stainless steel dual mobility cups in total hip arthroplasty has demonstrated very low long-term instability rates and a 98% survival rate after 12 years. We systematically implanted titanium alloy acetabular cups during a one year period. The purpose of our retrospective study was to report the 18-year clinical outcome data in a homogeneous and continuous series of 103 primary total hip replacements after implantation of a cementless titanium cup.

All patients were implanted with NOVAE Ti (SERF) cups made of titanium alloy combined with a retentive polyethylene liner and a 22.2 mm cobalt chrome prosthetic head. Mean patient age at the time of surgery was 53 years. All patients were clinically and radiographically evaluated.

The overall 18-year actuarial cup survival rate with a 95% confidence interval was 87.4%. At last follow-up, there was no evidence of implant instability whereas acetabular aseptic loosening was reported in one case and high wear of the retentive liner in 9.

The results of this investigation confirmed the long-term stability of dual-mobility implants. The main limitation of this system was early wear of the polyethylene liner in contact with the titanium metal back and reaction with third body along with loss of liner retentivity. In our study, titanium demonstrated favourable osteointegration properties but poor tribologic characteristics, therefore suggesting its interest at the bone-cup interface only.


Remy Philippot Bertrand Boyer Loic Schneider Frederic Farizon

Dual mobility significantly reduces the risk of prosthetic instability. This mechanical complication occurs when the prosthetic head moves out from the retentive polyethylene liner, such phenomenon called intra-prosthetic dislocation reports a ten-year incidence of 2% in the literature.

We prospectively analysed all intra-prosthetic dislocations having occurred since 1985 in our department in order to investigate patient- and implant-related risk factors.

91 intra-prosthetic dislocations occurred with NOVAE (SERF) cups in 85 patients of mean age 50.7 years. Intra-prosthetic dislocation occurred after a mean period of 8.8 years.

A PRO (SERF) stem was implanted in 56 cases and a PF (SERF) stem in 35. The stems were different from one another in their neck diameter and material: 13 mm titanium neck and 16 mm stainless steel neck respectively.

When taking both prosthetic features into account, no significant difference could be established regarding the time between implantation and dislocation.

Comparison between these two prosthetic features was performed by means of two continuous homogeneous series which included 240 patients implanted with PF stems and 382 patients with PRO stems. At a mean 15-year follow-up, the two series reported a non-statistically different intra-prosthetic dislocation rate of 4%.

In both series, young age and large diameter cups were considered predisposing factors for intra-prosthetic dislocation.

Therefore, unlike suggested by several authors, prosthetic neck material and diameter do not appear as the main predictors for intra-prosthetic dislocation which is highly promoted by patient-related features.


N Rumyantsev

Objective

In many institutions, serial casting and splinting requires many weeks of treatment and frequently results in surgery. This study evaluated the results of neonatal clubfoot correction with the Furlong method. This method was created by Furlong M.B. and Lawn G.W. in New York and was published in Archives of Pediatrics in 1960.

Materials and Methods

This study reviews 95 neonates with 128 severe clubfeet (initial Pirani score 4,0 or more). Patients with arthrogrypotic clubfeet and other syndromes were not included. Age at presentation ranged from 4 hours to 18 days. All patients had no previous treatment. The cast application with extra space above the foot was performed as follows: a special elastic pad was placed on the dorsal aspect of the foot and fixed with a cotton bandage. Then plaster cast was applied with knee flexion 110–120 degrees. After the cast was set, the elastic pad was removed, leaving a reserve space on the dorsal aspect of the foot. The cast was changed every 3–7 days. Typical corrective maneures were performed. Foot displacement into dorsiflexion occured spontaneously as an active motion and also with manipulations. Abduction braces or knee-flexed splints were applied after the complete foot correction. Pirani score and foot dorsiflexion angle were documented during each step of correction.


A Gulati C Walker M Bhatia

Introduction

Venous thromboembolism (VTE) is a significant cause of patient morbidity and mortality, the risk of which increases in orthopaedic patients with lower limb immobilisation. This incidence should in theory reduce if the patients are ambulatory early in the treatment phase. The aim of this study was, therefore, to identify a difference in the incidence of symptomatic VTE by treating acute Achilles tendon rupture patients with conventional non-weight bearing plaster versus functional weight bearing mobilisation.

Methodology

The notes of 91 consecutive patients with acute Achilles tendon rupture were retrospectively reviewed and prospectively followed. The patients' demographics, treatment modality (non-weight bearing plaster versus weight bearing boot), and the type of plaster immobilisation was compared to assess whether they affect the incidence of clinical VTE. The predisposing risk factors were also analysed between the treatment groups.

Out of 91 patients, 50 patients with acute Achilles tendon rupture were treated conservatively in a conventional non-weight bearing immobilisation cast. From these 50 patients, 3 then underwent surgery and were therefore excluded from the results. On the other hand, 41 patients were treated with functional weight bearing mobilisation (Vacupad). Patients who did have a symptomatic thromboembolic event also had an ultrasound scan to confirm a deep vein thrombosis of the lower limb or a CT-scan to confirm pulmonary embolism.


Sara Lima Diogo Robles Moura Martins Daniel Lopes Virginia Amaral João Correia Nuno Ferreira Jorge Alves Carlos Sousa

The purpose of this study was to evaluate the subjective and objective functional outcome after osteosynthesis of the forearm bone fractures with plates and screws (ORIF) or elastic nailing (CRIF).

We evaluated 55 patients (45 men and 10 women) who underwent internal fixation of both forearm bones with CRIF or ORIF, concerning the range of motion of the forearm, wrist and elbow (pronation, supination, flexion and extension), grip strength and a validated outcome measure (DASH score). The mean duration of follow-up was 3 years, and standardized radiographs of the forearm were evaluated. The mean age was 41.6.

We used the Student's t test to compare means and chi-square test to compare proportions.

The mean (confidence interval 95%) of the DASH scale was 29.6 (22.6 to 36.5), significantly higher (p<0.001) than the normative value in the U.S. (10.1). There was a statistically significant reduction of forearm supination (86.4 vs. 64.6, p<0.001) and grip strength (0.63 vs. 0.48, p<0.001) in relation to the opposite member; grip strength decrease correlated with worse subjective outcome (p<0.02). There were no significant differences between groups undergoing ORIF or CRIF. The risk of nonunion and reintervention was not different between groups (p=0214).

Forearm bones fractures are associated with high rates of consolidation and satisfactory mobility of the forearm since we obtain an anatomic reduction of the fracture, as is most easily achieved by plate fixation. However, elastic nailing is a less invasive technique that allows restoring function more quickly with less pain and no increased risk of complications. Given the scant scientific evidence currently available we will require a more comprehensive study to compare the anatomical and functional outcome after ORIF and CRIF.


Sara Lima Rui Martins João Correia Viriginia Amaral Diogo Robles Daniel Lopes Nuno Ferreira Jorge Alves Carlos Sousa

The purpose of this study was to evaluate the results of subcutaneous ulnar nerve transposition in the treatment of Cubital Tunnel Syndrome (CTS) and the influence of prognostic factores such as preoperative McGowan stage, age and duration of symptoms.

36 patients (17 men and 19 women) with CTS who underwent subcutaneous ulnar nerve transposition between 2006 and 2009 were evaluated postoperatively, an average follow-up of 28 months. Sensory and motor recovery was evaluated clinically. The postoperative outcome was based on modified Bishop score, subjective assessment of function and on the degree of patient satisfaction. The dominant side was involved in 61% cases and the mean age was 51.2 years. There were 9 (25%) McGowan stage I, 18 (50%) stage II and 9 stage III patients.

We used the Mann-Whitney and Kruskal-Wallis test to compare continuous variables and chi-square and Fisher Exact Test for categorical variables.

There was a statistically significant improvement of sensory (p=0.02) and motor (p=0.02) deficits. We obtained 21 (58.3%) excellent results, seven (19.4%) fair, six (16.7%) satisfactory, and two bad ones (5.55%). There was a statistically significant improvement of function (p<0.001).

There is controversy in the literature regarding the best surgical treatment for CTS. The duration and severity of symptoms and advanced age, more than the surgical technique, seem to influence prognosis. With the technique used, the satisfaction rate was 86% and 72% recovered their daily activities without limitations. 78% of patients with severe neuropathy improved after surgery. The rates of postoperative complications were comparable with those of other studies. The severity of neuropathy and duration of symptoms (>12months) pre-operatively, but not age, had a negative influence on the outcome.

The results showed that the subcutaneous ulnar nerve transposition is safe and effective for postoperative clinical sensory and motor recovery for several degrees of severity in CTS. Given the major prognostic factors, surgical treatment should be advocated as soon as axonal loss has become clinically evident.


Bernd Grimm Alfons Tonino Ide Heyligers

Introduction

Large wear rate reductions have been shown for crosslinked PE in simulators and short- to mid-term clinical wear studies. However, concerns persist about long-term in-vivo oxidation (especially with annealed PE), late accelerating wear and the possibly higher osteolytic potential of crosslinked PE particle debris. This is the first long-term study comparing conventional to crosslinked PE investigating whether the wear reduction is maintained in the long-term and if reduced osteolysis becomes evident.

Materials & Methods

In a prospective study 48 primary THA patients (Stryker ABG-II, 28mm CoCr heads) were randomized to either receive a first generation crosslinked PE (Stryker Duration: 3MRad gamma irradiation in N2, annealed) or then conventional, now “historic” PE (3MRad gamma irradiation in air). Both groups were statistically non-different (p>0.1) regarding age (63.9 years), gender, BMI, stem and cup size, cup inclination, liner thickness or pre- and post-op HHS leaving the insert material as the only variable.

Patients were followed-up annually using the Harris Hip score, AP and lateral radiographs and digital wear measurements using Roman V1.70 [1, 2]. Wear and radiographic signs of osteolysis were analysed at a mean follow-up of 12.9 years (12.0–13.3). Groups were compared using the t-test (means) or the Fisher Exact test (proportions).


Pilar Aparicio García Oscar Izquierdo Corres Gemma Casellas Garcia Ruiz Castro Ruiz Jose María Cavanilles Walker Lluis Costa Tutusaus Juan Castellanos Alejandro Yunta

Introduction

Distal radius fractures (DRF) are a common injury in the A&E departments, being a major cause of disability of the upper extremity. The aim of this prospective study is to assess the possible association between objective physical variables such as wrist range of movement (ROM), radiological parameters, and upper extremity disability (measured by the DASH questionnaire), after conservative treatment of DRF.

Patients and methods

44 patients with non-operatively managed DRF were enrolled in a prospective cohort study from July 2007 till September 2009.

Inclusion criteria: unilateral DRF in skeletally mature patients, treated non-operatively with closed reduction and cast. Patients who sustained a previous fracture of the wrist, or bilateral wrist fracture, or with dementia, were excluded.

After the closed reduction and inmovilization of the fracture in the A&E department we asked the patients to complete the DASH questionnaire, referring to their baseline pre-fracture state.

All fractures were classified according to the AO classification.

After one year, 36 patients were still available for follow-up purposes. We assesed the following objective physical variables: ROM of both wrists: flexion/extension arc and pronation/supination arch. We recorded the following radiologic parameters: radial angulation, volar angulation and radial shortening. The patient-perceived results were measured by the DASH questionnaire, while pain was measured using the VAS scale.

Statistical analysis was performed using the SPSS 15.0.


Anne Lübbeke Guido Garavaglia Constantinos Roussos Christophe Barea Robin Peter Pierre Hoffmeyer

Introduction

A recent review of the literature on metal-on-metal total hip arthroplasties (THA) revealed the lack of comparative clinical studies with a sufficient sample size and the inclusion of patient-reported outcomes as well as patient activity levels.

Methods

We conducted a prospective cohort study including all metal-on-metal and conventional polyethylene (PE)-ceramic THAs with an uncemented cup (Morscher press-fit cup), a 28mm head and operated upon via a lateral approach at our University hospital between 1/1999 and 12/2008. Only THAs for primary osteoarthritis were included. The study population is part of the Geneva Hip Arthroplasty Registry, a prospective cohort followed since 1996. The following outcomes were compared between the two groups (metal-on-metal=group 1 vs. PE-ceramic bearing=group 2): (1) Complication rates with respect to infection, dislocation and revision, (2) Radiographic outcomes (presence of linear or focal femoral osteolysis, loosening), and (3) Clinical outcomes (Harris Hip score increase, SF-12, activity and patient satisfaction evaluation, presence of groin pain). Patients operated between 1/1999 and 12/2004 were evaluated five years postoperatively by an independent assessor. Cox regression analysis was used to compare incidence rates while adjusting for differences in baseline characteristics.


Aparna Viswanath Jamie Buchanan Lesley Apthorp

Shoulder pain or loss of normal range of motion is a frequent complaint in the outpatient clinic. Of these presentations, rotator cuff injury is a common cause. This can range from mild, transient inflammation of the tendons, to partial tears of tendons, or even full thickness tears. Disruption of the tendons can occur from forceful forward throwing actions undertaken in some sports, for example baseball pitching, more commonly in the UK however, chronic impingement can lead eventually to a tendon tear-usually seen in an older population. Current methods of investigation of such injuries after clinical history and examination, includes plain film radiography, ultrasonography, magnetic resonance imaging and arthrography. We decided to look at how ultrasound can be used in the district general hospital for investigation of such injuries.

Aims

To determine the accuracy of ultrasound as an investigative tool for clinically suspected rotator cuff tears.

Methods

Seventy-five consecutive ultrasonographic study reports, in patients who subsequently underwent arthroscopic examination, were scrutinised and correlated with surgical findings. From this, sensitivity and specificity of ultrasound at this district general hospital were calculated. In addition, this data was compiled for each of the three Consultant Radiologists in order to assess the operator dependent nature of ultrasound.


Sandro Giannini Cesare Faldini Stavroula Pagkrati Matteo Nanni Danilo Leonetti Francesco Acri Maria Teresa Miscione Mohammadreza Chehrassan Valentina Persiani Paola Capra Caludio Galante Marco Bonomo

Objective

Combined metatarso-phalangeal and inter-phalangeal deformity represents about 1% of hallux valgus deformity, and its treatment remains a debated topic, because a single osteotomy does not entirely correct the deformity and double osteotomies are needed. The aim of this study is to review the results of 50 consecutive combined metatarso-phalangeal and inter-phalangeal hallux valgus treated by Akin proximal phalangeal osteotomy and SERI minimally invasive distal metatarsal osteotomy.

Material and Methods

Fifty feet in 27 patients, aged between 18 and 75 years (mean 42 years) affected by symptomatic hallux valgus without arthritis were included. Two 1-cm medial incisions were performed at the metatarsal neck and at proximal phalanx. Then SERI osteotomy was performed to correct metatarso-phalangeal deformity and Akin osteotomy was performed to correct interphalangeal deformity. Both osteotomies were fixed with a single K-wire. A gauze bandage of the forefoot was applied and immediate weight-bearing on hindfoot was allowed. K-wire was removed after 4 weeks. All patients were checked at a mean 4 year follow-up.


Ian Starks Andrew Frost Peter Wall Justin Lim

The management of pelvic fractures remains a challenging problem for orthopaedic surgeons. The prompt recognition of unstable fracture patterns is important in reducing mortality and morbidity. It is perceived wisdom that a fracture of the transverse process of L5 is a predictor of pelvic fracture instability. There is a paucity of evidence in the literature to support this belief. The aim of our study was to determine if a fracture of the transverse process of L5 was a predictor of pelvic fracture instability.

The Hospital Trauma database was reviewed. Between 2006 and 2009, 65 pelvic fractures were identified. They were classified according to the Burgess and Young classification. There were 37 stable and 28 unstable fractures. 14 patients had an associated fracture of the transverse process of L5; 9 were associated with an unstable fracture pattern. The odds ratio was 3; the relative risk 1.7.

A fracture of the transverse process of L5 is associated with an increased risk of pelvic fracture instability. Its presence should alert the attending physicians to the possibility of an unstable injury.


Sandro Giannini Cesare Faldini Stavroula Pagkrati Danilo Leonetti Matteo Nanni Francesco Acri Maria Teresa Miscione Mohammadreza Chehrassan Valentina Persiani Paola Capra Caludio Galante Marco Bonomo

Objective

High grade hallux rigidus is a forefoot deformity characterized by a limitation of dorsiflexion of the first toe associated with pain, and severe damage of the first metatarsophalangeal joint. Most authors recommended resection arthroplasty or arthrodesis of the first metatarsophalangeal joint. The aim of this study was to present the results of our series of 42 consecutive cases of severe hallux rigidus treated by resection of the first metatarsal head and implant of a poly D-L lactic (PDLLA) bioreabsorbable spacer to promote the interposition of fibrous tissue to preserve the range of motion of the joint.

Material and methods

Forty-two feet in 27 patients affected by high grade hallux rigidus were included in the study. Surgical treatment consisted of resection of the first metatarsal head and positioning of a poly D-L lactic acid (PDLLA) bioreabsorbable implant. Post-operative care consisted in gauze bandage of the forefoot, and immediate weight-bearing with talus shoes for 3 weeks. All patients were clinically and radiographically evaluated preoperatively and checked at a mean 6 (5–7) year follow-up.


Antoine Serre Daniel Lepage Gregoire Leclerc Laurent Obert Patrick Garbuio

The treatment for trochanteric femoral fractures is still challenging. Since 2005, we are using 2 new implants: Gamma3™ nail and the PFN-A™.

All patients with a fracture of the trochanteric area were included in an observational study during 3 years.

Objectives were radiographics and clinics (complications) comparaison of these 2 new devices.

We included 426 patients (236 Gamma3™ nails, 190 PFN-A™). We faced the epidemiological data, per and post-operative complications. The tip-apex distance and the position of the cephalic implant were studied.

The 2 implants were well positionned in more than 80%, with no statistic diffferencie. We found a a cut-out rate of 1,4 % and a re-operation rate of 4,9 %. These rates of usual complications are very low in comparaison with litterature. We did not found a statistic difference between these 2 differents nails.

But, we observed 2 unusual complications: for the Gamma3™ nail, a high rate of automatic distal locking failure, and for the PFN-A™, many patients complained of thigh pain resulting from a prominent cephalic blade. These 2 new complications can be avoided by small changes in the operative procedure.

In our mind these 2 implants can be used for treating all patients with trochanteric fracture, but we need other studies to compare these nails with the new generation of sliding plate


Victor Rodriguez Vega David Cecilia Laura Suarez Alberto Jorge Ismael Auñon Marta Rojo David Blanco Vicente Guimera Beatriz Bravo Lorena Garcia Carlos Resines

Introduction

Distal radius fractures are one of the most common injuries attended in hospitals. Throughout the years the treatment has change from simple cast to ORIF.

Objectives

To compare the functional and radiographic results in the treatment of the distal intrarticular radial fractures treated by volar buttress plate (T plate AO® Synthes, Oberdorf, Suiza) and fixed volar angle locking plate (DVR® Depuy, Warsaw, Indiana, USA).


Ulf Schlegel J Siewe K Püschel A Gebert De Uhlenbrock P Eysel M Morlock

Despite proven advantages, pulsatile lavage seems to be used infrequently during preparation in cemented total knee arthroplasty. This remains irritating, as the technique has been suggested to improve radiological survival in cemented TKA, where aseptic loosening of the tibial component represents the main reason for revision. Furthermore, there may be a potential improvement of fixation strength for the tibial tray achieved by increased cement penetration. In this study, the influence of pulsed lavage on mechanical stability of the tibial component and bone cement penetration was analyzed in a cadaveric setting. Six pairs of cadaveric, proximal tibia specimen underwent computed tomography (CT) for assessment of bone mineral density (BMD) and exclusion of osseous lesions. Following surgical preparation, in one side of a pair, the tibial surface was irrigated using 1800ml normal saline and pulsatile lavage, while in the other side syringe lavage using the identical amount of fluid was applied. After careful drying, bone cement was hand-pressurized on the bone surface, tibial components were inserted and impacted in an identical way. After curing of cement, specimen underwent a postimplantation CT analysis). Cement distrubution was then assessed using a three-dimenionsional visualization software. Trabecular bone, cement and implant were segmented based on an automatic thresholding algorithm, which had been validated in a previous study. This allowed to determine median cement penetration for the entire cemented area. Furthermore, fixation strength of the tibial trays was determined by a vertical pull-out test using a servohydraulic material testing machine. Testing was performed under displacement control at a rate of 0,5mm/sec until implant failure. Data was described by median and range. Results were compared by a Wilcoxon matched pairs signed rank test with a type 1 error probability of 5 %. Median pull-out forces in the pulsed lavage group were 1275N (range 864–1391) and 568N (range 243–683) in the syringe lavage group (p=0.031). Cement penetration was likewise increased (p=0.031) in the pulsed lavage group (1.32mm; range 0.86–1.94), when compared to the syringe irrigated group (0.79mm; range 0.51–1.66). Failure occurred in the pulsatile lavage group at the implant-cement interface and in the syringe lavage group at the bone-cement interface, which indicates the weakness of the latter. Altogether, improved mechanical stability of the tibial implant and likewise increased bone cement interdigitation could be demonstrated in the current study, when pulsed lavage is implemented. Enhanced fixation strength was suggested being a key to improved survival of the implant. If this is the case, pulsatile lavage should be considered being a mandatory preparation step when cementing tibial components in TKA.


Lars Dahlin Chris Bainbridge Piotr Szczypa Joseph Cappelleri Yiannis Kyriazis Robert Gerber

Introduction

Dupuytren's disease (DD) is a fibro-proliferative disorder of the palmar fascia whereby a collagen cord contracts affected joints, resulting in flexion deformity that can impair hand function. Currently, surgery is the only effective treatment option in Europe. This 2-part study, consisting of a surgeon survey and chart audit, was designed to assess current surgical practice patterns by DD severity. We report results from the surgeon survey.

Methods

A total of 687 participants, including 579 orthopedic surgeons (of which 383 were hand specialists) and 108 plastic surgeons, who had been practicing for >3 and <30 years and operated on 5 DD patients between September and December 2008 were surveyed in 12 countries (UK, Germany, France, Italy, Spain, Hungary, Czech Republic, Poland, Netherlands, Sweden, Denmark, Finland). The survey included queries about procedures performed, factors involved in the decision to use a procedure, satisfaction with the procedure, use of physiotherapy, and recurrence.


Chris Bainbridge Anthony Houston Graeme Jones Richard Milner Stephan Wilbrand

Introduction

In Europe, injectable collagenase clostridium histolyticum (CCH) is a novel, minimally invasive, non-surgical therapy with efficacy in correcting Dupuytren's contracture (DC). We evaluated the efficacy and tolerability of 5 CCH injections using a protocol designed to follow clinical practice.

Methods

This was a 20-center, 9-month, open-label study in which DC patients with primary flexion deformities 20° (100° for MP; 80° for PIP) received 3 CCH (0.58 mg) injections/joint (5 injections/patient) at 30-day intervals. The primary endpoint was clinical success, defined as a reduction in contracture to 5° 30 days after the last injection (“Day 30”). After first injection into a prioritized joint, patients opted to receive up to 2 more injections into the same cord or cords from other affected joints whether or not they achieved clinical success with the first joint. Adverse events (AEs) were monitored.


Saravana Karuppiah Rebecca Halas Timothy Dougall

Background

Distal radial fractures in the elderly population have been traditionally managed by closed techniques, primarily due to their poor bone quality and low functional demands. Since the introduction of the volar locking plate (VLP), which provides a good fixation in osteoporotic bones, there maybe an increased use of open reduction and internal fixation (ORIF) in the elderly population.

Aim

We aimed to determine the changes in the management of these fractures in Scotland, and whether this differs between specialist regional centres and district general centres.


Daniel Köhler Tim Pohlemann Ulf Culemann

Background

The suicidal jumper's fracture of the pelvis is a special form of sacrum fractures associated with high energy trauma. The typical H-type fracture pattern runs transforaminal on both sides with a connecting transverse component between S1 and S3. Due to the high-grade instability operative treatment is imperative. Aim of this study was to compare iliosacral double screwing (2×7,3mm canulated screw with 16mm thread) with spinopelvic internal fixation.

Methods

Both methods were tested on 6 synthetic and 6 anatomical pelvises. After osteotomy and alternating osteosynthesis stability was tested with a universal testing machine (Zwick) in a simulated two-leg stand. Data were generated by a 3-dimensional computer-assisted ultrasoundsystem (Zebris©) (3 translational datasets x,y,z and 3 ankles). Testing was performed after preload of 50N and two setting cycles of 100N followed by a full load cycle of 150N. ASCII-data were then transferred to SPSS for statistical analysis.


Stefano Zaffagnini Giulio Maria Marcheggiani Muccioli Tommaso Bonanzinga Cecilia Signorelli Nicola Lopomo Simone Bignozzi Danilo Bruni Marco Nitri Alice Bondi Maurilio Marcacci

INTRODUCTION

This study aimed to intra-operatively quantify the improvements in knee stability given both by anatomic double-bundle (ADB) and single-bundle with additional lateral plasty (SBLP) ACL reconstruction using a navigation system.

MATERIALS AND METHODS

We prospectively included 35 consecutive patients, with an isolated anterior cruciate ligament injury, that underwent both ADB and SBLP ACL reconstruction (15 ADB, 20 SBLP). The testing protocol included anterior/posterior displacement at 30° and 90° of flexion (AP30–AP90), internal/external rotation at 30° and 90° of flexion (IE 30–IE90) and varus/valgus test at 0° and 30° of flexion (VV0–VV30); pivot-shift (PS) test was used to determine dynamic laxity. The tests were manually performed before and after the ACL reconstruction and the data were acquired by means a surgical navigation system (BLU-IGS, Orthokey, USA). Comparisons of pre- and post-reconstruction laxities were made using paired Student t-test (P=0.05) within the same group; comparison between ADB and SBLP groups was indeed performed using independent Student t-test (P=0.05), analysing both starting pre-operative condition and post-operative one.


Josep Cortina Gualdo David Barastegui Fernandez Jordi Teixidor Serra Jordi Tomàs Hernández Vicente Molero Garcia Alejandro Fernández Bautista Ramon Monforte Alemany Joan Nardi Vilardaga Enric Cáceres Palou

Introduction and objectives

High-energy pelvic fractures are life-threatening injuries. Approximately 15% to 30% of patients with high-energy pelvic injuries are hemodynamic unstable, hemorrhagic shock remains the main cause of death in patients with pelvic fractures, with an overall mortality rate from 6% to 35%. The correlation between fracture pattern and mortality in polytrauma with pelvic fracture has been previously investigated. However, the purpose of our investigation was to evaluate the relationship of hemodynamic instability with the pelvic fracture pattern according to different classifications.

Materials and Methods

A retrospective study of high-energy pelvic fractures was performed for consecutive patients admitted to the emergency Level I trauma center in the polytrauma unit of our institution from June 2007 to June 2010. A total of 759 patients polytrauma were attended, whom 100 had a pelvic fracture and were included in our study. Demographic data, mechanism of injury and associated injuries were recorded. The patients were classified as hemodynamic stable or unstable according to the ATLS protocol. The pelvic fracture patterns were divided into stable and unstable according to Young-Burgess and Tile classifications. Statistical analysis was performed to determine the relationship between fracture pattern and hemodynamic stability. Secondary outcomes were obtained: the relationship with TCE and pulmonary injury, usefulness of the external fixation, relationship between fracture pattern and embolization requests. Chi-square test was used for the analysis and OR test.


Richard Sellei Phillip Kobbe Matthias Knobe Phillip Lichte Roman Pfeifer Martin Schmidt James Turner John Grice Hans Pape

Objectives

The additive use of an external modular device may improve dorsal compression forces in pelvic external fixation. This would improve the efficiency of indirect reduction and stabilization with an anterior pelvic external fixator. The purpose of this study was to determine the forces of the posterior pelvis achieved by a new device improving the application of a supraacetabular anterior external fixator compared with other constructs.

Material and Method

Synthetic pelvic models were used. Complete pelvic ring instability was created by symphyseal and unilateral sacroiliac joint disruption. Four different constructs of fixation were tested. A pressure-sensitive film was placed in the sacroiliac joint. The constructs were applied in a standardized way. The maximum sacroiliacal compression loads (N) of each trial was recorded. Statistics was performed with the student t-test.


Fritzell Peter Acke Ohlin Fredrik Borgström

Background

Balloon kyphoplasty (BKP) is a minimally invasive cementing procedure, occasionally used in patients with painful vertebral compression fractures (VCF). In this multicenter Swedish RCT, we evaluated the cost-effectiveness of BKP compared with standard medical treatment, Control, in osteoporotic patients with acute/sub-acute VCF (<3 months). In a multicenter European clinical study (FREE trial) including 300 patients and FU after one year, BKP was suggested to be a safe and effective procedure in selected patients. The current study includes the Swedish patients in the FREE trial Method: Hospitalized patients with a back pain level of at least 4/10 on a visual analogue scale due to of VCF between Th5–L5 (confirmed by MRI) were randomized to either BKP or Control treatment (standard medical treatment with pain medication and functional support). All VCF-associated costs (hospital, primary care, rehabilitation, community care, private care, pharmaceuticals, assistance by relatives, work absenteeism) were identified and reported from the perspectives of cost to society, and costs to the healthcare system. Primary outcome was quality of life change (QoL) measured with the preference based EQ-5D instrument. The accumulated quality adjusted life years gained (QALYs) and costs per QALY gained was assessed. Willingness to pay (WTP) for a QALY gained in Sweden was estimated at approximately SEK 600,000 (EURO 62,500). Sensitivity analyses were performed.

Results

Between February 2003 and December 2005, 70 patients were randomized to BKP (n=35) or to standard medical treatment (n=35). Three patients in the Control group declined to participate in an economic evaluation, and only patients answering EQ-5D at all FU occasions (1-3-6-12-24 months) were included in the analyses, leaving in all 63 patients, BKP=32, Control=31. Baseline data were similar. The mean age in the BKP group was 72 years (71% women) vs. 75 years (78% women) in the Control group. Baseline difference in QoL was adjusted for using statistical methods. There were no cross overs. Four patients in the BKP group and three patients in the Control group died within two years of causes not related to the VCF. Costs were collected using “cost diaries” in mailed questionnaires after 1-3-6-12-18-24 months. Costs and EQ-5D values (0 at FU after death) were carried forward. Total mean societal cost per patient for BKP and Control was SEK 160,017 (SD 151,083) and SEK 84,816 (SD 40,954), respectively. The difference was significant 75,198 (95% CI 16,037 to 120,104). The accumulated mean difference in QALYs was 0.085 (−0.132 to 0.306) units in favour of BKP. Cost per QALY gained using BKP was SEK 884,682 (EURO 92,154) with high uncertainty assessed using the bootstrapping technique, and demonstrated on the cost-effectiveness plane and on the acceptability curve. When the EQ-5D values from all patients in the FREE trials were included in a sensitivity analysis, cost/QALY was SEK 359,146 (EURO 37,411) Conclusion: Costs were significantly higher for BKP compared with standard medical treatment, with no significant difference in QALYs gained. In this selected patient population with vertebral compression fracture due to osteoporosis, BKP could not be concluded as cost-effective after two years


Saravana Karuppiah Tom Walshaw Saravana Karuppiah Ian Stewart

Introduction

Anterior Cruciate ligament reconstruction is a common operation in orthopaedics surgery. A common complication of whilst havesting the hamstring tendon is injury to the infra-patellar branch of the saphenous nerve (IPBSN), resulting in altered sensation to the anterior and lateral aspects of the knee and leg.

Aim

The aim of this study was to further understand the course of this nerve in relation to surgical approach to anterior cruciate ligament reconstruction.


Dominik Meyer Jess Snedeker Peter Koch Robert Weinert-Aplin Mazda Farshad

Introduction

ACL reconstruction using hamstring tendons has gained general acceptance. However, it has been recommended to seek a tight fit of the tendon in the bone canal in order to provide circumferential contact and healing of the graft, and to prevent secondary tunnel widening. Recent findings show, that the graft dynamically adapts to pressure in the canal resulting in a potentially loose graft-bone contact. It was the goal of this study to understand the viscoelastic behaviour of hamstring grafts under pressure and to develop a new method for tendon pre-conditioning to reduce the graft volume before implantation, in order to reduce the necessary bone canal diameter to accommodate the same graft.

Material and Methods

Flexor digitorum tendons of calf and extensor digitorum tendons of adult sheep were identified to be suitable as ACL grafts substitutes for human hamstring tendons in vitro. The effect of different compression forces on dimensions and weight of the grafts were determined. Further, different strain rates (1mm/min vs 10mm/min), compression methods (steady compression vs. creep) and different compression durations(1, 5, 10min) were tested to identify the most effective combination to reduce graft size by preserving its macroscopic structure.


Paul Robinson Tim Harrison Andrew Cook Martyn Parker

Introduction

There has been little research into the effect of suffering a simultaneous hip and upper limb fragility fracture. The aim of this study is to describe the characteristics of this important group of patients and to define the effect on outcomes such as mortality and length of stay.

Materials and methods

Hip fracture data in our unit is collected prospectively and entered into a database. All study data was taken from this database. Patients under 60 years of age were excluded from the study.


José Fraga Ferreira Rui Cerqueira Sofia Viçoso Tiago Barbosa João Oliveira Tiago Basto João Lourenço

It appears that double bundle anterior cruciate ligament reconstruction can reproduce the original anatomy of the ligament, restoring normal kinematics and rotational control of the tibia. But an anatomical single bundle reconstruction may present very similar results, with minor technical difficulties and lower costs.

We compared two groups of 25 patients each, that underwent ACL reconstruction by the same surgeon, with a follow-up of 12–36 months. One group had double bundle reconstruction with hamstring and the other had single bundle anatomical reconstruction with patellar tendon.

Patients underwent a subjective evaluation and clinical testing with instrumented laxity with Rolimeter, and the data entered in the IKDC 2000 scale Double tunnel hamstring Vs bone-tendon-bone: Functional outcome of 85.6% Global Class A and B vs. 82.1% Class A and B. The subjective outcome (IKDC 2000) was 90.93 vs. 91.47. Pivot-shift test with 87% patients in class A and class B at 9.7% Vs 75% patients in class A, 21.4% for class B. The Rolimeter gave an average Lachman value of 2,56 and anterior drawer test of 2,88 Vs average Lachman value of 3.59 and anterior drawer test of 2.92. One leg hop test showed 85.7% knees class A, 9.5% knees class B vs. 90.4% knees class A and, 2.8% knees class B.

The subjective score was slightly higher in the single bundle anatomical reconstruction with patellar tendon, despite the overall functional outcome being higher in the double tunnel technique with hamstrings. The average Lachmann in the patellar tendon group was 1 mm higher. The rotational stability in the double tunnel was higher.

The same surgeon had better results in the double tunnel hamstrings technique, despite less experienced with this technique, which is more demanding, probably reflecting objective advantages over the single bundle reconstruction with patellar tendon


Chris Peach Richard Wain Michael Woodruff

Aim

To evaluate the correlation between the clinical Kirk Watson test and arthroscopic Geissler classification in scapholunate instability.

Methods

All patients undergoing wrist arthroscopy between April 2006 and April 2010 were evaluated. Patients were included in the study if they had a Kirk Watson test and a wrist arthroscopy with an assessment of the stability of the scapholunate joint using the Geissler classification. Patients who had a Kirk Watson test performed with subsequent normal scapholunate joint at arthroscopy were included as a control group. Geissler grades 1 and 2 and grades 3 and 4 were grouped for further analysis into low and high grade instability groups respectively.


José Fraga Ferreira Rui Cerqueira Sofia Viçoso Tiago Barbosa João Oliveira João Lourenço

The median nerve compression in the carpal tunnel is the most common compression syndrome of the upper limb. In most cases it is idiopathic but may also occur from anatomical, traumatic, endocrine, rheumatic or tumoral causes.

Chow's endoscopic technique was initially used to treat this disease and then modified to a mini-open approach through a single palmar incision. This incision is similar to the one used in endoscopic release by Agee. After exposing the proximal part of the transverse carpal ligament a meniscus knife is advanced until there is a complete section of the ligament, without endoscopic equipment.

Between 2004 and 2006, 200 hands in 179 patients with a diagnosis based on clinical and electromyographic criteria were operated by this mini-open technique. The mean follow-up was 49 months (minimum of 34 months and a maximum of 70 months).

50 randomly selected patients were submitted to the self-administered Boston questionnaire. 50 patients treated by the minimal-incision decompression during the same period were also given the questionnaire. The aesthetic satisfaction was registered as well as if they would have surgery on the other hand or would recommend the procedure.

This mini-open technique is another technique available to the surgeon that allows very similar functional results to endoscopic surgery, without use of specific material and with a shorter surgical time.


Thompson Opara Marcos Katchburian

Introduction

Carpal tunnel syndrome is the commonest peripheral nerve compression neuropathy. Carpal tunnel release (CTR) is a very successful operation. Failed CTR mainly presents as persistence of symptoms, recurrence and new symptoms. The commonest presentation is persistence of symptoms suggested to be due to inadequate release of transverse carpal ligament (TCL) [3], and ante brachial fascia (ABF) [2].

Aim

We were looking at the rate of recurrence after CTR and the levels of skills of the primary surgeon.


Christoph Josten Jan-Sven Jarvers Hans-Joachim Riesner Alexander Franck Stefan Glasmacher Christian Schmidt

Purpose

In stabilisations of atlantoaxial instabilities it holds risks to injure the A. vertebralis as well as neurological structures. Furthermore the posterior approach of the upper part of the cervical spine requires a huge and traumatic preparation of the soft tissue. However the anterior transarticular C1-2 fusion (ATF) is less traumatic and offers almost the same strengh of the stabilisation.

Methods

Since the 01/2007 22 multimorbid patients with atlanto-axial instabilities of different entities were treated via the ATF, were regular examined radiologicaly (x-ray/CT) and the procedure critically judged.


Mohammed Bhutta Charlotte Cross

BACKGROUND

From 1995 the cost of litigation to the National Health Service (NHS) from surgical procedures has been over 1.3 billion GBP. Spinal patients can present diagnostic challenges and the consequences of delayed diagnosis and surgical complications can be devastating. As a consequence these patients represent a high risk when surgeons seek to indemnify themselves.

We therefore, aim to highlight the litigation patterns for these injuries within the United Kingdom.

METHOD

Data was obtained from the NHS Litigation Authority from 2002 to 2010 which was analysed.


Raquel Sanchis Amat Daniel Crespo Gonzalez Carlos Juando Amores Francisco Espi Esciva Jaume Balaguer Andres

INTRODUCTION

Percutaneous surgery is an increasingly accepted technic for the treatment of Hallux valgus but it has some limitations when the intermetatarsal angle ismoderate to severe, having high risk of recurrence.

The mini tight-rope used as a complement for precutaneous surgery avoids complications of open surgery osteotomies (delays consolidation, pain, screws protusion, infection) and it allows us continue with the recurrent trend towards minimal invasive surgery.

MATERIAL AND METHOD

Between 2007 and 2009, 60 patients with severe Hallux valgus were treated in our Hospital using the percutaneous mini tight-rope. The mean age of patients was 62, 5 patients were man and 55 were woman. The mean follow-up was 18 months.


Paul Cowling Ian Richards Clarke Clarke Nick Cooke

Patients most at risk of osteoporosis are post-menopausal women. However, for many such women, presentation of osteoporosis is only made following their first fragility fracture. Often in the UK, osteoporosis investigation occurs following discharge, and any subsequent secondary prevention starts in the community. This may result in patients with osteoporosis not being investigated or not receiving correct prophylactic treatment.

143 post-menopausal women (av. age 77.7 years) starting secondary osteoporosis prophylaxis following fragility fractures requiring operative intervention were included in this retrospective study. Osteoporosis was defined by DEXA scan using the WHO criteria (122 hip fractures and 21 wrist fractures), following the UK's national guidelines for osteoporosis prophylaxis. Treatment was started following discussion and explanation of treatment with each patient, and either commenced by the surgical team during the acute hospital admission with the fracture, or in an out-patient setting within 6 weeks of the fracture by an orthopaedic specialist nurse. To check compliance, either the patient themselves or the patients' family physician was contacted.

Results showed that 120 of the women (83.9%, 102 hip fractures, and 18 wrist fractures) were still compliant with secondary osteoporosis prophylaxis at an average follow-up of 200 days (5 hip fractures lost to follow-up, 0 wrist fractures). 12 women with hip fractures died (0 wrist fractures), and 6 women stopped taking their prophylaxis (3 hip fractures, 3 wrist fractures): 4 for medical reasons, and 2 for unknown reasons. No women sustained further fractures.

Few studies have previously investigated compliance of osteoporosis secondary prevention, and our results compare favorably. We therefore recommend the prompt commencement of secondary prevention treatment by the orthopaedic surgical team following osteoporotic fractures.


Karthik Karuppaiah Rajesh Nanda John Stothard

Aims

The objective of our study is to identify the causes for recurrence and to evaluate the results of our technique.

Material and Methods

We retrospectively analysed 18 patients (12 females; 6 males) who had both clinical and electrophysiological confirmation (7 focal entrapments; 11 severe entrapments) of recurrent carpal tunnel syndrome. In all the patients, after releasing the nerve a vascularised fat pad flap was mobilised from hypothenar region and sutured to the lateral cut end of flexor retinaculum. All the patients were assessed post-operatively for relief of pain, recovery of sensory and motor dysfunction.


Karthik Karuppaiah Sanjay Miranda

Introduction

Surgical treatment is justified in patients with fifth metacarpal shaft fractures with angulation exceeding 30 degrees, as these patients are prone to have shortening, restriction of movements, decreased efficiency of the flexor tendons and poor cosmetic results1,2. The authors describe a new technique where these patients can be treated in the clinic non-surgically.

Material and Methods

Twenty-three patients with angulated fractures were prospectively enrolled for the study from Jan 2009 to Dec 2009. After appropriately instructing the patient, an ulnar nerve block was performed at the wrist. Once the nerve block had taken effect, the fracture was manipulated and an ulna gutter 3-point moulded splint was applied in the plaster room. The reduction was then confirmed with an x-ray. The patients were seen at 3 weeks for splint removal and for long-term follow-up at least 6 months later.


Patrick Hahn Martin Komp Harry Merk Georgios Godolias Sebastian Ruetten

Objectives

Juxtafacet cysts of the spine can cause radicular pain, neurological symptoms and are often associated with spinal degeneration. The mainstay of treatment of juxtafacet cysts is surgical resection with laminotomy and resection of the cyst. Other methods, including epidural steroid and facet injections are mostly temporarily effective. The aim of this study is the sufficient decompression with reduced traumatization and destabilization with the full-endoscopic interlaminar and transforaminal technique.

Methods

60 patients with unilateral, single-level juxtafacet cysts were included in this study. 30 Patients (group 1) were operated in full-endoscopic technique (22 interlaminar, 8 trans-/extraforaminal) and 30 Patients (group 2) with conventional microscopic-assisted technique. The full-endoscopic operation was performed with 6.9-mm endoscopes with 4.1-mm intra-endoscopic working canal. The follow-up was 18 months. 27 (91%) patients were followed. Additionally to general parameters validated scores were used.


Michael Zlowodzki Coen Wijdicks Bryan Armitage Peter Cole

Introduction

Femoral neck fractures are a large clinical and economical problem. One of the most common fixation options for femoral neck fractures are multiple cancellous screws. A previous clinical study has shown the lack of washers to be the single largest predictor of fixation failure in the treatment of femoral neck fractures with cancellous screws. This finding was somewhat surprising as washers do not prevent the screws from backing out and do not provide any increase resistance to varus collapse. Therefore a follow-up biomechanical study was designed to test this observation. The purpose was to evaluate the maximal insertional torque of screws in osteoporotic bone with and without washers. We hypothesized that the lateral cortex of an osteoporotic proximal femur does not provide sufficient counter resistance for the screw heads to obtain maximum torque upon screw insertion in the femoral head and that the use of washers would increase screw purchase by providing a larger rigid surface area and subsequent higher counter resistance thereby allowing a higher maximal screw insertion torque.

Methods

We used eight matched pairs of osteoporotic fresh-frozen human cadaveric femurs (age >70 years, all female). Two screws each were inserted in each femur either with or without a washer and maximal insertional torque was measured using a 50 Nm torque transducer. The testing was performed using a customized device which allowed the torque transducer to apply a constant axial force and torque speed to the screws. A paired Student's t-test was used to compare the maximal screw insertional torque of screws with washers versus screws without washers in matched pairs.


Bernd Stoeckl

Introduction

Total femur implantation is a rare and challenging procedure in final revision surgery of hip and knee arthroplasties. Reports of this operation technique are even rare in literature. In this study we retrospectively analyse our patients with total femur implants.

Material and Methods

Between October 2002 and February 2009 we implanted 27 total femurs in hip and knee revision surgery cases. We used the modular prosthesis system–Megasystem C® by Waldemar Link–in all cases. Our 22 female and 5 male patients had a mean age of 76 years (range 45–88). Indications for the procedure were loosening of megaprosthesis of the hip in 12 cases; 2 with massive distal migration, 1 with penetration into the knee joint and 1 after two step revision procedure. In 13 cases a periprosthetic indicated a total femur implanatation due to massive bone loss; 1 breakage of a long femoral stem, 5 fracture of osteosynthesis materials, 3 after prosthesis revisions and 1 pseudoarhrosis of femur and tibia after knee arthroplasty. We analysed perioperative complications, clinical status and result and further revision within follow up time.


Jaime Jorge Sánchez Ruas Jesús Burgos Flores Fernando Aranda Romero Teresa Del Olmo Hernández Gema De Blas Carlos Barrios Eduardo Hevia Ignacio Regidor Carlos Correa Gorospe Miguel Ruíz Ibán Jorge Díaz Heredia José López Mondéjar Luis Berrendero

Introduction

A new triggered electromyography test for detection of stimulus diffusion to intercostal muscles of the contralateral side during thoracic pedicle screw placement was evaluated. Experimental research was carried out in order to determine if, using this test, neural contact at different aspects of the spinal cord and nerve roots could be discriminated.

Methods

Nine industrial pigs (60–75 kg) had 108 pedicle screws placed bilaterally in the thoracic spine (T8–T13). Neural structures were stimulated under direct vision at different anatomic locations from T9 to T12. Recording electrodes were placed over the right and left intercostal muscles. Increasing intensity of the stimulus was applied until muscle response was detected at the contralateral side (diffusion phenomenon). After this first experiment, the thoracic spine was instrumented. Screws were placed in the pedicle in two different positions, the anatomic intrapedicular location and with purposeful contact with the neural elements.


Kiran Singisetti Shyam Swarna I Hugh

INTRODUCTION

Scapholunate instability is a common form of carpal instability and Brunelli procedure has been advocated as a surgical intervention for this difficult problem.

MATERIALS AND METHODS

Twenty five patients with clinical and radiological diagnosis of scapholunate dissociation were included in the study. Mean age of the patients was 37 years. All the patients were treated by modified Brunelli procedure, with the flexor carpi radialis tendon being passed through a drill hole in scaphoid and sutured to radiotriquetral ligament. All patients had a wrist arthroscopy prior to the index procedure and associated injuries recorded. The average postoperative follow up for the patients was 60 months.


Jaime Jorge Sánchez Ruas Jesús Burgos Flores Fernando Aranda Romero Teresa Del Olmo Hernández Gabriel Piza Vallespir Gema De Blas Elena Montes Alberto Caballero García Andrés Barriga Martín J Collazo Eduardo Hevia Carlos Correa Gorospe Carlos Barrios

Objectives

To determine the limits of spinal displacement before the onset of neurophysiological changes during spinal surgery. Assessing if the type of force applied or the section of the adjacent nerve roots increases the tolerance to displacement.

Methods

Experimental study in 21 domestic pigs. Three groups were established according to the displacing force applied to the cord: separation (group 1, n=7), root stump pull (group2, n=7) and torque (group3, n=7). Successive records of cord-to-cord motor evoked potential were obtained. The displacing force was removed immediately when neurophysiological changes observed. The experiment was repeated after sectioning the adjacent nerve roots.


Carlos Lozano Alvarez Manolo Ramírez Valencia Antonia Matamalas Adrover Antoni Molina Ros Ana Clara Garcia De Frutos Guillem Saló Bru Andreu Lladó Blanch Enric Cáceres IPalou

Introduction

Chronic pain is one of the adverse outcomes in surgery for degenerative lumbar pathology (DLP). Postoperative complications as DVT, and chronic pain in pathologies as thoracotomy or breast cancer have been associated with poor control of postoperative pain.

Study design

Prospective study of patients undergoing surgery for DLP.


Carlos Lozano Alvarez Manolo Ramírez Valencia Antonia Matamalas Adrover Antoni Molina Ros Ana Clara Garcia De Frutos Guillem Saló Bru Andreu Lladó Blanch Enric Cáceres IPalou

Introduction

An important number of factors affecting the outcome of surgical treatment have been identified, and these factors can affect the patient's selection for lumbar surgery.

Study Design

Retrospective study with data collected prospectively on patients undergoing surgery for degenerative lumbar pathology (DLP).


Guillaume Odri Nicolas Fraquet Julien Isnard Hervé Redon Renaud Frioux François Gouin

Cam type femoroacetabular impingement (FAI) is due to an aspheric femoral head, which is best quantified by the alpha angle described on MRI and CT-scan. Radiographic measurement of the alpha angle is not well codified and studies from the literature cannot conclude on the best view to measure it. Most authors also describe a mixed type FAI which associates an aspheric femoral head with an excessive anterior acetabular coverage of the femoral head. Anterior center edge (ACE) angle has been described on the false profile view to measure anterior acetabular coverage in hip dysplasia and has never been evaluated in FAI. In this study, we developed a new lateral hip view which associates a lateral view of the femoral neck and a false profile view of the acétabulum, which we called profile view in impingement position (PVIP).

Twenty six patients operated for FAI had CT-scan, the PVIP and the false profile view of one or two hips according to pain. A control group of 19 patients who did not suffer from the hip had the PVIP. Alpha angles were measured twice on 17 CT scan of FAI patients by two observers and compared with the alpha angles measured on the corresponding hip PVIP by a correlation analysis. Alpha angles were measured twice on 45 PVIP in FAI patient and on 19 PVIP in the control group by three observers. ACE angles were measured once on 15 PVIP and on 15 false profile views. Means were compared by two tail paired t-tests, intra- and inter-observer reliability were measured by intraclass correlation coefficient.

Mean alpha angle on CT scan was 65.8° and 65.6° for observers 1 and 2 respectively (p>0.05). It was 63.6° and 64.3° on the PVIP (p>0.05). No significant difference was found between CT scan and radiographic measurements, and Pearson's correlation coefficients were good at 0.74 and 0.8. ICC was 0.86 for inter-rater reliability, and 0.91 for intra-rater reliability for CT-scan alpha angle measures. ICC for PVIP measures varied from 0.82 to 0.9 for intra-rater reliability and from 0.6 to 0.9 for inter-rater reliability. Mean alpha angle measured on PVIP in FAI patients was 63.3° and was 44.9° in control subjects and the difference was significant (p<0.001) for the three observers. None of the FAI patients and 88% of the control subjects had an alpha angle < 50°. Mean ACE angle was 26.8° on PVIP and 32.8° on the false profile view, the difference was significant (p=0.015), and the Pearson's correlation coefficient was moderate (r=0.58).

The PVIP is a reliable radiographic view to measure the alpha angle. It allows a good quantification of the alpha angle comparable to CT-scan measurements and permits to differentiate patients from control subjects. PVIP is not a good view to quantify anterior edge angle probably because of acetabular retroversion due to the hip flexion needed in this view. Mean ACE angle measured on the false profile view in FAI patient was comparable to ACE angle in general population reported in the literature.


Jean-Charles Aurégan Maxime Bérot Hélène Magoariec Thierry Hoc Thierry Bégué Didier Hannouche Frédéric Zadegan Hervé Petite Morad Bensidhoum

Introduction

Osteoporosis is a metabolic disease of the bone responsible for a loss of bone resistance and an increase in fracture risk. World Health Organization (WHO) estimations are about 6.3 millions of femoral neck fractures in the world by 2050. These estimations make osteoporosis a real problem in term of public health.

Knowledge in biological tissues mechanical behaviour and its evolution with age are important for the design of diagnosis and therapeutic tools. From the mechanical aspect, bone resistance is dependent on bone density, bone architecture and bone tissue quality. If the importance of bone density and bone architecture has been well explored, the bone tissue quality still remains unstudied because of the lack of biomechanical tools suitable for testing bone at this microscopic dimension.

Therefore the goal of this study is to estimate the osteoporotic cancellous bone tissue mechanical behaviour at its microscopic scale, using an approach coupling mechanical assays and digital reconstruction.

Materials and methods

The experimental study is based on cancellous bone tissue extracted from human femoral head. Forty 8mm diameters bone cylinders have been removed from femoral head explanted after a femoral neck fracture treated by arthroplasty. These cylinders have been submitted to a digitally controlled compressive trial. Before and after the trials, microscanner analyses with an 8 μm spatial resolution have been realized in order to determine the micro structural parameters. The cylinders have been rebuilt with the digital model-building in order to estimate the mechanical behaviour and the bone quality.


Philip Pastides Sam El Sallakh Charalambides Charalambides

The aim of our study was to compare the clinical versus radiological diagnosis of patients suffering from a Morton's neuroma. Clinical assessments and pre operative radiological imaging of patients who underwent operative procedures for an excision of a Morton's neuroma were retrospectively compared. This review included 43 excised Morton's neuromas from 36 different patients over a period of 68 months, performed by one surgical team.

The commonest clinical symptoms were those of pain or tingling on the plantar aspect of the affected webspace on direct palpation (100%), pain of weight bearing (91%) which was relieved by rest (81%) and pain on stretching the toes (79%). The most sensitive clinical sign was a Mulder's click.

Our results showed that clinical assessment was the most sensitive method of diagnosing these neuromas (98%). All of our patients had at least one mode of radiological investigation. Ultrasonography was the commonest requested single imaging modality in our series. It was found to have a sensitivity of 90% (28/31). This imaging technique has the disadvantage of being operator dependant, as highlighted by the fact that one of our patients had a correct radiological diagnosis after a repeat ultrasound to the affected area was requested. Magnetic Resonance Image scan is a more expensive technique as it has the advantage of producing static reproducible images. As a single imaging modality, it was found to have a sensitivity of 92% (12/13) in our series. 3 patients had both imaging modalities; initial ultrasound failed to convincingly diagnose a neuroma in 2 cases and in the other case, the initial MRI did not show any pathology. In all these cases, the repeat imaging techniques confirmed the clinical diagnosis.

We conclude that there is no absolute requirement for ultrasonography or magnetic resonance imaging in patients who clinically are suspected to have a Morton's neuroma, as the clinical examination was found to be the most sensitive method of diagnosis. We suggest that the two main indications for performing some form of imaging is (a) an unclear clinical assessment and (b) cases when more than one webspace appears to be affected. An ultrasound of the webspaces should be the radiological investigation of choice, followed by a magnetic resonance scanning if any uncertainty still remains.


Alexandre Sitnik Alexandre Beletski Siarhei Kazayeu

AIM

SIGN-nail system was elaborated to reduce the need in image intensifier during IM-nailing and to allow use of this method in poor countries with restricted medical facilities. The aim of this study was to evaluate efficacy of SIGN-nailing in tibia fractures treatment.

MAT

119 patients with 120 tibia fractures were treated with SIGN nails from 2006 to 2009. Mean age 41.4±12.9 years (17–72). Closed fractures - 106, open - 14 (Gustilo I-6, II-6, III-2 III). Interval from the injury to operation: 6.24±7.9 days (0–45); 71.7% of patients were operated within a week after the injury. Closed reposition achieved in all but 7 cases. Manual reaming was performed in most cases, power -9, no reaming -8 cases. Distal locking was performed with use of supplied jig.


Michael Hughes Peter Kenyon Janardhan Rao

Intramedullary nails are a well accepted method of fixing fractures of the femur, however there are several potential complications associated with femoral nail insertion. One under-reported complication is perforation of the anterior cortex of the distal femur. Cortical perforation is well documented in immature bone however there is little evidence of perforation in skeletally mature adults.

We present a 5 year retrospective clinical audit into correct positioning of the TriGen™ intramedullary nail system (Smith & Nephew Inc.), with respect to determining the anterior cortex perforation rate. Cases were identified using searches of the electronic operation notes, followed by manual cross checking of the reference numbers of the implants used. The radiographs for each case were then checked to identify cases of distal anterior cortex perforation. 138 femoral nails were inserted over the 5 years 2005–2010 at our institution. 79 cases met the inclusion criteria, of which 8 were deemed to show radiological evidence of cortical perforation on lateral view, this represents a perforation rate of 10.1% in this population. There was also a significant difference in the mean age of the perforated vs non-perforated groups (80.1 vs 62.1 yrs respectively). These results are at odds with the current literature which reports few or no cases of cortical perforation. As a result of this audit we have made various recommendations for future practice. This study highlights a need for larger scale randomised trials to be carried out in the future.


Rolf Sobottke Jan Siewe Peer Eysel Karl-Stefan Delank

Introduction

Because it typically afflicts older patients with poorer health and/or risk factors, spondylodiscitis can become life threatening. Lingering symptoms, which can be attributed to residual destruction as well as concurrent degenerative changes in the adjacent segments after inflammation has subsided, are frequently present after both conservative and operative therapies. Here, quality of life outcomes are presented for patients two years after operative and conservative treatment.

Methods

82 patients with spondylodiscitis were included prospectively from 01/2008. 28% of patients were treated conservatively (Group 1) and 72% operatively (Group 2). Clinical findings, SF-36, ODI, COMI, and a visual analog scale (VAS) were evaluated and compared between the groups at admission and follow-up (2 year FU).


Hiang Boon Tan E Karadimas O Obakponovwe Nikolaos Kanakaris Peter Giannoudis

Introduction

The clinical and functional outcome following simultaneous fractures of the acetabulum and pelvic ring represent a challenge for the clinician and are currently obscure in the existing literature.

Patients and Methods

Between January 2003 and July 2009 all patients with combined pelvic and acetabular fractures were included in this prospectively study. Demographic details, mechanism of injury, ISS, surgical procedures, post-operative course, length of hospital stay, and radiological (Matta's score) and functional outcomes (The Merle d' Aubigne hip score) were recorded. The minimum follow up was 12 months (12–72).


Torsten Prietzel Mohamed Farag Martin Petermann Mathias Pretzsch Christoph-Eckhard Heyde

Aim

Our goals were to minimize the invasiveness of the revision hip arthroplasty approach in order to accelerate the patient's rehabilitation, shorten the length of hospitalization and reduce the postoperative complications, especially the rate of joint dislocation. Our study aimed to prove whether and under which conditions the less invasive approach is preferable in revision arthroplasty.

Material and Methods

The modified revision technique differs from the conventional approach in the following main aspects:

Oncologic: applying larger hip balls and inserts, after expanding the variety of the available articulating joint components in 4 mm steps (28–40 mm),

sparing and reconstructing the joint capsule, whereby the integrity of its acetabular origin is crucial.

That procedure was combined with tissue dissection strictly parallel to the direction of the muscle fibers. The transgluteal approach after Bauer was applied. The small skin incision was closed by running subcuticular technique. The inpatient postoperative phase after revision total hip arthroplasty was evaluated in the last 6.5 years. All patients completed a questionnaire.


Mercedes Gómez-Galván Maria Jose Bernaldez Rebeca Nicolás Manuel Quiles

In hallux valgus (HV), toe pronation is frequently seen, although there may be some with no pronation.

Aims

to evaluate big toe pronation in patients with HV with a clinical and radiographic method.

Material and methods

prospective study of 40 patients with HV on the waiting list for surgical treatment. Patients were standing barefoot on a rigid platform. Digital photographs were taken in a frontal plane to obtain the nail-floor angle formed by the secant line of toenail border and a line formed by the platform edge. All patients were evaluated using the AOFAS for HV and lesser toes, if they were affected. Personal and social data were obtained from clinical interviews. Charge radiographs were used to obtain HV, intermetatarsal and PASA angles, first metatarsal rotation as well as sesamoid bones displacement. Exclusion criteria: rheumatoid arthritis and previous intervention on foot or toes. Statistical analysis were performed with a multiple lineal regression.


Mats Molt Mats Molt Sören Tolsvig-Larsen

Introduction

When introducing new joint replacement designs, it is difficult to predict with any certainty the clinical performance of the new designs. Using roentgen stereophotogrammetric analysis (RSA) to evaluate the first two years of follow-up can serve as a predictor of late mechanical loosening for hip and knee prostheses. This prospectively randomized study was designed to evaluate the clinical performance of the Triathlon total knee system and compare the results between the two versions; posterior stabilized (PS) and cruciate retaining (CR).

Methods

Sixty patients were consecutively randomized (two patients left the study prior to surgery) to receive either the Triathlon total knee PS (30 patients) or the Triathlon total knee CR (28 patients). All components were cemented. The study was approved by the Ethical Committee for Lund University. All patients met the inclusion criteria. There were no statistically significant differences between the demographics for PS and CR. RSA was set to be the principal evaluation parameter. Patient outcome was assessed by the KSS and KOOS questionnaires.


Andrew Johnston Michael Stokes Ian Corry Richard Nicholas

Background

Anterior Cruciate Ligament Reconstruction is a commonly performed orthopaedic operation. The use of a four-strand semitendinosus and gracilis hamstring graft (STG) is a well established method of reconstruction to restore knee stability.

Aim

To assess the ten year subjective knee function and activity level following STG anterior cruciate ligament reconstruction.


Gowthaman Arumugam P Wraighte P Howard Shashikumar Nanjayan

Introduction

Acetabular bone deficiency presents one of the most challenging problems during revision hip arthroplasty. A variety of surgical options and techniques are available including impaction bone grafting. We present our medium to long-term experience of 68 consecutive hips in 64 patients who had acetabular revision using impacted cancellous bone grafting with bone cement with a mean follow up of 10.5 ±3.75) years (range 5.1 to 17.7 years).

Methods

Patients' undergoing acetabular bone grafting during revision hip arthroplasty prior to insertion of a cemented cup between 1993 and 2000 were evaluated. Pre-operative, immediate post-operative, 1 year post-op and final follow-up radiographs were evaluated. The pre-operative bone loss was graded according to the AAOS and Paprosky classifications. The presence of radiolucencies, alignment and incorporation of bone graft were evaluated. The Harris Hip Score (HHS) was used to assess clinical outcome.

13 patients who were unable to attend the department were contacted for a telephone interview. Analysis of the Data was carried out using SPSS17 [SPSS Inc. Chicago, Illinois]


Christian Merle Marcus Streit Moritz Inmann Tobias Gotterbarm Peter Aldinger

Introduction

Total Hip Arthroplasty (THA) in patients after proximal femoral osteotomy remains a major challenge. Inferior survival for both cementless and cemented THA has been reported in this subgroup of patients.

Methods

We retrospectively evaluated the clinical and radiographic results of a consecutive series of 48 THAs (45 Patients) who had undergone conversion THA for failed intertrochanteric osteotomy after a mean of 12 years (2–33 years) using a cementless, grit-blasted, double-tapered femoral stem. Mean follow-up was 20 years (range, 15–25 years), mean age at surgery was 47 years (range, 13–55 years). Clinical results were evaluated using the Harris Hip Score. Kaplan-Meier survivorship analysis was performed to determine long-term outcomes for different end points.


Susan Henriksen Ming Ding Soren Overgaard

Introduction

The combined incubation of a composite scaffold with bone marrow stromal cells in a perfusion bioreactor could make up a novel hybrid graft material with optimal properties for early fixation of implant to bone. The aim of this study was to create a bioreactor activated graft (BAG) material, which could induce early implant fixation similar to that of allograft. Two porous scaffold materials incubated with cells in a perfusion bioreactor were tested in this study.

Methods and Materials

Two groups of 8 skeletally mature female sheep were anaesthetized before aspiration of bone marrow from the iliac crest. For both groups, mononuclear cells were isolated, and injected into a perfusion bioreactor (Millenium Biologix AG, Switzerland). Scaffold granules Ø∼900–1500 μm, ∼88% porosity) in group 1, consisted of hydroxyapatite (HA, 70%) with -tricalcium-phosphate (−TCP, 30%) (Danish Technological Institute, Denmark). The granules were coated with poly-lactic acid (PLA) 12%, in order to increase the mechanical strength of the material (Phusis, France). Scaffold granules Ø∼900–1400 μm, 80% porosity) in group 2 consisted of pure HA/-TCP (Fin Ceramica, Italy). For both groups, cells were incubated in the bioreactor for 2 weeks. Fresh culture medium supplemented with dexamethasone and ascorbic-acid was added every third or fourth day.

Porous titanium alloy implants with diameter=length=10mm (Biomet, USA) were inserted bilaterally in each of the distal femurs of the sheep; thus 4 implants in each sheep. The concentric gap (2 mm) surrounding the implant was filled with 1) BAG (autogenous), 2) granules, 3) granules+bone marrow aspirate (BMA, autologous) or 4) allograft. The sheep were euthanized after 6 weeks. Distal femurs were removed and implant-bone samples were divided in two parts. The superficial part was used for mechanical testing and micro-CT scanning, and the profound part for histomorphometry. Push-out tests were performed on an 858 Bionix MTS hydraulic materials testing machine. Shear mechanical properties between implant and newly generated bone were calculated to assess implant fixation. Results were assessed by One-way ANOVA. P-values less than 0.05 were considered significant.


Salma Chaudhury Christopher Holland David Porter Fritz Vollrath Andrew Carr

Introduction

The pathophysiology of high failure rates following rotator cuff tendon repairs, particularly massive tears, is not fully understood. Collagen structural changes have been shown to alter tendon thermal and mechanical properties. Thermal changes in small biopsies, detected by differential scanning calorimetry (DSC) can help to quantify collagen structural differences in torn rotator cuff tendons. This study aimed to form a quantitative rather than qualitative assessment, of whether differences in collagen structure and integrity existed between small biopsies of normal, small and massive rotator cuff tears using DSC.

Methods

Thermal properties were measured for 27 human biopsies taken intra-operatively from normal, small, and massive rotator cuff tendon tears. 3 samples were taken from each patient and subjected to a modulated temperature ramp between 20–80°C at a rate of 2°C per minute with 0.318°C amplitude. The melting temperature (TM) is proposed to represent amide-amide hydrogen bond breakage and resulting protein backbone mobility. Denaturing temperature (TD) reportedly corresponds to the temperature at which the proteins fall out of solution. Denaturation enthalpy (H) should correlate with the amount of triple helical structure. Based upon a pre-study power calculation, this study had 90% power to detect a 10% difference in melting and denaturation temperature between groups with alpha=0.05.

1 specimen per patients was also frozen and cryosectioned and polarised light microscopy was used for quantitative validation. The effect of tear size on heat related parameters were performed using a one-way ANOVA test. A student's unpaired t-test was used to search for differences between individual groups (small tears, massive tears and normal tendons).


Antonio Pascarella Fabio Pascarella Carmine Latte Mariano Giuseppe Di Salvatore

Background

Jumper's knee is the result of violent and repeated contractions of quadriceps muscle caused by rapid acceleration and deceleration, jumping and kicking that load on patellar tendon stressing its mechanical resistance. The porpose of this retrospective study is to analyze the results, after the debridment of the patellar tendon and the patellar apex abrasion performed by arthroscopy, at a mean follow-up of seven years.

Methods

From 1996 to 2006, sixty-four patients (seventy-three knees) affected by jumper's knee underwent surgical tretment after failure of nonoperative treatment. All knees were operated on by the same surgeon using the same surgical technique: arthroscopic debridement of the articular face of patellar tendon and arthroscopic abrasion of patellar apex. Pre-operative and post-operative evaluation was made according to IKDC score, Lysholm Knee Scale and VISA-P score.


Robert Pflugmacher Koroush Kabir Rahel Bornemann Thomas Randau Dieter Wirtz

Background

Radiofrequency Kyphoplasty (RFK) provides a new minimally invasive procedure to treat vertebral compression fractures (VCF).

Purpose

The purpose of this study was to investigate the functional outcomes, safety and radiographic outcomes after the treatment of painful osteolytic vertebral fractures treated with a novel minimally invasive procedure, RFK.


Salma Chaudhury Zhidao Xia Philippa Hulley Andrew Carr

INTRODUCTION

There is increasing evidence for a multi-stage model of rotator cuff (RC) tendon tears, wherein healing is affected by tear size. The underlying pathophysiology however is not fully understood. Changes in the production and remodeling of the RC extracellular matrix (ECM) are likely to be important determinants of RC tendinopathy as they affect healing and the ability to bear loads. This study aimed to gain greater insight into size related tear pathogenesis by analyzing gene expression profiles from normal, small and massive RC tears.

METHODS

The genetic profiles of 28 human RC tendons were analyzed using microarrays representing the entire genome. 11 massive and 5 small torn RC tendon specimens were obtained from tear edges intraoperatively, and compared to 12 age matched normal controls. Semiquantitative real-time polymerase chain reaction (RT-PCR) and immunohistochemistry were performed for validation.


Hans Goost Thomas Karius Christoph Deborre Koroush Kabir Thomas Randau Christof Burger Dieter Wirtz Robert Pflugmacher

Introduction

Pedicle screw pullout or loosening is increased in the osteoporotic spine. Recent studies showed a significant increase of pullout forces especially for PMMA-augmentation. With application of conventional viscosity PMMA the risk of cement extravasation is associated. This risk can be reduced by using radiofrequency-responsive, ultrahigh viscosity bone cement.

Method

11 fresh-frozen lumbar vertebral bodies (VB) from 5 cadavers were collected and freed from soft-tissue and ligaments. By DEXA scan (Siemens QDR 2000) 8 VB were identified as severely osteoporotic (BMD 0.8 g/cm3), 3 VB were above this level. Two screws (6×45 mm, WSI-Expertise Inject, Peter Brehm, Weisendorf, Germany) were placed in the pedicles. Through the right screw 3ml of radiofrequency-responsive bone cement (StabiliT® ER2 Bone Cement, DFine, Germany) were injected via hydraulic cement delivery system (StabiliT® Vertebral Augmentation System, DFine, Germany). As control group, left pedicle screws remained uncemented. After potting the whole VB in technical PMMA (Technovit 4004, Heraeus Kulzer, Germany) axial pullout test was performed by a material testing device (Zwick-Roell, Zmart-Pro, Ulm, Germany).


Salma Chaudhury David Ferguson Osnat Hakimi Andrew Carr

INTRODUCTION

In order to address high failure rates following rotator cuff repairs, a greater understanding is required of the underlying structural changes so that treatments can be appropriately targeted and biomarkers of failure can be identified. As collagen is the primary constituent of tendon and determines force transmission, collagen structural changes may affect responses to loading. For example changes in collagen 1 and 5 are associated with the hyperelastic Ehlers-Danlos syndrome, which is diagnosed by looking for pathopneumonic altered collagen fibres or ‘collagen flowers’ in skin using transmission electron microscopy (TEM). To date no study has been performed on the microstructure of torn human rotator cuff tendons using TEM.

It was hypothesized that normal, small and massive human rotator cuff tendons tears will have altered microscopic structures. The unique study aimed to use TEM to compare the ultrastructure of small and massive rotator cuff tears, to normal rotator cuff tendons.

METHODS

Samples from 7 human rotator cuff tendons repairs were obtained, including 4 massive (>5 cm) and 3 small (< 1 cm) tears, and 3 matched normal controls with no history of connective tissue disorders. Specimens were fixed in 4% glutaraldehyde in 0.1M phosphate buffer, processed and examined blind using routine TEM examination.

To assess whether changes in the relative expression of collagen 1 and 5 (COL1A1, COL5A1 and COL5A2) occurred in all tears, qPCR was performed on another 6 phenotypically matched patients.


Hannah Oag Michael Daines Alexander Nichols Amit Kiran Nigel Arden Andrew Carr

INTRODUCTION

This study describes the prevalence of pain, functional loss and rotator cuff tears (RCTs) in a general population cohort. It is the first multidisciplinary assessment in such a cohort.

METHODS

The Chingford cohort is a 19-year old longitudinal population study comprising 1003 women aged between 44 and 67 at baseline. To date 183 consecutive subjects (366) shoulders have been interviewed about their shoulders. Myometric strength assessment and high-definition ultrasound examination (US) have been performed on all shoulders. Additionally pain thresholds and perceptions of pain have been tested using quantitative sensory testing (QST) and a number of validated questionnaires, including the illness attitudes scale and the pain detect score.


Lora Young Matthew Kent Nader Rehmatullah Adrian Chojnowski

Purpose

To analyse the early results of unconstrained pyrocarbon joint replacements in patients with osteo-arthritis of the metacarpo-phalangeal joints.

Background

Silicone arthroplasty, as introduced by Swanson in 1962 has remained the most popular procedure to treat arthritis of the metacarpo-phalangeal (MCP) joints. However, despite providing good pain relief, they have shown to demonstrate breakage rates up to 82% at 5 years. This is of great concern in the osteoarthritis (OA) patient group, who tend to be younger and have higher functional demands compared to their rheumatoid counterparts. The newer unconstrained pyrolytic carbon MCP joint prostheses may therefore be more suitable in OA patients whose soft tissue constraints are intact and whose hand function is strong. This study is the first to analyse the results of this implant in a cohort of OA patients only, with prospective data.


John Weston-Simons Hemant Pandit Ben Kendrick David Beard Max Gibbons William Jackson Harinderjit Gill Andrew Price Christopher Dodd David Murray

Introduction

The options for the treatment of the young active patient with unicompartmental symptomatic osteoarthritis and pre-existing Anterior Cruciate Ligament (ACL) deficiency are limited. Patients with ACL deficiency and end-stage medial compartment osteoarthritis are usually young and active. The Oxford Unicompartmental Knee Replacement (UKA) is a well established treatment option in the management of symptomatic end-stage medial compartmental osteoarthritis, but a functionally intact ACL is a pre-requisite for its satisfactory outcome. If absent, high failure rates have been reported, primarily due to tibial loosening. Previously, we have reported results on a consecutive series of 15 such patients in whom the ACL was reconstructed and patients underwent a staged or simultaneous UKA. The aim of the current study is to provide an update on the clinical and radiological outcomes of a large, consecutive cohort of patients with ACL reconstruction and UKA for the treatment of end-stage medial compartment osteoarthritis and to evaluate, particularly, the outcome of those patients under 50.

Methods

This study presents a consecutive series of 52 patients with ACL reconstruction and Oxford UKA performed over the past 10 years (mean follow-up 3.4 years). The mean age was 51 years (range: 36–67). Procedures were either carried out as Simultaneous (n=34) or Staged (n=18). Changes in clinical outcomes were measured using the Oxford Knee Score (OKS), the change in OKS (OKS=Post-op − Pre-op) and the American Knee Society Score (AKSS). Fluoroscopy assisted radiographs were taken at each review to assess for evidence of loosening, radiolucency progression, (if present), and component subsidence.


Mark Widemschek Georg Pfanner Reinhard Germann Thomas Benesch Roman Waibel Archibald Strempel Arno Martin

Background

In the literature are different data about the allogenic blood transfusion rate after total knee replacement. The common intention in orthopedic surgery is to reduce the requirement for allogenic blood transfusions by optimizing the blood management. The aim of this study is to determine the efficacy of the mechanical autotransfusion system OrthoPAT® to reduce the postoperative allogenic blood transfusion (ABT) rate.

Method

According to the preliminary performed power analysis we did a prospective controlled study including 151 patients which were randomized in a group A (OrthoPAT® for intra- and postoperative blood salvage and retransfusion, n=76 patients) and a control group B (no retransfusion system was used, n=75 patients). All patients had a primary osteoarthritis of the knee and were operated on without use of a tourniquet. We implanted in all patients a cemented posterior stabilized total knee prosthesis design. In group A the autotransfusion system was used for 6 hours (intra- and postoperatively) and the collected blood was retransfused. The retransfused blood was anticoagulated, filtered and centrifuged to separate waste products. Red cells were washed with saline and reconcentrated to a high hematocrit. The preoperative data for cardiopathy, angiopathy, preoperative anemia or anticoagulant treatment showed no significant differences for group A and B. Because of missing data we finally were able to use the results of 140 patients: 70 group A and 70 in group B. The indications for a blood transfusion were influenced by the clinical symptoms of anemia, the hemoglobin value (hemoglobin < 8.0 g/dl) and the anamnesis of cardiovascular diseases. Evaluation was done with the medical history and the pre-/postoperative hemoglobin values and postoperative need of allogenic blood transfusion.


Petros Antonarakos Anastasios Christodoulou Panagiotis Givissis Lamprini Katranitsa Panagiotis Simeonidis Achilleas Boutsiadis

AIM

Retrospective study comparing the effectiveness of preoperative autologous blood donation versus intra-operative blood saver systems in minimizing the need for allogeneic blood transfusion in scoliosis surgery.

MATERIALS – METHODS

Between 2003–2009, 37 of the patients (4–33, mean age 20y) who underwent scoliosis surgery, were divided in two groups. The first group (20 patients, mean age 18.7y) underwent autologous blood predonation, prerequisities were body weight over 50 kgr and Hgb above 11 mg/dl. The second group (17 patients, mean age 21.5y) consisted of patients who did not meet the above prerequisities and blood saver was used intra-operatively. Duration of surgery and perioperative Haemoglobulin (Hgb) levels were recorded in both groups.


Ola Rolfson Johan Kärrholm Leif Dahlberg Göran Garellick

In medical research and among health-care providers there has been a marked shift to a focus on patient-reported outcome (PRO) and how it is measured and analysed. In this study from the Swedish Hip Arthroplasty Register we present the development and results of a nationwide, prospective, observational follow-up programme including patient-reported outcome measures (PROMs). The programme started in 2002 and has gradually expanded to include all units performing THA surgery in Sweden. The self-administered PROM protocol comprises the EQ-5D instrument, the Charnley categorization and visual analogue scales (VAS) for pain and satisfaction. These current analyses include 34 960 THAs with complete pre- and one-year postoperative questionnaires.

Patients eligible for THA generally report low health-related quality of life (HRQoL) and suffer from pain. One year post-operatively the mean EQ-5D index increased from 0.41 to 0.78 (p<0.001) which is above the level of an age- and gender-matched population. Pain was reduced from mean VAS 62 to 14 (p<0.001). Females, younger patients and those with Charnley category C reported lower EQ-5D index pre-operatively than males, older patients and Charnley A or B, respectively, did (all p<0.001). In a multivariable regression analysis Charnley category C, male gender and higher age were associated with less improvement in HRQoL (p<0,001). Patients' response rates to the Registry was 86% pre-operatively and 90% one year post-operatively.

Nationwide implementation of a PROM programme requires a structured organization and effective IT solutions. The continuous collection of PROs permits local and national improvement work and allows for further health-economic evaluation.


Johannes Keck Karl-Philipp Kienle Klaus-Arno Siebenrock Simon Steppacher Stefan Werlen Tallal Charles Mamisch

Purpose

The purpose of this retrospective study was to investigate the acetabular morphology of pincer impingement hips in order to better understand damage pattern in these patients. We compared MRI measurements made at different postions from anterior to posterior on the acetbulum in patients with pure pincer type FAI to those made in patients with pure cam-type to collect parameters that may be useful in the diagnosis and classification of pincer impingement.

Material and Methods

From an initial consecutive retrospective population of 1022 patients that underwent MRI with clinical impingement signs 78 hips which were selected with as clear cam (n=57) or pincer (n=21) impingement on plain radiographics. On these MR Imaging was performed with a 1.5-Tesla system. For analysis, a lateral angle of overcoverage on coronal MRI (MR_LCE), the MR extrusion index and the alpha angle (after Nötzli) were used. In addition to these the gamma angle, the acetabular depth and the angle of lateral acetabular overcoverage were described clock-wise on 7 radial slides from anterior to posterior. These were compared between the cam and pincer population using students-t-test. Measurements were obtained by two observers and inter-observer variability was assessed.


Dirk Jan Moojen Gijs Van Hellemondt Charles Vogely Bart Burger Geert Walenkamp Niek Tulp Wim Schreurs Frank De Meulemeester Corrie Schot Takaaki Fujishiro Leo Schouls Thomas Bauer Wouter Dhert

Background

Both from experimental studies and the large arthroplasty registries there is evidence that bacteria are more often involved in implant loosening then is currently reported. To further elucidate this potential problem, the current study investigated the hypothesis that many total hip arthroplasty revisions, classified as aseptic, are in fact low-grade infections missed with routine diagnostics.

Methods

In 7 Dutch hospitals, 176 patients with the preoperative diagnosis of aseptic loosening of their total hip arthroplasty were enrolled. From each patient, the preoperative history was obtained. During surgery, between 14 and 20 tissue samples were obtained for routine culture, pathology analysis and broad range 16S rRNA PCR with reverse line blot hybridization (PCR-RLB). Samples were taken from the (neo-) capsule and acetabular and femoral interface tissue. Cultures were performed locally according to similar protocols. One specialized pathologist, blinded for all other results, analyzed all pathology samples. The PCR-RLB analysis was performed centrally, using a technique previously validated for orthopedic use. Patients were classified as not infected, suspect for infection or infected, according to strict, predefined criteria. Each patient had a follow-up visit after 1 year.


Dimitrios Nikolopoulos Neoptolemos Sergides George Safos Apostolos Karagiannis Stauros Tsilikas George Papagiannopoulos

BACKGROUND

Osteoporosis with subsequent osteoporotic vertebral compression fractures is an increasingly important disease due not only to its significant economic impact but also to the increasing age of our population. Pain reduction and stabilization are of primary importance with osteoporotic vertebral compression fractures.

OBJECTIVE

To compare the efficacy and safety of balloon kyphoplasty and vertebroplasty for the treatment of vertebral compression fractures.


Philippe Boisrenoult Hadrien Galey Nicolas Pujol Pierre Desmoineaux Philippe Beaufils

The bare area of the humeral head is limited in front by the cartilage and backwards by the insertion of the Infra Spinatus tendon. There are few references in the current literature. The aim of this work was to precise the anatomic description of the bare area and to compare the size of this area in patients with anterior shoulder instability and patients without anterior shoulder instability.

Material and method

We have proceeded first to an anatomic study to precise the limit of the bare area. The second part of this study was a retrospective and prospective comparative arthro CT-scan study in two groups of patients. The first group (group 1) had 48 patients, going to have anterior instability surgery. The second group (group 2) had 38 patients, without shoulder instability. Mean age was respectively 28.2 years (range: 19–48) in group 1; and 39.3 years (16–69) in group 2. The size of the bare area was measured on the axial injected CT cut passing by the larger diameter of the humeral head, The size of the bare area was definite by the angle between the line connecting the centre of the head to the posterior limit of the cartilage and the line connecting the centre of the head to the anterior point of the Infra Spinatus tendon. The reproducibility of the measure has been evaluated by a Bland and Altman test and an intra class correlation test. The measures were realised by two independent surgeons in a blind manner. The results where compared by a Student test with a threshold at 5%.

Results

In the anatomic part of this study, the average angle of the bare area was 32.7° equal to 13.7mm wide. Mean intraobserver variability was 4° (range: 0 to 20°) (NS) and mean interobserver variability was 4° also (range: 0 to 20°) (NS). Mean size of the bare area was 49.6° eaqual to 19.8mm wide [range 25° to 70°] in group 1 and 33.2° equal to 13.5mm wide [range 21° to 60°] in group 2 (p< 0,05).


Mark Brady Irene Sinz Amy Kinbrum Adam Briscoe

Introduction

Patients suffering from finger joint pain or dysfunction due to arthritis and traumatic injury may require arthroplasty and joint replacement. Single-part silicone-based implants remain the material of choice and most widely used option, although reports on their long-term clinical performance are variable. For trauma indications, patients have a high expectation of functionality necessitating the use of materials with high wear resistance and mechanical performance. A new proximal inter phalangeal (PIP) joint designed by Zrinski AG (Wurmlingen, Germany), comprising a self-mating carbon fibre reinforced polyetheretherketone (CFR-PEEK) coupling, may provide a suitable alternative. Here we describe the wear performance of the CFR-PEEK components in a PIP joint wear simulator and subsequent characterisation of the wear particles.

Methods

Four proximal and distal PIP components were milled (Zrinski AG) from CFR-PEEK (Invibio Ltd, UK) and subjected to wear testing (Endo Lab ® GmbH, Germany). The test was conducted at 37°C over 5 million cycles in 25% bovine serum (refreshed every 0.5 million cycles). The load was a static force of 63N applied at a frequency of 1Hz with a flexion/extension angle of ±40°. Wear rate was determined by mass loss from each component. Pooled serum samples from the wear simulator were subjected to protein digest and the remaining particulate debris isolated by serial filtration through 10μm, 1μm and 0.1μm filters. Particle size and morphology was subsequently determined by scanning electron microscopy (SEM) (Continuum Blue, UK).


Sinan Said Katriina Boecker Puhakka Svend Erik Christainsen Bent Lund Peter Faunoe Martin Lind

Introduction

Tunnelwidening in failed anterior cruciate ligament reconstruction (ACLR) can result in the staged revision procedures with a need for bone transplantation prior to revision reconstruction. Limited knowledge exist regarding to quality of different transplantation methods. The present study used CT-scanning to evaluate tunnel bone density after allogenic bone chips and bone cylinder transplantation.

We hypothesized that bone chips transplantation resulted in higher bone density than bone cylinder transplantation due to possible voids between individual cylinders in the tunnels.

Methods

The records of 24 patients operated for 1st stage revision ACLR from April 2003 to march 2010 were included in the study. twelve patients had their tunnels transplanted with bone chips and twelve patients with bone cylinders from allogenic femoral heads. Bone chips were created by fine bone milling and cylinders were extracted by 7–8 mm core drilling.

Bone density 3–4 months after transplantation were evaluated by CT scanning reconstruction slides with 5 mm intervals throughout the tunnel length using histomorphometry.


Athanasios Zacharopoulos Spyros Papanikolaou Ioannis Vezirgiannis Vasilios Kechagias Charis Cristodoulopoulos Christoforos Papadopoulos Ioannis Besikos Giorgos Xenos Spyros Moscachlaidis

Purpose

To evaluate the long term results of the use of a postoperative autologous blood reinfusion system in total knee arthroplasty.

Material and method

In a prospective study, 176 patients who underwent unilateral total knee replacement, during the period 2004–2008, were evaluated (study group or group A). In all these patients a reinfusion system of unwashed blood salvaged was applied, while supplementary homologous blood transfusion was performed when required. The admission of banked blood transfusion determined by haemoglobin value (<9mg/dL) and/or clinical signs (blood pressure, pulses, etc). The value of haemoglobin, haematocrite and platelets recorded preoperatively and the 1st, 5th and 15th day after operation. Results were compared with the material of our previous prospective randomized controlled study (control groups B and C), where in 60 patients, between the years 2002–2004, the effectiveness of postoperative autologous blood reinfusion had been proved.


Claus Löcherbach Arno Schmeling Andreas Weiler

Introduction

An accurate and reproducible tibial tunnel placement without danger for the posterior neurovascular structures is a crucial condition for successful arthroscopic reconstruction of the posterior cruciate ligament (PCL). This step is commonly performed under fluoroscopic control. Hypothesis: Performing the tibial tunnel under exclusive arthroscopic control leads to accurate tunnel placement according to recommendations in the literature.

Materials and Methods

Between February 2007 and December 2009, 108 arthroscopic single bundle PCL reconstructions in tibial tunnel technique were performed. The routine postoperative radiographs were screened according to defined quality criterions: 1. Overlap of the medial third of the fibular head by the tibial metaphysis on a-p views 2. Overlap of the dorsal femoral condyles within a range of 4 mm on lateral views 3. X-ray beam parallel to tibial plateau in both views. The radiographs of 48 patients (48 knees) were enrolled in the study. 10 patients had simultaneous ACL reconstruction and 7 had PCL revision surgery. The tibial tunnel was placed under direct arthroscopic control through a posteromedial portal using a standard tibial aming device. Key anatomical landmarks were the exposed tibial insertion of the PCL and the posterior horn of the medial meniscus.

During digital analysis of the postoperative radiographes, the centre of the posterior tibial outlet was determined. On the a-p view, the horizontal distance of this point to the medial tibial spine was measured. The distance to the medial border of the tibial plateau was related to its total width. On the lateral view the vertical tunnel position was measured perpendicularly to a tangent of the medial tibial plateau.


Athanasios Zacharopoulos Spyros Papanikolaou Ioannis Vezirgiannis Vasilios Kechagias Charis Christodoulopoulos Giorgos Xenos Spyros Moscachlaidis

Purpose

To evaluate the effectiveness of the perioperative erythropoietin administration, as an alternative to homologous banked blood transfusions, in total hip arthroplasty.

Material and Methods

In a prospective randomized, controlled study, 101 patients who underwent unilateral total hip replacement, during the period 2004–2009, were evaluated. In all these patients, the same surgical team applied the same surgical technique (hybrid THA) and they followed the same rehabilitation program. In 50 patients (group A or study group) we administered 40,000 units of erythropoietin subcutaneously one day before the operation followed by 40,000 units (sc) every 3 days in a total scheme of 4 doses. All these patients received intraoperatively one unit of homologous blood transfusion (1 unit/patient) and additional blood transfusions postoperatively when required. A control group of 51 patients (group B) received intraoperatively one or two units of homologous blood transfusion (1.35 units/patient), according to the volume of blood collected in the suction device and to the anaesthesiologists estimation, and also additional blood transfusions postoperatively when required. The admission of banked blood transfusion was determined by the haemoglobin value (< 9mg/dl) and/or clinical signs (blood pressure, pulse etc.). The values of haemoglobin, haematocrit and platelets were recorded preoperatively and the 1st, 5th, and 15th day postoperatively.


Philippe Adam Gilbert Taglang David Brinkert François Bonnomet Matthieu Ehlinger

Introduction

Locking nail have considerably improved the treatment of long weight bearing bones. However, distal locking needs experience and may expose to radiations. Many methods have been proposed to facilitate distal locking and improve safety. Recently, an external distal targeting device adapted to the ancillary of the Long Gamma Nail has been proposed. We report our experience with this device through a comparative series of distal lockings. Aim of this work was to assess feasibility and advantages brought about with this targeting device when considering time or dose of irradiation.

Material and methods

Two prospective series of 50 distal locking performed by an experienced surgeon have been compared. Two methods were compared: the classical freehand technique using a Steinmann rod with the image of rounded holes, and the external distal targeting device. The following datas were collected: technical difficulties with either technique, locking mistakes and duration of exposure to radiations.


Alexander Aarvold James Smith Edward Tayton Andrew Jones Adam Briscoe Stuart Lanham Doug Dunlop Richard Oreffo

Background

Skeletal stem cells (SSCs) have been used for the treatment of osteonecrosis of the femoral head to prevent subsequent collapse. In isolation SSCs do not provide structural support but an innovative case series in Southampton, UK, has used SSCs in combination with impaction bone grafting (IBG) to improve both the biological and mechanical environment and to regenerate new bone at the necrotic site.

Aims

Analysis of retrieved tissue-engineered bone as part of ongoing follow-up of this translational case series.


Philipp Kobbe Ingrid Hockertz Richard Sellei Heinrich Reilmann Thomas Hockertz

Sacroiliac screw fixation is the method of choice for the definitive treatment of unstable posterior pelvic ring injuries; however this technique is demanding and associated with a high risk of iatrogenic neurovascular damage. We therefore evaluated the outcome, complications, surgical and fluoroscopy time for unstable posterior pelvic ring injuries managed with a transiliac locked compression plate.

23 patients were managed with a transiliac locked compression plate for unstable posterior pelvic injuries at a Level I Trauma Center. 21 patients were available for follow up after an average of 30 months and outcome evaluation was performed with the Pelvic Outcome Score, which is composed of a clinical, radiological, and social integration part.

The overall outcome for the pelvic outcome score was excellent in 47.6% (10 patients), good in 19% (4 patients), fair in 28.6% (6 patients) and poor in 4.8% (1 patient). 15 out of 21 patients (71.4%) returned to their normal life, 3 patients (14.3%) were limited at work, and 3 patients (14.3%) were not able to return to work due to their disabilities. The social status was unchanged to the preinjury status in 19 patients (90.5%). 13 patients (62%) stated no changes in spare time and sports activities; 4 patients (19%) had minor and another 4 patients (19%) had major restrictions. The average operation time was 101 min and intraoperative fluoroscopic time averaged 74.2 sec. No iatrogenic neurovascular injuries were observed.

Posterior percutaneous plate osteosynthesis may be a good alternative to sacral screw fixation because it is quick, safe, and associated with a good functional outcome.


Young-Hoo Kim Jun-Shik Kim Jong-Hwan Joo Jang-Won Park

Background

No study compared the clinical results of the posterior-stabilized mobile-bearing knee with those of nonposterior-stabilized mobile-bearing knee in the same patients. The purpose of this study was to examine whether the clinical and radiographic results, range of motion, patients satisfaction, and complication rates would be better in the knees with a posterior-stabilized mobile-bearing knee than in the knees with a nonposterior-stabilized mobile-bearing knee.

Methods

One hundred and fourteen patients (mean age, 67.9 years) received a nonposterior-stabilized mobile-bearing knee prosthesis in one knee and a posterior-stabilized mobile-bearing knee prosthesis in the contralateral knee. Seven patients were men, and 107 were women. At the time of each follow-up (mean, 7.3 years; range, seven to 7.6 years), the patients were assessed clinically and radiographically.


Moataz El-Husseiny Shelain Patel Fahad Hossain Fares Haddad

AIM

Failure of a primary anterior cruciate ligament (ACL) reconstruction is associated with poor functional outcomes even after revision surgery. The aim of this study is to identify early predictors for failure, so that it may aid in recognition of at-risk patients.

METHOD

An observational study was conducted of 623 patients undergoing primary ACL reconstruction by a single surgeon over a 72 month period. Patient and procedure related parameters including age, gender, BMI, time to surgery, graft size, fixation methods, meniscal and chondral injuries, meniscal surgery, radiological parameters and post-operative IKDC scores. Logistic regression modeling was employed to identify those factors which were statistically significant for failure.


Simon Thompson Peter Reilly Roger Emery Anthony Bull

Background

Tears of the rotator cuff are a common pathology and poorly understood. Achieving a good functional outcome for patients may be difficult, and the degree of fat infiltration into the muscle is known to be a major determining factor to surgical repair and post operative function. It is the hypothesis of this study that the degree of retraction of the common central tendon as seen on MRI corresponds to the amount of fat infiltration classified according to the Goutallier grading System.

Methods

MRI scans of the supraspinatus were reviewed and two groups identified: no tear (NT) and full thickness tear (FTT). The following measures were taken: central tendon retraction (CTR) and the Goutallier Grade according to MRI. The difference between Goutallier grade between NT and FTT were measured using the Mann-Whitney test. The relationship between Goutallier grade and increasing amount of CTR was described using Spearman's rank correlation and differences assessed using Mann-Whitney tests.


Sulaiman Alazzawi Reza Mayahi Patrick Musonda Martyn Parker

Objective

The aim of this study was to determine the correlation between body weight and fracture union for displaced intracapsular fracture neck of femur treated by closed reduction and internal fixation.

Patients and methods

A total of 197 patients with displaced intracapsular fracture of neck of femur, all of whom have been treated with closed reduction and internal fixation, were studied. The mean age was 71 years and 79% were female. Patients were followed up until fracture endpoint (union or non-union) with minimum follow up of 200 days.


Richard Field Sulaiman Alazzawi Michael Field Nikolaos Bardakos Vera Pinskerova Michael Freeman

Introduction

Femorotibial malalignment exceeding ±3° is a recognised contributor of early mechanical failure after total knee replacement (TKR). The angle between the mechanical and anatomical axes of the femur remains the best guide to restore alignment. We investigated where the femoral head lies relative to the pelvis and how its position varies with respect to recognised demographic and anatomic parameters. We have tested the hypothesis of the senior author that the position of the centre of the femoral head varies very little, and if its location can be identified, it could serve to outline the mechanical axis of the femur without the need for sophisticated imaging.

Patients & Methods

The anteroposterior standing, plain pelvic radiographs of 150 patients with unilateral total hip replacements were retrospectively reviewed. All patients had Tönnis grade 0 or 1 arthritis on the non-operated hip joint. All radiographs were obtained according to a standardised protocol. Using the known diameter of the prosthetic head for calibration, the perpendicular distance from the centre of the femoral head of the non-operated hip to the centre of pubic symphysis was measured with use of TraumaCad software. Anatomic parameters, including, but not limited to, the diameter of the intact femoral head, were also measured. Demographic data (gender, age, height, weight) were retrieved from our database.


Tomonori Shigemura Shunji Kishida Junichi Nakamura Munenori Takeshita Makoto Takazawa Takeshi Miyasaka Yoshitada Harada Kazuhisa Takahashi

Introduction

The purpose of this study was to clarify the incidence of steroid-induced osteonecrosis among different collagen diseases and to evaluate the predictive factors for steroid-induced osteonecrosis in a prospective MRI study.

Methods

We prospectively used MRI to study 337 eligible collagen disease patients requiring corticosteroid therapy and succeeded in examining 1199 joints (hips and knees) in 302 patients with MRI for at least one year starting immediately after the onset of corticosteroid therapy, a one-year follow-up rate of approximately 90%. The underlying collagen diseases included systemic lupus erythematosus (SLE) in 687 joints and a variety of other collagen diseases in 512 joints.


Petr Nesnidal Jan Stulik Tomas Vyskocil Michal Barna Jan Kryl

PURPOSE OF THE STUDY

The anterior approach to the thoracic and lumbar spine is used with increasing frequency for various indications. With the advent of prosthetic intervertebral disc replacement, its use has become even more frequent and has often been associated with serious complications. The aim of this study was to evaluate vascular complications in patients who underwent anterior spinal surgery of the thoracic and lumbar spine.

MATERIAL

We performed a total of 531 operations of the thoracolumbar spine from the anterior approach. In 12 cases, after exposure of the body of the first or second thoracic vertebrae, we employed the Smith-Robinson technique to expose the cervical spine. We used sternotomy in six, posterolateral thoracotomy in 209, pararectal retroperitoneal approach in 239, anterolateral lumbotomy in 58 and the transperitoneal approach in seven patients. The aim of surgery was somatectomy in 190 patients and discectomy in 341 patients. Sternotomy and transperitoneal approaches were carried out by a thoracic or vascular surgeon and all the other procedures were done by the first author. The indications for spinal surgery included an accident in 171, tumour in 56, spondylodiscitis in 43 and a degenerative disease in 261 patients.


Petr Nesnidal Jan Stulik Jan Kryl Zdenek Klezl

PURPOSE OF THE STUDY

Occipitocervical fixation and spondylodesis is indicated in various cases of occipitocervical instability. The aim of this retrospective study was to evaluate the results of occipitocervical fixation at our institutions.

MATERIAL + METHODS

Between 1997 and 2007, a total of 57 patients underwent occipitocervical fixation (OC) there were 25 men and 32 women, from 4 to 77 years of age. 2 groups, group one - tying wires or cables and group two - screw-rod or screw-plate systems. Indications included trauma in 15, rheumatoid arthritis (RA) in 28, destruction due to psoriasis in one, tumour in eight, and congenital anomalies in five patients. The patients were evaluated at a final follow-up ranging between 12 and 132 months after the primary surgery (average, 42.7 months). Indications for surgery and the method and extent of instrumentation were recorded. The evaluation included pain and neurological deficit assessment, radiographic evidence of the stability of fixation and bone union and intra-operative and early and late post-operative complications.


Gershon Volpin Albert Gorski Leonid Lichtenstein Genadi Kirshner Jack Stolero Alexander Kaushanski Haim Shtarker Raviv Shachar

Introduction

Throughout the years treatment of patellar fractures have been held in much controversy and various treatment procedures have been described. In the literature, there are only a few studies that compare the results of the different treatment modalities.

Materials & Methods

This study reviews our experience with patellar fractures and correlates results of different treatment modalities to grade of patellar comminution and to the length of follow-up. It consists of 114 patients (71 M, 43 F, 17–76 year old: mean- 43 years), followed for 2–9 years (mean- 3.5 years). Patients were treated by P.O.P. cast for undisplaced fractures (12 Pts), and by various surgical modalities for displaced or comminuted fractures such as O.R.I.F (53 Pts), partial patellectomy (37 Pts) and total patellectomy (12 Pts). Patients were evaluated by Lisholm functional score, by objective knee tests, and radiographically.


Yuri Kulikov Nicholas Parsons Damian Griffin

Introduction

There is an ever increasing demand for Randomised Controlled Trials (RCTs) in Trauma and Orthopaedic Surgery. Patient recruitment is often challenging. Among other factors, individual surgeon's preference is often quoted as a major obstacle. Collective equipoise based on present or imminent controversy in the expert medical community has been proposed as a solution, but could not help in everyday running of a trial. We wanted to develop a new trial eligibility assessment tool using the Collective Equipoise Principle.

Methods

We developed an online system that quantifies collective uncertainty among a group of surgeons for an individual clinical case in real time. This data was collected for patients in the UK Heel Fracture Trial (UK HeFT) as an independent research project. Both patients who agreed or not to take part in the trial were approached in six weeks follow up clinic to avoid interference with clinical course. For those who agreed, anonymous clinical data together with images (Xrays and CT) was published on a secure on line forum and registered surgeons were alerted via email and SMS. Surgeons submitted their opinion instantly via specially designed interactive voting scale. 80:20 ethical uncertainty distribution limit was applied using Subjective Logic to calculate an Uncertainty Index (UnIx) for every patient. This approach was evaluated as an eligibility assessment tool for RCTs.


Dushan Thavarajah Turab Syed Martin Wetherill

Bone bruising of the scaphoid is a common term reported, when MRI imaging is carried out for continued pain, within the anatomical snuff box. Is this significant? Our aim was to ascertain if bone bruising lead to continued symptoms, and resulted in delayed fracture detection- an occult fracture. This was a prospective study looking at 170 patients with scaphoid injuries. Of the 170 scaphoid injuries identified there were 120 scaphoid fractures seen on scaphoid view radiographs. The remaining 50 had no fracture on radiographs, however were clinically symptomatic and had MRI scaphoid imaging which demonstrated various grades of bone bruising. All were treated in a scaphoid plaster and re-examined at 8 weeks. There 4 were patients that remained symptomatic, MRI scan were performed which revealed 3 with resolving scaphoid bone bruising and 1 with a scaphoid fracture (p-value=0.05). Two further weeks of immobilisation resolved the symptoms of those 4 patients. Therefore occult scaphoid fractures demonstrating only bone bruising may take up to 8 weeks to declare itself as a fracture. Immobilisation in a scaphoid cast should be the mainstay of treatment for a minimum period of 8 weeks.


Jordi Teixidor Serra Jordi Tomas Hernandez Sergi Barrera Daniel Pacha Vicente Lledo Batalla Gurrea Diego Collado Gastalver Vicente Molero Garcia Ainhoa Arias Baile Jordi Selga Joan Nardi Vilardaga Enric Caceres

Introduction and objectives

Intramedullary nailing is indicated to stabilization of tibia shaft fractures. Intramedullary nailing through an infra-patellar incision is commonly the technique of choice. While intramedullary nailing of simple diaphyseal fracture patterns is relatively easy, proximal tibia fractures, extremely comminuted/segmental tibia fractures, politrauma with multiple fractures in both extremities and reconstruction of bone loss segment with stiffness of the knee joint can be very challenging to treat.

A novel technique for intramedullary tibia nailing through the patella-femoral joint is described. This technique allow extension tibia during intervention time and it supplies easier reduction of the pattern of fracture above. The purpose of our investigation was to evaluate the use of this new technique in described above pattern fracture and patient situation; because we have thought that new technique can perform better outcomes in this situations.

Materials and Methods

An observational study of tibia fractures or bone defect was performed for consecutive patients who presented: proximal tibia fractures, extremely comminuted/segmental tibia fractures, politrauma with multiple fractures in both extremities and reconstruction of bone loss segment in the Trauma unit of our institution from September 2009 to August 2010.

A total of 32 were included in our study, which performed surgery intervention with Trigen tibia nail (Smith & Nephew, Memphis) with suprapatelar device.

Demographic data, mechanism of injury, fracture classification, ROM (2 and 6 weeks, and 3 months), consolidation rate, reduction fracture quality and knee pain at 3 months were recorded.


Helle Kristensen Ole Brink Rikke Thorninger Lars Borris Kjeld Andersen

Introduction

The purpose of the present study was to identify risk factors for lag-screw cut-out following osteosynthesis of intertrochanteric fractures.

Materials and methods

The study was a case-control study using a sex and age matched control group. The fractures were classified according to Evans and OTA/AO classifications. Operative treatment was performed using dynamic hip-screw or cephalomedullary nailing systems. All patients were followed for at least 3–4 months postoperatively. The following risk factors were assessed: fracture type, quality of reduction by blinded assessment using a visual analogue scale, tip-apex distance (TAD) according to Baumgaertner, lag-screw positioning and other relevant additional risk factors in terms of walking ability, osteoporosis, cardio-vascular disease, neurological disease, diabetes, obesity, alcohol consumption and smoking.


Enrico Visoná Arnaud Godenèche Laurent Nové-Josserand Lionel Neyton Marie-Béatrice Hardy Gianluca Piovan Roberto Aldegheri Gilles Walch

PURPOSE

We performed an anatomical study to clarify humeral insertions of coracohumeral ligament (CHL) and superior glenohumeral ligament (SGHL) and their relationship with subscapularis tendon. The purpose of our study was to explain the « Comma Sign » observed in retracted subscapularis tears treated by arthroscopy.

MATERIAL AND METHODS

20 fresh cadaveric shoulders were dissected by wide delto-pectoral approach. After removal the deltoid and posterior rotator cuff, we removed humeral head on anatomical neck. So we obtained an articular view comparable to arthroscopical posterior portal view. We looked for a structure inserted on subscapularis tendon behind SGHL. By intra-articular view we removed SGHL and CHL from the medial edge of the bicipital groove, then subscapularis tendon from lesser tuberosity. We splitted the rotators interval above the superior edge of subscapularis tendon and observed the connections between subscapularis tendon, CHL and SGHL.


Lukas Maansson Marianne Olsson

Primary total hip replacement (THR) surgery is a common procedure. Benchmarking studies in the last decade has shown that those patients have a substantial risk for blood transfusions. The orthopaedic department at Drammen Hospital had implemented a multimodal primary THR care pathway with a focus on minimising surgical trauma and negative trauma response. Neither blood salvage, autologuos blood predonation or erythropoietin has been used. We had reviewed 399 consecutive unselected cases with a mean age of 67 years (range 31–94). We performed a statistic analysis of pre- and postoperative haemoglobin level (g/l). A gender neutral 125 was used as cut point for anaemia. Preoperative haemoglobin level, mean 136 (SD 1.33), and postoperative haemoglobin, mean 113 (SD 1.41), showed an almost perfect Gaussian distribution. Eleven patients received 26 units of allogeneic blood in the first eight postoperative days. There had been a violation of transfusion policy in six of the eleven transfused patients. Mortality during the first 90 postoperative days was zero and 4 patients was readmitted due to cardiac disease during the first 90 postoperative days. All those readmitted due to cardiac disease had an haemoglobin level above 100 at discharge. By combining the Gaussian distribution of the postoperative haemoglobin level and a restrictive transfusion trigger (80 g/l), we calculated a two percent probability of transfusion. For the anaemic patients the calculated probability of transfusion were five percent. Applying a multimodal care pathway in primary THR almost abolish the need for blood transfusion without any preconditioning of anaemic patients. This study supports that an restrictive transfusion trigger are safe in an unselected total hip replacement patient population.


George Cox Peter Giannoudis Sally Boxall Conor Buckley Dennis Mcgonagle Elena Jones

Introduction

Iliac crest bone marrow aspirate (ICBMA) is frequently cited as the ‘gold-standard’ source of MSCs. Mesenchymal stem cells have been shown to reside within the intramedullary (IM) cavities of long-bones and a comparative assessment with ICBMA has not yet been performed.

Methods

Aspiration of the IM cavities of 6 patients' femurs with matched ICBMA was performed. The long-bone-fatty-bone-marrow (LBFBM) aspirated was filtered (70μm) and the solid fraction digested for 60min (37°C) with collagenase. Enumeration was performed via the colony-forming-unit-fibroblast (CFU-F) assay and using the CD45low CD271+ phenotype via flow-cytometry. Passaged (P2) cells were differentiated towards osteogenic, adipogenic and chondrogenic lineages with their phenotype assessed using flow-cytometry CD33 CD34 CD45 CD73 CD90 CD105.


Geert Meermans Roger Van Riet Ghislain Geurts Frederik Verstreken

Introduction

Biomechanical studies have shown that a long, centrally placed screw is favourable in scaphoid fracture fixation. A volar percutaneous transtrapezial approach was developed to facilitate central screw placement. The purpose of this study was to evaluate radiographic changes at the ST-joint at long term follow up in patients where this approach was used.

Method

Results were graded with use of the visual analogue scale (VAS) and modified Mayo wrist score. Radiographs of both hands, comprising an anteroposterior, lateral and 45 degrees pronated oblique view were obtained. Degenerative changes at the ST-joint were staged according to the modified Eaton & Glickel classification.


George Cox Dennis Mcgonagle Sally Boxall Conor Buckley Elena Jones Peter Giannoudis

Introduction

MSCs have long promised benefits of synthesising bone/cartilage, treating non-unions and potentially accelerating fracture repair. This potential has been tempered by MSC scarcity in the ‘gold-standard’ iliac crest bone marrow aspirate (ICBMA) and the resulting need to expand numbers via cell-culture. Culture of MSCs is time-consuming, expensive and results in cells with a reduced differentiation capacity.

The reamer-irrigator-aspirator (RIA) is an innovation designed to reduce intra-medullary (IM) pressures during reaming of long-bones via continuous irrigation and suction. Aspirated contents are passed via a coarse filter, which traps bony-fragments before moving into a ‘waste’ bag - from which MSCs have been previously isolated. We examined liquid and solid phases found in this ‘waste’, performed a novel digestion of the solid phase and made a comparative assessment in terms of number, phenotype and differentiation capacity with matched ICBMA.

Methods

The filtrate ‘waste’ bag from RIA reaming (6 patients) was filtered (70μm) and the solid fraction digested for 60min (37°C) with collagenase. MSCs were isolated from liquid & solid fractions and from 10ml matched ICBMA. Enumeration of MSCs was achieved via colony-forming-unit-fibroblast (CFUF) assay and flow-cytometry on fresh sample using CD45low, CD271+. MSCs were cultured by virtue of their plastic adherence and passaged in standard, non-haematopoietic media. Passage (P2) cells were differentiated towards osteogenic, adipogenic and chondrogenic lineages with their phenotype assessed with flow cytometry CD33 CD34 CD45 CD73 CD90 CD105.


George Grammatopoulos Hemant Pandit Stephen Mellon Sion Glyn-Jones Roger Gundle Peter Mclardy-Smith David Murray Harinderjit Gill

INTRODUCTION

Studies have suggested that there is a reduction in head-neck-ratio (HNR) associated with MoMHRA. A reduction in HNR at operation would decrease range of movement and increase impingement risk. Impingement could lead to 20 edge loading, increasing wear. Serum ion levels of Chromium (Cr) and Cobalt (Co) are surrogate markers of wear. Although acetabular component orientation has been shown to contribute to wear and PT development, the role of a decrease in HNR has only been highlighted in PT development. This study aimed to measure changes in HNR that occur at resurfacing and determine any gender- and component size-specific differences. In addition it aimed to determine whether changes in HNR could be associated with increased wear.

METHODS

84 patients (56M: 28F) with unilateral MoMHRA were included. The mean age at surgery was 57 years. The mean femoral component was 49mm. Components were considered small if <45mm, average if between 45–50mm and large if >50mm. Three designs were implanted; BHR, C+ and Recap. The average follow up was 4 years. All patients had Cr/Co levels measured at follow up. Patients were considered to have high ions if Cr and Co levels were 5.1ppb and 4.4ppb respectively.

Pre-operative HNR (HNRpre) and the post-operative HNR (HNRpost) were made from the respective pelvic radiographs. Assuming a 2mm thick cartilage layer, the HNR based on the diameter of the articular cartilage pre-operatively (HNRart) was calculated.

The immediate changes in HNR as a result of the operation were expressed relative to articular HNR pre-op:

HNRartpost=HNRpost–HNRart


Motomi Ishibe Satoru Kariya

BACKGROUND & AIM

Most previous studies found that the rate of dislocation following primary THA was 2 to 3 % on average. It is expected that minimally invasive (MI) THA has fewer dislocations after surgery because it causes less muscle damage. To ascertain the risk factors of dislocation, we conducted a retrospective study of the occurrence of dislocation after MI-THA in Japanese patients.

METHODS

From June 2003 when we began MI-THA to August 2010 primary MI-THAs were performed on 2,042 hips; 1,997 hips with mini-posterior approach (a mean incision of 7 cm) with the repair of posterior soft tissues and 45 hips with other approaches. The dislocation after MI-THA was studied with respect to age, sex, body mass index, the use of navigation system, femoral head size, cup size and approaches. The period of follow-up was from six weeks to seven years.


Raghu Raman Christopher Shaw Geoffrey Johnson Hemant Sharma Nicky Day Arup Dutta

Introduction

Viscosupplementation is used widely to provide symptomatic relief to patients with knee OA. This study aimed to compare the efficacy and safety of the standard (3×2ml) and single (1×6ml) dosing regimens of hylan G-F 20

Methods

Prospective, randomized, blinded (reviewers), comparative independent study. Inclusion criteria was OA knee pain e 60mm on a 100mm VAS; no prior intra articular (IA) injection. Patients were randomised to recieve 1 × 6mL or 3 × 2mL hylan G-F 20. Follow-up at 1, 6, 12, 26 and 52 weeks. Analgesics prohibited for 24 hours prior to follow-up assessments and NSAID_s for 26 wks. All adverse events (AE) were recorded. Primary outcome measure: Target knee pain (VAS) at 26 weeks. Secondary outcome measures included WOMAC, Oxford knee score, SF12


Semih Aydogdu Tugay Yagci Murat Sezak Hakki Sur

We aimed to investigate the effect of Seprafilm®, a synthetic biomembran, on the intra-articular adhesion formation in an experimental arthrofibrosis model.

Twenty male white rabbits were randomly allocated into two groups of 10 animals in each. A standard surgical procedure aiming at the development of arthrofibrosis and including medial parapatellar arthrotomy, lateral eversion of the patella, partial synovectomy and debridement of anterior of supracondylar area and patella joint surface by scalpel was performed on all rabbits' right knees. Group 1 rabbits served as controls, and in Group 2 rabbits a Seprafilm®, barrier placed into the described area. In both groups, after surgery, knee joint was immobilized by a no.5 wire suture passing from the ankle and groin and keeping the joint in 140° of flexion. At 6th week, all animals were sacrificed and adhesion formation was evaluated both macroscopically and histo-pathologically. All data were semi-quantified and analyzed statistically by Fisher's exact test.

While all rabbits in control group displayed different rates of adhesion macroscopically (62.5% severe, 25% moderate, 12.5% mild), none in the study group had it. The average macroscopic adhesion score was 2.5 ± 0.75 in control group, and 0 in Seprafilm® group. Histopathologic evaluation also revealed microscopic adhesion in all rabbits in control group, but none in Seprafilm® group. Fibroblast proliferation in Seprafilm® group (100% mild) was significantly lower than in control group (62.5% severe, 37.5% moderate) (p<0.05).

In conclusion, use of Seprafilm® as a mechanical barrier may be of value against the formation of arthrofibrosis in risky knees such as septic and traumatic ones.


Ida Helsoe Jens Tingleff Jes Lauritzen Henrik Joergensen

Aim

We studied the characteristics of patient attendances at the Camp Bastion Field Hospital in the peak period of clinical activity. It has been expected that the summer of 2009 in Afghanistan would cause increased battle intensity due to the Afghan presidential referendum. Furthermore it was expected that civilian casualties would make up an increasing share of the total number of patients.

Method

Data was collected retrospectively from medical records by an on-site researcher. Each attendance was counted as a separate activity; some patients attended the hospital more than once.


Pietro Ciampi Matteo Vitali Gianfranco Fraschini

The aim is to evaluate the effectiveness of pericardium patch as a tendon augmentation graft in the repair of massive rotator cuff tear. This is prospective study analysis of a consecutive series of 60 patients who underwent open repair of a massive rotator cuff tear with patch between 1999 and 2007. The inclusion criteria were: symptomatic with pain, deficit of elevation, not responsive to the physiotherapy, tear size (massive: 2 or more tendons), minimum follow-up of 2 years since surgery, active and motivated patients. All were assessed preoperatively with plain radiographs (anteroposterior and axillary views), ultrasound and NMR of the shoulder. The study group consistent of 60 patients (39 men and 21 women) with the mean age of was 66 years (range, 46–81). The mean duration of symptoms before repair was 18 months (range 3–48). Patients were assessed with UCLA score, visual analog scale (Vas scale) and ultrasound preoperatively, at 1 year, and at 3 years. The change in UCLA scores, Vas scale were analyzed with the paired Student's test, assuming a normal distribution of the total score. Satisfactory results were achieved in 49 patients: mean preoperative UCLA score improved from 9.3 to 16.9 at final follow-up.

For pain, the mean preoperative value of Vas scale was 9,1, postoperative mean value was 4.9. Range of motion and abduction power improved not significantly after surgery, although patients satisfaction levels were high. Imaging studies identified intact patch in 15 patients and patch detachment in 45. No adverse side effects (infection, rejection, allergy) were reported during the study period.

The results of our study suggest that patients (appropriately selected) with a massive full-thickness rotator cuff tear can be expected to have a pain relief after repair, but not a significantly improved of functional outcome.


Stefan Lakemeier Johannes Reichelt Christian Foelsch Susanne Fuchs-Winkelmann Markus Schofer Juergen Paletta

Introduction

Differing levels of tendon retraction are found in full-thickness rotator cuff tears. The pathophysiology of tendon degeneration and retraction is unclear. Neoangiogenesis in tendon parenchyma indicates degeneration. Hypoxia inducible factor 1(HIF) and vascular endothelial growth factor (VEGF) are important inducers of neoangiogenesis. Rotator cuff tendons rupture leads to fatty muscle infiltration (FI) and muscle atrophy (MA). The aim of this study is to clarify the relationship between HIF and VEGF expression, neoangiogenesis, FI, and MA in tendon retraction found in full-thickness rotator cuff tears.

Methods

Rotator cuff tendon samples of 33 patients with full-thickness medium-sized rotator cuff tears were harvested during reconstructive surgery. The samples were dehydrated and paraffin embedded. For immunohistological determination of VEGF and HIF expression, sample slices were strained with VEGF and HIF antibody dilution. Vessel density and vessel size were determined after Masson-Goldner staining of sample slices. The extent of tendon retraction was determined intraoperatively according to Patte's classification. Patients were assigned to 4 categories based upon Patte tendon retraction grade, including one control group. FI and MA were measured on standardized preoperative shoulder MRI.


Julian Gaskin Desiree Forde-Gaskin Lawrence Ajekigbe

Introduction

Flexor tendon injuries are quite common injuries. They can result in persisting functional deficit if not repaired and appropriately rehabilitated. We look at flexor tendon injuries over a period of 1 year and re-audited three years later.

Method

We audited all flexor tendon injuries that were treated at our institution and repeated the same audit three years after. We looked at various aspects of the injuries including the site injured, the zone of injury, other structures injured, the type of repair and material used as well as the rehabilitation regime.


Nina Lindfors Pekka Hyvönen Marko Nyyssönen Mikko Kirjavainen Jyrki Kankare Eero Gullichsen Jari Salo Nina Lindfors

Bioactive glasses (BAGs) are bone substitutes with bone bonding, angiogenesis promoting and antibacterial properties. The bioactive process leading to bone bonding has been described as a sequence of reactions in the glass and at its surface. Implantation of the glass is followed by a rapid exchange of Na+ in the glass with H+ and H3O+ from the surrounding tissue, leading to the formation of silanol (SiOH) groups at the glass surface. Due to migration of Ca2+ and PO43− groups to the surface and cystallization, a CaO-P2O5 hydroxyapatite (HA) layer is formed on top of the Si-rich layer. Finally, cell interactions with the HA layer subsequently initiate the bone forming pathway.

The rapid increase in pH and the subsequent osmotic effect caused by dissolution of the glass have been suggested to partly explain the antibacterial properties observed for BAGs. Comparing bactericidal effects of different BAGs, BAG-S53P4 has been shown to be the most effective, with the fastest killing or growth inhibitory effect. This antibacterial effect has been observed in vitro for all pathogens tested, including the most important aerobic and anaerobic pathogens, as well as very resistant bacteria.

In a multicentre study in 2007–2009, BAG-S53P4 was used as bone graft substitute in treatment of osteomyelitis. Eleven patients (nine males, two females) with a radiologically diagnosed osteomyelitis in the lower extremity (N=10) and in the spine (N-1) participated.

In the operation, the infected bone and the soft tissue were removed, and the cavitary bone defects were filled with BAG-S53P4 (BonAlive™, Bonalive Biomaterials Ltd., Finland). In four patients, muscle flaps were used as part of the treatment. Eight patients were treated in a one-stage procedure. Kanamycin granules were used in one patient and Garamycin granules (Septocol ®) in two patients.

Patient data were obtained from hospital patient' records until August 2010, resulting in a mean follow-up period of 29 months (range 15–43).

BAG-S53P4 was well tolerated; no BAG-related adverse effects were seen in any patient. The use of BAG-S53P4 as a bone graft substitute resulted in a fast recovery. Long-term clinical outcome was good or excellent in ten of eleven patients.

These primary results indicate that BAG-S53P4 can be considered as a good and usable material in treatment of osteomyelitis. After this study BAG-S53P4 has been used in several other patients with very promising results.


Andrew Cook Alan Howieson Martyn Parker

Introduction

Debate still exists as to the optimum method of fixation for subtrochanteric femoral fractures. Meta-analysis of studies comparing cephalocondylic nails with extramedullary implants for extracapsular hip fractures have suggested that further investigation is required in this area. We present the outcome of the largest series to date of subtrochanteric fractures treated by both methods and with a minimum of one year follow-up.

Methods

244 patients with a subtrochanteric femur fracture were treated at one centre over a 21 year period were prospectively studied. 75 were treated with an extramedullary fixation implant and 168 with an intramedullary nail. Surviving patients were followed up till one year from injury.


Konstantinos Ditsios Dorothea Kapoukranidou Achilleas Boutsiadis Athanasios Chatzisotiriou Maria Albani Anastasios Christodoulou

Purpose of this study is to create an experimental model of electrophysologic evaluation of the supraspinatus muscle on rats, after traumatic rupture of its tendon.

The population of this study consisted of 10 male Sprague Dawley rats weighting 300–400g. Under general anaesthesia we proceeded with traumatic rupture of the supraspinatus tendon and exposure of the muscle. The scapula was immobilized, and the supraspinatus tendon was attached to a force transducer using a 3–0 silk thread. A dissection was performed in order to identify the suprascapular nerve, which was then stimulated with a silver electrode. Stimulations were produced by a stimulator (Digitimer Stimulator DS9A) and were controlled by a programmer (Digitimer D4030). Fiber length was adjusted until a single stimulus pulse elicited maximum force during a twitch under isometric conditions. Rectangular pulses of 0.5 ms duration were applied to elicit twitch contractions. During the recordings, muscles were rinsed with Krebs solution of approximately 37 8C (pH 7.2–7.4) and aerated with a mixture of 95% O2 and 5% CO2. The output from the transducer was amplified and recorded on a digital interface (CED).

The following parameters were measured at room temperature (20–21 8C): single twitch tension; time to peak; half relaxation time; tetanic tensions at 10, 20, 40, 80 and 100 Hz; and fatigue index, which was evaluated using a protocol of low frequency (40 Hz) tetanic contraction, during 250 ms in a cycle of 1 s, for a total time of 180 s. The fatigue index value was then calculated by the formula [fatigue index=(initial tetanic tension − end tetanic tension) ∗ 100/(initial tetanic tension)]. In the end, the transducer was calibrated with standard weights and tensions were converted to grams.

The mean single twitch was 8.2, the time to peak 0.034 msec and the half relaxation time 0.028 msec. The strength of titanic muscle contractures was 5.7 msec at 10Hz and 17.7 at 100Hz. Finally, the fatigue index was calculated at 48.4.

We believe that electrophysiologic evaluation of the supraspinatus muscle in rats will help us understanding the pathology of muscle atrophy after rotator cuff tears and possibly the functional restoration after cuff repair


Ming Ding Soeren Overgaard

Introduction

Osteoporosis (OP), osteoarthrosis (OA), and rheumatoid arthritis (RA) are the most common age-related degenerative bone diseases, and major public health problems in terms of enormous amount of economic cost. RA is considered as a major cause of secondary osteoporosis. At late stage, OP often leads to skeletal fractures, and OA and RA result in severe joint disability. Over the last a few decades, much significant research on the properties has been carried out on these diseases, however, a detailed comparison of the microarchitecture of cancellous bones of these diseases is not available.

In this study, we investigated three-dimensional (3-D) microarchitectural properties of OP, OA and RA cancellous bone. We hypothesized that there were significant differences in microarchitecture among OP, OA and RA bone tissues that might lead to different bone quality.

Materials and Method

Twenty OP, fifty OA, and twelve RA femur heads were harvested from patients undergone total hip replacement surgery. Cubic cancellous bone samples (8∗8∗8 mm3) were prepared and scanned with a high resolution microtomographic system (vivaCT 40, Scanco Medical AG., Brüttisellen, Switzerland). Then micro-CT images were segmented using individual thresholds to obtain accurate 3-D data sets. Detailed microarchitectural properties were evaluated based on novel unbiased, model-free 3-D methods. For statistical analysis, one-way ANOVA was used, and a p<0.05 was considered significant.


Simon Steppacher Christoph Albers Moritz Tannast Klaus Siebenrock

Femoroacetabular impingement (FAI) is a pathologic condition of the hip that leads to osteoarthrosis. The goal of the surgical hip dislocation is to correct the bony malformations to prevent the progression of osteoarthrosis. We investigated the topographical cartilage thickness variation in patients with FAI and early stage osteoarthrosis using an ultrasonic probe during surgical hip dislocation.

We performed a prospective case-series of 38 patients (41 hips) that underwent surgical hip dislocation. The mean age at operation was 30.6 (range, 18–48) years. Indication for surgery was symptomatic FAI with 4 hips (10%) with pincer-type, 7 hips (17%) with cam-type, and 20 hips (73%) with mixed-type of FAI. Cartilage thickness was measured intraoperatively using an A-mode 22 MHz ultrasonic probe at 8 locations on the acetabular cartilage.

The thickest acetabular cartilage was found in the weight bearing zone (range 2.8–3.5mm), whereas the thinnest cartilage was in the posterior acetabular horn (1.0–2.2 mm). In all hips, cartilage was thicker in the periphery area compared to the central area. In the anterior and posterior acetabular horn, the anterior area, and the superior area (central parts) a significantly decreased cartilage thickness in pincer-type compared to cam-type of FAI was found (p<0.05).

Cartilage thickness shows topographical differences in all types of FAI with pincer-type of FAI having generally thinner cartilage than cam-type FAI. This is the first study measuring in vivo cartilage thickness in the human hip.


Rohit Dhawan Vikas Sharma

Aims

The aim of this study was to statistically analyse the incidence and distribution of forearm fractures in the adult age group (3rd–10th Decades) between 1997 and 2009.

Methods

Records of patients with forearm fractures were retrieved from the hospital audit department using the predetermined codes to identify patients. The data included total number of patients between 20 and 100 years who were either reviewed in the fracture clinics or admitted to the hospital with forearm fractures along with patient gender, age at the time of incident and time of the year the incident occurred. Incidence of total fractures per year and per each month in the year was calculated. The patients were divided into age groups between 2nd to 10th decades. Linear regression analysis was carried out to identify the relationship between fracture incidence and the age or time of the injury. Correlation coefficients(R) and r2 were calculated for all the regression analyses. Fractures were also classified according to the Orthopaedic Trauma Association (OTA) classification system. SPSS (version 16) and Microsoft Excel 2007 were used for statistics.


Miguel Hirschfeld Juan Ramon Cano Enacarnacion Cruz Enrique Guerado

Introduction

Hip fracture is a worldwide problem, not only as far as epidemiology is concerned but also regarding economical issues. Surgery is the current standard treatment. However owing to age, and patients co-morbidities complications are common. Surgical site infection is directly related to operative procedure, and surgeons' experience may be very important when making plans for outcome improvement. In this paper we study the role of hip surgeons versus general orthopaedic surgeons in relation to postoperative site infection. Operative hypothesis determines that hip surgeons have less infection rates than general orthopaedic surgeons. Null hypothesis that infection rates are rather the same.

Material and Methods

In a prospective controlled cohort study 820 patients presenting with a hip fracture were randomizelly operated on by a group of orthopaedic surgeons of the same Hospital Department. Patients were then classified according to surgeons adscription either to a Hip Unit (Group A=215 cases) or not (Group B=605). Variables studied included age, gender, treatment (osteosynthesis or joint replacement), co-morbidities (according to Charlson, s index), and infection rate. Fisher, and Ranksum statistical tests, and simple and multiple logistic regression, for univariate and multivariate, analysis was performed.


Full Access
Ion Carrera Laura Trullols Esther Moya Oscar Buezo Ana Peiró Isidro Gracia Joan Majó

INTRODUCTION

Limb salvage surgery is a common treatment for patients who suffer from bone tumors. In the case of pelvic tumors this creates a challenge for the surgeon and the treatment remains controversial because the oncologic complications like local recurrence, dissemination and orthopaedic ones, like infection, haemorrhage, and mechanical problems of reconstructions Tumors affecting the acetabulum are a challenge for the surgeon because of the impact in the function of the extremity. There are many reconstruction techniques described in the literature like prosthesis, allograft systems, arthrodesis, etc…, but still there is not a gold standard due to the poor functional results at long term follow up, and the associated complications of all techniques. In this study we show the experience in our center on pelvic reconstructions after tumors affecting the acetabulum area (zone II).

MATERIAL AND METHODS

We surgically treated 81 pelvic tumors from 1997 to 2009 following the Enneking and Dunham calssification attending to the localization of the tumor: Zone I 38 (iliac bone)Zone II 25 (acetabulum)Zone III 18 (pelvic branches)In zone II tumors we performed pelvic reconstruction in eight cases, with different type of prosthesis. In 5 cases we performed saddle prosthesis (group A) and in 3 cases we performed Coned-Stanmore Implants type prosthesis with sacro-iliac anchorage. The mean follow up of the serie was 3,5 years (1–6 years). In group A the mean follow up was 5 years and in group A and in group B the mean follow up was 1 year due to the recent implantation in our center of Coned type prosthesis for pelvic reconstruction. We evaluated our results with these two types of prosthesis.


Katherine Harvey-Kelly Nikolaos Kanakaris Mudassar Ahmad Oghor Obakponovwe Peter Giannoudis

Introduction

The aim of this study was to evaluate the health quality of life and return to sports activities following pelvic ring injuries.

Patients and Methods

Between January 2006–2007 patients treated in our institution with pelvic fractures were eligible to participate. Inclusion criteria were adult patients. Exclusion criteria were children and pathological fractures. Data recorded included demographics, injury mechanism, fracture pattern, Injury severity score (ISS), associated injuries, method of fixation, complications and functional outcome. Health related quality of life was assessed using the (EuroQol) and return to sports activities was evaluated using a return to sports questionnaire. The minimum follow up was 24 months (24–39)


Rahul Kotwal Nk Rath Vishall Paringe Kathleen Lyons Rhys Thomas

Introduction

The assessment of the accuracy of reduction of the ankle syndesmosis has traditionally been made using plain radiographic measurements. Recent studies have shown that computerized tomography (CT) scan is more sensitive than radiographs in detecting diastasis. The ethos has now therefore shifted towards CT scan assessment of the syndesmosis. There is however no validated method to scan the syndesmosis and measure it on the CT scans. This exposes the patient to significant radiation risk and also to anxiety from inappropriate interpretation from these scans.

The objectives of this research project are to investigate the current practice of CT scanning the syndesmosis at a University Hospital and to devise a new CT protocol to reduce radiation exposure to patients and to assist surgeons in interpreting the observations.

Methods

Research Ethics Committee approval was obtained. Current practice was evaluated. A new 5 cut CT protocol was devised. Starting at the level of the distal tibial plafond, 5 cuts were made proximally 0.5 cm apart. Accuracy of the syndesmosis reduction was assessed just above the distal tibial plafond. Both the injured and the normal sides were scanned 12 weeks post surgery. The normal side served as a control.


Amit Atrey Mark Edmondson Debra East Kim Miles Nigel Ellens David Butt Adrian Butler-manuel Julien Warshafsky Jerome Davidson

In this review, we present the data of one of the largest non-designer, mid- to long-term follow ups of the AGC.

We present a total of 1538 AGC knees during a 15 year period, of which 902 were followed up by postal or telephone questionnaire focused on Oxford Knee Scores, Visual analogues of function and pain and survival analyses performed. Mean length of follow up was 10.4 years.

85.7% of patients had an Oxford knee score of between 0 and 40, with 71.2% scoring between 0–30.

65.6% of patients responded with a Visual Analogue Score (VAS) of 0 or 1 at rest (minimum pain 0) and 53.9% reporting VA scores of 0 or 1 while walking.

87.5% of patients reported Excellent or good functional reports at final follow up and 90.3% reporting excellent or good pain control compared to per-operative levels.

Survival analysis confirms excellent survivorship.

This large cohort and multi-surgeon trial reproduces the excellent results as demonstrated by the designer centre (Ritter et al.). Mid to long term outcome sows excellent function and analgesia. Complication rates are low and the necessity for revision remains low.


Muhammad Choudhry Richard Boden Sabeen Akhtar Max Fehily

Background

Femoroacetabular impingement (FAI) may be a predisposing factor in progression of osteoarthritis. The use of hip arthroscopy is in its infancy with very few studies currently reported. Early reports show favourable results for treatment of young patients with FAI. This prospective study over a larger age spectrum represents a significant addition to this expanding field of minimally invasive surgery.

Methods

Over a twenty-two month period all patients undergoing interventional hip arthroscopy were recorded on a prospective database. Patient demographics, diagnosis, operative intervention and complications were noted. Patients were scored pre-operatively and postoperatively at 6 months and 1 year using the McCarthy score.


Olivier Borens Julia Steinrücken Ulrika Furustrand Andrej Trampuz

Objectives

Establishing the diagnosis of implant-associated infections is often difficult, because of variable clinical presentations and lack of uniform diagnostic criteria. Sonication of removed orthopedic devices was shown to have superior sensitivity and specificity for infection. We evaluated the value of microcalorimetry as a quick and reliable tool in the diagnosis of infection in sonication fluid from removed implants.

Methods

Between 10/2009 and 02/2010 we prospectively included all removed orthopaedic devices at our institution, which were subjected to sonication. Periprosthetic tissue cultures were performed as standard procedure. The removed device was sonicated in Ringer solution (40 kHz, 1 minute) and the resulting fluid was cultured and centrifuged (3000 × g, 10 minutes). The resulting pellet was resuspended in 3 ml tryptic soy broth for isothermal microcalorimetry (sensitivity of 0.25 μW). The detection time until increase of 20 μW was calculated. A 48-channel batch calorimeter (TA Instruments, New Castle, DE, USA) was used to measure the heat flow at 37°C controlled at 0.0001 °C.


Avadhoot Kantak Surendra Patnaik Mohan Lal Jila Nadjafi

Objective

Delayed radiographs are routinely done to help in diagnosis of occult scaphoid fractures. Our aim was to determine the diagnostic value of these late x-rays.

Methods

This is a radio-diagnostic study. We prospectively reviewed radiographs of 67 patients with injury to their wrists who presented with anatomical snuff box to the accident and emergency department.5 patients showed up a fracture of the scaphoid on trauma x-rays and they were excluded from the study. All patients had a radiograph on day of presentation as well as a delayed radiograph at a later date. The radiographs were standardized to include 4 scaphoid views. All the radiographs were reported independently by a consultant radiologist (JN) and a consultant orthopaedic surgeon (ML).


Hervé Hourlier Peter Fennema

Background

Thromboembolic disease is a common complication of total hip replacement (THR). The administration of postoperative anticoagulants is therefore highly recommended. The purpose of this study was to compare rivaroxaban with fondaparinux with regards to their safety and effectiveness for the prevention of venous thromboembolic events (VTE) after THR.

Methods

We conducted an independent prospective study comparing VTE prevention strategies in two successive series of patients (Groups A and B) undergoing elective unilateral THR. Group A (n=253) received fondaparinux daily 2.5 mg for 10 days, followed by tinzaparin 4500 IU daily for one month. Group B (n=229) received 10 mg rivaroxaban daily for 40 days without platelet monitoring.

All surgeries were performed by a single surgeon under general anesthesia using an active blood transfusion-sparing plan. In the absence of contraindications, patients received intra-operative administration of tranexamic acid to reduce postoperative bleeding.

Preoperative and postoperative hemoglobin levels were recorded at regular intervals. Bleeding events were documented. The bleeding index was calculated by adding the number of red blood cell units and the difference in the hemoglobin level (in g/dL) between the first morning after the day of surgery and the seventh postoperative day (POD 7). After 5 to 10 days, all patients underwent bilateral lower-extremity duplex ultrasonography to screen for deep venous thrombi. Any clinical symptoms of pulmonary embolism were evaluated with spiral computed tomography lung scans. Clinical evaluation to look for evidence of deep venous thrombi and pulmonary emboli was performed at eight weeks postoperatively.


Dimitrios Nikolopoulos Neoptolemos Sergides George Safos Apostolos Karagiannis George Papagiannopoulos

BACKGROUND

As life expectancy in the population rises, osteoporotic fractures are seen most frequently in the vertebral column. Percutaneous kyphoplasty is increasingly used for pain reduction and stabilization in these patients, but the efficacy, cost-effectiveness, and safety of the procedure remain uncertain.

OBJECTIVE

To clarify whether kyphoplasty has additional value compared with optimum pain treatment in patients with acute vertebral fractures.


Karen Andersen Anne Christensen Mette Petersen Birgitte Christensen Nielse Pedersen Kjeld Soballe

Background

Randomized, controlled trials (RCTs) are generally accepted as the “gold standard” for the provision of the most unbiased measures of the efficacy of interventions but are often criticized for the lack of external validity. We assessed the external validity of a RCT examining the efficacy of local infiltration analgesia (LIA) compared with continuous epidural infusion after total knee arthroplasty (TKA)

Methods

During a one-year period, all patients consecutively admitted for elective, unilateral, primary TKA were identified as potential participants. All underwent eligibility screening to determine who were eligible for participation in a randomized controlled trial. We investigated the distribution of preoperative characteristics and postoperative variables among excluded patients, non-consenters, and enrolled and randomized participants.


Hannah Smith Joseph Manjaly Taher Yousri Neil Upadhyay Stephen Nicol Hazel Taylor James Livingstone

Informed consent is vital to good surgical practice. Pain, sedative medication and psychological distress resulting from trauma are likely to adversely affect a patient's ability to understand and retain information thus impairing the quality of the consent process. This study aims to assess whether provision of written information improves trauma patient's recall of the risks associated with their surgery.

121 consecutive trauma patients were randomised to receive structured verbal information or structured verbal information with the addition of supplementary written information at the time of obtaining consent for their surgery. Patients were followed up post-operatively (mean 3.2 days) with a questionnaire to assess recall of risks discussed during the consent interview and satisfaction with the consent process.

Recall of risks discussed in the consent interview was found to be significantly improved in the group receiving written and verbal information compared to verbal information alone (mean questionnaire score 41% vs. 64%), p=0.0014 using the Mann-Whitney U test. Patient satisfaction with the consent process was significantly improved in the group receiving written and verbal information, 97.9% of patients reported that they understood the risks of surgery when they signed the consent form compared to 83.2% who received verbal information alone (p=0.01). The majority of patients who received written information reported finding it helpful (93.8%) and most of the patients who did not receive written information reported they would have found it useful had it been offered (66%).

Patients awaiting surgery following trauma can pose a challenge to adequately inform about benefits conferred, the likely post operative course and potential risks. Written information is a simple and cost-effective means to improve the consent process and was popular with patients.


Iulian Popa Dan Negoescu Dan Poenaru Cosmin Faur Sorin Florescu

BACKGROUND CONTEXT

Osteoporosis causes decreased bone mineral density, which predisposes to fragility fractures. Low-energy vertebral compression fractures are the most common type of osteoporotic fragility fracture. Prior studies have shown that only one-quarter of patients diagnosed with an osteoporotic fracture are referred or treated for osteoporosis.

PURPOSE

To identify the rate of recurrent fractures after vertebroplasty and after the conservative treatment for patients aged 50 years and older who sustained low impact vertebral compressions fractures over a 6-month period.


Radu Moldovan Claudia Lamas Luis Natera Juan Castellanos Eduardo Dominguez Joan Monllau

Purpose

Evaluation of our experience on the treatment of comminuted, radial head fractures, and of the outcomes of pyrocarbon prosthetic replacement in such cases.

Materials and Methods

We evaluated 47 cases of prosthetic replacement, performed from May 2003 to July 2008. There were 18 males and 29 females with an average follow-up of 48 months (12 to 60). The Hotchkiss classification was used to characterize the fractures. The indicators for the procedure were type III fractures in 27 cases, type IV fractures in 10 cases, comminuted radial head fractures (associated with disruption in medial collateral ligament) in 3 cases, Monteggia variant in 5 cases, and Essex Lopresti in 2 cases. Functional outcomes were assessed using the Mayo Elbow Performance Index and the Visual Analog Scales (VAS) of pain, joint motion, and stability.


Vikas Sharma Rohit Dhawan

Aims and objectives

The aim of this study was to assess the radiographic outcome by using Lindstrom grading for the management of Malone 2A and 2B fractures by 3 different methods of treatment. The three different methods included manipulation under anaesthesia, k-wire fixation and open reduction internal fixation.

Methods and materials

Between March 2006 and February 2007, 62 intra-articular distal radius fractures were retrospectively selected. 31 patients including 21 females and 9 males with an average age of 62 years were classified as Malone 2A fractures and 32 patients including 18 females and 14 males with an average age of 64.5 years were classified as Malone 2B fractures. 18 patients had manipulation under anaesthetic (MUA) and immobilisation in a plaster of paris (POP) cast, 27 patients had manipulation and k-wire fixation and 17 patients had open reduction internal fixation (ORIF) of the fractures. All the patients had radiographic assessment at 6 weeks post op using Lindstrom grading. Grade 1 and 2 were considered acceptable, grade 3 and 4 were considered unacceptable.


Rohit Dhawan Vikas Sharma

Aims and objectives

The aim of this study was to statistically analyse the calcaneal fractures occurring in the community and distribution within the various age groups divided into decades.

Methods and materials

Records of calcaneal fractures were retrieved from the audit department of the hospital using the various codes to identify patients reviewed in the clinics or admitted to the hospital between 1997 and 2009. The data collected included the total number of calcaneal fractures, total number in either gender, age at the time of incident, month of the year the incident occurred. Annual distribution of incidence of forearm fractures was calculated for every year and every month of the year. The age of the patients was divided into decades. Linear regression analysis and correlation coefficients were calculated between the incidence of fractures and different variables including age, gender and the time of the injury.


Fatih Kucukdurmaz Vedat Uruc Abdullah Cingu Emrah Sayit Ihsan Ozdamar

Objective

Surgical treatment of trigger finger is usually performed as an outpatient surgery under local anesthesia n this study we present our results of surgical treatment of trigger finger performed with an ophthalmic knife which is less invasive for patient and easer for surgeon.

Material and Method

19 gauges microvitreoretinal ophthalmic knifes have a rhombus like edge with both sharp sides. The length of the knife's cutting side is 3 mm at each side. There were 40 women and 10 men with a mean age of 51.7 ± 5.7 (min: 40 max: 62). The thumb was involved in 32, the index finger in 10, and the middle in 8 patients. The procedure can be performed as an outpatient surgery under local anesthesia. The surface landmarks of the proximal and distal edges of the A1 pulley are marked on the skin. Percutaneous placement of a 25-gauge needle 5mm proximal to the PDC marked the distal extent of the release. The duration of procedure was under five minutes. Clinical examination was repeated on the postoperative 3rd day, 10th day and patients were re-examined or spoken to by telephone at a mean follow-up of 6.4 months.


Karlmeinrad Giesinger Piers Yates Karl Stoffel Lukas Ebneter Robert Day Markus Kuster

Introduction

Periprosthetic femur fractures are a serious complication after hip replacement surgery. In an aging population these fractures are becoming more and more common. Open reduction and plate osteosynthesis is one of the available treatment options.

Objective

To investigate hip stem stability and cement mantle integrity under cyclic loading conditions after plate fixation with screws perforating the cement in the proximal fragment.


Oliver Chan Melanie Coathup Karin Hing Tom Buckland Charlie Campion Gordon Blunn

INTRODUCTION

Autologous bone grafts are considered gold standard in the repair of bone defects. However they are limited in supply and are associated with donor site morbidity. This has led to the development of synthetic bone graft substitute (BGS) materials, many of which have been reported as being osteoinductive. The structure of the BGS is important and bone formation has been observed in scaffolds with a macroporous morphology. Smaller pores termed ‘strut porosity’ may also be important for osteoinduction. The aim of this study was to compare the osteoinductive ability of one silicate-substituted calcium phosphate (SiCaP) with differing strut porosities in an ectopic ovine model. Our hypothesis was that SiCaP with greater strut porosity would be more osteoinductive.

METHODS

The osteoinduction of SiCaP BGS with two different strut porosities (AF and AF++) was investigated. The materials had an identical chemical composition and morphological structure but differing strut porosity (AF=22.5%, AF++=47%). Implants were inserted into the paraspinal muscles in skeletally mature sheep. Procedures were carried out in compliance with UK Home Office regulations. There were 12 implants in each group. Implants remained in vivo for 8 and 12 weeks and on retrieval were prepared for undecalcified histology. Sections were stained and examined using light microscopy. A line intersection method was used to quantify bone, implant and implant surface/bone contact within seven random regions of interest along each implant. A Mann-Whitney U test was used for statistical analysis where p values < 0.05 were considered significant.


Bernard Stulberg David Covall Jay Mabrey Albert Burstein Laurent Angibaud Keisha Smith Jayson Zadzilka

Introduction

While clinically successful for decades, CR TKA is persistently compromised by inconsistent PCL function. Problems of mid-flexion instability, incomplete knee flexion, erratic kinematic behavior and posterior instability, not seen with PS devices, raise concerns about the consistency of the technique, and the devices used. Most TKA systems offer at least 2 different geometries of tibial inserts to address this clinical problem.

We hypothesize these problems are a result of compromise of PCL anatomy. To avoid compromise to the PCL 3 steps are required: 1) The slope of tibial resection must be less than 5°; 2) the depth of tibial resection must be based off the insertion footprint of the PCL, not the deficiencies of the tibial articular surface; and 3) the tibial insert must be modified to allow intraoperative balancing of the PCL.

Results

The CR Slope ™ implants and technique (Exactech) (“Posterior Cruciate Referencing Technique (PCRT)”) reflect this philosophy and have allowed consistent surgical intervention without PCL release and without multiple inserts. We present data identifying, the footprint, and the instrument and technique modifications that allow for predictable identification of the depth and angle of resection. At 2 years post implantation in the first 100 patients implanted, the study group has demonstrated similar operative time, LOS and Oxford knee scores (OKS), while ROM averaged 5° greater, and time to achieved flexion was decreased.


Norberto Confalonieri Alfonso Manzotti

Introduction

The authors performed a short term prospective study of unicompartmental knee replacement (UKR) associated to patella-femoral arthroplasty (PFA) for the treatment of bicompartmental symptomatic knee arthritis. At the latest follow-up all the implants were matched to a similar computer assisted Total Knee Replacements (CAS-TKR) group implanted for the same indications. Hypothesis of the study was that this bicompartimental implants could achieve comparable outcomes to TKR with a more conservative surgery and a higher joint function.

Materials and Methods

19 cases of anteriomedial (12) or anterolateral (7) arthritis in 19 stable knees were prospectively involved in the study. All the knees underwent to a selective reconstruction using simultaneously both UKR and PFR using the same surgical technique. All bicompartmental implants were performed by the same surgeon. Surgical time, hospital staying and all intra and post operative complications were registered. At a minimum follow-up of 20 months, every single case was marched to a similar case where had been implanted a computer assisted cruciate retaining TKR. Criteria of matching were: sex, age, pre-operative range of motion and arthritis grade. In both the groups all the cases were assessed clinically using WOMAC, KKS and GIUM scores. All the knees were radiologically investigated using the same radiological protocol.


Sten Rasmussen Camilla Knudsen Soeren Skou Martin Gronbech Jens Olesen Michael Rathleff

Introduction

Delayed onset muscle soreness (DOMS) in the quadriceps is frequent in runners finishing a marathon race, and may result in several days of discomfort and pain. There is an increasing clinical evidence that noninvasive, pulsed electromagnetic field therapy (PEMF) can have physiological effect on inflammation and tissue repair. The purpose of this pilot study was to investigate the effect of PEMF on quadriceps muscle soreness in marathon runners and to use the data to calculate an appropriate sample size for a subsequent study.

Material and methods

The design was a randomized double-blind prospective study covering a 5 days period after completion of a beach marathon. After the marathon all 74 runners that completed the 42.195 km were asked to participate in the study. Forty-six agreed to enter the study and were block randomized into an intervention group or a control group. The intervention group received an active pulsed electromagnetic field device, and the control group received a sham device. The sham devices were used in exactly the same manner but produced no electromagnetic field. The active PEMF device does not produce heat or cause any sensation in the tissue allowing participants to be blinded to treatment. The pulsed electromagnetic field signals of a 2-msec burst of 27.12-MHz sinusoidal waves were repeated at two bursts per second. Peak magnetic field was 0.05 G, which induced an average electric field of 10 mV/cm in the tissue with an effect of 7.3 mW/cm3. All subjects were instructed to place the device on the most painful area of the quadriceps for 20 minutes four times a day. Pain intensity was measured three times a day with the Visual Analogue Scale (VAS) during a 90o squat with a self-administered questionnaire. Data were non-parametric and compared with a two-sample Wilcoxon rank-sum test.


Pietro Ruggieri Andreas Mavrogenis Giuseppe Ussia Andrea Angelini Elisa Pala Giovanni Guerra Gabriele Drago Mario Mercuri

Background

There is doubt regarding resection compared to curettage for pelvic metastases. Previous studies have reported that curettage is associated with decreased survival compared with wide resection, and have justified a radical surgical approach to achieve pain palliation and tumor control.

Aim

To evaluate the role of wide en bloc resection compared to curettage/marginal resection for patients with pelvic metastases. The rationale was that wide resection does not improve survival even in patients with solitary pelvic metastases.


Jagwant Singh Rohit Rambani Zaid Hashim Javed Mustafa Simran Marwah N Raghuraman H Sharma

Introduction

The policy of treating open fractures within 6 hrs can result in complex operations being performed under sub optimal conditions. The purpose of this study was to determine the association between time to initial debridement and rate of infection in high energy (Grade III) open fractures of Tibia.

Methods

Medical records of all patients presenting with open fractures were reviewed. The inclusion criterion were Gustillo III A, B and C open fractures of tibia. Time of injury, time of arrival to the hospital, time of initial debridement and subsequent soft tissue procedures were recorded. The primary outcome measure was a diagnosis of infection or osteomyelitis at one year. Secondary outcome measure was fracture union at one year.


Pietro Ruggieri Andrea Angelini Mario Mercuri

Introduction

Although various reports analyzed “en-bloc” excision of sacral tumors, there are still technical problems to improve protection of nerve roots, preserve surrounding structures and reduce intraoperative bleeding, maintaining the oncologic result. We present a new technique for sacral resection, with short term preliminary results, derived with modification from Osaka technique.

Methods

Seven patients were resected for their sacrococcygeal chordoma with the followed described technique. Two patients had previous surgery elsewhere. The sacrum is exposed by a posterior midline incision and complete soft-tissue dissection. Lateral osteotomies were performed through the sacral foramina using a threadwire saw and Kerrison rongeurs, to avoid sacral roots damage. After proximal osteotomy, the sacrum is laterally elevated and mobilized to allow dissection of presacral structures. Mean surgical time was 5 hours (range: 3 to 8). Mean blood loss was 3640 ml.


Jagwant Singh Simran Marwah Javed Mustafa A Platt G Barlow N Raghuraman H Sharma

AIM

Chronic osteomyelitis still remains challenging and expensive to treat inspite of advances in antibiotics and operative techniques.

We present our experience with free muscle flap after radical debridement of chronic osteomyelitis, performed as a single stage procedure.

METHODS

We retrospectively identified eight patients (5 Females) with mean age of 63 yrs (Range40–71 yrs) Case notes were reviewed for co morbidities, Pre and post treatment inflammatory markers (plasma viscosity and CRP) and clinical staging.

Mean follow up was 3 yrs (Range 1–6 yrs) All the patients were jointly operated by orthopaedic and plastic surgeons and underwent thorough debridement and muscle flap (Seven free flaps and one rotational flap) in the same sitting. All the patients were reviewed regularly by plastic and orthopaedic surgeons.

Seven patients had free Gracilis flap and one had Triceps flap.

Clinical assessment of reinfection was made on presence of erythema, wound discharge, pain and swelling. Primary outcome measure was resolution of infection.


Monika Huber Karl Zweymueller Felix Lintner

Background

Continual implant stability is an important factor for the long-term success of cementless hip replacements. The increasing lifespan of patients causes a higher frequency of osteoporosis which may result in implant loosening due to bone loss. This study aimed to evaluate stability of long living implants in patients with advanced age.

Patients and methods

Nine cementless stems made of Titanium-alloy including adjacent bone tissue obtained post mortem were evaluated by radiologic-microradigraphical, histological and morphometrical analysis. The percentage of the surface area covered by bone (BICI=bone implant contact index) was determined. The age of seven women and two men ranged between 81 and 92 years. The time in situ ranged between 10 and 20 years. From the entire length of the femora bearing implants 5 transverse segments were excised, dehydrated, embedded in methylmethacrylate. After the grinding procedure, the sections were evaluated by light microscopy and morphometrical analysis. The autopsy findings were recorded. Atherosclerosis and their related diseases were evident in all cases.


Jeffrey Spalazzi Todd Baldini Chad Efird Shaun Traub Elise Hiza Shane Cook Dana Rioux-Forker Eric Mccarty

Summary

Strong mechanical fixation is critical to the success of rotator cuff repairs. In this comparative study in cadaveric shoulders, single-tendon full-thickness supraspinatus tears were repaired using two different types of PEEK knotless suture anchors-ReelX STT (Stryker) and Opus Magnum PI (Arthrocare)-using a single-row technique in both instances. Cyclic testing was performed followed by loading until mechanical failure. No significant difference was observed in gap formation, measured as the distance between the supraspinatus tendon and bone at the repair site, during cyclic loading. However, the maximum load was statistically higher for repairs with the ReelX anchor.

Purpose

The objective of this study was to compare the gap formation during cyclic loading and maximum repair strength of single-row full thickness supraspinatus repairs performed using two different types of PEEK knotless suture anchors in a cadaveric model.


Georgios Drosos Konstantinos Blatsoukas Athanasios Ververidis Grigorios Tripsianis Pelagia Chloropoulou Theodora Gioka Dionisios-Alexandros Verettas

Aim

The aim of this prospective comparative study was to evaluate the serum levels of different cytokines in patients underwent total knee replacement (TKR) and received allogeneic blood transfusion, post-operative auto-transfusion or not transfused.

Material and Methods

This was a prospective non-randomized comparative study in 248 patients underwent TKR. Patient's demographic and clinical data including age, gender, body mass index (BMI), preoperative Hb value, complications were documented. The serum levels of IL-1b, IL-6, IL-8, IL-10, and TNF were measure pre-operatively, the 1st, 2nd, 3rd and 5th post-operative day. Patients were categorized in three groups; in Group 0 patients received no blood transfusion, in Group 1 patients received post-operative auto-transfusion and in Group 2 allogeneic blood transfusion was applied. Statistical analysis of the results was performed using repeated measures ANOVA.


Stuart Bell Peter Young Colin Drury Mark Blyth Bryn Jones Angus Mclean

Introduction

Total knee arthroplasty is an established and successful operation. In up to 10% of patients who undergo total knee arthroplasty continue to complain of pain [1]. Recently computerised tomography (CT) has been used to assess the rotational profile of both the tibial and femoral components in painful total knee arthroplasty.

Methods

We reviewed 56 painful total knee replacements and compared these to 59 pain free total knee replacements. Datum gathered from case notes and radiographs using a prospective orthopaedic database to identify patients. The age, sex, preoperative Oxford score and BMI, postoperative Oxford score and treatments recorded. The CT information recorded was limb alignment, tibial component rotation, femoral component rotation and combined rotation.


Alexander Kolb Catherina Chiari Alexandra Kaider Harald Zehetgruber Charlotte-Dorothé Schneckener Alexander Grübl

We present our results of cementless total hip arthroplasty with a tapered, rectangular stem made of titanium-aluminum-niobium alloy. This implant is used since 1979 with only minor modifications. The design of the femoral component achieves primary stability through precision rasping and press-fit implantation.

Between October 1986 and November 1987, two hundred consecutive patients (208 hips) underwent total hip arthroplasty with this tapered, rectangular stem. In all cases the acetabular component was a threaded cup made of titanium.

At a minimum follow-up of twenty years eighty-seven patients were still alive. Sixty-seven patients (69 hips) were available for clinical and radiographic follow-up. The probability of survival of the stem was 0.96 (95% confidence interval, 0.91 to 0.98) and that of the cup was 0.72 (0.62 to 0.80). The probability of survival of both the stem and the acetabular component with revision for any reason as the end point was 0.71 (0.61 to 0.78).

Two stems have been revised due to aseptic loosening. We found various degrees of osteolysis around the acetabular and femoral component (61,7%). At the time of the 20-year follow-up no stem was deemed at risk for loosening.

The key findings of our twenty-year follow-up are the very low rate of revisions of the femoral component and the low rate of distal femoral osteolysis associated with this stem. Our data show that femoral fixation of the stem continues to be secure at a follow-up of twenty years.


Schmidt-Rohlfing Bernhard Bernhard Schmidt-rohlfing Roman Pfeifer Nicole Heussen Hans-Christoph Pape

A wide variety of intra- and extramedullary devices for the treatment of trochanteric fractures has been described. The Percutaneous Compression Plate is a minimally invasive and extramedullary device, which requires two 2–2.5 cm long incisions with minimal dissection oft soft tissue on the lateral aspect of the proximal femur. Earlier studies indicated that internal fixation using the PCCP is associated with a decreased perioperative blood loss, reduced transfusion requirements, with less postoperative pain, more rapid mobilisation, and with a reduced incidence of collapse of the fracture when compared with the standard device Dynamic Hip Screw. Aim of this study is to analyze the risk factors for the occurrence of local complications after internal fixation of intertrochanteric fractures of the femur using a Percutaneous Compression Plate.

In a retrospective cohort study patients with trochanteric fractures who underwent internal fixation with a PCCP were included. We investigated the potential risk factors age, gender, experience of the surgeon as indicated by the numbers of surgical procedures with the PCCP device, stability of the fracture according to the AO/OTA classification, and co-morbidities of the patients according to the ASA classification. The operations were performed by ten different surgeons. All local complications which required re-operation were recorded. They included cutting out of the screw, loosening of the screw barrels, local haematoma, and infections. Logistic regression analysis was carried out to determine the risk factors for local complications.

The mean age of the 122 patients included in this study was 78.5 years. 87 patients were female (70.7 %), 36 patients were male (29.3 %). With respect to the stability of the fracture 64 trochanteric fractures (52.5%) were classified as stable according to the AO/OTA classification, whereas 58 (47.5%) were considered to be unstable. Of the total of 122 patients with 122 trochanteric fractures eleven underwent re-operation due to local complications (9 %). The most frequent complication was complete or imminent cutting out of the upper cervical screw (N=5; 4 %). In the multivariate logistic regression model the only statistically significant risk factor was the experience of the surgeon (p=0.0316; odds ratio=4.7; CI 1.1–19.4).

Our data indicate that the experience of the surgeon is a significant risk factor for the occurrence of local complications. The frequent use of this device seems to lower the re-operation rate.


Tobias Renkawitz Michael Koller Georg Bonnlaender Juergen Drescher Tobias Riederer Joachim Grifka Jens Schaumburger Phillip Lechler

Background

For some time, optimized perioperative pathway protocols have been implemented in orthopedic surgery. In our hospital an accelerated clinical pathway has been successfully in effect for several years, focused on safely decreasing patients' length of stay and increasing their function at the time of discharge. The aim of the present project was to evaluate whether a further optimization is even more promising regarding early postoperative outcome parameters.

Materials and Methods

Prospective, parallel group design in an Orthopaedic University Medical Centre. 143 patients, scheduled for unilateral primary total knee replacement (TKR) under perioperative regional analgesia were included. 76 patients received a Standard Accelerated Clinical Pathway (SACP). 67 patients received an Optimized Accelerated Clinical Pathway (OACP) including patient-controlled regional analgesia pumps, ultra-early/doubled physiotherapy and motor driven continuous passive motion machine units. Main measures were early postoperative pain on a visual analogue scale, consumption of regional anaesthetics, knee range of motion, time out of bed, walking distance/stair climbing, circumference measurements and Knee Society Scores of the operated leg. Patients in both groups were checked for a possible discharge by a blinded orthopedic surgeon on the 5th and 8th postoperative (po) day, using a discharge checklist including the KATZ Index of Independence in Activities of Daily Living, standard requirements for pain at rest/mobilization, walking distance and regular wound healing. A potential discharge was only approved if the patient was able to meet all six criteria from the discharge checklist. Re-admission within 6 weeks after discharge from hospital was registered.


Gregory Robertson Alexander Wood Joshua Bakker-Dyos Stuart Aitken Andre Keenan Charles Court-Brown

To describe the treatment and morbidity of lower limb (LL) football fractures in regard to returning to football in a known UK population at all skill levels.

All football fractures during 2007–2008 sustained by the Lothian population were prospectively collected with the diagnosis being confirmed by the senior author when patients attended the only adult orthopaedic service in Lothian. Patients living outside the region were excluded from the study. Patients were contacted in August 2010 to ascertain their progress in return to football.

There were 424 fractures in 414 patients. 366 fractures (86%) in 357 patients (86%) were followed up with a mean interval of 30 months (range 24–36 months). Of these 32% were sustained in the LL. 88% of LL injuries returned to football compared to 85% of upper limb (UL) fractures (p=0.4). 60% of LL patients were treated as outpatients. 35% were operated on −26% had ORIF and 9% IM Nailing. The most common LL fractures were Ankle 38%, Tibial Diaphysis 14%, 5th Metatarsal 11%, Fibula 9% and Great Toe 7%. Only one of the fractures was an open injury - Gustillo Class 1 2nd Phallanx Foot. Three of the 12 patients who underwent IM nailing required fasciotomy. One patient in the operative cohort developed a significant infection. The mean time for return to football for conservative treatment was 17 weeks (range 3–104 weeks), and for operative treatment 41 weeks (range 10–104 weeks). 91% of patients treated conservatively returned to football, compared to 84% of the operative cohort (p=0.3). 43% of patients had ongoing symptoms from their injury. 9% of the operative cohort required removal of metal work or further operative intervention. 83% of patients returned to the same level of football or higher following injury. Patients under 30 were 1.4 times more likely to return to sport than those over 30 (p<0.05).

We have previously demonstrated that football is the most common cause of sporting fracture(1), yet little is known about patient outcome following fractures. LL fractures are less common than UL fractures, and there is no difference in the proportion of patients returning to football following LL fractures and UL fractures. Over half of LL fractures are treated as outpatients and the incidence of open fractures is very low. There is no significant difference between the operative and conservative groups in their return to football. In the over 30 age group, sustaining a fracture may act as a catalyst to quit football. This may explain the higher non-return rate compared to the under 30 age group. 43% of patients perceive that they have ongoing problems with their fracture over 24 months post-injury reflecting the considerable morbidity of football-related fractures.


Scott Middleton Raymond Anakwe Paul Jenkins Margaret Mcqueen Charles Court-Brown

This study describes the long term clinical and patient reported outcomes following simple dislocation of the elbow.

We identified all adult patients treated at our trauma centre for a simple dislocation of the elbow over 10 years. 140 patients were identified and 110 (79%) patients were reviewed at a mean of 88 (95% CI 80–96) months after injury. This included clinical examination, the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire, an Oxford Elbow questionnaire and a patient satisfaction questionnaire.

Patients reported long-term residual deficits in range of movement. The mean DASH score was 6.5 (95% CI 4 to 9). The mean Oxford Elbow score was 43.5 (95% CI 42.2 to 44.8). The mean satisfaction score was 85.6 (95% CI 82.2 to 89). Sixty-two patients (56%) reported persistent subjective stiffness of the elbow. Nine (8%) reported subjective instability and 68 (62%) complained of continued pain. The DASH, Oxford Elbow and satisfaction scores all showed good correlation with absolute range of movement in the injured elbow. After multivariate analysis, a larger elbow flexion contracture and female gender were both independent predictors of worse DASH scores. Poorer Oxford Elbow scores and overall satisfaction ratings were predicted by reduced flexion-extension arc of movement.

Patients report good long term functional outcomes after simple dislocations of the elbow. These are not entirely benign injuries. There is a high rate of residual pain and stiffness. Functional instability is less common and does not often limit activities.


Alun Wall Alun Wall Syed Hassan Charalambos Charalambous

Approximately 30000 total knee replacements are performed annually in the UK. Standard practice is to obtain a radiograph during the initial post-operative period. We performed a retrospective review of 638 total knee replacements and found no significant complications were visible on post-operative radiographs. There were 4 cases of mild femoral notching. Cessation of initial radiographs could save the NHS two million pounds annually. We suggest check radiographs in the initial post-operative period are unnecessary and waste valuable resources which could be distributed elsewhere.


Jonathan Baxter Steve Emmett Timothy Barlow Matthew Costa

Introduction

The Patient Archiving and Communication System (PACS) has revolutionised the way that radiographs are stored and viewed in orthopaedic surgery. A recent advance has been the ability to upload images directly from the image intensifier to PACS. We postulated that this facility may reduce the need for post operative ‘check’ radiographs following many orthopaedic trauma procedures.

Patients and Method

We performed an audit of post-operative radiographs requested in our University Hospital over three time periods: 31 days immediately before the direct upload facility was introduced, 31 days immediately after and a 31 day period two months later. Details from the operating lists were cross-referenced with image intensifier records to identify cases where it had been used. PACS records were then checked to determine if these images were available to view and if a formal ‘check’ radiograph was performed in the period prior to discharge.


Bharat Mody

Over the last few decades, the All-Poly Monoblock Tibia has been relegated to a minimum use in the major healthcare systems of the western world. The main reason for this has been the perception that this tibial component is inferior in its ability to withstand stresses. This perception originated and subsequently gained ground, due to certain historical reasons, leading to the widespread use of the modular metal-backed tibial component despite a higher cost.

The recent economic downturn has enforced even the rich western healthcare systems to look for cost-effective solutions. The author works in India, where the society is still highly price-sensitive and takes value for money very seriously. Further, the routine ADL of the Indian population requires them to adopt high flexion postures such as cross-legged sitting and squatting. The author has used the All-Poly Tibia extensively, which is the most economical of tibial components. Further, he has developed a surgical technique which has resulted in his patients achieving high flexion (greater than 135 degrees) in more than 75% cases.

This paper presents the 10 year results of a series of 500 cases of Primary TKR in which the All-Poly Monoblock Tibia had been used. All the patients had cross-legged sitting activity as part of their ADL, thus presumably generating significant pressures on the joint surfaces. Of the original 500 cases, we could follow up 434 cases. We report a 96% survival rate of the implant in this series. There was not a single aseptic plastic failure. The revisions required were due to infection, peri-prosthetic fracture, and instability.

The message being conveyed in this paper is that the All-Poly Tibia is a very cost-effective solution in routine Primary TKRs, and is able to deliver excellent long-term results even in high stress situations like cross-legged sitting activity. It would offer a huge cost savings to the healthcare system if the Orthopaedic Surgeons start using this implant more frequently.


Saqib Javed Chris Peck Debbie Salthouse Michael Woodruff

Introduction

The concept of the golden patient (GP) was introduced to our busy teaching district general hospital, in April 2009, to improve trauma theatre start times following disappointing results from a previous in-hospital study. The GP is a pre-selected first patient on the following day trauma list who is medically fit with a clear surgical plan. The GP should have already been seen by an anaesthetist and be ready to be sent for by theatres early. It has been shown by others to improve operation start times and could be used to improve trauma services and meet clinical targets more readily.

Methods

This prospective study involved the collection of planned trauma lists with the designated GP over November and December 2009. Data was collected from the theatre logbooks, including patient demographics, theatre reception, anaesthetic and operation start times. This was compared with the pre-GP data (January and February 2009). Graphs showing the comparative mean start times between pre-GP and GP trauma lists, including the 95% confidence interval for the population mean were created. A two sample T test was used to evaluate significance between groups.


Geraint Thomas Munier Hossain A Monk Harinderjit Gill Sion Glyn-Jones J Andrew David Murray David Beard Na Epos Group

Introduction

Malalignment of some designs of stem is associated with an increased risk of aseptic loosening and revision. We investigated whether the alignment of the cemented polished, double-taper design adversely affected outcome, in a multicentre prospective study.

Methods

A multicentre prospective study of 1189 total hip replacements was undertaken to investigate whether there is an association between surgical outcome and femoral stem alignment. All patients underwent a primary THR with the Exeter femoral stem (Stryker Howmedica Osteonics, Mahwah, NJ) and a variety of acetabular components. The primary outcome measure was the Oxford hip score (OHS) and change in OHS at five years. Secondary outcomes included rate of dislocation and revision. Radiographic evaluation of the femoral component was also undertaken. The long axis of the Exeter femoral component and the long axis of the femoral canal were located, and the angle at the point of intersection measured. The cementing quality was determined as defined by Barrack et al. Radiolucent lines at the cement-stem and cement-bone interface in the five year radiographs were defined using the zones described by Gruen et al. Subsidence was measured as the vertical dimension of the radiolucency craniolateral to the shoulder of the stem in Gruen zone 1 as described by Fowler et al. Cement fractures were recorded.


Claudia Druschel Claudia Druschel Alexander Disch Ingo Melcher Norbert Haas Klaus-Dieter Schaser

Introduction

Primary malign tumors and solitary metastatic lesions of the thoracic and thoracolumbar spine are indications for radical en bloc resections. Extracompartimental tumor infiltration makes the achievement of adequate oncological resection more difficult and requires an extension of the resection margins. We present a retrospective clinical study of patients that underwent chest wall resection in combination with vertebrectomy due to sarcomas and solitary metastases for assessing the clinical outcome especially focusing on onco-surgical results.

Method

From 01/2002 to 01/2009 20 patients (female/male: 8/12; mean age: 52 (range of age: 27–76yrs)) underwent a combined en bloc resection of chest wall and vertebrectomy for solitary primary spinal sarcoma and metastatic lesions. The median follow-up was 20,5 (3–80) months. Histological analysis revealed 17 primary tumors and 3 solitary metastatic lesions. In the group of primary tumors 10 sarcomas, 1 giant cell tumor, 2 PNET, 1 histiocytoma, 1 aggressiv fibrous dysplasia, 1 pancoast tumor and 1 plasmocytoma were histologically documented. We included 1 rectal carcinoma, 1 breast cancer metastases and 1 renal cell carcinoma. All patients underwent a chestwall resection en bloc with multilevel (1/2/3/4 segments: n=4/6/6/4) hemi (n=7) or total vertebrectomy (n=13) with subsequent defect reconstruction. Reconstruction of the spinal defect following total resections was accomplished by combined dorsal stabilization and carbon cage interposition. The chest wall defects were closed with a goretex ® -patch. One patient also received a musculocutaneus latissimus dorsi flap.


Anna Rienmüller Thomas Guggi Fabian Von Knoch Tomas Drobny Stefan Preiss

Introduction

Patellofemoral complications remain a very common post-operative problem in association with total knee arthoplasty (TKA). As malrotation of the femoral component is often considered crucial for the outcome, we analyzed absolute rotational femoral alignment in relation to patellar tracking pre- and postoperatively and matched the results with the two year functional outcome.

Methods

Femoral rotation and component rotation was assessed by axial radiography using condylar twist angle (CTA). The lateral patellar displacement, patellar tilt and Insall-Salvati index were measured on conventional radiographs. All assessments were done pre-operatively and at 2-year follow up. The series included 48 consecutive TKA (21 men, 27 women) performed at a single high-volume joint-replacement-center in 2008. All operations were performed using a tibia first-ligament balancing technique without patella resurfacing. The implant used was a condylar unconstrained ultracongruent rotating platform design. Outcome was assessed using the international knee society score (KSS) and the Kujala Score for anterior knee pain.


Michael Zlowodzki Bryan Armitage Coen Wijdicks Philip Kregor Levy Bruce Peter Cole

Introduction

The most common treatment options for fixation of osteoporotic distal femur fractures are retrograde nails and locking plates. There are proponents of more elastic titanium plates as well as more rigid steel plates; No clear superiority of one over the other has been established. We aimed to evaluate the mechanical differences between stainless steel and titanium locking plates in the fixation of distal femur fractures in osteoporotic bone. We hypothesized that due to its higher elasticity titanium locking plates can absorb more energy and are therefore less likely to “cut” into the bone compared to stainless steel locking plates resulting in improved metaphyseal osteoporotic fracture fixation.

Methods

We used eight matched pairs of osteoporotic fresh-frozen human cadaveric femurs (age >70 years, all female). Within each pair we randomized one femur to be fitted with a Less Invasive Stabilization System (LISS-Titanium locking plate) and one with a Distal Locking Condylar Plate (DLCP-Stainless steel locking plate).

A fracture model simulating an AO 33-A3 fracture was created (extraarticular comminuted fracture) and specimens were subsequently subjected to step-wise cyclic axial loading to failure. We used an advanced three dimensional tracking system (Polhemus Fastrak) to monitor the movement of the distal fragment relative to the real time distal plate position allowing us to evaluate distal implant cut-out.


Rajeshkumar Kakwani N Cooke A Waton D Kok H Middleton L Irwin

Aim

The purpose of this study was to investigate the effects of plaster/splint immobilisation of the knee/ankle on driving performance in healthy individuals.

Methods & Materials

Twenty-three healthy drivers performed a series of emergency brake tests in a driving simulator having applied above knee plaster casts, below knee plaster casts, or a knee brace with increasing restriction.


Mohamed Farag Mohamed Ghanem Torsten Prietzel Georg Von Salis-soglio

Aim

In the last years, many short hip stem variants were developed, almost always sharing the principle of metaphyseal and proximal diaphyseal anchorage. In this study, we analyzed the midterm results after implanting short cementless hip stem of ESKA.

Methods

A total of 380 total hip replacements using the ESKA-short cementless stems were performed in a series of 340 patients between November 2002 till May 2008. The clinical and radiological evaluation of the patients was done in September 2008. The mean follow up was 37 months (3–54 months).


Amit Atrey Steven Corbett Paul Gibb Hagen Jahnich Julien Warshafsky

Accurate documentation of operative findings is a fundamentally important part of any procedure and forms part of the Royal College of Surgeons of England's guidelines to good care, especially to “ensure that there are legible operative notes (typed if possible) for every operative procedure.” However, many hospitals fall short of this guideline when it comes to arthroscopic procedures because of the difficulty in reproducing visually representative and easy-to-understand images. There is an inability to properly record and archive findings of arthroscopic procedures. We, along with the British Orthopaedic Association, have developed an interactive, free Web-based operative note template that allows the surgeon to draw findings on diagrams of the joints commonly undergoing arthroscopy, type the findings, and then print as many copies as required. The use of the forms has allowed for quicker, easier, and more accurate documentation of arthroscopic procedures. The forms can then be saved to a database and used as a research tool.


Seung-Baik Kang Hyuk-Soo Han Dong-Nyoung Lee

The purpose of this study was to validate the usefulness of SPECT/CT as an evaluation method for determining treatment and prognosis for patellofemoral cartilage lesions, based on MRI and arthroscopic findings.

From August 2009 to February 2010, SPECT/CT was performed on 80 patients (24 male and 56 female, average 53.3 years old) with chronic anterior knee pain who had no degenerative changes or patellar malalignment on plain radiographs. Radioisotope uptake findings on patellofemoral joint from SPECT/CT were classified into three grades by one nuclear medicine specialist. In the patients who demonstrated poor improvements after conservative treatments, MRI and arthroscopy were performed. Patellofemoral cartilage conditions under arthroscopic finding (ICRS grades) were compared with SPECT/CT grading.

In all cases, there were increased uptakes on patellofemoral joints. Eighteen cases showed low uptake (Group 1), 22 cases showed medium uptake (Group 2) and 40 cases high uptake (Group 3). At the follow-up examination after mean 1.7 months, 16 cases of Group 1 (89%), 14 cases of Group 2 (64%) and 28 cases of Groups3 (70%) responded positively to the conservative treatments. For those 22 cases showing poor improvement, MRI and arthroscopy were done. Damage or thinning of patellofemoral cartilage, subchondral cyst, edema and fissuring were observed in every case that underwent MRI. Every arthroscopic case was found that there was patellofemoral cartilage damage. Each of ICRS grade I and grade II was found in 2 cases from Group 1. Two cases of grade II, 4 cases of grade III, and 2 cases of grade IV were found in Group 2. Two cases of grade II, 4 cases of grade III, and 6 cases of grade IV were found in Group 3. There was significant difference in the success rate of conservative treatment between SPECT/CT grade 1 and 2 or 3. And there was significant association between SPECT/CT grade and ICRS grade (P=0.034).

SPECT/CT could be a useful modality in determining the treatment and prognosis for patellofemoral cartilage lesions compared with MRI and arthroscopic findings.


Bodil Samuelsson Per Hellström Amer Al-Ani Margareta Hedström

Background

Elderly patients with hip fractures are often malnourished and in a catabolic state upon admission to hospital. Waiting time for surgery is commonly unpredictable, and often more than 24 hours. Due to an assumed stress-induced delayed gastric emptying time with a possible associated risk of aspiration, fasting guidelines are the same as for other trauma patients. This leads to prolonged fasting time in these patients who are often metabolically compromised, with negative effects on post-operative recovery and prolonged hospital stay. The aim of this study was to investigate if 400 ml of a carbohydrate-rich beverage could be given to patients with a hip fracture 2–3 hours before surgery without carrying a risk of pulmonary aspiration.

Methods

The gastric emptying rate of 400 ml 12.6 % carbohydrate rich drink was investigated in ten elderly women with a hip fracture awaiting surgery. The emptying rate was assessed by an indirect method, the paracetamol absorption technique. Results were compared with two control groups of healthy persons.


Choon-Key Lee Eiji Itoi Seung-Jang Kim Jung-Sub Lee Kwang-Am Jung Su-Chan Lee Kuen-Tak Suh

Introduction

Many literatures regarding more specific tests to diagnose the supraspinatus tendon injuries and the best rehabilitation methods to strengthen the supraspinatus have been published. However, conflicting results have been reported. 2-deoxy-2-[18F] fluoro-D-glucose (FDG) positron emission tomography (PET) has been recently used to assess skeletal muscle activities in various fields.

Purpose

To evaluate & compare the metabolic activities of deltoid & rotator cuff muscles after the full-can & empty-can exercises using PET-CT.


Mudussar Ahmad Alagappan Sivaraman Amarjit Rai Amratlal Patel

Background

Distal tibial metaphyseal fractures pose many complexities. This study assessed the outcomes of distal tibial fractures treated with percutaneously inserted medial locking plates.

Methods

Eighteen patients were selected based on the fracture pattern and classified using the AO classification and stabilised with an AO medial tibial locking plate. Time to fracture union, complications and outcomes were assessed with the American Orthopaedic Foot and Ankle Society ankle score at 12 months.


Yijuan Xu Vibeke Rudkjoebing Ole Simonsen Christian Pedersen Henrik Schoenheyder Per Nielsen Trine Thomsen

Prosthetic joint infection is one of the most challenging complications of joint alloplasty and the diagnosis remains difficult. The aim of the study was to investigate the bacterial flora in surgical samples from 22 prosthetic patients using a panel of culture-independent molecular methods including broad range 16S rRNA gene PCR, cloning, sequencing, phylogeny, quantitative PCR (qPCR), and fluorescence in situ hybridization (FISH). Concomitant samples were cultured by standard methods.

Molecular methods detected presence of bacteria in samples from 12 of 22 patients. Using clone libraries a total of 40 different bacterial species were identified including known pathogens and species not previously described in association with prosthetic joint infections. The predominant species were Propionibacterium acnes and Staphylococcus epidermidis; polymicrobial infections were found in 9 patients. Culture-based methods showed bacterial growth in 8 cases with the predominant species being S. epidermidis. Neither anaerobic bacteria (including P. acnes) nor any of the species not previously described in implant infections were isolated. Additionally, 7 of the 8 culture positive cases were monomicrobial. Overall, the results of culture-based and molecular methods showed concordance in 11 cases (hereof 9 negative by both methods) and discrepancy in 6 cases. In the remaining 5 cases, culture-based methods identified only one species or a group of bacteria (e.g., coagulase negative staphylococci or coryneform rods), while culture-independent molecular methods were able to detect several distinct bacterial species including a species within the group identified by culture. A qPCR assay was developed to assess the abundance of Propionibacterium while S. aureus was quantified by a published S. aureus qPCR assay. These quantifications confirmed the findings from the clone library approach and showed the potential of qPCR for fast detection of bacteria in orthopedic samples. Additionally, both single cells and microcolonies were visualized using FISH and confocal scanning laser microscopy.

In conclusion, the molecular methods detected a more diverse bacterial flora in prosthetic joint infections than revealed by standard culture-based methods, and polymicrobial infections were more frequently observed. The pathogenesis of these microorganisms and their role in implant-associated infections needs to be determined.


Richard Sellei Simon Hingmann Matthias Knobe Phillip Kobbe Phillip Lichte Matias De La Fuente Frauke Schmidt Sabine Linke John Grice James Turner Hans Pape

Background

Overlooked compartment syndrome represents a devastating complication for the patient. Invasive compartment pressure measurement continues to be the gold standard. However, repeated measurements in uncertain cases may be difficult to achieve. We developed a new, noninvasive method to assess tissue firmness by pressure related ultrasound.

Methods

Decreased tissue elasticity by means of rising compartment pressures was mimicked by infusion of saline directly into the anterior tibial compartment of 6 human specimens post mortem. A pressure transducer (Codman) monitored the pressure of the anterior tibial compartment. A second transducer was located in a saline filled ultrasound probe head to allow a simultaneous recording of the probe pressure provoked by the user. The ultrasound images were generated at 5 and 100mmHg probe pressures to detect the tissue deformity by B-mode ultrasound. The fascial displacement was measured before and after compression (d). Subsequently, increments of 5mmHg pressure increases were used to generate a standard curve (0–80mmHg), thus mimicking rising compartment pressures. The intra-observer reliability was tested using 10 subsequent measurements. A correlation was determined between d and the simulated intacompartmental pressure (ICP) in the compartment. The Pearson correlation coefficient (r) was calculated. The reliability determined by the kappa value and a regression analysis was performed.


Tamer Kamal Robert Conway Ian Littlejohn David Ricketts

This paper describes an audit loop. We studied patients undergoing hip and knee surgery (arthroplasty and revision arthroplasty). All the patients were ‘complex elective’. I.e. they were either ASA grade 3 or 4, or had a body mass index in excess of 40. We collected data concerning postoperative admissions to HDU, ICU and PACU (planned and unplanned rates of admission, length of stay). We also noted mortality.

In the first part of the study (April 2005 to March 2006) we studied 298 patients. All patients were assessed independently by an anaesthetist on the day of surgery.

A multidisciplinary preoperative assessment clinic commenced in April 2006. After this date all patients were assessed preoperatively by a multidisciplinary anaesthetic lead team (anaesthetist, orthopaedic senior house officer, nurse practitioner). The need for an HDU or ICU bed was assessed and the bed was booked at part of the pre-operative plan.

In the second part of the study (May 2006 to April 2009) a further 1147 arthroplasty patients were studied. Data was again collected regarding HDU, ICU, PACU and mortality as noted above.

We found statistically significant (p=0.001) reductions in the admissions to PACU (22% down to 10%) and in mortality (6.1% down to 1.2%) after the introduction of the pre assessment clinic. There was also statistically significant (p=0.01) reduction in the HDU length of stay(2.1 days to 1.6 days), ITU unplanned admissions (1.3% to 0.4%) and the ITU length of stay in days (2.3 to 1.9 days).

We also estimated cost savings of nearly £50 000 in the second limb of the study. This is based on the average decrease in HDU and ICU length of stay.

We recommend the use of a multidisciplinary pre assessment clinic for complex orthopaedic surgery.


Christian Fontaine Guillaume Wavreille Marc Leroy Carlos Dos Remedios Christophe Chantelot

In rheumatoid arthritis (RA), non constrained or semi-constrained prostheses can be used. The authors used the Kudo III, IV or V or iBP prostheses 54 times from 1994 to 2003. After initial satisfactory results, they had to change one or both implants for several reasons: humeral stem fracture (5 cases), unipolar humeral loosening (1 case), ulnar loosening without laxity (8 cases), polyethylene wear (11 cases), due to progressive ulnar collateral ligament lengthening and progressive valgus deformity, without or with metallosis, due to contact between Cr-Co humeral component and titanium alloy ulnar component, chronic infection (1 case). When the local conditions were satisfactory (bone stock, ligament balance), the fractured or loosened component was changed. When the conditions were bad (poor bone stock, ligament misbalance, metallosis), both implants were removed; posterior humeral and/or medial or lateral ulnar window were used to removed the uncemented stems still osteointegrated. All the bipolar operations used the Coonrad-Morrey prosthesis, but the last case a Discovery prosthesis. The operative tricks are described, the management of the extensor apparatus is discussed, the clinical outcomes (especially the extensor apparatus function, most often weak) and the radiographic outcomes are presented.


Kodali Prasad Altaf Hussain

We hypothesised that an independent Notch Trial is essential on the same lines as other Component Trials-Femoral, Tibial and Patellar - in posterior stabilised total knee arthroplasty. Therefore we evolved Notch Trial to visually ascertain the adequacy of intercondylar resection and eliminate the possibility of femoral intercondylar fractures. We undertook a retrospective study to evaluate Notch Trial by the frequency of the need to remove osteophytes or file uneven surfaces in intercondylar resection by using the detachable box part of the trial femoral component, assess occurrence of distal femoral intercondylar fractures and demonstrate Notch Trial in posterior stabilised total knee replacement.

We studied 206 patients, 113 females and 93 males, who underwent consecutive primary posterior stabilised total knee replacements applying Notch Trial between 2000 and 2008 in a District General Hospital under our team. Outcome Measurements were 1) frequency of the need to remove osteophytes or file uneven surfaces in intercondylar resection and 2) occurrence of distal femoral intercondylar fractures intraoperatively or on postoperative radiographs. We had to remove the osteophytes and file the cut surfaces in 183 (88.88%) of patients after Notch Trial. We had no distal femoral intercondylar fractures intraoperatively or on postoperative radiographs.

Notch Trial allows the surgeon to directly visualise and ascertain the adequacy and precise fit of femoral notch cut with cam part of femoral component to ensure a press fit femoral component in condylar posterior cruciate substituting total knee replacement. Notch Trial prior to Femoral Component Trial effectively pre-empts intraoperative distal femoral intercondylar fractures. We recommend that Notch Trial should become part of the protocol for cruciate substituting total knee replacement and implants of all companies should have the option of a detachable box component for Notch Trial.


Vijay Kumar Bhavuk Garg Rajesh Malhotra

Introduction

We compared standard NexGen Cruciate substituting-flex prosthesis with gender-specific NexGen Cruciate substituting flex prosthesis in patients undergoing bilateral total knee arthroplasty with regard to Coverage of the bone by femoral component, Clinical outcome, Radiographic outcome, Survival and complication rates, with special emphasis on patellofemoral complications.

Material & Methods

30 female patients with osteo-arthritis of the knees with similar deformity and preoperative range of motion were randomized to have one knee replaced with a gender non-specific Nexgen Cruciate substituting (Zimmer) prosthesis and the other with Gender Cruciate substituting (Zimmer) prosthesis. Follow-up clinical evaluation was done at 6, and 12 months postoperatively and then at yearly interval using “Knee Society” Recommendations. Clinical assessment of the patellofemoral joint of the replaced knees was done with the help of “Hospital for Special Surgery” patellar scoring system. The overall patient satisfaction after surgery was evaluated with use of the British Orthopaedic Association patient satisfaction score.


Vijay Kumar Bhavuk Garg Rajesh Malhotra

Introduction

Tranexamic acid is an inhibitor of fibrinolysis that blocks the lysine-binding site of plasminogen to fibrin, and thereby decreases blood loss in patients undergoing surgery.

Aims and objectives

A prospective, randomized, double-blind study was done on 100 patients undergoing primary cemented Unilateral Total Knee Arthroplasty to determine the effect of tranexamic acid on intra- and postoperative blood losses and on the transfusions requirements.


Arne Borgwardt Lotte Borgwardt Soeren Ribel Madsen Lise Borgwardt Bo Zerahn Arne Borgwardt

In a randomized study of 60 patients allergic reactions are evaluated in three joint prosthesis groups, a resurfacing arthroplasty (ReCap), a non-cemented, large metal-on-metal head (Bimetric Magnum) and a non-cemented, alumina ceramic-on-ceramic bearing in a titanium shell (Bimetric C2a).

The inclusion criteria were osteoarthritis, ASA I–II, MRI-scan without caput necrosis, DXA-scan without osteoporosis. The exclusion criteria were short neck (<2cm.), large cysts (>1cm.), medical treatment affecting the bone metabolism, severe deformity of the femoral head, impaired kidney function and inability to co-operate.

Blood samples were drawn prior to and 6 weeks, 6 months, 1 year, and 3 years after surgery; two tubes from which plasma was prepared, and two tubes for serum. From the last included 20 patients in each group was also taken blood one and three years after surgery for an in vitro lymphocyte assay for scoring of possible hypersensitivity to prosthesis metals. The isolated lymphocytes were subjected to measurement of proliferation and expression of CD69 by flow cytometry and measurement of the Migration Inhibitory Factor (MIF) by ELISA. Plasma concentrations of the cytokines IL-1, IL-4, IL-6, IL-8, IL-12p70, IL-15, interferon-and osteoprotegerin were determined by multiplex-immunoassay. Serum concentrations of chromium and cobalt were determined by graphite furnace atomic absorption spectrometry.

The serum concentrations of chromium and cobalt were lowest in patients with the C2a implant and highest with Magnum, some of these differences were significant at 6 weeks, 6 months, and 1 year after surgery. No patient had a very high serum metal concentration. The values of the variables measured in the in vitro lymphocyte assay mainly changed in the expected direction depending on the concentration of the same metal in the serum sample drawn at the same time, but no significant correlation was seen. One patient had uncertain symptoms of metal hypersensitivity and relatively high serum metal concentrations 3 years after arthroplasty with a Magnum prosthesis and was assessed extraordinarily, and elicited the marginally highest MIF responses in the lymphocyte assay. A strong correlation was found between the plasma concentrations of most cytokines, but the cytokine concentrations were not correlated to contemporary metal concentrations.


Annette Ahrberg Nora Höde Christoph Josten

Objective

Ankle fractures are frequent and seem to be easy to handle in most cases. Of course, also these easy fractures can cause infections that must be carefully managed. What risk factors do we find? What options do we have in treating these complications? What are the consequences and what will the result for the patient be like, compared to non-infected cases?

In a retrospective study we included 82 patients treated with an osteosynthesis in ankle fractures (AO 44 B or C fractures). Average age was 52.4 years (range 20–84 years, median 51.0).

Results

In 9 (10.9%) patients there were septic complications. Concerning risk factors, we found 4 (44.4%) patients with nicotine abuse, 2 (22.2%) with additional alcohol abuse. Average stay in hospital was 39.6 days (range 9–95 days). In 4 (44.4%) cases local infection was treated with antibiotics and rest alone. 5 (55.5%) of the patients had additional operations due to infection, in average 5.4 per patient (range 1–10). Early implant removal was done in 3 (33.3%) cases, in average after 3 months. We found 2 (22.2%) infections due to Staphylococcus aureus, 1 (11.1%) due to MRSA and one infection with MRSA and Proteus mirabilis. In one case vacuum dressing had been applied for 44 days. In another case infection could only be healed with an intramedullary vancomycin augmented spacer and finally a screw arthodesis of the ankle, this was a patient with proven arteriosclerosis of the lower extremities. All other fractures finally showed bony healing in xrays. No plastic surgery (e.g. flaps) was needed to close a wound definitely.

In follow up (in average after 33 months, range 17–42), the average AOFAS of these patients was 76.5 (range 35–100, median 81.5), compared to an average AOFAS of 89.4 (range 35–100, median 98.0) of all patients.

No patient developed a septic syndrom, no ICU stay occurred because of the infection.


Jean-Yves Schoenahl Trevor Gaskill Peter Millett

Introduction

Osteoarthritis of the glenohumeral joint leads to global degeneration of the shoulder and often results in humeral or glenoid osteophytes. It is established that the axillary neurovascular bundle is in close proximity to the glenohumeral capsule. Similar to other compressive neuropathies, osteophytic impingement of the axillary nerve could result in axillary nerve symptoms. The purpose of this study was to compare the proximity of the axillary neurovascular bundle to the inferior humerus in shoulders to determine distance of the neurovascular bundle as the osteophyte (goat's beard) of glenohumeral osteoarthritis develops.

Methods

In this IRB approved study, preoperative MRI's of 98 shoulders (89 patients) with primary osteoarthritis (OA group) were compared to 91 shoulders (86 patients) with anterior instability (Control group). For MRI measurements (mm) two coronal-oblique T1 or proton density weighted images were selected for each patient located at 5 and 6 o'clock position of the glenoid in the parasagittal plane. Humeral head diameter to standardize the glenohumeral measurements, size of the spurs, and 6 measurements between osseus structures and axillary neurovascular bundle were obtained on each image using a calibrated measurement system (Stryker Office PACS Power Viewer). Level of significance was set at p>.05.


Anita Mohan Azal Jalgaonkar Derek Park Sebastian Dawson-Bowling William Aston Steve Cannon Tim Briggs

Sacral tumours are rare and can present difficult diagnostic and therapeutic challenges even at an early diagnosis. Surgical resection margins have a reported prognostic role in local recurrence and improved survival. Successful management is achieved within a specialist multidisciplinary service and involves combination chemotherapy, radiotherapy and surgery. We present our experience of patients with sacral tumours referred to our unit, who underwent total and subtotal sacrectomy procedures.

Materials and Methods

Between 1995 and 2010, we identified twenty-six patients who underwent a total or subtotal sacrectomy operation. Patients were referred from around the United Kingdom to our services. We reviewed all case notes, operative records, radiological investigations and histopathology, resection margins, post operative complications, functional outcomes and we recorded long-term survival outcomes. Patients who were discharged to local services for continued follow up or further oncological treatment were identified and information was obtained from their general practitioner or oncologist. We reviewed the literature available on total sacrectomy case series, functional outcomes and soft tissue reconstruction.

Results

We reviewed 26 patients, 16 male and 10 female, with a mean age at presentation of 53.4 years (range 11–80 years). Duration of symptoms ranged from 2 weeks to 6 years; lower back pain and sciatica were amongst the most common presenting features. Histological diagnoses included chordoma, Ewing's, malignant peripheral nerve sheath tumour, chondromyxoid fibroma, spindle cell sarcoma, synovial sarcoma, chondrosarcoma. A combined approach was used in two-thirds of patients and most of these patients had a soft tissue reconstruction with pedicled vertical rectus myocutaneous flap. Complications were categorised into major and minor and subdivided into wound, bladder and bowel symptoms. Wound complications and need for further intervention were more common amongst the patient group who did not have simultaneous soft tissue reconstruction at operation. All patients had a degree of bladder dysfunction in the early postoperative period. We present survivorship curves including recurrence and development of metastases.


Frederico Raposo António Sousa Luís Valente António Moura Gonçalves Miguel Loureiro Filipe Duarte Ricardo São Simão Joana Freitas Rui Pinto

INTRODUCTION

Patellar tendon (PT) autograft is an excellent choice repairing anterior cruciate ligament (ACL) ruptures. Published studies testing the biomechanical characteristics after plasty usually refer to grafts with 10mm wide. The thickness of PT and geometry of the patella have been overlooked.

The purpose of this study was to understand the geometry of PT and patella in our population, regarding their use in Bone - Patellar Tendon - Bone (BTB) technique, in order to evaluate their biomechanical efficiency and study their relationship with anthropometric parameters.

MATERIAL

100 individuals (50/50) who underwent knee MRI (3-Tesla). Ages between 18–65years.


Frederico Raposo Antonio Sousa Luis Valente Filipe Duarte Miguel Loureiro Eurico Monteiro Ricardo São Simão Antonio Moura Gonçalves Rui Pinto

Introduction

Interest in platelet-derived growth factors has been increasing as an adjunct in surgical techniques for tissue repair. Its use in ligament injuries repair has been studied mainly in animals. The authors intend to study growth factors influence in ACL repair using BTB graft.

Material

20 individuals underwent ACL rupture BTB arthroscopic repair, using Double Incision Mini-Invasive Technique. MRI (3-Tesla) images. GPSIII ® System to obtain Platelet-Rich Plasma (PRP) thrombin activated.


Kayode Oduwole Ben Cichy John Dillon Joan Wilson John O'beirne

Background

Controversy persists regarding preference between Herbert and Acutrak screw for internal fixation of scaphoid non-union. Acutrak screw has been shown to have better biomechanical compression properties than Herbert screw in the laboratory setting. The aim of this study was to assess the clinical, radiological and functional outcome of patients treated with the two different screw systems.

Methods

A retrospective review of the results of patients with scaphoid non-union treated by a single surgeon. Group 1 comprised of 61 patients treated with Herbert screw between July1996 and June2000 and Group 2 comprised of 71 patients treated with Acutrak screw between July 2000 and December 2005. Union rates were assessed radiologically and clinically. Functional outcome was measured by using modified Mayo wrist score.


Gideon Heinert Stefan Preiss Wolfgang Klauser Daniel Kendoff Patrick Sussmann

Introduction

Patellar tracking in total knee replacements has been extensively studied, but little is known about patellar tracking in isolated patellofemoral replacements. We compared patellar tracking and the position of the patellar groove in the natural knee, followed by implantation of the femoral component of a PFR (patella unresurfaced) and after implantation of the femoral & patellar component of the PFR.

Methods

Computer navigation was used to track the patella in eight whole lower extremities of four cadavers in the natural knee, in the same knee with the femoral component of the PFR (PFR-P) and with the femoral and patellar component of the PFR (PFR+P, patella resurfaced) (Depuy Sigma PFR). The form and position of the trochlea in the natural knee and the patellar groove of the femoral component was also analysed. Values are means+/−SD, two tailed Student's t-test for paired samples.


Karthik Karuppaiah Rajesh Nanda John Stothard Sivaraman Balasubramaniam

Introduction

The role of in-situ decompression in patients with severe ulnar nerve compression is still controversial. The authors present a prospective study on the results of in-situ decompression in this selected group of patients treated through a mini open incision (4cms) and complete decompression by appropriate patient positioning.

Material/Methods

Thirty patients (20 Male/10 Female) with severe degree of nerve compression, confirmed clinically by Dellon's classification and by abnormal Nerve Conduction Study, underwent simple in-situ decompression under general anaesthesia as a day-case procedure. Through a 4cms incision and by moving the elbow the nerve is fully visualised and decompressed.

Outcome was measured prospectively at three months and one year using Modified Bishop's score, grip strengths and two point discrimination (2PD).


Il Seok Park Kwang Am Jung Alvin Ong Seung Hyun Hwang Chang Hyun Nam Dong Won Lee

Background

Adequate rotation of femoral component in total knee arthroplasty(TKR) is mandatory for preventing numerous adverse sequelae. The transepicondylar axis has been a well-accepted reference for femoral component rotation in the measured resection technique. In this technique, measured resection is performed referenced off the tibial cut - perpendicular to the tibial mechanical axis with the knee in 90 ° of flexion. However, to the best of our knowledge, it is not known whether this technique apply well to a knee with tibia vara. This study evaluates the reliability of the transepicondylar axis as a rotational landmark in knees with tibia vara.

Methods

We selected 101 osteoarthritis knees in 84 symptomatic patients(mean age: 69.24 ± 5.68) with proximal tibia vara (Group A). Group A was compared with 150 osteoarthritic knees without tibia vara in 122 symptomatic patients (mean age: 69.51 ± 6.01) (Group B). The guide line for selection of all these knees were based on the degree of tibia vara angle (TVA) which was formed by line perpendicular to epiphysis and by anatomical axis of the tibia - all measured in radiographs of the entire lower limb. Magnetic resonance imaging (MRI) axial images with most prominent part of both femoral condyles were used for measurement of transepicondylar axis(TE), anteroposterior axis(AP) and posterior condylar axis(PC).


Riazuddin Mohammed Mohammed Farook Kevin Newman

We reviewed our results and complications of using a pre-bent 1.6mm Kirschner wire (K-wire) for extra-articular metacarpal fractures. The surgical procedure was indicated for angulation at the fracture site in a true lateral radiograph of at least 30 degrees and/or in the presence of a rotatory deformity.

A single K-wire is pre-bent in a lazy-S fashion with a sharp bend at approximately 5 millimetres and a longer smooth curve bent in the opposite direction. An initial entry point is made at the base of the metacarpal using a 2.5mm drill by hand. The K-wire is inserted blunt end first in an antegrade manner and the fracture reduced as the wire is passed across the fracture site. With the wire acting as three-point fixation, early mobilisation is commenced at the metacarpo-phalangeal joint in a Futuro hand splint.

The wire is usually removed with pliers post-operatively at four weeks in the fracture clinic.

We studied internal fixation of 18 little finger and 2 ring finger metacarpal fractures from November 2007 to August 2009. The average age of the cohort was 25 years with 3 women and 17 men. The predominant mechanism was a punch injury with 5 diaphyseal and 15 metacarpal neck fractures. The time to surgical intervention was a mean 13 days (range 4 to 28 days). All fractures proceeded to bony union. The wire was extracted at an average of 4.4 weeks (range three to six weeks). At an average follow up of 8 weeks, one fracture had to be revised for failed fixation and three superficial wound infections needed antibiotic treatment.

With this simple and minimally invasive technique performed as day-case surgery, all patients were able to start mobilisation immediately.

The general outcome was good hand function with few complications.


Reinhard Schuh Jochen Hofstaetter Roberto Bevoni Martin Krismer Hans-Joerg Trnka

Introduction

End-stage ankle osteoarthritis is a debilitating condition that results in functional limitations and a poor quality of life. Ankle arthrodesis (AAD) and total ankle replacement (TAR) are the major surgical treatment options for ankle arthritis. The purpose of the present study was to compare preoperative and postoperative participation in sports and recreational activities, assesses levels of habitual physical activity, functional outcome and satisfaction of patients who underwent eighter AAD or TAR.

Methods

41 patients (mean age: 60.1y) underwent eighter AAD (21) or TAR (20) by a single surgeon. At an average follow-up of 30 (AAD) and 39 (TAR) months respectively activity levels were determined with use of the University of California at Los Angeles (UCLA) activity scale. The American Orthopaedic Foot and Ankle Society (AOFAS) hindfoot score, patients's satisfaction and pre- and postoperative participation in sports were assessed as well.


Charles Bragdon Michael Doerner Mark Callanan David Zurakowski Young-Min Kwon Harry Rubash Henrik Malchau

Introduction

Acetabular cup positioning has been linked to dislocation and increased bearing surface wear. A previous study found correlations between patient and surgical factors and acetabular component position. The purpose of this study was to determine if acetabular cup positioning improves when surgeons receive feedback on their performance.

Methods

Post-op anteroposterior (AP) pelvis and cross-table lateral radiographs were previously obtained for 2061 patients who received a total hip arthroplasty (THA) or hip resurfacing from 2004–2008. The surgeries were performed by 7 surgeons. AP radiographs were measured using Hip Analysis Suite to calculate the cup inclination and version angles. Acceptable ranges were defined for abduction (30–45 °) and version (5–25 °). The same surgeons performed a THA or hip resurfacing on 385 patients from January 2009 through June 2010. Cup inclination and version angles for this set of surgeries were compared to surgeries from 2004–2008 to determine if cup inclination and version angles improved in response to previous acetabular cup positioning studies. Improvement in accuracy was assessed by the chi-square test.


Miao Wang Haisheng Li Kristian Hoey Ebbe Hansen Bent Niedermann Peter Helming Yu Wang Efe Aras Katrin Schattiger Cody Bunger

Study design: We conducted a prospective cohort study of 448 patients with a variety of spinal metastases.

Objective

To compare the predictive value of the Tokuhashi scoring system (T12) and its revised edition (T15) for life expectancy both in the entire study group as well as in the various primary tumor subgroups.

Summary of background data

In 1990 Tokuhashi and coworkers formulated a one point-addition-type prognostic scoring system with a total sum of 12 points for preoperative prediction of life expectancy as an adjunct in selecting appropriate treatment. Because the site of the primary tumor influences ultimate survival, the scoring system was revised in 2005 to a total sum of 15 points based on the origin of the primary tumor.


Pablo Corona E Gil J Roman C Amat E Guerra C Pigrau X Flores

Aims

Currently, the most common approach for the management of a chronic PJI is a Two-Stage Replacement; because of success rates exceeding 90% when using an antibiotic impregnated cement spacer. Reliable information regarding the etiologic microorganism and its sensitivities is essential to select the antimicrobial therapy that should be used locally in the bone cement spacer during the first stage surgery as well as to select the appropriate microbiological systemic agent. Diagnostic algorithms focus to the importance of joint aspiration cultures although in the modern literature, preoperative joint aspiration has a broad range of values of sensitivity and the proportion of “dry-aspirations” is not well assessed. This low sensitivity of aspiration fluid samples in chronic-PJI is partly attributable to the fact that the majority of the microorganisms in these infections grow in biofilms attached to the implant. We have developed this biopsy technique in an effort to improve the identification rates of the causative organism.

Materials and methods

A sample is harvested through a 4 mm bone trephine and the target is the bone-prosthesis gap. We have compared the results of preoperative PIB with the results of cultures from intra-operative tissue collected during the first stage surgery. In both cases a prolonged culture protocol (10 days) in enrichment media was used. On the basis of this relation, sensitivity, specificity, positive and negative predictive values and accuracy were calculated.


Markus Wurster Markus Wurster Robert Pätzold Oliver Gonschorek Volker Bühren

Introduction

Proximal tibial fractures frequently present in combination with other injuries which also have to be treated surgically. Recent publications do not consider isolated proximal tibial fracture (mono-injury) and combined injuries which include tibial fractures as two seperate medical entities. We therefore asessed the influence of additional injuries on treatment and outcome of the proximal tibial fractures.

Methods

We admitted 84 patients which were consecutively treated in our department from 01.01.2007 to 31.12.2009. Only C1 to C3 fractures (x-ray, ct-scan), according to AO classification with subsequent open reduction and internal plate osteosynthesis were included. Additionally we looked for additional injuries cause by the accident, numbers of operations and strategie of operative treatement, traumaspecific vs. postsurgical complications and inpatient days. At the follow-up investigations one year post surgery, Lysholm- and WOMAC-Score as well as Tegner-Activity-Index were used.


Emily Mounsey Edward Dawe Anil Golhar Michael Hockings

Introduction

High Tibial Osteotomy has become an increasingly popular management option for patients with painful medial compartment osteoarthritis. The Fujisawa method used to calculate the angle of correction is well-documented but there have been no studies to look at the reliability and accuracy of web-based systems to calculate this angle.

Patients and Methods

Patients undergoing valgus high tibial osteotomy between October 2004 and February 2010 who had full-length lower-limb views on the Picture Archiving and Communications System (PACS). The Fujisawa angle and length of osteotomy were calculated by the surgeon and two Orthopaedic registrars who had been appropriately trained.


Sven Hoppe Lars Frauchiger Jens Mainzer Peter Ballmer Rolf Hess Matthias Zumstein

Background

Navigation in total knee replacement is controversially discussed in the literature. In our previous study, femoral component positioning was more accurate with computed navigation than with conventional implantation techniques, however tibial positioning showed similar results. Moreover there were no differences between image-free and image-based navigation techniques. To what extent more accurate femoral positioning has an impact on the clinical mid-term follow up is not known.

Methods

At a mean follow-up interval of 5.3 years, seventy-one patients (84.5%) returned for a review and were examined clinically and radiographically, with use of a methodology identical to that used preop and at 2 years, using the subjective value, the Knee Society Score (KSS), and a.p. and true lateral standard radiographs respectively. Complications, re-operations, persisting pain and resulting range of motion were registered.


Farshad Adib Chandra Reddy Eric Guidi Robert Nirschl Derek Ochiai Andrew Wolff Clay Wellborn

Introduction

Superior Labral Anterior Posterior Tears are being treated surgically in increasing numbers. Stiffness is the most common complication. We reviewed 115 cases of SLAP repairs to try and identify preoperative risk factors if any for stiffness.

Methods

Retrospective cohort study of 115 patients who underwent SLAP repair. All patients failed attempts at conservative therapy including NSAIDS, Physical Therapy and cortisone injections.


Gaetano Caruso Vincenzo Lorusso Stefania Setti Ruggiero Cadossi Leo Massari

A multicenter retrospective analysis of patients treated for tibial fracture was conducted to develop a score that correlates with fracture healing time and, ultimately, to identify the risk gradient of delayed healing.

The clinical records of 93 patients treated for tibial fracture at three orthopaedic centers were evaluated. Patients were considered healed when full weight bearing was allowed and no further controls were scheduled. For the purpose of our analysis, we separated patients healed within or after 180 days.

Patient's risk factors known to be associated to delay healing, as well as fracture morphology and orthopaedic treatment were recorded in an electronic Case Report Form (e-CRF). Information available in the literature was used to weight the relative risk (RR) associated to each risk factor; values were combined to calculate a score to be correlated to the fracture healing time: L-ARRCO (Literature-Algoritmo Rischio Ritardo Consolidazione Ossea). Among all information collected in e-CRFs, we identified other risk factors, associated to delayed healing, that were used to calculate a new score: ARRCO. Univariate logistic analysis was used to determine a correlation between the score and healing time. Analysis by receiver operating characteristic (ROC) and calculation of the area under the curve (AUC) were used for sensitivity and specificity.

Complete information was available for 53 patients. The mean value of the L-ARRCO score among patients healed within 180 days was 5.78 ± 1.59 and 7.05 ± 2.46 among those healed afterwards, p=0.044. The mean value of the ARRCO score of patients healed within 180 days was 5.92 ± 1.78 and 9.03 ± 2.79 among those healed afterwards, p<0.0001. The ROC curve shows an AUC of 0.62±0.09 for L-ARRCO and an AUC of 0.82±0.07 for ARRCO, (p<0.0001).

We have shown that the ARRCO score value is significantly correlated to fracture healing time. The score may be used to identify fractures at risk of delayed healing, thus allowing surgeon's early intervention to stimulate osteogenesis.


Andrew Duckworth Nick Clement Stuart Aitken Paul Jenkins Charles Court-Brown Margaret Mcqueen

Introduction

This study investigates the epidemiology of proximal radial fractures and potential links to social deprivation.

Patients and Methods

From a prospective database we identified and analysed all patients who had sustained a fracture of the radial head or neck over a one year period. The degree of social deprivation was assessed using the Carstairs and Morris index. The relationship between demographic data, fracture characteristics and deprivation categories was determined using statistical analysis.


Florian Purghel Robert Badea Constantin Jemna Radu Ciuvic Alexandru Ivan

AIMS

Pure tibial plafond traumatic pathology (excluding trimalleolar fractures) is rare but troublesome, considering the surgical challenges and the long term disability perspective. Treatment involves a wide variety of implants and techniques, and the procedures choice and timing is highly dictated by the soft tissue damage. We designed this study to assess the status of our patients operated with internal, external or combined procedures.

METHODS

In a retrospective study, between July 2008 and July 2010 we reviewed 24 patients with available follow-up data. We reviewed the pre- and post-operative imaging available and the immediate follow-up data. A form is currently mailed to the patients to self-evaluate the general physical, mental and employment status, and also the affected limb, using general approved questionnaires. Data from this form is still in process.


Ioannis Pengas Anand Pillai Wade Gayed Aggelos Assiotis Michael Mcnicholas

The patella is a complex sesamoid bone within the quadriceps enhancing mechanical advantage of the extensor mechanism. Depending on activity, the patella magnifies either force or displacement; behaving as a lever, by redirecting quadriceps force it also acts as a pulley.

Aim

We describe and validate a device for obtaining consistent dynamic weight bearing views of the patellofemoral joint (PFJ).

Materials and Methods

Weight bearing (WB) axial views of 48 knees (24 patients) were performed using the device. The sulcus angle (SA), congruence angle (CA), lateral patellofemoral angle (LPFA), facet angle (FA) and patellofemoral displacement (PD) were measured. These were compared with similar measurements made on prone (PR) and axial (AX) radiographs of same knees.


Kiran Singisetti Ppj Raju Dj Langton Avf Nargol

INTRODUCTION

A detailed clinical examination and investigations are required to evaluate the cause of persisting groin pain following a metal on metal (MoM) hip replacement. Adverse reaction to metallic debris (ARMD) is an emerging problem with MoM hip replacements. It is an umbrella term encompassing metallosis, pseudo-tumors and aseptic lymphocytic vasculitis associated lesions (ALVAL). The role of imaging in the diagnosis of this complex problem is still unclear. A study was undertaken to evaluate the efficacy of ultrasound in diagnosis of ARMD following a MoM hip replacement.

METHODS

The study group included 35 patients with a clinical and histological diagnosis of ARMD, who had a preoperative ultrasound. All ultrasound procedures were performed on the anterior and lateral aspects of the painful hip with a high frequency probe of 9–13 MHz (Sonoline Antares – Siemens).


Fabian Wong Anna Przedlacka Hiang Boon Tan Paul Allen

Introduction

Anterior knee pain is a common presentation of patello-femoral dysfunction and patients with this disorder represent a significant proportion attending a specialist knee clinic. There is an on-going debate as to the cause and best treatment for such patients. Previous studies on patella-femoral morphology have suggested patella maltracking plays an important part in the aetiology but there had been no studies correlating maltracking with articular cartilage change.

Methods

We studied 147 consecutive patients (294 knees) aged between 10 and 63 presenting with anterior knee pain. All underwent MRI tracking scan of their knees as part of the routine investigations. We analysed the prevalence of maltracking with respect to gender, laterality and age groups, as well as patello-femoral articular cartilage changes.


Sebastien Lustig Frederic Laurent Ansissa Bouaziz Viviane Blanc-Pattin Jean-Philippe Rasigade Tristan Ferry Sylvestre Tigaud Philippe Neyret

Introduction

Rapid identification of bacteria from extemporaneous samples would greatly help management of prosthesis joint infection. The aim of the present retrospective study was to evaluate a new molecular assay (GeneXpert MRSA-SA SSTI (Cepheid)) for detecting Staphylococcus aureus (SA) and methicillin resistance directly from bone and joint samples in less an hour (58 minutes).

Material et method

Retrospective study using 91 frozen samples (76 patients) of joints (n=24), bone biopsies (n=42) and tissue biopsies (n=25):

SA positive samples: n=72 (methicillin susceptible SA (MSSA), n=63; methicillin resistant MRSA, n=9)

SA positive samples: n=19

The results were compared with routine results (culture in solid and liquid medium, identification and susceptibility test) from each participating lab.


Sebastien Lustig Emilie Allais Sandrine Boisset Tristan Ferry Sylvestre Tigaud Philippe Neyret Frederic Laurent

Introduction

Microbiological diagnosis of bone and joint infections (BJIs) currently relies on standard cultures which are time consuming and lack sensitivity. Various molecular approaches have been described and allowed improvement of BJI diagnosis. This study evaluated for the first time the performance of a DNA microarray-based assay (Prove-it™ Sepsis assay, PISA) for the rapid (<6 hours) detection and identification of 50 different species involved in BJI directly from clinical samples.

Material and methods

We retrospectively selected 130 bone and joint samples (67 synovial fluids and 63 bone biopsies) including 114 positive and 16 negative samples. The microbiological diagnosis had been previously established either by culture(C+, n=53) or by PCR16S and sequencing when culture was negative (C-/PCR+). The positive samples were selected to match the species targeted on the DNA microarray. DNA extraction was performed before proceeding to PISA amplification and hybridization on every selected sample.


Mohamed Sukeik Elizabeth Ashby Paul Sturch Karim Aboelmagd A Wilson Fares Haddad

Introduction

Wound surveillance has been reported to result in a significant fall in the incidence of wound sepsis in total knee arthroplasty (TKA). However, there is currently little guidance on the definition of surgical wound infection that is best to be used for surveillance. The purpose of this study was to assess the agreement between three common definitions of surgical wound infection as a performance indicator in TKA; (a) the CDC 1992 definition, (b) the NINSS modification of the CDC definition and (c) the ASEPSIS scoring method applied to the same series of surgical wounds.

Methods

A prospective study of 500 surgical wounds in patients who underwent knee arthroplasties between May 2002 and December 2004 from a single tertiary centre were assessed according to the different definitions of surgical wound infection.


Ian Starks Andrew Frost Peter Wall Justin Lim

The management of pelvic fractures remains a challenging problem for orthopaedic surgeons. The prompt recognition of unstable fracture patterns is important in reducing mortality and morbidity. It is perceived wisdom that a fracture of the transverse process of L5 is a predictor of pelvic fracture instability. There is a paucity of evidence in the literature to support this belief. The aim of our study was to determine if a fracture of the transverse process of L5 was a predictor of pelvic fracture instability.

The Hospital Trauma database was reviewed. Between 2006 and 2009, 65 pelvic fractures were identified. They were classified according to the Burgess and Young classification. There were 37 stable and 28 unstable fractures. 14 patients had an associated fracture of the transverse process of L5; 9 were associated with an unstable fracture pattern. The odds ratio was 3; the relative risk 1.7.

A fracture of the transverse process of L5 is associated with an increased risk of pelvic fracture instability. Its presence should alert the attending physicians to the possibility of an unstable injury.


Roderich Heikenfeld Rico Listringhaus Georgios Godolias

Aim

The purpose of this study was to evaluate the results after arthroscopic reconstruction of isolated SSP lesions. Does double row repair in smaller lesions lead to better results and a lower retear rate?

Method

80 patients with an isolated full thickness SSP tear were divided into 2 groups. Group 1 (27 men, 13 Frauen, average age 57 y.) was repaired using a single row technique with 2 anchors (Mitek Fastin) with arthroscopic Mason-Allen stiches. Group 2 was repaired using a double row technique using 1 medial anchor (Mitek Fastin) and 2 lateral anchors (Versalok). PreOP an ultrasound and MRI was obtained as well as standard x-rays (a.p., outlet-view, transaxial). Included to this study were only patients matching the following criteria: intraoperative cartilage lesions ≤ Outerbridge Grade2, fatty degeneration ≤ Goutallier Grade 2, ap extent of the tear < 2,5 cm. Prospective follow up after 6, 12 and 24 months using UCLA and Constant Score as well as MRI at last follow up.


David Roberts Nicholas Garlick

Introduction

Dislocation following total hip arthroplasty THA is a major short term complication not infrequently resulting in revision arthroplasty. Malposition of the acetabular component in THA results in a higher rate of dislocation as well as increased wear and osteolysis. The aim of this study was to assess the effect of mode of fixation on positioning of the acetabular component.

Patients, materials and methods

For all THAs performed at our hospital in 2008, angle of acetabular inclination was measured using PACS by two independent observers. Interobserver and intraobserver reliability were assessed (Pearson's correlation coefficient, r). We determined whether the number of acetabular components outside the target angle range (eg:45±5°) was significantly different between cemented and cementless THA (chi squared test). An enquiry was made to the National Joint Registry (NJR) in respect to incidence of revision for dislocation of THA using cemented and cementless acetabular components, 2004–2009.


Full Access
Pericles Papadopoulos Dimitrios Karataglis Achilleas Boutsiadis Stavros Charistos Lamprini Katranitsa Anastasios Christodoulou

Intra-articular shoulder pathology has been recognised in more detail following widespread use of shoulder arthroscopy. The purpose of this epidemiological study is to present the incidence and exact type of SLAP lesions in our operated population and to correlate them with the presence of other shoulder lesions.

Between 2004 and 2010 425 patients underwent shoulder arthroscopy in our department (311 for rotator cuff tears or subacromial impingement, 102 for shoulder instability, 12 for SLAP lesions). Eighty-two SLAP lesions (19.2% overall) were recognized during these procedures.

In 44 cases the lesion was SLAP type I (53.6%), in 10 type II (12.2%), in 1 type III (1.2%), in 1 type IV (1.2%), in 24 type V (29.26%) and finally in 2 type VI (2.43%). In more detail SLAP I lesions were associated in 8 patients with subacromial impingement syndrome, in 33 with RC tear and in 3 patients with anterior instability. Type II, III and IV were preoperatively diagnosed, while type V and VI lesions were found in patients with chronic anterior shoulder instability.

SLAP lesions are diagnosed more accurately during shoulder arthroscopy rather than with plain shoulder MRI scan. In our study population only 12 cases were accurately diagnosed with a pre-operative MRI scan, while the remaining 70 cases were missed. Additionally, there was significant correlation between rotator cuff problems and SLAP I lesions, while chronic shoulder instability was associated with SLAP V and VI (25.4% of patients with instability).

Shoulder arthroscopy not only has changed SLAP lesion diagnosis and treatment but also reveals the correlation of various SLAP lesion types with specific shoulder pathologies.


Heinz Winkler

Aims

Infections of bone usually require multiple surgery and prolonged periods of treatment. One reason for problems is found in the presence of stationary phase bacteria embedded in biofilms that show increased resistance against conventional antibiotic therapy (up to 1000x MIC). Biofilms adhere to surfaces of avital material making radical debridement a prerequisite for cure. Osseous defects are common in such conditions and need to be addressed. To avoid re-infection high local antbiotic concentrations are necessary. Allograft bone may be impregnated with high loads of antibiotics using a special incubation technique. The resulting antibiotic bone compound (ABC) provides high and long lasting concentrations at the site of infection and is likely to restore bone stock simultaneously. Based on this technology we have developed a new surgical technique.

Methods

42 patients (10–67yrs) with chronic osteitis were included into a prospective study using a standardized protocol. Infection was at the humerus (1x), femur (10x), tibia (29x) or femur+tibia (2x), respectively. Treatment consisted of removal of foreign material, radical sequestrectomy and soft-tissue debridement followed by pressurized lavage. Surfaces of sclerotic bone were trimmed down to vital areas. The remaining osseous defects were filled with ABC, using an impaction technique resulting in complete dead space management. The allograft was impregnated with vancomycin, in cases with mixed pathogens combinations with tobramycin were used. Internal fixation was performed the same time whenever applicable. Sites were drained and closed immediately; rehabilitation did not differ from uninfected procedures.


Preetham Kodumuri Hui-Ling Kerr Guido Geutjens

Septic Arthritis is an important life threatening condition affecting all age groups with a mortality of up to 11%. Our aim was to perform a study of the demographics, length of stay, complications and investigate if time delay of surgical treatment from the time of diagnosis has an impact on mortality and morbidity of the patients.

Methods

We performed a retrospective study of all the patients presented to our Hospital between 2005 and 2009 with septic arthritis who underwent arthroscopic lavage as definitive intervention. We excluded the patients involving minor joints. Data collection was performed from case notes, microbiology and haematology laboratory results. We divided the patients into three groups based on the time from diagnosis to arthroscopic lavage as T1 (less than 12 hours), T2 (12–24 hours) and T3 (more than 24 hours).

Our primary outcome measures were mortality and complications such as Intensive Care Admission. Secondary outcome measures included average length of stay in each group.

Results

A total of 57 patients were evaluated. The average age of the patients was 49.7 (10 months–94 years). 2 patients of T1 group died (5.4%) 3 patients of T1 group needed Intensive Care Unit (ICU) management (8.1%). There were no deaths or ICU admissions in the other groups. 40.3% of patients needed arthroscopic lavage more than once. The average length of stay of T1 was 19.8 days, T2–11.5 days and T3–27.5 days. Majority of the joints involved were knees (63.1%).23 patients (40.3%) had a preceding intervention performed in the same joint. Staphyloccus aureus was the most common organism isolated in 14 patients (26.3%).


B Oosthuizen J Myburgh D Tromp D Maré T Mole R Martin J Nel

The Versajet™ Hydrosurgery system (Smith & Nephew) offers a unique way of performing debridement using a high pressure fluid jet parallel to the surface to draw devitalized soft tissues into a cutting chamber for excision and evacuation. The aim of this study was to assess the outcome of the Versajet hydrosurgery system in the treatment of Gustilo and Anderson grade III A and III B open tibial fractures using a pilot scale prospective randomized controlled trial against conventional surgery. The primary variable was the total number of debridements until wound closure.

A total of 40 patients were recruited: 16 patients Versajet Plus™ (Smith & Nephew) hydrosurgery vs patients 24 standard surgical debridement. Baseline characteristics were well balanced with respect to the age, mechanism of injury, contamination, wound area, depth, and displacement of the bone. There was some imbalance between treatment groups where more (68.8%) Versajet patients had III A classification; vs. (37.5%) standard surgical debridement patients.

The number of debridement procedures before wound closure was for Versajet: 1 debridement procedure for 11 patients (69%), 2 for 3 patients (19%) and 3 for 2 patients (12.5%). For standard surgical patients: 1 debridement procedure for 1 patient (4.3%), 2 for 19 patients (83%) and 3 for 3 patients (13%). There was significant evidence (p<0.001) that Versajet patients required fewer debridement procedures than standard surgical debridement prior to wound closure (ratio Standard: Versajet=1.747). There was no evidence that the number of debridement procedures to achieve wound closure differed between the Gustilo and Anderson grade IIIA and grade IIIB classifications (p=0.692). The median time to wound closure was 3 days (95% CI 3 days, 5 days) for Versajet and 5 days (95% CI 4 days, 8 days) for standard surgically debrided wounds, but the difference was not statistically significant (p=0.275). There was no evidence (p=0.397) of a difference in the total number of surgical sessions (debridement or debridement with closure) required to close the wound (ratio Standard: Versajet=1.040; 95% CI (0.950, 1.137). There were no instances of post operative infection.

This pilot study has shown that on average only a single Versajet Plus hydrosurgery debridement is needed before IIIA or IIIB wounds are ready for closure and there is a trend (not significant) towards the possibility of earlier closure following the use of Versajet compared with standard surgery.


Gunnar Petursson Oystein Hovik Soren Bjerre Einar Amlie Ove Furnes Stephan Röhrl

Background

Tranexamic acid (TA) in total knee replacement surgery (TKR) has shown marked reduction in bleeding and blood transfusion. There are little data on TA in revision TKR. From February 2008 all patients having primary or revision TKR received TA 10mg/kg × 2. We whished to evaluate the effect and possible complications of TA.

Patients and Methods

49 patients had revision TKR from January to August 2010. 21 patients (group I) operated before the regular use of TA were compared to 28 patients (group II) receiving TA. The groups were compared according to bleeding, blood transfusion, postoperative complication and type of revision. Revision TKR was compared to 157 primary TKR (94 operated without TA (group III) and 63 who received TA (group IV).


Gunnar Petursson Anne Fenstad Leif Havelin Oystein Gothesen Stephan Röhrl Ove Furnes

Background

There are few studies of total knee replacements with cemented tibia and uncemented femur (hybrid). Previous studies have not shown any difference in revision rate between different fixation methods, but these studies had few hybrid prostheses. This study evaluates the results of hybrid knee replacements based on data from the Norwegian Arthroplasty Register (NAR).

Patients and Methods

Primary total knee replacements without patella resurfacing, reported to the NAR during the years 1999–2009, were evaluated. Hinged-, posterior stabilized- and tumor prostheses were excluded. LCS- and Profix prostheses with conforming plus bearing were included. With the risk for revision at any cause as the primary end-point, 2945 hybrid knee replacements (HKR) were evaluated against 20838 cemented knee replacements (CKR). Kaplan-Meier survival analysis and Cox regression analysis with adjustment for age, sex and preoperative diagnosis were used.


Alexander Kassianos Lisa Jeavons Robin Kincaid

Rivaroxaban, an oral direct factor Xa inhibitor was introduced for thromboprophylaxis at the Royal Cornwall Hospital for hip and knee arthroplasty surgery in October 2009.

Our aim was to investigate how safely Rivaroxaban could be implemented and how quickly its regular use was established.

We identified 140 patients from theatre logbooks who underwent elective total hip and knee joint replacements between October 2009 and March 2010. Patient notes, computer and DVT clinic records data were collected to determine the uptake of the new drug and the incidence of post-operative complications. We compared our chemical thromboprophylactic rates to those recorded at discharge in a 4-month period prior to our study in 2009. In addition we quantified the time needed before a newly introduced drug becomes established in clinical practice.

Patients were divided into two groups. Those who received Rivaroxaban were in group A (n=78, 55.7%) and those who received alternative or no chemical thromboprophylaxis constituted group B (n=62, 44.3%). All patients were prescribed TEDs stockings.

10.3% [8/78] of patients in group A suffered wound complications compared with 6.6% [4/62] of group B patients. Within group A we found that 41.1% (n=7) of the documented wound complications were wound ooze. DVTs occurred in both groups, 1 in group A and 2 in group B. 4 patients had postoperative haematemesis, 2 in each group.

Group A had 17 (22%) documented complications. A similar number (n=15, 24%) of patients in group B had recorded complications.

Our complication rates compared favourably to the RECORD 1–3 pooled study.

From January to April 2009, prior to introduction of Rivaroxaban, 51% of all elective hip and knee replacement surgery patients were receiving any chemical thromboprophylaxis on discharge. This increased to 83% following introduction of Rivaroxaban. During the first month of introduction of Rivaroxaban at our hospital, following NICE guideline, 28% of patients who qualified to receive the drug did. This improved to 95% by the time it had been in use by 3 months.

The data shows that there is no statistical significance in complications in thromboprophylaxis in elective total hip and knee replacement surgery between Group A and Group B (P-value 0.8941). This shows similar complication rates to the RECORD clinical study and concludes a safe introduction of the drug to our District General Hospital.

Patients in Group A had a reduced occurrence of thrombotic events, but an increase in cases of wound ooze when compared to group B.

Following the introduction of Rivaroxaban, it took 3 months for 95% of eligible patients for the drug to be NICE compliant. This demonstrated a 3 month run in time for the implementation of this new treatment regime in our hospital.


Tilman Calliess Christoph Becher Sven Ostermeier Henning Windhagen

Understanding the cause of failure of total knee arthroplasties (TKA) is essential in guiding clinical decision making and adjusting treatment concepts for revision surgery. The purpose of the study was to determine current mechanisms of failure of TKA and to describe changes and trends in revision surgery over the last 10 years.

A retrospective review was done on all patients who had revision total knee arthroplasty during a 10-year period (2000–2009) at one institution. The preoperative evaluation in conjunction with the intraoperative findings was used to determine causes of failure. All procedures were categorizes as Sharkey et al. described previously. The data was analyzed regarding the cause of failure and displaying the incidence and trends over the last 10 years.

1225 surgeries were done in the time period with a steady increase of procedures per year (34 procedures in 2000 to 196 in 2009). The most common cause of revision TKA was aseptic failure in 65% and septic failure in 31% of the reviewed cases. However, we could observe a steady proportional increase of the septic classified revisions over the time. Both categories could be subdivided to specific causes of failure including aseptic loosening (24%), anterior knee pain (20%), instability (6,4%), arthrofibrosis (4,9%), PE wear (3,6%), malpositioning/malrotation (2,7%) periprosthetic fracture (2,0%) and other (4,6%), or in early (12,9%), late (15,4%) or low-grade infection (3,3%), respectively. Complementary to the classification Sharkey et al. described in 2002 we identified new subcategories of failure: malrotation (since 2003), Low-Grade-Infection (since 2006), allergic failure/loosening (since 2006), Mid-Flexion-Instability (since 2007), soft tissue impingement (since 2009). The incidence of the classic aseptic loosening due to PE wear shows a clear decrease in the last 10 years whereas we could observe an increase of the new diagnosis of instability, malrotation or low-grade-infection as determined cause of failure.

The detailed analysis of the failure mechanism in total knee arthroplasty is important to understand the clinical problem and to adjust treatment strategies. We were able to complement present classifications and give a first overview on the incidence for specific causes of failure. Our data shows changes in the indication for surgery over the time and compared to the collective of Sharkey et al. from 1997–2000. This might be due to new diagnostic methods and better implant materials as well as to a generally increased awareness of the specific mechanism of TKA failure.


Myung Chul Lee Joon Kyu Lee Sang Cheol Seong Sahnghoon Lee Jak Jang Sang Min Lee Sang Ho Shim

Summary

Revision TKA using CCK prosthesis showed comparable outcome to PS prosthesis in clinical and radiological results.

Introduction

In revision total knee arthroplasty (TKA), the goal should be to obtain good motion, function and most importantly stability. The stability depends on remaining soft tissue and implant design. The more the ligaments retain function, the less the implant constraint is needed to achieve stability. With increased constraint, the transfer of joint reaction forces to implant-bone interface may lead to mechanical loosening of the implant. Constrained condylar knee (CCK) prosthesis provides more constraint compared with posterior stabilized (PS) prosthesis. The purpose of this study was to compare the clinical, radiological outcome and survivorship of CCK and PS prosthesis in revision TKA.


Ricardo Sousa Ana Claudia Santos Alexandre Pereira Marta Massada Antnio Oliveira

Background

Previous data from our institution show that more than half of all prosthetic joint infections are due to S. aureus. A significant proportion of these bacteria may have an endogenous source. Detecting and treating asymptomatic S. aureus nasal carriers preoperatively has been shown to reduce the risk of infection.

Material and Methods

This is an ongoing prospective study that started in March/2009 and involves primary total knee or hip arthroplasties candidates. So far preoperative nasal swab cultures were performed in 211(61%) out of 347 patients operated until April/2010. Carriers are identified and randomly chosen for preoperative treatment consisting of nasal mupirocin twice a day and daily cloro-hexidine baths in the 5 days that precede surgery. Antibiotic prophylaxis is cefazolin 24hours adding a single vancomycin dose in MRSA carriers.


Azad Hussain Amir Kamali Chenxi Li Roger Ashton

INTRODUCTION

Whilst there is a great deal of research on hip implants, few studies have looked at implant orientation and the subsequent effect upon the wear performance of a hip resurfacing. This study aimed to measure implantation angles through radiographic analysis and linear wear for retrieved acetabular cups in order to investigate possible causal links between wear and implant orientation.

MATERIALS & METHODS

Seventy Birmingham Hip Resurfacing (Smith & Nephew, UK) cups with known time in vivo were analysed. Linear wear of retrieved cups were assessed using a Talyrond 290 roundness machine. Deviations from the characteristic manufactured profile, was identified as a region of wear. Polar measurements across the wear region were taken to determine wear. The linear wear rate (LWR) of a component was defined as the linear wear (μm) divided by the duration of the implant life in vivo (years). Cups which showed the wear crossing over the edge of the cup were classified as edge loaded (EL). For all non-edge loaded (NEL) cups, the wear area was within the bearing surface. Cup orientation angles were conducted for 31 cups. This was determined by superimposing BHR models of appropriate size, generated by CAD ProEngineer Wildfire 4, onto anterior-posterior x-rays. Anatomical landmarks and specific features of the BHR were used as points of reference to determine cup version and inclination angles.


Bhavuk Garg Vijay Kumar Rajesh Malhotra Prakash Kotwal Aditya Soral

Introduction

Adequate exposure is a prerequisite for treatment of distal humeral fractures. In this study, we compared the clinico-radiological and functional outcome of TRAP approach with that of olecranon osteotomy for distal humerus fractures.

Material & Methods

27 patients with distal humerus fractures were randomized into 2 groups: Group 1 (n=14, TRAP approach), Group 2 (n=13, Olecranon osteotomy). All patients were operated with bi-columnar fixation. All patients were mobilized from day 2. Follow-up evaluation was done at 1, 3, 6 and 12 months.


Anestis Iossifidis Charalambos Petrou

Purpose

Our understanding of the spectrum of pathological lesions of the shoulder anterior capsular-labral complex in anterior instability continues to evolve. In a previous study using magnetic resonance arthrography we have showed three variants of the essential lesion of the anterior capsular-labral complex. This is the first large arthroscopic study to finely evaluate the nature and relative proportions of these three lesions in anterior instability.

Methods

We studied 122 patients, 101 male and 21 female patients with an average age of 28 (17 to 47 years old), undergoing primary arthroscopic stabilization for anterior instability between 2004 and 2008. The pathoanatomy of the anterior capsule-labral complex was documented. Based on our previous MRI arthrography experience we were able to categorize the lesions seen arthroscopically in three subgroups: the Bankart lesion, the Perthes lesion and the ALPSA (anterior periosteal sleeve avulsion).


Syed Nawaz George Bentley Tim Briggs Richard Carrington John Skinner Kieran Gallager Baljinder Dhinsa

Chondral injuries of the knee are extremely common and present a unique therapeutic challenge due to the poor intrinsic healing of articular cartilage. These injuries can lead to significant functional impairment. There are several treatment modalities for articular osteochondral defects, one of which is autologous chondrocyte implantation. Our study evaluates the mid to long term functional outcomes in a cohort of 828 patients who have undergone an autologous chondrocyte implantation procedure (either ACI or MACI), identifying retrospectively factors that may influence their outcome.

The influence of factors including age, sex, presence of osteoarthritis and size and site of lesion have been assessed individually and with multivariate analysis. All patients were assessed using the Bentley Functional Score, Visual Analogue Score and the Cincinnati Functional Score. Assessment were performed pre-operatively and of their status in 2010. The majority of patients had several interim scores performed at varying intervals.

The longest follow-up was 12 years (range 24 to 153 months) with a mean age of 34 years at time of procedure. The mean defect size was 486 mm2 (range 64 to 2075 mm2). The distribution of lesions was 51% Medial Femoral Condyle, 12.5% Lateral Femoral Condyle, 18% Patella (single facet), 5% Patella (Multifacet) and 6% Trochlea. 4% had cartilage transplant to multiple sites. 30% failed following this procedure at a mean time of 72 months. 52% patients stated a marked improvement in their functional outcomes within the first two years. 49% stated an excellent result following their procedure.

High failure rate was noted in those with previous cartilage regenerative procedures, transplants occurring on the patella, particularly if involving multifacets. Multiple site cartilage transplantation was also associated with a high failure rate.

Autologous chondrocyte implantation is an effective method of decreasing pain and increasing function, however patient selection plays clear role in the success of such procedure.


Abdul Khan Darren Ebreo Mohammad El Meligy Cathy Armstrong Viju Peter

Introduction

The advantages of metal on metal (MOM) hip replacement are decreased wear rate, preservation of bone stock, anatomical restoration and enhanced stability. Large amounts of metal wear particles and metal ions are released which may induce adverse reactions including local soft tissue toxicity, hypersensitivity reactions, bone loss and risk of carcinogenesis. Aseptic loosening can be the result of a peri prosthetic osteolysis generated as a result of a biological response to particulate wear debris.

Our aim in this study was to determine whether a steeply inclined acetabular component would give rise to a higher concentration of metal ions.

Patients and methods

Between April 2003 and June 2006, 22 patients had MOM hip replacement for osteoarthritis by a single Surgeon. There were 12 male and 10 female patients. The average age at the time of surgery was 56 years (Range: 44–69 years). We divided the 22 patients into 2 groups, one group (A) of 11 patients with the acetabular inclination angle more than 50 degrees and the other group (B) of 11 patients with the angle less than 50 degrees. The inclination of the acetabular cup was measured using a standard AP radiograph of the pelvis.

The patients had metal ion levels (blood chromium and serum cobalt) measured at an average follow up of 3.2 years (Range 2.4 to 5 years).


Masroor Naveed Masroor Naveed Andrew Porteous

We present 10–15 year follow-up of 33 patients who underwent Elmslie-Trillat osteotomy for severe patellar subluxation or dislocation. In the literature it has been reported that tibial tubercle osteotomy predisposes to subsequent patella-femoral arthritis, however it has never been documented if pre-existent knee chondral damage has any role in this development. In our group all patients had pre-op knee arthroscopy performed and extant of chondral damage was documented. We preformed an evaluation by long-term follow-up to determine weather pre-op chondral damage was the cause of subsequent osteoarthritis of patella-femoral joint. All patients were invited to attend outpatient clinic for clinical examination and knee radiographs and assessed by an independent research surgeon. Mean age at follow-up was 43 years and average follow-up was 10.5 years (range 10–15 years). 90% follow-up was achieved. Knee function was assessed by clinical scores (Lysholm knee score, American Knee Score, Oxford Knee score, Tegner and Insall knee scores) and three radiographs (AP, Lateral and Merchant views). Four patients had developed significant arthritis and underwent joint arthroplasty. Majority of patients reported good results with no further dislocation. However we noticed that extant of pre-op chondral damage was a significant factor in subsequent development of patella-femoral arthritis. We will present our data which is unique as no previous such long-term results have been reported for tibial tubercle transfers followed-up for more than 10 years and have pre-op arthroscopic documented chondral damage.


Veenesh Selvaratnam Vishwananth Shetty Tharjan Manickavasagar Vishal Sahni

Introduction

Nerve conduction studies are considered to be the investigation of choice for the diagnosis of Carpal Tunnel Syndrome. However they are expensive and can be painful.

We scored patients based on a ten point scoring system; four symptoms (Katz Hand Diagram – Classic and Probable pattern for tingling and numbness, nocturnal paresthesia, bilateral symptoms), four signs (weak thumb abduction test, Tinel sign, Phalen sign, Hypoalgesia in median nerve territory) and two risk factors (age more than 40 years and female sex). This was done in an effort to predict the severity of carpal tunnel syndrome and to correlate it with nerve conduction studies.

Method

A prospective study of 59 patients was performed between May 2009 and March 2010. For every patient in the study we completed a scoring system based on ten points and correlated it with the severity (normal, mild, moderate and severe) result from the nerve conduction studies.


Veenesh Selvaratnam James Fountain Nigel Donnachie Thomas Thomas Flintan Carroll

INTRODUCTION

Tranexamic Acid (TA) has been shown to decrease peri-operative bleeding in primary Total Knee Replacement (TKR) surgery. There are still concerns with regards to the increased risk of thromboembolic events with the use of TA. The aim of this study was to assess whether the use of pre-operative TA increased the incidence of Deep Vein Thrombosis (DVT) and Pulmonary Embolism (PE) in TKR.

METHODS

Patients who underwent primary TKR between August 2007 and August 2009 were identified from the databases of three surgeons within the lower limb arthroplasty unit. A retrospective case notes analysis was performed. DVT was diagnosed on Duplex Ultrasound Scan and PE on CT Pulmonary Angiogram. A positive result was a diagnosis of DVT or PE within 3 months of surgery.


Kristian Bjorgul Sven Andersen Knut Brevig Asle Bunes Einer Mogens Wiig Ola Ahlund Olav Reikeras

Cemented total hip arthroplasty yields reliable results in short to medium term studies, but aseptic loosening remains a problem in long-term follow up, especially in young and active patients. Aseptic loosening has been related to wear, and in order to minimize wear various alternatives to the traditional metal on polyethylene have been proposed. Both ceramic on polyethylene (COP) and metal on metal (MOM) have been shown to produce less wear than metal on polyethylene (MOP). In order to study the effect of the bearing, we have utilized identical stems and cups while comparing the different bearings.

Methods and material

396 hips were randomized to MOP, COP or MOM using a cemented triple tapered polished stem (MS-30; Sulzer Orthopedics) with a cemented polyethylene cup (Weber; Sulzer, Orthopedics) and a 28 millimeter head. For the MOP and COP articulations, a all-polyethylene cup was used with a Protasul™ metal head or a Sulox™ alumina head, whereas a polyethylene cup with metal insert was used for the MOM articulations (Weber Polyethylene Cup with Metasul™ Insert) with a Metasul™ metal head. Harris Hip Score (HHS) and radiological evaluation was performed after two, five and seven years. Ethical approval was obtained.

Results

HHS was available for 338 hips after seven years. The HHS in the MOP group (116 hips) was 93.7 (SD 9.0), 93.5 in the COP group (112 hips) (SD 8.8), and 91.0 (SD 13.4) in the MOM group (110 hips).

Radiographic evaluation was available for 335 hips. Radiolucencies around the stem larger than one millimeter were found in five of 115 MOP hips, seven of 111 COP hips and in seven of 110 MOM hips. Periacetabular radiolucencies identified as larger than one millimeter were found in none of the 116 MOP hips, five of the 112 COP hips and in 19 of the 110 MOM hips.

Ten revisions were performed. In the MOP group there were three revisions (infection, dislocation, pain); one in the COM group (infection), and six in the MOM group (three infections, two aseptic loosening and one septic loosening).


Alexandre Rochwerger Christophe Gaillard Ayman Tayeb Marie-Laure Louis Marianne Helix Georges Curvale

Introduction

The action of the radial head in the stability of the elbow is currently admitted. Its conservation is not always possible in complex fractures. The association with a posterolateral dislocation of the elbow leads to a higher risk of instability of the elbow joint and also at a longer term to degenerative changes. Some authors recommend the use of metallic radial head implant, acting as a spacer. The results seems encouraging but should the resection arthroplasty associated with the repair of the medial collateral ligament be abandoned?

Material and methods

In an amount of 35 consecutive patients who were taken in charge for an elbow dislocation 26 were included in this retrospective study, 13 of them had the association of a dislocation and a fracture of the radial head. In all 13 cases the radial head was considered as inadequate with a conservative treatment and was resected. The patients were assessed clinically according to the American Shoulder and Elbow Surgeons score (ASES) and the Mayo elbow performance index with a mean follow-up of 13 years (ranging from 5 to 15). The degenerative changes were assessed on plan × rays and an additional axial view according to the 4 stages described by Morrey.


George Grammatopoulos Andrew Judge Hemant Pandit Peter Mclardy-Smith Sion Glyn-Jones Koen Desmet David Murray Harinderjit Gill

INTRODUCTION

Although simulation studies have shown superior wear properties of metal-on-metal articulations, increased concern exists regarding the excess in-vivo wear of a small number of Metal-on-Metal-Hip-Resurfacing (MoMHRA) implants. Serum ion levels of Chromium (Cr) and Cobalt (Co) are surrogate markers of wear. Risk factors associated with increased wear include female gender, small components, dysplasia, cup orientation outside safe zone and femoral head downsize during surgery with an associated decrease in Head-Neck-Ratio (HNR). However, these factors are interlinked. This study aims to identify the factors that are most important for subsequent wear of MoMHRA, by performing a multivariate analysis.

METHODS

206 patients (124M: 82F) with unilateral MoMHRA were included in this study. The average follow up was 3.3 years. All patients had Cr/Co levels measured at follow up. Inclination and anteversion of each cup were measured using EBRA. Cups were analysed as being within or outside the previously defined optimum-zone. HNR measurements were made from pre-operative (HNRpre) and post-operative (HNRpost) radiographs. The immediate changes in HNR (downsize/upsize of femoral head) as a result of the operation were expressed as:

HNRprepost=HNRpost–HNRpre

Multivariate linear regression modelling was used to explore the association between measures of ions with the following predictor variables (gender, age, diagnosis, femoral component size, orientation of the acetabular component, head/neck ratio and position of femoral stem). Analyses were carried out separately for each outcome (Cr and Co). Classification and Regression Tree (CART) models were fitted as a complimentary approach to regression modelling.


George Grammatopoulos Hemant Pandit Katrien Backer Roger Gundle Peter Mclardy-Smith Koen Desmet David Murray Harinderjit Gill

INTRODUCTION

Femoral neck narrowing (NN) following Metal-on-Metal Hip Resurfacing Arthroplasty (MoMHRA) is a well-recognised clinical phenomenon. The incidence of resurfaced hips with NN > 10% is reported to be up to 27%. Its pathogenesis is thought to be multi-factorial secondary to stress shielding, impingement, osteolysis secondary to wear/ion particles and as a result of reduced vascularity and pressure effect on cancellous bone secondary to the presence of a soft-tissue mass around the resurfaced hip. Recognised risk factors for its development include: female gender and the presence of a pseudotumour. Serum Chromium (Cr) and Cobalt (Co) are recognised surrogate markers of in-vivo wear of MoMHRA. The aims of this study were to establish whether NN is associated with increased wear.

METHODS

A cohort of 214 patients with unilateral MoMHRA (139M: 75F) was included in this study. Primary osteoarthritis was the diagnosis leading to surgery for the majority of patients (208). The average age at surgery was 54.1 years old (13–73). Six different implants were used; BHR (116), Conserve plus (92), Recap (2), ASR (2), Adept (1) and Cormet (1). The average femoral component size was 49.2mm (range: 38–59). The average follow up was 4.3 years (range: 2–10). Patients were subdivided into 3 groups as per implant size. Small size component group had implants <45mm, average size group had components 45–51mm and large component size group had components >51mm.

All patients had Prosthesis-Junction-Ratio (PJR) measured from postoperative (PJRpost) and at latest follow up (PJRfollow) radiographs. Measurements were made using the method described by Lilikakis1.

Metal ion levels (Cr/Co) were measured at last follow-up for all patients. Cr level >5.1g/ml and Co levels >4.4 g/ml were considered high2 and patients with such levels formed the high ion group.


Vinay Singh Shazeena Hussain Sadaf Javed Ivor Singh Rohinton Mulla Yegappan Kalairajah

Background

Sterile Surgical Helmet System (SSHS) are used routinely in hip and knee arthroplasty in order to decrease the risk of infection. It protects surgeon from splash and also prevents contamination of surgical field from reverse splash by virtue of its perceived sterility. A prospective study was conducted to confirm if SSHS remain sterile throughout the procedure in Hip (THA) and Knee (TKA) Arthroplasty. We also evaluated if type of theatre had any effect on degree of contamination.

Material and Methods

Visor area of 40 SSHS was swabbed at half hourly interval until the end of the procedure. Two groups of 20 each were made on the basis of theatre used for performing surgery. Group 1 (Gp1) had surgery performed in laminar flow and Group 2 (Gp2) in non-laminar flow theatre. Swabs collected were processed to compare the time dependent contamination of the SSHS and identify the organisms responsible for contamination.


Oscar Ares Francisco Macule Dragos Popescu Josep Segur Sergi Sastre Juan Martinez-Pastor Luis Lozano Santiago Suso Montserrat Tio Ramona Garcia Montserrat Nunez

Orthopedic surgery is one of the most blood-consuming surgeries. Currently there has been a radical change in transfusion policies, developing a series of therapeutic measures essentially created to minimize the use of allogeneic blood.

On the one hand, the safety of our patients must be even more our main objective. On the other hand, our economic resources are more restricted and therefore we must evaluate our surgical techniques and proceedings in order to be safer and more cost-effective.

The aim of this study is to report our results of the blood lost, the percentage of blood loss, the necessity of transfussions and how many blood pakages are needed.

From a sample of 2400 total knee arthroplasties proceedings, we analyze some surgical proceedings such as lligament balance, patelar traking, artrotomy, ischemia, femoro-tibial axis and type of arthroplasty.

We also examine the total blood lost and the percentage of total blood loss after 4 hours, after 24hours and after 48 hour of the total knee arthoplasty surgery.

We made a statistical analysis with t-test or anova test when it was necesassary.

The outcome of our investigation show that the blood loss when the ischemia is less than 50 minutes is 1470 cc and 1603 cc when is more than 50 minuntes (p<0.05). If we use the medial arthrotomy, the total bleeding is 1563cc, but with subvastus arthrotomy is 1294cc (p<0.05). If we use a primary rotational total knee arthroplasty the bleeding is 953cc, but if we use a PS or PCR the bleeding is 874cc (p<0.05).

As a conclusion we should know that our patients have more blood loss when the ischemia is more than fifty minutes, the bleeding is higher when we make a medial arthrotomy and when we use a rotational knee primary arthroplasty.


Dai Miyasaka Tomoyuki Ito Ken Suda Norio Imai Naoto Endo Yoichiro Dohmae Izumi Minato

Several studies have reported the assessment of the femoral head coverage on plane radiograph and CT data in supine position, though young patients with the dysplastic hip often have symptoms during activities such as standing, walking, and running. On the other hand, some investigators have used a method of CT which allows standardization of the femoral head coverage against an anterior pelvic plane based on the anterior superior iliac spines and the pubic tubercle. We believe both the weight-bearing position and the standardized position to be more relevant for diagnosis and preoperative surgical assessment. So, we show the femoral head coverage in standardized position using 3D-CT method and in weight-bearing position using the plane radiograph and the three-dimensional lower extremity alignment assessment system before and after Curved periacetabular osteotomy (CPO). Especially the covered volume of the femoral head, a new concept, using the three-dimensional lower extremity alignment assessment system which differs from the affected area and is measured by the ratio of the covered area in the medial part of the line connecting the anterior point of the acetabulum with the posterior to the femoral head area in each axial slice, superior slices than the slice passing through the femoral head center, obtained from the reproduced 3D model of the pelvis and the femur in standing position allows us to integrate various measurements reported by past researchers.

We studied the consecutive 16 patients treated with CPO. In standardized position the sagittal sectional angles on the slice passing through the femoral head center using 3D-CT method gave us how the anterior, lateral, and posterior coverage was lack compared with normal subjects and whether the adequate transfer of the rotated fragment was performed after operation. The covered volume of the femoral head decides generally the deficiency or the adequateness. In standing position, though the pelvic tilt changes, the femoral head coverage on plane radiograph, representation by the CE angle, the VCA angle, AHI and ARO, was significantly improved, and the covered volume of the femoral head was significantly improved from 25.7% preoperatively to 51.1% postoperatively.

Our study showed the improvement of the femoral head coverage, including the covered volume of the femoral head as a new concept, after CPO in weight-bearing and standardized position. The morphological and functional assessment of the femoral head coverage on both pre- and post-CPO should be performed because we can obtain the objective information in standardized position and the femoral head coverage in standing position is closely connected with the pain.


Carolina Walker A Gulati M Bhatia

Introduction/Aim

Thromboembolism is a significant cause of patient morbidity and mortality, the risk of which increases in orthopaedic patients with lower limb immobilisation. It was therefore, our aim to identify a difference in symptomatic thromboembolism by treating acute Achilles tendon rupture patients with conventional non-weight bearing plaster versus functional weight bearing mobilisation.

Methodology

The notes of 91 consecutive patients with acute Achilles tendon rupture were reviewed. The patients demographics, treatment modality (non-weight bearing plaster versus weight bearing boot), and predisposing risk factors were analysed. From the 91 patients, 50 patients with acute Achilles tendon rupture were treated conservatively in a non-weight bearing immobilisation cast. From these 50 patients, 3 then underwent surgery and were therefore excluded from the results. 41 patients were treated with functional weight bearing mobilisation. Patients who did have a symptomatic thromboembolic event had an ultrasound scan to confirm a deep vein thrombosis of the lower limb, or a CT-scan to confirm pulmonary embolism.


George Grammatopoulos Geraint Thomas Hemant Pandit Sion Glyn-Jones Harinderjit Gill David Beard David Murray

INTRODUCTION

The introduction of hard-on-hard bearings and the consequences of increased wear due to edge-loading have renewed interest in the importance of acetabular component orientation for implant survival and functional outcome following hip arthroplasty. Some studies have shown increased dislocation risk when the cup is mal-oriented which has led to the identification of a safe-zone1. The aims of this prospective, multi-centered study of primary total hip arthroplasty (THA) were to: 1. Identify factors that influence cup orientation and 2. Describe the effect of cup orientation on clinical outcome.

METHODS

In a prospective study involving seven UK centers, patients undergoing primary THA between January 1999 and January 2002 were recruited. All patients underwent detailed assessment pre-operatively as well as post-op. Assessment included data on patient demographics, clinical outcome, complications and further surgery/revision. 681 primary THAs had adequate radiographs for inclusion. 590 hips received cemented cups. The primary functional outcome measure of the study was the change between pre-operative and at latest follow up OHS (OHS). Secondary outcome measures included dislocation rate and revision surgery. EBRA was used to determine acetabular inclination and version.

The influence of patient's gender, BMI, surgeon's grade and approach on cup orientation was examined. Four different zones tested as possibly ± (Lewinnek Zone, Callanan's described zone and zones ± 5 and ±10 about the study's mean inclination and anteversion) for a reduced dislocation risk and an optimal functional outcome.


Christoph Albers Simon Steppacher Reinhold Ganz Klaus Siebenrock Moritz Tannast

The Bernese Periacetabular Osteotomy (PAO) has become the established method for treating developmental dysplasia of the hip. In the 1990s, the surgical technique was modified to avoid postoperative cam impingement due to uncorrected head neck offset or pincer impingement due to acetabular retroversion after reorientation. The goal of the study was to compare the survivorship of two series of PAOs with and without the modifications of the surgical technique and to calculate predictive factors for a poor outcome.

A retrospective, comparative study of two consecutive series of PAOs with a minimum follow-up of 10 years was carried out. Series A included 75 PAOs performed between 1984 and 1987 and represent the first cases of PAO. Series B included 90 hips that underwent PAO between 1997 and 2000. In this series, emphasis was put on an optimal acetabular version next to the correction of the lateral coverage. Additionally, a concomitant arthrotomy was performed in every hip to check impingement-free range of motion after reorientation and in 50 hips (56%) an additional offset correction was performed. Survivorship analyses according to Kaplan and Meier were carried out and the endpoint was defined as conversion to a total hip arthroplasty, progression of osteoarthritis, or a Merle d'Aubign score 14. Predictive factors for poor outcome were calculated using the Cox-regression analysis.

The cumulative 10-year survivorship of Series A was significantly decreased (77%; 95%-confidence interval [CI] 72–82%) compared to Series B (86%; 95%-CI 82–89%, p=0.005). Hips with an aspherical head showed a significantly increased survivorship if a concomitant offset correction was performed intraoperatively (90% [95%-CI 86–94%] versus 77% [95%-CI 71–82%], p=0.003). Preoperative factors predicting poor outcome included a high age at surgery, a Merle d'Aubign score 14, a positive impingement test, a positive Trendelenburg sign, limp, an increased grade of osteoarthritis according to Tönnis, and (sub-) luxation of the femoral head (Severin > 3). In addition, predictive factors related to the three dimensional orientation of the acetabular fragment were identified. These included total, anterior, and posterior acetabular over-coverage or under-coverage, acetabular retroversion or excessive anteversion, a lateral center edge angle < 22 °, an acetabular index > 14 °, and no offset correction in aspherical femoral heads.

A good long term result after PAO mainly depends on optimal three-dimensional orientation of the acetabulum and impingement-free range of motion with correction of an aspherical head neck junction if necessary.