Advertisement for orthosearch.org.uk
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Volume 106-B, Issue SUPP_1 January 2024 The European Orthopaedic Research Society (EORS) 31st Annual Meeting, Porto, Portugal, 27–29 September 2023. Part 1 of 2.

C.H. Evans

Intra-articular injection is a common way to deliver biologics to joints, but their effectiveness is limited by rapid clearance from the joint space. This barrier can be overcome by genetically modifying cells within the joint such that they produce anti-arthritic gene products endogenously, thereby achieving sustained, therapeutic, intra-articular concentrations of the transgene products without re-dosing. A variety of non-viral and viral vectors have been subjected to preclinical testing to evaluate their suitability for delivering genes to joints. The first transfer of a gene to a human joint used an ex vivo protocol involving retrovirally transduced, autologous, synovial fibroblasts. Recent advances in vector technology allow in vivo delivery using adeno-associated virus (AAV). We have developed an AAV vector encoding the interleukin-1 receptor antagonist (AAV.IL-1Ra) for injection into joints with osteoarthritis (OA). It showed efficacy and safety in equine and rat models of OA, leading to a recently-completed, investigator-initiated, Phase I, dose-escalation clinical trial in 9 subjects with mid-stage OA of the knee (ClinicalTrials.gov Identifier: NCT02790723). Three cohorts of three subjects with mild to moderate OA in the index knee were injected intra-articularly under ultrasound guidance with a low (10e11 viral genomes) medium (10e12 viral genomes) or high (10e13 viral genomes) dose of AAV.IL-1Ra and followed for one year. The data confirm safety, with evidence of sustained intra-articular expression of IL-1Ra and a clinical response in certain subjects. Funding for a subsequent Phase Ib trial involving 50 subjects (ClinicalTrials.gov Identifier: NCT05835895), expected to start later this year, has been acquired. Progress in this area has stimulated commercial activity and there are now at least seven different companies developing gene therapies for OA and a number of clinical trials are in progress.

Acknowledgement: Clinical trial funded by US Department of Defense Clinical Trial Award W81XWH-16-1-0540.


G. Mariscal J. Burgos L. Antón-Rodrigálvarez E. Hevia C. Barrios

In healthy subjects, respiratory maximal volumes are highly dependent on the sagittal range of motion of the T7-T10 segment. In AIS, the abolition of T7-T10 dynamics related to the stiffness induced by the apex region in Lenke IA curves could harm ventilation during maximal breathing. The aim of this study was to analyze the dynamics of the thoracic spine during deep breathing in AIS patients and in healthy matched controls. This is a cross-sectional, case-control study. 20 AIS patients (18 girls, Cobb angle, 54.7±7.9°; Risser 1.35±1.2) and 15 healthy volunteers (11 girls) matched in age (12.5 versus 15.8 yr. mean age) were included. In AIS curves, the apex was located at T8 (14) and T9 (6). Conventional sagittal radiographs of the whole spine were performed at maximal inspiration and exhalation. The ROM of each spinal thoracic functional segment (T1-T7, T7-T10, T10-T12) and the global T1-T12 ROM were measured. In healthy subjects, the mean T1-T12 ROM during forced breathing was 16.7±3.8. AIS patients showed a T1-T12 ROM of 1.1±1.5 (p<0.05), indicating a sagittal stiffness of the thoracic spine. A wide T7-T10 ROM (15.3±3.0) was found in healthy controls (91.6% of the T1–T12 ROM). AIS patients showed only 0.4±1.4 ROM at T7-T10 (36.4% of the T1-T12 ROM) (p<0.001). There was a significant positive correlation between the magnitude of T7-T10 kyphosis in maximal exhalation and both FVC (% of predicted FVC) and FEV1. In conclusion, Lenke 1A AIS patients show a restriction of the thoracic spine motion with an almost complete abolition of T7-T10 ROM, a crucial segment for deep breathing. T7-T10 stiffness could explain the ventilatory limitations found in AIS patients.


R. Sohn T. Assar S. Braun M. Brenneis I. Kaufhold F. Zaucke G. Pongratz Z. Jenei-Lanzl

Osteoarthritis (OA) is the most common degenerative joint disorder. Its multifactorial etiology includes age, sex, joint overloading, genetic or nervous influences. In particular, the autonomic nervous system is increasingly gaining in importance. Its two branches, the sympathetic (SNS) and parasympathetic nervous system, are well-balanced under healthy conditions. OA patients seem to be prone to an autonomic imbalance and therefore, we analyzed their autonomic status.

More than 200 participants including patients with early and late stage knee OA (before and 1 year after knee replacement surgery) and healthy probands (age-matched) were analyzed. Heart rate variability was measured via electrocardiogram to assess long-term sympathetic (low-frequency=LF) and parasympathetic (high-frequency=HF, pRR50) activities or general variability (RMSSD, SDRR). Serum cortisol concentrations were measured by ELISA. Perceived chronic stress (PSQ) was assessed via questionnaire. Multivariant regression was performed for data analysis. LF/HF value of early OA was slightly increased compared to healthy controls but significantly higher compared to late OA patients before (p>0.05) and after TKR (p>0.01). HF in late OA patients before TKR was significantly decreased compared to patients after TKR (p>0.001) or healthy controls (p>0.05). Healthy probands exhibited the highest SDRR values, early OA patients had slightly lower levels and late OA patients before TKR displayed significantly reduced SDRR (p>0.001). The same differences were observed in pRR50 and RMSSD. Serum cortisol concentrations and PSQ scores increased in late OA patients before TKR. At the time point of TKR, women with beta blocker medication had significantly higher age (71 ± 9 years) than those without (63 ± 12 years)(p>0.01). An autonomic dysfunction with sympathetic dominance occurs in OA patients. The fact that beta blocker medication in women delayed the need of TKR indicates that SNS inhibition might counteract OA. Future therapeutic interventions for OA should consider a systemic approach with special regard on the ANS.


NW. Kucko K. Sage D. Delawi E. Hoebink DHR. Kempen J. Van Susante J. de Bruijn M. Kruyt

Pseudoarthrosis after spinal fusion is an important complication leading to revision spine surgeries. Iliac Crest Bone Graft is considered the gold standard, but with limited availability and associated co-morbidities, spine surgeons often utilize alternative bone grafts.

Determine the non-inferiority of a novel submicron-sized needle-shaped surface biphasic calcium phosphate (BCP<µm) as compared to autograft in instrumented posterolateral spinal fusion.

Adult patients indicated for instrumented posterolateral spinal fusion of one to six levels from T10-S2 were enrolled at five participating centers. After instrumentation and preparation of the bone bed, the randomized allocation side of the graft type was disclosed. One side was grafted with 10cc of autograft per level containing a minimum of 50% iliac crest bone. The other side was grafted with 10cc of BCP<µm granules standalone (without autograft or bone marrow aspirate). In total, 71 levels were treated. Prospective follow-up included adverse events, Oswestry Disability Index (ODI), and a fine-cut Computerized Tomography (CT) at one year. Fusion was systematically scored as fused or not fused per level per side by two spine surgeons blinded for the procedure.

The first fifty patients enrolled are included in this analysis (mean age: 57 years; 60% female and 40% male). The diagnoses included deformity (56%), structural instability (28%), and instability from decompression (20%). The fusion rate determined by CT for BCP<μm was 76.1%, which compared favorably to the autograft fusion rate of 43.7%. Statistical analysis through binomial modeling showed that the odds of fusion of BCP<μm was 2.54 times higher than that of autograft. 14% of patients experienced a procedure or possible device-related severe adverse event and there were four reoperations. Oswestry Disability Index (ODI) score decreased from a mean of 46.0 (±15.0) to a mean of 31.7 (±16.9), and 52.4% of patients improved with at least 15-point decrease.

This data, aiming to determine non-inferiority of standalone BCP<μm as compared to autograft for posterior spinal fusions, is promising. Ongoing studies to increase the power of the statistics with more patients are forthcoming.


L. Karaçoban M. Gizer B. Basak Fidan O. Kaplan M. Çelebier P. Korkusuz E. Turhan F. Korkusuz

Osteoarthritis (OA) is a disabling disease depriving the quality of life of patients. Mesenchymal stem cells (MSCs) are recently used to modify the inflammatory and degenerative cascade of the disease. Source of MSCs could change the progression and symptoms of OA due to their different metabolomic activities. We asked whether MSCs derived from the infrapatellar fat (IPF), synovium (Sy) and subcutaneous (SC) tissues will decrease inflammatory and degenerative markers of normal and OA chondrocytes and improve regeneration in culture. Tissues were obtained from three male patients undergoing arthroscopic knee surgery due to sports injuries after ethical board approval. TNFa concentration decreased in all MSC groups (Sy=156,6±79, SC=42,1±6 and IPF=35,5±3 pg/ml; p=0,036) on day 14 in culture. On day seven (Sy=87,4±43,7, SC=23±8,9 and IPF=14,7±3,3 pg/ml, p=0,043) and 14 (Sy=29,1±11,2, SC=28,3±18,5 and IPF=20,3±16,2 pg/ml, p=0,043), MMP3 concentration decreased in all groups. COMP concentration changes however were not significant. Plot scores of tissues for PC2-13,4% were significantly different. Based on the results of liquid chromatography-mass spectrometry (LC-MS) metabolomics coupled with recent data processing strategies, clinically relevant seven metabolites (L-fructose, a-tocotrienol, coproporphyrin, nicotinamide, bilirubin, tauro-deoxycholic acid and galactose-sphingosine) were found statistically different (p<0.05 and fold change>1.5) ratios in tissue samples. Focusing on these metabolites as potential therapeutics could enhance MSC therapies.

Acknowledgment: Hacettepe University, Scientific Research Projects Coordination Unit (#THD-2020-18692) and Turkish Society of Orthopedics and Traumatology (#TOTBID-89) funded this project. Feza Korkusuz MD is a member of the Turkish Academy of Sciences (TÜBA).


W. Liu M. Feng P. Xu

More and more evidences showed that cartilage harbored local progenitor cells that could differentiate toward osteoblast, chondrocyte, and adipocyte. However, our previous results showed that osteoarthritis derived chondroprogenitor cells (OA-CPC) exhibited strong osteogenic potential even in chondrogenic condition. How to promote their chondrogenic potential is the key for cartilage repair and regeneration in osteoarthritis. Recently, lipid availability was proved to determine skeletal progenitor fate. Therefore, we aim to determine whether lipid inhibition under 3D culture condition could enhance OA-CPC chondrogenesis. Moreover, glucose concentration was also evaluated for chondrogenic capacity. Although there are many researches showed that lower glucose promotes chondrogenesis, in our results, we found that OA-CPC in high concentration of glucose (4.5g/L) with lipid inhibitor (GW1100) showed strongest chondrogenic potential, which could form largest cell pellet with strong proteoglycan staining, COL II expression and no COL I expression. Besides, COL2A1 was increased and COL10A1 was decreased significantly by GW1100 under high glucose condition in 2D culture. Interestingly, although the expression level of MMP13 was not changed by GW1100 at RNA and protein level, less MMP13 protein secreted out of cell nuclear. In summary, we estimated that higher glucose and lower lipid supplies benefit OA-CPC chondrogenesis and cartilage repair.


A. Macmillan H. Muhammad R. Al Hosni M. Alkhayref A. Hotchen E. Robertson-Waters E. Strangmark B. Gompels J.H. Wang S. McDonnell W. Khan M. Clatworthy M. Birch A. McCaskie

In relation to regenerative therapies in osteoarthritis and cartilage repair, mesenchymal stromal cells (MSCs) have immunomodulatory functions and influence macrophage behaviour. Macrophages exist as a spectrum of pro-(M1) and anti-(M2) inflammatory phenotypic subsets. In the context of cartilage repair, we investigated MSC-macrophage crosstalk, including specifically the priming of cartilage cells by macrophages to achieve a regenerative rather than fibrotic outcome. Human monocytes were isolated from blood cones and differentiated towards M1 and M2 macrophages. Monocytes (Mo), M1 and M2 macrophages were cultured directly and indirectly (trans-well system) with human bone marrow derived MSCs. MSCs were added during M1 polarisation and separately to already induced M1 cells. Outcomes (M1/M2 markers and ligands/receptors) were evaluated using RT-qPCR and flow cytometry. Influence on chondrogenesis was assessed by applying M1 and M2 macrophage conditioned media (CM) sequentially to cartilage derived cells (recapitulating an acute injury environment). RT-qPCR was used to evaluate chondrogenic/fibrogenic gene transcription. The ratio of M2 markers (CD206 or CD163) to M1 markers (CD38) increased when MSCs were added to Mo/M1 macrophages, regardless of culture system used (direct or indirect). Pro-inflammatory markers (including TNFβ) decreased. CXCR2 expression by both M1 macrophages and MSCs decreased when MSCs were added to differentiated M1 macrophages in transwell. When adding initially M1 CM (for 12 hours) followed by M2 CM (for 12 hours) sequentially to chondrocytes, there was a significant increase of Aggrecan and Collagen type 2 gene expression and decrease in fibroblastic cell surface markers (PDPN/CD90). Mo/M1 macrophages cultured with MSCs, directly or indirectly, are shifted towards a more M2 phenotype. Indirect culture suggests this effect can occur via soluble signaling mediators. Sequential exposure of M1CM followed by M2CM to chondrocytes resulted in increased chondrogenic and reduced fibrotic gene expression, suggesting that an acute pro-inflammatory stimulus may prime chondrocytes before repair.


M. Habash D. Cawley A. Devitt

Intra-Discal Vacuum Phenomenon (IDVP) represents an intradiscal nitrogen gas accumulation where a cavity opens in a supine position, lowering intra-discal pressure and generating a bubble. IDVP has been observed in up to 20% of elderly patients and reported in almost 50% of chronic LBP patients. With a highly accurate detection on CT, its significance lacks clarity and consideration within normative data. IDVP occurs with patterns of lumbar and/or lumbopelvic morphology and associated diagnoses. Over-60s population based sample of 2020 unrelated CT abdomen scans without acute spinal presentations, with sagittal reconstructions, inclusive of T12 to femoral heads, were analyzed for IDVP and pelvic incidence (PI). Subjects with diagnostic morphological associations of the lumbar spine, including previous fracture, autofusion, transitional vertebra and listhesis, were selected out and analyzed separately. Subjects were then equally grouped into low, medium and high PI. Prevalence of lumbar spine IDVP is 41.3%. 125 cases were excluded. 1603 subjects yielded 663 IDVP. This was increased in severity towards the lumbosacral junction (L1L2 9.4%, L2L3 10.9%, L3L4 13.7%, L4L5 19.9%, L5S1 28.5%) and those with low PI, while distribution was more even with high PI. 292 had positive diagnostic associations, which were more likely to occur at the level of isthmic spondylolisthesis, adjacent to a previous fracture or suprajacent to lumbosacral transitional vertebra (p<0.05).

This study has identified normative values for prevalence and severity of IDVP in a normal aging population. Morphological patterns that influence the pattern of IVDP such as pelvic incidence and diagnostic associations provide novel insights to the function of the aging spine.


G. Vadalà G.F. Papalia F. Russo L. Ambrosio D. Franco P. Brigato R. Papalia V. Denaro

The use of intraoperative navigation and robotic surgery for minimally invasive lumbar fusion has been increasing over the past decade. The aim of this study is to evaluate postoperative clinical outcomes, intraoperative parameters, and accuracy of pedicle screw insertion guided by intraoperative navigation in patients undergoing lumbar interbody fusion for spondylolisthesis. Patients who underwent posterior lumbar fusion interbody using intraoperative 3D navigation since December 2021 were included. Visual Analogue Scale (VAS), Oswestry Disability Index (ODI), and Short Form Health Survey-36 (SF-36) were assessed preoperatively and postoperatively at 1, 3, and 6 months. Screw placement accuracy, measured by Gertzbein and Robbins classification, and facet joint infringement, measured by Yson classification, were assessed by intraoperative Cone Beam CT scans performed at the end of instrumentation. Finally, operation time, intraoperative blood loss, hospital stay, and screw insertion time were evaluated. This study involved 50 patients with a mean age of 63.7 years. VAS decreased from 65.8±23 to 20±22 (p<.01). ODI decreased from 35.4%±15 to 11.8%±14 (p<.01). An increase of SF-36 from 51.5±14 to 76±13 (p<.01) was demonstrated. The accuracy of “perfect” and “clinically acceptable” pedicle screw fixation was 89.5% and 98.4%, respectively. Regarding facet violation, 96.8% of the screws were at grade 0. Finally, the average screw insertion time was 4.3±2 min, hospital stay was 4.2±0.8 days, operation time was 205±53 min, and blood loss was 169±107 ml. Finally, a statistically significant correlation of operation time with hospital stay, blood loss and placement time per screw was found. We demonstrated excellent results for accuracy of pedicle screw fixation and violation of facet joints. VAS, ODI and SF-36 showed statistically significant improvements from the control at one month after surgery.

Navigation with intraoperative 3D images represents an effective system to improve operative performance in the surgical treatment of spondylolisthesis.


X. Tian C. Vater D. B. Raina L. Findeisen L.-M. Matuszewski M. Tägil L. Lidgren K.-D. Schaser A.C. Disch S. Zwingenberger

Although bone morphogenetic protein 2 (BMP-2) has been FDA-approved for spinal fusion for decades, its disadvantages of promoting osteoclast-based bone resorption and suboptimal carrier (absorbable collagen sponge) leading to premature release of the protein limit its clinical applications. Our recent study showed an excellent effect on bone regeneration when BMP-2 and zoledronic acid (ZA) were co-delivered based on a calcium sulphate/hydroxyapatite (CaS/HA) scaffold in a rat critical-size femoral defect model. Therefore, the aim of this study was to evaluate whether local application of BMP-2 and ZA released from a CaS/HA scaffold is favorable for spinal fusion. We hypothesized that CaS/HA mediated controlled co-delivery of rhBMP-2 and ZA could show an improved effect in spinal fusion over BMP-2 alone. 120, 8-week-old male Wistar rats (protocol no. 25-5131/474/38) were randomly divided into six groups in this study (CaS/HA, CaS/HA + BMP-2, CaS/HA + systemic ZA, CaS/HA + local ZA, CaS/HA + BMP-2 + systemic ZA, CaS/HA + BMP-2 + local ZA). A posterolateral spinal fusion at L4 to L5 was performed bilaterally by implanting group-dependent scaffolds. At 3 weeks and 6 weeks, 10 animals per group were euthanized for µCT, histological staining, or mechanical testing. µCT and histological results showed that the CaS/HA + BMP-2 + local ZA group significantly promoted bone regeneration than other treated groups. Biomechanical testing showed breaking force in CaS/HA + BMP + local ZA group was significantly higher than other groups at 6 weeks. In conclusion, the CaS/HA-based biomaterial functionalized with bioactive molecules rhBMP-2 and ZA enhanced bone formation and concomitant spinal fusion outcome

Acknowledgements: Many thanks to Ulrike Heide, Anna-Maria Placht (assistance with surgeries) as well as Suzanne Manthey & Annett Wenke (histology).


G. Petrucci G. F. Papalia F. Russo L. Ambrosio R. Papalia G. Vadalà V. Denaro

Chronic low back pain (CLBP) is the most common cause of disability worldwide, and lumbar spine fusion (LSF) is often chosen to treat pain caused by advanced degenerative disease when clinical treatment failed certain cases, the post-surgical outcomes are not what was expected. Several studies highlight how important are. In psychological variables during the postoperative spine surgery period. The aim of this study is to assess the role of preoperative depression on postoperative clinical outcomes. We included patients who underwent LSF since December 2021. Preoperative depression was assessed administering Beck Depression Inventory questionnaire (BDI). And pain and disability were evaluated at 1, 3, and 6 months, administering respectively Visual Analogic Scale (VAS) and Oswestry Disability Index (ODI). As statistical analysis Mann-Whitney test was performed. We included 46 patients, 20 female (43,5%) and 26 male (56,5%) with an average age of 64,2. The population was divided in two groups, fixing the BDI cut-off point at 10. Patients with BDI < 10 points (N=28) had normal mental health status, instead patients with BDI > 10 points (N=16) had depressive disorders. At 3 months patients with healthy mental status reported statistically significant reduction of pain (U = 372,5, p = .006) and improvement of disability but without statistical significancy (U = 318, p = 0,137). At 6 months patients without psychological disease reported statistically significant reduction of pain (U = 342, p = 0,039) and disability (U = 372,5, p = 0,006).

This study demonstrates the correlation between pre-existing depressive state and poorer clinical outcomes after spine surgery. These results are consistent with the literature. Therefore, during the surgical decision making it is crucial to take psychological variables into account in order to predict the results after surgery and inform patients on the potential influence of mental status.


J.M. Fernández-Costa A. Tejedera-Villafranca M.J. Ugarte-Orozco A. Cortés-Reséndiz J. Ramón-Azcón

Duchenne muscular dystrophy (DMD) is a prevalent childhood neuromuscular disease characterized by progressive skeletal and cardiac muscle degeneration due to dystrophin protein deficiency. Despite ongoing drug development efforts, no cure exists, with limited success in preclinical studies. To expedite DMD drug development, we introduce an innovative organ-on-a-chip (OOC) platform. This microfluidic device sustains up to six 3D patient-derived skeletal muscle tissues, enabling real-time evaluation of anti-DMD treatments. Our in vitro model recreates myotube integrity loss, a hallmark of DMD, by encapsulating myogenic precursors in a fibrin-composite matrix using a PDMS casting mold. Continuous contractile regimes mimic sarcolemmal instability, monitored through tissue contractibility and Creatine Kinase (CK) levels—an established marker of muscle damage. We further enhance our platform with a nanoplasmonic CK biosensor, enabling rapid, label-free, and real-time sarcolemmal damage assessment. Combining these elements, our work demonstrates the potential of OOCs in accelerating drug development for DMD and similar neuromuscular disorders.


S.P.B. Teixeira A. Pardo S.M. Bakht M. Gomez-Florit R.L. Reis M.E. Gomes R.M.A. Domingues

Tendon diseases are prevalent health concerns for which current therapies present limited success, in part due to the intrinsically low regenerative ability of tendons. Therefore, tissue engineering presents a potential to improve this outcome. Here, we hypothesize that a concurrent control over both biophysical and biochemical stimuli will boost the tenogenic commitment of stem cells, thus promoting regeneration. To achieve this, we combine molecularly imprinted nanoparticles (MINPs), which act as artificial amplifiers for endogenous growth factor (GF) activity, with bioinspired anisotropic hydrogels2 to manufacture 3D tenogenic constructs. MINPs were solid phase-imprinted using a TGF-β3 epitope as template and their affinity for the target was assessed by SPR and dot blot. Magnetically-responsive microfibers were produced by cryosectioning electrospun meshes containing iron oxide nanoparticles. The constructs were prepared by encapsulating adipose tissue-derived stem cells (ASCs), microfibers, and MINPs within gelatin hydrogels, while aligning the microfibers with an external magnetostatic field during gelation. This allows an effective modulation of hydrogel fibrillar topography, mimicking the native tissue's anisotropic architecture. Cell responses were analyzed by multiplex immunoassay, quantitative polymerase chain reaction, and immunocytochemistry. MINPs showed an affinity for the template comparable to monoclonal antibodies. Encapsulated ASCs acquired an elongated shape and predominant orientation along the alignment direction. Cellular studies revealed that combining MINPs with aligned microfibers increased TGF-β signaling via non-canonical Akt/ERK pathways and upregulated tendon-associated gene expression, contrasting with randomly oriented gels. Immunostaining of tendon-related proteins presented analogous outcomes, corroborating our hypothesis.

Our results thus demonstrate that microstructural cues and biological signals synergistically direct stem cell fate commitment, suggesting that this strategy holds potential for improving tendon healing and might be adaptable for other biological tissues. The proposed concept highlights the GF-sequestering ability of MINPs which allows a cost-effective alternative to recombinant GF supplementation, potentially decreasing the translational costs of tissue engineering strategies.

Acknowledgements: The authors acknowledge the funding from the European Union's Horizon 2020 under grant No. 772817; from FCT/MCTES for scholarships PD/BD/143039/2018 & COVID/BD/153025/2022 (S.P.B.T.), and PD/BD/129403/2017 (S.M.B.), co-financed by POCH and NORTE 2020, under the Portugal 2020 partnership agreement through the European Social Fund, for contract 2020.03410.CEECIND (R.M.A.D.) and project 2022.05526.PTDC; and from Xunta de Galicia for grant ED481B2019/025 (A.P.).


H. Helmholz B. Mavila Chathoth N. Angrisani J. Reifenrath R. Willumeit-Römer

Osteoarthritis (OA) is an inflammatory disease affecting the complete synovial joint including the cartilage layer and the subchondral bone plate. Due to the multifactorial causes and the not yet completely resolved molecular mechanisms, it lacks a gold standard treatment to mitigate OA. Hence, biomaterials capable of delaying or preventing OA are a promising alternative or supplement to antiphlogistic and surgical interventions. Magnesium (Mg) and its alloys are among the promising biomaterials with osteoinductive effects. This work investigated the impact of Mg micro cylinders (length ≈of 1.0 mm and width of 0.5 mm) in vitro, in favoring joint regeneration together with preventing OA progression. Therefore, a mesenchymal stem cell line (SCP-1) was applied in order to assess the compatibility of the degradable material. Furthermore, an in vitro OA model utilizing SCP-1 cells based on the supplementation of the cytokines; IL-1β, TNF-α was established and disclosed the capability of Mg microparticles in differentiating SCP-1 cells into chondrogenic and osteogenic lineages proven through extracellular matrix staining and gene marker analysis. A concentration above 10 mM revealed a reduction in the cell viability by 50 %. An increase in the expression of collagens especially and proteoglycans (COL2A1, Aggrecan) as extracellular matrix proteins as well as an increase in osteogenic marker (ALP, BMP2) favoring the mineralization process were observed. The inflammatory condition reduced the viability and productivity of the applied stem cell line. However, the application of Mg microparticles induced a cell recovery and reduction of inflammation marker such as MMP1 and IL6. The cytocompatible and the ability of Mg microparticles in supporting bone and cartilage repair mechanisms in vitro even under inflammatory conditions make biodegradable Mg microparticles a suitable implant material to treat OA therapy.

Acknowledgements: This project OAMag was funded by the German Research Foundation (project number 404534760). The author thank Dr. Björn Wiese (hereon) for the production of Mg based material and Prof. Böcker (MUM Musculoskeletal University Center Munich) for the provision of SCP-1 cell line.


B. Costa P. Alves D. Fonseca F. Campos Ana C. Monteiro R. Pereira F. Costa P. Gomes Guillermo Martínez-de-Tejada C. Monteiro M.C.L. Martins

Orthopedic Device-Related Infections (ODRIs) are a major medical challenge, particularly due to the involvement of biofilm-encased and multidrug-resistant bacteria. Current treatments, based on antibiotic administration, have proven to be ineffective. Consequently, there is a need for antibiotic-free alternatives. Antimicrobial peptides (AMPs) are a promising solution due to their broad-spectrum of activity, high efficacy at very low concentrations, and low propensity to induce resistance. We aim to develop a new AMP-based chitosan nanogel to be injected during orthopedic device implantation to prevent ODRIs. Chitosan was functionalized with norbornenes (NorChit) through the reaction with carbic anhydride and then, a cysteine-modified AMP, Dhvar5, a peptide with potent antibacterial activity, even against methicillin-resistant Staphylococcus aureus (MRSA), was covalently conjugated to NorChit (NorChit- Dhvar5), through a thiol-norbornene photoclick chemistry (UV= 365 nm). For NorChit-Dhvar5 nanogels production, the NorChit-Dhvar5 solution (0.15% w/v) and Milli-Q water were injected separately into microfluidic system. The nanogels were characterized regarding size, concentration, and shape, using Transmission Electron Microscopy (TEM), Nanoparticle Tracking Analysis (NTA) and Dynamic light scattering (DLS). The nanogels antibacterial properties were assessed in Phosphate Buffer (PBS) for 6 h, against four relevant microorganisms (Pseudomonas aeruginosa, S. aureus and MRSA, and in Muller- Hinton Broth (MHB), 50% (v/v) in PBS, supplemented with human plasma (1% (v/v)), for 6 and 24 h against MRSA. The obtained NorChit-Dhvar5 nanogels, presented a round-shaped and ∼100 nm. NorChit- Dhvar5 nanogels in a concentration of 1010 nanogels/mL in PBS were capable of reducing the initial inoculum of P. aeruginosa by 99%, S. aureus by 99%, and MRSA by 90%. These results were corroborated by a 99% MRSA reduction, after 24 h in medium. Furthermore, NorChit-Dhvar5 nanogels do not demonstrate signs of cytotoxicity against MC3T3-E1 cells (a pre-osteoblast cell line) after 14 days, having high potential to prevent antibiotic-resistant infection in the context of ODRIs.


M.V. Lipreri A. Pasquarelli D. Scelfo N. Baldini S. Avnet

Osteoporosis is a progressive, chronic disease of bone metabolism, characterized by decreased bone mass and mineral density, predisposing individuals to an increased risk of fractures. The use of animal models, which is the gold standard for the screening of anti-osteoporosis drugs, raises numerous ethical concerns and is highly debated because the composition and structure of animal bones is very different from human bones. In addition, there is currently a poor translation of pre-clinical efficacy in animal models to human trials, meaning that there is a need for an alternative method of screening and evaluating new therapeutics for metabolic bone disorders, in vitro.

The aim of this project is to develop a 3D Bone-On-A-Chip that summarizes the spatial orientation and mutual influences of the key cellular components of bone tissue, in a citrate and hydroxyapatite-enriched 3D matrix, acting as a 3D model of osteoporosis. To this purpose, a polydimethylsiloxane microfluidic device was developed by CAD modelling, stereolithography and replica molding. The device is composed by two layers: (i) a bottom layer for a 3D culture of osteocytes embedded in an osteomimetic collagen-enriched matrigel matrix with citrate-doped hydroxyapatite nanocrystals, and (ii) a upper layer for a 2D perfused co-culture of osteoblasts and osteoclasts seeded on a microporous PET membrane.

Cell vitality was evaluated via live/dead assay. Bone deposition and bone resorption was analysed respectively with ALP, Alizarin RED and TRACP staining. Osteocytes dendrite expression was evaluated via immunofluorescence. Subsequently, the model was validated as drug screening platform inducing osteocytes apoptosis and administrating standard anti-osteoporotic drugs.

This device has the potential to substitute or minimize animal models in pre-clinical studies of osteoporosis, contributing to pave the way for a more precise and punctual personalized treatment.


B. Wildemann

The Global Burden of Disease Study 2019 showed a 33.4% increase in fractures and a 65.3% increase in Years lived with disability (YLD) since 1990. Although the overall rate of fracture related infection (FRI) is low, it increases to 30% in complex fractures. In addition, the implantation of foreign materials, such as fracture stabilizing implants, decreases the number of bacteria needed to cause an infection. Then, when infections do occur, they are difficult to treat and often require multiple surgeries to heal. The bacteria can persist in the canaliculi of the bony tissue, in cells, in a biofilm on material or necrotic bone or in abscess communities. In the last decades, different approaches have been pursued to modify biomaterials as well as implant surface and to develop antimicrobial surfaces or local drug release strategies. This talk will give an introduction to the problem of bony and implant associated infections and presents the development and preclinical (as well as clinical) studies of two approaches for local drug delivery.


D. Ghezzi M. Sartori M. Boi M. Montesissa E. Sassoni M. Fini N. Baldini M. Cappelletti G. Graziani

Prosthetic joint infections represent complications connected to the implantation of biomedical devices, they have high incidence, interfere with osseointegration, and lead to a high societal burden. The microbial biofilm, which is a complex structure of microbial cells firmly attached to a surface, is one of the main issues causing infections. Biofilm- forming bacteria are acquiring more and more resistances to common clinical treatments due to the abuse of antibiotics administration. Therefore, there is increasing need to develop alternative methods exerting antibacterial activities against multidrug-resistant biofilm-forming bacteria. In this context, metal-based coatings with antimicrobial activities have been investigated and are currently used in the clinical practice. However, traditional coatings exhibit some drawbacks related to the insufficient adhesion to the substrate, scarce uniformity and scarce control over the toxic metal release reducing their efficacy. Here, we propose the use of antimicrobial silver-based nanostructured thin films to discourage bacterial infections. Coatings are obtained by Ionized Jet Deposition, a plasma-assisted technique that permits to manufacture films of submicrometric thickness having a nanostructured surface texture, allow tuning silver release, and avoid delamination. To mitigate interference with osseointegration, here silver composites with bone apatite and hydroxyapatite were explored. The antibacterial efficacy of silver films was tested in vitro against gram- positive and gram-negative species to determine the optimal coatings characteristics by assessing reduction of bacterial viability, adhesion to substrate, and biofilm formation. Efficacy was tested in an in vivo rabbit model, using a multidrug-resistant strain of Staphylococcus aureus showing significant reduction of the bacterial load on the silver prosthesis both when coated with the metal only (>99% reduction) and when in combination with bone apatite (>86% reduction). These studies indicate that IJD films are highly tunable and can be a promising route to overcome the main challenges in orthopedic prostheses.


R.W. Li J. Zheng P.N. Smith X. Chen

Device-associated bacterial infections are a major and costly clinical challenge. This project aimed to develop a smart new biomaterial for implants that helps to protect against infection and inflammation, promote bone growth, and is biodegradable. Gallium (Ga) doped strontium-phosphate was coated on pure Magnesium (Mg) through a chemical conversion process. Mg was distributed in a graduated manner throughout the strontium-phosphate coating GaSrPO4, with a compact structure and a Ga-rich surface. We tested this sample for its biocompatibility, effects on bone remodeling and antibacterial activities including Staphylococcus aureus, S. epidermidis and E. coli - key strains causing infection and early failure of the surgical implantations in orthopaedics and trauma.

Ga was distributed in a gradient way throughout the entire strontium-phosphate coating with a compact structure and a gallium-rich surface. The GaSrPO4 coating protected the underlying Mg from substantial degradation in minimal essential media at physiological conditions over 9 days. The liberated Ga ions from the coatings upon Mg specimens inhibited the growth of bacterial tested. The Ga dopants showed minimal interferences with the SrPO4 based coating, which boosted osteoblasts and undermined osteoclasts in in vitro co-cultures model.

The results evidenced this new material may be further translated to preclinical trial in large animal model and towards clinical trial.

Acknowledgements: Authors are grateful to the financial support from the Australian Research Council through the Linkage Scheme (ARC LP150100343). The authors acknowledge the facilities, and the scientific and technical assistance of the RMIT University and John Curtin School of Medical Research, Australian National University.


O. Omar J. Kraus-Schmitz B. Barenius K. Eriksson A. Stålman

Septic arthritis following anterior cruciate ligament reconstruction (ACLR) is a rare and serious complication. Previous studies have shown that septic arthritis is associated with inferior outcome of ACLR. Despite that, there is no standardized treatment protocol, and the course of the disease has mainly been studied within single institutions with a small number of patients.

The aim of the present study is to describe the course of septic arthritis following ACLR in a large nationwide cohort. The hypothesis was that the clinical presentation of septic arthritis following ACLR varies according to the infectious agent.

The present cohort represents patients with septic arthritis identified in a previous study that analyzed compensation claims reported to the Swedish national insurance company (Löf) in 2005–2014 (1). The diagnosis was confirmed by medical experts at Löf after review of medical records. We conducted a comprehensive analysis of the medical records as well as data available from the Swedish National Knee Ligament Registry (SNKLR) for the study group.

The study involved 158 patients who received compensation due to developing septic arhtirits. 94 (59.9%) patients were infected with Coagulase negative staphylococci (CoNS), and 25 patients by Staphyolococcus Aureus (S.Aureus) (15.9%). There was a significant difference between the groups regarding Maximum CRP (p<0.001), and duration between ACLR and first washout operation (p<0.005). S.aureus group had the higest maximum CRP (281) and the shortest duration between ACLR and first washout operation (12 days).

The Clinical presentation of septic arthritis following ACLR can vary according to the agent causing the infection, and low virulent agents are responsible for the majority of the infections. Clinicians need to be aware of these differences and consider them when making diagnosis or treatment decisions.


H. Harting A. Polyak N. Angrisani T. Herrmann N. Ehlert J. Meißner M. Willmann S. Al-Bazaz T.L. Ross J.P. Bankstahl J. Reifenrath

In orthopedic surgery, implant infections are a serious issue and difficult to treat. The aim of this study was to use superparamagnetic nanoporous silica nanoparticles (MNPSNP) as candidates for directed drug delivery. Currently, short blood circulation half-life due to interactions with the host's immune system hinder nanoparticles in general from being clinically used. PEGylation is an approach to reduce these interactions and to enhance blood circulation time. The effect of PEGylation of the used 68Ga-labelled MNPSNP on the distribution and implant accumulation was examined by PET/CT imaging and gamma counting in an implant mouse model.

Female Balb/c mice (n=24) received a magnetic implant subcutaneously on the left and a titanium implant on the right hind leg. On day one, 12 of these mice received an additional clodronate®-injection for macrophage depletion. On the second postoperative day, mice were anaesthetized and MNPSNP (native or PEGylated) injected intravenously, followed by a dynamic PET-scan over 60 minutes, a CT- and a static PET-scan at 120 min. As control, 12 mice received only 68Ga-MNPSNP (native or PEGylated). Gamma counting of inner organs, urine, blood and implant area was performed as further final analysis. Although PEGylation of the nanoparticles already resulted in lower liver uptakes, both variants of 68Ga-labeled MNPSNP accumulated in liver and spleen. Combination of PEGylation with clodronate®-injection led to a highly significant effect whereas clodronate®-injection alone could not reveal significant differences. In gamma counting, a significantly higher %I.D./g was found for the tissue surrounding the magnetic implants compared to the titanium control, although in a low range. PEGylation and/or clodronate®-injection revealed no significant differences regarding nanoparticle accumulation at the implantation site. PEGylation increases circulation time, but MNPSNP accumulation at the implant site was still insufficient for treatment of infections. Additional efforts have to further increase circulation time and local accumulation.

Acknowledgements: This work is funded by the German Research Foundation (DFG, project number 280642759).


E. García-Rey F. Pérez-Barragans L. Saldaña

Total hip arthroplasty (THA) outcome in patients with osteonecrosis of the femoral head ONFH) are excellent, however, there is controversy when compared with those in patients with osteoarthritis (OA). Reduced mineralization capacity of osteoblasts of the proximal femur in patients with ONFH could affect implant fixation.

We asked if THA fixation in patients with ONFH is worse than in those with OA.

We carried out a prospective comparative case (OA)-control (ONFH) study of patients undergoing THA at our hospital between 2017 and 2019. The minimum follow-up was 2 years. Inclusion criteria were patients with uncemented THA, younger than 70 years old, a Dorr femoral type C and idiopathic ONFH. We compared the clinical (Merlé D'Aubigné-Postel score) and radiological results related with implant positioning and fixation. Engh criteria and subsidence were assessed at the immediate postoperative, 12 weeks, 6 months, 12 months and yearly. Osteoblastic activity was determined by mineralization assay on primary cultures of osteoblasts isolated from trabecular bone samples collected from the intertrochanteric area obtained during surgery.

Group 1 (ONFH) included 18 patients and group 2 (OA), 22. Average age was 55.9 years old in group 1 and 61.3 in group 2. (p=0.08). There were no differences related with sex, Dorr femoral type or femoral filling. The mean clinical outcome score was 17.1 in group 1 and 16.5 in group 2 (p=0.03). There were no cases of dislocation, infection, or revision surgery in this series. There were 5 cases (28%) of femoral stem subsidence greater than 3mm within 6 first months in group 1 and 1 case (4.5%) in group 2 (p=0.05).

Although there were no significant differences related to clinical results, bone fixation was slower, and a greater subsidence was observed in patients with ONFH. Greater femoral stem subsidence was associated with a lower capacity for mineral nodule formation in cultured osteoblasts. The surgical technique could influence THA outcome in patients with reduced mineralization capacity of osteoblasts.


C. Ciatti F. Quattrini C. Asti P. Maniscalco

Previous scientific studies have highlighted how coupling is an important element affecting total hip arthroplasty's survival.

This study aims to evaluate whether metal-on-metal (MOM) coupling could be a statistically significant risk factor.

The data from the regional joint registry (Registro dell'Impiantologia Protesica Ortopedica, RIPO) was used for analysis. The data collection accuracy of this registry was 97.2% in 2017.

We retrospective evaluate all MOM total hip arthroplasties (THAs) implanted in our department between January 01st 2000 and December 31st 2011. We used a control group composed by all other prosthesis implanted in our Department in the same time lapse.

We registered 660 MOM THAs. Mean age of patients was 66.9 years. 603 patients have a >36mm head, while 78 a <36 mm one. Neck modularity was present in half of patients. 676 implants were cementless. We registered 69 revisions, especially due to aseptic mobilization (16 THAs), implant breakage (9 THAs) and periprosthetic fracture (6 THAs).

The MOM THAs overall Kaplan-Meier survival rate was 87.2 at 15 years, and the difference between MOM THAs and other implants two curves is statistically significant (p<0.05). Male sex is a significant risk factors. Further evaluations are in progress to establish the presence of any additional risk factors. We think weight and/or BMI may be included in this category.

Our study confirms the data currently present in the literature regarding a lower survival of metal-on-metal hip prostheses.

The male sex is a statistically significant risk factor (p<0.05), while age, head size and modularity of the prosthetic neck are not statistically significant (p>0.05).

Any new finds will be presented at the congress venue.


J. Burgos G. Mariscal L.M. Antón-Rodrigálvarez I. Sanpera E. Hevia V. García C. Barrios

The aim of this study was to report the restauration of the normal vertebral morphology and the absence of curve progression after removal the instrumentation in AIS patients that underwent posterior correction of the deformity by common all screws construct whitout fusion. A series of 36 AIS immature patients (Risser 3 or less) were include in the study. Instrumentation was removed once the maturity stage was complete (Risser 5). Curve correction was assessed at pre and postoperative, before instrumentation removal, just post removal, and more than two years after instrumentation removal. Epiphyseal vertebral growth modulation was assessed by a coronal wedging ratio (WR) at the apical level of the main curve (MC). The mean preoperative coronal Cobb was corrected from 53.7°±7.5 to 5.5º±7.5º (89.7%) at the immediate postop. After implants removal (31.0±5.8 months) the MC was 13.1º. T5–T12 kyphosis showed a significant improvement from 19.0º before curve correction to 27.1º after implants removal (p<0.05). Before surgery, WR was 0.71±0.06, and after removal WR was 0.98±0.08 (p<0.001). At the end of follow-up, the mean sagittal range of motion (ROM) of the T12-S1 segment was 51.2±21.0º. SRS-22 scores improved from 3.31±0.25 preoperatively to 3.68±0.25 at final assessment (p<0.001). In conclusion, fusionless posterior approach using a common all pedicle screws construct correct satisfactory scoliotic main curves and permits removal of the instrumentation once the bone maturity is reached. The final correction was highly satisfactory and an acceptable ROM of the previously lower instrumented segments was observed.


L. Saldaña N. Vilaboa E. García-Rey

The pathophysiological basis of alterations in trabecular bone of patients with osteonecrosis of the femoral head (ONFH) remains unclear. ONFH has classically been considered a vascular disease with secondary changes in the subchondral bone. However, there is increasing evidence suggesting that ONFH could be a bone disease, since alterations in the functionality of bone tissue distant from the necrotic lesion have been observed. We comparatively studied the transcriptomic profile of trabecular bone obtained from the intertrochanteric region of patients with ONFH without an obvious aetiological factor, and patients with osteoarthritis (OA) undergoing total hip replacement in our Institution. To explore the biological processes that could be affected by ONFH, we compared the transcriptomic profile of trabecular bone from the intertrochanteric region and the femoral head of patients affected by this condition. Differential gene expression was studied using an Affymetrix microarray platform. Transcriptome analysis showed a differential signature in trabecular bone from the intertrochanteric region between patients with ONFH and those with OA. The gene ontology analyses of the genes overexpressed in bone tissue of patients with ONFH revealed a range of enriched biological processes related to cell adhesion and migration and angiogenesis. In contrast, most downregulated transcripts were involved in cell division. Trabecular bone in the intertrochanteric region and in the femoral head also exhibited a differential expression profile. Among the genes differentially expressed, we highlighted those related with cytokine production and immune response. This study identified a set of differently expressed genes in trabecular bone of patients with idiopathic ONFH, which might underlie the pathophysiology of this condition.

Acknowledgements: This work was supported by grants PI18/00643 and PI22/00939 from ISCIII-FEDER, Ministerio de Ciencia, Innovación y Universidades (MICINN)-AES.


A. Jacob M. Heumann I. Zderic P. Varga J. Caspar S. Lauterborn D. Haschtmann T. Fekete B. Gueorguiev M. Loibl

Stand-alone anterior lumbar interbody fusion (ALIF) provides the opportunity to avoid supplemental posterior fixation. This may reduce morbidity and complication rate, which is of special interest in patients with reduced bone mineral density (BMD). This study aims to assess immediate biomechanical stability and radiographic outcome of a stand-alone ALIF device with integrated screws in specimens of low BMD.

Eight human cadaveric spines (L4-sacrum) were instrumented with SynFix-LR™ (DePuy Synthes) at L5/S1. Quantitative computed tomography was used to measure BMD of L5 in AMIRA. Threshold values proposed by the American Society of Radiology 80 and 120 mg CaHa/mL were used to differentiate between Osteoporosis, Osteopenia, and normal BMD. Segmental lordosis, anterior and posterior disc height were analysed on pre- and postoperative radiographs (Fig 1). Specimens were tested intact and following instrumentation using a flexibility protocol consisting of three loading cycles to ±7.5 Nm in flexion-extension, lateral bending, and axial rotation. The ranges of motion (ROM) of the index level were assessed using an optoelectronic system.

BMD ranged 58–181mg CaHA/mL. Comparison of pre- and postoperative radiographs revealed significant increase of L5/S1 segmental lordosis (mean 14.6°, SD 5.1, p < 0.001) and anterior disc height (mean 5.8mm, SD 1.8, p < 0.001), but not posterior disc height. ROM of 6 specimens was reduced compared to the intact state. Two specimens showed destructive failure in extension. Mean decrease was most distinct in axial rotation up to 83% followed by flexion-extension.

ALIF device with integrated screws at L5/S1 significantly increases segmental lordosis and anterior disc height without correlation to BMD. Primary stability in the immediate postoperative situation is mostly warranted in axial rotation. The risk of failure might be increased in extension for some patients with reduced lumbar BMD, therefore additional posterior stabilization could be considered.

For any figures or tables, please contact the authors directly.


Roger K.W. Smith

Stem cells represent an exciting biological therapy for the management of many musculoskeletal tissues that suffer degenerative disease and/or where the reparative process results in non-functional tissue (‘failed healing’). The original hypothesis was that implanted cells would differentiate into the target tissue cell type and synthesise new matrix. However, this has been little evidence that this happens in live animals compared to the laboratory, and more recent theories have focussed on the immunomodulatory effects via the release of paracrine factors that can still improve the outcome, especially since inflammation is now considered one of the central processes that drive poor tendon healing. Because of the initial ‘soft’ regulatory environment for the use of stem cells in domestic mammals, bone and fat-derived stem cells quickly established themselves as a useful treatment for naturally occurring musculoskeletal diseases in the horse more than 20 years ago (Smith, Korda et al. 2003). Since the tendinopathy in the horse has many similarities to human tendinopathy, we propose that the following challenges and, the lessons learnt, in this journey are highly relevant to the development of stem cells therapies for human tendinopathy:

Source – while MSCs can be recovered from many tissues, the predominant sources for autologous MSCs have been bone and fat. Other sources, including blood, amnion, synovium, and dental pulp have also been commercialised for allogenic treatments.

Preparation – ex vivo culture requires transport from a licensed laboratory while ‘minimally manipulated’ preparations can be prepared patient-side. Cells also need a vehicle for transport and implantation.

Delivery – transport of cells from the laboratory to the clinic for autologous ex vivo culture techniques; implantation technique (usually by ultrasound-guided injection to minimise damage to the cells (or, more rarely, incorporated into a scaffold). They can also be delivered by regional perfusion via venous or arterial routes.

Retention – relatively poor although small numbers of cells do survive for at least 5 months. Immediate loss to the lungs if the cells are administered via vascular routes. Synovially administered cells do not engraft into tendon.

Adverse effects – very safe although needle tracts often visible (but do not seen to adversely affect the outcome). Allogenic cells require careful characterisation for MHC Class II antigens to avoid anaphylaxis or reduced efficacy.

Appropriate injuries to treat – requires a contained lesion when administered via intra-lesional injection. Intrasynovial tendon lesions are more often associated with surface defects and are therefore less appropriate for treatment. Earlier treatment appears to be more effective than delayed, when implantation by injection is more challenging.

Efficacy - beneficial effects shown at both tissue and whole animal (clinical outcome) level in naturally-occurring equine tendinopathy using bone marrow-derived autologous MSCs Recent (licenced) allogenic MSC treatment has shown equivalent efficacy while intra-synovial administration of MSCs is ineffective for open intra-synovial tendon lesions.

Regulatory hurdles – these have been lighter for veterinary treatments which has facilitated their development. There has been greater regulation of commercial allogenic MSC preparations which have required EMA marketing authorisation.


N. Angrisani H. Helmholz H. Windhagen C. von der Ahe V. Scheper R. Willumeit-Römer B.M. Chathoth J. Reifenrath

There are no efficient treatment options for osteoarthritis (OA) that delay further progression. Besides osteoinduction, there is growing evidence of also anti-inflammatory, angiogenetic and neuroprotective effects of biodegradable magnesium-based biomaterials. Their use for the treatment of cartilage lesions in contrast is not well-evaluated yet.

Mg-cylinders were analysed in an in vitro and in vivo OA model. In vitro, SCP-1 stem cell line was analysed under inflammatory conditions and Mg-impact. In vivo, small Mg- and WE43 alloy-cylinders (1mm × 0,5mm) were implanted into the subchondral bone of the knee joint of 24 NZW rabbits after establishment of OA. As control, another 12 rabbits received only drill-holes. µCT-scan were performed and assessed for changes in bone volume and density. After euthanasia, cartilage was evaluated macroscopically and histologically after Safranin-O-staining. Furthermore, staining with CD271 directed antibody was performed to assess neuro-reactivity.

In vitro, an increased gene expression of extracellular matrix proteins as collagen II or aggrecan even under inflammatory conditions was observed under Mg-impact. In vivo, µCT evaluation revealed twice-elevated values for bone volume in femoral condyles with Mg-cylinders compared to controls while density remained unchanged. Cartilage showed no significant differences between the groups. Mg- and WE-samples showed significantly lower levels of CD271+ cells in the cartilage and bone of the operated joints than in non-operated joints, which was not the case in the Drilling-group. Furthermore, bone in operated knees of Drilling-group showed a strong trend to an increase in CD271+ cells compared to both Cylinder-groups. Counting of CD271+ vessels revealed that this difference was attributable to a higher amount of these vessels.

The in vitro results indicate a potential cartilage regenerative activity of the degradable Mg-based material. While so far there was no positive effect on the cartilage itself in vivo, implantation of Mg-cylinders seemed to reduce pain-mediating vessels.

Acknowledgements: This work is funded by the German Research Foundation (DFG, project number 404534760). We thank Björn Wiese for production of the cylinders.


A. Bojan P. Procter P. Karami D. Pioletti

The fixation of articular fractures, with many small osteochondral fragments, is a challenging unmet need where a bone adhesive would be a useful adjunct to standard treatments. Whilst there are no such adhesives in current clinical use, preclinical animal models have demonstrated good healing of bone in unloaded models using an adhesive based on phosphoserine modified calcium phosphate cement (PM-CPC). An ex-vivo human bone core model has shown that this adhesive bonds freshly harvested human bone. To confirm this adhesive is capable of supporting loaded osteochondral fragments a porcine model has been developed initially ex-vivo on the path to an in-vivo study. In this model bone cores, harvested from the medial knee condyle, are glued in place with the adhesive. In-vivo adjacent pairs of bone cores would be replaced with adhesive and a control with conventional pin fixation respectively. As osteochondral bone fragments have both bone and cartilage components, this suggested a dual adhesive strategy in which components designed for each tissue type are used. This concept has been explored in an ex-vivo porcine pilot study presented herewith. At the subchondral bone level, the PM-CPC was used. At the cartilage level, a second adhesive, a methacrylated phosphoserine containing hyaluronic acid (MePHa) hydrogel designed specifically for soft tissues was applied. This is a challenging model as both adhesives have to be used simultaneously in a wet field. The pilot showed that once the subchondral component is glued in place, the PM-CPC adhesive intruding into the cartilage gap can be removed before applying the cartilage adhesive. This enabled the MePHa adhesive to be injected between the cut cartilage edges and subsequently light-cured. This two-stage gluing method is demanding and an in-vivo pilot is necessary to perfect and prove the operative technique.

Acknowledgements: The human bone core project was partially financed by Innovation Fund of Västra Götaland Region, Sweden. The MePHa hydrogel work was supported by a Swiss National Fund grant # CR23I3_159301.


P. Procter G. Hulsart-Billström A. Alves M. Pujari-Palmer D. Wenner G. Insley H. Engqvist S. Larsson B. Pippenger D. Bossard

Surgeons treating fractures with many small osteochondral fragments have often expressed the clinical need for an adhesive to join such fragments, as an adjunct to standard implants. If an adhesive would maintain alignment of the articular surfaces and subsequently heal it could result in improved clinical outcomes. However, there are no bone adhesives available for clinical indications and few pre-clinical models to assess safety and efficacy of adhesive biomaterial candidates. A bone adhesive candidate based on water, α-TCP and an amino acid phosphoserine was evaluated in-vivo in a novel murine bone core model (preliminary results presented EORS 2019) in which excised bone cores were glued back in place and harvested @ 0, 3, 7, 14, 28 and 42days. Adhesive pull-out strength was demonstrated 0–28 days, with a dip at 14 days increasing to 11.3N maximum. Histology 0–42 days showed the adhesive progressively remodelling to bone in both cancellous and cortical compartments with no signs of either undesirable inflammation or peripheral ectopic bone formation. These favourable results suggested translation to a large animal model.

A porcine dental extraction socket model was subsequently developed where dental implants were affixed only with the adhesive. Biomechanical data was collected @ 1, 14, 28 and 56 days, and histology at 1,14,28 and 56 days. Adhesive strength assessed by implant pull-out force increased out to 28 days and maintained out to 56 days (282N maximum) with failure only occurring at the adhesive bone interface. Histology confirmed the adhesive's biocompatibility and osteoconductive behavior. Additionally, remodelling was demonstrated at the adhesive-bone interface with resorption by osteoclast-like cells and followed by new bone apposition and substitution by bone. Whilst the in-vivo dental implant data is encouraging, a large animal preclinical model is needed (under development) to confirm the adhesive is capable of healing, for example, loaded osteochondral bone fragments.

Acknowledgements: The murine study was supported, in part, by the Swedish Foundation for Strategic Research (#RMA15-0110).


S. Negri Ji-Hye Yea M. Gomez-Salazar S. Onggo Z. Li N. Thottappillil M. Cherief X. Xing Q. Qin R.J. Tower C.-M. Fan B. Levi A.W. James

Heterotopic ossification (HO) is defined as aberrant bone formation in extraskeletal locations. In this process, local stromal cells of mesenchymal origin abnormally differentiate, resulting in pathologic cartilage and bone matrix deposition. However, the specific cell type and mechanisms beyond this process are not well understood, in part due to the heterogeneity of progenitor cells involved. Here, a combination of single cell RNA sequencing (scRNA-Seq) and lineage tracing, defined the extent to which synovial / tendon sheath progenitor cells contribute to HO. For this purpose, a Tppp3 (tubulin polymerization-promoting protein family member 3) inducible reporter model was used, in combination with either Scx (Scleraxis) or Pdgfra (Platelet derived growth factor receptor alpha) reporter animals. Both arthroplasty-induced and tendon injury-mouse experimental HO models were utilized. ScRNA-Seq of tendon-induced traumatic HO suggested that Tppp3 is a progenitor cell marker for either osteochondral or tendon or cells. After HO induction, Tppp3 reporter+ cell population expanded in number and contributed to cartilage and bone formation in tendon and joint-associated HO. Using double reporter animals, we found that both Pdgfra+Tppp3+ and Pdgfra+Tppp3- progenitor cells produced HO-associated cartilage. Finally, the examination of human samples showed a significant population of TPPP3+ cells overlapping with osteogenic markers in areas of HO. Overall, these results provide novel observations that peritenon and synovial progenitor cells undergo abnormal osteochondral differentiation and contribute to heterotopic bone formation after trauma.


Andreas Traweger

Approximately 30% of general practice consultations for musculoskeletal pain are related to tendon disorders, causing substantial personal suffering and enormous related healthcare costs. Treatments are often prone to long rehabilitation times, incomplete functional recovery, and secondary complications following surgical repair. Overall, due to their hypocellular and hypovascular nature, the regenerative capacity of tendons is very poor and intrinsically a disorganized scar tissue with inferior biomechanical properties forms after injury. Therefore, advanced therapeutic modalities need to be developed to enable functional tissue regeneration within a degenerative environment, moving beyond pure mechanical repair and overcoming the natural biological limits of tendon healing.

Our recent studies have focused on developing biologically augmented treatment strategies for tendon injuries, aiming at restoring a physiological microenvironment and boosting endogenous tissue repair. Along these lines, we have demonstrated that the local application of mesenchymal stromal cell-derived small extracellular vesicles (sEVs) has the potential to improve rotator cuff tendon repair by modulating local inflammation and reduce fibrotic scarring. In another approach, we investigated if the local delivery of the tendon ECM protein SPARC, which we previously demonstrated to be essential for tendon maturation and tissue homeostasis, has the potential to enhance tendon healing. Finally, I will present results demonstrating the utility of nanoparticle-delivered, chemically modified mRNAs (cmRNA) to improve tendon repair.


L. Ambrosio J. Schol G. Vadalà R. Papalia D. Sakai V. Denaro

Despite promising results in attempting intervertebral disc regeneration, intradiscal cell transplantation is affected by several drawbacks, including poor viability in the harsh disc environment, low cost-effectiveness, and immunogenic/tumorigenic concerns. Recently, the development of cell-free approaches is gaining increasing interest in the field, with a particular regard towards extracellular vesicles (EVs). Nucleus pulposus cell (NPC) progenitors characterized by Tie2 expression have shown a higher chondrogenic differentiation potential compared to MSCs. The aim of this study was to investigate the putative regenerative effects of EVs isolated from Tie2-overexpressing NPC progenitors on degenerative NPCs.

NPCs were isolated from young donors and underwent an optimized culture protocol to maximize Tie2 expression (NPCsTie2+) or a standard protocol (NPCsSTD). Following EV characterization, NPC isolated from patients affected by intervertebral disc degeneration (IDD) were treated with either NPCsTie2+-EVs or NPCsSTD-EVs. Cell proliferation and viability were assessed with the CCK-8 assay. Cell apoptosis and necrosis were evaluated with the Annexin V/PI assay. Cell senescence was investigated with b-galactosidase staining. EV uptake was assessed with PKH26 staining of EVs under confocal microscopy.

Treatment with EVs isolated from young NPC donors significantly increased degenerative NPC viability, especially in samples treated with NPCsTie2+-EVs. Likewise, NPCsTie2+-EVs significantly reduced cell senescence and did not show to exert necrotic nor apoptotic effects on recipient cells. Furthermore, EV uptake was successfully observed in all treated cells.

NPCsTie2+-EVs demonstrated to significantly enhance degenerative NPC viability, senescence and apoptosis. The use of committed progenitors naturally residing the in the nucleus pulposus may optimize EV regenerative properties and constitute the basis for a new therapy for IDD.


A. Karoichan M. Tabrizian

Mesenchymal stem cells-derived extracellular vesicles (MSC-EVs) have great promise in the field of orthopaedic nanomedicine due to their regenerative, as well as immunomodulatory and anti-inflammatory properties. Researchers are interested in harnessing these biologically sourced nanovesicles as powerful therapeutic tools with intrinsic bioactivity to help treat various orthopaedic diseases and defects. Recently, a new class of EV mimetics has emerged known as nanoghosts (NGs). These vesicles are derived from the plasma membrane of ghost cells, thus inheriting the surface functionalities and characteristics of the parent cell while at the same time allowing for a more standardized and reproducible production and significantly greater yield when compared to EVs. This study aims to investigate and compare the osteoinductive potential of MSC-EVs and MSC-NGs in vitro as novel tools in the field of bone tissue engineering and nanomedicine. To carry out this investigation, MSC-EVs were isolated from serum-free MSC conditioned media through differential ultracentrifugation. The remaining cells were treated with hypotonic buffer to produce MSC-ghosts that were then homogenized and serially extruded through 400 and 200 nm polycarbonate membranes to form the MSC-NGs. The concentration, size distribution, zeta potential, and protein content of the isolated nanoparticles were assessed. Afterwards, MSCs were treated with either MSC-EVs or MSC-NGs under osteogenic conditions, and their differentiation was assessed through secreted ALP assay, qPCR, and Alizarin Red mineralization staining. Isolation of MSC-EVs and MSC-NGs was successful, with relatively similar mean diameter size and colloidal stability. No effect on MSC viability and metabolic activity was observed with either treatment. Both MSC-EV and MSC-NG groups had enhanced osteogenic outcomes compared to the control; however, a trend was observed that suggests MSC-NGs as better osteoinductive mediators compared to MSC-EVs.

Acknowledgements: The authors would like to acknowledge Canada Research Chair – Tier 1 in Regenerative Medicine and Nanomedicine, CHRP, and McGill's Faculty of Dental Medicine and Oral Health Sciences for their financial support.


M. Nardini C. Gentili A. Muraglia A. Zanirato P. Ferrari M. Formica R. Cancedda M. Mastrogiacomo

Degenerative disc disease, associated to low back pain, afflicts more than 50% of humans, and represents a major healthcare problem, especially for the pathology initiation. Current treatments range from conservative strategies to more invasive surgical techniques, such as disc removal and vertebral fusion. In the Intervertebral Disease (IVD) the nucleus pulposus (NP) degeneration is a key factor for the pathology initiation. Several tissue engineering approaches aiming to restore the appropriate NP cell (NPCs) and matrix content, were attempted by using adult stromal cells either from bone marrow or adipose tissue, chondrocytes, notochordal cells and more recently also pluripotent stem cells. However, none was fully satisfactory since the NP acid and a-vascularized environment appeared averse to the implanted heterologous cells. Several studies demonstrated the efficacy of platelet derivatives such as platelet rich plasma (PRP) in promoting the regeneration of connective tissues. We investigated the efficacy of PRP on NPCs proliferation and differentiation with the goal to propose the direct stimulation of resident cells (stimulation of endogenous cells – less invasive surgical procedure) or the implantation of NPCs expanded in vitro in the presence of PRP as therapeutic agents in IVD degeneration.

NPCs were isolated from small fragments of NP explants, cultivated in medium supplemented with PRP or FCS (standard condition control) and characterized by FACS analysis for the expression of the typical mesenchymal stem cells markers CD34, CD44, CD45, CD73, CD90 and CD105. NPCs cultured in PL showed a phenotypic profile like the cells cultured in FCS. However, compared to NPCs expanded in the presence of FCS, NPCs expanded in PRP showed a much better proliferation and differentiation capacity. NPCs differentiation was evaluated by the cell ability to produce an organized metachromatic cartilaginous matrix, confirmed by the positive immunohistochemical staining for chondrogenic markers.


S. Bagur-Cardona K. Perez-Romero K. Stiliyanov J. Calvo A. Gayà G. Barceló-Coblijn R. M. Rodriguez M. Gomez-Florit

Macrophages (Mφ) are immune cells that play a crucial role in both innate and adaptive immunity as they are involved in a wide range of physiological and pathological processes. Depending on the microenvironment and signals present, Mφ can polarize into either M1 or M2 phenotypes, with M1 macrophages exhibiting pro-inflammatory and cytotoxic effects, while M2 macrophages having immunosuppressive and tissue repair properties. Macrophages have been shown to play key roles in the development and progression or inhibition of various diseases, including cancer. For example, macrophages can stimulate tumor progression by promoting immunosuppression, angiogenesis, invasion, and metastasis. This work aimed to investigate the effect of extracellular vesicles (EVs)-derived from polarized macrophages on an osteosarcoma cell line. Monocytes were extracted from buffy coats and cultured in RPMI medium with platelet lysate or M-CSF. After 6 days of seeding, Mφ were differentiated into M1 and M2 with INF-γ/LPS and IL-4/IL-13, respectively. The medium with M1 or M2 derived EVs was collected and EVs were isolated by differential centrifugation and size exclusion chromatography and its morphology and size were characterized with SEM and NTA, respectively. The presence of typical EVs markers (CD9, CD63) was assessed by Western Blot. Finally, EVs from M1 or M2-polarized Mφ were added onto osteosarcoma cell cultures and their effect on cell viability and cell cycle, proliferation, and gene expression was assessed. The EVs showed the typical shape, size and surface markers of EVs. Overall, we observed that osteosarcoma cells responded differentially to EVs isolated from the M1 and M2-polarized Mφ. In summary, the use of Mφ-derived EVs for the treatment of osteosarcoma and other cancers deserves further study as it could benefit from interesting traits of EVs such as low immunogenicity, nontoxicity, and ability to pass through tissue barriers.

Acknowledgements: Carlos III Health Institute and the European Social Fund for contract CP21/00136 and project PI22/01686.


Jorge Mineiro

In March 2020, COVID-19 was declared a pandemic by the World Health Organization. The pandemic imposed drastic changes in our social and professional routine. Professionally at all levels our hospital tasks were changed and prioritized. Surgeons and residents were deployed on rotations to fields other than their expertise in orthopaedics. Health-care education received major changes in these challenging times, and students did face difficulties in receiving education, as well as training due to limited clinical and surgical exposure.

In response to the WHO regulations, most of the teaching centres and hospitals worldwide have adopted the web-based teaching and learning model to continue the education and training of orthopaedic residents. These results brought significant changes to the training experience in orthopaedic surgery in combination with the fact that clinical duty hours and case volume were substantially reduced.

In what concerns orthopaedic journal publications, the Covid-19 pandemic resulted in a decline in the annual publication rate for the first time in over 20 years. Although not uniform, the reduction was most likely due to multifactorial causes.

Regarding the appraisal at the end of training, at the Orthopaedic European Board Examination we were able to verify that the outcome at the written part 1 exam was good, equivalent to the outcome prior to the pandemic. However the oral viva was much worse, probably due to the fact that residents skipped much of the clinical and surgical teaching and exposure during 2020 and 2021. At the end of training, theoretical/factual knowledge was good but poor from the clinical practical experience.


J. Frese AP Schulz B. Kowald U.-J. Gerlach K.-H. Frosch R. Schoop

In a consecutive retrospective analysis of 190 patients treated with the Masquelet technique at the BG Klinikum Hamburg from January 2012 to January 2022, defect-specific features such as the extent and morphology of the defect were recorded, and their influence on the time to reach full weight-bearing of the affected limb was investigated.

A total of 217 defects were treated in 190 patients using the Masquelet technique. 70% of all defects were located in the tibia, followed by 22% in the femur and only about 7% in the upper extremity. The average length of all defects was 58 mm (+/−31 mm), with the largest defect measuring 180 mm and the smallest measuring 20 mm. 89% of the patients achieved full weight-bearing at the end of therapy. The average time from initiation of therapy to reaching safe full weight-bearing was 589 days. There was a significant correlation between defect length and time to reach full weight-bearing (p = 0.0134). These results could serve as a basis for creating a score for prognostics and evaluation of bone healing after treatment with the Masquelet technique. Additionally, the results could help guide indications for secondary stabilization using internal fixation.


T. Pastor E. Cattaneo T. Pastor B. Gueorguiev M. Windolf J. Buschbaum

Freehand distal interlocking of intramedullary nails remains a challenging task. If not performed correctly it can be a time consuming and radiation expensive procedure. Recently, the AO Research Institute developed a new training device for Digitally Enhanced Hands-on Surgical Training (DEHST) that features practical skills training augmented with digital technologies, potentially improving surgical skills needed for distal interlocking. Aim of the study: To evaluate weather training with DEHST enhances the performance of novices without surgical experience in free-hand distal nail interlocking compared to a non-trained group of novices.

20 novices were assigned in two groups and performed distal interlocking of a tibia nail in an artificial bone model. Group 1: DEHST trained novices (virtual locking of five nail holes during one hour of training). Group 2: untrained novices without DEHST training. Time, number of x-rays, nail hole roundness, critical events and success rates were compared between the groups.

Time to complete the task (sec.) and x-ray exposure (µGcm2) were significantly lower in Group1 414.7 (290–615) and 17.8 (9.8–26.4) compared to Group2 623.4 (339–1215) and 32.6 (16.1–55.3); p=0.041 and 0.003. Perfect circle roundness (%) was 95.0 (91.1–98.0) in Group 1 and 80.8 (70.1–88.9) in Group 2; p<0.001. In Group 1 90% of the participants achieved successful completion of the task (hit the nail with the drill), whereas only 60% of the participants in group 2 achieved this; p=0.121.

Training with DEHST significantly enhances the performance of novices without surgical experience in distal interlocking of intramedullary nails. Besides radiation exposure and operation time the com-plication rate during the operation can be significantly reduced.


J. Lin P.K. Chen Z. J. Tan Y. Sun W.K. Tam D. Ao W. Shen V. Leung K. M. C. Cheung M.K.T. To

Silver nanoparticles (AgNPs) possess anti-inflammatory activities and have been widely deployed for promoting tissue repair. Here we explored the efficacy of AgNPs on functional recovery after spinal cord injury (SCI). Our data indicated that, in a SCI rat model, local AgNPs delivery could significantly recover locomotor function and exert neuroprotection through reducing of pro-inflammatory M1 survival. Furthermore, in comparison with Raw 264.7-derived M0 and M2, a higher level of AgNPs uptake and more pronounced cytotoxicity were detected in M1. RNA-seq analysis revealed the apoptotic genes in M1 were upregulated by AgNPs, whereas in M0 and M2, pro-apoptotic genes were downregulated and PI3k-Akt pathway signaling pathway was upregulated. Moreover, AgNPs treatment preferentially reduced cell viability of human monocyte-derived M1 comparing to M2, supporting its effect on M1 in human. Overall, our findings reveal AgNPs could suppress M1 activity and imply its therapeutic potential in promoting post-SCI motor recovery.


S. Singh S. Dhar S. Kale

The management of comminuted metaphyseal fractures is a technical challenge and satisfactory outcomes of such fixations often remain elusive. The small articular fragments and bone loss often make it difficult for standard fixation implants for proper fixation. We developed a novel technique to achieve anatomical reduction in multiple cases of comminuted metaphyseal fractures at different sites by employing the cantilever mechanism with the help of multiple thin Kirschner wires augmented by standard fixation implants.

We performed a retrospective study of 10 patients with different metaphyseal fractures complicated by comminution and loss of bone stock. All patients were treated with the help of cantilever mechanism using multiple Kirschner wires augmented by compression plates. All the patients were operated by the same surgeon between November 2020 to March 2021 and followed up till March 2023. Surgical outcomes were evaluated according to the clinical and radiological criteria.

A total of 10 patients were included in the study. Since we only included patients with highly unstable and comminuted fractures which were difficult to fix with traditional methods, the number of patients in the study were less. All 10 patients showed satisfactory clinical and radiological union at the end of the study with good range of motion. One of the patient in the study had post-operative wound complication which was managed conservatively with regular dressings and oral antibiotics.

Comminuted metaphyseal fractures might differ in pattern and presentation with every patient and there can be no standard treatment for all. The cantilever technique of fracture fixation is based on the principle of cantilever mechanism used in bridges and helps achieve good anatomical reduction and fixation. It provides a decent alternative when standard modes of fixation don't give desired result owing to comminuted nature of fractures and deficiency of bone stock.


V. Oliveira

Primary bone tumors are rare, complex and highly heterogeneous. Its diagnostic and treatment are a challenge for the multidisciplinary team. Developments on tumor biomarkers, immunohistochemistry, histology, molecular, bioinformatics, and genetics are fundamental for an early diagnosis and identification of prognostic factors. The personalized medicine allows an effective patient tailored treatment. The bone biopsy is essential for diagnosis. Treatment may include systemic therapy and local therapy. Frequently, a limb salvage surgery includes wide resection and reconstruction with endoprosthesis, biological or composites. The risk for local recurrence and distant metastases depends on the primary tumor and treatment response.

Cancer patients are living longer and bone metastases are increasing. Bone is the third most frequently location for distant lesions. Bone metastases are associated to pain, pathological fractures, functional impairment, and neurological deficits. It impacts survival and patient quality of life. The treatment of metastatic disease is a challenge due to its complexity and heterogeneity, vascularization, reduced size and limited access. It requires a multidisciplinary treatment and depending on different factors it is palliative or curative-like treatment. For multiple bone metastases it is important to relief pain and increases function in order to provide the best quality of life and expect to prolong survival. Advances in nanotechnology, bioinformatics, and genomics, will increase biomarkers for early detection, prognosis, and targeted treatment effectiveness. We are taking the leap forward in precision medicine and personalized care.


M.V. Lipreri M. Cortini N. Baldini S. Avnet

Osteosarcoma is a highly malignant primary tumor of bone tissue. The 5-year survival rate of patients with metastasis is below 20% and this scenario is unchanged in the last two decades, despite great efforts in pre-clinical and clinical research. Traditional preclinical models of osteosarcoma do not consider the whole complexity of its microenvironment, leading to poor correlation between in vitro/in vivo results and clinical outcomes. Spheroids are a promising in vitro model to mimic osteosarcoma and perform drug-screening tests, as they (i) reproduce the microarchitecture of the tumor, (ii) are characterized by hypoxic regions and necrotic core as the in vivo tumor, (iii) and recapitulate the chemo-resistance phenomena. However, to date, the spheroid model is scarcely used in osteosarcoma research.

Our aim is to develop a customized culture dish to grow and characterize spheroids and to perform advanced drug-screening tests. The resulting platform must be adapted to automated image acquisition systems, to overcome the drawbacks of commercial spheroids platforms.

To this purpose, we designed and developed a micro-patterned culture dish by casting agarose on a 3D printed mold from a CAD design. We successfully obtained viable and reproducible homotypic osteosarcoma spheroids, with two different cells lines from osteosarcoma (i.e., 143b and MG-63). Using the platform, we performed viability assays and live fluorescent stainings (e.g., Calcein AM) with low reagent consumption. Moreover, the culture dish was validated as drug screening platform, administrating Doxorubicin at different doses, and evaluating its effect on OS spheroids, in terms of morphology and viability. This platform can be considered an attractive alternative to the highly expensive commercial spheroid platforms to obtain homogeneous and reproducible spheroids in a high-throughput and cost effective mode.


B.I. Zorba Ö. Boyacioğlu T. Çağlayan T. Reçber İ. Eroğlu E. Nemutlu P. Korkusuz

Osteosarcoma is common in children and adolescents with high mortality due to rapid progression. Therapeutic approaches for osteosarcoma are limited and may cause side effects. Cannabinoid ligands exert antiproliferative, apoptotic effect in cancer cells via CB1/2 or TRPV1 receptors. In this study, we hypothesized that synthetic specific CB2R agonist CB65 might have an antiproliferative and apoptotic effect on osteosarcoma cell lines in vitro. If so, this agent might be a chemotherapeutic candidate for osteosarcoma, with prolonged release, increased stability and bioavailability when loaded into a liposomal system. We first determined CB2 receptor expression in MG63 and Saos-2 osteosarcoma cells by qRT- PCR and FCM. CB65 reduced proliferation in osteosarcoma cells by WST-1 and RTCA. IC50 for MG63 and Saos-2 cells were calculated as 1.11×10-11 and 4.95×10-11 M, respectively. The antiproliferative effect of CB65 on osteosarcoma cells was inhibited by CB2 antagonist AM630. IC50 of CB65 induced late apoptosis of MG63 and Saos-2 cells at 24 and 48 hours, respectively by FCM. CB65 was loaded into the liposomal system by thin film hydration method and particle size, polydispersity index, and zeta potentials were 141.7±0.6 nm, 0.451±0.026, and -10.9±0.3 mV, respectively. The CB65-loaded liposomal formulation reduced MG63 and Saos-2 cell proliferation by RTCA. IC50 of CB65 and CB65-loaded liposomal formulation induced late apoptosis of MG63 and Saos-2 cells at 24 and 48 hours, respectively, by FCM. Scratch width was higher in CB65 and CB65-loaded liposome-treated cells compared to control. In this study, the real-time antiproliferative and apoptotic effect of synthetic specific CB2 agonist CB65 in osteosarcoma cell lines was demonstrated for the first time, and the real time therapeutic window was determined. The CB65-loaded liposomal formulation presents a potential treatment option that can be translated to clinic following its validation within animal models and production under GMP conditions.


M. Riool R. Li L.v. Hofwegen L. de Boer J.A. Loontjens S.A.J. Zaat

Infection of implanted medical devices (biomaterials), like titanium orthopaedic implants, can have disastrous consequences, including removal of the device. These so-called biomaterial-associated infections (BAI) are mainly caused by Staphylococcus aureus and Staphylococcus epidermidis. To prevent biofilm formation using a non-antibiotic based strategy, we aimed to develop a novel permanently fixed antimicrobial coating for titanium devices based on stable immobilized quaternary ammonium compounds (QACs).

Medical grade titanium implants were dip-coated in subsequent solutions of hyperbranched polymer, polyethyleneimine and 10 mM sodium iodide, and ethanol. The QAC-coating was characterized using water contact angle measurements, scanning electron microscopy, FTIR, AFM and XPS. The antimicrobial activity of the coating was evaluated against S. aureus strain JAR060131 and S. epidermidis strain ATCC 12228 using the JIS Z 2801:2000 surface microbicidal assay. Lastly, we assessed the in vivo antimicrobial activity in a mouse subcutaneous implant infection model with S. aureus administered locally on the QAC-coated implants prior to implantation to mimic contamination during surgery.

Detailed material characterization of the titanium samples showed the presence of a homogenous and stable coating layer at the titanium surface. Moreover, the coating successfully killed S. aureus and S. epidermidis in vitro. The QAC-coating strongly reduced S. aureus colonization of the implant surface as well as of the surrounding tissue, with no apparent macroscopic signs of toxicity or inflammation in the peri-implant tissue at 1 and 4 days after implantation.

An antimicrobial coating with stable quaternary ammonium compounds on titanium has been developed which holds promise to prevent BAI. Non-antibiotic-based antimicrobial coatings have great significance in guiding the design of novel antimicrobial coatings in the present, post-antibiotic era.

Acknowledgements: This research was financially supported by the Health∼Holland/LSH-TKI call 2021–2022, project 25687, NACQAC: ‘Novel antimicrobial coatings with stable non-antibiotic Quaternary Ammonium Compounds and photosensitizer technology'.


E. Wehrle

Fracture healing is a spatially controlled process involving crosstalk of multiple tissues. To precisely capture and understand molecular mechanism underlying impaired healing, there is a need to integrate spatially-resolved molecular analyses into preclinical fracture healing models. I will present our recent data obtained by spatial transcriptomics of musculoskeletal samples from fracture healing studies in mice. Subsequently, I will show how spatial transcriptomics can be integrated into multimodal approaches in preclinical fracture healing models. In combination with established in vivo imaging and emerging omics techniques, spatially-resolved analyses have the potential to elucidate the molecular mechanisms underlying impaired healing with optimization of treatments.


J. Grammens L. F.A. Pereira F. Danckaers J. Vanlommel A. Van Haver P. Verdonk J. Sijbers

Currently implemented accuracy metrics in open-source libraries for segmentation by supervised machine learning are typically one-dimensional scores [1]. While extremely relevant to evaluate applicability in clinics, anatomical location of segmentation errors is often neglected.

This study aims to include the three-dimensional (3D) spatial information in the development of a novel framework for segmentation accuracy evaluation and comparison between different methods.

Predicted and ground truth (manually segmented) segmentation masks are meshed into 3D surfaces. A template mesh of the same anatomical structure is then registered to all ground truth 3D surfaces. This ensures all surface points on the ground truth meshes to be in the same anatomically homologous order. Next, point-wise surface deviations between the registered ground truth mesh and the meshed segmentation prediction are calculated and allow for color plotting of point-wise descriptive statistics. Statistical parametric mapping includes point-wise false discovery rate (FDR) adjusted p-values (also referred to as q-values).

The framework reads volumetric image data containing the segmentation masks of both ground truth and segmentation prediction. 3D color plots containing descriptive statistics (mean absolute value, maximal value,…) on point-wise segmentation errors are rendered. As an example, we compared segmentation results of nnUNet [2], UNet++ [3] and UNETR [4] by visualizing the mean absolute error (surface deviation from ground truth) as a color plot on the 3D model of bone and cartilage of the mean distal femur.

A novel framework to evaluate segmentation accuracy is presented. Output includes anatomical information on the segmentation errors, as well as point-wise comparative statistics on different segmentation algorithms. Clearly, this allows for a better informed decision-making process when selecting the best algorithm for a specific clinical application.


A. Emmanuel

Non-linear methods in statistical shape analysis have become increasingly important in orthopedic research as they allow for more accurate and robust analysis of complex shape data such as articulated joints, bony defects and cartilage loss. These methods involve the use of non-linear transformations to describe shapes, rather than the traditional linear approaches, and have been shown to improve the precision and sensitivity of shape analysis in a variety of applications. In orthopedic research, non-linear methods have been used to study a range of topics, including the analysis of bone shape and structure in relation to osteoarthritis, the assessment of joint deformities and their impact on joint function, and the prediction of patient outcomes following surgical interventions. Overall, the use of non-linear methods in statistical shape analysis has the potential to advance our understanding of the relationship between shape and function in the musculoskeletal system and improve the diagnosis and treatment of orthopedic conditions.


K. Duquesne A. Emmanuel

For many years, marker-based systems have been used for motion analysis. However, the emergence of new technologies, such as 4D scanners provide exciting new opportunities for motion analysis. In 4D scanners, the subjects are measured as a dense mesh, which enables the use of shape analysis techniques. In this talk, we will explore how the combination of the rising new motion analysis methods and shape modelling may change the way we think about movement and its analysis.


A. Van Oevelen K. Duquesne M. Peiffer J. Victor E. Audenaert

Intra-articular cartilage pressure distribution in the knee joint is critical in the understanding of osteoarthritis. Combining personalized statistical modeling of the morphological characteristics with discrete element modeling enables patient-specific predictions of the pressure on the tibial plateau. However, modeling of the meniscus during gait is complicated by the dynamic nature of the structure. Nevertheless, the position of the meniscus has a substantial impact on intra-articular stress distribution. Therefore, the focus of this presentation will be on how modeling of meniscal movement during knee flexion improves insight in general meniscal kinematics for the use in tibiofemoral stress distribution calculations.


M. Peiffer

Syndesmotic ankle lesions involve disruption of the osseous tibiofibular mortise configuration as well as ligamentous structures stabilizing the ankle joint. Incomplete diagnosis and maltreatment of these injuries is frequent, resulting in chronic pain and progressive instability thus promoting development of ankle osteoarthritis in the long term. Although the pathogenesis is not fully understood, abnormal mechanics has been implicated as a principal determinant of ankle joint degeneration after syndesmotic ankle lesions. Therefore, the focus of this presentation will be on our recent development of a computationally efficient algorithm to calculate the contact pressure distribution in patients with a syndesmotic ankle lesion, enabling us to stratify the risk of OA development in the long term and thereby guiding patient treatment.


I.V. den Borre

Geometric deep learning is a relatively new field that combines the principles of deep learning with techniques from geometry and topology to analyze data with complex structures, such as graphs and manifolds. In orthopedic research, geometric deep learning has been applied to a variety of tasks, including the analysis of imaging data to detect and classify abnormalities, the prediction of patient outcomes following surgical interventions, and the identification of risk factors for degenerative joint disease. This review aims to summarize the current state of the field and highlight the key findings and applications of geometric deep learning in orthopedic research. The review also discusses the potential benefits and limitations of these approaches and identifies areas for future research. Overall, the use of geometric deep learning in orthopedic research has the potential to greatly advance our understanding of the musculoskeletal system and improve patient care.


A. Ghaffari P.D. Clasen R.V. Boel A. Kappel T. Jakobsen S. Kold O. Rahbek

Wearable inertial sensors can detect abnormal gait associated with knee or hip osteoarthritis (OA). However, few studies have compared sensor-derived gait parameters between patients with hip and knee OA or evaluated the efficacy of sensors suitable for remote monitoring in distinguishing between the two. Hence, our study seeks to examine the differences in accelerations captured by low-frequency wearable sensors in patients with knee and hip OA and classify their gait patterns.

We included patients with unilateral hip and knee OA. Gait analysis was conducted using an accelerometer ipsilateral with the affected joint on the lateral distal thighs. Statistical parametric mapping (SPM) was used to compare acceleration signals. The k-Nearest Neighbor (k-NN) algorithm was trained on 80% of the signals' Fourier coefficients and validated on the remaining 20% using 10-fold cross-validation to classify the gait patterns into hip and knee OA.

We included 42 hip OA patients (19 females, age 70 [63–78], BMI of 28.3 [24.8–30.9]) and 59 knee OA patients (31 females, age 68 [62–74], BMI of 29.7 [26.3–32.6]). The SPM results indicated that one cluster (12–20%) along the vertical axis had accelerations exceeding the critical threshold of 2.956 (p=0.024). For the anteroposterior axis, three clusters were observed exceeding the threshold of 3.031 at 5–19% (p = 0.0001), 39–54% (p=0.00005), and 88–96% (p = 0.01). Regarding the mediolateral axis, four clusters were identified exceeding the threshold of 2.875 at 0–9% (p = 0.02), 14–20% (p=0.04), 28–68% (p < 0.00001), and 84–100% (p = 0.004). The k-NN model achieved an AUC of 0.79, an accuracy of 80%, and a precision of 85%.

In conclusion, the Fourier coefficients of the signals recorded by wearable sensors can effectively discriminate the gait patterns of knee and hip OA. In addition, the most remarkable differences in the time domain were observed along the mediolateral axis.


Ö.F. İlicepinar M. Imir B.C. Cengiz S. Gürses Y. Menderes E. Turhan G. Dönmez F. Korkusuz

Hop tests are used to determine return to sports after ACL reconstruction. They mostly measure distance and symmetry but do not assess kinematics and kinetics. Recently, biomechanical evaluations have been incorporated into these functional jump tests for the better assessment of return to sport. We assessed the sagittal plane range of motion (ROM) of the knee, the deviation axis of rotation (DAOR), and the vertical ground reaction force (vGRF) normalized to body weight in nine healthy participants during the single leg (SLH) and crossover hop tests (COHT).

Participants' leg lengths were measured. Jumping distances were marked in the test area as being 4/5 of the leg length. Four sensors were placed on the thighs, the legs and the feet. These body parts were handled as a single rigid body. Eight 480 Hz cameras were used to capture the movements of these rigid bodies. vGRF at landing were measured using a force plate (Bertec, Inc, USA). The ROM of the knee joint and the DAOR were obtained from kinematic data.

Participants' joint kinematics metrics were similar in within-subjects statistical tests for SLH and COHT. We therefore asked whether the repeated vGRF normalized to body weight will be similar in both legs during these jumps. Joint kinematics metrics however were different in between subjects indicating the existence of a personalized jumping strategy. These hop tests can be recorded at the beginning of the training season for each individual, which can establish a comparative evaluation database for prospective lower extremity injury recovery and return to sport after ACL injury.


L. Stroobant E. Jacobs N. Arnout S. Van Onsem A. Burssens J. Victor

7–20 % of the patients with a total knee arthroplasty (TKA) are dissatisfied without an indication for revision. Therapeutic options for this patient population with mostly a lack of quadriceps strength are limited. The purpose of this study is to evaluate the effect of six weeks low load resistance training with blood flow restriction (BFR) on the clinical outcome in these unhappy TKA patients.

Thirty-one unhappy TKA patients (of the scheduled fifty patients) without mechanical failure were included in this prospective study since 2022. The patients participate in a supervised resistance training combined with BFR, two times a week during nine weeks. Patients were evaluated by the Knee Osteoarthritis Outcome Score (KOOS), Knee Society Score: satisfaction (KSSs) and the Pain Catastrophizing Scale (PCS). Functionality was tested using the Six Minute Walk Test (6MWT) and the 30-Second Chair Stand Test (30CST). Follow-up took place at six weeks, three months and six months after the start.

Six weeks training with BFR provided statistically significant improvements in all the KOOS subscales compared to the baseline, especially for symptoms (55.1 (±15.4) versus 48.0 (±16.5); p<0.001), activities in daily living (50.3 (±21.1) versus 43.7 (±17.2); p<0.00) and quality of life (24.6 (±18.5) versus 17.3 (±13.0); p<0.001). The PCS reduced from 27.4 (±11.0) to 23.2 (±11.4) at six weeks (p<0.01), whereas the KSSs increased from 11.8 (±6.5) to 14.9 (±7.6) (p=0.021). Both the 6MWT and the 30CST improved statistically significant from respectively 319.7 (±15.0) to 341.6m (±106.5) (p<0.01) and 8.6 (±3.9) to 9.3 times (±4.5) (p<0.01).

Blood flow restriction appears to enhance the quality of life and functional performance of unhappy TKA patients. Based on these preliminary results, BFR seems to be a promising and valuable alternative for these TKA patients with limited therapeutic options.


I. Zderic S. Warner K. Stoffel W. Woodburn R. Castle J. Penman E. Saura-Sanchez D.L. Helfet B. Gueorguiev C. Sommer

Treatment of both simple and complex patella fractures is a challenging clinical problem. The aim of this study was to investigate the biomechanical performance of recently developed lateral rim variable angle locking plates versus tension band wiring used for fixation of simple and complex patella fractures.

Twelve pairs of human anatomical knees were used to simulate either two-part transverse simple AO/OTA 34C1 or five-part complex AO/OTA 34C3 patella fractures by means of osteotomies, with each fracture model created in six pairs. The complex fracture pattern was characterized by a medial and a lateral proximal fragment, together with an inferomedial, an inferolateral, and an inferior fragment mimicking comminution around the distal patellar pole. The specimens with simple fractures were pairwise assigned for fixation with either tension band wiring through two parallel cannulated screws, or a lateral rim variable angle locking plate. The knees with complex fractures were pairwise treated with either tension band wiring through two parallel cannulated screws plus circumferential cerclage wiring, or a lateral rim variable angle locking plate.

Each specimen was tested over 5000 cycles by pulling on the quadriceps tendon, simulating active knee extension and passive knee flexion within the range of 90° flexion to full knee extension. Interfragmentary movements were captured via motion tracking.

For both fracture types, the longitudinal and shear articular displacements measured between the proximal and distal fragments at the central patella aspect between 1000 and 5000 cycles, together with the relative rotations of these fragments around the mediolateral axis were all significantly smaller following the lateral rim variable angle locked plating compared with tension band wiring, p<0.01.

Lateral rim locked plating of both simple and complex patella fractures provides superior construct stability versus tension band wiring under dynamic loading.


T.M. Grupp

In severe cases of total knee & hip arthroplasty, where off-the-shelf implants are not suitable (i.e., in cases with extended bone defects or periprosthetic fractures), 3D-printed custom-made knee & hip revision implants out of titanium or cobalt-chromium alloy represent one of the few remaining clinical treatment options. Design verification and validation of such custom-made implants is very challenging. Therefore, a methodology was developed to support surgeons and engineers in their decision on whether a developed design is suitable for the specific case. A novel method for the pre-clinical testing of 3D-printed custom-made knee implants has been established, which relies on the biomechanical test and finite element analysis (FEA) of a comparable clinically established reference implant. The method comprises different steps, such as identification of the main potential failure mechanism, reproduction of the biomechanical test of the reference implant via FEA, identification of the maximum value of the corresponding FEA quantity of interest at the required load level, definition of this value as the acceptance criterion for the FEA of the custom-made implant, reproduction of the biomechanical test with the custom-made implant via FEA, decision making for realization or re-design based on the acceptance criterion is fulfilled or not. Exemplary cases of custom-made knee & hip implants were evaluated with this new methodology. The FEA acceptance criterion derived from the reference implants was fulfilled in both custom-made implants and subsequent biomechanical tests verified the FEA results. The suggested method allows a quantitative evaluation of the biomechanical properties of custom-made knee & hip implant without performing physical bench testing. This represents an important contribution to achieve a sustainable patient treatment in complex revision total knee & hip arthroplasty with custom-made 3D printed implants in a safe and timely manner.


B. Richter

An overview about 3D printing technology in orthopaedic applications will be given based on examples. The process from early prototypes to certified implants coming from serial production will be demonstrated also considering relevant surrounding conditions. Today's focus is mostly on orthopaedic implants, but there is a high potential for new implant-related surgical instrument solutions taking into account up-coming clinical demands and user needs accessible by actual 3D printing technologies.


F.N. Depboylu

Production of porous titanium bone implants is a highly promising research and application area due to providing high osseointegration and achieving the desired mechanical properties. Production of controlled porosity in titanium implants is possible with laser powder bed fusion (L- PBF) technology. The main topics of this presentation includes the L-PBF process parameter optimization to manufacture thin walls of porous titanium structures with almost full density and good mechanical properties as well as good dimensional accuracy. Moreover, the cleaning and coating process of these structures to further increase osseointegration and then in-vitro biocompatibility will be covered.


H. Jahr

AM specifically allows for cost-efficient production of patient-specific Orthopaedic medical devices with unusual designs and properties. A porous design allows to adjust the stiffness of metallic implants to that of the host bone. Beyond traditional metals, like titanium alloys, this talk will review the present state-of-the-art of directly printed absorbable metal families. Physicochemical, mechanical and biological properties of standardized design prototypes from all currently available metal families will be compared and their clinical application potential discussed. The impact of in vitro test environments on comparative corrosion behavior, post manufacturing aspects, and the recent status quo in biocompatibility testing and present knowledge gaps will be addressed.


G. Graziani

Functionalization of biomimetic nanomaterials allows to reproduce the composition of native bone, permitting better regeneration, while nanoscale surface morphologies provide cues for cell adhesion, proliferation and differentiation. Functionalization of 3D printed and bioprinted constructs, by plasma-assisted deposition of calcium phosphates-based (CaP) nanostructured coatings and by nanoparticles, respectively, will be presented. Stoichiometric and ion doped CaP- based nanocoatings, including green materials (mussel seashells and cuttlefish bone), will be introduced to guide tissue regeneration. We will show interactions between biomimetic surfaces and MSCs to address bone regeneration and SAOS-2 cells for bone tumor models. Our results show that combining AM and nanostructured biomimetic films permits to reproduce the architecture and the mechanical and compositional characteristics of bone. Stability behavior of the coatings, as well as MSCs behavior strongly depend on the starting CaP material, with more soluble CaPs and ion-doped ones showing better biological behavior. Green materials appear promising, as biomimetic films can be successfully obtained upon conversion of the marine precursors into hydroxyapatite. Last-not-least, nanoparticles-loaded scaffolds could be bioprinting without loss of cell viability, but ink characteristics depend on ion-doping as demonstrated for SAOS-2 cells over 14 days of culture. Biomimetic nanomaterials for functionalization in AM is a promising approach for bone modelling and regeneration.


V. Platania N.N. Tavernaraki I. Gontika E. Fragiadaki N. Triantopoulou H.A. Papadaki K. Alpantaki M. Vidaki M. Chatzinikolaidou

Biofabrication is a popular technique to produce personalized constructs for tissue engineering. In this study we combined laponite (Lap), gellan gum (GG) with platelet-rich plasma (PRP) aiming to enhance the endothelial regeneration through the synergistic effects of their individual properties. Laponite has the ability to form porous three-dimensional networks mimicking the extracellular matrix structure, and PRP delivery of growth factors stimulates the endothelial cell proliferation and migration, offering a composite bioink for cell growth and support. The sustained release of these growth factors from the GG-laponite-PRP composite material over time provides a continuous source of stimulation for the cells, leading to more effective tissue engineering strategies for endothelial tissue regeneration. Four blend compositions comprising 1% w/v GG and 0.5 or 1% w/v Lap and 25% v/v PRP were combined with Wharton jelly mesenchymal stem cells (WJ-MSCs) and bioprinted into vessel-like structures with an inner diameter of 3 mm and a wall thickness of 1 mm. Stress/strain analysis revealed the elastomeric properties of the hydrogels with Young modulus values of 10 MPa. Increasing the Lap concentration led to a non-significant decrease of swelling ratio from 93 to 91%. Live/dead assay revealed cell viability of at least 76%, with the 0.5%Lap-GG viability exceeding 99% on day 21. Gradual increase of glycosaminoglycans accumulation and collagen production indicate promotion of ECM formation. The expression and membranous localization of PECAM-1 from day 7 and the granular intracellular localization of vWF after 2 weeks demonstrate in vitro endothelial functionality. In vivo subcutaneous implantation indicated the absence of any adverse immunological reactions. The results reveal the expression of both vWF and PECAM-1 by WJ-MSCs entrapped in all four construct compositions with significantly higher expression of vWF in the presence of PRP.


B. Charbonnier L. Guyon N. Touya M. Dutilleul J. Véziers P. Maitre O. Gauthier P. Corre P. Weiss

Developments in the field of additive manufacturing have allowed significant improvements in the design and production of scaffolds with biologically relevant features to treat bone defects. Unfortunately, the workflow to generate personalized scaffolds is source of inaccuracies leading to a poor fit between the implant and patients' bone defects. In addition, scaffolds are often brittle and fragile, uneasing their handling by surgeons, with significant risks of fracture during their insertion in the defect. Consequently, we developed organo-mineral cementitious scaffolds displaying evolutive mechanical properties which are currently being evaluated to treat maxillofacial bone deformities in veterinary clinics. Treatment of dog patients was approved by ethic and welfare committees (CERVO-2022-14-V). To date, 8 puppies with cleft palate/lip deformities received the following treatment. Two weeks prior surgery, CT-scan of patient's skull was performed to allow for surgical planning and scaffold designing. Organo-mineral printable pastes were formulated by mixing an inorganic cement precursor (α-Ca3(PO4)2) to a self-reticulating hydrogel (silanized hyaluronic acid) supplemented with a viscosifier (hydroxymethylpropylcellulose). Scaffolds were produced by robocasting of these pastes. Surgical interventions included the reconstruction of soft tissues, and the insertion of the scaffold soaked with autologous bone marrow. Bone formation was monitored 3 and 6 months after reconstruction, and a biopsy at 6 months was performed for more detailed analyses. Scaffolds displayed great handling properties and were inserted within bone defects without significant issue with a relevant bone edges/scaffold contact. Osteointegration of the scaffolds was observed after 3 months, and regeneration of the defect at 6 months seemed quite promising. Preliminary results have demonstrated a potential of the set-up strategy to treat cleft lip/palate deformities in real, spontaneous clinical setting. Translation of these innovative scaffolds to orthopedics is planned for a near future.


M.T. Rodrigues A.F. Almeida M.S. Miranda A. Vinhas A. I. Gonçalves M.E. Gomes

Chronic inflammatory events have been associated to almost every chronic disease, including cardiovascular-, neurodegenerative- and autoimmune- diseases, cancer, and host-implant rejection. Given the toll of chronic inflammation in healthcare and socioeconomical costs developing strategies to resolve and control chronic states of inflammation remain a priority for the significant benefit of patients.

Macrophages (Mφ) hold a central role both in the initiation and resolution of inflammatory events, assuming different functional profiles. The outstanding features of Mφ counting with the easy access to tissues, and the extended networking make Mφ excellent candidates for precision therapy. Moreover, sophisticated macrophage-oriented systems could offer innovative immune-regulatory alternatives to effectively regulate chronic environments that traditional pharmacological agents cannot provide.

We propose magnetically assisted systems for balancing Mφ functions at the injury site. This platform combines polymers, inflammatory miRNA antagonists and magnetically responsive nanoparticles to stimulate Mφ functions towards pro-regenerative phenotypes. Strategies with magnetically assisted systems include contactless presentation of immune-modulatory molecules, cell internalization of regulatory agents for functional programming via magnetofection, and multiple payload delivery and release.

Overall, Mφ-oriented systems stimulated pro-regenerative functions of Mφ supporting magnetically assisted theranostic nanoplatforms for precision therapies, envisioning safer and more effective control over the distribution of sensitive nanotherapeutics for the treatments of chronical inflammatory conditions.

Acknowledgements: ERC CoG MagTendon No.772817; FCT Doctoral Grant SFRD/BD/144816/2019, and TERM

RES Hub (Norte-01-0145-FEDER-022190).


S.J.P. Callens R. Burdis M. Cihova J.A. Kim Q.Y. Lau M. M. Stevens

Cells typically respond to a variety of geometrical cues in their environment, ranging from nanoscale surface topography to mesoscale surface curvature. The ability to control cellular organisation and fate by engineering the shape of the extracellular milieu offers exciting opportunities within tissue engineering. Despite great progress, however, many questions regarding geometry-driven tissue growth remain unanswered.

Here, we combine mathematical surface design, high-resolution microfabrication, in vitro cell culture, and image-based characterization to study spatiotemporal cell patterning and bone tissue formation in geometrically complex environments. Using concepts from differential geometry, we rationally designed a library of complex mesostructured substrates (101-103 µm). These substrates were accurately fabricated using a combination of two-photon polymerisation and replica moulding, followed by surface functionalisation. Subsequently, different cell types (preosteoblasts, fibroblasts, mesenchymal stromal cells) were cultured on the substrates for varying times and under varying osteogenic conditions. Using imaging-based methods, such as fluorescent confocal microscopy and second harmonic generation imaging, as well as quantitative image processing, we were able to study early-stage spatiotemporal cell patterning and late-stage extracellular matrix organisation. Our results demonstrate clear geometry-dependent cell patterning, with cells generally avoiding convex regions in favour of concave domains. Moreover, the formation of multicellular bridges and collective curvature-dependent cell orientation could be observed. At longer time points, we found clear and robust geometry-driven orientation of the collagenous extracellular matrix, which became apparent with second harmonic generation imaging after ∼2 weeks of culture.

Our results highlight a key role for geometry as a cue to guide spatiotemporal cell and tissue organisation, which is relevant for scaffold design in tissue engineering applications. Our ongoing work aims at understanding the underlying principles of geometry-driven tissue growth, with a focus on the interactions between substrate geometry and mechanical forces.


M. Nikody J. Li D. Koper E.R. Balmayor P. Habibovic L. Moroni

Critical-sized bone defects remain challenging in the clinical setting. Autologous bone grafting remains preferred by clinicians. However, the use of autologous tissue is associated with donor-site morbidity and limited accessibility to the graft tissue. Advances in the development of synthetic bone substitutes focus on improving their osteoinductive properties. Whereas osteoinductivity has been demonstrated with ceramics, it is still a challenge in case of polymeric composites. One of the approaches to improve the regenerative properties of biomaterials, without changing their synthetic character, is the addition of inorganic ions with known osteogenic and angiogenic properties. We have previously reported that the use of a bioactive composite with high ceramic content composed of poly(ethyleneoxide terephthalate)/poly(butylene terephthalate) (1000PEOT70PBT30, PolyActive, PA) and 50% beta-tricalcium phosphate (β-TCP) with the addition of zinc in a form of a coating of the TCP particles can enhance the osteogenic differentiation of human mesenchymal stromal cells (hMSCs) (3). To further support the regenerative properties of these scaffolds, inorganic ions with known angiogenic properties, copper or cobalt, were added to the coating solution.

β-TCP particles were immersed in a zinc and copper or zinc and cobalt solution with a concentration of 15 or 45 mM. 3D porous scaffolds composed of 1000PEOT70PBT30 and pure or coated β-TCP were additively manufactured by 3D fibre deposition. The osteogenic and angiogenic properties of the fabricated scaffolds were tested in vitro through culture with hMSCs and human umbilical vein endothelial cells, respectively. The materials were further evaluated through ectopic implantation in an in vivo mini-pig model. The early expression of relevant osteogenic gene markers (collagen-1, osteocalcin) of hMSCs was upregulated in the presence of lower concentration of inorganic ions. Further analysis will focus on the evaluation of ectopic bone formation and vascularisation of these scaffolds after implantation in a mini-pig ectopic intramuscular model.


H. Isaksson M. Pierantoni I.S. Barreto M. Hammerman P. Eliasson

Achilles tendon mechanical properties depend on a complex hierarchical design, with collagen being the smallest load-bearing unit. At the nanoscale, collagen molecules are organized into fibrils, which at the microscale are assembled into fibers, followed by larger structures such as sub-tendons or fascicles. Degree of in vivo loading affects the collagen content, and organization and consequently the tissue's mechanical response. We aim to unravel how composition, structural organization, and mechanical response are affected by degree of in vivo loading at each length scale. The presentation will outline the results to date about to the use of high-resolution synchrotron-based tissue characterisation methods on several length scales in combination with in situ mechanical tests. We use a rat model, where the tendons are subjected to varying loading in vivo. To characterize the tissue microstructure, phase-contrast enhanced synchrotron micro-tomography is performed. The 3D fiber organization in fully loaded tendons is highly aligned, whereas the fibers in unloaded tendons are significantly more heterogeneously arranged and crimped. To characterize the collagen fibril response, Small Angle X-ray Scattering is performed. Two types of fibril organizations are found; a single population oriented towards the main load direction and two fibril subpopulations with clearly distinct orientations. Scattering during loading showed that the fibrils in unloaded tendons did not strain as much in fully loaded. In situ loading concurrently with high resolution synchrotron experiments show the complex tendon response to in situ load and its relation to in vivo loading and tendon hierarchical structure. Unloading seems to alter the organization of the fibrils and fibers, e.g. increased crimping and more pronounced sub-tendon twists.

Acknowledgements: Funding from Knut and Alice Wallenberg Foundation and European Research Council (101002516). Paul Scherrer Institut, Switzerland for beamtime at cSAXS and TOMCAT.


B. Baumann M. Danalache

Matrix metalloproteinase enzymes (MMPs) play a crucial role in the remodeling of articular cartilage, contributing also to osteoarthritis (OA) progression. The pericellular matrix (PCM) is a specialized space surrounding each chondrocyte, containing collagen type VI and perlecan. It acts as a transducer of biomechanical and biochemical signals for the chondrocyte. This study investigates the impact of MMP-2, -3, and -7 on the integrity and biomechanical characteristics of the PCM.

Human articular cartilage explants (n=10 patients, ethical-nr.:674/2016BO2) were incubated with activated MMP-2, -3, or -7 as well as combinations of these enzymes. The structural degradative effect on the PCM was assessed by immunolabelling of the PCM's main components: collagen type VI and perlecan. Biomechanical properties of the PCM in form of the elastic moduli (EM) were determined by means of atomic force microscopy (AFM), using a spherical cantilever tip (2.5µm).

MMPs disrupted the PCM-integrity, resulting in altered collagen type VI and perlecan structure and dispersed pericellular arrangement. A total of 3600 AFM-measurements revealed that incubation with single MMPs resulted in decreased PCM stiffness (p<0.001) when compared to the untreated group. The overall EM were reduced by ∼36% for all the 3 individual enzymes. The enzyme combinations altered the biomechanical properties at a comparable level (∼36%, p<0.001), except for MMP-2/-7 (p=0.202).

MMP-induced changes in the PCM composition have a significant impact on the biomechanical properties of the PCM, similar to those observed in early OA. Each individual MMP was shown to be highly capable of selectively degrading the PCM microenvironment. The combination of MMP-2 and -7 showed a lower potency in reducing the PCM stiffness, suggesting a possible interplay between the two enzymes. Our study showed that MMP-2, -3, and -7 play a direct role in the functional and structural remodeling of the PCM.

Acknowledgements: This work was supported by the Faculty of Medicine of the University of Tübingen (grant number.: 2650-0-0).


A.M. Dintheer P.K. Jaeger A.A. Hussien J.G. Snedeker

Extracellular matrix (ECM) mechanical cues guide healing in tendons. Yet, the molecular mechanisms orchestrating the healing processes remain elusive. Appropriate tissue tension is essential for tendon homeostasis and tissue health. By mapping the attainment of tensional homeostasis, we aim to understand how ECM tension regulates healing. We hypothesize that diseased tendon returns to homeostasis only after the cells reach a mechanically gated exit from wound healing.

We engineered a 3D mechano-culture system to create tendon-like constructs by embedding patient-derived tendon cells into a collagen I hydrogel. Casting the hydrogel between posts anchored in silicone allowed adjusting the post stiffness. Under this static mechanical stimulation, cells remodel the (unorganized) collagen representing wound healing mechanisms. We quantified tissue-level forces using post deflection measurements. Secreted ECM was visualized by metabolic labelling with non-canonical amino acids, click chemistry and confocal microscopy. We blocked cell-mediated actin-myosin contractility using a ROCK inhibitor (Y27632) to explore the involvement of the Rho/ROCK pathway in tension regulation.

Tissue tension forces reached the same homeostatic level at day 21 independent of post compliance (p = 0.9456). While minimal matrix was synthesized in early phases of tissue formation (d3-d5), cell-deposited ECM was present in later stages (d7-d9). More ECM was deposited by tendon constructs cultured on compliant (1Nm) compared to rigid posts (p = 0.0017). Matrix synthesized by constructs cultured on compliant posts was less aligned (greater fiber dispersion, p = 0.0021). ROCK inhibition significantly decreased tissue-level tensional forces (p < 0.0001).

Our results indicate that tendon cells balance matrix remodeling and synthesis during tissue repair to reach an intrinsically defined “mechanostat setpoint” guiding tension-mediated exit from wound healing towards homeostasis. We are identifying specific molecular mechanosensors governing tension-regulated healing in tendon and investigate the Rho/ROCK system as their possible downstream pathway.


E.V. Ely K.H. Collins K. Lenz S. Paradi W. Liedtke Y. Chen F. Guilak

Osteoarthritis (OA) is the leading cause of pain and disability worldwide and is characterized by the degenerative changes of articular cartilage. Joint loading is required for cartilage maintenance; however, hyper-physiologic loading is a risk factor for OA. Mechanosensitive ion channels Piezo1 and Piezo2 synergistically transduce hyper-physiologic compression of chondrocytes, leading to chondrocyte death and onset of OA. This injury response is inhibited by Piezo channel loss of function, however the mechanistic role of Piezo channels in vivo is unknown. We examined the hypothesis that deletion of Piezo in chondrocytes will protect mice from joint damage and pain-related behaviors following a surgical destabilization of the medial meniscus (DMM), investigating a key mechanistic and mechanobiological role of these channels in the pathogenesis of OA.

Aggrecan-Cre Piezo1 and Piezo1/2 knockout mice ((Agc)1-CREERT2;Piezo1fl/flPiezo2fl/fl) were generated and given a 5-day Tamoxifen regimen at 12-weeks of age (n=6–12/group/sex). Cre-negative mice served as controls. At 16-weeks, mice received DMM surgery on the left knee. 12-weeks following DMM prior to sacrifice, activity and hyperalgesia were measured using spontaneous running wheels and a small animal algometer. Structural changes in bone, cartilage, and synovium were characterized using microCT, histology, and Modified Mankin Score criteria.

Knockout of Piezo1/2 channels was chondroprotective in both sexes following DMM surgery as demonstrated by reduced Modified Mankin Score compared to control animals. Piezo1 KO was chondroprotective in only female mice, indicating a sexually dimorphic response. Piezo1 and Piezo1/2 KO was protective against pain in male mice, while females displayed no differences compared to controls. No changes were observed in bone morphology.

Chondrocyte-specific Piezo1/2 knockout protects the knee joint from structural damage, hyperalgesia and functional deficits in a surgical model of PTOA in male and female mice, illustrating the importance of Piezo channels in response to injury in vivo. Future work aims to interrogate potential sexually dimorphic responses to cartilage damage and investigating Piezo2 KO mice.


S. Ma A. Dubin L. Romero M. Loud A. Salazar S. Chu N. Klier S. Masri Y. Zhang Y. Wang A. Chesler K. Wilkinson V. Vásquez K. Marshall A. Patapoutian

Distal arthrogryposis (DA) is a collection of rare developmental disorders characterized by congenital joint contractures. Most arthrogryposis mutations are in muscle- and joint-related genes, and the anatomical defects originate cell-autonomously within the musculoskeletal tissues. However, gain-of-function (GOF) mutations in PIEZO2, a principal mechanosensor in somatosensation, cause DA subtype 5 via unknown mechanisms. We show that expression of a GOF PIEZO2 mutation in proprioceptive sensory neurons mainly innervating muscle spindles and tendons is sufficient to induce DA5-like phenotypes in mice. Overactive PIEZO2 causes anatomical defects via increased activity within the peripheral nervous system during postnatal development. Surprisingly, overactive PIEZO2 is likely to cause joint abnormalities via increased exocytosis from sensory neuron endings without involving motor circuitry. This reveals a role for somatosensory neurons: excessive mechanosensation within these neurons disrupts musculoskeletal development. We also present proof-of-concept that Botox injection or dietary treatment can counteract the effect of overactive PIEZO2 function to evade DA-like phenotypes in mice when applied during a developmental critical period. These approaches might have clinical applications. Beyond this, our findings call attention to the importance of considering sensory mechanotransduction when diagnosing and treating other musculoskeletal disorders.

Acknowledgements: Our work is supported by National Institutes of Health grant (R35 NS105067, R01 DE022358, R25 SC3GM127195, R25 GM07138, R01GM133845, intramural) and Howard Hughes Medical Institute.


A.E. Loiselle

During aging, tendons demonstrate substantial disruptions in homeostasis, leading to impairments in structure-function. Impaired tendon function contributes to substantial declines quality of life during aging. Aged tendons are more likely to undergo spontaneous rupture, and the healing response following injury is impaired in aged tendons. Thus, there is a need to develop strategies to maintain tendon homeostasis and healing capacity through the lifespan. Tendon cell density sharply declines by ∼12 months of age in mice, and this low cell density is retained in geriatric tendons. Our data suggests that this decline in cellularity initiates a degenerative cascade due to insufficient production of the extracellular matrix (ECM) components needed to maintain tendon homeostasis. Thus, preventing this decline in tendon cellularity has great potential for maintaining tendon health. Single cell RNA sequencing analysis identifies two changes in the aged tendon cell environment. First, aged tendons primarily lose tenocytes that are associated with ECM biosynthesis functions. Second, the tenocytes that remain in aged tendons have disruptions in proteostasis and an increased pro-inflammatory phenotype, with these changes collectively termed ‘programmatic skewing'. To determine which of these changes drives homeostatic disruption, we developed a model of tenocyte depletion in young animals. This model decreases tendon cellularity to that of an aged tendon, including decreased biosynthetic tenocyte function, while age-related programmatic skewing is absent. Loss of biosynthetic tenocyte function in young tendons was sufficient to induce homeostatic disruption comparable to natural aging, including deficits in ECM organization, composition, and material quality, suggesting loss biosynthetic tenocytes as an initiator of tendon degeneration. In contrast, our data suggest that programmatic skewing underpins impaired healing in aged tendons. Indeed, despite similar declines in the tenocyte environment, middle-aged and young-depleted tendons mount a physiological healing response characterized by robust ECM synthesis and remodeling, while aged tendons heal with insufficient ECM.


A. Vinhas M.T. Rodrigues A.I. Gonçalves M.E. Gomes

Common tendon injuries impair healing, leading to debilitation and an increased re-rupture risk. The impact of oxygen-sensing pathways on repair mechanisms, vital in regulating inflammation and fibrosis, remains unclear despite their relevance in tendon pathologies. Recent studies show that pulsed electromagnetic field (PEMF) reduce inflammation in human tendon cells (hTDCs) and in hypoxia-induced inflammation. We investigated the hypoxia's impact (1% and 2% oxygen tension) using magnetic cell sheet constructs (IL-1β-magCSs) primed with IL-1β. IL-1β-magCSs were exposed to low OT (1h, 4h,6h) in a hypoxic chamber. To confirm the role of PEMF (5Hz, 4mT, 50% duty cycle) on hypoxia modulation, IL-1β-magCSs, previously exposed to OT, were 1h-stimulated with PEMF. Our results show a significant increase in HIF- 1a and HIF-2a expression on IL-1β-magCSs after exposure to 2%-OT at all time points, compared to 1%- OT and normoxia. TNFa, IL-6, and IL-8 expression increased after 6 hours of 1%-OT exposure. PEMF stimulation of hypoxic IL-1β-magCSs led to decreased pro-inflammatory genes and increased anti-inflammatory (IL-4,IL-10) expression compared to unstimulated magCSs. IFN-g, TNF-α, and IL-6 release increased after 6 hours, regardless of %-OT, while IL-10 levels tended to rise after PEMF stimulation at 2%-OT. Also, NFkB expression was increased on IL-1β-magCSs exposed to 4 h and 6 h of 2%-OT, suggesting a link between NFkB and the production of pro-inflammatory factors. Moreover, PEMF stimulation showed a significantly decreased NFkB level in IL-1β-magCSs.

Overall, low OT enhances expression of hypoxia-associated genes and inflammatory markers in IL-1β-magCSs with the involvement of NFkB. PEMF modulates the response of magCSs, previously conditioned to hypoxia and to inflammatory triggers, favouring expression of anti-inflammatory genes and proteins, supporting PEMF impact in pro-regenerative tendon strategies.

Acknowledgements: ERC CoG MagTendon(No.772817), FCT under the Scientific Employment Stimulus-2020.01157.CEECIND. Thanks to Hospital da Prelada for providing tendon tissue samples (Portugal), and TERM

RES Hub (Norte-01-0145-FEDER-022190).


C. Lehner B. Benedetti H. Tempfer A. Traweger

Tendinopathy is a disease associated with pain and tendon degeneration, leading to a decreased range of motion and an increased risk of tendon rupture. The etiology of this frequent disease is still unknown. In other musculoskeletal tissues like cartilage and intervertebral discs, transient receptor potential channels (TRP- channels) were shown to play a major role in the progression of degeneration. Due to their responsiveness to a wide range of stimuli like temperature, pH, osmolarity and mechanical load, they are potentially relevant factors in tendon degeneration as well. We therefore hypothesize that TRP- channels are expressed in tendon cells and respond to degeneration inducing stimuli.

By immunohistochemistry, qRT-PCR and western blot analyses, we found three TRP channel members, belonging to the vanilloid (TRPV), and ankyrin (TRPA) subfamily, respectively, to be expressed in healthy human tendon tissue as well as in rodent tendon, with expression being located to cells within the dense tendon proper, as well as to endotenon resident cells. In vitro-inflammatory and ex vivo-mechanical stimulation led to a significant upregulation of TRPA1 expression in tendon cells, which correlates well with the fact that TRPA1 is considered as mechanosensitive channel being sensitized by inflammatory mediators.

This is the first description of TRP- channels in human and rodent tendon. As these channels are pharmacologically targetable by both agonists and antagonists, they may represent a promising target for novel treatments of tendinopathy.


N. Marr D.E. Zamboulis R.E. Beaumont Z.J. Tatarczyk R. Meeson C.T. Thorpe

Tendon injuries occur frequently in athletes and the general population, with inferior healing leading to deposition of fibrotic scar tissue. New treatments are essential to limit fibrosis and enable tendon regeneration post-injury. In this study, we tested the hypothesis that rapamycin improves tendon repair and limits fibrosis by inhibiting the mTOR pathway.

The left hindlimb of female adult Wistar rats was injured by needle puncture and animals were either given daily injections of rapamycin (2mg/kg) or vehicle. Animals were euthanized 1 week or 3 weeks post-injury (n=6/group). Left and right Achilles tendons were harvested, with the right limbs acting as controls. Tendon sections were stained with haematoxylin & eosin, and scored by 2 blinded scorers, assessing alterations in cellularity, cell morphology, vascularity, extracellular matrix (ECM) organization and peritendinous fibrosis. Immunohistochemistry was performed for the tendon pan-vascular marker CD146 and the autophagy marker LC3.

Injury resulted in significantly altered ECM organization, cell morphology and cellularity in both rapamycin and vehicle-treated groups, but no alterations in vascularity compared to uninjured tendons. Rapamycin had a limited effect on tendon repair, with a significant reduction in peritendinous fibrosis 3 weeks after injury (p=0.028) but no change in cell morphology, cellularity or ECM organization compared to vehicle treated tendons at either 1 week or 3 weeks post injury. CD146 labelling was increased at the site of injury, but there was no apparent difference in CD146 or LC3 labelling in rapamycin and vehicle treated tendons.

The decrease in peritendinous fibrosis post-injury observed in rapamycin treated tendons indicates rapamycin as a potential therapy for tendon adhesions. However, the lack of improvement of other morphological parameters in response to rapamycin treatment indicates that rapamycin is not an effective therapy for injuries to the tendon core.

Acknowledgements: This study was funded by Versus Arthritis (22607)


D.E. Zamboulis F.S.S. Ali C.T. Thorpe

Energy storing tendons such as the human Achilles and equine superficial digital flexor tendon (SDFT) are prone to age-related injury. Tendons have poor healing capacity and a lack of effective treatments can lead to ongoing pain, reduced function and re-injury. It is therefore important to identify the mechanisms underpinning age-related tendinous changes in order to develop more effective treatments. Our recent single cell sequencing data has shown that tendon cell populations have extensive heterogeneity and cells housed in the tendon interfascicular matrix (IFM) are preferentially affected by ageing. There is, however, a lack of established surface markers for cell populations in tendon, limiting the capacity to isolate distinct cell populations and study their contribution to age-related tendon degeneration. Here, we investigate the presence of the cell surface proteins MET proto-oncogene (MET), integrin subunit alpha 10 (ITGA10), fibroblast activation protein alpha (FAP) and platelet derived growth factor receptor alpha (PDGFRA) in the equine SDFT cell populations and their co-localisation with known markers.

Using Western blot we validated the specificity of selected antibodies in equine tissue before performing immunohistochemistry to establish the location of the respective proteins in the SDFT. We subsequently used double labelling immunofluorescence with the established mural cell marker desmin (DES) to distinguish between tenocyte and mural cell populations.

In situ, MET, ITGA10, and FAP presence was found in cells throughout the tendon whereas PDGFRA was present in cells within the IFM. Double labelling immunofluorescence with the mural cell marker DES showed lack of co-localisation between PDGFRA and DES suggesting PDGFRA is labelling an IFM cell population distinct from those associated with blood vessels.

PDGFRA is a promising target for the specific cell sorting of IFM-localised tenocytes, enabling their isolation and subsequent characterisation.

Acknowledgments: The authors acknowledge the Biotechnology and Biological Sciences Research Council (BB/W007282/1) for funding this work.


B. Gueorguiev P. Varga

Intramedullary nails (IMNs) are the current gold standard for treatment of long bone diaphyseal and selected metaphyseal fractures. Their design has undergone many revisions to improve fixation techniques, conform to the bone shape with appropriate anatomic fit, reduce operative time and radiation exposure, and extend the indication of the same implant for treatment of different fracture types with minimal soft tissue irritation.

The IMNs are made or either titanium alloy or stainless steel and work as load-sharing internal splints along the long bone, usually accommodating locking elements – screws and blades, often featuring angular stability and offering different configurations for multiplanar fixation – to secure secondary fracture healing with callus formation in a relative-stability environment. Bone cement augmentation of the locking elements can modulate the construct stiffness, increase the surface area at the bone-implant interface, and prevent cut-through of the locking elements.

The functional requirements of IMNs are related to maintaining fracture reduction in terms of length, alignment and rotation to enhance fracture healing. The load distribution during patient's activities is along the entire bone-nail interface, with nail length and anatomic fit being important factors to avoid stress risers.


H.S. Ponniah T. Edwards J. Lex R. Davidson M. Al-Zubaidy I. Afzal R. Field A. Liddle J. Cobb K. Logishetty

Anterior approach total hip arthroplasty (AA-THA) has a steep learning curve, with higher complication rates in initial cases. Proper surgical case selection during the learning curve can reduce early risk. This study aims to identify patient and radiographic factors associated with AA-THA difficulty using Machine Learning (ML).

Consecutive primary AA-THA patients from two centres, operated by two expert surgeons, were enrolled (excluding patients with prior hip surgery and first 100 cases per surgeon). K- means prototype clustering – an unsupervised ML algorithm – was used with two variables - operative duration and surgical complications within 6 weeks - to cluster operations into difficult or standard groups.

Radiographic measurements (neck shaft angle, offset, LCEA, inter-teardrop distance, Tonnis grade) were measured by two independent observers. These factors, alongside patient factors (BMI, age, sex, laterality) were employed in a multivariate logistic regression analysis and used for k-means clustering. Significant continuous variables were investigated for predictive accuracy using Receiver Operator Characteristics (ROC).

Out of 328 THAs analyzed, 130 (40%) were classified as difficult and 198 (60%) as standard. Difficult group had a mean operative time of 106mins (range 99–116) with 2 complications, while standard group had a mean operative time of 77mins (range 69–86) with 0 complications. Decreasing inter-teardrop distance (odds ratio [OR] 0.97, 95% confidence interval [CI] 0.95–0.99, p = 0.03) and right-sided operations (OR 1.73, 95% CI 1.10–2.72, p = 0.02) were associated with operative difficulty. However, ROC analysis showed poor predictive accuracy for these factors alone, with area under the curve of 0.56. Inter-observer reliability was reported as excellent (ICC >0.7).

Right-sided hips (for right-hand dominant surgeons) and decreasing inter-teardrop distance were associated with case difficulty in AA-THA. These data could guide case selection during the learning phase. A larger dataset with more complications may reveal further factors.


M. Rasouligandomani F. Chemorion M.-A. Bisotti J. Noailly M.A. González Ballester

Adult Spine Deformity (ASD) is a degenerative condition of the adult spine leading to altered spine curvatures and mechanical balance. Computational approaches, like Finite Element (FE) Models have been proposed to explore the etiology or the treatment of ASD, through biomechanical simulations. However, while the personalization of the models is a cornerstone, personalized FE models are cumbersome to generate. To cover this need, we share a virtual cohort of 16807 thoracolumbar spine FE models with different spine morphologies, presented in an online user-interface platform (SpineView). To generate these models, EOS images are used, and 3D surface spine models are reconstructed. Then, a Statistical Shape Model (SSM), is built, to further adapt a FE structured mesh template for both the bone and the soft tissues of the spine, through mesh morphing. Eventually, the SSM deformation fields allow the personalization of the mean structured FE model, leading to generate FE meshes of thoracolumbar spines with different morphologies. Models can be selectively viewed and downloaded through SpineView, according to personalized user requests of specific morphologies characterized by the geometrical parameters: Pelvic Incidence; Pelvic Tilt; Sacral Slope; Lumbar Lordosis; Global Tilt; Cobb Angle; and GAP score. Data quality is assessed using visual aids, correlation analyses, heatmaps, network graphs, Anova and t-tests, and kernel density plots to compare spinopelvic parameter distributions and identify similarities and differences. Mesh quality and ranges of motion have been assessed to evaluate the quality of the FE models. This functional repository is unique to generate virtual patient cohorts in ASD.

Acknowledgements: European Commission (MSCA-TN-ETN-2020-Disc4All-955735, ERC-2021-CoG-O-Health-101044828)


D. Mischler M. Windolf B. Gueorguiev P. Varga

Osteosynthesis aims to maintain fracture reduction until bone healing occurs, which is not achieved in case of mechanical fixation failure. One form of failure is plastic plate bending due to overloading, occurring in up to 17% of midshaft fracture cases and often necessitating reoperation. This study aimed to replicate in-vivo conditions in a cadaveric experiment and to validate a finite element (FE) simulation to predict plastic plate bending.

Six cadaveric bones were used to replicate an established ovine tibial osteotomy model with locking plates in-vitro with two implant materials (titanium, steel) and three fracture gap sizes (30, 60, 80 mm). The constructs were tested monotonically until plastic plate deformation under axial compression. Specimen-specific FE models were created from CT images. Implant material properties were determined using uniaxial tensile testing of dog bone shaped samples. The experimental tests were replicated in the simulations. Stiffness, yield, and maximum loads were compared between the experiment and FE models.

Implant material properties (Young's modulus and yield stress) for steel and titanium were 184 GPa and 875 MPa, and 105 GPa and 761 MPa, respectively. Yield and maximum loads of constructs ranged between 469–491 N and 652–683 N, and 759–995 N and 1252–1600 N for steel and titanium fixations, respectively. FE models accurately and quantitatively correctly predicted experimental results for stiffness (R2=0.96), yield (R2=0.97), and ultimate load (R2=0.97).

FE simulations accurately predicted plastic plate bending in osteosynthesis constructs. Construct behavior was predominantly driven by the implant itself, highlighting the importance of modelling correct material properties of metal. The validated FE models could predict subject-specific load bearing capacity of osteosyntheses in vivo in preclinical or clinical studies.

Acknowledgements: This study was supported by the AO Foundation via the AOTRAUMA Network (Grant No.: AR2021_03).


A. Vautrin J. Aw E. Attenborough P. Varga

Although 3D-printed porous dental implants may possess improved osseointegration potential, they must exhibit appropriate fatigue strength. Finite element analysis (FEA) has the potential to predict the fatigue life of implants and accelerate their development. This work aimed at developing and validating an FEA-based tool to predict the fatigue behavior of porous dental implants.

Test samples mimicking dental implants were designed as 4.5 mm-diameter cylinders with a fully porous section around bone level. Three porosity levels (50%, 60% and 70%) and two unit cell types (Schwarz Primitive (SP) and Schwarz W (SW)) were combined to generate six designs that were split between calibration (60SP, 70SP, 60SW, 70SW) and validation (50SP, 50SW) sets.

Twenty-eight samples per design were additively manufactured from titanium powder (Ti6Al4V). The samples were tested under bending compression loading (ISO 14801) monotonically (N=4/design) to determine ultimate load (Fult) (Instron 5866) and cyclically at six load levels between 50% and 10% of Fult (N=4/design/load level) (DYNA5dent). Failure force results were fitted to F/Fult = a(Nf)b (Eq1) with Nf being the number of cycles to failure, to identify parameters a and b. The endurance limit (Fe) was evaluated at Nf = 5M cycles. Finite element models were built to predict the yield load (Fyield) of each design. Combining a linear correlation between FEA-based Fyield and experimental Fult with equation Eq1 enabled FEA-based prediction of Fe.

For all designs, Fe was comprised between 10% (all four samples surviving) and 15% (at least one failure) of Fult. The FEA-based tool predicted Fe values of 11.7% and 12.0% of Fult for the validation sets of 50SP and 50SW, respectively. Thus, the developed FEA-based workflow could accurately predict endurance limit for different implant designs and therefore could be used in future to aid the development of novel porous implants.

Acknowledgements: This study was funded by EU's Horizon 2020 grant No. 953128 (I-SMarD). We gratefully acknowledge the expert advice of Prof. Philippe Zysset.


Y.P. Özer D. Karaduman Y. Karanfil E. Çiftçi C. Balci B.B. Doğu M.G. Halil M. Cankurtaran F. Korkusuz

Osteoarthritis (OA) of the knee joint is a complex peripheral joint disorder with multiple risk factors. We aimed to examine the relationship between the grade of knee OA and anterior thigh length (ATL).

A total of 64 geriatric patients who had no total hip or knee replacement with a BMI of ≥30 were evaluated. Patients' OA severity was determined by two independent experts from bilateral standing knee radiographs according to the Kellgren-Lawrence (KL) grade. Joint cartilage structure was assessed using ultrasonography (US). The ATL, the gastrocnemius medialis (GC), the rectus femoris (RF) and the rectus abdominis (RA) skeletal muscle thicknesses as well as the RF cross-sectional area (CSA) were measured with US. Sarcopenia was diagnosed using the handgrip strength (HGS), 5× sit-to-stand test (5xSST) and bioelectrical impedance analysis.

The median (IQR) age of participants was 72 (65–88) years. Seventy-one per cent of the patients (n=46) were female. They were divided into the sarcopenic obese (31.3 %) and the non-sarcopenic obese (68.8%) groups. KL grade of all patients correlated negatively with the ATL (mm) and the thickness of GC (mm) (r= -0,517, p<0.001 and r= -0.456, p<0.001, respectively). In the sarcopenic obese and the non-sarcopenic obese groups, KL grade of the all patients was negatively correlated with ATL (mm) and thickness of GC (mm) (r= -0,986, p<0.001; r= -0.456, p=0.05 and r= -0,812, p=0.002; r= −0,427, p=0.006). KL grade negatively correlated with the RF thickness in the sarcopenic obese group (r= -0,928, p=0.008).

In conclusion, OA risk may decrease as the lower extremity skeletal muscle mass increases.

Acknowledgments: Feza Korkusuz MD is a member of the Turkish Academy of Sciences (TÜBA).


M. Segarra-Queralt M. Galofré L. Tio J. Monfort J.C. Monllau G. Piella J. Noailly

Knee osteoarthritis (KOA) diagnosis is based on symptoms, assessed through questionnaires such as the WOMAC. However, the inconsistency of pain recording and the discrepancy between joint phenotype and symptoms highlight the need for objective biomarkers in KOA diagnosis. To this end, we study relationships among clinical and molecular data in a cohort of women (n=51) with Kellgren-Lawrence grade 2–3 KOA through Support Vector Machine (SVM) and a regulation network model (RNM). Clinical descriptors (i.e., pain catastrophism (CA); depression (DE); functionality (FU); joint pain (JP); rigidity (RI); sensitization (SE); synovitis (SY)) are used to classify patients. A Youden's test is performed for each classifier to determine optimal binarization thresholds for the descriptors. Thresholds are tested against patient stratification according to baseline WOMAC data from the Osteoarthritis Initiative, and the mean accuracy is 0.97. For our cohort, the data used as SVM inputs are KOA descriptors, synovial fluid (SL) proteomic measurements (n=25), and transcription factors (TF) activation obtained from RNM [2] stimulated with the SL measurements. The relative weights after classification reflect input importance. The performance of each classifier is evaluated through AUC-ROC analysis. The best classifier with clinical data is CA (AUC = 0.9), highly influenced by FU and SE, suggesting that kinesophobia is involved in pain perception. With SL input, leptin strongly influences every classifier, suggesting the importance of low-grade inflammation. When TF are used, the mean AUC is limited to 0.608, which can be related to the pleomorphic behaviour of osteoarthritic chondrocytes. Nevertheless, FU has an AUC of 0.7 with strong importance of FOXO downregulation. Though larger and longitudinal cohorts are needed, this unique combination of SVM and RNM shall help to map objectively KOA descriptors.

Acknowledgements: Catalan & Spanish governments 2020FI_b00680; STRATO-PID2021126469ob-C21-2, European Commission (MSCA-TN-ETN-2020-Disc4All-955735, ERC-2021-CoG-O-Health-101044828). ICREA Academia.


S. Taheri T. Yoshida K. O. Böker R.H. Foerster L. Jochim A.L. Flux B. Grosskopf T. Hawellek W. Lehmann A.F. Schilling

Articular cartilage (AC) and subchondral bone (SB) are intimately intertwined, forming a complex unit called the AC-SB interface. Our recent studies have shown that cartilage and bone marrow are connected by a three-dimensional network of microchannels (i.e. cartilage-bone marrow microchannel connector; CMMC), which differ microarchitecturally in number, size and morphology depending on the maturation stage of the bone and the region of the joint. However, the pathological significance of CMMC is largely unknown. Here, we quantitatively assessed how CMMC microarchitecture relates to cartilage condition and regional differences in early idiopathic osteoarthritis (OA).

Two groups of cadaveric female human femoral heads (intact cartilage vs early cartilage lesions) were identified and biopsy-based high-resolution micro-CT imaging was used. Subchondral bone (SB) thickness, CMMC number, maximum and minimum CMMC size, and CMMC morphology were quantified and compared between the two groups. The effect of joint region and cartilage condition on each dependent variable was examined.

The number and morphology of CMMCs were influenced by the region of the joint, but not by the cartilage condition. On the other hand, the minimum and maximum CMMC size was modified by both joint location and cartilage condition. The smallest CMMCs were consistently found in the load bearing region (LBR) of the joint. Compared to healthy subjects, the size of the microchannels was increased in early OA, most notably in the non-load bearing region (NLBR) and the peripheral rim (PR) of the femoral head. In addition, subchondral bone thinning was observed in early OA as a localized event associated with areas of partial chondral defect.

Our data suggest an enlargement of the SB microchannel network and a collective structural deterioration of the SB in early idiopathic OA.


S. Zwingenberger

Spinal diseases such as unstable fractures, infections, primary or secondary tumors or deformities require surgical stabilization with implants. The long-term success of this treatment is only ensured by a solid bony fusion. The size of the bony defect, the often poor bone quality and metabolic diseases increase the risk of non-union and make the case a great burden for the patient and a challenge for the surgeon. The goal of spinal fusion can only be achieved if the implants used offer sufficient mechanical stability and the local biological regeneration potential is large enough to form sufficient bone. The lecture will present challenging clinical cases. In addition, implant materials and new surgical techniques are discussed. Local therapeutic effects are achieved through the release of osteopromotive or anti-resorbtive drugs, growth factors and antibiotics. By influencing biological pathways, basic orthopedic research has strong potential to further positively change future spinal surgery.


M. Feng S. Dai J. Ni G. Mao X. Dang Z. Shi

Varus malalignment increases the susceptibility of cartilage to mechanical overloading, which stimulates catabolic metabolism to break down the extracellular matrix and lead to osteoarthritis (OA). The altered mechanical axis from the hip, knee to ankle leads to knee joint pain and ensuing cartilage wear and deterioration, which impact millions of the aged population. Stabilization of the remaining damaged cartilage, and prevention of further deterioration, could provide immense clinical utility and prolong joint function. Our previous work showed that high tibial osteotomy (HTO) could shift the mechanical stress from an imbalanced status to a neutral alignment. However, the underlying mechanisms of endogenous cartilage stabilization after HTO remain unclear. We hypothesize that cartilage-resident mesenchymal stem cells (MSCs) dampen damaged cartilage injury and promote endogenous repair in a varus malaligned knee. The goal of this study is to further examine whether HTO-mediated off-loading would affect human cartilage-resident MSCs' anabolic and catabolic metabolism. This study was approved by IACUC at Xi'an Jiaotong University. Patients with medial compartment OA (52.75±6.85 yrs, left knee 18, right knee 20) underwent open-wedge HTO by the same surgeons at one single academic sports medicine center. Clinical data was documented by the Epic HIS between the dates of April 2019 and April 2022 and radiographic images were collected with a minimum of 12 months of follow-up. Medial compartment OA with/without medial meniscus injury patients with unilateral Kellgren /Lawrence grade 3–4 was confirmed by X-ray. All incisions of the lower extremity healed well after the HTO operation without incision infection. Joint space width (JSW) was measured by uploading to ImageJ software. The Knee injury and Osteoarthritis Outcome Score (KOOS) toolkit was applied to assess the pain level. Outerbridge scores were obtained from a second-look arthroscopic examination. RNA was extracted to quantify catabolic targets and pro-inflammatory genes (QiaGen). Student's t test for two group comparisons and ANOVA analysis for differences between more than 2 groups were utilized. To understand the role of mechanical loading-induced cartilage repair, we measured the serial changes of joint space width (JSW) after HTO for assessing the state of the cartilage stabilization. Our data showed that HTO increased the JSW, decreased the VAS score and improved the KOOS score significantly. We further scored cartilage lesion severity using the Outerbridge classification under a second-look arthroscopic examination while removing the HTO plate. It showed the cartilage lesion area decreased significantly, the full thickness of cartilage increased and mechanical strength was better compared to the pre-HTO baseline. HTO dampened medial tibiofemoral cartilage degeneration and accelerate cartilage repair from Outerbridge grade 2 to 3 to Outerbridge 0 to 1 compared to untreated varus OA. It suggested that physical loading was involved in HTO-induced cartilage regeneration. Given that HTO surgery increases joint space width and creates a physical loading environment, we hypothesize that HTO could increase cartilage composition and collagen accumulation. Consistent with our observation, a group of cartilage-resident MSCs was identified. Our data further showed decreased expression of RUNX2, COL10 and increased SOX9 in MSCs at the RNA level, indicating that catabolic activities were halted during mechanical off-loading. To understand the role of cartilage-resident MSCs in cartilage repair in a biophysical environment, we investigated the differentiation potential of MSCs under 3-dimensional mechanical loading conditions. The physical loading inhibited catabolic markers (IL-1 and IL-6) and increased anabolic markers (SOX9, COL2).

Knee-preserved HTO intervention alleviates varus malalignment-related knee joint pain, improves daily and recreation function, and repairs degenerated cartilage of medial compartment OA. The off-loading effect of HTO may allow the mechanoregulation of cartilage repair through the differentiation of endogenous cartilage-derived MSCs.


I. Vargel M.F. Açil S.A. Tuncel N. Baysal I. Hartuç H. Okur F. Korkusuz

Deriving autologous mesenchymal stem cells (MSCs) from adipose tissues without using enzymes requires sophisticated biomedical instruments. Applied pressure on tissues and cells are adjusted manually although centrifugation and filtration systems are frequently used. The number of derived MSCs therefore could differ between instruments. We compared the number of MSCs obtained from four commercially available devices and our newly designed and produced instrument (A2, B3, L3, M2 and T3). Three-hundred mL of adipose tissue was obtained from a female patient undergoing liposuction using the transillumination solution. Obtained tissue was equally distributed to each device and handled according to the producers' guides. After handling, 3 mL stromal vascular fraction (SVF) was obtained from each device. Freshly isolated SVF was characterized using multi-color flow cytometry (Navios Flow Cytometer, Beckman Coulter, USA). Cell surface antigens were chosen according to IFATS and ISCT. CD31-FITC, CD34-PC5,5, CD73-PE, CD90-PB and CD45-A750 (Backman Coulter, USA) fluorochrome-labeled monoclonal antibodies were assessed. Markers were combined with ViaKrome (Beckman Coulter, USA) to determine cell viability. At least 105 cells were acquired from each sample. A software (Navios EX, Beckman Coulter, USA) was used to create dot plots and to calculate the cell composition percentages. The data was analyzed in the Kaluza 2.1 software package (Beckman Coulter, USA). Graphs were prepared in GraphPad Prism. CD105 PC7/CD31 FITC cell percentages were 23,9%, 13,5%, 24,6%, 11,4% and 28,8% for the A2, B3, L3, M2 and T3 devices, respectively. We conclude that the isolated MSC percentage ranged from 11,4% to 28,8% between devices. The number of MSCs in SVF are key determinants of success in orthobiological treatments. Developing a device should focus on increasing the number of MSCs in the SVF while preserving its metabolic activity.

Acknowledgments: Scientific and Technological Research Council of Türkiye (TÜBİTAK)- Technology and Innovation Funding Program Directorate (TEYDEB) funded this project (#321893). Servet Kürümoğlu and Bariscan Önder of Disposet Ltd., Ankara, Türkiye (www.disposet.com) contributed to the industrial design and research studies. Ali Tuncel and Feza Korkusuz are members of the Turkish Academy of Sciences (TÜBA). Nilsu Baysal was funded by the STAR Program of TÜBITAK Grant # 3210893.


M.-S. Kim K.-I. Kim,

There is still no consensus on which concentration of mesenchymal stem cells (MSCs) to use for promoting fracture healing in a rat model of long bone fracture.

To assess the optimal concentration of MSCs for promoting fracture healing in a rat model.

Wistar rats were divided into four groups according to MSC concentrations: Normal saline (C), 2.5 × 106 (L), 5.0 × 106 (M), and 10.0 × 106 (H) groups. The MSCs were injected directly into the fracture site. The rats were sacrificed at 2 and 6 자 post-fracture. New bone formation [bone volume (BV) and percentage BV (PBV)] was evaluated using micro-computed tomography (CT). Histological analysis was performed to evaluate fracture healing score. The protein expression of factors related to MSC migration [stromal cell-derived factor 1 (SDF-1), transforming growth factor-beta 1 (TGF-β1)] and angiogenesis [vascular endothelial growth factor (VEGF)] was evaluated using western blot analysis. The expression of cytokines associated with osteogenesis [bone morphogenetic protein-2 (BMP-2), TGF-β1 and VEGF] was evaluated using real-time polymerase chain reaction.

Micro-CT showed that BV and PBV was significantly increased in groups M and H compared to that in group C at 6 wk post-fracture (P = 0.040, P = 0.009; P = 0.004, P = 0.001, respectively). Significantly more cartilaginous tissue and immature bone were formed in groups M and H than in group C at 2 and 6 wk post-fracture (P = 0.018, P = 0.010; P = 0.032, P = 0.050, respectively). At 2 wk post fracture, SDF-1, TGF-β1 and VEGF expression were significantly higher in groups M and H than in group L (P = 0.031, P = 0.014; P < 0.001, P < 0.001; P = 0.025, P < 0.001, respectively). BMP-2 and VEGF expression were significantly higher in groups M and H than in group C at 6 wk postfracture (P = 0.037, P = 0.038; P = 0.021, P = 0.010). Compared to group L, TGF-β1 expression was significantly higher in groups H (P = 0.016). There were no significant differences in expression levels of chemokines related to MSC migration, angiogenesis and cytokines associated with osteogenesis between M and H groups at 2 and 6 wk post-fracture.

The administration of at least 5.0 × 106 MSCs was optimal to promote fracture healing in a rat model of long bone fractures.


Y. Gao X. Wu Z. Zhang J. Xu

Stem cell therapy is an effective means to address the repair of large segmental bone defects. However, the intense inflammatory response triggered by the implants severely impairs stem cell differentiation and tissue regeneration. High-dose transforming growth factor β1 (TGF-β1), the most locally expressed cytokine in implants, inhibits osteogenic differentiation of bone marrow mesenchymal stem cells (BMSCs) and promotes tissue fibrosis, severely compromising the efficacy of stem cell therapy. Small molecule inhibitors of TGF-β1 can be used to ameliorate the osteogenic disorders caused by high concentrations of TGF-β1, but systemic inhibition of TGF-β1 function will cause strong adverse effects. How to find safe and reliable molecular targets to antagonize TGF-β1 remains to be elucidated. Orphan nuclear receptor Nr4a1, an endogenous inhibitory molecule of TGF-β1, suppresses tissue fibrosis, but its role in BMSC osteogenesis is unclear. We found that TGF-β1 inhibited Nr4a1 expression through HDAC4. Overexpression of Nr4a1 in BMSCs reversed osteogenic differentiation inhibited by high levels of TGF- β1. Mechanistically, RNA sequencing showed that Nr4a1 activated the ECM-receptor interaction and Hippo signaling pathway, which in turn promoted BMSC osteogenesis. In bone defect repair and fracture healing models, transplantation of Nr4a1-overexpressing BMSCs into C57BL/6J mice or treatment with the Nr4a1 agonist Csn-B significantly ameliorated inflammation-induced bone regeneration disorders. In summary, our findings confirm the endogenous inhibitory effect of Nr4a1 on TGF- β1 and uncover the effectiveness of Nr4a1 agonists as a therapeutic tool to improve bone regeneration, which provides a new solution strategy for the treatment of clinical bone defects and inflammatory skeletal diseases.


Mario Gimona

Nanovesicle-based therapy is increasingly being pursued as a safe, cell-free strategy to combat various immunological, musculoskeletal and neurodegenerative diseases. Small secreted extracellular vesicles (sEVs) obtained from multipotent mesenchymal stromal cells (MSCs) are of particular interest for therapeutic use since they convey anti-inflammatory, anti-scarring and neuroprotective activities to the recipient cells. Cell-derived vesicles (CDVs) produced by a proprietary extrusion process are surrounded by a lipid bilayer membrane with correct membrane topology, display biological activities similar to MSC-derived EVs and may find specific application for organ-targeted drug delivery systems. Translation of nanovesicle-based therapeutics into clinical application requires quantitative and reproducible analysis of bioactivity and stability, and the potential for GMP-compliant manufacturing. Manufacturing and regulatory considerations as well as preclinical models to support clinical translation will be discussed.


A.L. Graça M.T. Rodrigues R.M.A. Domingues M.E. Gomes M. Gomez-Florit

Macrophages play a critical role in innate immunity by promoting or inhibiting tissue inflammation and repair. Classically, macrophages can differentiate into either pro-inflammatory (M1) or pro-reparative (M2) phenotypes in response to various stimuli. Therefore, this study aimed to address how extracellular vesicles (EVs) derived from polarized macrophages can affect the inflammatory response of tendon cells.

For that purpose, human THP-1 cells were stimulated with lipopolysaccharide (LPS), and interleukins -4 and -13 (IL- 4, IL-13), to induce macrophages polarization into M1, M2, and hybrid M1/M2 phenotypes. Subsequently, the EVs were isolated from the culture medium by ultracentrifugation. The impact of these nanovesicles on the inflammation and injury scenarios of human tendon-derived cells (hTDCs), which had previously been stimulated with interleukin- 1 beta (IL-1ß) to mimic an inflammatory scenario, was assessed.

We were able to isolate three different nanovesicles populations, showing the typical shape, size and surface markers of EVs. By extensively analyzing the proteomic expression profiles of M1, M2, and M1/M2, distinct proteins that were upregulated in each type of macrophage-derived EVs were identified. Notably, most of the detected pro- inflammatory cytokines and chemokines had higher expression levels in M1-derived EVs and were mostly absent in M2-derived EVs. Hence, by acting as a biological cue, we observed that M2 macrophage-derived EVs increased the expression of the tendon-related marker tenomodulin (TNMD) and tended to reduce the presence of pro-inflammatory markers in hTDCs. Overall, these preliminary results show that EVs derived from polarized macrophages might be a potential tool to modulate the immune system responses becoming a valuable asset in the tendon repair and regeneration fields worthy to be further explored.


Maria Antònia Forteza-Genestra Miquel Antich-Rosselló Carmen Ráez-Meseguer Guillem Ramis-Munar Anna Tomàs Sangenís Javier Calvo Antoni Gayà Marta Monjo Joana Maria Ramis

Osteoarthritis (OA) is a degenerative disease that lacks regenerative treatment options. Current research focuses on mesenchymal stem cells (MSCs) and Platelet-Rich Plasma (PRP) as regenerative therapies, but extracellular vesicles (EVs) have shown to be more advantageous. This study compares the regenerative potential of human umbilical cord MSC-derived EVs (cEVs) and platelet-derived EVs (pEVs) in ex vivo and in vivo OA models.

In the ex vivo study, OA conditions were induced in human cartilage explants, which were then treated either with pEVs or cEVs. Results showed a higher content of DNA and collagen in the pEVs group compared to control and cEVs groups, suggesting that pEVs could be a potential alternative to cEVs.

In the in vivo study, an OA model was established in the knee joints of rats through MIA (monoiodoacetate) injection and then treated either with pEVs or cEVs. Results showed that pEVs-treated knee joints had better subchondral bone integrity and greater OA reversion, particularly in female rats, indicating that pEVs are a viable regeneration treatment for OA and outperform cEVs in terms of efficacy.

Overall, the study demonstrates the potential of EVs as a regenerative treatment for OA, with pEVs showing promising results in both ex vivo and in vivo models. The use of pEVs in clinical practice could provide a faster path to translation due to the established use of platelet concentrates in therapeutics. However, further studies are needed to fully evaluate the potential of pEVs for OA treatment and to elucidate the mechanisms behind their regenerative effects.

Acknowledgments: The authors thank Dr Fernando Hierro (UIB) for their technical contribution with TEM, Mª Trinidad García (UIB) for the access to radioactivity facilities, Aina Arbós (IUNICS) for her contribution in the histology staining, María Tortosa (IdISBa) for her assistance with the animal care and ADEMA School of Dentistry for the access to the cone beam computed tomography (CBCT).

Funding: This research was funded by Instituto de Salud Carlos III, Ministerio de Economía y Competitividad, co-funded by the ESF European Social Fund and the ERDF European Regional Development Fund (MS16/00124; CP16/00124), PROGRAMA JUNIOR del proyecto TALENT PLUS, construyendo SALUD, generando VALOR (JUNIOR01/18), financed by the sustainable tourism tax of the Balearic Islands; the Direcció General d'Investigació and Conselleria d'Investigació, Govern Balear (FPI/2046/2017); the Mecanisme de Recuperació i Resiliència, intended to execute research projects of «Noves polítiques públiques per a un mercat de treball dinàmic, resilient i inclusiu», collected in Pla de Recuperació, Transformació i Resiliència, financed by European Union-Next Generation EU and driven by SOIB and Conselleria de Fons Europeus, Universitat i Cultura i la Conselleria de Model Econòmic, Turisme i Treball (NG0421) and the grant SYN20/03 from IdISBa.


M.E.F. Palamà C. Gorgun G. Shaw M. Mauphy C. Gentili

Mesenchymal stem cells (MSCs) have been studied for the treatment of Osteoarthritis (OA), a potential mechanism of MSC therapies has been attributed to paracrine activity, in which extracellular vesicles (EVs) may play a major role. It is suggested that MSCs from younger donor compete with adult MSC in their EV production capabilities. Therefore, MSCs generated from induced pluripotent mesenchymal stem cells (iMSC) appear to provide a promising source. In this study, MSCs and iMSC during long term-expansion using a serum free clinical grade condition, were characterized for surface expression pattern, proliferation and differentiation capacity, and senescence rate. Culture media were collected continuously during cell expansion, and EVs were isolated. Nanoparticle tracking analysis (NTA), transmission electron microscopy, western blots, and flow cytometry were used to identify EVs. We evaluated the biological effects of MSC and iMSC-derived EVs on human chondrocytes treated with IL-1α, to mimic the OA environment.

In both cell types, from early to late passages, the amount of EVs detected by NTA increased significantly, EVs collected during cells expansion, retained tetraspanins (CD9, CD63 and CD81) expression. The anti-inflammatory activity of MSC-EVs was evaluated in vitro using OA chondrocytes, the expression of IL-6, IL-8 and COX-2 was significantly reduced after the treatment with hMSC-derived EVs isolated at early passage. The miRNA content of EVs was also investigated, we identify miRNA that are involved in specific biological function.

At the same time, we defined the best culture conditions to maintain iMSC and define the best time window in which to isolate EVs with highest biological activity.

In conclusion, a clinical grade serum-free medium was found to be suitable for the isolation and expansion of MSCs and iMSC with increased EVs production for therapeutic applications.

Acknowledgments: This project has received funding from the European Union's Horizon 2020 research and innovation programme under grant agreement No 874671


A.L. Graça R.M.A. Domingues D. Docheva M. Gomez-Florit M.E. Gomes

Worldwide, tendon disorders are one of the main causes of disability that decrease the quality of life of individuals and represent a substantial economic burden on society. Currently, the main therapies used for tendon injuries are not able to restore tendon functionality, and due to tendons' hypovascular and hypocellular nature, they present a reduced healing capacity, which also limits the success of the available therapies. In order to discover new therapies, extracellular vesicles (EVs), key players in cell-cell communication, have been widely explored for tissue engineering and regenerative medicine applications. Thus, the aim of this study is to assess the role of EVs derived from platelets in stem cell tenogenic commitment using a bioengineered tendon in vitro model for potential use as tendon therapeutic agents. Biomimetic platelet-derived EVs were produced by freeze-thaw cycles of platelets and isolation at different centrifugation speed. To recreate the architecture of tendons, a 3D system consisting of electrospun anisotropic nanofiber scaffolds coated with collagen encapsulating human adipose stem cells (hASCs) and different types of platelet-derived EVs, were produced. Then, the influence of the tendon-mimetic constructs and the distinct EVs populations in the hASCs tenogenic differentiation were assessed over culture time. We observed that the hASCs on the nanofibrous tendon scaffolds, show high cytoskeleton anisotropic organization that is characteristic of tenocytes. Moreover, acting as biological cues, platelet-derived EVs boosted hASCs tenogenic commitment, supported by the increased gene expression of tendon-related markers (SCX and TNMD). Additionally, EVs enhanced the deposition of tendon like extracellular matrix (ECM), as evidenced by the increased gene expression of ECM-related markers such as COL1, COL3, DCN, TNC, and MMP-3, which are fundamental for ECM synthesis and degradation balance. Moreover, EVs induced lower collagen matrix contraction on hASCs, which has been related with lower myofibroblast differentiation. Overall, the results revealed that EVs are capable of modulating stem cells' behavior boosting their tenogenic commitment, through the increased expression of healthy tendon cell markers, potentiating ECM deposition and decreasing cell contractility. Therefore, platelet EVs are a promising biochemical tool, worthy to be further explored, as paracrine signaling that might potentiate tendon repair and regeneration.


C. Gjerde

The aim of the ongoing projects was to demonstrate the efficacy of autologous bone marrow derived stem cells (MSC) combined with biomaterial to induced new bone formation in a randomized multicenter controlled clinical trial.

Patients with a need for bone reconstruction of residual edentulous ridges in both the mandible and maxilla due to bone defects with a vertical loss of alveolar bone volume and/or knife edge ridges (≤ than 4,5 mm) unable to provide adequate primary stabilization for dental implants were included in the clinical study. Autologous bone marrow MSC were expanded, loaded on BCP and used to augment the alveolar ridges. After five months bone biopsies were harvested at the implant position site and implants were installed in the regenerated bone. The implants were loaded after 8–12 weeks. Safety, efficacy, quality of life and success/survival were assessed. Five clinical centers, 4 different countries participated. Bone grafts harvested from the ramus of the mandibles were used as control in the projects.


N. Al-Sharabi

Growing evidence has suggested that paracrine mechanisms of Mesenchymal stem cell (MSC) may be involved in the underlying mechanism of MSC after transplantation, and extracellular vesicles (EVs) are an important component of this paracrine role. The aim of this study was to investigate the in vitro osteogenic effects of EVs derived from undifferentiated mesenchymal stem cells and from chemically induced to differentiate into osteogenic cells for 7 days. Further, the osteoinductive potential of EVs for bone regeneration in rat calvarial defects was assessed.

We could isolate and characterize EVs from naïve and osteogenic-induced MSCs. Proteomic analysis revealed that EVs contained distinct protein profiles, with Osteo-EVs having more differentially expressed proteins with osteogenic properties. EVs were found to enhance the proliferation and migration of cultured MSC. In addition, the study found that Osteo-EVs/MEM combination scaffolds could enhance greater bone formation after 4 weeks as compared to native MEM loaded with serum-free media.

The study suggests that EVs derived from chemically osteogenic-induced MSCs for 7 days can significantly enhance both the osteogenic differentiation activity of cultured hMSCs and the osteoinductivity of MEM scaffolds. The results indicate that Osteo-MSC-secreted nanocarriers-EVs combined with MEM scaffolds can be used for repairing bone defects.


S. Mohamed-Ahmed M.A. Yassin A. Rashad S.A. Lie S. Suliman H. Espedal S.B. Idris A. Finne-Wistrand K. Mustafa H. Vindenes I. Fristad

Mesenchymal stem cells (MSC) have been used for bone regenerative applications as an alternative approach to bone grafting. Selecting the appropriate source of MSC is vital for the success of this therapeutic approach. MSC can be obtained from various tissues, but the most used sources of MSC are Bone marrow (BMSC), followed by adipose tissue (ASC). A donor-matched comparison of these two sources of MSC ensures robust and reliable results.

Despite the similarities in morphology and immunophenotype of donor-matched ASC and BMSC, differences existed in their proliferation and in vitro differentiation potential, particularly osteogenic differentiation that was superior for BMSC, compared to ASC. However, these differences were substantially influenced by donor variations. In vivo, although the upregulated expression of osteogenesis-related genes in both ASC and BMSC, more bone was regenerated in the calvarial defects treated with BMSC compared to ASC, especially during the initial period of healing. According to these findings, compared to ASC, BMSC may result in faster regeneration and healing, when used for bone regenerative applications.


M. S. Aydin

Conventional 3D printing by itself is incapable of creating pores on a micro scale within deposited filaments throughout 3D scaffolds. These pores and hence larger surface areas are needed for cells to be adhered, proliferated, and differentiated. The aim of this work was to fabricate 3D polycaprolactone (PCL) scaffolds with internal multiscale porosity by using two different 3D printing techniques (ink/pellet of polymer-salt composite in low/high temperature printing) combined with salt leaching to improve cell adhesion, and cell proliferation besides to change degradation rate of PCL scaffolds:

1. Non-solvent phase separation integrated 3D printing of polymer-salt inks with various salt content (i.e., low temperature ink-based printing, LT).

2. FDM printing of composite polymer-salt pellets which will be obtained by casting and evaporating of prepared ink (i.e., high temperature composite-pellet-based printing, HT).

Further, the two approaches were followed by post salt leaching. Stem cells were able to attach on the surface and grow up to 14 days based on increasing cellular activities.


Å. Johansen J. Lin S. Yamada M. A. Yassin D. Hutchinson M. Malkoch K. Mustafa

Several synthetic polymers have been widely investigated for their use in bone tissue engineering applications, but the ideal material is yet to be engineered. Triazine-trione (TATO) based materials and their derivatives are novel in the field of biomedical engineering but have started to draw interest. Different designs of the TATO monomers and introduction of different chemical linkages and end-groups widens the scope of the materials due to a range of mechanical properties.

The aim of our work is to investigate novel TATO based materials, with or without hydroxyapatite filler, for their potential in bone tissue engineering constructs. Initially the biocompatibility of the materials was tested, indirectly and directly, according to ISO standards. Following this the osteoconductive properties were investigated with primary osteoblasts and an osteoblastic cell line. Bone marrow derived mesenchymal stem cells were used to evaluate the osteogenic differentiation and consequently the materials potential in bone tissue engineering applications.


H. Jahr

Degeneration of the intervertebral disc (IVD), and subsequent low back pain, is an almost inevitable cause of disability. The underlying mechanisms are complex and current therapeutic strategies mainly focus on symptomatic relief rather than on the intrinsic regeneration of the IVD. This talk will provide an overview of special anatomical features and the composition of the IVD as well as its cellular microenvironment. Selected promising conceptional regenerative approaches will be discussed.


M. V. Risbud

The hypoxic nucleus pulposus cells were thought to contain few, functionally redundant mitochondria. However in contrast to this widely held notion, new evidence shows presence of functional mitochondrial networks in disc cells. The lecture will discuss this evidence and provide insights into how microenvironmental cues govern mitochondrial function. The lecture will also discuss emerging evidence on how mitochondrial dysfunction of nucleus pulposus cells results in metabolic dysregulation and acquisition of a state that promotes inflammation and degeneration.


L. Ambrosio

In the last decades, the use of artificial intelligence (AI) has been increasingly investigated in intervertebral disc degeneration (IDD) and chronic low back pain (LBP) research. To date, several AI-based cutting-edge technologies, such as computer vision, computer-assisted diagnosis, decision support system and natural language processing have been utilized to optimize LBP prevention, diagnosis, and treatment. This talk will provide an outline on contemporary AI applications to IDD and LBP research, with a particular attention towards actual knowledge gaps and promising innovative tools.


G. Vadalá

The use of mesenchymal stem cell (MSCs) for intervertebral disc (IVD) regeneration has been extensively explored in the last two decades. MSCs are potent cell types that can be easily and safely harvested due to their abundancy and availability. Moreover, they are characterized by the capacity to differentiate towards IVD cells as well as release growth factors to support resident cell metabolism and recruit local progenitor cells to induce endogenous repair of degenerated IVDs. This talk will outline the characteristics of the main MSC sources and their effect towards IVD regeneration based on available preclinical and clinical evidence. In addition, innovative aspects of MSC-derived cell-free therapies will also be discussed.


C. Cicione V. Tilotta G. Di Giacomo L. Ambrosio F. Russo R. Papalia G. Vadalà V. Denaro

Low back pain (LBP) is a worldwide leading cause of disability. Treatment of intervertebral disc (IVD) with stem cells has been used on degenerate discs (IDD), cause of around 40% of LBP cases. Despite pain reduction, clinical studies' follow-up have not shown a structural IVD improvement. A valid alternative may be the use of notocordal cells (NC) or their precursors. Mesendoderm progenitor cells (MEPC) have the ability to replicate and differentiate toward NC. In this preliminary study we evaluated in a preclinical IDD model the viability and NC differentiation of MEPC derived from induced pluripotent stem cells (iPSC).

MEPC derived from iPSC were developed during the iPSpine project (# 825925), thawed, plated for 24h on laminin and labeled with PKH26.

Two adult sheep were subjected to nucleotomy of five lumbar discs for the induction of IDD. After 5 weeks, 3 degenerated discs were treated with MEPC at 3 different doses (low, medium and high). One sheep was sacrificed after 7 days and one after 30 days. Clinical parameters were collected to evaluate the safety of treatment. Discs were analysed using histological techniques. Survival (PKH26), proliferation (PCNA), notocordal cell differentiation (Brachyury, Cytokeratin 8/18/19, Sox9, Foxa2) and endodermal differentiation (Sox17) were evaluated.

At 7 days from treatment, both sheep lost about 20% of body weight. Only in discs treated with the highest dose PKH26 stained cells were alive up to 30 days. These cells turn out to be: proliferating (PCNA); positive for Brachyury, cytokeratin 8/18/19 and Foxa2; positive for SOX17 in a small percentage.

This preliminary study shows that MEPC, derived from iPSC and injected into ovine discs degenerated by nucleotomy, are able to survive up to 30 days and differentiate within the disc predominantly towards the notocordal phenotype.


Gun-Il Im

Extensive bone defects, caused by severe trauma or resection of large bone tumors, are difficult to treat. Regenerative medicine, including stem cell transplantation, may provide a novel solution for these intractable problems and improve the quality of life in affected patients. Adipose-derived stromal/stem cells (ASCs) have been extensively studied as cell sources for regenerative medicine due to their excellent proliferative capacity and the ability to obtain a large number of cells with minimal donor morbidity. However, the osteogenic potential of ASCs is lower than that of bone marrow-derived stromal/stem cells. To address this disadvantage, our group has employed various methods to enhance osteogenic differentiation of ASCs, including factors such as bone morphogenetic protein or Vitamin D, coculture with bone marrow stem cells, VEGF transfection, and gene transfer of Runx-2 and osterix. Recently, we mined a marker that can predict the osteogenic potential of ASC clones and also investigated the usefulness of the molecule as the enhancer of osteogenic differentiation of ASCs as well as its mechanism of action. Through RNA-seq gene analysis, we discovered that GSTT1 was the most distinguished gene marker between highly osteogenic and poorly osteogenic ASC clones. Knockdown of GSTT1 in high osteogenic ASCs by siGSTT1 treatment reduced mineralized matrix formation while GSTT1 overexpression by GSTT1 transfection or GSTT1 recombinant protein treatment enhanced osteogenic differentiation of low osteogenic ASCs. Metabolomic analysis confirmed significant changes of metabolites related to bone differentiation in ASCs transfected with GSTT1. A high total antioxidant capacity, low levels of cellular reactive oxygen species and increased GSH/GSSG ratios were also detected in GSTT1- transfected ASCs. GSTT1 can be a useful marker to screen the highly osteogenic ASC clones and also a therapeutic factor to enhance the osteogenic differentiation of poorly osteogenic ASC clones.


L. Sang-Soo

Wear debris from implant interfaces is the major factor leading to periprosthetic osteolysis. Fibroblast-like synoviocytes (FLSs) populate the intimal lining of the synovium and are in direct contact with wear debris. This study aimed to elucidate the effect of Ti particles as wear debris on human FLSs and the mechanism by which they might participate in the bone remodeling process during periprosthetic osteolysis. FLSs were isolated from synovial tissue from patients, and the condition medium (CM) was collected after treating FLSs with sterilized Ti particles. The effect of CM was analyzed for the induction of osteoclastogenesis or any effect on osteogenesis and signaling pathways. The results demonstrated that Ti particles could induce activation of the NFκB signaling pathway and induction of COX-2 and inflammatory cytokines in FLSs. The amount of RANL in the conditioned medium collected from Ti particle-stimulated FLSs (Ti CM) showed the ability to stimulate osteoclast formation. The Ti CM also suppressed the osteogenic initial and terminal differentiation markers for osteoprogenitors, such as alkaline phosphate activity, matrix mineralization, collagen synthesis, and expression levels of Osterix, Runx2, collagen 1α, and bone sialoprotein. Inhibition of the WNT and BMP signaling pathways was observed in osteoprogenitors after the treatment with the Ti CM. In the presence of the Ti CM, exogenous stimulation by WNT and BMP signaling pathways failed to stimulate osteogenic activity in osteoprogenitors. Induced expression of sclerostin (SOST: an antagonist of WNT and BMP signaling) in Ti particletreated FLSs and secretion of SOST in the Ti CM were detected. Neutralization of SOST in the Ti CM partially restored the suppressed WNT and BMP signaling activity as well as the osteogenic activity in osteoprogenitors. Our results reveal that wear debris-stimulated FLSs might affect bone loss by not only stimulating osteoclastogenesis but also suppressing the bone-forming ability of osteoprogenitors. In the clinical setting, targeting FLSs for the secretion of antagonists like SOST might be a novel therapeutic approach for preventing bone loss during inflammatory osteolysis.


H.B. Park

The rotator cuff tendinopathy is one of the most common shoulder problems leading to full-thickness rotator cuff tendon tear and, eventually, to degenerative arthritis. Recent research on rotator cuff tendon degeneration has focused on its relationship to cell death. The types of cell death known to be associated with rotator cuff tendon degeneration are apoptosis, necrosis, and autophagic cell death. The increased incidence of cell death in degenerative tendon tissue may affect the rates of collagen synthesis and repair, possibly weakening tendon tissue and increasing the risk of tendon rupture. The biomolecular mechanisms of the degenerative changes leading to apoptotic cell death in rotator cuff tenofibroblasts have been identified as oxidative-stress-related cascade mechanisms. Furthermore, apoptosis, necrosis, and autophagic cell death are all known to be mediated by oxidative stress, a condition in which ROS (reactive oxygen species) are overproduced. Lower levels of oxidative stress trigger apoptosis; higher levels mediate necrosis. Although the signaltransduction pathway leading to autophagy has not yet been fully established, ROS are known to be essential to autophagy. A neuronal theory regarding rotator cuff degeneration has been developed from the findings that glutamate, a neural transmitter, is present in increased concentrations in tendon tissues with tendinopathy and that it induces rat supraspinatus tendon cell death. Recent studies have reported that hypoxia involved in rotator cuff tendon degeneration. Because antioxidants are known to scavenge for intracellular ROS, some studies have been conducted to determine whether antioxidants can reduce cell death in rotator cuff tendon-origin fibroblasts. The first study reported that an antioxidant has the ability to reduce apoptosis in oxidative-stressed rotator cuff tenofibroblasts. The second study reported that antioxidants have both antiapoptotic effects and antinecrotic effects on rotator cuff tendon-origin fibroblasts exposed to an oxidative stimulus. The third study reported that an antioxidant has antiautophagic-cell-death effects on rotator cuff tendon-origin fibroblasts exposed to an oxidative stimulus. The fourth study reported that glutamate markedly increases cell death in rotator cuff tendonorigin fibroblasts. The glutamate-induced cytotoxic effects were reduced by an antioxidant, demonstrating its cytoprotective effects against glutamate-induced tenofibroblast cell death. The fifth study reported that hypoxia significantly increases intracellular ROS and apoptosis. The hypoxia-induced cytotoxic effects were markedly attenuated by antioxidants, demonstrating their cytoprotective effects against hypoxia-induced tenofibroblast cell death. In conclusion, antioxidants have cytoprotective effects on tenofibroblasts exposed in vitro to an oxidative stressor, a neurotransmitter, or hypoxia. These cytoprotective effects result from antiapoptotic, antinecrotic, and antiautophagic actions involving the inhibition of ROS formation. These findings suggest that antioxidants may have therapeutic potential for rotator cuff tendinopathy. Further studies must be conducted in order to apply these in vitro findings to clinical situations.


S.-G. Kim T.H. Kim J.H. Song J.H. Bae

To date, few studies have investigated the feasibility of the loop-mediated isothermal amplification (LAMP) assay for identifying pathogens in tissue samples. This study aimed to investigate the feasibility of LAMP for the rapid detection of methicillin-susceptible or methicillin-resistant Staphylococcus aureus (MSSA or MRSA) in tissue samples, using a bead-beating DNA extraction method. Twenty tissue samples infected with either MSSA (n = 10) or MRSA (n = 10) were obtained from patients who underwent orthopedic surgery for suspected musculoskeletal infection between December 2019 and September 2020. DNA was extracted from the infected tissue samples using the bead-beating method. A multiplex LAMP assay was conducted to identify MSSA and MRSA infections. To recognize the Staphylococcus genus, S. aureus, and methicillin resistance, 3 sets of 6 primers for the 16S ribosomal ribonucleic acid (rRNA) and the femA and mecA genes were used, respectively. The limit of detection and sensitivity (detection rate) of the LAMP assay for diagnosing MSSA and MRSA infection were analyzed. The results of this study suggest that the LAMP assay performed with tissue DNA samples can be a useful diagnostic method for the rapid detection of musculoskeletal infections caused by MSSA and MRSA.


K. H. Park

Fractures and related complications are a common challenge in the field of skeletal tissue engineering. Vitamin D and calcium are the only broadly available medications for fracture healing, while zinc has been recognized as a nutritional supplement for healthy bones. Here, we aimed to use polaprezinc, an anti-ulcer drug and a chelate form of zinc and L-carnosine, as a supplement for fracture healing. Polaprezinc induced upregulation of osteogenesis-related genes and enhanced the osteogenic potential of human bone marrow-derived mesenchymal stem cells and osteoclast differentiation potential of mouse bone marrow-derived monocytes. In mouse experimental models with bone fractures, oral administration of polaprezinc accelerated fracture healing and maintained a high number of both osteoblasts and osteoclasts in the fracture areas. Collectively, polaprezinc promotes the fracture healing process efficiently by enhancing the activity of both osteoblasts and osteoclasts. Therefore, we suggest that drug repositioning of polaprezinc would be helpful for patients with fractures.


N.W. Kucko J. Crowley D. Wills T. Wang M. Pelletier H. Yuan G. Houtzager C. Campion W.R. Walsh J. de Bruijn F. Barrère-de Groot

Biphasic calcium phosphate (BCP) with a characteristic needle-shaped submicron surface topography (MagnetOs) has attracted much attention due to its unique bone-forming ability which is essential for repairing critical-size bone defects such as those found in the posterolateral spine. Previous in vitro and ex-vivo data performed by van Dijk LA and Yuan H demonstrated that these specific surface characteristics drive a favorable response from the innate immune system.

This study aimed to evaluate and compare the in vivo performance of three commercially-available synthetic bone grafts, (1) i-FACTOR Putty®, (2) OssDsign® Catalyst Putty and (3) FIBERGRAFT® BG Matrix, with that of a novel synthetic bone graft in a clinically-relevant instrumented sheep posterolateral lumbar spine fusion (PLF) model. The novel synthetic bone graft comprised of BCP granules with a needle-shaped submicron surface topography (MagnetOs) embedded in a highly porous and fibrillar collagen matrix (MagnetOs Flex Matrix).

Four synthetic bone grafts were implanted as standalone in an instrumented sheep PLF model for 12 weeks (n=3 bilateral levels per group; levels L2/3 & L4/5), after which spinal fusion was determined by manual palpation, radiograph and µCT imaging (based on the Lenke scale), range-of-motion mechanical testing, and histological and histomorphological evaluation.

Radiographic fusion assessment determined bilateral robust bone bridging (Lenke scale A) in 3/3 levels for MagnetOs Flex Matrix compared to 1/3 for all other groups. For µCT, bilateral fusion (Lenke scale A) was found in 2/3 levels for MagnetOs Flex Matrix, compared to 0/3 for i-FACTOR Putty®, 1/3 for OssDsign® Catalyst Putty and 0/3 for FIBERGRAFT® BG Matrix. Fusion assessment for MagnetOs Flex Matrix was further substantiated by histology which revealed significant graft resorption complemented by abundant bone tissue and continuous bony bridging between vertebral transverse processes resulting in bilateral spinal fusion in 3/3 implants.

These results show that MagnetOs Flex Matrix achieved better fusion rates compared to three commercially-available synthetic bone grafts when used as a standalone in a clinically-relevant instrumented sheep PLF model.


F. Barbosa F. F. F. Garrudo P.S. Alberte M.S. Carvalho F. C. Ferreira J. C. Silva

The current procedures being applied in the clinical setting to address osteoporosis-related delayed union and nonunion bone fractures have been found to present mostly suboptimal outcomes. As a result, bone tissue engineering (BTE) solutions involving the development of implantable biomimetic scaffolds to replace damaged bone and support its regeneration are gaining interest. The piezoelectric properties of the bone tissue, which stem primarily from the significant presence of piezoelectric type I collagen fibrils in the tissue's extracellular matrix (ECM), play a key role in preserving the bone's homeostasis and provide integral assistance to the regeneration process. However, despite their significant potential, these properties of bone tend to be overlooked in most BTE-related studies. In order to bridge this gap in the literature, novel hydroxyapatite (HAp)-filled osteoinductive and piezoelectric poly(vinylidene fluoride-co-tetrafluoroethylene) (PVDF-TrFE) electrospun nanofibers were developed to replicate the bone's fibrous ECM composition and electrical features. Different HAp nanoparticle concentrations (1–10%, wt%) were tested to assess their effect on the physicochemical and biological properties of the resulting fibers. The fabricated scaffolds displayed biomimetic collagen fibril-like diameters, while also presenting mechanical features akin to type I collagen. The increase in HAp presence was found to enhance both surface and piezoelectric properties of the fibers, with an improvement in scaffold wettability and increase in β-phase nucleation (translating to increased piezoelectricity) being observed. The HAp-containing scaffolds also exhibited an augmented bioactivity, with a more comprehensive surface mineralization of the fibers being obtained for the scaffolds with the highest HAp concentrations. Improved osteogenic differentiation of seeded human mesenchymal stem/stromal cells was achieved with the addition of HAp, as confirmed by an increased ALP activity, calcium deposition and upregulated expression of key osteogenic markers. Overall, our findings highlight, for the first time, the potential of combining PVDF-TrFE and HAp to develop electroactive and osteoinductive nanofibers for BTE.

Acknowledgements: The authors thank FCT for funding through the projects InSilico4OCReg (PTDC/EME-SIS/0838/2021), OptiBioScaffold (PTDC/EME-SIS/4446/2020) and BioMaterARISES (EXPL/CTM-CTM/0995/2021), the PhD scholarship (2022.10572.BD) and to the research institutions iBB (UIDB/04565/2020 and UIDP/04565/2020) and Associate Laboratory i4HB (LA/P/0140/2020).


A. Ghaffari J. Rasmussen S. Kold O. Rahbek

Gait measurements can vary due to various intrinsic and extrinsic factors, and this variability becomes more pronounced using inertial sensors in a free-living environment. Therefore, identifying and quantifying the sources of variability is essential to ensure measurement reliability and maintain data quality.

This study aimed to determine the variability of daily accelerations recorded by an inertial sensor in a group of healthy individuals. Ten participants, four males and six females, with a mean age of 50 years (range: 29–61) and BMI of 26.9 kg/m2 (range: 21.4–36.8), were included. A single accelerometer continuously recorded lower limb accelerations over two weeks. We extracted and analyzed the accelerations of three consecutive strides within walking bouts if the time difference between the bouts was more than two hours. Multivariate mixed-effects modeling was performed on both the discretized acceleration waveforms at 101 points (0–100) and the harmonics of the signals in the frequency domain to determine the variance components for different subjects, days, bouts, and steps as the random effect variables. Intraclass correlation coefficients (ICCs) were calculated for between-day, between-bout, and between-step comparisons.

The results showed that the ICCs for the between-day, between-bout, and between-step comparisons were 0.73, 0.82, 0.99 for the vertical axis; 0.64, 0.75, 0.99 for the anteroposterior axis; and 0.55, 0.96, 0.97 for the mediolateral axis. For the signal harmonics, the respective ICCs were 0.98, 0.98, 0.99 for the vertical axis; 0.54, 0.93, 0.98 for the anteroposterior axis; and 0.69, 0.78, 0.95 for the mediolateral axis.

Overall, this study demonstrated that accelerations recorded continuously for multiple days in a free-living environment exhibit high variability, mainly between days, and some variability arising from differences between walking bouts during different times within days. However, reliable and repeatable gait measurements can be obtained by identifying and quantifying the sources of variability.


M. Maglio M. Tschon M. Sartori L. Martini M. Rocchi D. Dallari G. Giavaresi M. Fini

The use of implant biomaterials for prosthetic reconstructive surgery and osteosynthesis is consolidated in the orthopaedic field, improving the quality of life of patients and allowing for healthy and better ageing. However, there is the lack of advanced innovative methods to investigate the potentialities of smart biomaterials, particularly for the study of local effects of implant and osteointegration. Despite the complex process of osseointegration is difficult to recreate in vitro, the growing challenges in developing alternative models require to set-up and validate new approaches. Aim of the present study is to evaluate an advanced in vitro tissue culture model of osteointegration of titanium implants in human trabecular bone. Cubic samples (1.5×1.5 cm) of trabecular bone were harvested as waste material from hip arthroplasty surgery (CE AVEC 829/2019/Sper/IOR); cylindrical defects (2 mm Ø, 6 mm length) were created, and tissue specimens assigned to the following groups: 1) empty defects- CTR-; 2) defects implanted with a cytotoxic copper pin (Merck cod. 326429)- CTR+; 3) defects implanted with standard titanium pins of 6 µm-rough (ZARE S.r.l) -Ti6. Tissue specimens were cultured in mini rotating bioreactors in standard conditions, weekly assessing viability. At the 8-week-timepoint, immunoenzymatic, microtomographic, histological and histomorphometric analyses were performed. The model was able to simulate the effects of implantation of the materials, showing a drop in viability in CTR+, differently from Ti6 which appears to have a trophic effect on the bone. MicroCT and histological analysis supported the results, with lower BV/TV and Tb.Th values observed in CTR- compared to CTR+ and Ti6 and signs of matrix and bone deposition at the implant site. The collected data suggest the reliability of the tested model which can recreate the osseointegration process in vitro and can therefore be used for preliminary evaluations to reduce and refine in vivo preclinical models.

Acknowledgment: This work was supported by Emilia-Romagna Region for the project “Sviluppo di modelli biologici in vitro ed in silico per la valutazione e predizione dell'osteointegrazione di dispositivi medici da impianto nel tessuto osseo”


M. Akbar L.A.N. Crowe K. Woolcock J. Cole I.B. McInnes N.L. Millar

Dupuytren's disease (DD) is a fibroproliferative soft tissue disease affecting the palmar fascia of the hand causing permanent and irreversible flexion contracture. Aberrant fibrosis is likely to manifest through a combination of extrinsic, intrinsic, and environmental factors, including genetics and epigenetics. However, the role of epigenetics in soft tissue fibrosis in diseases such as DD is not well established. Therefore, we conducted a comprehensive multi-omic study investigating the epigenetic profiles that influence gene expression in DD pathology. Using control (patients undergoing carpal tunnel release) and diseased fibroblasts (patients undergoing Dupuytren's fasciectomy), we conducted ATAC-seq to assess differential chromatin accessibility between control and diseased fibroblasts. Additionally, ChIP-seq mapped common histone modifications (histone H4; H3K4me3, H3K9me3, H3K27me3, H4K16Ac, H4K20Me3) associated with fibrosis. Furthermore, we extracted RNA from control and DD tissue and performed bulk RNA-seq.

ATAC-seq analysis identified 2470 accessible genomic loci significantly more accessible in diseased fibroblasts compared to control. Comparison between diseased and control cells identified numerous significantly different peaks in histone modifications (H4K20me3, H3K27me3, H3K9me3) associated with gene repression in control cells but not in diseased cells. Pathway analysis demonstrated a substantial overlap in genes being de-repressed across these histone modifications (Figure 1). Both, ATAC-seq and ChIP-seq analysis indicated pathways such as cell adhesion, differentiation, and extracellular matrix organisation were dysregulated as a result of epigenetic changes. Moreover, de novo motif enrichment analysis identified transcription factors that possibly contributed to the differential gene expression between control and diseased tissue, including HIC1, NFATC1 and TEAD2. RNA-seq analysis found that these transcription factors were upregulated in DD tissue compared to control tissue.

The current epigenetic study provides insights into the aberrant fibrotic processes associated with soft tissue diseases such as DD and indicates that epigenetic-targeted therapies may be an interesting viable treatment option in future.

For any figures or tables, please contact the authors directly.


L. Belcastro V. Zubkovs M. Markocic S.H. Sajjadi C. Peez R. Tognato A. A. Boghossian S. Cattaneo S. Grad V. Basoli

Osteoarthritis (OA) is a degenerative joint disease affecting millions worldwide. Early detection of OA and monitoring its progression is essential for effective treatment and for preventing irreversible damage. Although sensors have emerged as a promising tool for monitoring analytes in patients, their application for monitoring the state of pathology is currently restricted to specific fields (such as diabetes). In this study, we present the development of an optical sensor system for real-time monitoring of inflammation based on the measurement of nitric oxide (NO), a molecule highly produced in tissues during inflammation.

Single-walled carbon nanotubes (SWCNT) were functionalized with a single-stranded DNA (ssDNA) wrapping designed using an artificial intelligence approach and tested using S-nitroso-N-acetyl penicillamine (SNAP) as a standard released-NO marker. An optical SWIR reader with LED excitation at 650 nm, 730 nm and detecting emission above 1000 nm was developed to read the fluorescence signal from the SWCNTs. Finally, the SWCNT was embedded in GelMa to prove the feasibility of monitoring the release of NO in bovine chondrocyte and osteochondral inflamed cultures (1–10 ng/ml IL1β) monitored over 48 hours. The stability of the inflammation model and NO release was indirectly validated using the Griess and DAF-FM methods. A microfabricated sensor tag was developed to explore the possibility of using ssDNA-SWCNT in an ex vivo anatomic set-up for surgical feasibility, the limit of detection, and the stability under dynamic flexion.

The SWCNT sensor was sensitive to NO in both in silico and in vitro conditions during the inflammatory response from chondrocyte and osteochondral plug cultures. The fluorescence signal decreased in the inflamed group compared to control, indicating increased NO concentration. The micro-tag was suitable and stable in joints showing a readable signal at a depth of up to 6 mm under the skin.

The ssDNA-SWCNT technology showed the possibility of monitoring inflammation continuously in an in vitro set-up and good stability inside the joint. However, further studies in vivo are needed to prove the possibility of monitoring disease progression and treatment efficacy in vivo.

Acknowledgments: The project was co-financed by Innosuisse (grant nr. 56034.1 IP-LS)


E.I. Bektas M. A. Wesdorp A. Schwab M.J. Stoddart A. Mata G.J.V.M. Van Osch M. D'Este

Biomaterials with mechanical or biological competence are ubiquitous in musculoskeletal disorders, and understanding the inflammatory response they trigger is key to guide tissue regeneration. While macrophage role has been widely investigated, immune response is regulated by other immune cells, including neutrophils, the most abundant leukocyte in human blood. As first responders to injury, infection or material implantation, neutrophils recruit other immune cells, and therefore influence the onset and resolution of chronic inflammation, and macrophage polarization. This response depends on the physical and chemical properties of the biomaterials, among other factors. In this study we report an in vitro culture model to describe the most important neutrophil functions in relation to tissue repair.

We identified neutrophil survival and death, neutrophils extracellular trap formation, release of reactive oxygen species and degranulation with cytokines release as key functions and introduced a corresponding array of assays. These tests were suitable to identify clear differences in the response by neutrophils that were cultured on material of different origin, stiffness and chemical composition. Overall, substrates from biopolymers of natural origin resulted in increased survival, less neutrophil extracellular trap formation, and more reactive oxygen species production than synthetic polymers. Within the range of mechanical properties explored (storage modulus below 5 k Pa), storage modulus of covalently crosslinked hyaluronic acid hydrogels did not significantly alter neutrophils response, whereas polyvinyl alcohol gels of matching mechanical properties displayed a response indicating increased activation.

Additionally, we present the effect of material stiffness, charge, coating and culture conditions in the measured neutrophils response. Further studies are needed to correlate the neutrophil response to tissue healing.

By deciphering how neutrophils initiate and modulate the immune response to material implantation, we aim at introducing new principles to design immunomodulatory biomaterials for musculoskeletal disorders.

Acknowledgments

This work was supported by the AO Foundation, AO CMF, grant AOCMF-21-04S.


H. Meng S. Verrier S. Grad Z. Li

Pericytes are contractile, motile cells that surround the capillary. Recent studies have shown that pericytes promoted joint fibrosis and induced subchondral bone angiogenesis, indicating the role of pericytes in osteoarthritis (OA). However, whether pericytes are involved in regulating inflammatory and catabolic response, as well as fibrotic repair of cartilage is still unclear. Here we used 2D and 3D models to investigate the communication of pericytes and chondrocytes under inflammatory osteoarthritis conditions.

CD34-CD146+ pericytes were isolated and sorted from human bone marrow. Human OA chondrocytes were isolated from OA joints. In 2D studies, monolayer cultured chondrocytes were treated +/- pericyte conditioned media, +/- 1ng/ml IL1β for 24h. In 3D studies, pericytes and chondrocytes were cultured within fibrin gel in 3D polyurethane scaffolds, separately or combined for 7 days, followed by treatment of +/- IL1β for another 7 days (Fig 2A). The inflammatory response, catabolic activity and expression of fibrosis markers of chondrocytes and pericytes were measured by ELISA and/or q-rtPCR.

Pericytes had weak inflammatory, catabolic and fibrotic response to IL1β (data not shown). The 2D study showed that pericyte conditioned media promoted inflammation, catabolism and fibrosis markers of chondrocytes, in the absence of IL1β treatment (Figure 1). However, study in 3D showed that coculture of chondrocytes and pericytes reduced the inflammatory and catabolic response of chondrocytes to IL1β and induced fibrosis markers in chondrocytes (Figure 2).

Pericytes are involved in regulating inflammatory response, catabolic response and fibrosis of chondrocytes. The opposite results from 2D and 3D experiments indicate the variety of the regulatory role of pericytes in the interaction with chondrocytes within different culture models. The underlying mechanism is under evaluation with on-going studies.

Acknowledgements

This study was funded by SINPAIN project, from European Union's Horizon Europe research and innovation programme under Grant Agreement NO. 101057778. Funded by the European Union. Views and opinions expressed are however those of the author(s) only and do not necessarily reflect those of the European Union. Neither the European Union nor the granting authority can be held responsible for them.

For any figures or tables, please contact the authors directly.


Marianna Tryfonidou

Tryfonidou leads the Horizon 2020 consortium (iPSpine; 2019–2023) bringing a transdisciplinary team of 21 partners together to address the challenges and bottlenecks of iPS-based advanced therapies towards their transition to the clinic. Here, chronic back pain due to intervertebral disc degeneration is employed as a show case. The project develops the iPS-technology and designed smart biomaterials to carry, protect and instruct the iPS cells within the degenerate disc environment. This work will be presented including ongoing activities focus on translating the developed methodology and tools towards clinically relevant animal models.

The consortium optimized the protocol for the differentiated iPS-notochordal-like cells (iPS-NLCs) and shortlisted two biomaterials shortlisted based on their physicochemical, cytotoxicity, biomechanical and biocompatibility testing. Both were shown to be safe and have been tested with the progenitors of iPS-NLCs. An advanced platform (e.g., the dynamic loading bioreactor for disc tissue) was used to evaluate their performance: the biomaterials supported the iPS-NLC progenitors after injection into the degenerate disc and seem to also support their maturation towards NLCs. Furthermore, we confirmed the capacity of these cells to survive inside degenerated discs at 30 days upon injection in sheep, whereafter we continued with their evaluation at 3 months post-injection. We achieved full evaluation of the sheep spines, including biomechanical analysis using the portable spine biomechanics tester prior analysis at the macro- and microscopic, and biochemical level.


L. Ambrosio G. Vadalà G. Petrucci F. Russo R. Papalia V. Denaro

Low back pain (LBP) is the main cause of disability worldwide and is primarily triggered by intervertebral disc degeneration (IDD). Although several treatment options exist, no therapeutic tool has demonstrated to halt the progressive course of IDD. Therefore, several clinical trials are being conducted to investigate different strategies to regenerate the intervertebral disc, with numerous studies not reaching completion nor being published. The aim of this study was to analyze the publication status of clinical trials on novel regenerative treatments for IDD by funding source and identify critical obstacles preventing their conclusion.

Prospective clinical trials investigating regenerative treatments for IDD and registered on ClinicalTrials.gov were included. Primary outcomes were publication status and investigational treatment funding. Fisher's exact test was utilized to test the association for categorical variables between groups.

25 clinical trials were identified. Among these, only 6 (24%) have been published. The most common source of funding was university (52%), followed by industry (36%) and private companies (12%). Investigational treatments included autologous (56%) or allogeneic (12%) products alone or in combination with a carrier or delivery system (32%). The latter were more likely utilized in industry or privately funded studies (Fig. 1, p=0.0112). No significant difference was found in terms of funding regarding the publication status of included trials (Table 1, p=0.9104).

Most clinical trials investigating regenerative approaches for the treatment of IDD were never completed nor published. This is likely due to multiple factors, including difficult enrollment, high dropout rate, and publication bias3. More accurate design and technical support from stakeholders and clinical research organization (CROs) may likely increase the quality of future clinical trials in the field.

For any figures or tables, please contact the authors directly.


V. Tilotta G. Di Giacomo C. Cicione L. Ambrosio F. Russo R. Papalia G. Vadalà V. Denaro

Invertebral disc degeneration (IDD) is a degenerative disease involving a variety of musculoskeletal and spinal disorders such as lower back pain (LBP). Secretome derived from mesenchymal stem cells (MSCs) have exerted beneficial effect on tissue regeneration. In this study, the goal was to investigate the paracrine and the anti-inflammatory effects of secretome from interleukin IL1β preconditioned Bone Marrow MSCs (BMSCs) on human nucleus pulposus cells (hNPCs) in a 3D in vitro model.

Secretome was collected from BMSCs (BMSCs-sec) after preconditioning with 10 ng/mL IL1β. hNPCs were isolated from surgical specimens, culture expanded in vitro, encapsulated in alginate beads and treated with: growth medium; IL1β 10 ng/mL; IL1β 10 ng/mL for 24 hours and then BMSCs-sec. We examined: i) cell proliferation and viability (flow cytometry), ii) nitrite production (Griess assay) and ROS quantification (Immunofluorescence) iii) glycosaminoglycan (GAG) amount (DMBB) and iv) gene expression levels of extracellular matrix (ECM) components and inflammatory mediators (qPCR). One-way ANOVA analysis was used to compare the groups under exam and data were expressed as mean ± S.D.

In vitro tests showed an enhancement of hNPCs proliferation after treatment with BMSCs-sec (p ≤ 0.05) compared to IL1β group. After 24 hours, the percentage of dead cells was higher in IL1β treated hNPCs compared to control group and decreased significantly in combined IL1β and BMSCs-sec sample group (p ≤ 0.01). Nitrite and ROS production were significantly mitigated and GAGs content was improved by preconditioned BMSCs-sec (p ≤ 0.05). Furthermore, gene expression levels were modulated by BMSCs-sec treatment compared to controls.

Our results supported the potential use of BMSCs' secretome as a cell-free strategy for IDD, overcoming the side effects of cell-therapy. Moreover, secretome derived from IL1β preconditioned BMSCs was able to reduce hNPCs death, attenuate ECM degradation and oxidative stress counteracting IDD progression.

Acknowledgements: Financial support was received from the “iPSpine” and “RESPINE” Horizon 2020 projects.


S. Tseranidou P. Bermudez-Lekerika M. Segarra-Queralt B. Gantenbein C.Le Maitre J. Piñero J. Noailly

Intervertebral disc (IVD) degeneration (IDD) involves imbalance between the anabolic and the catabolic processes that regulate the extracellular matrix of its tissues. These processes are complex, and improved integration of knowledge is needed. Accordingly, we present a nucleus pulposus cell (NPC) regulatory network model (RNM) that integrates critical biochemical interactions in IVD regulation and can replicate experimental results. The RNM was built from a curated corpus of 130 specialized journal articles. Proteins were represented as nodes that interact through activation and inhibition edges. Semi-quantitative steady states (SS) of node activations were calculated. Then, a full factorial sensitivity analysis (SA) identified which out of the RNM 15 cytokines, and 4 growth factors affected most the structural proteins and degrading enzymes. The RNM was further evaluated against metabolic events measured in non-healthy human NP explant cultures, after 2 days of 1ng/ml IL-1B catabolic induction. The RNM represented successfully an anabolic basal SS, as expected in normal IVD. IL-1B was able to increase catabolic markers and angiogenic factors and decrease matrix proteins. Such activity was confirmed by the explant culture measurements. The SA identified TGF-β and IL1RA as the two most powerful rescue mediators. Accordingly, TGFβ signaling-based IDD treatments have been proposed and IL-1RA gene therapy diminished the expression of proteases. It resulted challenging to simulate rescue strategies by IL-10, but interestingly, IL-1B could not induce IL-10 expression in the explant cultures. Our RNM was confronted to independent in vitro measurements and stands for a unique model, to integrate soluble protein signaling and explore IDD.

Acknowledgements: European Commission (Disc4All-ITN-ETN-955735)


S. Hofmann

Metabolic bone diseases, such as osteoporosis and osteopetrosis, result from an imbalanced bone remodeling process. In vitro bone models are often used to investigate either bone formation or resorption independently, while in vivo, these processes are coupled. Combining these processes in a co-culture is challenging as it requires finding the right medium components to stimulate each cell type involved without interfering with the other cell type's differentiation. Furthermore, differentiation stimulating factors often comprise growth factors in supraphysiological concentrations, which can overshadow the cell-mediated crosstalk and coupling.

To address these challenges, we aimed to recreate the physiological bone remodeling process, which follows a specific sequence of events starting with cell activation and bone resorption by osteoclasts, reversal, followed by bone formation by osteoblasts. We used a mineralized silk fibroin scaffold as a bone-mimetic template, inspired by bone's extracellular matrix composition and organization. Our model supported osteoclastic resorption and osteoblastic mineralization in the specific sequence that represents physiological bone remodeling.

We also demonstrated how culture variables, such as different cell ratios, base media, and the use of osteogenic/osteoclast supplements, and the application of mechanical load, can be adjusted to represent either a high bone turnover system or a self-regulating system. The latter system did not require the addition of osteoclastic and osteogenic differentiation factors for remodeling, therefore avoiding growth factor use.

Our in vitro model for bone remodeling has the potential to reduce animal experiments and advance in vitro drug development for bone remodeling pathologies like osteoporosis. By recreating the physiological bone remodeling cycle, we can investigate cell-cell and cell-matrix interactions, which are essential for understanding bone physiology and pathology. Furthermore, by tuning the culture variables, we can investigate bone remodeling under various conditions, potentially providing insights into the mechanisms underlying different bone disorders.


A. Pascuet-Fontanet M. Segarra-Queralt J. Noailly

Osteoarthritis (OA) leads to articular cartilage degradation, following complex dysregulation of chondrocyte's metabolism towards a catabolic state. Mechanical and biochemical signals are involved and need to be considered to understand the condition. Regulatory network-based models (RNM) successfully simulated the biological activity of the chondrocyte and the transduction of mechanical signals at the molecular and cell levels. However, the knowledge gap between single-cell regulation and intercellular communication in tissue volumes hinders the interpretability of such models at larger scales. Accordingly, a novel tissue-level biochemical model is proposed. We hypothesise that it is possible to simulate interacting network effects through the transport of diluted species in a finite-element model, to grasp relevant dynamics of cell and tissue regulation in OA. Chondrocyte RNM equations were translated into a reaction term of 18 multi-species diffusion model (e.g., 3 anti-inflammatory and 8 pro-inflammatory interleukins, 3 pro-anabolic and 1 pro-catabolic growth factors, 2 nociceptive factors and 2 pro-inflammatory cytokines). Elements with RNM reaction terms represented the chondrocytes and were distributed randomly through the model, according to known cellular density in the knee cartilage, and could both react to and produce diffusive entities through the pericellular matrix, associated with reduced diffusion coefficients. The model was constructed over a 2D square of 0.47 mm sides considered to be in the middle of the cartilage, so boundary conditions were settled as periodic. Different simulations were initialised with initial concentrations of either healthy or pro-OA mediators. Preliminary results showed that, independently of the initial conditions, the chondrocytes successfully evolved into anabolic states, in absence of sustained pro-catabolic external stimulations, in contrast to single-cell RNM [2]. Our intercellular model suggests that paracrine communication may increase robustness towards cartilage maintenance, and future tests shall reveal new OA dynamics.

Acknowledgements: Funding was provided by the European Commission (ERC-2021-CoG-O-Health-101044828).


P. Scala V. Giudice C. Selleri N. Maffulli L. Rehak G.D. Porta

Spontaneous muscle regenerative potential is limited, as severe injuries incompletely recover and result in chronic inflammation. Current therapies are restricted to conservative management, not providing a complete restitutio ad integrum; therefore, alternative therapeutic strategies are welcome, such as cell-based therapies with stem cells or Peripheral Blood Mononuclear Cells (PBMCs). Here, we described two different in vitro myogenic models: a 2D perfused system and a 3D bioengineered scaffold within a perfusion bioreactor. Both models were assembled with human bone marrow-derived mesenchymal stem cells (hBM-MSCs) and human primary skeletal myoblasts (hSkMs) to study induction and maintenance of myogenic phenotype in presence of PBMCs. When hBM-MSCs were cultured with human primary skeletal myoblasts (hSkMs) in medium supplemented with 10 ng/mL of bFGF; cells showed increased expression of myogenic-related gene, such as Desmin and Myosin Heavy Chain II (MYH2) after 21 days, and a prevalent expression of anti-inflammatory cytokines (IL10, 15-fold). Next, PBMCs were added in an upper transwell chamber and hBM-MSCs significantly upregulated myogenic genes throughout the culture period, while pro-inflammatory cytokines (e.g., IL12A) were downregulated. In 3D, hBM-MSCs plus hSkMs embedded in fibrin-based scaffolds, cultured in dynamic conditions, showed that all myogenic-related genes tended to be upregulated in the presence of PBMCs, and Desmin and MYH2 were also detected at protein level, while pro-inflammatory cytokine genes were significantly downregulated in the presence of PBMCs. In conclusion, our works suggest that hBM-MSCs have a versatile myogenic potential, enhanced and modulated by PMBCs. Moreover, our 3D biomimetic approach seemed to better resemble the tissue architecture allowing an efficient in vitro cellular cross-talk.


S. Schmidt F. Klampfleuthner S. Diederichs

The signaling molecule prostaglandin E2 (PGE2), synthesized by cyclooxygenase-2 (COX-2), is immunoregulatory and reported to be essential for skeletal stem cell function. Nonsteroidal anti-inflammatory drugs (NSAIDs) are widely used in osteoarthritis (OA) analgesia, but cohort studies suggested that long-term use may accelerate pathology. Interestingly, OA chondrocytes secrete high amounts of PGE2. Mesenchymal stromal cell (MSC) chondrogenesis is an in vitro OA model that phenocopies PGE2 secretion along with a hypertrophic OA-like cell morphology. Our aim was to investigate cause and effects of PGE2 secretion in MSC-based cartilage neogenesis and hypertrophy and identify molecular mechanisms responsible for adverse effects in OA analgesia.

Human bone marrow-derived MSCs were cultured in chondrogenic medium with TGFβ (10ng/mL) and treated with PGE2 (1µM), celecoxib (COX-2 inhibitor; 0.5µM), AH23848/AH6809 (PGE2 receptor antagonists; 10µM), or DMSO as a control (n=3–4). Assessment criteria were proteoglycan deposition (histology), chondrocyte/hypertrophy marker expression (qPCR), and ALP activity. PGE2 secretion was measured (ELISA) after TGFβ withdrawal (from day 21, n=2) or WNT inhibition (2µM IWP-2 from day 14; n=3).

Strong decrease in PGE2 secretion upon TGFβ deprivation or WNT inhibition identified both pathways as PGE2 drivers. Homogeneous proteoglycan deposition and COL2A1 expression analysis showed that MSC chondrogenesis was not compromised by any treatment. Importantly, hypertrophy markers (COL10A1, ALPL, SPP1, IBSP) were significantly reduced by PGE2 treatment, but increased by all inhibitors. Additionally, PGE2 significantly decreased ALP activity (2.9-fold), whereas the inhibitors caused a significant increase (1.3-fold, 1.7-fold, 1.8-fold). This identified PGE2 as an important inhibitor of chondrocyte hypertrophy.

Although TGFβ and WNT are known pro-arthritic signaling pathways, they appear to induce a PGE2-mediated antihypertrophic effect that can counteract pathological cell changes in chondrocytes. Hampering this rescue mechanism via COX inhibition using NSAIDs thus risks acceleration of OA progression, indicating the need of OA analgesia adjustment.


E. Strangmark J.H. Wang R. Al Hosni H. Muhammad M. Alkhrayef E. Robertson-Waters A. MacMillan B. Gompels A. Vogt W. Khan M. Birch A. McCaskie

Cell culture on tissue culture plastic (TCP) is widely used across biomedical research to understand the in vivo environment of a targeted biological system. However, growing evidence indicates that the characteristics of cells investigated in this way differ substantially from their characteristics in the human body. The limitations of TCP monolayer cell cultures are especially relevant for chondrocytes, the cell population responsible for producing cartilage matrix, because their zonal organization in hyaline cartilage is not preserved in a flattened monolayer assay. Here, we contrast the response of primary human chondrocytes to inflammatory cytokines, tumor necrosis factor-alpha and interferon-gamma, via transcriptional, translational, and histological profiling, when grown either on TCP or within a 3D cell pellet (scaffold-less). We focus on anti-apoptotic (Bcl2), pro-apoptotic (Bax, Mff, Fis1), and senescent (MMP13, MMP1, PCNA, p16, p21) markers. We find that the 3D environment of the chondrocyte has a profound effect on the behavior and fate of the cell; in TCP monolayer cultures, chondrocytes become anti-apoptotic and undergo senescence in response to inflammatory cytokines, whereas in 3D cell pellet cultures, they exhibit a pro-apoptotic response. Our findings demonstrate that chondrocyte culture environment plays a pivotal role in cell behavior, which has important implications for the clinical applicability of in vitro research of cartilage repair. Although there are practical advantages to 2D cell cultures, our data suggest researchers should be cautious when drawing conclusions if they intend to extrapolate findings to in vivo phenomena. Our data demonstrates opposing chondrocyte responses in relation to apoptosis and senescence, which appear to be solely reliant on the environment of the culture system. This biological observation highlights that proper experimental design is crucial to increase the clinical utility of cartilage repair experiments and streamline their translation to therapy development.


D. Kelly

Our musculoskeletal system has a limited capacity for repair. This has led to increased interest in the development of tissue engineering and biofabrication strategies for the regeneration of musculoskeletal tissues such as bone, ligament, tendon, meniscus and articular cartilage. This talk will demonstrate how different musculoskeletal tissues, specifically cartilage, bone and osteochondral defects, can be repaired using emerging biofabrication and 3D bioprinting strategies. This will include examples from our lab where cells and/or growth factors are bioprinted into constructs that can be implanted directly into the body, to approaches where biomimetic tissues are first engineered in vitro before in vivo implantation. The efficacy of these different biofabrication strategies in different preclinical studies will be reviewed, and lessons from the relative successes and failures of these approaches to tissue regeneration will be discussed.


S. Doyle D. Winrow T. Aregbesola J. Martin E. Pernevik V. Kuzmenko L. Howard K. Thompson M. Johnson C. Coleman

In 2021 the bone grafting market was worth €2.72 billion globally. As allograft bone has a limited supply and risk of disease transmission, the demand for synthetic grafting substitutes (BGS) continues to grow while allograft bone grafts steadily decrease. Synthetic BGS are low in mechanical strength and bioactivity, inspiring the development of novel grafting materials, a traditionally laborious and expensive process. Here a novel BGS derived from sustainably grown coral was evaluated. Coral-derived scaffolds are a natural calcium carbonate bio-ceramic, which induces osteogenesis in bone marrow mesenchymal stem cells (MSCs), the cells responsible for maintaining bone homeostasis and orchestrating fracture repair. By 3D printing MSCs in coral-laden bioinks we utilise high throughput (HT) fabrication and evaluation of osteogenesis, overcoming the limitations of traditional screening methods.

MSC and coral-laden GelXA (CELLINK) bioinks were 3D printed in square bottom 96 well plates using a CELLINK BIO X printer with pneumatic adapter Samples were non-destructively monitored during the culture period, evaluating both the sample and the culture media for metabolism (PrestoBlue), cytotoxicity (lactose dehydrogenase (LDH)) and osteogenic differentiation (alkaline phosphatase (ALP)). Endpoint, destructive assays used included qRT-PCR and SEM imaging.

The inclusion of coral in the printed bioink was biocompatable with the MSCs, as reflected by maintained metabolism and low LDH release. The inclusion of coral induced osteogenic differentiation in the MSCs as seen by ALP secretion and increased RUNX2, collagen I and osteocalcin transcription.

Sustainably grown coral was successfully incorporated into bioinks, reproducibly 3D printed, non-destructively monitored throughout culture and induced osteogenic differentiation in MSCs. This HT fabrication and monitoring workflow offers a faster, less labour-intensive system for the translation of bone substitute materials to clinic.

Acknowledgements: This work was co-funded by Enterprise Ireland and Zoan Biomed through Innovation Partnership IP20221024.


E. Ergene G. Liman G. Demirel P. Yilgor

Skeletal muscle tissue engineering has made progress towards production of functional tissues in line with the development in materials science and fabrication techniques. In particular, combining the specificity of 3D printing with smart materials has introduced a new concept called the 4D printing. Inspired by the unique properties of smart/responsive materials, we designed a bioink made of gelatin, a polymer with well-known cell compatibility, to be 3D printed on a magnetically responsive substrate. Gelatin was made photocrosslinkable by the methacrylate reaction (GELMA), and its viscosity was finetuned by blending with alginate which was later removed by alginate lyase treatment, so that the printability of the bioink as well as the cell viability can be finetuned. C2C12 mouse myoblasts-laden bioink was then 3D printed on a magnetic substrate for 4D shape-shifting. The magnetic substrate was produced using silicon rubber (EcoFlex) and carbonyl iron powders. After 3D printing, the bioink was crosslinked on the substrate, and the substrate was rolled with the help of a permanent magnet. Unrolled (Open) samples were used as the control group. The stiffness of the bioink matrix was found to be in the range of 13–45 kPa, which is the appropriate value for the adhesion of C2C12 cells. In the cell viability analysis, it was observed that the cells survived and could proliferate within the 7-day duration of the experiment. As a result of the immunofluorescence test, compared to the Open Group, more cell nuclei were observed overlapping MyoD1 expression in the Rolled Group; this indicated that the cells in these samples had more cell-cell interactions and therefore tended to form more myotubes.

Acknowledgements: This research was supported by the TÜBİTAK 2211-A and YÖK 100/2000 scholarship programs.


G. McDermott M. Domingos B. Barkatali S. Richardson

Meniscal injuries affect over 1.5 million people across Europe and the USA annually. Injury greatly reduces knee joint mobility and quality of life and frequently leads to the development of osteoarthritis. Tissue engineered strategies have emerged in response to a lack of viable treatments for meniscal pathologies. However, to date, constructs mimicking the structural and functional organisation of native tissue, whilst promoting deposition of new extracellular matrix, remains a bottleneck in meniscal repair. 3D bioprinting allows for deposition and patterning of biological materials with high spatial resolution. This project aims to develop a biomimetic 3D bioprinted meniscal substitute.

Meniscal tissue was characterised to effectively inform the design of biomaterials for bioprinting constructs with appropriate structural and functional properties. Histology, gene expression and mass spectrometry were performed on native tissue to investigate tissue architecture, matrix components, cell populations and protein expression regionally across the meniscus. 3D laser scanning and magnetic resonance imaging were employed to acquire the external geometrical information prior to fabrication of a 3D printed meniscus. Bioink suitability was investigated through regional meniscal cell encapsulation in blended hydrogels, with the incorporation of growth factors and assessed for their suitability through rheology, scanning electron microscopy, histology and gene expression analysis.

Meniscal tissue characterisation revealed regional variations in matrix compositions, cellular populations and protein expression. The process of imaging through to 3D printing highlighted the capability of producing a construct that accurately replicated meniscal geometries. Regional meniscal cell encapsulation into hydrogels revealed a recovery in cell phenotype, with the incorporation of growth factors into the bioink's stimulating cellular re-differentiation and improved zonal functionality.

Meniscus biofabrication highlights the potential to print patient specific, customisable meniscal implants. Achieving zonally distinct variations in cell and matrix deposition highlights the ability to fabricate a highly complex tissue engineered construct.

Acknowledgements: This work was undertaken as part of the UK Research and Innovation (UKRI)-funded CDT in Advanced Biomedical Materials.


D.B. Dias R. Fritsche-Guenther W. Chan A. Ellinghaus G.N. Duda J. Kirwan P.S.P. Poh

The ability of the body to constantly maintain metabolism homeostasis while fulling the heightened energy and macromolecule demand is crucial to ensure successful tissue healing outcomes. Studies investigating the local metabolic environment during healing are scarce to date. Here, using Type 2 Diabetes (T2D) as a study model, we investigate the impact of metabolism dysregulation on scaffold-guided large-volume bone regeneration. Our study treated wild-type or T2D rats with 5 mm critical-sized femoral defects with 3D-printed polycaprolactone (PCL) scaffolds with 70% porosity. Metabolomics was leveraged for a holistic view of metabolism alteration as healing progress and correlated to regenerated bone tissue volume and quality assessed using micro-computed tomography (µ-CT), histology, and immunohistology. Semi-targeted metabolomics analysis indicated dysregulation in the glycolysis and TCA cycle – the main energy production pathways, in T2D compared to healthy animals. The abundance of metabolites substrates, i.e., amino acids – for protein/ extracellular matrix synthesis was also affected in T2D. Tissue-level metabolites observations aligned with morphological observation with less newly formed bone observed in T2D than wild-type rats. This study enlightens the metabolism landscape during scaffold-guided large-volume bone regeneration in wild-type vs. T2D to further guide the personalization of the scaffold to drive successful regeneration.


M.S. Carvalho J.M.S. Cabral C.L. da Silva

Mesenchymal stromal cells (MSC) have been proposed as an emerging cell therapy for bone tissue engineering applications. However, the healing capacity of the bone tissue is often compromised by patient's age and comorbidities, such as osteoporosis. In this context, it is important to understand the impact of donor age on the therapeutic potential of MSC. Importantly, the impact on donor age is not restricted to cells themselves but also to their microenvironment that is known to affect cell function.

The extracellular matrix (ECM) has an important role in stem cell microenvironment, being able to modulate cell proliferation, self-renewal and differentiation. Decellularized cell-derived ECM (dECM) has been explored for regenerative medicine applications due to its bioactivity and its resemblance to the in vivo microenvironment. Thus, dECM offers the opportunity not only to develop microenvironments with customizable properties for improvement of cellular functions but also as a platform to study cellular niches in health and disease. In this study, we investigated the capacity of the microenvironment to rescue the impaired proliferative and osteogenic potential of aged MSC. The goal of this work was to understand if the osteogenic capacity of MSC could be modulated by exposure to a dECM derived from cells obtained from young donors. When aged MSC were cultured on dECM derived from young MSC, their in vitro proliferative and osteogenic capacities were enhanced. Our results suggest that the microenvironment, specifically the ECM, plays a crucial role in the osteogenic differentiation capacity of MSC. dECM might be a valuable clinical strategy to overcome the age-related decline in the osteogenic potential of MSC by recapitulating a younger microenvironment, attenuating the effects of aging on the stem cell niche. Overall, this study opens new possibilities for developing clinical strategies for elderly patients with limited bone formation capacity who currently lack effective treatments.

Acknowledgements: The authors thank FCT for funding through the project DentalBioMatrix (PTDC/BTM-MAT/3538/2020) and to the research institutions iBB (UIDB/04565/2020 and UIDP/04565/2020) and Associate Laboratory i4HB (LA/P/0140/2020).


S. Häusner K. Horas T. Blunk M. Herrmann

Autografts containing bone marrow (BM) are current gold standard in the treatment of critical size bone defects, delayed union and bone nonunion defects. Although reaching unprecedented healing rates in bone reconstruction, the mode of action and cell-cell interactions of bone marrow mononuclear cell (BM-MNC) populations have not yet been described. BM-MNCs consist of a heterogeneous mixture of hematopoetic and non-hematopoetic lineage fractions. Cell culture in a 3D environment is necessary to reflect on the complex mix of these adherend and non-adherend cells in a physiologically relevant context. Therefore, the main aim of this approach was to establish conditions for a stable 3D BM-MNC culture to assess cellular responses on fracture healing strategies.

BM samples were obtained from residual material after surgery with positive ethical vote and informed consent of the patients. BM-MNCs were isolated by density gradient centrifugation, and cellular composition was determined by flow cytometry to obtain unbiased data sets on contained cell populations. Collagen from rat tail and human fibrin was used to facilitate a 3D culture environment for the BM-MNCs over a period of three days. Effects on cellular composition that could improve the regenerative potential of BM-MNCs within the BM autograft were assessed using flow cytometry. Cell-cell-interactions were visualized using confocal microscopy over a period of 24 hours. Cell localization and interaction partners were characterized using immunofluorescence labeled paraffin sectioning.

Main BM-MNC populations like Monocytes, Macrophages, T cells and endothelial progenitor cells were determined and could be conserved in 3D culture over a period of three days. The 3D cultures will be further treated with already clinically available reagents that lead to effects even within a short-term exposure to stimulate angiogenic, osteogenic or immunomodulatory properties. These measures will help to ease the translation from “bench to bedside” into an intraoperative protocol in the end.


M.R. Iaquinta C. Lanzillotti M. Tognon F. Martini M.J. Stoddart E. D. Bella

The effects of dexamethasone (dex), during in vitro human osteogenesis, are contrasting. Indeed, dex downregulates SOX9 during osteogenic differentiation of human bone marrow mesenchymal stromal cells (HBMSCs). However, dex also promotes PPARG expression, resulting in the formation of adipocyte-like cells within the osteogenic monolayers. The regulation of both SOX9 and PPARG seems to be downstream the transactivation activity of the glucocorticoid receptor (GR), thus the effect of dex on SOX9 downregulation is indirect. This study aims at determining whether PPAR-γ regulates SOX9 expression levels, as suggested by several studies.

HBMSCs were isolated from bone marrow of patients with written informed consent. HBMSCs were cultured in different osteogenic induction media containing 10 or 100 nM dex. Undifferentiated cells were used as controls. Cells were treated either with a pharmacological PPAR-γ inhibitor T0070907 (donors n=4) or with a PPARG-targeting siRNA (donors n=2). Differentiation markers or PPAR-γ target genes were analysed by RT-qPCR. Mineral deposition was assessed by ARS staining. Two-way ANOVA followed by a Tukey's multiple comparison test compared the effects of treatments.

At day 7, T0070907 downregulated ADIPOQ and upregulated CXCL8, respectively targets of PPAR-γ-mediated transactivation and transrepression. RUNX2 and SOX9 were also significantly downregulated in absence of dex. PPARG was successfully downregulated by siRNA. ADIPOQ expression was also inhibited, while CXCL8 did not show any significant difference between siRNA treatment groups. RUNX2 was downregulated by the PPARG-siRNA treatment in presence of 100 nM dexamethasone, while SOX9 levels were not affected. ARS showed no change in the mineralization levels when PPARG expression or activity was inhibited.

Understanding how dex regulates HBMSC differentiation is of pivotal importance to refine current in vitro models. These results suggest that PPARG does not mediate SOX9 downregulation. Unexpectedly, RUNX2 expression was also unaltered or even downregulated after PPAR-γ inhibition.

Acknowledgements: AO Foundation, AO Research Institute (CH) and PRIN 2017 MUR (IT) for financial support.


M. Seah M. Birch I. Moutsopoulos I. Mohorianu A. McCaskie

Despite osteoarthritis (OA) representing a large burden for healthcare systems, there remains no effective intervention capable of regenerating the damaged cartilage in OA. Mesenchymal stromal cells (MSCs) are adult-derived, multipotent cells which are a candidate for musculoskeletal cell therapy. However, their precise mechanism of action remains poorly understood.

The effects of an intra-articular injection of human bone-marrow derived MSCs into a knee osteochondral injury model were investigated in C57Bl/6 mice. The cell therapy was retrieved at different time points and single cell RNA sequencing was performed to elucidate the transcriptomic changes relevant to driving tissue repair. Mass cytometry was also used to study changes in the mouse immune cell populations during repair.

Histological assessment reveals that MSC treatment is associated with improved tissue repair in C57Bl/6 mice. Single cell analysis of retrieved human MSCs showed spatial and temporal transcriptional heterogeneity between the repair tissue (in the epiphysis) and synovial tissue. A transcriptomic map has emerged of some of the distinct genes and pathways enriched in human MSCs isolated from different tissues following osteochondral injury. Several MSC subpopulations have been identified, including proliferative and reparative subpopulations at both 7 days and 28 days after injury. Supported by the mass cytometry results, the immunomodulatory role of MSCs was further emphasised, as MSC therapy was associated with the induction of increased numbers of regulatory T cells correlating with enhanced repair in the mouse knee.

The transcriptomes of a retrieved MSC therapy were studied for the first time. An important barrier to the translation of MSC therapies is a lack of understanding of their heterogeneity, and the consequent lack of precision in its use. MSC subpopulations with different functional roles may be implicated in the different phases of tissue repair and this work offers further insights into repair process.


A. Ghaffari R.E. Kildahl Lauritsen M. Christensen T.R. Thomsen H. Mahapatra R. Heck S. Kold O. Rahbek

Smartphones are often equipped with inertial sensors capable of measuring individuals' physical activities. Their role in monitoring the patients' physical activities in telemedicine, however, needs to be explored. The main objective of this study was to explore the correlation between a participant's daily step counts and the daily step counts reported by their smartphone. This prospective observational study was conducted on patients undergoing lower limb orthopedic surgery and a group of non-patients. The data collection period was from 2 weeks before until four weeks after the surgery for the patients and two weeks for the non-patients. The participants' daily steps were recorded by physical activity trackers employed 24/7, and an application recorded the number of daily steps registered by the participants' smartphones. We compared the cross-correlation between the daily steps time-series taken from the smartphones and physical activity trackers in different groups of participants. We also employed mixed modeling to estimate the total number of steps. Overall, 1067 days of data were collected from 21 patients (11 females) and 10 non-patients (6 females). The cross-correlation coefficient between the smartphone and physical activity tracker was 0.70 [0.53–0.83]. The correlation in the non-patients was slightly higher than in the patients (0.74 [0.60–0.90] and 0.69 [0.52–0.81], respectively). Considering the ubiquity, convenience, and practicality of smartphones, the high correlation between the smartphones and the total daily step time-series highlights the potential usefulness of smartphones in detecting the change in the step counts in remote monitoring of the patient's physical activity.


E. Muñoz-Moya C. Ruiz G. Piella J. Noailly

This study investigates the relationships between Intervertebral Disc (IVD) morphology and biomechanics using patient-specific (PS) finite element (FE) models and poromechanical simulations.

169 3D lumbar IVD shapes from the European project MySpine (FP7-269909), spanning healthy to Pfirrmann grade 4 degeneration, were obtained from MRIs. A Bayesian Coherent Point Drift algorithm aligned meshes to a previously validated structural FE mesh of the IVD. After mesh quality analyses and Hausdorff distance measurements, mechanical simulations were performed: 8 and 16 hours of sleep and daytime, respectively, applying 0.11 and 0.54 MPa of pressure on the upper cartilage endplate (CEP). Simulation results were extracted from the anterior (ATZ) and posterior regions (PTZ) and the center of the nucleus pulposus (CNP). Data mining was performed using Linear Regression, Support Vector Machine, and eXtreme Gradient Boosting techniques. Mechanical variables of interest in DD, such as pore fluid velocity (FLVEL), water content, and swelling pressure, were examined. The morphological variables of the simulated discs were used as input features.

Local morphological variables significantly impacted the local mechanical response. The local disc heights, respectively in the mid (mh), anterior (ah), and posterior (ph) regions, were key factors in general. Additionally, fluid transport, reflected by FLVEL, was greatly influenced (r2 0.69) by the shape of the upper and lower cartilage endplates (CEPs).

This study suggests that disc morphology affects Mechanical variables of interest in DD. Attention should be paid to the antero-posterior distribution and local effects of disc heights. Surprisingly, the CEP morphology remotely affected the fluid transport in NP volumes around mid-height, and mechanobiological implications shall be explored. In conclusion, patient-specific IVD modeling has strong potential to unravel important correlations between IVD phenotypes and local tissue regulation.

Acknowledgments: European Commission: Disc4All-MSCA-2020-ITN-ETN GA: 955735; O-Health-ERC-CoG-2021-101044828


G. Rösch A. E. Rapp P. Tsai H. Kohler S. Taheri A. F. Schilling F. Zaucke D. Slattery Z. Jenei-Lanzl

Osteoarthritis (OA) affects the whole joint and leads to chronic pain. The sympathetic nervous system (SNS) seems to be involved in OA pathogenesis, as indicated by in vitro studies as well as by our latest work demonstrating that sympathectomy in mice results in increased subchondral bone volume in the OA knee joint. We assume that chronic stress may lead to opposite effects, such as an increased bone loss in OA due to an elevated sympathetic tone. Therefore, we analyzed experimental OA progression in mice exposed to chronic stress. OA was induced in male C57BL/6J mice by surgical destabilization of the medial meniscus (DMM) and Sham as well as non-operated mice served as controls. Half of these groups were exposed to chronic unpredictable mild stress (CUMS). After 12 weeks, chronic stress efficiency was assessed using behavioral tests. In addition to measuring body weight and length, changes in subchondral bone were analyzed by μCT. Dynamic Weight Bearing system was used to monitor OA-related pain. Histological scoring will be conducted to investigate the severity cartilage degeneration and synovial inflammation. CUMS resulted in increased anxiety and significant decrease in body weight gain in all CUMS groups compared to non-CUMS groups. CUMS also increased serum corticosterone in healthy mice, with even higher levels in CUMS mice after DMM surgery. CUMS had no significant effect on subchondral bone, but subarticular bone mineral density and trabecular thickness were increased. Moreover, CUMS resulted in significant potentiation of DMM-associated pain. Our results suggest that the autonomic imbalance with increased sympathetic nervous activity induced by chronic stress exacerbates the severity of OA pain perception. We expect significantly increased cartilage degeneration as well as more severe synovial inflammation in CUMS DMM mice compared to DMM mice.


W. van der Weegen T. Warren R. Agricola D. Das M. Siebelt

Artificial Intelligence (AI) is becoming more powerful but is barely used to counter the growth in health care burden. AI applications to increase efficiency in orthopedics are rare. We questioned if (1) we could train machine learning (ML) algorithms, based on answers from digitalized history taking questionnaires, to predict treatment of hip osteoartritis (either conservative or surgical); (2) such an algorithm could streamline clinical consultation.

Multiple ML models were trained on 600 annotated (80% training, 20% test) digital history taking questionnaires, acquired before consultation. Best performing models, based on balanced accuracy and optimized automated hyperparameter tuning, were build into our daily clinical orthopedic practice. Fifty patients with hip complaints (>45 years) were prospectively predicted and planned (partly blinded, partly unblinded) for consultation with the physician assistant (conservative) or orthopedic surgeon (operative). Tailored patient information based on the prediction was automatically sent to a smartphone app. Level of evidence: IV.

Random Forest and BernoulliNB were the most accurate ML models (0.75 balanced accuracy). Treatment prediction was correct in 45 out of 50 consultations (90%), p<0.0001 (sign and binomial test). Specialized consultations where conservatively predicted patients were seen by the physician assistant and surgical patients by the orthopedic surgeon were highly appreciated and effective.

Treatment strategy of hip osteoartritis based on answers from digital history taking questionnaires was accurately predicted before patients entered the hospital. This can make outpatient consultation scheduling more efficient and tailor pre-consultation patient education.


R. Wendlandt T. Volpert J. Schroeter A.P. Schulz A. Paech

Gait analysis is an indispensable tool for scientific assessment and treatment of individuals whose ability to walk is impaired. The high cost of installation and operation are a major limitation for wide-spread use in clinical routine.

Advances in Artificial Intelligence (AI) could significantly reduce the required instrumentation. A mobile phone could be all equipment necessary for 3D gait analysis. MediaPipe Pose provided by Google Research is such a Machine Learning approach for human body tracking from monocular RGB video frames that is detecting 3D-landmarks of the human body.

Aim of this study was to analyze the accuracy of gait phase detection based on the joint landmarks identified by the AI system.

Motion data from 10 healthy volunteers walking on a treadmill with a fixed speed of 4.5km/h (Callis, Sprintex, Germany) was sampled with a mobile phone (iPhone SE 2nd Generation, Apple). The video was processed with Mediapipe Pose (Version 0.9.1.0) using custom python software. Gait phases (Initial Contact - IC and Toe Off - TO) were detected from the angular velocities of the lower legs. For the determination of ground truth, the movement was simultaneously recorded with the AS-200 System (LaiTronic GmbH, Innsbruck, Austria).

The number of detected strides, the error in IC detection and stance phase duration was calculated.

In total, 1692 strides were detected from the reference system during the trials from which the AI-system identified 679 strides. The absolute mean error (AME) in IC detection was 39.3 ± 36.6 ms while the AME for stance duration was 187.6 ± 140 ms.

Landmark detection is a challenging task for the AI-system as can clearly be seen be the rate of only 40% detected strides. As mentioned by Fadillioglu et al., error in TO-detection is higher than in IC-detection.


S.Y. W. Wong S. Grant

Robotic assistance in knee arthroplasty has become increasingly popular due to improved accuracy of prosthetic implantation. However, literature on the mid-term outcomes is limited especially that of hand-held robotic-assisted devices. We present one of the longest follow-up series to date using this novel technology and discuss the learning curve for introducing robotic technology into our practice.

The purpose of this single-surgeon study is to evaluate the survival, patient-reported outcomes and learning curve for handheld boundary-controlled robotic-assisted unicompartmental knee arthroplasties (HBRUKAs) at our hospital.

This retrospective study evaluates 100 cases (94 Medial, 6 Lateral) performed by a single surgeon between October 2012 and July 2018. 52% were males, mean age was 64.5y (range 47.3y-85.2y) and mean BMI was 31.3 (range 21.8–43). Both inlay (40%) and onlay (60%) designs were implanted. Patients were followed up routinely at 1 and 5 years with Oxford Knee Scores (OKS) recorded. The learning curve was determined by tourniquet times.

At a mean follow-up of 4.3 years (range 1.6y–7.3y), survivorship was 97%. There were three revisions: One case of aseptic loosening (1.5y), one case of deep-infection (3.8y) and one case of contralateral compartment osteoarthritis progression (5y). Mean 5-year OKS was 39.8. A 14.3% reduction in mean tourniquet times between the first 25 cases (105.5minutes) and subsequent cases (90.4minutes) was seen.

This single-surgeon study showed good survivorship and patient-reported outcomes for HBRUKAs at our hospital. A learning curve of approximately 25 cases was shown, with significant decreases in tourniquet times with respect to increased surgeon experience.


M. Alkhrayef H. Muhammad R. Al Hosni A. McCaskie M. Birch

Tissue repair is believed to rely on tissue-resident progenitor cell populations proliferating, migrating, and undergoing differentiation at the site of injury. During these processes, the crosstalk between mesenchymal stromal/stem cells (MSCs) and macrophages has been shown to play a pivotal role. However, the influence of extracellular matrix (ECM) remodelling in this crosstalk, remains elusive.

Human MSCs cultured on tissue culture plastic (TCP) and encased within fibrin in vitro were treated with/without TNFα and IFNγ. Human monocytes were cocultured with untreated/pretreated MSCs on TCP or within fibrin. After seven days, the conditioned media (CM) were collected. Human chondrocytes were exposed to CM in a migration assay. The impact of TGFβ was assessed by adding an inhibitor (TGFβRi). Cell activity was assessed using RT-qPCR and XL-protein-profiler-array.

Previously, we demonstrated that culturing human MSCs within 3D-environments significantly enhances their immunoregulatory activity in response to pro-inflammatory stimuli. In this study, monocytes were co-cultured with MSCs within fibrin, acquiring a distinct M2-like repair macrophage phenotype in contrast to TCP co-cultures. MSC/macrophage CM characterization using a protein array demonstrated differences in release of several factors, including chemokines, growth factors and ECM components. Chondrocyte migration was significantly reduced in CM from untreated MSC/monocytes co-cultures in fibrin compared to CM of untreated MSCs/monocytes on TCP. This impact on migration was not seen with chondrocytes cultured in CM of monocytes co-cultured with pretreated MSCs in fibrin. The CM of monocytes co-cultured with pretreated MSCs in fibrin up-regulates COL2A1 and SOX9 compared to TCP. Chondrogenesis and migration were TGFβ dependent.

MSC/macrophage crosstalk and responsiveness to cytokines are influenced by the ECM environment, which subsequently impacts tissue-resident cell migration and chondrogenesis. The direct effects of ECM on MSC/macrophage secretory phenotype is complemented by the dynamic ECM binding and release of growth factors such as TGFβ.


G. Anghileri W. DeVoogt CS. Seinen B. Peacock P. Vader I. Martin-Fabiani O.G. Davies

Matrix-bound vesicles (MBVs) are embedded within osteoid and function as the site of initial mineral formation. However, they remain insufficiently characterised in terms of biogenesis, composition and function while their relationship with secreted culture medium EVs (sEVs) such as exosomes remains debated. We aimed to define the biogenesis and pro-mineralisation capacity of MBVs and sEVs to understand their potential in regenerative orthopaedics.

sEVs and MBVs isolated from conditioned medium (differential ultracentrifugation) and ECM (collagenase digestion and differential ultracentrifugation) of mineralising MC3T3 pre-osteoblast and human bone marrow MSC cultures were characterised by nanoparticle tracking analysis, western blotting, nano-flow cytometry, super resolution microscopy (ONI) and TEM. Immunoprecipitated populations positive for alkaline phosphatase (ALP), a putative marker of mineralisation capacity, were also characterised. Collagen binding efficiency was evaluated using MemGlow staining.

Results reported were comparative across both cell lines. Western blots indicated MBV fractions were positive for markers of endosomal biogenesis (CD9, CD81, ALIX, TSG101) and pro-mineralising proteins (ALP, Pit1, Annexin II, Annexin V), with Annexin V and CD9 present in immunoprecipitated ALP-positive fractions. MBVs were significantly larger than sEVs (p<0.05) and contained a higher amount of ALP (p<0.05) with a significant increase from day 7 to day 14 of cellular mineralisation (p<0.05). This mirrored the pattern of electron-dense vesicles seen via TEM. Super resolution single vesicle analysis revealed for the first-time co-expression of ALP with markers of endosomal biogenesis (CD9, CD63, CD81, ALIX) and Annexin II in both vesicle types, with higher co-expression percentage in MBVs than sEVs. MBVs also exhibited preferential collagen binding.

Advanced imaging methods demonstrated that contrary to opinions in the field, MBVs appear to possess exosomal markers and may arise via endosomal biogenesis. However, it was evident that a higher proportion of MBVs possessed machinery to induce mineralisation and were enriched in mineral-dense material.