Advertisement for orthosearch.org.uk
The Bone & Joint Journal Logo

Receive monthly Table of Contents alerts from The Bone & Joint Journal

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Volume 74-B, Issue 1 January 1992

J Goodfellow
View article
Download PDF

Access Required
AM Jackson
View article
Download PDF

G Horne
View article
Download PDF

Access Required
A Deburge
View article
Download PDF

GA Engh KA Dwyer CK Hanes
View article
Download PDF

We examined 86 polyethylene inserts, retrieved from total and unicompartmental knee prostheses after an average of 39.5 months in situ, grading them from 0 to 3 for seven modes of polyethylene degradation. Severe wear, with delamination or deformation, was observed in 51% of the implants, and was associated with time in situ, lack of congruency, thin polyethylene, third-body wear debris, and heat-pressed polyethylene. Significant under-surface cold flow was identified in some areas of unsupported polyethylene, and was associated with delamination in the load-bearing areas of thin inserts above screw holes in the underlying metal tray. We recommend the use of thicker polyethylene inserts, particularly in young, active patients and in designs with screw holes in the tibial baseplate. Thin polyethylene inserts which are at risk for accelerated wear and premature failure should be monitored radiographically at annual intervals.


SM Jones IM Pinder CG Moran AJ Malcolm
View article
Download PDF

Isolated wear of the polyethylene tibial component led to failure in five of a series of 108 uncemented porous-coated knee replacements. The clinical features included pain, effusion and instability with progressive varus deformity. In all cases there was extensive wear on the medial side of the polyethylene surface of the prosthesis. The mechanism of such wear is complex, being due in part to the unconstrained nature of the joint and the incongruity of its surfaces. Other design characteristics may have contributed.


JF Nolan TM Bucknill
View article
Download PDF

NP Coleman GJ Charnley NJ Goddard A Hashemi-Nejad
View article
Download PDF

Failure of an acetabular cup is uncommon and has been attributed to wear or creep, trauma or bony irregularities in the acetabulum. We report ten cases in which fracture of the cup occurred at the site of drill holes used to anchor the marker wire. The role of such indentations as stress raisers has not been previously reported; we suggest that deep indentations or grooves should not be placed in the most highly stressed areas and that the cup thickness should allow for predicted wear rates.


PJ Rubin PF Leyvraz JM Aubaniac JN Argenson P Esteve B de Roguin
View article
Download PDF

Biological fixation of cementless femoral implants requires primary stability by optimal fit in the proximal femur. The anatomy of the bone must then be known precisely. We analysed in vitro the accuracy of bone measurements of 32 femurs and compared the dimensions obtained from radiographs and CT scans with the true anatomical dimensions. Standard radiographs gave only a rough approximation of femoral geometry (mean difference: 2.4 +/- 1.4 mm) insufficiently accurate to allow selection of the best fitting prosthesis from a range of sizes and altogether inadequate to design a custom-made prosthesis. CT scans give greater accuracy (mean difference: 0.8 +/- 0.7 mm) in our experimental conditions, but in clinical practice additional sources of error exist.


Access Required
N Mitchell ER Lee N Shepard
View article
Download PDF

We studied the early cartilage changes in osteoarthritis, examining the most normal appearing articular cartilage from the hips of 17 patients. Normal appearing cartilage from five patients treated for fractures was used as control material. Two different types of clone were found. The first had increased staining for proteoglycan and was thought to have been engaged in the synthesis of matrix. The other type was associated with a severe deficiency of proteoglycan, matrix streaks and evidence of degradation and phagocytosis of matrix components. Immunohistochemistry demonstrated large amounts of chondroitin 4 and 6 sulphate about the synthetic-type clones, and little or no reactivity about the degenerative clones which lay more superficially and were associated with matrix destruction. Clones appeared to be engaged in either matrix synthesis or its destruction. The disease process of osteoarthritis appeared to begin at the surface of the articular cartilage.


Access Required
Shearer HI Roach SW Parsons
View article
Download PDF

We describe the histology of a specimen taken from an amputated leg seven months after a 15 cm bone gap in the tibia had been closed by bone transport. Lengthening appeared to have occurred by repeated minor trauma to the bone, with the fractured trabeculae in sufficiently close contact for the repair process to proceed. Osteogenesis did not occur through a cartilage phase, but the fracture gaps were bridged by collagen fibres, around which new bone formed. Microfractures had repaired by primary healing with woven bone and with no microcallus. Small regions of bone were necrotic. Resorption of the necrotic bone and remodelling of the immature bundle and woven bone were still at an early stage, suggesting that complete remodelling in man may take years rather than months.


MJ Fordyce RS Ling
View article
Download PDF

In a prospective, randomised controlled trial, the efficacy of the A-V Impulse System in the prevention of deep-vein thrombosis was investigated in 84 patients who had undergone total hip replacement. The incidence of venographically proven, and clinically significant postoperative deep-vein thrombosis was 40% in the control group and 5% in the treatment group (p less than 0.001). No adverse reactions were recorded.


NV Wilson SK Das VV Kakkar HD Maurice JG Smibert EM Thomas JE Nixon
View article
Download PDF

We performed a prospective randomised controlled trial of a new mechanical method of prophylaxis for venous thrombo-embolism in 60 patients undergoing knee replacement surgery. The method uses the A-V Impulse System to produce cyclical compression of the venous reservoir of the foot. The overall incidence of deep-vein thrombosis was 68.7% in patients receiving no prophylaxis and 50% in those using the device. The difference was not significant. There was, however, a reduction of the extent of thrombosis in the treated group. There were 13 major calf-vein thrombi and six proximal-vein thrombi in the control group compared with only five major calf-vein thrombi in the treated group. This difference was significant (p = 0.014). No patient developed clinical features of a pulmonary embolism.


A Wykman E Olsson
View article
Download PDF

We studied 50 patients before and after unilateral total hip replacement, and compared them, using gait analysis, with 22 having staged bilateral operations. The average age of the patients was 65 years at the first operation. The mean follow-up was 53 months for the unilateral cases and 27 months, after the second THR, for the bilateral cases. The average interval between first and second THR was 24 months. Patients with bilateral hip disease did not gain optimal function, even on the first side, until both hips had been replaced. Unilateral replacement gave better gait analysis results than did either side after bilateral procedures.


NA Athanasou J Quinn CJ Bulstrode
View article
Download PDF

The role of inflammatory cells in aseptic loosening and failure of cemented joint replacements is unclear. Inflammatory cells from the revision joint capsule of four failed hip arthroplasties were examined to determine their nature and resorptive capacity. The capsules contained numerous macrophages and abundant foreign-body macrophage polykaryons, distinguished from osteoclasts by their antigenic phenotype and lack of response to calcitonin. When cultured on cortical bone slices in vitro, both macrophages and macrophage polykaryons produced small resorption pits and were associated with areas of superficial resorption of the bone surface. These results indicate that foreign-body induced macrophages and macrophage polykaryons are capable of a type of low-grade bone resorption which may be of pathogenic significance in the loosening of cemented joint prosthetic components.


AC Campbell CH Rorabeck RB Bourne D Chess L Nott
View article
Download PDF

A retrospective review of 148 consecutive porous-coated hip arthroplasties (PCA) showed an incidence of thigh pain of 13% one year after surgery, and 22% at two years. Positive correlations were made with femoral stem subsidence (greater than 2 mm) and with distal periosteal and endosteal bone formation. No positive correlations were made with parameters of bone quality or component fit. Resolution of pain occurred in one-third and an anti-inflammatory agent produced partial relief in two-thirds of the patients. We conclude that thigh pain is secondary to stem instability with distal stress transfer in the absence of stable proximal fixation.


Access Required
LM Kwong M Jasty RD Mulroy WJ Maloney C Bragdon WH Harris
View article
Download PDF

The radiographic and histological features of radiolucent areas at the cement-bone interface were correlated in 15 specimens retrieved at post-mortem from patients who had undergone cemented total hip arthroplasty, two weeks to 15 years prior to death. All but one of the components were securely fixed, as demonstrated by direct measurements of micromotion. Extensive radiolucencies were present in all but one case. In 11 of the 14 specimens with radiolucencies, histological examination showed that the radiolucent areas represented regions of osteoporosis and bone remodelling. The remodelling changes were characterised by osteoporosis, cancellisation and thinning of the endosteal cortex, and osteopenia of the trabecular bone. In two specimens the appearance of radiolucency was found to be due to fibrous tissue at the cement-bone interface and in one specimen there was a mixed picture of osteolysis and fibrosis. The study demonstrates that radiolucent lines can occur with well-fixed components and that they may commonly represent osteoporosis rather than the presence of a fibrous membrane at the cement-bone interface.


PA Butler-Manuel SE James JA Shepperd
View article
Download PDF

A new method to reconstruct major acetabular floor defects is described. It relies on the placement of special nails into each of the three bones of the hemipelvis. Curved lugs attached to the nails are coalesced using bone cement forming a platform onto which a standard acetabular prosthesis is located. Forty-seven cases are reported with a mean follow-up of 4.4 years (1 to 8). No loosening of an acetabular cup or migration of the device has occurred.


SB Goksan MA Freeman
View article
Download PDF

One-stage reimplantation for the salvage of infected total knee arthroplasty in 18 patients was reviewed at an average follow-up of five years. There had been one recurrence and one new infection, both in rheumatoid patients with another focus of infection. In four other patients the clinical result was impaired by pain after walking (2) and limited flexion (2). Our results suggest that one-stage reimplantation is a reasonably reliable procedure for the management of a loose infected prosthesis.


YH Kim VE Kim
View article
Download PDF

We reviewed 82 primary arthroplasties (in 71 patients) in which cementless porous-coated hip prostheses were used. The mean age of the patients at operation was 52 years (24 to 86); they were followed up for an average of 62.1 months (60 to 66). The diagnosis was avascular necrosis of the femoral head in 35%, fracture of the femoral neck in 24%, primary osteoarthritis in 16% and miscellaneous in 25%. The average preoperative Harris hip score was 56.7 points and the average postoperative score was 83.3 points. Eight hips (10%) had component loosening; four had been revised and four were awaiting revision. In 27 hips (33%) there was a radiolucent line wider than 2 mm in zones 1 and 7. In 55 hips (67%) there was calcar resorption of more than 10 mm. Twenty patients (28%) complained of thigh pain although they had no radiographic evidence of loosening of a component. Factors that may have contributed to the poor clinical and radiographic results were: 1) inadequate surface area for bone ingrowth, particularly on the lateral aspect of the upper part of the prosthesis, 2) poor initial fit of the stem in the metaphysis, which resulted in cantilever motion of the proximal part of the stem about the well-fixed distal stem, and 3) the collar of the prosthesis, which prevented it from subsiding to a naturally stable position and caused damage to the calcar.


DJ Pemberton B McKibbin R Savage K Tayton D Stuart
View article
Download PDF

We report our experience with carbon-fibre reinforced plastic (CFRP) plates in the management of 19 problem fractures complicated by either infection, nonunion, comminution or contamination. The combination offers secure fixation without inhibition of callus formation.


M Liebergall J Lowe GP Whitelaw MJ Wetzler D Segal
View article
Download PDF

A consecutive series is reported of 17 patients who underwent early surgical treatment for acetabular or unstable pelvic fractures associated with ipsilateral fractures of the femur. Treatment included external and internal fixation, and required careful consideration of the surgical approach and the positioning of the patient. The multiple injuries sustained by these patients required simultaneous procedures by several surgical teams. All the femoral fractures were internally fixed at the initial operation and eight patients had primary definitive treatment of all their other fractures as well. In nine patients the definitive treatment of their other fractures was delayed for an average of 11 days. There were no deaths, and no serious infections. The long-term morbidity resulted from the associated injuries and not from the pelvic or femoral fractures.


G De Bastiani F Mosconi G Spagnol A Nicolato S Ferrari F Aprili
View article
Download PDF

We measured levels of calcitonin and other markers of calcium and phosphorus metabolism in both unconscious and conscious patients after multiple trauma. We found dramatic increases in calcitonin levels in unconscious patients, and smaller increases in conscious patients. In two cases, very high levels, more than 100 x normal, appeared to be related to more rapid healing of bone. Calcitonin levels were highest immediately after admission and decreased over the ensuing two weeks. The possible relationship between unconsciousness and the increased rate of healing of fractures is discussed.


RJ Beaver M Mahomed D Backstein A Davis DJ Zukor AE Gross
View article
Download PDF

Fresh osteochondral allografts were used to repair post-traumatic osteoarticular defects in 92 knees. At the time of grafting, varus or valgus deformities were corrected by upper tibial or supracondylar femoral osteotomies. A survivorship analysis was performed in which failure was defined as the need for a revision operation or the persistence of the pre-operative symptoms. There was a 75% success rate at five years, 64% at ten years and 63% at 14 years. The failure rate was higher for bipolar grafts than for unipolar and the results in patients over the age of 60 years were poor. The outcome did not depend on the sex of the patient and the results of allografts in the medial and lateral compartments of the knee were similar. Careful patient selection, correction of joint malalignment by osteotomy, and rigid fixation of the graft are all mandatory requirements for success. We recommend this method for the treatment of post-traumatic osteochondral defects in the knees of relatively young and active patients.


BW Scott WA Wallace MA Barton
View article
Download PDF

Four patients with pectoralis major ruptures underwent clinical and dynamometric assessment and one patient underwent late surgical repair. The operation is described. Dynamometry proved a useful and objective method of estimating the loss of strength and indicating patients who might benefit from surgical repair.


S Wagdy-Mahmoud AH Megahed OE el-Sheshtawy
View article
Download PDF

We report the use of a simple new technique for the repair of recent and old, neglected disruptions of the calcaneal tendon, which can be used where there is a wide gap. We reviewed 13 patients from one to six years after operation; all had good objective and subjective results. Four had minor skin complications.


A Hede E Larsen H Sandberg
View article
Download PDF

Two hundred patients with a meniscal lesion were peroperatively allocated to partial or total meniscectomy in a random manner. The results were compared at one year and at 6.3 to 9.8 years (median 7.8). After one year more patients with partial meniscectomy (90%) than with total meniscectomy (80%) had no complaints. At the later review these figures were 62% and 52%, respectively (p = 0.18). However, patients with partial meniscectomy had higher functional scores. The deterioration in function between the first review and the second showed no significant difference in the two treatment groups. The incidence of mediolateral instability rose from 8% to 47% and was more frequent after total than after partial meniscectomy. Between the two reviews the radiological signs of knee degeneration increased with no difference between the two treatment groups.


DJ Shewring BF Meggitt
View article
Download PDF

We report the results of treatment with the dynamic condylar screw of 21 cases of supracondylar and intercondylar fractures of the femur in patients aged 22 to 91 years. There were two nonunions and no deaths. We found the device easy to use and the good fixation allowed early patient mobilisation.


EJ Wall JB Massie MK Kwan BL Rydevik RR Myers Garfin
View article
Download PDF

We developed an animal model of stretch injury to nerve in order to study in vivo conduction changes as a function of nerve strain. In 24 rabbits, the tibial nerve was exposed and stretched by 0%, 6% or 12% of its length. The strain was maintained for one hour. Nerve conduction was monitored during the period of stretch and for a one-hour recovery period. At 6% strain, the amplitude of the action potential had decreased by 70% at one hour and returned to normal during the recovery period. At 12% strain, conduction was completely blocked by one hour, and showed minimal recovery. These findings have clinical implications in nerve repair, limb trauma, and limb lengthening.


N Maffulli T Hughes JA Fixsen
View article
Download PDF

Limb lengthening in nine patients was monitored by radiographs and by ultrasound scans. The distraction gap appeared as a sonolucent area within which echogenic foci developed soon after distraction commenced. By seven weeks a new cortex was detected, and medullary canal began to develop between seven and eight weeks. Ultrasound scanning can be used to measure distraction, but it was not as useful as radiographs in detecting angulation. Its use in patients undergoing limb lengthening could reduce their exposure to radiation.


PW Laing DI Cogley L Klenerman
View article
Download PDF

Ulceration of the insensitive foot continues to cause great morbidity in diabetic patients. We treated 46 patients with neuropathic ulceration by applying total contact casts. Most neuropathic ulcers healed within six weeks but ischaemic ulcers did not heal. One patient developed gangrene and required partial amputation of the foot.


TW Briggs P Smith TB McAuliffe
View article
Download PDF

We present the results of a prospective trial of osteotomy of the metatarsal neck for hallux valgus in 31 feet of 23 women, using a new stapling device with no plaster splintage and early weight-bearing. Surgery was performed for pain (29 feet) and difficulty with footwear (nine feet). The average time for return to light work was 3.3 weeks, and to full work 8.3 weeks after operation. Seventeen patients had full recovery within three months and 21 of the 23 patients had complete relief of pain. Shoes were more comfortable in 17 feet and 9 patients could wear narrower shoes. Only two patients were unsatisfied with the appearance of the foot. All the osteotomies united, and the average hallux valgus angle was improved on radiographs from 35 degrees to 23 degrees. The mean first metatarsal angle was reduced from 16 degrees to 11 degrees. The new technique allows more accurate surgery and easier postoperative management.


A Arnbjornsson N Egund O Rydling R Stockerup L Ryd
View article
Download PDF

From 1970 to 1978, 29 patients had a unilateral operation for bilateral recurrent dislocation of the patella. We examined 21 of them at a mean of 14 years postoperatively. Eighteen of these patients had evidence of generalised joint laxity. Six of the operated knees and four of the unoperated knees still had recurrent dislocations. The operated knees were clinically worse, with a significantly higher incidence of osteoarthritis. We concluded that the operations used to treat recurrent dislocation of the patella may have had short-term benefits, but did not cure the patients in the long term.


RK Fraser EB Hoffman LT Sparks SS Buccimazza
View article
Download PDF

We reviewed 55 patients with mid-lumbar myelomeningocele (L3 and L4) first seen over a 17-year period from 1970 to 1986 and followed up for an average of ten years. We assessed a number of factors which might affect hip stability and ability to walk, recording the natural history of clinical and radiological hip deformity. Two-thirds of the hips had become dislocated or subluxed by the end of the first year of life, involving 86% of hips in patients with an L3 level and 45% of those with an L4 level. All the hips that developed instability secondary to muscle imbalance did so within the first year. The neurological level was the most significant determinant of walking ability: all patients with L4 neurological levels could walk but only one-third of those with L3 lesions could do so. Hip stability, intelligence quotient and fixed deformity did not influence walking ability.


RT Ballock R Mackersie JJ Abitbol V Cervilla D Resnick Garfin
View article
Download PDF

Plain radiographs of 67 acute spinal compression fractures in 49 patients were analysed by subjective and objective criteria, using CT scans as the diagnostic standard for the diagnosis of burst fracture. Discriminant analysis correctly predicted the type of fracture in 88% of cases. Burst fractures, however, were almost as frequently misdiagnosed as being wedge compression fractures using this technique, compared with the reading of 25 films from patients without previous information. A quarter of the injuries would have been misdiagnosed had reliance been placed solely on the plain radiographs. CT scans of all patients with acute spinal compression fractures should be considered to decrease this potentially serious diagnostic error.


CH Brooks WJ Revell FW Heatley
View article
Download PDF

Previous perfusion studies of the rotator cuff have demonstrated an area of hypovascularity in the distal part of the supraspinatus tendon. This has been implicated in the pathogenesis of its rupture. We performed a quantitative histological analysis of the vascularity of the tendons of supraspinatus and infraspinatus. Vessel number, size and the percentage of the tendon occupied by vessels were measured at 5 mm intervals from the humeral insertions to the muscle bellies. Both tendons were hypovascular in their distal 15 mm. No significant difference was demonstrated between the vascularity of supraspinatus and infraspinatus. We conclude that factors other than vascularity are important in the pathogenesis of supraspinatus rupture.


Access Required
Hardy
View article
Download PDF

Access Required
F Postacchini D Perugia
View article
Download PDF

GA Pryor RN Villar N Coleman
View article
Download PDF

JL Bassi SC Ahuja H Singh
View article
Download PDF

JA Watson JP Hollingdale
View article
Download PDF

H Lacroix NA du Bois FC van Biezen
View article
Download PDF

Access Required
MJ Geppert M Sobel FM Thompson
View article
Download PDF

Access Required
R Kerr D Resnick
View article
Download PDF

Random blood salvage Pages 164 - 165
Access Required
H Fredin
View article
Download PDF

Use of tourniquets Pages 164 - 164
Access Required
A Edwards
View article
Download PDF