Advertisement for orthosearch.org.uk
Results 1 - 4 of 4
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 5 | Pages 776 - 776
1 Jul 2002
VAN NOORT A te SLAA RL MARTI RK VAN DER WERKEN C


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 6 | Pages 795 - 798
1 Aug 2001
van Noort A te Slaa RL Marti RK van der Werken C

The aim of this retrospective study was to review a series of patients with ipsilateral fractures of the neck of the scapula and of the clavicle. Between 1991 and 1996 a total of 79 general and orthopaedic surgeons treated 46 patients with a floating shoulder in The Netherlands. The records and radiographs of these patients were studied. Of the 35 patients available for follow-up, 31 had initially been treated conservatively and four by operation; three underwent secondary reconstructive surgery. The mean Constant score for the 28 patients treated conservatively was 76 and for the seven treated operatively it was 71 at a mean follow-up of 35 months. In six of the 28 patients treated conservatively the glenoid was dislocated caudally at the end of treatment; they had a score of 42. In the 22 patients without this dislocation the score was 85. We conclude that this rare injury is not inherently unstable and, in the absence of caudal dislocation of the glenoid, conservative treatment gives a good functional outcome.


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 5 | Pages 831 - 834
1 Sep 1996
Koot VCM Kesselaer SMMJ Clevers GJ de Hooge P Weits T van der Werken C

We studied the reliability of the Singh classification of trabecular bone structure in the proximal femur as a measure of osteoporosis, using kappa statistics. Radiographs of fractures of the femoral neck or trochanteric region in 80 consecutive patients were assessed by six observers. The interobserver variation was large; only three of 72 radiographs were given the same classification by all six observers and the kappa values ranged from 0.15 to 0.54. The intraobserver variation showed substantial strength of agreement; kappa values ranged from 0.63 to 0.88.

In 77 patients dual-energy X-ray absorptiometry was used to measure bone mineral density. The results were compared with those of the Singh classification: we found no correlation.


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 3 | Pages 395 - 399
1 May 1996
van Laarhoven CJHM Meeuwis JD van der Werken C

In a prospective, randomised trial of 81 patients with fractures of the ankle of AO types A, B and C we compared two regimes of postoperative management after internal fixation. The patients were mobilised either non-weight-bearing with crutches or weight-bearing in a below-knee walking plaster.

We found a temporary benefit in subjective evaluation only (65 v 50 points, Mann-Whitney test, cft, p = 0.02) for those with a below-knee walking plaster. There were no significant differences between the groups in the loaded dorsal range of movement (25° v 23°, Mann-Whitney test, cft, p = 0.16) or in the overall clinical result. Both treatments were considered to be satisfactory and their choice depends on the ability to mobilise non-weight-bearing, wound healing, the type of work and personal preference.