Advertisement for orthosearch.org.uk
Results 1 - 9 of 9
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1348 - 1360
1 Nov 2024
Spek RWA Smith WJ Sverdlov M Broos S Zhao Y Liao Z Verjans JW Prijs J To M Åberg H Chiri W IJpma FFA Jadav B White J Bain GI Jutte PC van den Bekerom MPJ Jaarsma RL Doornberg JN

Aims

The purpose of this study was to develop a convolutional neural network (CNN) for fracture detection, classification, and identification of greater tuberosity displacement ≥ 1 cm, neck-shaft angle (NSA) ≤ 100°, shaft translation, and articular fracture involvement, on plain radiographs.

Methods

The CNN was trained and tested on radiographs sourced from 11 hospitals in Australia and externally validated on radiographs from the Netherlands. Each radiograph was paired with corresponding CT scans to serve as the reference standard based on dual independent evaluation by trained researchers and attending orthopaedic surgeons. Presence of a fracture, classification (non- to minimally displaced; two-part, multipart, and glenohumeral dislocation), and four characteristics were determined on 2D and 3D CT scans and subsequently allocated to each series of radiographs. Fracture characteristics included greater tuberosity displacement ≥ 1 cm, NSA ≤ 100°, shaft translation (0% to < 75%, 75% to 95%, > 95%), and the extent of articular involvement (0% to < 15%, 15% to 35%, or > 35%).


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1150 - 1157
1 Oct 2024
de Klerk HH Verweij LPE Doornberg JN Jaarsma RL Murase T Chen NC van den Bekerom MPJ

Aims

This study aimed to gather insights from elbow experts using the Delphi method to evaluate the influence of patient characteristics and fracture morphology on the choice between operative and nonoperative treatment for coronoid fractures.

Methods

A three-round electronic (e-)modified Delphi survey study was performed between March and December 2023. A total of 55 elbow surgeons from Asia, Australia, Europe, and North America participated, with 48 completing all questionnaires (87%). The panellists evaluated the factors identified as important in literature for treatment decision-making, using a Likert scale ranging from "strongly influences me to recommend nonoperative treatment" (1) to "strongly influences me to recommend operative treatment" (5). Factors achieving Likert scores ≤ 2.0 or ≥ 4.0 were deemed influential for treatment recommendation. Stable consensus is defined as an agreement of ≥ 80% in the second and third rounds.


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1131 - 1131
1 Oct 2023
Macken AA Haagmans-Suman A Spekenbrink-Spooren A van Noort A van den Bekerom MPJ Eygendaal D Buijze GA


The Bone & Joint Journal
Vol. 105-B, Issue 9 | Pages 1000 - 1006
1 Sep 2023
Macken AA Haagmans-Suman A Spekenbrink-Spooren A van Noort A van den Bekerom MPJ Eygendaal D Buijze GA

Aims

The current evidence comparing the two most common approaches for reverse total shoulder arthroplasty (rTSA), the deltopectoral and anterosuperior approach, is limited. This study aims to compare the rate of loosening, instability, and implant survival between the two approaches for rTSA using data from the Dutch National Arthroplasty Registry with a minimum follow-up of five years.

Methods

All patients in the registry who underwent a primary rTSA between January 2014 and December 2016 using an anterosuperior or deltopectoral approach were included, with a minimum follow-up of five years. Cox and logistic regression models were used to assess the association between the approach and the implant survival, instability, and glenoid loosening, independent of confounders.


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 56 - 63
1 Jan 2023
de Klerk HH Oosterhoff JHF Schoolmeesters B Nieboer P Eygendaal D Jaarsma RL IJpma FFA van den Bekerom MPJ Doornberg JN

Aims

This study aimed to answer the following questions: do 3D-printed models lead to a more accurate recognition of the pattern of complex fractures of the elbow?; do 3D-printed models lead to a more reliable recognition of the pattern of these injuries?; and do junior surgeons benefit more from 3D-printed models than senior surgeons?

Methods

A total of 15 orthopaedic trauma surgeons (seven juniors, eight seniors) evaluated 20 complex elbow fractures for their overall pattern (i.e. varus posterior medial rotational injury, terrible triad injury, radial head fracture with posterolateral dislocation, anterior (trans-)olecranon fracture-dislocation, posterior (trans-)olecranon fracture-dislocation) and their specific characteristics. First, fractures were assessed based on radiographs and 2D and 3D CT scans; and in a subsequent round, one month later, with additional 3D-printed models. Diagnostic accuracy (acc) and inter-surgeon reliability (κ) were determined for each assessment.


The Bone & Joint Journal
Vol. 103-B, Issue 11 | Pages 1709 - 1716
1 Nov 2021
Sanders FRK Birnie MF Dingemans SA van den Bekerom MPJ Parkkinen M van Veen RN Goslings JC Schepers T

Aims

The aim of this study was to investigate whether on-demand removal (ODR) is noninferior to routine removal (RR) of syndesmotic screws regarding functional outcome.

Methods

Adult patients (aged above 17 years) with traumatic syndesmotic injury, surgically treated within 14 days of trauma using one or two syndesmotic screws, were eligible (n = 490) for inclusion in this randomized controlled noninferiority trial. A total of 197 patients were randomized for either ODR (retaining the syndesmotic screw unless there were complaints warranting removal) or RR (screw removed at eight to 12 weeks after syndesmotic fixation), of whom 152 completed the study. The primary outcome was functional outcome at 12 months after screw placement, measured by the Olerud-Molander Ankle Score (OMAS).


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 775 - 781
1 Apr 2021
Mellema JJ Janssen S Schouten T Haverkamp D van den Bekerom MPJ Ring D Doornberg JN

Aims

This study evaluated variation in the surgical treatment of stable (A1) and unstable (A2) trochanteric hip fractures among an international group of orthopaedic surgeons, and determined the influence of patient, fracture, and surgeon characteristics on choice of implant (intramedullary nailing (IMN) versus sliding hip screw (SHS)).

Methods

A total of 128 orthopaedic surgeons in the Science of Variation Group evaluated radiographs of 30 patients with Type A1 and A2 trochanteric hip fractures and indicated their preferred treatment: IMN or SHS. The management of Type A3 (reverse obliquity) trochanteric fractures was not evaluated. Agreement between surgeons was calculated using multirater kappa. Multivariate logistic regression models were used to assess whether patient, fracture, and surgeon characteristics were independently associated with choice of implant.


The Bone & Joint Journal
Vol. 99-B, Issue 2 | Pages 250 - 254
1 Feb 2017
Tol MCJM van den Bekerom MPJ Sierevelt IN Hilverdink EF Raaymakers ELFB Goslings JC

Aims

Our aim was to analyse the long-term functional outcome of two forms of surgical treatment for active patients aged > 70 years with a displaced intracapsular fracture of the femoral neck. Patients were randomised to be treated with either a hemiarthroplasty or a total hip arthroplasty (THA). The outcome five years post-operatively for this cohort has previously been reported. We present the outcome at 12 years post-operatively.

Patients and Methods

Initially 252 patients with a mean age of 81.1 years (70.2 to 95.6) were included, of whom 205 (81%) were women. A total of 137 were treated with a cemented hemiarthroplasty and 115 with a cemented THA. At long-term follow-up we analysed the modified Harris Hip Score (HHS), post-operative complications and intra-operative data of the patients who were still alive.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1422 - 1428
1 Oct 2010
van den Bekerom MPJ Hilverdink EF Sierevelt IN Reuling EMBP Schnater JM Bonke H Goslings JC van Dijk CN Raaymakers ELFB

The aim of this study was to analyse the functional outcome after a displaced intracapsular fracture of the femoral neck in active patients aged over 70 years without osteoarthritis or rheumatoid arthritis of the hip, randomised to receive either a hemiarthroplasty or a total hip replacement (THR). We studied 252 patients of whom 47 (19%) were men, with a mean age of 81.1 years (70.2 to 95.6). They were randomly allocated to be treated with either a cemented hemiarthroplasty (137 patients) or cemented THR (115 patients). At one- and five-year follow-up no differences were observed in the modified Harris hip score, revision rate of the prosthesis, local and general complications, or mortality. The intra-operative blood loss was lower in the hemiarthroplasty group (7% > 500 ml) than in the THR group (26% > 500 ml) and the duration of surgery was longer in the THR group (28% > 1.5 hours versus 12% > 1.5 hours). There were no dislocations of any bipolar hemiarthroplasty and eight dislocations of a THR during follow-up.

Because of a higher intra-operative blood loss (p < 0.001), an increased duration of the operation (p < 0.001) and a higher number of early and late dislocations (p = 0.002), we do not recommend THR as the treatment of choice in patients aged ≥ 70 years with a fracture of the femoral neck in the absence of advanced radiological osteoarthritis or rheumatoid arthritis of the hip.