Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1070 - 1075
1 Aug 2015
Murphy MT Vardi R Journeaux SF Whitehouse SL

If patients could recall their physical status before total hip (THA) or knee arthroplasty (TKA) accurately it could have valuable applications both clinically and for research. This study evaluated the accuracy of a patient’s recollection one year after either THA or TKA using the Oxford hip or knee scores (OHS and OKS). In total, 113 patients (59 THA, 54 TKA) who had completed the appropriate score pre-operatively were asked to complete the score again at a mean of 12.4 months (standard deviation (sd) 0.8) after surgery, recalling their pre-operative state.

While there were no significant differences between the actual and recalled pre-operative scores (OHS mean difference 0.8, sd 6.21, 95% confidence interval (CI) -0.82 to 2.42, p = 0.329; OKS mean difference -0.11, sd 7.34, 95% CI -2.11 to 1.89, p = 0.912), absolute differences were relatively large (OHS, 5.24; OKS, 5.41), correlation was weak (OHS r = 0.7, OKS r = 0.61) and agreement between actual and recalled responses for individual questions was poor in half of the OHS and two thirds of the OKS.

A patient’s recollection of pre-operative pain and function is inaccurate one year after THA or TKA.

Cite this article: Bone Joint J 2015;97-B:1070–5.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 5 | Pages 706 - 711
1 Jul 2003
Whitehouse SL Lingard EA Katz JN Learmonth ID

We used prospective data from 862 total knee and 716 total hip replacements three years after surgery in order to derive and validate a reduced Western Ontario and McMasters University Osteoarthritis Index (WOMAC) function scale. The reduced scale was derived using the advice of clinical experts as well as analysis of data. The scale was tested for validity, reliability and responsiveness.

Items which were retained included: ascending stairs, rising from sitting, walking on the flat, getting in or out of a car, putting on socks, rising from bed, and sitting.

The reduced and full scales had comparable, moderate correlations with other measures of function, confirming convergent validity. Cronbach’s alpha was high (α > 0.85) with the reduced scale confirming reliability. Responsiveness was greater for the reduced scale (full = 1.4, reduced = 1.6).

This reduced version of the WOMAC function scale provides a practical, valid, reliable and responsive alternative to the full function scale for use after total joint replacement. Further work is needed to demonstrate its wider applicability.