Advertisement for orthosearch.org.uk
Results 1 - 20 of 54
Results per page:
Bone & Joint Research
Vol. 13, Issue 11 | Pages 632 - 646
7 Nov 2024
Diaz Dilernia F Watson D Heinrichs DE Vasarhelyi E

Aims

The mechanism by which synovial fluid (SF) kills bacteria has not yet been elucidated, and a better understanding is needed. We sought to analyze the antimicrobial properties of exogenous copper in human SF against Staphylococcus aureus.

Methods

We performed in vitro growth and viability assays to determine the capability of S. aureus to survive in SF with the addition of 10 µM of copper. We determined the minimum bactericidal concentration of copper (MBC-Cu) and evaluated its sensitivity to killing, comparing wild type (WT) and CopAZB-deficient USA300 strains.


Bone & Joint Open
Vol. 4, Issue 8 | Pages 551 - 558
1 Aug 2023
Thomas J Shichman I Ohanisian L Stoops TK Lawrence KW Ashkenazi I Watson DT Schwarzkopf R

Aims

United Classification System (UCS) B2 and B3 periprosthetic fractures in total hip arthroplasties (THAs) have been commonly managed with modular tapered stems. No study has evaluated the use of monoblock fluted tapered titanium stems for this indication. This study aimed to evaluate the effects of a monoblock stems on implant survivorship, postoperative outcomes, radiological outcomes, and osseointegration following treatment of THA UCS B2 and B3 periprosthetic fractures.

Methods

A retrospective review was conducted of all patients who underwent revision THA (rTHA) for periprosthetic UCS B2 and B3 periprosthetic fracture who received a single design monoblock fluted tapered titanium stem at two large, tertiary care, academic hospitals. A total of 72 patients met inclusion and exclusion criteria (68 UCS B2, and four UCS B3 fractures). Primary outcomes of interest were radiological stem subsidence (> 5 mm), radiological osseointegration, and fracture union. Sub-analysis was also done for 46 patients with minimum one-year follow-up.


Bone & Joint Research
Vol. 10, Issue 10 | Pages 650 - 658
1 Oct 2021
Sanghani-Kerai A Black C Cheng SO Collins L Schneider N Blunn G Watson F Fitzpatrick N

Aims

This study investigates the effects of intra-articular injection of adipose-derived mesenchymal stem cells (AdMSCs) and platelet-rich plasma (PRP) on lameness, pain, and quality of life in osteoarthritic canine patients.

Methods

With informed owner consent, adipose tissue collected from adult dogs diagnosed with degenerative joint disease was enzymatically digested and cultured to passage 1. A small portion of cells (n = 4) surplus to clinical need were characterized using flow cytometry and tri-lineage differentiation. The impact and degree of osteoarthritis (OA) was assessed using the Liverpool Osteoarthritis in Dogs (LOAD) score, Modified Canine Osteoarthritis Staging Tool (mCOAST), kinetic gait analysis, and diagnostic imaging. Overall, 28 joints (25 dogs) were injected with autologous AdMSCs and PRP. The patients were followed up at two, four, eight, 12, and 24 weeks. Data were analyzed using two related-samples Wilcoxon signed-rank or Mann-Whitney U tests with statistical significance set at p < 0.05.


The Bone & Joint Journal
Vol. 98-B, Issue 9 | Pages 1202 - 1207
1 Sep 2016
Jeyaseelan L Chandrashekar S Mulligan A Bosman HA Watson AJS

Aims

The mainstay of surgical correction of hallux valgus is first metatarsal osteotomy, either proximally or distally. We present a technique of combining a distal chevron osteotomy with a proximal opening wedge osteotomy, for the correction of moderate to severe hallux valgus.

Patients and Methods

We reviewed 45 patients (49 feet) who had undergone double osteotomy. Outcome was assessed using the American Orthopaedic Foot and Ankle Society (AOFAS) and the Short Form (SF) -36 Health Survey scores. Radiological measurements were undertaken to assess the correction.

The mean age of the patients was 60.8 years (44.2 to 75.3). The mean follow-up was 35.4 months (24 to 51).


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1107 - 1112
1 Aug 2012
Bugler KE Watson CD Hardie AR Appleton P McQueen MM Court-Brown CM White TO

Techniques for fixation of fractures of the lateral malleolus have remained essentially unchanged since the 1960s, but are associated with complication rates of up to 30%. The fibular nail is an alternative method of fixation requiring a minimal incision and tissue dissection, and has the potential to reduce the incidence of complications.

We reviewed the results of 105 patients with unstable fractures of the ankle that were fixed between 2002 and 2010 using the Acumed fibular nail. The mean age of the patients was 64.8 years (22 to 95), and 80 (76%) had significant systemic medical comorbidities. Various different configurations of locking screw were assessed over the study period as experience was gained with the device. Nailing without the use of locking screws gave satisfactory stability in only 66% of cases (4 of 6). Initial locking screw constructs rendered between 91% (10 of 11) and 96% (23 of 24) of ankles stable. Overall, seven patients had loss of fixation of the fracture and there were five post-operative wound infections related to the distal fibula. This lead to the development of the current technique with a screw across the syndesmosis in addition to a distal locking screw. In 21 patients treated with this technique there have been no significant complications and only one superficial wound infection. Good fracture reduction was achieved in all of these patients. The mean physical component Short-Form 12, Olerud and Molander score, and American Academy of Orthopaedic Surgeons Foot and Ankle outcome scores at a mean of six years post-injury were 46 (28 to 61), 65 (35 to 100) and 83 (52 to 99), respectively. There have been no cases of fibular nonunion.

Nailing of the fibula using our current technique gives good radiological and functional outcomes with minimal complications, and should be considered in the management of patients with an unstable ankle fracture.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 8 | Pages 1033 - 1044
1 Aug 2011
Periasamy K Watson WS Mohammed A Murray H Walker B Patil S Meek RMD

The ideal acetabular component is characterised by reliable, long-term fixation with physiological loading of bone and a low rate of wear. Trabecular metal is a porous construct of tantalum which promotes bony ingrowth, has a modulus of elasticity similar to that of cancellous bone, and should be an excellent material for fixation.

Between 2004 and 2006, 55 patients were randomised to receive either a cemented polyethylene or a monobloc trabecular metal acetabular component with a polyethylene articular surface. We measured the peri-prosthetic bone density around the acetabular components for up to two years using dual-energy x-ray absorptiometry.

We found evidence that the cemented acetabular component loaded the acetabular bone centromedially whereas the trabecular metal monobloc loaded the lateral rim and behaved like a hemispherical rigid metal component with regard to loading of the acetabular bone. We suspect that this was due to the peripheral titanium rim used for the mechanism of insertion.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 5 | Pages 693 - 700
1 May 2010
Makki D Alnajjar HM Walkay S Ramkumar U Watson AJ Allen PW

We carried out a retrospective review of 47 intra-articular fractures of the calcaneum treated by open reduction and internal fixation in 45 patients by a single surgeon between 1993 and 2001. The fractures were evaluated before operation by plain radiographs and a CT scan using Sanders’ classification. Osteosynthesis involved a lateral approach and the use of the AO calcaneal plate. The mean follow-up was for ten years (7 to 15). Clinical assessment included the American Orthopaedic Foot and Ankle Society Score (AOFAS), the Creighton-Nebraska Score, the Kerr, Prothero, Atkins Score and the SF-36 Health Questionnaire. The radiological evaluation consisted of lateral and axial views of the os calcis. Arthritic changes in the subtalar joint were assessed with an internal oblique view and were graded using the Morrey and Wiedeman scale.

There were 18 excellent (38.3%), 17 good (36.2%), three fair (6.3%) and nine poor (19.2%) results. Five patients had a superficial wound infection and five others eventually had a subtalar arthrodesis because of continuing pain. Restoration of Böhler’s angle was associated with a better outcome. The degree of arthritic change in the subtalar joint did not correlate with the outcome scores or Sanders’ classification. Prompt osteosynthesis should be considered for intra-articular fractures of the calcaneum in order to restore the shape of the hindfoot and Böhler’s angle.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 4 | Pages 451 - 454
1 Apr 2008
Amin A Watson A Mangwani J Nawabi DH Ahluwalia R Loeffler M

We undertook a prospective randomised controlled trial to investigate the efficacy of autologous retransfusion drains in reducing the need for allogenic blood requirement after unilateral total knee replacement. We also monitored the incidence of post-operative complications. There were 86 patients in the control group, receiving standard care with a vacuum drain, and 92 who received an autologous drain and were retransfused postoperatively. Following serial haemoglobin measurements at 24, 48 and 72 hours, we found no difference in the need for allogenic blood between the two groups (control group 15.1%, retransfusion group 13% (p = 0.439)). The incidence of post-operative complications, such as wound infection, deep-vein thrombosis and chest infection, was also comparable between the groups. There were no adverse reactions associated with the retransfusion of autologous blood.

Based on this study, the cost-effectiveness and continued use of autologous drains in total knee replacement should be questioned.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1158 - 1164
1 Sep 2007
Lusty PJ Watson A Tuke MA Walter WL Walter WK Zicat B

We studied 33 third generation, alumina ceramic-on-ceramic bearings retrieved from cementless total hip replacements after more than six months in situ. Wear volume was measured with a Roundtest machine, and acetabular orientation from the anteroposterior pelvic radiograph. The overall median early wear rate was 0.1 mm3/yr for the femoral heads, and 0.04 mm3/yr for the acetabular liners. We then excluded hips where the components had migrated. In this stable subgroup of 22 bearings, those with an acetabular anteversion of < 15° (seven femoral heads) had a median femoral head wear rate of 1.2 mm3/yr, compared with 0 mm3/yr for those with an anteversion of ≥15° (15 femoral heads, p < 0.001). Even under edge loading, wear volumes with ceramic-on-ceramic bearings are small in comparison to other bearing materials. Low acetabular anteversion is associated with greater wear.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 5 | Pages 606 - 613
1 May 2006
Abu-Rajab RB Watson WS Walker B Roberts J Gallacher SJ Meek RMD

We compared peri-prosthetic bone mineral density between identical cemented and cementless LCS rotating platform total knee arthroplasties. Two matched cohorts had dual energy x-ray absorptiometry scans two years post-operatively using a modified validated densitometric analysis protocol, to assess peri-prosthetic bone mineral density. The knee that was not operated on was also scanned to enable the calculation of a relative bone mineral density difference. Oxford Knee and American Knee Society scores were comparable in the two cohorts.

Statistical analysis revealed no significant difference in absolute, or relative peri-prosthetic bone mineral density with respect to the method of fixation. However, the femoral peri-prosthetic bone mineral density and relative bone mineral density difference were significantly decreased, irrespective of the method of fixation, particularly in the anterior distal portion of the femur, with a mean reduction in relative bone mineral density difference of 27%.

There was no difference in clinical outcome between the cemented and cementless LCS total knee arthroplasty. However, both produce stress-shielding around the femoral implants. This leads us to question the use of more expensive cementless total knee components.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 3 | Pages 406 - 410
1 Mar 2006
Quinlan JF Watson RWG Kelly G Kelly PM O’Byrne JM Fitzpatrick JM

Injuries to the spinal cord may be associated with increased healing of fractures. This can be of benefit, but excessive bone growth can also cause considerable adverse effects.

We evaluated two groups of patients with fractures of the spinal column, those with neurological compromise (n = 10) and those without (n = 15), and also a control group with an isolated fracture of a long bone (n = 12). The level of transforming growth factor-beta (TGF-β), was measured at five time points after injury (days 1, 5, 10, 42 and 84).

The peak level of 142.79 ng/ml was found at day 84 in the neurology group (p < 0.001 vs other time points). The other groups peaked at day 42 and had a decrease at day 84 after injury (p ≤ 0.001).

Our findings suggest that TGF-β may have a role in the increased bone turnover and attendant complications seen in patients with acute injuries to the spinal cord.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 2 | Pages 211 - 215
1 Mar 2002
Bayat A Watson JS Stanley JK Alansari A Shah M Ferguson MWJ Ollier WER

Dupuytren’s disease is a benign fibroproliferative disease of unknown aetiology. It is often familial and commonly affects Northern European Caucasian men, but genetic studies have yet to identify the relevant genes.

Transforming growth factor beta one (TGF-β1) is a multifunctional cytokine which plays a central role in wound healing and fibrosis. It stimulates the proliferation of fibroblasts and the deposition of extracellular matrix. Previous studies have implicated TGF-β1 in Dupuytren’s disease, suggesting that it may represent a candidate susceptibility gene for this condition.

We have investigated the association of four common single nucleotide polymorphisms in TGF-β1 with the risk of developing Dupuytren’s disease. A polymerase chain reaction-restriction fragment length polymorphism method was used for genotyping TGF-β1 polymorphisms. DNA samples from 135 patients with Dupuytren’s disease and 200 control subjects were examined.

There was no statistically significant difference in TGF-β1 genotype or allele frequency distributions between the patients and controls for the codons 10, 25, −509 and −800 polymorphisms.

Our observations suggest that common TGF-β1 polymorphisms are not associated with a risk of developing Dupuytren’s disease. These data should be interpreted with caution since the lack of association was shown in only one series of patients with only known, common polymorphisms of TGF-β1. To our knowledge, this is the first report of a case-control association study in Dupuytren’s disease using single nucleotide polymorphisms in TGF-β1.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 2 | Pages 196 - 201
1 Mar 2002
Burke JG Watson RWG McCormack D Dowling FE Walsh MG Fitzpatrick JM

Herniated intervertebral disc tissue has been shown to produce a number of proinflammatory mediators and cytokines, but there have been no similar studies using discs from patients with discogenic low back pain.

We have compared the levels of production of interleukin-6 (IL-6), interleukin-8 (IL-8) and prostaglandin E2 (PGE2) in disc tissue from patients undergoing discectomy for sciatica (63) with that from patients undergoing fusion for discogenic low back pain (20) using an enzyme-linked immunoabsorbent assay.

There was a statistically significant difference between levels of production of IL-6 and IL-8 in the sciatica and low back pain groups (p < 0.006 and p < 0.003, respectively).

The high levels of proinflammatory mediator found in disc tissue from patients undergoing fusion suggest that production of proinflammatory mediators within the nucleus pulposus may be a major factor in the genesis of a painful lumbar disc.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 3 | Pages 465 - 465
1 Apr 2000
Watson M


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 1 | Pages 184 - 184
1 Jan 1999
Watson MS


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 1 | Pages 124 - 127
1 Jan 1996
Watson M

A bipolar spacer was inserted for severe arthritic destruction of the shoulder in 14 patients, and followed up for a mean of 5.9 years. In one patient the operation failed because of infection. Two others required revision for loss of low-friction properties which caused loosening of the humeral component.

At the end of the follow-up all the patients showed improvement. The Hospital for Special Surgery pain score had increased from 5.3 to 18.9 and the movement score from 7.5 to 20.1.


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 6 | Pages 951 - 954
1 Nov 1994
Vangsness C Jorgenson S Watson T Johnson D

We dissected 105 cadaveric shoulders to study the origin of the tendon of the long head of biceps, and examined histologically the interrelationship between the tendon, the supraglenoid tubercle and the superior labrum of the glenoid. In all specimens approximately 50% of the biceps tendon arose directly from the superior glenoid labrum with the remainder attached to the supraglenoid tubercle. The main labral origin was from the posterior labrum in more than half of the specimens, and in a quarter this was the only labral attachment. On the basis of the biceps attachment to the anterior or posterior labrum, we distinguished four types of origin. These normal anatomical variations are significant for arthroscopic diagnosis and may help to explain the various patterns of injury seen in partial or complete detachment of the tendon, the labrum or both.


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 5 | Pages 750 - 753
1 Sep 1994
Adam R Watson S Jarratt J Noble J Watson J

The long-term functional result of exposed total knee arthroplasty, treated by flap cover, is presented and the results compared with those of a randomly selected control group. The wound was successfully covered and the prosthesis was preserved in 76% of cases, but the final functional score was not as good as in those with primary wound healing.


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 1 | Pages 158 - 159
1 Jan 1992
Watson J Hollingdale J


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 3 | Pages 418 - 422
1 May 1990
Nicholas R Orr J Mollan R Calderwood J Nixon Watson P

Augmentation of the acetabular component of total hip replacements is a method of increasing stability and preventing recurrent dislocation. We report a series of mechanical experiments designed to evaluate the turning moments and angles required to dislocate standard, long posterior wall and two different augmented prostheses.