To explore the efficacy of extracorporeal shockwave therapy (ESWT) in the treatment of osteochondral defect (OCD), and its effects on the levels of transforming growth factor (TGF)-β, bone morphogenetic protein (BMP)-2, -3, -4, -5, and -7 in terms of cartilage and bone regeneration. The OCD lesion was created on the trochlear groove of left articular cartilage of femur per rat (40 rats in total). The experimental groups were Sham, OCD, and ESWT (0.25 mJ/mm2, 800 impulses, 4 Hz). The animals were euthanized at 2, 4, 8, and 12 weeks post-treatment, and histopathological analysis, micro-CT scanning, and immunohistochemical staining were performed for the specimens.Aims
Methods
This study aimed to establish the optimal fixation methods for calcaneal tuberosity avulsion fractures with different fragment thicknesses in a porcine model. A total of 36 porcine calcanea were sawed to create simple avulsion fractures with three different fragment thicknesses (5, 10, and 15 mm). They were randomly fixed with either two suture anchors or one headless screw. Load-to-failure and cyclic loading tension tests were performed for the biomechanical analysis.Aims
Methods
The aim of this study was to assess the safety and clinical outcome of patients with a femoral shaft fracture and a previous complex post-traumatic femoral malunion who were treated with a clamshell osteotomy and fixation with an intramedullary nail (IMN). The study involved a retrospective analysis of 23 patients. All had a previous, operatively managed, femoral shaft fracture with malunion due to hardware failure. They were treated with a clamshell osteotomy between May 2015 and March 2020. The mean age was 42.6 years (26 to 62) and 15 (65.2%) were male. The mean follow-up was 2.3 years (1 to 5). Details from their medical records were analyzed. Clinical outcomes were assessed using the quality of correction of the deformity, functional recovery, the healing time of the fracture, and complications.Aims
Methods
Pellino1 (Peli1) has been reported to regulate various inflammatory diseases. This study aims to explore the role of Peli1 in the occurrence and development of osteoarthritis (OA), so as to find new targets for the treatment of OA. After inhibiting Peli1 expression in chondrocytes with small interfering RNA (siRNA), interleukin (IL)-1β was used to simulate inflammation, and OA-related indicators such as synthesis, decomposition, inflammation, and apoptosis were detected. Toll-like receptor (TLR) and nuclear factor-kappa B (NF-κB) signalling pathway were detected. After inhibiting the expression of Peli1 in macrophages Raw 264.7 with siRNA and intervening with lipopolysaccharide (LPS), the polarization index of macrophages was detected, and the supernatant of macrophage medium was extracted as conditioned medium to act on chondrocytes and detect the apoptosis index. The OA model of mice was established by destabilized medial meniscus (DMM) surgery, and adenovirus was injected into the knee cavity to reduce the expression of Peli1. The degree of cartilage destruction and synovitis were evaluated by haematoxylin and eosin (H&E) staining, Safranin O/Fast Green staining, and immunohistochemistry.Aims
Methods
Osteoarthritis (OA) is a common degenerative joint disease characterized by chronic inflammatory articular cartilage degradation. Long noncoding RNAs (lncRNAs) have been previously indicated to play an important role in inflammation-related diseases. Herein, the current study set out to explore the involvement of lncRNA H19 in OA. Firstly, OA mouse models and interleukin (IL)-1β-induced mouse chondrocytes were established. Expression patterns of IL-38 were determined in the synovial fluid and cartilage tissues from OA patients. Furthermore, the targeting relationship between lncRNA H19, tumour protein p53 (TP53), and IL-38 was determined by means of dual-luciferase reporter gene, chromatin immunoprecipitation, and RNA immunoprecipitation assays. Subsequent to gain- and loss-of-function assays, the levels of cartilage damage and proinflammatory factors were further detected using safranin O-fast green staining and enzyme-linked immunosorbent assay (ELISA) in vivo, respectively, while chondrocyte apoptosis was measured using Terminal deoxynucleotidyl transferase dUTP Nick-End Labeling (TUNEL) in vitro.Aims
Methods
The purpose of this study was to validate our hypothesis that centrifugation may eliminate false-positive leucocyte esterase (LE) strip test results caused by autoimmune diseases in the diagnosis of knee infection. Between January 2016 and May 2019, 83 cases, including 33 cases of septic arthritis and 50 cases of aseptic arthritis, were enrolled in this study. To further validate our hypothesis, another 34 cases of inflammatory arthritis from the Department of Rheumatology of our institution were also included. After aspiration, one drop of synovial fluid was applied to LE strips before and after centrifugation. The results were recorded after approximately three minutes according to the different colour grades on the colour chart. The differences of LE results between each cohort were analyzed.Aims
Methods
MicroRNAs (miRNAs) have been reported as key regulators of bone formation, signalling, and repair. Fracture healing is a proliferative physiological process where the body facilitates the repair of a bone fracture. The aim of our study was to explore the effects of microRNA-186 (miR-186) on fracture healing through the bone morphogenetic protein (BMP) signalling pathway by binding to Smad family member 6 (SMAD6) in a mouse model of femoral fracture. Microarray analysis was adopted to identify the regulatory miR of SMAD6. 3D micro-CT was performed to assess the bone volume (BV), bone volume fraction (BVF, BV/TV), and bone mineral density (BMD), followed by a biomechanical test for maximum load, maximum radial degrees, elastic radial degrees, and rigidity of the femur. The positive expression of SMAD6 in fracture tissues was measured. Moreover, the miR-186 level, messenger RNA (mRNA) level, and protein levels of SMAD6, BMP-2, and BMP-7 were examined.Objectives
Methods
The aim of this study was to describe the technique of distraction
osteogenesis followed by arthrodesis using internal fixation to
manage complex conditions of the ankle, and to present the results
of this technique. Between 2008 and 2014, distraction osteogenesis followed by arthrodesis
using internal fixation was performed in 12 patients with complex
conditions of the ankle due to trauma or infection. There were eight
men and four women: their mean age was 35 years (23 to 51) at the
time of surgery. Bone healing and functional recovery were evaluated
according to the criteria described by Paley. Function was assessed
using the ankle-hindfoot scale of the American Orthopedic Foot and
Ankle Society (AOFAS).Aims
Patients and Methods
We conducted a study to identify factors that are prognostic
of the outcome of extracorporeal shockwave therapy (ESWT) for calcific
tendinitis of the shoulder. Since 1998, patients with symptomatic calcific tendinitis of
the rotator cuff have been treated with ESWT using an electrohydraulic
mode shockwave device. One year after ESWT, patients were grouped
according to the level of resorption of calcification.Aims
Patients and Methods
Minimally invasive transforaminal lumbar interbody fusion (MITLIF)
has been well validated in overweight and obese patients who are
consequently subject to a higher radiation exposure. This prospective
multicentre study aimed to investigate the efficacy of a novel lumbar
localisation system for MITLIF in overweight patients. The initial study group consisted of 175 patients. After excluding
49 patients for various reasons, 126 patients were divided into
two groups. Those in Group A were treated using the localisation
system while those in Group B were treated by conventional means.
The primary outcomes were the effective radiation dosage to the
surgeon and the exposure time.Aims
Patients and Methods
This study compared the long-term results following Salter osteotomy
and Pemberton acetabuloplasty in children with developmental dysplasia
of the hip (DDH). We assessed if there was a greater increase in
pelvic height following the Salter osteotomy, and if this had a
continued effect on pelvic tilt, lumbar curvature or functional outcomes. We reviewed 42 children at more than ten years post-operatively
following a unilateral Salter osteotomy or Pemberton acetabuloplasty.
We measured the increase in pelvic height and the iliac crest tilt
and sacral tilt at the most recent review and at an earlier review
point in the first decade of follow-up. We measured the lumbar Cobb angle
and the Short Form-36 (SF-36) and Harris hip scores were collected
at the most recent review.Aims
Patients and Methods
The objective of this study was to evaluate the rotation and
translation of each joint in the hindfoot and compare the load response
in healthy feet with that in stage II posterior tibial tendon dysfunction
(PTTD) flatfoot by analysing the reconstructive three-dimensional
(3D) computed tomography (CT) image data during simulated weight-bearing. CT scans of 15 healthy feet and 15 feet with stage II PTTD flatfoot
were taken first in a non-weight-bearing condition, followed by
a simulated full-body weight-bearing condition. The images of the
hindfoot bones were reconstructed into 3D models. The ‘twice registration’
method in three planes was used to calculate the position of the
talus relative to the calcaneus in the talocalcaneal joint, the
navicular relative to the talus in talonavicular joint, and the cuboid
relative to the calcaneus in the calcaneocuboid joint.Objective
Methods
Although the importance of lateral femoral wall
integrity is increasingly being recognised in the treatment of intertrochanteric
fracture, little attention has been put on the development of a
secondary post-operative fracture of the lateral wall. Patients
with post-operative fractures of the lateral wall were reported
to have high rates of re-operation and complication. To date, no
predictors of post-operative lateral wall fracture have been reported.
In this study, we investigated the reliability of lateral wall thickness
as a predictor of lateral wall fracture after dynamic hip screw
(DHS) implantation. A total of 208 patients with AO/OTA 31-A1 and -A2 classified
intertrochanteric fractures who received internal fixation with
a DHS between January 2003 and May 2012 were reviewed. There were
103 men and 150 women with a mean age at operation of
78 years (33 to 94). The mean follow-up was 23 months (6 to 83).
The right side was affected in 97 patients and the left side in
111. Clinical information including age, gender, side, fracture
classification, tip–apex distance, follow-up time, lateral wall
thickness and outcome were recorded and used in the statistical
analysis. Fracture classification and lateral wall thickness significantly
contributed to post-operative lateral wall fracture (both p <
0.001). The lateral wall thickness threshold value for risk of developing
a secondary lateral wall fracture was found to be 20.5 mm. To our knowledge, this is the first study to investigate the
risk factors of post-operative lateral wall fracture in intertrochanteric
fracture. We found that lateral wall thickness was a reliable predictor
of post-operative lateral wall fracture and conclude that intertrochanteric
fractures with a lateral wall thickness <
20.5 mm should not
be treated with DHS alone. Cite this article:
It is difficult to determine the safe timing
of weight-bearing or reconstructive surgery in patients with Charcot arthropathy
of the foot and ankle. In this study the Doppler spectrum of the
first dorsal metatarsal artery was used to monitor the activity
of the disease activity and served as a guideline for management.
A total of 15 patients (seven men and eight women) with acute diabetic
Charcot arthropathy of the foot and ankle were immobilised in a non-weight-bearing
cast. They were followed at two-week intervals and bilateral Doppler
spectra of the first dorsal metatarsal arteries were obtained using
a 10 MHz linear ultrasound probe. The patients were allowed to start weight-bearing
or undergo surgery after the Doppler spectrum had returned to normal
pattern. The Doppler spectra in the unaffected limbs were triphasic
in pattern, whereas those in limbs with active Charcot arthropathy
showed monophasic forward flow. They returned to normal after a
mean of 13.6 weeks (6 to 20) of immobilisation. Three patients underwent
pan-talar arthrodesis to correct gross instability and deformity. Doppler spectrum analysis of the foot may reflect the activity
of the disease in patients with Charcot arthropathy, and may be
used as a guide to begin weight-bearing or undergo reconstructive
surgery.
Intra-articular resection of bone with soft-tissue balancing and total knee replacement (TKR) has been described for the treatment of patients with severe osteoarthritis of the knee associated with an ipsilateral malunited femoral fracture. However, the extent to which deformity in the sagittal plane can be corrected has not been addressed. We treated 12 patients with severe arthritis of the knee and an extra-articular malunion of the femur by TKR with intra-articular resection of bone and soft-tissue balancing. The femora had a mean varus deformity of 16° (8° to 23°) in the coronal plane. There were seven recurvatum deformities with a mean angulation of 11° (6° to 15°) and five antecurvatum deformities with a mean angulation of 12° (6° to 15°). The mean follow-up was 93 months (30 to 155). The median Knee Society knee and function scores improved from 18.7 (0 to 49) and 24.5 (10 to 50) points pre-operatively to 93 (83 to 100) and 90 (70 to 100) points at the time of the last follow-up, respectively. The mean mechanical axis of the knee improved from 22.6° of varus (15° to 27° pre-operatively to 1.5° of varus (3° of varus to 2° of valgus) at the last follow-up. The recurvatum deformities improved from a mean of 11° (6° to 15°) pre-operatively to 3° (0° to 6°) at the last follow-up. The antecurvatum deformities in the sagittal plane improved from a mean of 12° (6° to 16°) pre-operatively to 4.4° (0° to 8°) at the last follow-up. Apart from varus deformities, TKR with intra-articular bone resection effectively corrected the extra-articular deformity of the femur in the presence of antecurvatum of up to 16° and recurvatum of up to 15°.
We investigated the outcome of deep-vein thrombosis (DVT) in the calf after total knee arthroplasty (TKA) in 48 patients (45 women and three men) by clinical assessment and venographic study between three and four years after surgery. The mean age of the patients was 67.2 ± 7.7 years (52 to 85) and the mean follow-up was 42.6 ± 2.7 months (38 to 48). The diagnosis was osteoarthritis in 47 patients and rheumatoid arthritis in one patient. There were 44 calf thrombi, four popliteal thrombi but no thrombi in the femoral or iliac regions. Of the 48 patients, 24 were clinically symptomatic and 24 were asymptomatic. Clinical examination was carried out on 41 patients, of whom 37 underwent ascending venography. Seven were evaluated by telephone interview. No patient had the symptoms or signs of recurrent DVT, venous insufficiency in the affected leg, or a history of pulmonary embolism. No patient had been treated for complications of their DVT. Thirty-six of the 37 venographic studies were negative for either old or new DVT in the affected leg. One patient had residual thrombi in the muscular branches of the veins. Our study shows that deep-vein thromboses in the calf after TKA disappear spontaneously with time. No patient developed a recurrent DVT, proximal propagation or embolisation. Treatment of DVT in the calf after TKA should be based on the severity of the symptoms during the immediate postoperative period.
We compared the mechanical properties of normal and reconstructed heel pads in seven patients. Four had latissimus dorsi flaps and one each an anterior thigh flap, a local dorsalis pedis flap and a sural arterial flap. The thickness of the heel pad was measured under serial incremental loads of 0.5 kg to a maximum of 3 kg and then relaxed sequentially. The load-displacement curve of the heel pad during a loading-unloading cycle was plotted and from this the unloaded heel-pad thickness (UHPT), compressibility index (CI), elastic modulus (Ep), and energy dissipation ratio (EDR) were calculated. The EDR was significantly increased in the reconstructed heels (53.7 ± 18%