header advert
Results 1 - 8 of 8
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 1 | Pages 4 - 5
1 Jan 1993
Stoker D


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 6 | Pages 934 - 934
1 Nov 1992
Stoker D


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 3 | Pages 498 - 500
1 May 1991
Stoker D Cobb J Pringle J

Needle biopsies, performed on 208 consecutive patients and interpreted at the London Bone Tumour Service over a two-year period, were reviewed. A correct diagnosis was reached in 97% (133 out of 137) using this technique alone. Needle biopsy is safe and accurate when undertaken in consultation within a bone tumour service; it offers considerable advantages to both patient and surgeon over conventional open biopsy.


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 6 | Pages 959 - 965
1 Nov 1990
Kavanagh T Cannon Pringle J Stoker D Kemp H

We have reviewed 20 cases of parosteal osteosarcoma treated by wide local resection and prosthetic replacement and followed up for six to 17 years. Limb function was excellent in 85%. One patient with grade III histological disease developed pulmonary metastases. Four patients had local recurrences, which were related to repeated preliminary biopsies, inappropriate siting of biopsy and vascular encroachment by the tumour. After this mode of treatment, the outcome was not related to medullary invasion by the tumour.


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 1 | Pages 141 - 142
1 Jan 1989
Pring D Constant O Bayley J Stoker D


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 1 | Pages 147 - 150
1 Jan 1986
Calvert P Packer N Stoker D Bayley J Kessel L

Double-contrast shoulder arthrograms were performed in 20 patients at an average of 30 months after operative repair of a torn rotator cuff. In 18 out of 20 shoulders the contrast medium leaked into the subacromial bursa indicating a defect in the rotator cuff. Despite this, 17 patients had complete relief of pain and 15 had a full range of shoulder elevation. The results suggest that a completely watertight closure is not essential for a good functional result, and that arthrography may not be helpful in the investigation of failure of repair.


The Journal of Bone & Joint Surgery British Volume
Vol. 62-B, Issue 1 | Pages 3 - 6
1 Feb 1980
Ireland J Trickey E Stoker D

A series of 135 knee arthroscopies has been reviewed to determine the accuracy of detection of meniscal lesions. Arthroscopy and double-contrast arthrography achieved similar accuracy (84 per cent and 86 per cent) in the diagnostically more difficult knees of the series. The combined accuracy of both examinations was 98 per cent. Arthroscopic difficulty in seeing the posterior third of the medial meniscus, and consequently tears in this region, is emphasised and discussed. Arthroscopy and arthrography are complementary in the diagnosis of difficult meniscal problems.


The Journal of Bone & Joint Surgery British Volume
Vol. 55-B, Issue 2 | Pages 445 - 446
1 May 1973
Stoker D