The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 1 | Pages 50 - 52
1 Jan 1992
Wilson N Das S Kakkar V Maurice H Smibert J Thomas E Nixon J

We performed a prospective randomised controlled trial of a new mechanical method of prophylaxis for venous thrombo-embolism in 60 patients undergoing knee replacement surgery. The method uses the A-V Impulse System to produce cyclical compression of the venous reservoir of the foot. The overall incidence of deep-vein thrombosis was 68.7% in patients receiving no prophylaxis and 50% in those using the device. The difference was not significant. There was, however, a reduction of the extent of thrombosis in the treated group. There were 13 major calf-vein thrombi and six proximal-vein thrombi in the control group compared with only five major calf-vein thrombi in the treated group. This difference was significant (p = 0.014). No patient developed clinical features of a pulmonary embolism.


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 1 | Pages 92 - 93
1 Jan 1989
Nixon J

Sublaminar wiring provides strong and effective fixation of the scoliotic or unstable spine, but its long-term effects on the spinal canal remain unknown. An animal model was developed to observe these effects on the growth and development of the immature spine over a two-year period. Laminar overgrowth occurred both longitudinally to produce a kyphoscoliosis and in the transverse plane to cause significant laminar thickening and growth into the spinal canal. However, the cross-sectional area of the spinal canal was not significantly compromised.