header advert
Results 1 - 4 of 4
Results per page:
The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 85 - 90
1 Jun 2020
Blevins JL Rao V Chiu Y Lyman S Westrich GH

Aims

The purpose of this investigation was to determine the relationship between height, weight, and sex with implant size in total knee arthroplasty (TKA) using a multivariate linear regression model and a Bayesian model.

Methods

A retrospective review of an institutional registry was performed of primary TKAs performed between January 2005 and December 2016. Patient demographics including patient age, sex, height, weight, and body mass index (BMI) were obtained from registry and medical record review. In total, 8,100 primary TKAs were included. The mean age was 67.3 years (SD 9.5) with a mean BMI of 30.4 kg/m2 (SD 6.3). The TKAs were randomly split into a training cohort (n = 4,022) and a testing cohort (n = 4,078). A multivariate linear regression model was created on the training cohort and then applied to the testing cohort . A Bayesian model was created based on the frequencies of implant sizes in the training cohort. The model was then applied to the testing cohort to determine the accuracy of the model at 1%, 5%, and 10% tolerance of inaccuracy.


The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 48 - 54
1 Jul 2019
Kahlenberg CA Lyman S Joseph AD Chiu Y Padgett DE

Aims

The outcomes of total knee arthroplasty (TKA) depend on many factors. The impact of implant design on patient-reported outcomes is unknown. Our goal was to evaluate the patient-reported outcomes and satisfaction after primary TKA in patients with osteoarthritis undergoing primary TKA using five different brands of posterior-stabilized implant.

Patients and Methods

Using our institutional registry, we identified 4135 patients who underwent TKA using one of the five most common brands of implant. These included Biomet Vanguard (Zimmer Biomet, Warsaw, Indiana) in 211 patients, DePuy/Johnson & Johnson Sigma (DePuy Synthes, Raynham, Massachusetts) in 222, Exactech Optetrak Logic (Exactech, Gainesville, Florida) in 1508, Smith & Nephew Genesis II (Smith & Nephew, London, United Kingdom) in 1415, and Zimmer NexGen (Zimmer Biomet) in 779 patients. Patients were evaluated preoperatively using the Knee Injury and Osteoarthritis Outcome Score (KOOS), Lower Extremity Activity Scale (LEAS), and 12-Item Short-Form Health Survey questionnaire (SF-12). Demographics including age, body mass index, Charlson Comorbidity Index, American Society of Anethesiologists status, sex, and smoking status were collected. Postoperatively, two-year KOOS, LEAS, SF-12, and satisfaction scores were compared between groups.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1209 - 1215
1 Sep 2012
Murakami AM Hash TW Hepinstall MS Lyman S Nestor BJ Potter HG

Component malalignment can be associated with pain following total knee replacement (TKR). Using MRI, we reviewed 50 patients with painful TKRs and compared them with a group of 16 asymptomatic controls to determine the feasibility of using MRI in evaluating the rotational alignment of the components. Using the additional soft-tissue detail provided by this modality, we also evaluated the extent of synovitis within these two groups. Angular measurements were based on the femoral transepicondylar axis and tibial tubercle. Between two observers, there was very high interobserver agreement in the measurements of all values. Patients with painful TKRs demonstrated statistically significant relative internal rotation of the femoral component (p = 0.030). There was relative internal rotation of the tibial to femoral component and combined excessive internal rotation of the components in symptomatic knees, although these results were significant only with one of the observers (p = 0.031). There was a statistically significant association between the presence and severity of synovitis and painful TKR (p < 0.001).

MRI is an effective modality in evaluating component rotational alignment.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 1 | Pages 47 - 51
1 Jan 2011
Hetsroni I Lyman S Do H Mann G Marx RG

Pulmonary embolism is a serious complication after arthroscopy of the knee, about which there is limited information. We have identified the incidence and risk factors for symptomatic pulmonary embolism after arthroscopic procedures on outpatients. The New York State Department of Health Statewide Planning and Research Cooperative System database was used to review arthroscopic procedures of the knee performed on outpatients between 1997 and 2006, and identify those admitted within 90 days of surgery with an associated diagnosis of pulmonary embolism. Potential risk factors included age, gender, complexity of surgery, operating time defined as the total time that the patient was actually in the operating room, history of cancer, comorbidities, and the type of anaesthesia. We identified 374 033 patients who underwent 418 323 outpatient arthroscopies of the knee. There were 117 events of pulmonary embolism (2.8 cases for every 10 000 arthroscopies). Logistic regression analysis showed that age and operating time had significant dose-response increases in risk (p < 0.001) for a subsequent admission with a pulmonary embolism. Female gender was associated with a 1.5-fold increase in risk (p = 0.03), and a history of cancer with a threefold increase (p = 0.05).

These risk factors can be used when obtaining informed consent before surgery, to elevate the level of clinical suspicion of pulmonary embolism in patients at risk, and to establish a rationale for prospective studies to test the clinical benefit of thromboprophylaxis in high-risk patients.