The Bone & Joint Journal
Vol. 98-B, Issue 2 | Pages 166 - 172
1 Feb 2016
Langlois J Hamadouche M

Previous standards for assessing the reliability of a measurement tool have lacked consistency. We reviewed the most current American Society for Testing and Materials and International Organisation for Standardisation (ISO) recommendations, and propose an algorithm for orthopaedic surgeons. When assessing a measurement tool, conditions of the experimental set-up and clear formulae used to compile the results should be strictly reported. According to these recent guidelines, accuracy is a confusing word with an overly broad meaning and should therefore be abandoned. Depending on the experimental conditions, one should be referring to bias (when the study protocol involves accepted reference values), and repeatability (sr, r) or reproducibility (SR, R). In the absence of accepted reference values, only repeatability (sr, r) or reproducibility (SR, R) should be provided.

Take home message: Assessing the reliability of a measurement tool involves reporting bias, repeatability and/or reproducibility depending on the defined conditions, instead of precision or accuracy.

Cite this article: Bone Joint J 2016;98-B2:166–72.


The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1458 - 1462
1 Nov 2015
Langlois J Atlan F Scemama C Courpied JP Hamadouche M

Most published randomised controlled trials which compare the rates of wear of conventional and cross-linked (XL) polyethylene (PE) in total hip arthroplasty (THA) have described their use with a cementless acetabular component.

We conducted a prospective randomised study to assess the rates of penetration of two distinct types of PE in otherwise identical cemented all-PE acetabular components.

A total of 100 consecutive patients for THA were randomised to receive an acetabular component which had been either highly XL then remelted or moderately XL then annealed.

After a minimum of eight years follow-up, 38 hips in the XL group and 30 hips in the annealed group had complete data (mean follow-up of 9.1 years (7.6 to 10.7) and 8.7 years (7.2 to 10.2), respectively). In the XL group, the steady state rate of penetration from one year onwards was -0.0002 mm/year (sd 0.108): in the annealed group it was 0.1382 mm/year (sd 0.129) (Mann–Whitney U test, p < 0.001). No complication specific to either material was recorded.

These results show that the yearly linear rate of femoral head penetration can be significantly reduced by using a highly XLPE cemented acetabular component.

Cite this article: Bone Joint J 2015;97-B:1458–62.