header advert
Results 1 - 1 of 1
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 4 | Pages 557 - 560
1 Aug 1986
Esser M Kassab J Jones D

In a randomised prospective trial 98 elderly women with trochanteric fractures of the femur were treated with either a 135 degrees Jewett nail-plate or a 135 degrees Dynamic hip screw. The results at six weeks, three months and six months were statistically analysed. There were no significant differences in the two groups with regard to pain, length of hospital stay, morbidity or mortality. Although operative difficulties and open reduction were more common with the Dynamic hip screw, at the end of six months more patients in this group were mobile and there was significant radiological evidence of better compression without loss of fixation.