A silver-containing hydroxyapatite (Ag-HA) coating has been developed using thermal spraying technology. We evaluated the osteoconductivity of this coating on titanium (Ti) implants in rat tibiae in relation to bacterial infection in joint replacement. At 12 weeks, the mean affinity indices of bone formation of a Ti, an HA, a 3%Ag-HA and a 50%Ag-HA coating were 97.3%, 84.9%, 81.0% and 40.5%, respectively. The mean affinity indices of bone contact of these four coatings were 18.8%, 83.7%, 77.2% and 40.5%, respectively. The indices of bone formation and bone contact around the implant of the 3%Ag-HA coating were similar to those of the HA coating, and no significant differences were found between them (bone formation, p = 0.99; bone contact, p = 0.957). However, inhibition of bone formation was observed with the 50%Ag-HA coating. These results indicate that the 3%Ag-HA coating has low toxicity and good osteoconductivity, and that the effect of silver toxicity on osteoconductivity depends on the dose.
Six major and seven minor diagnostic criteria have been developed by the Japanese Investigation Committee for osteonecrosis of the femoral head (ONFH). We have carried out a multicentre study to clarify these. We studied prospectively 277 hips in 222 patients, from six hospitals, who had ONFH and other hip pathology and from whom histological material was available. We identified five criteria with high specificity: 1) collapse of the femoral head without narrowing of the joint space or acetabular abnormality on radiographs, including the crescent sign; 2) demarcating sclerosis in the femoral head without narrowing or acetabular abnormality; 3) a ‘cold-in-hot’ appearance on the bone scan; 4) a low-intensity band on T1-weighted images (band pattern); and 5) evidence of trabecular and marrow necrosis on histological examination. With any combination of two of these criteria, the sensitivity and specificity of the diagnosis were 91% and 99%, respectively.