Advertisement for orthosearch.org.uk
Results 1 - 4 of 4
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 4 | Pages 545 - 550
1 Aug 1987
Roberts J Finlayson D Freeman P

We present the results of 506 consecutive Howse hip arthroplasties with a minimum follow-up of 10 years. The mortality within one month of surgery was 0.79%. The early dislocation rate was 1.38%, two hips requiring revision. Nine hips developed deep sepsis (1.78%), eight of which required revision. At 10 years 42 hips (8.3%) had required revision, including 14 with aseptic acetabular loosening and 11 with femoral stem fractures. We feel that as judged by the dislocation rate and the need for subsequent revision, the Howse arthroplasty is an acceptable form of total hip replacement, particularly in the older patient and in those requiring total replacement for femoral neck fractures.


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 1 | Pages 8 - 12
1 Jan 1987
Zoma A Sturrock R Fisher W Freeman P Hamblen D

We have reviewed 32 patients with rheumatoid disease of the cervical spine who underwent a total of 40 operations aimed at correcting instability and improving any associated neurovascular deficit. Apart from four patients with intractable pain, the main indication for surgery was progressive neurological impairment. Of the 32 primary operations, 19 (60%) were successful; the remainder failed to achieve their objective and there were two deaths in the immediate postoperative period. Of eight secondary operations performed for recurrence of symptoms or failure to relieve cervical myelopathy, only four were successful. Of nine operations for bony decompression to relieve cord compression from irreducible subluxation, only four were successful. The overall results show a success rate of 57% and a failure rate of 35% with early operative mortality in 8%. Indications for operation are discussed and earlier diagnosis is considered to be the key to improved results.


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 2 | Pages 163 - 165
1 Mar 1983
Small M Steven M Freeman P Lowe G Belch J Forbes C Prentice C

The results of total knee replacement in five patients aged between 22 and 37 with severe haemophilia A or B are described. All patients had been managed conservatively without success. Frequent bleeds, severe pain and limitation of movement were the indications for operation. Despite close haematological surveillance, bleeding problems occurred in three of the patients and large quantities of plasma concentrates were required. Review of the patients over a period of 25 to 48 months after operation showed dramatic lessening of pain and maintenance of a satisfactory range of movement. The frequency of haemarthrosis diminished markedly and the requirements for factor concentrate in the years after operation fell substantially. Two patients returned to employment. Total knee replacement led to marked clinical improvement in all the patients, but the long-term results are not yet known.


The Journal of Bone & Joint Surgery British Volume
Vol. 52-B, Issue 1 | Pages 70 - 76
1 Feb 1970
Dick WC Shenkin A Freeman P Nuki G Whaley K Buchanan WW

1. 133Xe clearance rates as a measure of blood flow were determined in the knees oftwo groups of patients.

2. In the first group eight patients with rheumatoid arthritis were studied before, three months after and one year after synovectomy. Blood flow values were significantly lower three months after operation but the values recorded one year after operation did not differ significantly from those before operation.

3. In the second group (twenty-one patients with rheumatoid arthritis) blood flow values were determined two to three years after synovectomy. The values obtained differed from those obtained in normal joints and fell within the range of values obtained in forty-three patients with rheumatoid arthritis who did not have synovectomy.