To assess the impact of the declaration of the state of emergency due to the COVID-19 pandemic on the number of visits to a traumatology emergency department (ED), and on their severity. Retrospective observational study. All visits to a traumatology ED were recorded, except for consultations for genitourinary, ocular and abdominal trauma and other ailments that did not have a musculoskeletal aetiology. Visit data were collected from March 14 to April 13 2020, and were subsequently compared with the visits recorded during the same periods in the previous two years.Aims
Methods
Failure of fixation is a major complication of the treatment of unstable intertrochanteric fractures. A retrospective review was performed of 54 such fractures treated with a sliding screw-plate device. Linear and angular displacements were calculated from radiographs taken at operation and serially until healing was complete. Linear displacement was related to fracture instability, but the neck-shaft angle was relatively constant during healing. Complications were often due to failure of the sliding mechanism of the implant. We conclude that a sliding screw-plate allows controlled collapse of the major fragments but maintains the neck-shaft angle even in unstable fractures.