Phillips JE Crane TP Noy M Elliott TSJ Grimer RJ

The Control of Infection Committee at a specialist orthopaedic hospital prospectively collected data on all episodes of bacteriologically-proven deep infection arising after primary hip and knee replacements over a 15-year period from 1987 to 2001.

There were 10 735 patients who underwent primary hip or knee replacement. In 34 of 5947 hip replacements (0.57%) and 41 of 4788 knee replacements (0.86%) a deep infection developed. The most common infecting micro-organism was coagulase-negative staphylococcus, followed by Staphylococcus aureus, enterococci and streptococci. Of the infecting organisms, 72% were sensitive to routine prophylactic antimicrobial agents.

Of the infections, 29% (22) arose in the first three months following surgery, 35% between three months and one year (26), and 36% (27) after one year. Most cases were detected early and treated aggressively, with eradication of the infection in 96% (72). There was no significant change in the infection rate or type of infecting micro-organism over the course of this study.

These results set a benchmark, and importantly emphasise that only 64% of peri-prosthetic infections arise within one year of surgery. These results also illustrate the advantages of conducting joint replacement surgery in the isolation of a specialist hospital.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 8 | Pages 1156 - 1161
1 Nov 2000
Rafiq M Worthington T Tebbs SE Treacy RBC Dias R Lambert PA Elliott TSJ

Coagulase-negative staphylococci produce an exocellular glycolipid antigen which has potential as a serological marker of infection in bone. The value of this newly detected antigen was investigated by enzyme-linked immunosorbent assay (ELISA) in 15 patients with culture-proven infection of prostheses caused by Gram-positive bacteria. The antigen was purified by gel-permeation chromatography from the culture supernatants of coagulase-negative staphylococci grown in a chemically defined medium.

There were significant differences (p < 0.0001) between the serum IgG and IgM levels in patients with infection due to Gram-positive staphylococci and those of a control group of 32 patients with no infection. The ELISA test, which has potential for the diagnosis of infection, may be valuable in distinguishing between staphylococcal infection around prostheses and aseptic loosening.