Advertisement for orthosearch.org.uk
Results 1 - 20 of 124
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 8 | Pages 1045 - 1048
1 Aug 2008
Shetty AA Tindall AJ James KD Relwani J Fernando KW

The diagnosis of a meniscal tear may require MRI, which is costly. Ultrasonography has been used to image the meniscus, but there are no reliable data on its accuracy. We performed a prospective study investigating the sensitivity and specificity of ultrasonography in comparison with MRI; the final outcome was determined at arthroscopy. The study included 35 patients with a mean age of 47 years (14 to 73).

There was a sensitivity of 86.4% (95% confidence interval (CI) 75 to 97.7), a specificity of 69.2% (95% CI 53.7 to 84.7), a positive predictive value of 82.6% (95% CI 70 to 95.2) and a negative predictive value of 75% (95% CI 60.7 to 81.1) for ultrasonography. This compared favourably with a sensitivity of 86.4% (95% CI 75 to 97.7), a specificity of 100.0%, a positive predictive value of 100.0% and a negative predictive value of 81.3% (95% CI 74.7 to 87.9) for MRI.

Given that the sensitivity matched that of MRI we feel that ultrasonography can reasonably be applied to confirm the clinical diagnosis before undertaking arthroscopy. However, the lower specificity suggests that there is still a need to improve the technique to reduce the number of false-positive diagnoses and thus to avoid unnecessary arthroscopy.


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 487 - 495
1 May 2023
Boktor J Wong F Joseph VM Alshahwani A Banerjee P Morris K Lewis PM Ahuja S

Aims. The early diagnosis of cauda equina syndrome (CES) is crucial for a favourable outcome. Several studies have reported the use of an ultrasound scan of the bladder as an adjunct to assess the minimum post-void residual volume of urine (mPVR). However, variable mPVR values have been proposed as a threshold without consensus on a value for predicting CES among patients with relevant symptoms and signs. The aim of this study was to perform a meta-analysis and systematic review of the published evidence to identify a threshold mPVR value which would provide the highest diagnostic accuracy in patients in whom the diagnosis of CES is suspected. Methods. The search strategy used electronic databases (PubMed, Medline, EMBASE, and AMED) for publications between January 1996 and November 2021. All studies that reported mPVR in patients in whom the diagnosis of CES was suspected, followed by MRI, were included. Results. A total of 2,115 studies were retrieved from the search. Seven fulfilled the inclusion criteria. These included 1,083 patients, with data available from 734 being available for meta-analysis. In 125 patients, CES was confirmed by MRI. The threshold value of mPVR reported in each study varied and could be categorized into 100 ml, 200 ml, 300 ml, and 500 ml. From the meta-analysis, 200 ml had the highest diagnostic accuracy, with 82% sensitivity (95% confidence interval (CI) 0.72 to 0.90) and 65% specificity (95% CI 0.70 to 0.90). When compared using summative receiver operating characteristic curves, mPVR of 200 ml was superior to other values in predicting the radiological confirmation of CES. Conclusion. mPVR is a useful tool when assessing patients in whom the diagnosis of CES is suspected. Compared with other values a mPVR of 200 ml had superior sensitivity, specificity, and positive and negative predictive values. In a patient with a suggestive history and clinical findings, a mPVR of > 200 ml should further raise the suspicion of CES. Caution is recommended when considering the mPVR in isolation and using it as an ‘exclusion tool’, and it should only be used as an adjunct to a full clinical assessment. Cite this article: Bone Joint J 2023;105-B(5):487–495


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 227 - 231
1 Mar 2024
Todd NV Casey A Birch NC

The diagnostic sub-categorization of cauda equina syndrome (CES) is used to aid communication between doctors and other healthcare professionals. It is also used to determine the need for, and urgency of, MRI and surgery in these patients. A recent paper by Hoeritzauer et al (2023) in this journal examined the interobserver reliability of the widely accepted subcategories in 100 patients with cauda equina syndrome. They found that there is no useful interobserver agreement for the subcategories, even for experienced spinal surgeons. This observation is supported by the largest prospective study of the treatment of cauda equina syndrome in the UK by Woodfield et al (2023). If the accepted subcategories are unreliable, they cannot be used in the way that they are currently, and they should be revised or abandoned. This paper presents a reassessment of the diagnostic and prognostic subcategories of cauda equina syndrome in the light of this evidence, with a suggested cure based on a more inclusive synthesis of symptoms, signs, bladder ultrasound scan results, and pre-intervention urinary catheterization. Cite this article: Bone Joint J 2024;106-B(3):227–231


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 209 - 214
1 Feb 2023
Aarvold A Perry DC Mavrotas J Theologis T Katchburian M

Aims. A national screening programme has existed in the UK for the diagnosis of developmental dysplasia of the hip (DDH) since 1969. However, every aspect of screening and treatment remains controversial. Screening programmes throughout the world vary enormously, and in the UK there is significant variation in screening practice and treatment pathways. We report the results of an attempt by the British Society for Children’s Orthopaedic Surgery (BSCOS) to identify a nationwide consensus for the management of DDH in order to unify treatment and suggest an approach for screening. Methods. A Delphi consensus study was performed among the membership of BSCOS. Statements were generated by a steering group regarding aspects of the management of DDH in children aged under three months, namely screening and surveillance (15 questions), the technique of ultrasound scanning (eight questions), the initiation of treatment (19 questions), care during treatment with a splint (ten questions), and on quality, governance, and research (eight questions). A two-round Delphi process was used and a consensus document was produced at the final meeting of the steering group. Results. A total of 60 statements were graded by 128 clinicians in the first round and 132 in the second round. Consensus was reached on 30 out of 60 statements in the first round and an additional 12 in the seond. This was summarized in a consensus statement and distilled into a flowchart to guide clinical practice. Conclusion. We identified agreement in an area of medicine that has a long history of controversy and varied practice. None of the areas of consensus are based on high-quality evidence. This document is thus a framework to guide clinical practice and on which high-quality clinical trials can be developed. Cite this article: Bone Joint J 2023;105-B(2):209–214


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1123 - 1130
1 Oct 2023
Donnan M Anderson N Hoq M Donnan L

Aims. The aim of this study was to investigate the agreement in interpretation of the quality of the paediatric hip ultrasound examination, the reliability of geometric and morphological assessment, and the relationship between these measurements. Methods. Four investigators evaluated 60 hip ultrasounds and assessed their quality based the standard plane of Graf et al. They measured geometric parameters, described the morphology of the hip, and assigned the Graf grade of dysplasia. They analyzed one self-selected image and one randomly selected image from the ultrasound series, and repeated the process four weeks later. The intra- and interobserver agreement, and correlations between various parameters were analyzed. Results. In the assessment of quality, there a was moderate to substantial intraobserver agreement for each element investigated, but interobserver agreement was poor. Morphological features showed weak to moderate agreement across all parameters but improved to significant when responses were reduced. The geometric measurements showed nearly perfect agreement, and the relationship between them and the morphological features showed a dose response across all parameters with moderate to substantial correlations. There were strong correlations between geometric measurements. The Graf classification showed a fair to moderate interobserver agreement, and moderate to substantial intraobserver agreement. Conclusion. This investigation into the reliability of the interpretation of hip ultrasound scans identified the difficulties in defining what is a high-quality ultrasound. We confirmed that geometric measurements are reliably interpreted and may be useful as a further measurement of quality. Morphological features are generally poorly interpreted, but a simpler binary classification considerably improves agreement. As there is a clear dose response relationship between geometric and morphological measurements, the importance of morphology in the diagnosis of hip dysplasia should be questioned. Cite this article: Bone Joint J 2023;105-B(10):1123–1130


The Bone & Joint Journal
Vol. 101-B, Issue 6 | Pages 635 - 638
1 Jun 2019
Marson BA Hunter JB Price KR

Aims. The aim of this study was to review the value of accepting referrals for children with ‘clicky hips’ in a selective screening programme for hip dysplasia. Patients and Methods. A single-centre prospective database of all referrals to the hip clinic was examined to identify indication for referrals, diagnosis, and treatment. All patients referred received a standardized ultrasound scan and clinical examination by an orthopaedic consultant. Results. There were 5716 children referred to the orthopaedic hip clinic between 1 June 2014 and 26 September 2018. In all, 1754 children (30.1%) were referred due to ‘clicky hip’ with no additional risk factors or indications for ultrasound scan. A total of 123 children (7.1%) referred with ‘clicky hip’ and no additional risk factors or examination findings had an abnormal initial hip ultrasound, including 16 children (0.9%) with dysplastic hips. Of the 141 children who required treatment in a Pavlik harness during the study period, 23 (16%) had been referred with a ‘clicky hip’ and no additional risk factors or examination findings, including six children with Graf 3 or 4 hips. Conclusion. There is significant value in reviewing children with an isolated ‘clicky hip’. Many children who require treatment are referred to the orthopaedic service as ‘clicky hip’ with no additional risk factors. In a pragmatic pathway with a diverse population of clinicians performing baby checks, ‘clicky hip’ is an important indication for referral and should not be discarded. Cite this article: Bone Joint J 2019;101-B:635–638


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 495 - 500
1 Apr 2020
Milligan DJ Cosgrove AP

Aims. To monitor the performance of services for developmental dysplasia of the hip (DDH) in Northern Ireland and identify potential improvements to enhance quality of service and plan for the future. Methods. This was a prospective observational study, involving all infants treated for DDH between 2011 and 2017. Children underwent clinical assessment and radiological investigation as per the regional surveillance policy. The regional radiology data was interrogated to quantify the use of ultrasound and ionizing radiation for this population. Results. Evidence-based changes were made to the Northern Ireland screening programme, including an increase in ultrasound scanning capacity and expansion of nurse-led screening clinics. The number of infant hip ultrasound scans increased from 4,788 in 2011, to approximately 7,000 in 2013 and subsequent years. The number of hip radiographs on infants of less than one year of age fell from 7,381 to 2,208 per year. There was a modest increase in the treatment rate from 10.9 to 14.3 per 1,000 live births but there was a significant reduction in the number of closed hip reductions. The incidence of infants diagnosed with DDH after one year of age was 0.30 per 1,000 live births over the entire period. Conclusion. Improving compliance with the regional infant hip screening protocols led to reduction in operative procedures and reduced the number of pelvic radiographs of infants. We conclude that performance monitoring of screening programmes for DDH is essential to provide a quality service. Cite this article: Bone Joint J 2020;102-B(4):495–500


Bone & Joint Research
Vol. 10, Issue 12 | Pages 759 - 766
1 Dec 2021
Nicholson JA Oliver WM MacGillivray TJ Robinson CM Simpson AHRW

Aims. The aim of this study was to establish a reliable method for producing 3D reconstruction of sonographic callus. Methods. A cohort of ten closed tibial shaft fractures managed with intramedullary nailing underwent ultrasound scanning at two, six, and 12 weeks post-surgery. Ultrasound capture was performed using infrared tracking technology to map each image to a 3D lattice. Using echo intensity, semi-automated mapping was performed to produce an anatomical 3D representation of the fracture site. Two reviewers independently performed 3D reconstructions and kappa coefficient was used to determine agreement. A further validation study was undertaken with ten reviewers to estimate the clinical application of this imaging technique using the intraclass correlation coefficient (ICC). Results. Nine of the ten patients achieved union at six months. At six weeks, seven patients had bridging callus of ≥ one cortex on the 3D reconstruction and when present all achieved union. Compared to six-week radiographs, no bridging callus was present in any patient. Of the three patients lacking sonographic bridging callus, one went onto a nonunion (77.8% sensitive and 100% specific to predict union). At 12 weeks, nine patients had bridging callus at ≥ one cortex on 3D reconstruction (100%-sensitive and 100%-specific to predict union). Presence of sonographic bridging callus on 3D reconstruction demonstrated excellent reviewer agreement on ICC at 0.87 (95% confidence interval 0.74 to 0.96). Conclusion. 3D fracture reconstruction can be created using multiple ultrasound images in order to evaluate the presence of bridging callus. This imaging modality has the potential to enhance the usability and accuracy of identification of early fracture healing. Cite this article: Bone Joint Res 2021;10(12):759–766


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 889 - 892
1 Jul 2008
Al-Shawi A Badge R Bunker T

We have examined the accuracy of 143 consecutive ultrasound scans of patients who subsequently underwent shoulder arthroscopy for rotator-cuff disease. All the scans and subsequent surgery were performed by an orthopaedic surgeon using a portable ultrasound scanner in a one-stop clinic. There were 78 full thickness tears which we confirmed by surgery or MRI. Three moderate-size tears were assessed as partial-thickness at ultrasound scan (false negative) giving a sensitivity of 96.2%. One partially torn and two intact cuffs were over-diagnosed as small full-thickness tears by ultrasound scan (false positive) giving a specificity of 95.4%. This gave a positive predictive value of 96.2% and a negative predictive value of 95.4%. Estimation of tear size was more accurate for large and massive tears at 96.5% than for moderate (88.8%) and small tears (91.6%). These results are equivalent to those obtained by several studies undertaken by experienced radiologists. We conclude that ultrasound imaging of the shoulder performed by a sufficiently-trained orthopaedic surgeon is a reliable time-saving practice to identify rotator-cuff integrity


The Bone & Joint Journal
Vol. 100-B, Issue 9 | Pages 1249 - 1252
1 Sep 2018
Humphry S Thompson D Price N Williams PR

Aims. The significance of the ‘clicky hip’ in neonatal and infant examination remains controversial with recent conflicting papers reigniting the debate. We aimed to quantify rates of developmental dysplasia of the hip (DDH) in babies referred with ‘clicky hips’ to our dedicated DDH clinic. Patients and Methods. A three-year prospective cohort study was undertaken between 2014 and 2016 assessing the diagnosis and treatment outcomes of all children referred specifically with ‘clicky hips’ as the primary reason for referral to our dedicated DDH clinic. Depending on their age, they were all imaged with either ultrasound scan or radiographs. Results. There were 69 ‘clicky hip’ referrals over the three-year period. This represented 26.9% of the total 257 referrals received in that time. The mean age at presentation was 13.6 weeks (1 to 84). A total of 19 children (28%) referred as ‘clicky hips’ were noted to have hip abnormalities on ultrasound scan, including 15 with Graf Type II hips (7 bilateral), one Graf Type III hip, and three Graf Type IV hips. Of these, ten children were treated with a Pavlik harness, with two requiring subsequent closed reduction in theatre; one child was treated primarily with a closed reduction and adductor tenotomy. In total, 11 (15.9%) of the 69 ‘clicky hip’ referrals required intervention with either harness or surgery. Conclusion. Our study provides further evidence that the ‘clicky hip’ referral can represent an underlying diagnosis of DDH and should, in our opinion, always lead to further clinical and radiological assessment. In the absence of universal ultrasound screening, we would encourage individual units to carefully assess their own outcomes and protocols for ‘clicky hip’ referrals and tailor ongoing service provision to local populations and local referral practices. Cite this article: Bone Joint J 2018;100-B:1249–52


The Bone & Joint Journal
Vol. 102-B, Issue 11 | Pages 1535 - 1541
1 Nov 2020
Yassin M Myatt R Thomas W Gupta V Hoque T Mahadevan D

Aims. Functional rehabilitation has become an increasingly popular treatment for Achilles tendon rupture (ATR), providing comparably low re-rupture rates to surgery, while avoiding risks of surgical complications. Limited evidence exists on whether gap size should affect patient selection for this treatment option. The aim of this study was to assess if size of gap between ruptured tendon ends affects patient-reported outcome following ATR treated with functional rehabilitation. Methods. Analysis of prospectively collected data on all 131 patients diagnosed with ATR at Royal Berkshire Hospital, UK, from August 2016 to January 2019 and managed non-operatively was performed. Diagnosis was confirmed on all patients by dynamic ultrasound scanning and gap size measured with ankle in full plantarflexion. Functional rehabilitation using an established protocol was the preferred treatment. All non-operatively treated patients with completed Achilles Tendon Rupture Scores (ATRS) at a minimum of 12 months following injury were included. Results. In all, 82 patients with completed ATRS were included in the analysis. Their mean age was 51 years (standard deviation (SD) 14). The mean ATRS was 76 (SD 19) at a mean follow-up of 20 months (SD 11) following injury. Gap inversely affected ATRS with a Pearson’s correlation of -0.30 (p = 0.008). Mean ATRS was lower with gaps > 5 mm compared with ≤ 5 mm (73 (SD 21) vs 82 (SD 16); p = 0.031). Mean ATRS was lowest (70 (SD 23)) with gaps > 10 mm, with significant differences in perceived strength and pain. The overall re-rupture rate was two out of 131 (1.5%). Conclusion. Increasing gap size predicts lower patient-reported outcome, as measured by ATRS. Tendon gap > 5 mm may be a useful predictor in physically demanding individuals, and tendon gap > 10 mm for those with low physical demand. Further studies that control for gap size when comparing non-operative and operative treatment are required to assess if these patients may benefit from surgery, particularly when balanced against the surgical risks. Cite this article: Bone Joint J 2020;102-B(11):1535–1541


The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 677 - 682
1 Jun 2020
Katzouraki G Zubairi AJ Hershkovich O Grevitt MP

Aims. Diagnosis of cauda equina syndrome (CES) remains difficult; clinical assessment has low accuracy in reliably predicting MRI compression of the cauda equina (CE). This prospective study tests the usefulness of ultrasound bladder scans as an adjunct for diagnosing CES. Methods. A total of 260 patients with suspected CES were referred to a tertiary spinal unit over a 16-month period. All were assessed by Board-eligible spinal surgeons and had transabdominal ultrasound bladder scans for pre- and post-voiding residual (PVR) volume measurements before lumbosacral MRI. Results. The study confirms the low predictive value of ‘red flag’ symptoms and signs. Of note ‘bilateral sciatica’ had a sensitivity of 32.4%, and a positive predictive value (PPV) of only 17.2%, and negative predictive value (NPV) 88.3%. Use of a PVR volume of ≥ 200 ml was a demonstrably more accurate test for predicting cauda equina compression on subsequent MRI (p < 0.001). The PVR sensitivity was 94.1%, specificity 66.8%, PPV 29.9% and NPV 98.7%. The PVR allowed risk-stratification with 13% patients deemed ‘low-risk’ of CES. They had non-urgent MRI scans. None of the latter scans showed any cauda equina compression (p < 0.006) or individuals developed subsequent CES in the intervening period. There were considerable cost-savings associated with the above strategy. Conclusion. This is the largest reported prospective evaluation of suspected CES. Use of the PVR volume ≥ 200 ml was considerably more accurate in predicting CES. It is a useful adjunct to conventional clinical assessment and allows risk-stratification in managing suspected CES. If adopted widely it is less likely incomplete CES would be missed. Cite this article: Bone Joint J 2020;102-B(6):677–682


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 6 | Pages 876 - 880
1 Aug 2000
Tillett RL Fisk NM Murphy K Hunt DM

Congenital talipes equinovarus is a common anomaly which can now be diagnosed prenatally on a routine ultrasound scan at 20 weeks of gestation. Prenatal counselling is increasingly offered to parents with affected fetuses, but it is difficult to counsel parents if there is a chance that the fetus may not have talipes. Our study correlates the prenatal ultrasound findings of 14 infants diagnosed as having unilateral or bilateral talipes during their routine 20-week ultrasound scan with their clinical findings at birth and the treatment received. No feet diagnosed as talipes on the ultrasound scan were completely normal at birth and therefore there were no true false-positive results. One foot graded as normal at 20 weeks was found to have a mild grade-1 talipes at birth, but did not require treatment other than simple stretches. A total of 32% of feet required no treatment and so could be considered functional false-positive results on the scan. Serial casting was required by 13% of feet and surgical treatment by 55%. The severity of the talipes is difficult to establish before birth. A number of patients are likely to need surgical treatment, but a proportion will have talipes so mildly that no treatment will be required. In counselling parents at 20 weeks, orthopaedic surgeons need to know whether or not there is a small chance that the ultrasound diagnosis could be wrong and also that the talipes may be so mild that the foot will not require treatment


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1449 - 1451
1 Oct 2010
Jaiswal A Starks I Kiely NT

We present a case of late dislocation of the hip in a 30-month-old girl. Her hip was clinically stable at birth and an ultrasound scan at six weeks was normal. She had no additional risk factors for developmental dysplasia. She underwent anterior open reduction with a femoral osteotomy


The Bone & Joint Journal
Vol. 95-B, Issue 1 | Pages 132 - 134
1 Jan 2013
Barr LV Rehm A

Twins are often considered to be at an increased risk of developmental dysplasia of the hip (DDH); we therefore investigated whether multiple births have a higher incidence of DDH, and if selective ultrasound scanning should be considered for these infants. We reviewed our records of all live births between 1 January 2004 and 31 December 2008 and included 25 246 single and 990 multiple births. Multiple births did not have a significantly higher incidence of DDH compared with single births (0.0030 vs 0.0023, p = 0.8939). Of the 990 multiple births, 267 had neonatal ultrasound scans and one case of DDH was diagnosed and treated successfully with a Pavlik harness. There were two late-presenting cases at eight and 14 months of age, neither of whom had risk factors for DDH and consequently had not had a neonatal scan. Whereas selective ultrasound scanning of multiple births would have led to earlier detection and treatment of the late-presenting cases, they did not have a significantly higher incidence of DDH compared with single births. We conclude that being a twin or triplet in itself is not a risk factor for DDH and that selective ultrasound scanning is not indicated for this population. Cite this article: Bone Joint J 2013;95-B:132–4


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 7 | Pages 1013 - 1016
1 Jul 2010
Walton MJ Isaacson Z McMillan D Hawkes R Atherton WG

We present the results of treatment of developmental dysplasia of the hip in infancy with the Pavlik harness using a United Kingdom screening programme with ultrasound-guided supervision. Initially, 128 consecutive hips in 77 patients were reviewed over a 40-month period; 123 of these were finally included in the study. The mean age of the patients at the start of treatment was five weeks (1 to 12). All hips were examined clinically and monitored with ultrasound scanning. Failure of treatment was defined as an inability to maintain reduction with the harness. All hips diagnosed with dysplasia or subluxation but not dislocation were managed successfully in the harness. There were 43 dislocated hips, of which 39 were reducible, but six failed treatment in the harness. There were four dislocated but irreducible hips which all failed treatment in the harness. One hip appeared to be successfully treated in the harness but showed persistent radiological dysplasia at 12 and 24 months. Grade 1 avascular necrosis was identified radiologically in three patients at 12 months


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 1 | Pages 130 - 132
1 Jan 1992
Maffulli N Hughes T Fixsen J

Limb lengthening in nine patients was monitored by radiographs and by ultrasound scans. The distraction gap appeared as a sonolucent area within which echogenic foci developed soon after distraction commenced. By seven weeks a new cortex was detected, and medullary canal began to develop between seven and eight weeks. Ultrasound scanning can be used to measure distraction, but it was not as useful as radiographs in detecting angulation. Its use in patients undergoing limb lengthening could reduce their exposure to radiation


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 7 | Pages 990 - 993
1 Jul 2005
Bar-On E Mashiach R Inbar O Weigl D Katz K Meizner I

Club foot was diagnosed by ultrasonography in 91 feet (52 fetuses) at a mean gestational age of 22.1 weeks (14 to 35.6). Outcome was obtained by chart review in 26 women or telephone interview in 26. Feet were classified as normal, positional deformity, isolated club foot or complex club foot. At initial diagnosis, 69 feet (40 fetuses) were classified as isolated club foot and 22 feet (12 fetuses) as complex club foot. The diagnosis was changed after follow-up ultrasound scan in 13 fetuses (25%), and the final ultrasound diagnosis was normal in one fetus, isolated club foot in 31 fetuses, and complex club foot in 20 fetuses. At birth, club foot was found in 79 feet in 43 infants for a positive predictive value of 83%. Accuracy of the specific diagnosis of isolated club foot or complex club foot was lower; 63% at the initial ultrasound scan and 73% at the final scan. The difference in diagnostic accuracy between isolated and complex club foot was not statistically significant. In no case was postnatal complex club foot undiagnosed on fetal ultrasound and all inaccuracies were overdiagnoses. Karyotyping was performed in 25 cases. Abnormalities were noted in three fetuses, all with complex club foot and with additional findings on ultrasound


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1534 - 1539
1 Nov 2012
Karataglis D Papadopoulos P Boutsiadis A Fotiadou A Ditsios K Hatzokos I Christodoulou A

This study evaluates the position of the long head of biceps tendon using ultrasound following simple tenotomy, in patients with arthroscopically repaired rotator cuff tears. In total, 52 patients with a mean age of 60.7 years (45 to 75) underwent arthroscopic repair of the rotator cuff and simple tenotomy of the long head of biceps tendon. At two years post-operatively, ultrasound revealed that the tendon was inside the bicipital groove in 43 patients (82.7%) and outside in nine (17.3%); in six of these it was lying just outside the groove and in the remaining three (5.8%) it was in a remote position with a positive Popeye Sign. A dynamic ultrasound scan revealed that the tenotomised tendons had adhered to the surrounding tissues (autotenodesis).The initial condition of the tendon influenced its final position (p < 0.0005). The presence of a Popeye sign was statistically influenced by the pre-operative co-existence of supraspinatus and subscapularis tears (p < 0.0001). It appears that the natural history of the tenotomised long head of biceps tendon is to tenodese itself inside or just outside the bicipital groove, while its pre-operative condition and coexistent subscapularis tears play a significant role in the occurrence of a Popeye sign


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 10 | Pages 1340 - 1343
1 Oct 2007
Patil S Gandhi J Curzon I Hui ACW

Stable fractures of the ankle can be successfully treated non-operatively by a below-knee plaster cast. In some centres, patients with this injury are routinely administered low-molecular-weight heparin, to reduce the risk of deep-vein thrombosis (DVT). We have assessed the incidence of DVT in 100 patients in the absence of any thromboprophylaxis. A colour Doppler duplex ultrasound scan was done at the time of the removal of the cast. Five patients did develop DVT, though none had clinical signs suggestive of it. One case involved the femoral and another the popliteal vein. No patient developed pulmonary embolism. As the incidence of DVT after ankle fractures is low, we do not recommend routine thromboprophylaxis