header advert
Results 1 - 20 of 403
Results per page:
The Bone & Joint Journal
Vol. 98-B, Issue 4 | Pages 483 - 489
1 Apr 2016
Tigchelaar S Rooy JD Hannink G Koëter S van Kampen A Bongers E

Aim. Nail patella syndrome (NPS) is a skeletal dysplasia with patellofemoral dysfunction as a key symptom. We present the first in-depth radiological evaluation of the knee in a large series of NPS patients and describe the typical malformations. Patients and Methods. Conventional radiological examination of 95 skeletally mature patients with NPS was performed. Patellar morphology was classified according to the Wiberg classification as modified by Baumgartl and Ficat criteria, and trochlear shape was classified according to the Dejour classification. Results. Patellar aplasia was present in 4/90 (4%), and patellar hypoplasia in 77/90 (86%) of patients. The prevailing patellar shapes were type III, type IV and Hunter’s cap. No patellar shape genotype-phenotype association could be found. The malformations of the distal femur comprised shortening of the lateral femoral condyle in 46 out of 84 patients (55%), with a prominent anterior surface of the lateral femoral condyle in 47 out of 84 patients (56%) and a flat anterior surface of the medial femoral condyle in 78 out of 85 patients (92%). The trochlea was type A1 according to the Dejour classification in 79 out of 85 patients (93%). . Conclusion. An easily recognisable characteristic quartet of malformations consisting of patellar aplasiaor hypoplasia and the malformations of the distal femur was found in 22 out of 81 patients (27%), with the majority displaying at least three malformations. Take home message: The distinct malformations of the knee in nail patella syndrome are easily recognisable on conventional radiographs and lead to the correct interpretation of the aberrant morphology which is essential in the treatment of these patellofemoral disorders. Cite this article: Bone Joint J 2016;98-B:483–9


Bone & Joint Open
Vol. 3, Issue 8 | Pages 656 - 665
23 Aug 2022
Tran T McEwen P Peng Y Trivett A Steele R Donnelly W Clark G

Aims. The mid-term results of kinematic alignment (KA) for total knee arthroplasty (TKA) using image derived instrumentation (IDI) have not been reported in detail, and questions remain regarding ligamentous stability and revisions. This paper aims to address the following: 1) what is the distribution of alignment of KA TKAs using IDI; 2) is a TKA alignment category associated with increased risk of failure or poor patient outcomes; 3) does extending limb alignment lead to changes in soft-tissue laxity; and 4) what is the five-year survivorship and outcomes of KA TKA using IDI?. Methods. A prospective, multicentre, trial enrolled 100 patients undergoing KA TKA using IDI, with follow-up to five years. Alignment measures were conducted pre- and postoperatively to assess constitutional alignment and final implant position. Patient-reported outcome measures (PROMs) of pain and function were also included. The Australian Orthopaedic Association National Joint Arthroplasty Registry was used to assess survivorship. Results. The postoperative HKA distribution varied from 9° varus to 11° valgus. All PROMs showed statistical improvements at one year (p < 0.001), with further improvements at five years for Knee Osteoarthritis Outcome Score symptoms (p = 0.041) and Forgotten Joint Score (p = 0.011). Correlation analysis showed no difference (p = 0.610) between the hip-knee-ankle and joint line congruence angle at one and five years. Sub-group analysis showed no difference in PROMs for patients placed within 3° of neutral compared to those placed > 3°. There were no revisions for tibial loosening; however, there were reports of a higher incidence of poor patella tracking and patellofemoral stiffness. Conclusion. PROMs were not impacted by postoperative alignment category. Ligamentous stability was maintained at five years with joint line obliquity. There were no revisions for tibial loosening despite a significant portion of tibiae placed in varus; however, KA executed with IDI resulted in a higher than anticipated rate of patella complications. Cite this article: Bone Jt Open 2022;3(8):656–665


Bone & Joint Open
Vol. 2, Issue 12 | Pages 1075 - 1081
17 Dec 2021
Suthar A Yukata K Azuma Y Suetomi Y Yamazaki K Seki K Sakai T Fujii H

Aims. This study aimed to investigate the relationship between changes in patellar height and clinical outcomes at a mean follow-up of 7.7 years (5 to 10) after fixed-bearing posterior-stabilized total knee arthroplasty (PS-TKA). Methods. We retrospectively evaluated knee radiographs of 165 knees, which underwent fixed-bearing PS-TKA with patella resurfacing. The incidence of patella baja and changes in patellar height over a minimum of five years of follow-up were determined using Insall-Salvati ratio (ISR) measurement. We examined whether patella baja (ISR < 0.8) at final follow-up affected clinical outcomes, knee joint range of motion (ROM), and Knee Society Score (KSS). We also assessed inter- and intrarater reliability of ISR measurements and focused on the relationship between patellar height reduction beyond measurement error and clinical outcomes. Results. The ISR gradually decreased over five years after TKA, and finally 33 patients (20.0%) had patella baja. Patella baja at the final follow-up was not related to passive knee ROM or KSS. Interestingly, when we divided into two groups - patella baja and patella normal-alta (ISR ≥ 0.8) - the patella baja group already had a lower patellar height before surgery, compared with the patella normal-alta group. The ISR measurement error in this study was 0.17. Both passive knee flexion and KSS were significantly decreased in the group with a decrease in ISR of ≥ 0.17 at final follow-up. Conclusion. Patellar height gradually decreased over five years of follow-up after TKA. The reduction in patellar height beyond measurement error following TKA was associated with lower clinical outcomes. Cite this article: Bone Jt Open 2021;2(12):1075–1081


Bone & Joint Open
Vol. 4, Issue 8 | Pages 621 - 627
22 Aug 2023
Fishley WG Paice S Iqbal H Mowat S Kalson NS Reed M Partington P Petheram TG

Aims. The rate of day-case total knee arthroplasty (TKA) in the UK is currently approximately 0.5%. Reducing length of stay allows orthopaedic providers to improve efficiency, increase operative throughput, and tackle the rising demand for joint arthroplasty surgery and the COVID-19-related backlog. Here, we report safe delivery of day-case TKA in an NHS trust via inpatient wards with no additional resources. Methods. Day-case TKAs, defined as patients discharged on the same calendar day as surgery, were retrospectively reviewed with a minimum follow-up of six months. Analysis of hospital and primary care records was performed to determine readmission and reattendance rates. Telephone interviews were conducted to determine patient satisfaction. Results. Since 2016, 301/7350 TKAs (4.1%) in 290 patients at our institution were discharged on the day of surgery. Mean follow-up was 31.4 months (6.2 to 70.0). In all, 28 patients (9.3%) attended the emergency department or other acute care settings within 90 days of surgery, most often with wound concerns or leg swelling; six patients (2.0%) were readmitted. No patients underwent a subsequent revision procedure, and there were no periprosthetic infections. Two patients (0.7%) underwent secondary patella resurfacing, and one patient underwent arthroscopic arthrolysis after previous manipulation under anaesthetic (MUA). Three patients (1.0%) underwent MUA alone. Primary care consultation records, available for 206 patients, showed 16 patients (7.8%) contacted their general practitioner within two weeks postoperatively; two (1.0%) were referred to secondary care. Overall, 115/121 patients (95%) telephoned stated they would have day-case TKA again. Conclusion. Day-case TKA can be safely delivered in the NHS with no additional resources. We found low incidence of contact with primary and secondary care in the postoperative period, and high patient satisfaction. Cite this article: Bone Jt Open 2023;4(8):621–627


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 6 | Pages 761 - 765
1 Jun 2007
Barnett AJ Gardner ROE Lankester BJA Wakeley CJ Eldridge JDJ

We retrospectively analysed the MR scans of 25 patients with patellofemoral dysplasia and ten control subjects, to assess whether there was any change in the morphology of the patella along its vertical length. Ratios were calculated comparing the size of the cartilaginous and subchondral osseous surfaces of the lateral and medial facets. We also classified the morphology using the scoring systems of Baumgartl and Wiberg. There were 18 females and seven males with a mean age of 20.2 years (10 to 29) with dysplasia and two females and eight males with a mean age of 20.4 years (10 to 29) in the control group. In the patient group there was a significant difference in morphology from proximal to distal for the cartilaginous (Analysis of variance (ANOVA) p = 0.004) and subchondral osseous surfaces (ANOVA, p = 0.002). In the control group there was no significant difference for either the cartilaginous (ANOVA, p = 0.391) or the subchondral osseous surface (ANOVA, p = 0.526). Our study has shown that in the dysplastic patellofemoral articulation the medial facet of the patella becomes smaller in relation to the lateral facet from proximal to distal. MRI is needed to define clearly the cartilaginous and osseous morphology of the patella before surgery is considered for patients with patellofemoral dysplasia


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 344 - 350
1 Mar 2009
Luyckx T Didden K Vandenneucker H Labey L Innocenti B Bellemans J

The purpose of this study was to test the hypothesis that patella alta leads to a less favourable situation in terms of patellofemoral contact force, contact area and contact pressure than the normal patellar position, and thereby gives rise to anterior knee pain. A dynamic knee simulator system based on the Oxford rig and allowing six degrees of freedom was adapted in order to simulate and record the dynamic loads during a knee squat from 30° to 120° flexion under physiological conditions. Five different configurations were studied, with variable predetermined patellar heights. The patellofemoral contact force increased with increasing knee flexion until contact occurred between the quadriceps tendon and the femoral trochlea, inducing load sharing. Patella alta caused a delay of this contact until deeper flexion. As a consequence, the maximal patellofemoral contact force and contact pressure increased significantly with increasing patellar height (p < 0.01). Patella alta was associated with the highest maximal patellofemoral contact force and contact pressure. When averaged across all flexion angles, a normal patellar position was associated with the lowest contact pressures. Our results indicate that there is a biomechanical reason for anterior knee pain in patients with patella alta


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 6 | Pages 752 - 760
1 Jun 2007
Yamada Y Toritsuka Y Horibe S Sugamoto K Yoshikawa H Shino K

We used three-dimensional movement analysis by computer modelling of knee flexion from 0° to 50° in 14 knees in 12 patients with recurrent patellar dislocation and in 15 knees in ten normal control subjects to compare the in vivo three-dimensional movement of the patella. Flexion, tilt and spin of the patella were described in terms of rotation angles from 0°. The location of the patella and the tibial tubercle were evaluated using parameters expressed as percentage patellar shift and percentage tubercle shift. Patellar inclination to the femur was also measured and patellofemoral contact was qualitatively and quantitatively analysed. The patients had greater values of spin from 20° to 50°, while there were no statistically significant differences in flexion and tilt. The patients also had greater percentage patellar shift from 0° to 50°, percentage tubercle shift at 0° and 10° and patellar inclination from 0° to 50° with a smaller oval-shaped contact area from 20° to 50° moving downwards on the lateral facet. Patellar movement analysis using a three-dimensional computer model is useful to clearly demonstrate differences between patients with recurrent dislocation of the patella and normal control subjects


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1265 - 1270
1 Dec 2023
Hurley ET Sherman SL Chahla J Gursoy S Alaia MJ Tanaka MJ Pace JL Jazrawi LM

Aims

The aim of this study was to establish consensus statements on medial patellofemoral ligament (MPFL) reconstruction, anteromedialization tibial tubercle osteotomy, trochleoplasty, and rehabilitation and return to sporting activity in patients with patellar instability, using the modified Delphi process.

Methods

This was the second part of a study dealing with these aspects of management in these patients. As in part I, a total of 60 surgeons from 11 countries contributed to the development of consensus statements based on their expertise in this area. They were assigned to one of seven working groups defined by subtopics of interest. Consensus was defined as achieving between 80% and 89% agreement, strong consensus was defined as between 90% and 99% agreement, and 100% agreement was considered unanimous.


The Bone & Joint Journal
Vol. 104-B, Issue 5 | Pages 613 - 619
2 May 2022
Ackerman IN Busija L Lorimer M de Steiger R Graves SE

Aims

This study aimed to describe the use of revision knee arthroplasty in Australia and examine changes in lifetime risk over a decade.

Methods

De-identified individual-level data on all revision knee arthroplasties performed in Australia from 2007 to 2017 were obtained from the Australian Orthopaedic Association National Joint Replacement Registry. Population data and life tables were obtained from the Australian Bureau of Statistics. The lifetime risk of revision surgery was calculated for each year using a standardized formula. Separate calculations were undertaken for males and females.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1172 - 1177
1 Sep 2007
Benoit B Laflamme GY Laflamme GH Rouleau D Delisle J Morin B

We retrospectively reviewed the operative treatment carried out between 1988 and 1994 of eight patients with habitual patellar dislocation. In four the condition was bilateral. All patients had recurrent dislocation with severe functional disability. The surgical technique involved distal advancement of the patella by complete mobilisation of the patellar tendon, lateral release and advancement of vastus medialis obliquus. The long-term results were assessed radiologically, clinically and functionally using the Lysholm knee score, by an independent observer. The mean age at operation was 10.3 years (7 to 14) with a mean follow-up of 13.5 years (11 to 16). One patient required revision. At the latest follow-up, all patellae were stable and knees functional with a mean Lysholm knee score of 98 points (95 to 100). In those aged younger than ten years at operation there was a statistically significant improvement in the sulcus angle at the latest follow-up (Student’s t-test, p = 0.001). Two patients developed asymptomatic patella infera as a late complication. This technique offers a satisfactory treatment for the immature patient presenting with habitual patellar dislocation associated with patella alta. If performed early, we believe that remodelling of the shallow trochlea may occur, adding intrinsic patellofemoral stability


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 6 | Pages 746 - 751
1 Jun 2007
Yamada Y Toritsuka Y Yoshikawa H Sugamoto K Horibe S Shino K

We investigated the three-dimensional morphological differences of the articular surface of the femoral trochlea in patients with recurrent dislocation of the patella and a normal control group using three-dimensional computer models. There were 12 patients (12 knees) and ten control subjects (ten knees). Three-dimensional computer models of the femur, including the articular cartilage, were created. Evaluation was performed on the shape of the articular surface, focused on its convexity, and the proximal and mediolateral distribution of the articular cartilage of the femoral trochlea. The extent of any convexity, and the proximal distribution of the articular cartilage, expressed as the height, were shown by the angles about the transepicondylar axis. The mediolateral distribution of the articular cartilage was assessed by the location of the medial and lateral borders of the articular cartilage. The mean extent of convexity was 24.9° . sd. 6.7° for patients and 11.9° . sd. 3.6° for the control group (p < 0.001). The mean height of the articular cartilage was 91.3° . sd. 8.3° for the patients and 83.3° . sd. 7.7° for the control group (p = 0.03), suggesting a wider convex trochlea in the patients with recurrent dislocation of the patella caused by the proximally-extended convex area. The lateral border of the articular cartilage of the trochlea in the patients was more laterally located than in the control group. Our findings therefore quantitatively demonstrated differences in the shape and distribution of the articular cartilage on the femoral trochlea between patients with dislocation of the patella and normal subjects


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 6 | Pages 965 - 970
1 Nov 1998
Meister K Cobb A Bentley G

Between 1989 and 1993 we implanted a matrix support prosthesis made of carbon fibre for the treatment of chronic painful articular defects of the patella in 27 patients. The mean period of follow-up was 33 months (11 to 54) with clinical and arthroscopic evaluation of the implant. Overall, there were four excellent, three good, seven fair and 13 poor results. Nine patients subsequently had a patellectomy for persistent pain at a mean of 27 months after surgery (14 to 47). The mean visual analogue pain scores in those who retained their patella were 7.6 before operation and 5.5 at the time of the latest follow-up. Patient satisfaction for the entire group was 41%. There appeared to be good incorporation of the prosthesis and a satisfactory ingrowth of fibrocartilage, but the poor results in 48% and low patient satisfaction discourage us from recommending the procedure for lesions of the articular cartilage of the patella. The consistent seeding of the joint with carbon-fibre debris and a histiocytic giant-cell reaction in the synovium are also a cause for concern


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 5 | Pages 675 - 678
1 Jul 2003
Muoneke HE Khan AM Giannikas KA Hägglund E Dunningham TH

Out of a total of 623 patients who, over a ten-year period, underwent primary total knee replacement (TKR) without patellar resurfacing, 20 underwent secondary resurfacing for chronic anterior knee pain. They were evaluated pre- and postoperatively using the clinical and radiological American Knee Society score. The mean follow-up was 36.1 months (12 to 104). The mean knee score improved from 46.7 to 62.2 points and the mean functional score from 44.7 to 52.2 points. Only 44.4% of the patients, however, reported some improvement; the remainder reported no change or deterioration. The radiographic alignment of the TKR did not influence the outcome of secondary resurfacing of the patella. Complications were noted in six of the 20 patients including fracture and instability of the patella and loss of movement. Anterior knee pain after TKR remains difficult to manage. Secondary resurfacing of the patella is not advocated in all patients since it may increase patient dissatisfaction and hasten revision


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 6 | Pages 861 - 864
1 Aug 2002
Nakagawa K Wada Y Minamide M Tsuchiya A Moriya H

We examined an39 patients (45 knees) who had undergone Elmslie-Trillat procedure for recurrent or habitual dislocation of the patella with a follow-up of more than ten years. The mean age at the time of surgery was 18.4 years; the mean follow-up was 161 months (120 to 238). Using Fulkerson’s functional knee score, 41 knees (91%) had an excellent or good result at a mean follow-up of 45 months, and this was maintained in 29 (64%) at the final review. The main cause of deterioration in the clinical results was the onset or worsening of patellofemoral joint pain, not patellar instability


Bone & Joint Open
Vol. 5, Issue 7 | Pages 592 - 600
18 Jul 2024
Faschingbauer M Hambrecht J Schwer J Martin JR Reichel H Seitz A

Aims. Patient dissatisfaction is not uncommon following primary total knee arthroplasty. One proposed method to alleviate this is by improving knee kinematics. Therefore, we aimed to answer the following research question: are there significant differences in knee kinematics based on the design of the tibial insert (cruciate-retaining (CR), ultra-congruent (UC), or medial congruent (MC))?. Methods. Overall, 15 cadaveric knee joints were examined with a CR implant with three different tibial inserts (CR, UC, and MC) using an established knee joint simulator. The effects on coronal alignment, medial and lateral femoral roll back, femorotibial rotation, bony rotations (femur, tibia, and patella), and patellofemoral length ratios were determined. Results. No statistically significant differences were found regarding coronal alignment (p = 0.087 to p = 0.832). The medial congruent insert demonstrated restricted femoral roll back (mean medial 37.57 mm; lateral 36.34 mm), while the CR insert demonstrated the greatest roll back (medial 42.21 mm; lateral 37.88 mm; p < 0.001, respectively). Femorotibial rotation was greatest with the CR insert with 2.45° (SD 4.75°), then the UC insert with 1.31° (SD 4.15°; p < 0.001), and lowest with the medial congruent insert with 0.8° (SD 4.24°; p < 0.001). The most pronounced patella shift, but lowest patellar rotation, was noted with the CR insert. Conclusion. The MC insert demonstrated the highest level of constraint of these inserts. Femoral roll back, femorotibial rotation, and single bony rotations were lowest with the MC insert. The patella showed less shifting with the MC insert, but there was significantly increased rotation. While the medial congruent insert was found to have highest constraint, it remains uncertain if this implant recreates native knee kinematics or if this will result in improved patient satisfaction. Cite this article: Bone Jt Open 2024;5(7):592–600


The Bone & Joint Journal
Vol. 103-B, Issue 10 | Pages 1555 - 1560
4 Oct 2021
Phillips JRA Tucker K

Aims. Knee arthroplasty surgery is a highly effective treatment for arthritis and disorders of the knee. There are a wide variety of implant brands and types of knee arthroplasty available to surgeons. As a result of a number of highly publicized failures, arthroplasty surgery is highly regulated in the UK and many other countries through national registries, introduced to monitor implant performance, surgeons, and hospitals. With time, the options available within many brand portfolios have grown, with alternative tibial or femoral components, tibial insert materials, or shapes and patella resurfacings. In this study we have investigated the effect of the expansion of implant brand portfolios and where there may be a lack of transparency around a brand name. We also aimed to establish the potential numbers of compatible implant construct combinations. Methods. Hypothetical implant brand portfolios were proposed, and the number of compatible implant construct combinations was calculated. Results. A simple knee portfolio with cemented cruciate-retaining (CR) and posterior-stabilized (PS) components, with and without a patella, has four combinations. If there are two options available for each component, the numbers double for each option, resulting in 32 combinations. The effect of adding a third option multiplies the number by 1.3. Introducing compatible uncemented options, with the effect of hybrids, multiplies the number by 4. An implant portfolio with two femoral components (both in CR and PS), with two insert options and a patella, all in cemented and uncemented versions leads to 192 possible compatible implant construct combinations. There are implant brands available to surgeons with many more than two options. Conclusion. This study demonstrates that the addition of multiple variants within a knee brand portfolio leads to a large number (many hundreds) of compatible implant construct combinations. Revision rates of implant combinations are not currently reviewed at this level of granularity, leading to the risk of camouflage of true outcomes. Cite this article: Bone Joint J 2021;103-B(10):1555–1560


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 864 - 871
3 May 2021
Hunt LP Matharu GS Blom AW Howard PW Wilkinson JM Whitehouse MR

Aims. Debate remains whether the patella should be resurfaced during total knee replacement (TKR). For non-resurfaced TKRs, we estimated what the revision rate would have been if the patella had been resurfaced, and examined the risk of re-revision following secondary patellar resurfacing. Methods. A retrospective observational study of the National Joint Registry (NJR) was performed. All primary TKRs for osteoarthritis alone performed between 1 April 2003 and 31 December 2016 were eligible (n = 842,072). Patellar resurfacing during TKR was performed in 36% (n = 305,844). The primary outcome was all-cause revision surgery. Secondary outcomes were the number of excess all-cause revisions associated with using TKRs without (versus with) patellar resurfacing, and the risk of re-revision after secondary patellar resurfacing. Results. The cumulative risk of all-cause revision at ten years was higher (p < 0.001) in primary TKRs without patellar resurfacing (3.54% (95% confidence interval (CI) 3.47 to 3.62)) compared to those with resurfacing (3.00% (95% CI 2.91 to 3.11)). Using flexible parametric survival modelling, we estimated one ‘excess’ revision per 189 cases performed where the patella was not resurfaced by ten years (equivalent to 2,842 excess revisions in our cohort). The risk of all-cause re-revision following secondary patellar resurfacing was 4.6 times higher than the risk of revision after primary TKR with patellar resurfacing (at five years from secondary patellar resurfacing, 8.8% vs 1.9%). Conclusion. Performing TKR without patellar resurfacing was associated with an increased risk of revision. Secondary patellar resurfacing led to a high risk of re-revision. This represents a potential substantial healthcare burden that should be considered when forming treatment guidelines and commissioning services. Cite this article: Bone Joint J 2021;103-B(5):864–871


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 622 - 634
1 Jun 2023
Simpson CJRW Wright E Ng N Yap NJ Ndou S Scott CEH Clement ND

Aims. This systematic review and meta-analysis aimed to compare the influence of patellar resurfacing following cruciate-retaining (CR) and posterior-stabilized (PS) total knee arthroplasty (TKA) on the incidence of anterior knee pain, knee-specific patient-reported outcome measures, complication rates, and reoperation rates. Methods. A systematic review of MEDLINE, PubMed, and Google Scholar was performed to identify randomized controlled trials (RCTs) according to search criteria. Search terms used included: arthroplasty, replacement, knee (Mesh), TKA, prosthesis, patella, patellar resurfacing, and patellar retaining. RCTs that compared patellar resurfacing versus unresurfaced in primary TKA were included for further analysis. Studies were evaluated using the Scottish Intercollegiate Guidelines Network assessment tool for quality and minimization of bias. Data were synthesized and meta-analysis performed. Results. There were 4,135 TKAs (2,068 resurfaced and 2,027 unresurfaced) identified in 35 separate cohorts from 33 peer-reviewed studies. Anterior knee pain rates were significantly higher in unresurfaced knees overall (odds ratio (OR) 1.84; 95% confidence interval (CI) 1.20 to 2.83; p = 0.006) but more specifically associated with CR implants (OR 1.95; 95% CI 1.0 to 3.52; p = 0.030). There was a significantly better Knee Society function score (mean difference (MD) -1.98; 95% CI -1.1 to -2.84; p < 0.001) and Oxford Knee Score (MD -2.24; 95% CI -0.07 to -4.41; p = 0.040) for PS implants when patellar resurfacing was performed, but these differences did not exceed the minimal clinically important difference for these scores. There were no significant differences in complication rates or infection rates according to implant design. There was an overall significantly higher reoperation rate for unresurfaced TKA (OR 1.46 (95% CI 1.04 to 2.06); p = 0.030) but there was no difference between PS or CR TKA. Conclusion. Patellar resurfacing, when performed with CR implants, resulted in lower rates of anterior knee pain and, when used with a PS implant, yielded better knee-specific functional outcomes. Patellar resurfacing was associated with a lower risk of reoperation overall, but implant type did not influence this. Cite this article: Bone Joint J 2023;105-B(6):622–634


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1279 - 1285
1 Dec 2023
Baker JF Nadar AC Jouflas AC Smith LS Sachdeva S Yakkanti MR Malkani AL

Aims. The use of cementless total knee arthroplasty (TKA) components has increased during the past decade. The initial design of cementless metal-backed patellar components had shown high failure rates due to many factors. The aim of this study was to evaluate the clinical results of a second-generation cementless, metal-backed patellar component of a modern design. Methods. This was a retrospective review of 707 primary TKAs in 590 patients from a single institution, using a cementless, metal-backed patellar component with a mean follow-up of 6.9 years (2 to 12). A total of 409 TKAs were performed in 338 females and 298 TKAs in 252 males. The mean age of the patients was 63 years (34 to 87) and their mean BMI was 34.3 kg/m. 2. (18.8 to 64.5). The patients were chosen to undergo a cementless procedure based on age and preoperative radiological and intraoperative bone quality. Outcome was assessed using the Knee Society knee and function scores and range of motion (ROM), complications, and revisions. Results. A total of 24 TKAs (3.4%) in 24 patients failed and required revision surgery, of which five were due to patellar complications (0.71%): one for aseptic patellar loosening (0.14%) and four for polyethylene dissociation (0.57%). A total of 19 revisions (2.7%) were undertaken in 19 patients for indications which did not relate to the patella: four for aseptic tibial loosening (0.57%), one for aseptic femoral loosening (0.14%), nine for periprosthetic infection (1.3%), one for popliteus impingement (0.14%), and four for instability (0.57%). Knee Society knee and function scores, and ROM, improved significantly when comparing pre- and postoperative values. Survival of the metal-backed patellar component for all-cause failure was 97.5% (95% confidence interval 94.9% to 100%) at 12 years. Conclusion. The second-generation cementless TKA design of metal-backed patellar components showed a 97.5% survival at 12 years, with polyethylene dissociation from the metal-backing being the most common cause of patellar failure. In view of the increased use of TKA, especially in younger, more active, or obese patients, these findings are encouraging at mean follow-up of seven years. Cite this article: Bone Joint J 2023;105-B(12):1279–1285


Aims. The aim of this study was to evaluate medium-term outcomes and complications of the S-ROM NOILES Rotating Hinge Knee System (DePuy, USA) in revision total knee arthroplasty (rTKA) at a tertiary unit. Methods. A retrospective consecutive study of all patients who underwent a rTKA using this implant from January 2005 to December 2018. Outcome measures included reoperations, revision for any cause, complications, and survivorship. Patients and implant survivorship data were identified through both local hospital electronic databases and linked data from the National Joint Registry/NHS Personal Demographic Service. Kaplan-Meier survival analysis was used at ten years. Results. A total of 89 consecutive patients (89 knees) were included with 47 females (52.8%) and a median age of 74 years (interquartile range 66 to 79). The main indications were aseptic loosening with instability (39.4%; n = 35) and infection (37.1%; n = 33) with the majority of patients managed through two-stage approach. The mean follow-up was 7.4 years (2 to 16). The overall rate of reoperation, for any cause, was 10.1% (n = 9) with a rate of implant revision of 6.7% (n = 6). Only two cases required surgery for patellofemoral complications. Kaplan-Meier implant-survivorship analysis was 93.3% at ten years, using revision for any cause as an endpoint. Conclusion. This implant achieved high ten-year survivorship with a low complication rate, particularly patellofemoral complications. These can be avoided by ensuring central patella tracking and appropriate tension of the patellofemoral joint in this posterior hinge design. Cite this article: Bone Jt Open 2022;3(3):205–210