Advertisement for orthosearch.org.uk
Results 1 - 20 of 190
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 50 - 56
1 Jan 2007
Yang KGA Raijmakers NJH Verbout AJ Dhert WJA Saris DBF

This study validates the short-form WOMAC function scale for assessment of conservative treatment of osteoarthritis of the knee. Data were collected before treatment and six and nine months later, from 100 patients with osteoarthritis of the knee to determine the validity, internal consistency, test-retest reliability, floor and ceiling effects, and responsiveness of the short-form WOMAC function scale. The scale showed high correlation with the traditional WOMAC and other measures. The internal consistency was good (Cronbach α: 0.88 to 0.95) and an excellent test-retest reliability was found (Lin’s concordance correlation coefficient (ρ. c. ): 0.85 to 0.94). The responsiveness was adequate and comparable to that of the traditional WOMAC (standardised response mean 0.56 to 0.44 and effect size 0.64 to 0.57) and appeared not to be significantly affected by floor or ceiling effects (0% and 7%, respectively). The short-form WOMAC function scale is a valid, reliable and responsive alternative to the traditional WOMAC in the evaluation of patients with osteoarthritis of the knee managed conservatively. It is simple to use in daily practice and is therefore less of a burden for patients in clinical trials


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 7 | Pages 901 - 903
1 Jul 2007
McDonnell SM Sinsheimer J Price AJ Carr AJ

We report a study of 112 patients with primary anteromedial osteoarthritis of the knee and their families. Sibling risk was determined using randomly selected single siblings. Spouses were used as controls. The presence of symptomatic osteoarthritis was determined using an Oxford knee score of ≥ 29 supported by a Kellgren and Lawrence radiological score of II or greater. Using Fisher’s exact test we found that there was a significant increased risk of anteromedial osteoarthritis (OA) relative to the control group (p = 0.031). The recurrence risk of anteromedial OA to siblings was 3.21 (95% confidence interval 1.12 to 9.27). These findings imply that genetic factors may play a major role in the development of anteromedial OA of the knee


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 3 | Pages 449 - 451
1 May 1999
Magyar G Toksvig-Larsen S Lindstrand A

We studied the complications after open-wedge osteotomy by hemicallotasis in 308 consecutive patients, most of whom had osteoarthritis of the knee. The participating surgeons, who worked at 17 hospitals, used their discretion in selecting patients, operating techniques and external fixators. The general complications included 11 cases of deep-vein thrombosis (4%), six of nonunion (2%) and one of septic arthritis of the knee. There were technical complications in 13 patients (4%). In 157 patients (51%) pin-site infections were recorded; of these, 96% were minor and responded to wound toilet and antibiotic treatment. A total of 18 revision procedures was carried out


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 3 | Pages 432 - 436
1 May 1998
Terauchi M Shirakura K Katayama M Higuchi H Takagishi K

We studied 37 patients with varus osteoarthritis of the knee to determine the influence of the bone mineral density (BMD) on the varus deformity. There were 15 men (21 knees) and 22 women (38 knees). The mean age of the men was 69 years and of the women 68 years. BMD was measured in the L1–L4 spinal region using dual X-ray absorptiometry. In the women a low level of BMD was associated with varus deformity originating at the proximal tibia, but a high level was predominantly linked with deformity originating in the joint space. Similar findings were obtained in the men. Our results suggest that a low BMD predisposes to trabecular microfractures and consequently increased stress on the articular cartilage. A low BMD does not preclude osteoarthritic change in the knee


Bone & Joint Research
Vol. 1, Issue 9 | Pages 205 - 209
1 Sep 2012
Atrey A Morison Z Tosounidis T Tunggal J Waddell JP

We systematically reviewed the published literature on the complications of closing wedge high tibial osteotomy for the treatment of unicompartmental osteoarthritis of the knee. Publications were identified using the Cochrane Library, MEDLINE, EMBASE and CINAHL databases up to February 2012. We assessed randomised (RCTs), controlled group clinical (CCTs) trials, case series in publications associated with closing wedge osteotomy of the tibia in patients with osteoarthritis of the knee and finally a Cochrane review. Many of these trials included comparative studies (opening wedge versus closing wedge) and there was heterogeneity in the studies that prevented pooling of the results


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1517 - 1521
1 Nov 2012
Niinimäki TT Eskelinen A Mann BS Junnila M Ohtonen P Leppilahti J

Previous studies from single centres or single-surgeon series report good early and mid-term results for high tibial osteotomy (HTO) in the treatment of osteoarthritis of the knee. However, the survivorship of HTO at a national level is unknown. This registry-based study included 3195 high HTOs performed between 1987 and 2008. Kaplan-Meier analysis revealed an overall survivorship of 89% (95% confidence interval (CI) 88 to 90) at five years and 73% (95% CI 72 to 75) at ten years, when conversion to total knee replacement was taken as the endpoint. Females and patients aged > 50 years had worse survivorship than males or patients aged ≤ 50 years (hazard ratio (HR) 1.26 (95% CI 1.11 to 1.43) and HR 1.41 (95% CI 1.23 to 1.64), respectively). The survivorship of HTOs performed between 1998 to 2008 was worse than for those performed between 1987 and 1997


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 3 | Pages 444 - 448
1 May 1999
Magyar G Ahl TL Vibe P Toksvig-Larsen S Lindstrand A

We describe the results of 50 operations carried out on 46 patients with medial osteoarthritis of the knee of Ahlbäck grade 1 to 3. Patients were randomised either to a closed-wedge high tibial osteotomy (HTO) or an open-wedge procedure based on the hemicallotasis technique (HCO). Their median age was 55 years (38 to 68). The preoperative median hip-knee-ankle (HKA) angle was 171° (164 to 176) in the HTO group and 173° (165 to 179) in the HCO group. After six weeks, the median HKA angle was 185° (176 to 194) in the HTO group and 184° (181 to 188) in the HCO group. In the HTO group, seven patients were within the range of 182° to 186° compared with 21 in the HCO group (p < 0.001). One year later, ten HTO patients were within this range while the HKA angulation in the HCO group was unchanged. At two years the numbers were 11 and 18, respectively. We evaluated the clinical results on the Hospital for Special Surgery, Lysholm and Wallgren-Tegner activity scores, and patients completed part of the Nottingham Health Profile questionnaire. An impartial observer at the two-year follow-up concluded that all scores had improved, but found no clinical differences between the groups


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 10 | Pages 1336 - 1340
1 Oct 2006
Aoki Y Yasuda K Mikami S Ohmoto H Majima T Minami A

We compared the results ten years after an inverted V-shaped high tibial osteotomy with those of a historical series of conventional closing-wedge osteotomies. The closing-wedge series consisted of 56 knees in 51 patients with a mean follow-up of 11 years (10 to 15). The inverted V-shaped osteotomy was evaluated in 48 knees in 43 patients at a mean follow-up of 14 years (10 to 19). All the patients were scored using the Japanese Orthopaedic Association rating scale for osteoarthritis of the knee and radiological assessment. The pre-operative grade of osteoarthritis was similar in both groups. Post-operatively, the knee function score was graded as satisfactory in 63% (35) of the closing-wedge group but in 89% (43) of the inverted V-shaped osteotomy group. Post-operative radiological examination showed that delayed union and loss of correction occurred more often after a closing-wedge osteotomy than after an inverted V-shaped procedure. Our study suggests that the inverted V-shaped osteotomy may offer more dependable long-term results than traditional closing-wedge osteotomy


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 1 | Pages 42 - 47
1 Jan 2002
Brismar BH Wredmark T Movin T Leandersson J Svensson O

We studied 19 videotaped knee arthroscopies in 19 patients with mild to moderate osteoarthritis (OA) of the knee in order to compare the intraobserver and interobserver reliability and the patterns of disagreement between four orthopaedic surgeons. The classifications of OA of Collins, Outerbridge and the French Society of Arthroscopy were used. Intraobserver and interobserver agreements using kappa measures were 0.42 to 0.66 and 0.43 to 0.49, respectively. Only 6% to 8% of paired intraobserver classifications differed by more than one category. Observer-specific disagreement was evident both within and between observers. A small, but significant, occasional variation was also seen. Although reliability may improve by an analysis of disagreement, it appears that the arthroscopic grading of early osteoarthritic lesions is inexact


The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 716 - 726
1 Jun 2020
Scott CEH Holland G Krahelski O Murray IR Keating JF Keenan OJF

Aims

This study aims to determine the proportion of patients with end-stage knee osteoarthritis (OA) possibly suitable for partial (PKA) or combined partial knee arthroplasty (CPKA) according to patterns of full-thickness cartilage loss and anterior cruciate ligament (ACL) status.

Methods

A cross-sectional analysis of 300 consecutive patients (mean age 69 years (SD 9.5, 44 to 91), mean body mass index (BMI) 30.6 (SD 5.5, 20 to 53), 178 female (59.3%)) undergoing total knee arthroplasty (TKA) for Kellgren-Lawrence grade ≥ 3 knee OA was conducted. The point of maximal tibial bone loss on preoperative lateral radiographs was determined as a percentage of the tibial diameter. At surgery, Lachman’s test and ACL status were recorded. The presence of full-thickness cartilage loss within 16 articular surface regions (two patella, eight femoral, six tibial) was recorded.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 1 | Pages 43 - 47
1 Jan 2004
Ritter MA Faris PM Thong AE Davis KE Meding JB Berend ME

Interest in unicompartmental knee arthroplasty (UKA) for the treatment of medial compartment osteoarthritis has increased in recent years with apparent improvement in the long-term results. This is a result of improved surgical technique, patient selection, and implant design. In an effort further to improve patient selection we analysed the relationship between the pre-operative alignment of the knee and the anatomical findings at the time of surgery. We compared these findings with the indications for UKA.

From 4021 total knee arthroplasties we compared intra-operative observations with the pre-operative clinical data in order to identify knees with isolated, medial, compartment changes, which would have been ideal candidates for UKA.

We found that only 247 of the knees (6.1%) met anatomical qualifications for isolated, medial, unicompartmental osteoarthritis, and of these, only 168 (4.3%) met clinical standards ideal for UKA. Pre-operative alignment showed a significant relationship with patterns of disease. Logistic regression revealed a relationship between pre-operative alignment and intra-operative findings resembling a Gaussian distribution. Patients with a pre-operative varus alignment of 7° were slightly more likely to be selected for UKA. But the further the anatomical alignment in either direction varies from 7° of varus, the more unlikely it is for the knee to exhibit a disease pattern of isolated, medial, unicompartmental osteoarthritis.


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 436 - 444
1 Apr 2013
Scott CEH Nutton RW Biant LC

The lateral compartment is predominantly affected in approximately 10% of patients with osteoarthritis of the knee. The anatomy, kinematics and loading during movement differ considerably between medial and lateral compartments of the knee. This in the main explains the relative protection of the lateral compartment compared with the medial compartment in the development of osteoarthritis. The aetiology of lateral compartment osteoarthritis can be idiopathic, usually affecting the femur, or secondary to trauma commonly affecting the tibia. Surgical management of lateral compartment osteoarthritis can include osteotomy, unicompartmental knee replacement and total knee replacement. This review discusses the biomechanics, pathogenesis and development of lateral compartment osteoarthritis and its management. Cite this article: Bone Joint J 2013;95-B:436–44


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 601 - 607
1 May 2016
McClelland D Barlow D Moores TS Wynn-Jones C Griffiths D Ogrodnik PJ Thomas PBM

In arthritis of the varus knee, a high tibial osteotomy (HTO) redistributes load from the diseased medial compartment to the unaffected lateral compartment.

We report the outcome of 36 patients (33 men and three women) with 42 varus, arthritic knees who underwent HTO and dynamic correction using a Garches external fixator until they felt that normal alignment had been restored. The mean age of the patients was 54.11 years (34 to 68). Normal alignment was achieved at a mean 5.5 weeks (3 to 10) post-operatively. Radiographs, gait analysis and visual analogue scores for pain were measured pre- and post-operatively, at one year and at medium-term follow-up (mean six years; 2 to 10). Failure was defined as conversion to knee arthroplasty.

Pre-operative gait analysis divided the 42 knees into two equal groups with high (17 patients) or low (19 patients) adductor moments. After correction, a statistically significant (p < 0.001, t-test,) change in adductor moment was achieved and maintained in both groups, with a rate of failure of three knees (7.1%), and 89% (95% confidence interval (CI) 84.9 to 94.7) survivorship at medium-term follow-up.

At final follow-up, after a mean of 15.9 years (12 to 20), there was a survivorship of 59% (95% CI 59.6 to 68.9) irrespective of adductor moment group, with a mean time to conversion to knee arthroplasty of 9.5 years (3 to 18; 95% confidence interval ± 2.5).

HTO remains a useful option in the medium-term for the treatment of medial compartment osteoarthritis of the knee but does not last in the long-term.

Cite this article: Bone Joint J 2016;98-B:601–7.


The Bone & Joint Journal
Vol. 103-B, Issue 10 | Pages 1561 - 1570
1 Oct 2021
Blyth MJG Banger MS Doonan J Jones BG MacLean AD Rowe PJ

Aims. The aim of this study was to compare the clinical outcomes of robotic arm-assisted bi-unicompartmental knee arthroplasty (bi-UKA) with conventional mechanically aligned total knee arthroplasty (TKA) during the first six weeks and at one year postoperatively. Methods. A per protocol analysis of 76 patients, 43 of whom underwent TKA and 34 of whom underwent bi-UKA, was performed from a prospective, single-centre, randomized controlled trial. Diaries kept by the patients recorded pain, function, and the use of analgesics daily throughout the first week and weekly between the second and sixth weeks. Patient-reported outcome measures (PROMs) were compared preoperatively, and at three months and one year postoperatively. Data were also compared longitudinally and a subgroup analysis was conducted, stratified by preoperative PROM status. Results. Both operations were shown to offer comparable outcomes, with no significant differences between the groups across all timepoints and outcome measures. Both groups also had similarly low rates of complications. Subgroup analysis for preoperative psychological state, activity levels, and BMI showed no difference in outcomes between the two groups. Conclusion. Robotic arm-assisted, cruciate-sparing bi-UKA offered similar early clinical outcomes and rates of complications to a mechanically aligned TKA, both in the immediate postoperative period and up to one year following surgery. Further work is required to identify which patients with osteoarthritis of the knee will derive benefit from a cruciate-sparing bi-UKA. Cite this article: Bone Joint J 2021;103-B(10):1561–1570


Aims. The aim of this study was to compare any differences in the primary outcome (biphasic flexion knee moment during gait) of robotic arm-assisted bi-unicompartmental knee arthroplasty (bi-UKA) with conventional mechanically aligned total knee arthroplasty (TKA) at one year post-surgery. Methods. A total of 76 patients (34 bi-UKA and 42 TKA patients) were analyzed in a prospective, single-centre, randomized controlled trial. Flat ground shod gait analysis was performed preoperatively and one year postoperatively. Knee flexion moment was calculated from motion capture markers and force plates. The same setup determined proprioception outcomes during a joint position sense test and one-leg standing. Surgery allocation, surgeon, and secondary outcomes were analyzed for prediction of the primary outcome from a binary regression model. Results. Both interventions were shown to be effective treatment options, with no significant differences shown between interventions for the primary outcome of this study (18/35 (51.4%) biphasic TKA patients vs 20/31 (64.5%) biphasic bi-UKA patients; p = 0.558). All outcomes were compared to an age-matched, healthy cohort that outperformed both groups, indicating residual deficits exists following surgery. Logistic regression analysis of primary outcome with secondary outcomes indicated that the most significant predictor of postoperative biphasic knee moments was preoperative knee moment profile and trochlear degradation (Outerbridge) (R. 2. = 0.381; p = 0.002, p = 0.046). A separate regression of alignment against primary outcome indicated significant bi-UKA femoral and tibial axial alignment (R. 2. = 0.352; p = 0.029), and TKA femoral sagittal alignment (R. 2. = 0.252; p = 0.016). The bi-UKA group showed a significant increased ability in the proprioceptive joint position test, but no difference was found in more dynamic testing of proprioception. Conclusion. Robotic arm-assisted bi-UKA demonstrated equivalence to TKA in achieving a biphasic gait pattern after surgery for osteoarthritis of the knee. Both treatments are successful at improving gait, but both leave the patients with a functional limitation that is not present in healthy age-matched controls. Cite this article: Bone Joint J 2022;103-B(4):433–443


The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 663 - 671
1 Jun 2022
Lewis E Merghani K Robertson I Mulford J Prentice B Mathew R Van Winden P Ogden K

Aims

Platelet-rich plasma (PRP) intra-articular injections may provide a simple and minimally invasive treatment for early-stage knee osteoarthritis (OA). This has led to an increase in its adoption as a treatment for knee OA, although there is uncertainty about its efficacy and benefit. We hypothesized that patients with early-stage symptomatic knee OA who receive multiple PRP injections will have better clinical outcomes than those receiving single PRP or placebo injections.

Methods

A double-blinded, randomized placebo-controlled trial was performed with three groups receiving either placebo injections (Normal Saline), one PRP injection followed by two placebo injections, or three PRP injections. Each injection was given one week apart. Outcomes were prospectively collected prior to intervention and then at six weeks, three months, six months, and 12 months post-intervention. Primary outcome measures were Knee Injury and Osteoarthritis Outcome Score (KOOS) and EuroQol five-dimension five-level index (EQ-5D-5L). Secondary outcomes included visual analogue scale for pain and patient subjective assessment of the injections.


The Bone & Joint Journal
Vol. 102-B, Issue 5 | Pages 586 - 592
1 May 2020
Wijn SRW Rovers MM van Tienen TG Hannink G

Aims. Recent studies have suggested that corticosteroid injections into the knee may harm the joint resulting in cartilage loss and possibly accelerating the progression of osteoarthritis (OA). The aim of this study was to assess whether patients with, or at risk of developing, symptomatic osteoarthritis of the knee who receive intra-articular corticosteroid injections have an increased risk of requiring arthroplasty. Methods. We used data from the Osteoarthritis Initiative (OAI), a multicentre observational cohort study that followed 4,796 patients with, or at risk of developing, osteoarthritis of the knee on an annual basis with follow-up available up to nine years. Increased risk for symptomatic OA was defined as frequent knee symptoms (pain, aching, or stiffness) without radiological evidence of OA and two or more risk factors, while OA was defined by the presence of both femoral osteophytes and frequent symptoms in one or both knees. Missing data were imputed with multiple imputations using chained equations. Time-dependent propensity score matching was performed to match patients at the time of receving their first injection with controls. The effect of corticosteroid injections on the rate of subsequent (total and partial) knee arthroplasty was estimated using Cox proportional-hazards survival analyses. Results. After removing patients lost to follow-up, 3,822 patients remained in the study. A total of 249 (31.3%) of the 796 patients who received corticosteroid injections, and 152 (5.0%) of the 3,026 who did not, had knee arthroplasty. In the matched cohort, Cox proportional-hazards regression resulted in a hazard ratio of 1.57 (95% confidence interval (CI) 1.37 to 1.81; p < 0.001) and each injection increased the absolute risk of arthroplasty by 9.4% at nine years’ follow-up compared with those who did not receive injections. Conclusion. Corticosteroid injections seem to be associated with an increased risk of knee arthroplasty in patients with, or at risk of developing, symptomatic OA of the knee. These findings suggest that a conservative approach regarding the treatment of these patients with corticosteroid injections should be recommended. Cite this article: Bone Joint J 2020;102-B(5):586–592


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 1025 - 1032
1 Aug 2020
Hampton M Mansoor J Getty J Sutton PM

Aims. Total knee arthroplasty is an established treatment for knee osteoarthritis with excellent long-term results, but there remains controversy about the role of uncemented prostheses. We present the long-term results of a randomized trial comparing an uncemented tantalum metal tibial component with a conventional cemented component of the same implant design. Methods. Patients under the age of 70 years with symptomatic osteoarthritis of the knee were randomized to receive either an uncemented tantalum metal tibial monoblock component or a standard cemented modular component. The mean age at time of recruitment to the study was 63 years (50 to 70), 46 (51.1%) knees were in male patients, and the mean body mass index was 30.4 kg/m. 2. (21 to 36). The same cruciate retaining total knee system was used in both groups. All patients received an uncemented femoral component and no patients had their patella resurfaced. Patient outcomes were assessed preoperatively and postoperatively using the modified Oxford Knee Score, Knee Society Score, and 12-Item Short-Form Health Survey questionnaire (SF-12) score. Radiographs were analyzed using the American Knee Society Radiograph Evaluation score. Operative complications, reoperations, or revision surgery were recorded. A total of 90 knees were randomized and at last review 77 knees were assessed. In all, 11 patients had died and two were lost to follow-up. Results. At final review all patients were between 11 and 15 years following surgery. In total, 41 of the knees were cemented and 36 uncemented. There were no revisions in the cemented group and one revision in the uncemented group for fracture. The uncemented group reported better outcomes with both statistically and clinically significant (p = 0.001) improvements in knee-specific Oxford and Knee Society scores compared with the cemented group. The global SF-12 scores demonstrated no statistical difference (p = 0.812). Uncemented knees had better radiological analysis compared with the cemented group (p < 0.001). Conclusion. Use of an uncemented trabecular metal tibial implant can afford better long-term clinical outcomes when compared to cemented tibial components of a matched design. However, both have excellent survivorship up to 15 years after implantation. Cite this article: Bone Joint J 2020;102-B(8):1025–1032


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 113 - 122
1 Jan 2021
Kayani B Tahmassebi J Ayuob A Konan S Oussedik S Haddad FS

Aims. The primary aim of this study was to compare the postoperative systemic inflammatory response in conventional jig-based total knee arthroplasty (conventional TKA) versus robotic-arm assisted total knee arthroplasty (robotic TKA). Secondary aims were to compare the macroscopic soft tissue injury, femoral and tibial bone trauma, localized thermal response, and the accuracy of component positioning between the two treatment groups. Methods. This prospective randomized controlled trial included 30 patients with osteoarthritis of the knee undergoing conventional TKA versus robotic TKA. Predefined serum markers of inflammation and localized knee temperature were collected preoperatively and postoperatively at six hours, day 1, day 2, day 7, and day 28 following TKA. Blinded observers used the Macroscopic Soft Tissue Injury (MASTI) classification system to grade intraoperative periarticular soft tissue injury and bone trauma. Plain radiographs were used to assess the accuracy of achieving the planned postioning of the components in both groups. Results. Patients undergoing conventional TKA and robotic TKA had comparable changes in the postoperative systemic inflammatory and localized thermal response at six hours, day 1, day 2, and day 28 after surgery. Robotic TKA had significantly reduced levels of interleukin-6 (p < 0.001), tumour necrosis factor-α (p = 0.021), ESR (p = 0.001), CRP (p = 0.004), lactate dehydrogenase (p = 0.007), and creatine kinase (p = 0.004) at day 7 after surgery compared with conventional TKA. Robotic TKA was associated with significantly improved preservation of the periarticular soft tissue envelope (p < 0.001), and reduced femoral (p = 0.012) and tibial (p = 0.023) bone trauma compared with conventional TKA. Robotic TKA significantly improved the accuracy of achieving the planned limb alignment (p < 0.001), femoral component positioning (p < 0.001), and tibial component positioning (p < 0.001) compared with conventional TKA. Conclusion. Robotic TKA was associated with a transient reduction in the early (day 7) postoperative inflammatory response but there was no difference in the immediate (< 48 hours) or late (day 28) postoperative systemic inflammatory response compared with conventional TKA. Robotic TKA was associated with decreased iatrogenic periarticular soft tissue injury, reduced femoral and tibial bone trauma, and improved accuracy of component positioning compared with conventional TKA. Cite this article: Bone Joint J 2021;103-B(1):113–122


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 7 | Pages 1001 - 1005
1 Sep 2000
Draper ERC Cable JM Sanchez-Ballester J Hunt N Robinson JR Strachan RK

The use of a valgus brace can effectively relieve the symptoms of unicompartmental osteoarthritis of the knee. This study provides an objective measurement of function by analysis of gait symmetry. This was measured in 30 patients on four separate occasions: immediately before and after initial fitting and then again at three months with the brace on and off. All patients reported immediate symptomatic improvement with less pain on walking. After fitting the brace, symmetry indices of stance and the swing phase of gait showed a consistent and immediate improvement at 0 and 3 months, respectively, of 3.92% (p = 0.030) and 3.40% (p = 0.025) in the stance phase and 11.78% (p = 0.020) and 9.58% (p = 0.005) in the swing phase. This was confirmed by a significant improvement at three months in the mean Hospital for Special Surgery (HSS) knee score from 69.9 to 82.0 (p < 0.001). Thus, wearing a valgus brace gives a significant and immediate improvement in the function of patients with unicompartmental osteoarthritis of the knee, as measured by analysis of gait symmetry