Advertisement for orthosearch.org.uk
Results 1 - 7 of 7
Results per page:

Aims. The primary aim of this study was to report the radiological outcomes of patients with a dorsally displaced distal radius fracture who were randomized to a moulded cast or surgical fixation with wires following manipulation and closed reduction of their fracture. The secondary aim was to correlate radiological outcomes with patient-reported outcome measures (PROMs) in the year following injury. Methods. Participants were recruited as part of DRAFFT2, a UK multicentre clinical trial. Participants were aged 16 years or over with a dorsally displaced distal radius fracture, and were eligible for the trial if they needed a manipulation of their fracture, as recommended by their treating surgeon. Participants were randomly allocated on a 1:1 ratio to moulded cast or Kirschner wires after manipulation of the fracture in the operating theatre. Standard posteroanterior and lateral radiographs were performed in the radiology department of participating centres at the time of the patient’s initial assessment in the emergency department and six weeks postoperatively. Intraoperative fluoroscopic images taken at the time of fracture reduction were also assessed. Results. Patients treated with surgical fixation with wires had less dorsal angulation of the radius versus those treated in a moulded cast at six weeks after manipulation of the fracture; the mean difference of -4.13° was statistically significant (95% confidence interval 5.82 to -2.45). There was no evidence of a difference in radial shortening. However, there was no correlation between these radiological measurements and PROMs at any timepoint in the 12 months post-injury. Conclusion. For patients with a dorsally displaced distal radius fracture treated with a closed manipulation, surgical fixation with wires leads to less dorsal angulation on radiographs at six weeks compared with patients treated in a moulded plaster cast alone. However, the difference in dorsal angulation was small and did not correlate with patient-reported pain and function. Cite this article: Bone Jt Open 2024;5(2):132–138


The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1225 - 1233
1 Nov 2022
Png ME Petrou S Achten J Ooms A Lamb SE Hedley H Dias J Costa ML

Aims

The aim of this study was to compare the cost-effectiveness of surgical fixation with Kirschner (K-)wire ersus moulded casting after manipulation of a fracture of the distal radius in an operating theatre setting.

Methods

An economic evaluation was conducted based on data collected from the Distal Radius Acute Fracture Fixation Trial 2 (DRAFFT2) multicentre randomized controlled trial in the UK. Resource use was collected at three, six, and 12 months post-randomization using trial case report forms and participant-completed questionnaires. Cost-effectiveness was reported in terms of incremental cost per quality-adjusted life year (QALY) gained from an NHS and personal social services perspective. Sensitivity analyses were conducted to examine the robustness of cost-effectiveness estimates, and decision uncertainty was handled using confidence ellipses and cost-effectiveness acceptability curves.


The Bone & Joint Journal
Vol. 104-B, Issue 8 | Pages 946 - 952
1 Aug 2022
Wu F Zhang Y Liu B

Aims

This study aims to report the outcomes in the treatment of unstable proximal third scaphoid nonunions with arthroscopic curettage, non-vascularized bone grafting, and percutaneous fixation.

Methods

This was a retrospective analysis of 20 patients. All cases were delayed presentations (n = 15) or failed nonoperatively managed scaphoid fractures (n = 5). Surgery was performed at a mean duration of 27 months (7 to 120) following injury with arthroscopic debridement and arthroscopic iliac crest autograft. Fracture fixation was performed percutaneously with Kirschner (K)-wires in 12 wrists, a headless screw in six, and a combination of a headless screw and single K-wire in two. Clinical outcomes were assessed using grip strength, patient-reported outcome measures, and wrist range of motion (ROM) measurements.


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 696 - 704
1 Jul 2024
Barvelink B Reijman M Smidt S Miranda Afonso P Verhaar JAN Colaris JW

Aims

It is not clear which type of casting provides the best initial treatment in adults with a distal radial fracture. Given that between 32% and 64% of adequately reduced fractures redisplace during immobilization in a cast, preventing redisplacement and a disabling malunion or secondary surgery is an aim of treatment. In this study, we investigated whether circumferential casting leads to fewer fracture redisplacements and better one-year outcomes compared to plaster splinting.

Methods

In a pragmatic, open-label, multicentre, two-period cluster-randomized superiority trial, we compared these two types of casting. Recruitment took place in ten hospitals. Eligible patients aged ≥ 18 years with a displaced distal radial fracture, which was acceptably aligned after closed reduction, were included. The primary outcome measure was the rate of redisplacement within five weeks of immobilization. Secondary outcomes were the rate of complaints relating to the cast, clinical outcomes at three months, patient-reported outcome measures (PROMs) (using the numerical rating scale (NRS), the abbreviated version of the Disabilities of the Arm, Shoulder and Hand (QuickDASH), and Patient-Rated Wrist/Hand Evaluation (PRWHE) scores), and adverse events such as the development of compartment syndrome during one year of follow-up. We used multivariable mixed-effects logistic regression for the analysis of the primary outcome measure.


Bone & Joint Open
Vol. 2, Issue 5 | Pages 338 - 343
21 May 2021
Harvey J Varghese BJ Hahn DM

Aims

Displaced distal radius fractures were investigated at a level 1 major trauma centre during the COVID-19 2020 lockdown due to the implementation of temporary changes in practice. The primary aim was to establish if follow-up at one week in place of the 72-hour British Orthopaedic Association Standards for Trauma & Orthopaedics (BOAST) guidance was safe following manipulation under anaesthetic. A parallel adaptation during lockdown was the non-expectation of Bier’s block. The secondary aim was to compare clinical outcomes with respect to block type.

Methods

Overall, 90 patients were assessed in a cross-sectional cohort study using a mixed, retrospective-prospective approach. Consecutive sampling of 30 patients pre-lockdown (P1), 30 during lockdown (P2), and 30 during post-lockdown (P3) was applied. Type of block, operative status, follow-up, and complications were extracted. Primary endpoints were early complications (≤ one week). Secondary endpoints were later complications including malunion, delayed union or osteotomy.


Bone & Joint Research
Vol. 9, Issue 7 | Pages 429 - 439
1 Jul 2020
Tahir M Chaudhry EA Zaffar Z Anwar K Mamoon MAH Ahmad M Jamali AR Mehboob G

Aims

We hypothesized that the wide-awake local anaesthesia with no tourniquet (WALANT) technique is cost-effective, easy to use, safe, and reproducible, with a low learning curve towards mastery, having a high patient satisfaction rate. Furthermore, WALANT would be a suitable alternative for the austere and developing nation environments where lack of funds and resources are a common issue.

Methods

This was a randomized control trial of 169 patients who required surgery for closed isolated distal radius fractures. The study was performed between March 2016 and April 2019 at a public sector level 1 trauma centre. General anaesthesia was used in 56 patients, Bier’s block in 58 patients, and WALANT in 55 patients. Data were collected on pre-, peri-, and postoperative parameters, clinical outcome, hospital costs, and patient satisfaction. One-way analysis of variance (ANOVA) was used with a p-value of 0.05 being significant.


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1514 - 1520
1 Nov 2013
D’Agostino P Barbier O

The osteoinductive properties of demineralised bone matrix have been demonstrated in animal studies. However, its therapeutic efficacy has yet to be proven in humans. The clinical properties of AlloMatrix, an injectable calcium-based demineralised bone matrix allograft, were studied in a prospective randomised study of 50 patients with an isolated unstable distal radial fracture treated by reduction and Kirschner (K-) wire fixation. A total of 24 patients were randomised to the graft group (13 men and 11 women, mean age 42.3 years (20 to 62)) and 26 to the no graft group (8 men and 18 women, mean age 45.0 years (17 to 69)). At one, three, six and nine weeks, and six and 12 months post-operatively, patients underwent radiological evaluation, assessments for range of movement, grip and pinch strength, and also completed the Disabilities of Arm, Shoulder and Hand questionnaire. At one and six weeks and one year post-operatively, bone mineral density evaluations of both wrists were performed. No significant difference in wrist function and speed of recovery, rate of union, complications or bone mineral density was found between the two groups. The operating time was significantly higher in the graft group (p = 0.004). Radiologically, the reduction parameters remained similar in the two groups and all AlloMatrix extraosseous leakages disappeared after nine weeks. This prospective randomised controlled trial did not demonstrate a beneficial effect of AlloMatrix demineralised bone matrix in the treatment of this category of distal radial fractures treated by K-wire fixation. Cite this article: Bone Joint J 2013;95-B:1514–20