Advertisement for orthosearch.org.uk
Results 1 - 12 of 12
Results per page:
The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 199 - 205
1 Feb 2013
Robinson PM Wilson J Dalal S Parker RA Norburn P Roy BR

This study reports the clinical and sonographic outcome of arthroscopic rotator cuff repair in patients aged ≥ 70 years and aimed to determine factors associated with re-tear. A total of 69 consecutive repairs were performed in 68 patients with a mean age of 77 years (70 to 86). Constant-Murley scores were collected pre-operatively and at one year post-operatively. The integrity of the repair was assessed using ultrasound. Re-tear was detected in 20 of 62 patients (32%) assessed with ultrasound. Age at operation was significantly associated with re-tear free survival (p = 0.016). The mean pre-operative Constant score was 23 (sd 14), which increased to 58 (sd 20) at one year post-operatively (paired t-test, p < 0.001). Male gender was significantly associated with a higher score at one year (p = 0.019).

We conclude that arthroscopic rotator cuff repair in patients aged ≥ 70 years is a successful procedure. The gender and age of the patient are important factors to consider when planning management.

Cite this article: Bone Joint J 2013;95-B:199–205.


Bone & Joint Research
Vol. 13, Issue 4 | Pages 169 - 183
15 Apr 2024
Gil-Melgosa L Llombart-Blanco R Extramiana L Lacave I Abizanda G Miranda E Agirre X Prósper F Pineda-Lucena A Pons-Villanueva J Pérez-Ruiz A

Aims. Rotator cuff (RC) injuries are characterized by tendon rupture, muscle atrophy, retraction, and fatty infiltration, which increase injury severity and jeopardize adequate tendon repair. Epigenetic drugs, such as histone deacetylase inhibitors (HDACis), possess the capacity to redefine the molecular signature of cells, and they may have the potential to inhibit the transformation of the fibro-adipogenic progenitors (FAPs) within the skeletal muscle into adipocyte-like cells, concurrently enhancing the myogenic potential of the satellite cells. Methods. HDACis were added to FAPs and satellite cell cultures isolated from mice. The HDACi vorinostat was additionally administered into a RC injury animal model. Histological analysis was carried out on the isolated supra- and infraspinatus muscles to assess vorinostat anti-muscle degeneration potential. Results. Vorinostat, a HDACi compound, blocked the adipogenic transformation of muscle-associated FAPs in culture, promoting myogenic progression of the satellite cells. Furthermore, it protected muscle from degeneration after acute RC in mice in the earlier muscle degenerative stage after tenotomy. Conclusion. The HDACi vorinostat may be a candidate to prevent early muscular degeneration after RC injury. Cite this article: Bone Joint Res 2024;13(4):169–183


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 348 - 351
1 Mar 2005
Kreuz PC Remiger A Lahm A Herget G Gächter A

We treated surgically 16 shoulders with an isolated traumatic rupture of the subscapularis tendon over a six-year period. Nine patients had a total and seven a partial tear of the subscapularis tendon. Repair was undertaken through a small deltopectoral groove approach. The mean Constant score improved in total tears from 38.7 to 89.3 points (p = 0.003) and in partial tears from 50.7 to 87.9 points (p = 0.008). The total tears were significantly more improved by surgery than the partial tears (p = 0.001). The delay between trauma and surgery was inversely proportional to the improvement in the Constant score suggesting that early diagnosis and surgical repair improves outcome


Bone & Joint Research
Vol. 10, Issue 5 | Pages 298 - 306
1 May 2021
Dolkart O Kazum E Rosenthal Y Sher O Morag G Yakobson E Chechik O Maman E

Aims

Rotator cuff (RC) tears are common musculoskeletal injuries which often require surgical intervention. Noninvasive pulsed electromagnetic field (PEMF) devices have been approved for treatment of long-bone fracture nonunions and as an adjunct to lumbar and cervical spine fusion surgery. This study aimed to assess the effect of continuous PEMF on postoperative RC healing in a rat RC repair model.

Methods

A total of 30 Wistar rats underwent acute bilateral supraspinatus tear and repair. A miniaturized electromagnetic device (MED) was implanted at the right shoulder and generated focused PEMF therapy. The animals’ left shoulders served as controls. Biomechanical, histological, and bone properties were assessed at three and six weeks.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 83 - 91
1 Jan 2010
Moosmayer S Lund G Seljom U Svege I Hennig T Tariq R Smith H

In order to compare the outcome from surgical repair and physiotherapy, 103 patients with symptomatic small and medium-sized tears of the rotator cuff were randomly allocated to one of the two approaches. The primary outcome measure was the Constant score, and secondary outcome measures included the self-report section of the American Shoulder and Elbow Surgeons score, the Short Form 36 Health Survey and subscores for shoulder movement, pain, strength and patient satisfaction. Scores were taken at baseline and after six and 12 months by a blinded assessor. Nine patients (18%) with insufficient benefit from physiotherapy after at least 15 treatment sessions underwent secondary surgical treatment.

Analysis of between-group differences showed better results for the surgery group on the Constant scale (difference 13.0 points, p − 0.002), on the American Shoulder and Elbow surgeons scale (difference 16.1 points, p < 0.0005), for pain-free abduction (difference 28.8°, p = 0.003) and for reduction in pain (difference on a visual analogue scale −1.7 cm, p < 0.0005).


Bone & Joint Research
Vol. 1, Issue 9 | Pages 210 - 217
1 Sep 2012
Walton JR Murrell GAC

Objectives

The aim of this study was to determine whether there is any significant difference in temporal measurements of pain, function and rates of re-tear for arthroscopic rotator cuff repair (RCR) patients compared with those patients undergoing open RCR.

Methods

This study compared questionnaire- and clinical examination-based outcomes over two years or longer for two series of patients who met the inclusion criteria: 200 open RCR and 200 arthroscopic RCR patients. All surgery was performed by a single surgeon.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 210 - 216
1 Feb 2011
Young A Walch G Boileau P Favard L Gohlke F Loew M Molé D

We report the long-term clinical and radiological outcomes of the Aequalis total shoulder replacement with a cemented all-polyethylene flat-back keeled glenoid component implanted for primary osteoarthritis between 1991 and 2003 in nine European centres. A total of 226 shoulders in 210 patients were retrospectively reviewed at a mean of 122.7 months (61 to 219) or at revision. Clinical outcome was assessed using the Constant score, patient satisfaction score and range of movement. Kaplan-Meier survivorship analysis was performed with glenoid revision for loosening and radiological glenoid loosening (sd) as endpoints. The Constant score was found to improve from a mean of 26.8 (sd 10.3) pre-operatively to 57.6 (sd 20.0) post-operatively (p < 0.001). Active forward flexion improved from a mean of 85.3° (sd 27.4) pre-operatively to 125° (sd 37.3) postoperatively (p < 0.001). External rotation improved from a mean of 7° (sd 6.5) pre-operatively to 30.3° (sd 21.8°) post-operatively (p < 0.001). Survivorship with revision of the glenoid component as the endpoint was 99.1% at five years, 94.5% at ten years and 79.4% at 15 years. Survivorship with radiological loosening as the endpoint was 99.1% at five years, 80.3% at ten years and 33.6% at 15 years.

Younger patient age and the curettage technique for glenoid preparation correlated with loosening. The rate of glenoid revision and radiological loosening increased with duration of follow-up, but not until a follow-up of five years. Therefore, we recommend that future studies reporting radiological outcomes of new glenoid designs should report follow-up of at least five to ten years.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 8 | Pages 1059 - 1065
1 Aug 2008
Elhassan B Ozbaydar M Massimini D Diller D Higgins L Warner JJP

Transfer of pectoralis major has evolved as the most favoured option for the management of the difficult problem of irreparable tears of subscapularis. We describe our experience with this technique in 30 patients divided into three groups. Group I comprised 11 patients with a failed procedure for instability of the shoulder, group II included eight with a failed shoulder replacement and group III, 11 with a massive tear of the rotator cuff. All underwent transfer of the sternal head of pectoralis major to restore the function of subscapularis.

At the latest follow-up pain had improved in seven of the 11 patients in groups I and III, but in only one of eight in group II. The subjective shoulder score improved in seven patients in group I, in one in group II and in six in group III. The mean Constant score improved from 40.9 points (28 to 50) in group I, 32.9 (17 to 47) in group II and 28.7 (20 to 42) in group III pre-operatively to 60.8 (28 to 89), 41.9 (24 to 73) and 52.3 (24 to 78), respectively.

Failure of the tendon transfer was highest in group II and was associated with pre-operative anterior subluxation of the humeral head. We conclude that in patients with irreparable rupture of subscapularis after shoulder replacement there is a high risk of failure of transfer of p?ctoralis major, particularly if there is pre-operative anterior subluxation of the humeral head.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 12 | Pages 1620 - 1626
1 Dec 2007
Toma CD Machacek P Bitzan P Assadian O Trieb K Wanivenhaus A

We retrospectively compared wrist arthrodesis using the Mannerfelt technique in 19 or an AO-plate in 23 patients with long-standing rheumatoid arthritis. The mean follow-up was for 76 months.

Compared with the Mannerfelt fusion group, patients in the AO-plate group reported greater satisfaction with their wrist function (74% vs 37%, p = 0.015). Complications were reported in six wrists in the AO-plate group and two wrists in the Mannerfelt fusion group (p = 0.258). At final follow-up, 95% of patients (41) reported either no pain or only mild pain. There was improvement in flexion of the finger joints in both groups but no significant improvement in the extension lag in either group.

Both methods relieve pain and improve function. Overall, the activities of daily living scores and the patients’ subjective assessment of outcome tended to be higher in the AO-plate group than in the Mannerfelt fusion group, although the difference was not statistically significant. Similarly, although more postoperative complications occurred in the AO-plate group, the difference between the two groups was not statistically significant.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 4 | Pages 489 - 495
1 Apr 2006
Matthews TJW Hand GC Rees JL Athanasou NA Carr AJ

We have studied cellular and vascular changes in different stages of full thickness tears of the rotator cuff. We examined biopsies from the supraspinatus tendon in 40 patients with chronic rotator cuff tears who were undergoing surgery and compared them with biopsies from four uninjured subscapularis tendons. Morphological and immunocytochemical methods using monoclonal antibodies directed against leucocytes, macrophages, mast cells, proliferative and vascular markers were used.

Histological changes indicative of repair and inflammation were most evident in small sized rotator cuff tears with increased fibroblast cellularity and intimal hyperplasia, together with increased expression of leucocyte and vascular markers. These reparative and inflammatory changes diminished as the size of the rotator cuff tear increased. Marked oedema and degeneration was seen in large and massive tears, which more often showed chondroid metaplasia and amyloid deposition. There was no association between the age of the patient and the duration of symptoms. In contrast, large and massive tears showed no increase in the number of inflammatory cells and blood vessels.

Small sized rotator cuff tears retained the greatest potential to heal, showing increased fibroblast cellularity, blood vessel proliferation and the presence of a significant inflammatory component. Tissue from large and massive tears is of such a degenerative nature that it may be a significant cause of re-rupture after surgical repair and could make healing improbable in this group.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 1 - 9
1 Jan 2012
Robinson CM Seah KTM Chee YH Hindle P Murray IR

Frozen shoulder is commonly encountered in general orthopaedic practice. It may arise spontaneously without an obvious predisposing cause, or be associated with a variety of local or systemic disorders. Diagnosis is based upon the recognition of the characteristic features of the pain, and selective limitation of passive external rotation. The macroscopic and histological features of the capsular contracture are well-defined, but the underlying pathological processes remain poorly understood. It may cause protracted disability, and imposes a considerable burden on health service resources. Most patients are still managed by physiotherapy in primary care, and only the more refractory cases are referred for specialist intervention. Targeted therapy is not possible and treatment remains predominantly symptomatic. However, over the last ten years, more active interventions that may shorten the clinical course, such as capsular distension arthrography and arthroscopic capsular release, have become more popular.

This review describes the clinical and pathological features of frozen shoulder. We also outline the current treatment options, review the published results and present our own treatment algorithm.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 11 | Pages 1516 - 1519
1 Nov 2005
Togawa S Yamami N Nakayama H Mano Y Ikegami K Ozeki S

The Mangled Extremity Severity Score (MESS) may be used to decide whether to perform amputation in patients with injuries involving a limb. A score of 7 points or higher indicates the need for amputation. We have treated three patients with a MESS of 7 points or higher, in two of which the injured limb was salvaged. This scoring system was originally devised to assess injuries to the lower limb. However, a MESS of 7 points as a justification for amputation does not appear appropriate when assessing injuries to the major vessels in the upper limb.