Advertisement for orthosearch.org.uk
Results 1 - 20 of 110
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1148 - 1155
1 Oct 2022
Watts AC Hamoodi Z McDaid C Hewitt C

Aims. Arthroplasties of the elbow, including total elbow arthroplasty, radial head arthroplasty, distal humeral hemiarthroplasty, and radiocapitellar arthroplasty, are rarely undertaken. This scoping review aims to outline the current research in this area to inform the development of future research. Methods. A scoping review was undertaken adhering to the Joanna Briggs Institute guidelines using Medline, Embase, CENTRAL, and trial registries, limited to studies published between 1 January 1990 and 7 February 2021. Endnote software was used for screening and selection, and included randomized trials, non-randomized controlled trials, prospective and retrospective cohort studies, case-control studies, analytical cross-sectional studies, and case series of ten or more patients reporting the clinical outcomes of elbow arthroplasty. The results are presented as the number of types of studies, sample size, length of follow-up, clinical outcome domains and instruments used, sources of funding, and a narrative review. Results. A total of 362 studies met the inclusion criteria. Most were of total elbow arthroplasty (246; 68%), followed by radial head arthroplasty (100; 28%), distal humeral hemiarthroplasty (11; 3%), and radiocapitellar arthroplasty (5; 1%). Most were retrospective (326; 90%) and observational (315; 87%). The median sample size for all types of implant across all studies was 36 (interquartile range (IQR) 21 to 75). The median length of follow-up for all studies was 56 months (IQR 36 to 81). A total of 583 unique outcome descriptors were used and were categorized into 18 domains. A total of 105 instruments were used to measure 39 outcomes. Conclusion. We found that most of the literature dealing with elbow arthroplasty consists of retrospective observational studies with small sample sizes and short follow-up. Many outcomes have been used with many different instruments for their measurement, indicating a need to define a core set of outcomes and instruments for future research in this area. Cite this article: Bone Joint J 2022;104-B(10):1148–1155


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1272 - 1279
1 Oct 2019
Nowak LL Hall J McKee MD Schemitsch EH

Aims. To compare complication-related reoperation rates following primary arthroplasty for proximal humerus fractures (PHFs) versus secondary arthroplasty for failed open reduction and internal fixation (ORIF). Patients and Methods. We identified patients aged 50 years and over, who sustained a PHF between 2004 and 2015, from linkable datasets. We used intervention codes to identify patients treated with initial ORIF or arthroplasty, and those treated with ORIF who returned for revision arthroplasty within two years. We used multilevel logistic regression to compare reoperations between groups. Results. We identified 1624 patients who underwent initial arthroplasty for PHF, and 98 patients who underwent secondary arthroplasty following failed ORIF. In total, 72 patients (4.4%) in the primary arthroplasty group had a reoperation within two years following arthroplasty, compared with 19 patients (19.4%) in the revision arthroplasty group. This difference was significantly different (p < 0.001) after covariable adjustment. Conclusion. The number of reoperations following arthroplasty for failed ORIF of PHF is significantly higher compared with primary arthroplasty. This suggests that primary arthroplasty may be a better choice for patients whose prognostic factors suggest a high reoperation rate following ORIF. Prospective clinical studies are required to confirm these findings. Cite this article: Bone Joint J 2019;101-B:1272–1279


The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 482 - 491
1 May 2024
Davies A Sabharwal S Liddle AD Zamora Talaya MB Rangan A Reilly P

Aims

Metal and ceramic humeral head bearing surfaces are available choices in anatomical shoulder arthroplasties. Wear studies have shown superior performance of ceramic heads, however comparison of clinical outcomes according to bearing surface in total shoulder arthroplasty (TSA) and hemiarthroplasty (HA) is limited. This study aimed to compare the rates of revision and reoperation following metal and ceramic humeral head TSA and HA using data from the National Joint Registry (NJR), which collects data from England, Wales, Northern Ireland, Isle of Man and the States of Guernsey.

Methods

NJR shoulder arthroplasty records were linked to Hospital Episode Statistics and the National Mortality Register. TSA and HA performed for osteoarthritis (OA) in patients with an intact rotator cuff were included. Metal and ceramic humeral head prostheses were matched within separate TSA and HA groups using propensity scores based on 12 and 11 characteristics, respectively. The primary outcome was time to first revision and the secondary outcome was non-revision reoperation.


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1609 - 1617
1 Dec 2018
Malhas AM Granville-Chapman J Robinson PM Brookes-Fazakerley S Walton M Monga P Bale S Trail I

Aims. We present our experience of using a metal-backed prosthesis and autologous bone graft to treat gross glenoid bone deficiency. Patients and Methods. A prospective cohort study of the first 45 shoulder arthroplasties using the SMR Axioma Trabecular Titanium (TT) metal-backed glenoid with autologous bone graft. Between May 2013 and December 2014, 45 shoulder arthroplasties were carried out in 44 patients with a mean age of 64 years (35 to 89). The indications were 23 complex primary arthroplasties, 12 to revise a hemiarthroplasty or resurfacing, five for aseptic loosening of the glenoid, and five for infection. Results. Of the 45 patients, 16 had anatomical shoulder arthroplasties (ASA) and 29 had reverse shoulder arthroplasties (RSA). Postoperatively, 43/45 patients had a CT scan. In 41 of 43 patients (95%), the glenoid peg achieved > 50% integration. In 40 of 43 cases (93%), the graft was fully or partially integrated. There were seven revisions (16%) but only four (9%) required a change of baseplate. Four (25%) of the 16 ASAs were revised for instability or cuff failure. At two-year radiological follow-up, five of the 41 cases (11%) showed some evidence of lucent lines. Conclusion. The use of a metal baseplate with a trabecular titanium surface in conjunction with autologous bone graft is a reliable method of addressing glenoid bone defects in primary and revision RSA setting in the short term. ASAs have a higher rate of complications with this technique


The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1362 - 1369
1 Nov 2019
Giannicola G Calella P Bigazzi P Mantovani A Spinello P Cinotti G

Aims. The aim of this study was to analyze the results of two radiocapitellar prostheses in a large case series followed prospectively, with medium-term follow-up. Patients and Methods. A total of 31 patients with a mean age of 54 years (27 to 73) were analyzed; nine had primary osteoarthritis (OA) and 17 had post-traumatic OA, three had capitellar osteonecrosis, and two had a fracture. Overall, 17 Lateral Resurfacing Elbow (LRE) and 14 Uni-Elbow Radio-Capitellum Implant (UNI-E) arthroplasties were performed. Pre- and postoperative assessment involved the Mayo Elbow Performance Score (MEPS), the Quick Disabilities of the Arm, Shoulder and Hand (Q-DASH) score, and the modified American Shoulder Elbow Surgeons (m-ASES) score. Results. The mean follow-up was 6.8 years (3.8 to 11.5). The mean MEPS, m-ASES, and Q-DASH scores improved significantly by 50 (p < 0.001), 55 (p < 0.001), and 54 points (p < 0.001), respectively, with no differences being detected between the implants. Preoperative pronation and supination were worse in patients in whom the UNI-E was used. Two patients with the UNI-E implant had asymptomatic evidence of gross loosening. Conclusion. Radiocapitellar arthroplasty yielded a significant improvement in elbow function at a mean follow-up of 6.8 years, with a high implant survival rate when the LRE was used in patients with primary or post-traumatic OA, without radial head deformity, and when the UNI-E was used in patients in whom radial head excision was indicated. Cite this article: Bone Joint J 2019;101-B:1362–1369


The Bone & Joint Journal
Vol. 100-B, Issue 3 | Pages 338 - 345
1 Mar 2018
Watkins CEL Elson DW Harrison JWK Pooley J

Aim. The aim of this study was to report the long-term outcome and implant survival of the lateral resurfacing elbow (LRE) arthroplasty in the treatment of elbow arthritis. Patients and Methods. We reviewed a consecutive series of 27 patients (30 elbows) who underwent LRE arthroplasty between December 2005 and January 2008. There were 15 women and 12 men, with a mean age of 61 years (25 to 82). The diagnosis was primary hypotrophic osteoarthritis (OA) in 12 patients (14 elbows), post-traumatic osteoarthritis (PTOA) in five (five elbows) and rheumatoid arthritis (RA) in ten patients (11 elbows). The mean clinical outcome scores including the Mayo Elbow Performance Score (MEPS), the American Shoulder and Elbow Surgeons elbow score (ASES-e), the mean range of movement and the radiological outcome were recorded at three, six and 12 months and at a mean final follow-up of 8.3 years (7.3 to 9.4). A one sample t-test comparing pre and postoperative values, and survival analysis using the Kaplan–Meier method were undertaken. Results. A statistically significantly increased outcome score was noted for the whole group at each time interval. This was also significantly increased at each time in each of the subgroups (OA, RA, and PTOA). Implant survivorship was 100%. Conclusion. We found that the LRE arthroplasty, which was initially developed for younger patients with osteoarthritis, is an effective form of surgical treatment for a wider range of patients with more severe degenerative changes, irrespective of their cause. It is therefore a satisfactory alternative to total elbow arthroplasty (TEA) and has lower rates of complications in the subgroups of patients we have studied. It does not require activities to be restricted to the same extent as following TEA. Based on this experience, we now recommend LRE arthroplasty rather than TEA as the primary form of implant for the treatment of patients with OA of the elbow. Cite this article: Bone Joint J 2018;100-B:338–45


The Bone & Joint Journal
Vol. 100-B, Issue 6 | Pages 767 - 771
1 Jun 2018
Robinson PM MacInnes SJ Stanley D Ali AA

Aim. The primary aim of this retrospective study was to identify the incidence of heterotopic ossification (HO) following elective and trauma elbow arthroplasty. The secondary aim was to determine clinical outcomes with respect to the formation of heterotopic ossification. Patients and Methods. A total of 55 total elbow arthroplasties (TEAs) (52 patients) performed between June 2007 and December 2015 were eligible for inclusion in the study (29 TEAs for primary elective arthroplasty and 26 TEAs for trauma). At review, 15 patients (17 total elbow arthroplasties) had died from unrelated causes. There were 14 men and 38 women with a mean age of 70 years (42 to 90). The median clinical follow-up was 3.6 years (1.2 to 6) and the median radiological follow-up was 3.1 years (0.5 to 7.5). Results. The overall incidence of HO was 84% (46/55). This was higher in the trauma group (96%, 25/26) compared with the elective arthroplasty group (72%, 21/29) (p = 0.027, Fisher’s exact test). Patients in the trauma group had HO of higher Brooker class. The presence of HO did not significantly affect elbow range of movement within the trauma or elective groups (elective arthroplasty, Mann–Whitney U test, p = 0.070; trauma arthroplasty, p = 0.370, Mann–Whitney U test). Conclusion. HO after total elbow arthroplasty is seen more commonly than previously reported. We have reported a significantly higher rate of HO in TEAs performed for trauma than those performed electively. Cite this article: Bone Joint J 2018;100-B:767–71


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 666 - 673
1 May 2017
Werthel J Lonjon G Jo S Cofield R Sperling JW Elhassan BT

Aims. In the initial development of total shoulder arthroplasty (TSA), the humeral component was usually fixed with cement. Cementless components were subsequently introduced. The aim of this study was to compare the long-term outcome of cemented and cementless humeral components in arthroplasty of the shoulder. Patients and Methods. All patients who underwent primary arthroplasty of the shoulder at our institution between 1970 and 2012 were included in the study. There were 4636 patients with 1167 cemented humeral components and 3469 cementless components. Patients with the two types of fixation were matched for nine different covariates using a propensity score analysis. A total of 551 well-balanced pairs of patients with cemented and cementless components were available after matching for comparison of the outcomes. The clinical outcomes which were analysed included loosening of the humeral component determined at revision surgery, periprosthetic fractures, post-operative infection and operating time. Results. The overall five-, ten-, 15- and 20-year rates of survival were 98.9%, 97.2%, 95.5%, and 94.4%, respectively. Survival without loosening at 20 years was 98% for cemented components and 92.4% for cementless components. After propensity score matching including fixation as determined by the design of the component, humeral loosening was also found to be significantly higher in the cementless group. Survival without humeral loosening at 20 years was 98.7% for cemented components and 91.0% for cementless components. There was no significant difference in the risk of intra- or post-operative fracture. The rate of survival without deep infection and the mean operating time were significantly higher in the cemented group. Conclusion. Both types of fixation give rates of long-term survival of > 90%. Cemented components have better rates of survival without loosening but this should be weighed against increased operating time and the risk of bony destruction of the proximal humerus at the time of revision of a cemented humeral component. Cite this article: Bone Joint J 2017;99-B:666–73


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1681 - 1686
1 Dec 2013
Peach CA Nicoletti S Lawrence TM Stanley D

We report our experience of staged revision surgery for the treatment of infected total elbow arthroplasty (TEA). Between 1998 and 2010 a consecutive series of 33 patients (34 TEAs) underwent a first-stage procedure with the intention to proceed to second-stage procedure when the infection had been controlled. A single first-stage procedure with removal of the components and cement was undertaken for 29 TEAs (85%), followed by the insertion of antibiotic-impregnated cement beads, and five (15%) required two or more first-stage procedures. The most common organism isolated was coagulase-negative Staphylococcus in 21 TEAs (62%).

A second-stage procedure was performed for 26 TEAs (76%); seven patients (seven TEAs, 21%) had a functional resection arthroplasty with antibiotic beads in situ and had no further surgery, one had a persistent discharge preventing further surgery.

There were three recurrent infections (11.5%) in those patients who underwent a second-stage procedure. The infection presented at a mean of eight months (5 to 10) post-operatively. The mean Mayo Elbow Performance Score (MEPS) in those who underwent a second stage revision without recurrent infection was 81.1 (65 to 95).

Staged revision surgery is successful in the treatment of patients with an infected TEA and is associated with a low rate of recurrent infection. However, when infection does occur, this study would suggest that it becomes apparent within ten months of the second stage procedure.

Cite this article: Bone Joint J 2013;95-B:1681–6.


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 374 - 380
1 Mar 2016
Kocsis G Thyagarajan DS Fairbairn KJ Wallace WA

Aims. Glenoid bone loss can be a challenging problem when revising a shoulder arthroplasty. Precise pre-operative planning based on plain radiographs or CT scans is essential. We have investigated a new radiological classification system to describe the degree of medialisation of the bony glenoid and that will indicate the amount of bone potentially available for supporting a glenoid component. It depends on the relationship between the most medial part of the articular surface of the glenoid with the base of the coracoid process and the spinoglenoid notch: it classifies the degree of bone loss into three types. It also attempts to predict the type of glenoid reconstruction that may be possible (impaction bone grafting, structural grafting or simple non-augmented arthroplasty) and gives guidance about whether a pre-operative CT scan is indicated. Patients and Methods. Inter-method reliability between plain radiographs and CT scans was assessed retrospectively by three independent observers using data from 39 randomly selected patients. . Inter-observer reliability and test-retest reliability was tested on the same cohort using Cohen's kappa statistics. Correlation of the type of glenoid with the Constant score and its pain component was analysed using the Kruskal-Wallis method on data from 128 patients. Anatomical studies of the scapula were reviewed to explain the findings. Results. Excellent inter-method reliability, inter-observer and test-retest reliability were seen. The system did not correlate with the Constant score, but correlated well with its pain component. . Take home message: Our system of classification is a helpful guide to the degree of glenoid bone loss when embarking on revision shoulder arthroplasty. Cite this article: Bone Joint J 2016;98-B:374–80


The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 603 - 609
1 May 2018
Schnetzke M Rick S Raiss P Walch G Loew M

Aims

The aim of this study was to evaluate the clinical and radiological outcome of using an anatomical short-stem shoulder prosthesis to treat primary osteoarthritis of the glenohumeral joint.

Patients and Methods

A total of 66 patients (67 shoulders) with a mean age of 76 years (63 to 92) were available for clinical and radiological follow-up at two different timepoints (T1, mean 2.6 years, sd 0.5; T2, mean 5.3 years, sd 0.7). Postoperative radiographs were analyzed for stem angle, cortical contact, and filling ratio of the stem. Follow-up radiographs were analyzed for timing and location of bone adaptation (cortical bone narrowing, osteopenia, spot welds, and condensation lines). The bone adaptation was classified as low (between zero and three features of bone remodelling around the humeral stem) or high (four or more features).


The Bone & Joint Journal
Vol. 96-B, Issue 8 | Pages 1077 - 1081
1 Aug 2014
Nuttall D Birch A Haines JF Trail IA

Resurfacing of the humeral head is commonly used within the UK to treat osteoarthritis (OA) of the shoulder. We present the results of a small prospective randomised study of this procedure using the Global CAP prosthesis with two different coatings, Porocoat and DuoFix hydroxyapatite (HA). We followed two groups of ten patients with OA of the shoulder for two years after insertion of the prosthesis with tantalum marker beads, recording pain, Constant–Murley and American Shoulder and Elbow Surgeons (ASES) outcome scores, and using radiostereometric analysis to assess migration. The outcomes were similar to those of other series, with significant reductions in pain (p = 0.003) and an improvement in the Constant (p = 0.001) and ASES scores (p = 0.006). The mean migration of the prosthesis three months post-operatively was 0.78 mm (0.51 to 1.69) and 0.72 mm (0.33 to 1.45) for the Porocoat and DuoFix groups, respectively. Analysis of variance indicated that the rate of migration reached a plateau after three months post-operatively in both groups. At follow-up of two years the mean migration was 1 mm (sd 1 (0.25 to 3.32)); in the Porocoat group and 0.8 mm (sd 0.4 (0.27 to 1.45)) in the DuoFix HA group. Significant migration of the prosthesis was seen in one patient who had received an anterior humeral bone graft. This prosthesis was later revised after 2.7 years.

The addition of a coating of HA to the sintered surface does not improve fixation of this prosthesis.

Cite this article: Bone Joint J 2014;96-B:1077–81.


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1086 - 1092
1 Aug 2016
de Vos MJ Wagener ML Hannink G van der Pluijm M Verdonschot N Eygendaal D

Aims

Revision total elbow arthroplasty (TEA) is often challenging. The aim of this study was to report on the clinical and radiological results of revision arthroplasty of the elbow with the Latitude TEA.

Patients and Methods

Between 2006 and 2010 we used the Latitude TEA for revision in 18 consecutive elbows (17 patients); mean age 53 years (28 to 80); 14 women. A Kudo TEA was revised in 15 elbows and a Souter-Strathclyde TEA in three.

Stability, range of movement (ROM), visual analogue score (VAS) for pain and functional scores, Elbow Functional Assessment Scale (EFAS), the Functional Rating Index of Broberg and Morrey (FRIBM) and the Modified Andrews’ Elbow Scoring System (MAESS) were assessed pre-operatively and at each post-operative follow-up visit (six, 12 months and biennially thereafter). Radiographs were analysed for loosening, fractures and dislocation. The mean follow-up was 59 months (26 to 89).


Bone & Joint Open
Vol. 5, Issue 10 | Pages 818 - 824
2 Oct 2024
Moroder P Herbst E Pawelke J Lappen S Schulz E

Aims. The liner design is a key determinant of the constraint of a reverse total shoulder arthroplasty (rTSA). The aim of this study was to compare the degree of constraint of rTSA liners between different implant systems. Methods. An implant company’s independent 3D shoulder arthroplasty planning software (mediCAD 3D shoulder v. 7.0, module v. 2.1.84.173.43) was used to determine the jump height of standard and constrained liners of different sizes (radius of curvature) of all available companies. The obtained parameters were used to calculate the stability ratio (degree of constraint) and angle of coverage (degree of glenosphere coverage by liner) of the different systems. Measurements were independently performed by two raters, and intraclass correlation coefficients were calculated to perform a reliability analysis. Additionally, measurements were compared with parameters provided by the companies themselves, when available, to ensure validity of the software-derived measurements. Results. There were variations in jump height between rTSA systems at a given size, resulting in large differences in stability ratio between systems. Standard liners exhibited a stability ratio range from 126% to 214% (mean 158% (SD 23%)) and constrained liners a range from 151% to 479% (mean 245% (SD 76%)). The angle of coverage showed a range from 103° to 130° (mean 115° (SD 7°)) for standard and a range from 113° to 156° (mean 133° (SD 11°)) for constrained liners. Four arthroplasty systems kept the stability ratio of standard liners constant (within 5%) across different sizes, while one system showed slight inconsistencies (within 10%), and ten arthroplasty systems showed large inconsistencies (range 11% to 28%). The stability ratio of constrained liners was consistent across different sizes in two arthroplasty systems and inconsistent in seven systems (range 18% to 106%). Conclusion. Large differences in jump height and resulting degree of constraint of rTSA liners were observed between different implant systems, and in many cases even within the same implant systems. While the immediate clinical effect remains unclear, in theory the degree of constraint of the liner plays an important role for the dislocation and notching risk of a rTSA system. Cite this article: Bone Jt Open 2024;5(10):818–824


Bone & Joint Open
Vol. 5, Issue 10 | Pages 894 - 897
16 Oct 2024
Stoneham A Poon P Hirner M Frampton C Gao R

Aims. Body exhaust suits or surgical helmet systems (colloquially, ‘space suits’) are frequently used in many forms of arthroplasty, with the aim of providing personal protection to surgeons and, perhaps, reducing periprosthetic joint infections, although this has not consistently been borne out in systematic reviews and registry studies. To date, no large-scale study has investigated whether this is applicable to shoulder arthroplasty. We used the New Zealand Joint Registry to assess whether the use of surgical helmet systems was associated with lower all-cause revision or revision for deep infection in primary shoulder arthroplasties. Methods. We analyzed 16,000 shoulder arthroplasties (hemiarthroplasties, anatomical, and reverse geometry prostheses) recorded on the New Zealand Joint Registry from its inception in 2000 to the present day. We assessed patient factors including age, BMI, sex, and American Society of Anesthesiologists (ASA) grade, as well as whether or not the operation took place in a laminar flow operating theatre. Results. A total of 2,728 operations (17%) took place using surgical helmet systems. Patient cohorts were broadly similar in terms of indication for surgery (osteoarthritis, rheumatoid arthritis, fractures) and medical comorbidities (age and sex). There were 842 revisions (5% of cases) with just 98 for deep infection (0.6% of all cases or 11.6% of the revisions). There were no differences in all-cause revisions or revision for deep infection between the surgical helmet systems and conventional gowns (p = 0.893 and p = 0.911, respectively). Conclusion. We found no evidence that wearing a surgical helmet system reduces the incidence of periprosthetic joint infection in any kind of primary shoulder arthroplasty. We acknowledge the limitations of this registry study and accept that there may be other benefits in terms of personal protection, comfort, or visibility. However, given their financial and ecological footprint, they should be used judiciously in shoulder surgery. Cite this article: Bone Jt Open 2024;5(10):894–897


The Bone & Joint Journal
Vol. 101-B, Issue 2 | Pages 147 - 153
1 Feb 2019
Mai DH Oh C Doany ME Rokito AS Kwon YW Zuckerman JD Virk MS

Aims. The aim of this study was to investigate the effects of preoperative bisphosphonate treatment on the intra- and postoperative outcomes of arthroplasty of the shoulder. The hypothesis was that previous bisphosphonate treatment would adversely affect both intra- and postoperative outcomes. Patients and Methods. A retrospective cohort study was conducted involving patients undergoing arthroplasty of the shoulder, at a single institution. Two patients with no previous bisphosphonate treatment were matched to each patient who had received this treatment preoperatively by gender, age, race, ethnicity, body mass index (BMI), and type of arthroplasty. Previous bisphosphonate treatment was defined as treatment occurring during the three-year period before the arthroplasty. The primary outcome measure was the incidence of intraoperative complications and those occurring at one and two years postoperatively. A total of 87 patients were included: 29 in the bisphosphonates-exposed (BP. +. ) group and 58 in the non-exposed (BP. -. ) group. In the BP. +. group, there were 26 female and three male patients, with a mean age of 71.4 years (51 to 87). In the BP. -. group, there were 52 female and six male patients, with a mean age of 72.1 years (53 to 88). Results. Previous treatment with bisphosphonates was positively associated with intraoperative complications (fracture; odds ratio (OR) 39.40, 95% confidence interval (CI) 2.42 to 6305.70) and one-year postoperative complications (OR 7.83, 95% CI 1.11 to 128.82), but did not achieve statistical significance for complications two years postoperatively (OR 3.45, 95% CI 0.65 to 25.28). The power was 63% for complications at one year. Conclusion. Patients who are treated with bisphosphonates during the three-year period before shoulder arthroplasty have a greater risk of intraoperative and one-year postoperative complications compared with those without this previous treatment


Bone & Joint Open
Vol. 5, Issue 7 | Pages 543 - 549
3 Jul 2024
Davies AR Sabharwal S Reilly P Sankey RA Griffiths D Archer S

Aims

Shoulder arthroplasty is effective in the management of end-stage glenohumeral joint arthritis. However, it is major surgery and patients must balance multiple factors when considering the procedure. An understanding of patients’ decision-making processes may facilitate greater support of those considering shoulder arthroplasty and inform the outcomes of future research.

Methods

Participants were recruited from waiting lists of three consultant upper limb surgeons across two NHS hospitals. Semi-structured interviews were conducted with 12 participants who were awaiting elective shoulder arthroplasty. Transcribed interviews were analyzed using a grounded theory approach. Systematic coding was performed; initial codes were categorized and further developed into summary narratives through a process of discussion and refinement. Data collection and analyses continued until thematic saturation was reached.


Bone & Joint Open
Vol. 4, Issue 2 | Pages 110 - 119
21 Feb 2023
Macken AA Prkić A van Oost I Spekenbrink-Spooren A The B Eygendaal D

Aims

The aim of this study is to report the implant survival and factors associated with revision of total elbow arthroplasty (TEA) using data from the Dutch national registry.

Methods

All TEAs recorded in the Dutch national registry between 2014 and 2020 were included. The Kaplan-Meier method was used for survival analysis, and a logistic regression model was used to assess the factors associated with revision.


Bone & Joint Open
Vol. 4, Issue 8 | Pages 567 - 572
3 Aug 2023
Pasache Lozano RDP Valencia Ramón EA Johnston DG Trenholm JAI

Aims

The aim of this study is to evaluate the change in incidence rate of shoulder arthroplasty, indications, and surgeon volume trends associated with these procedures between January 2003 and April 2021 in the province of Nova Scotia, Canada.

Methods

A total of 1,545 patients between 2005 and 2021 were analyzed. Patients operated on between 2003 and 2004 were excluded due to a lack of electronic records. Overall, 84.1% of the surgeries (n = 1,299) were performed by two fellowship-trained upper limb surgeons, with the remainder performed by one of the 14 orthopaedic surgeons working in the province.


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 912 - 919
1 Aug 2023
Cunningham LJ Walton M Bale S Trail IA

Aims

Reverse total shoulder arthroplasty (rTSA) can be used in complex cases when the glenoid requires reconstruction. In this study, a baseplate with composite bone autograft and a central trabecular titanium peg was implanted, and its migration was assessed for two years postoperatively using radiostereometric analysis (RSA).

Methods

A total of 14 patients who underwent a rTSA with an autograft consented to participate. Of these, 11 had a primary rTSA using humeral head autograft and three had a revision rTSA with autograft harvested from the iliac crest. The mean age of the patients was 66 years (39 to 81). Tantalum beads were implanted in the scapula around the glenoid. RSA imaging (stereographic radiographs) was undertaken immediately postoperatively and at three, six, 12, and 24 months. Analysis was completed using model-based RSA software. Outcomes were collected preoperatively and at two years postoperatively, including the Oxford Shoulder Score, the American Shoulder and Elbow Score, and a visual analogue score for pain. A Constant score was also obtained for the assessment of strength and range of motion.