Advertisement for orthosearch.org.uk
Results 1 - 20 of 927
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 817 - 825
1 Aug 2024
Borukhov I Ismailidis P Esposito CI LiArno S Lyon J McEwen PJ

Aims. This study aimed to evaluate if total knee arthroplasty (TKA) femoral components aligned in either mechanical alignment (MA) or kinematic alignment (KA) are more biomimetic concerning trochlear sulcus orientation and restoration of trochlear height. Methods. Bone surfaces from 1,012 CT scans of non-arthritic femora were segmented using a modelling and analytics system. TKA femoral components (Triathlon; Stryker) were virtually implanted in both MA and KA. Trochlear sulcus orientation was assessed by measuring the distal trochlear sulcus angle (DTSA) in native femora and in KA and MA prosthetic femoral components. Trochlear anatomy restoration was evaluated by measuring the differences in medial, lateral, and sulcus trochlear height between native femora and KA and MA prosthetic femoral components. Results. Femoral components in both MA and KA alignments exhibited a more valgus DTSA compared to native femora. However, DTSA deviation from native was significantly less in KA than in MA (4.8° (SD 2.2°) vs 8.8° (SD 1.8°); p < 0.001). DTSA deviation from native orientation correlated positively with the mechanical lateral distal femoral angle (mLDFA) in KA and negatively in MA (r = 0.53, p < 0.001; r = -0.18, p < 0.001). Medial trochlear height was not restored with either MA or KA, with MA resulting in lower medial trochlear height than KA in the proximal 20% of the trochlea. Lateral and sulcus trochlear height was not restored with either alignment in the proximal 80% of the trochlea. At the terminal arc point, KA replicated sulcus and lateral trochlear height, while MA led to over-restoration. Conclusion. Femoral components aligned in KA demonstrated greater biomimetic qualities than those in MA regarding trochlear sulcus orientation and trochlear height restoration, particularly in valgus femora. Variability across knees was observed, warranting further research to evaluate the clinical implications of these findings. Cite this article: Bone Joint J 2024;106-B(8):817–825


Bone & Joint Research
Vol. 13, Issue 6 | Pages 306 - 314
19 Jun 2024
Wu B Su J Zhang Z Zeng J Fang X Li W Zhang W Huang Z

Aims. To explore the clinical efficacy of using two different types of articulating spacers in two-stage revision for chronic knee periprosthetic joint infection (kPJI). Methods. A retrospective cohort study of 50 chronic kPJI patients treated with two types of articulating spacers between January 2014 and March 2022 was conducted. The clinical outcomes and functional status of the different articulating spacers were compared. Overall, 17 patients were treated with prosthetic spacers (prosthetic group (PG)), and 33 patients were treated with cement spacers (cement group (CG)). The CG had a longer mean follow-up period (46.67 months (SD 26.61)) than the PG (24.82 months (SD 16.46); p = 0.001). Results. Infection was eradicated in 45 patients overall (90%). The PG had a better knee range of motion (ROM) and Knee Society Score (KSS) after the first-stage revision (p = 0.004; p = 0.002), while both groups had similar ROMs and KSSs at the last follow-up (p = 0.136; p = 0.895). The KSS in the CG was significantly better at the last follow-up (p = 0.013), while a larger percentage (10 in 17, 58.82%) of patients in the PG chose to retain the spacer (p = 0.008). Conclusion. Prosthetic spacers and cement spacers are both effective at treating chronic kPJI because they encourage infection control, and the former improved knee function status between stages. For some patients, prosthetic spacers may not require reimplantation. Cite this article: Bone Joint Res 2024;13(6):306–314


Bone & Joint Research
Vol. 8, Issue 8 | Pages 387 - 396
1 Aug 2019
Alt V Rupp M Lemberger K Bechert T Konradt T Steinrücke P Schnettler R Söder S Ascherl R

Objectives. Preclinical data showed poly(methyl methacrylate) (PMMA) loaded with microsilver to be effective against a variety of bacteria. The purpose of this study was to assess patient safety of PMMA spacers with microsilver in prosthetic hip infections in a prospective cohort study. Methods. A total of 12 patients with prosthetic hip infections were included for a three-stage revision procedure. All patients received either a gentamicin-PMMA spacer (80 g to 160 g PMMA depending on hip joint dimension) with additional loading of 1% (w/w) of microsilver (0.8 g to 1.6 g per spacer) at surgery 1 followed by a gentamicin-PMMA spacer without microsilver at surgery 2 or vice versa. Implantation of the revision prosthesis was carried out at surgery 3. Results. In total, 11 of the 12 patients completed the study. No argyria or considerable differences in laboratory parameters were detected. Silver blood concentrations were below or around the detection limit of 1 ppb in ten of the 11 patients. A maximum of 5.6 ppb at 48 hours after implantation of the silver spacer, which is below the recommended maximum level of 10 ppb, was found in one patient. No silver was detected in the urine. Drainage fluids showed concentrations between 16.1 ppb and 23.3 ppb at 12 hours after implantation of the silver spacers, and between 16.8 ppb to 25.1 ppb at 48 hours after implantation. Pathohistological assessment of the periprosthetic membrane did not reveal any differences between the two groups. Conclusion. Microsilver-loaded gentamicin-PMMA spacers showed good biocompatibility and the broad antimicrobial activity warrants further clinical research to assess its effectivity in reducing infection rates in prosthetic joint infection. Cite this article: V. Alt, M. Rupp, K. Lemberger, T. Bechert, T. Konradt, P. Steinrücke, R. Schnettler, S. Söder, R. Ascherl. Safety assessment of microsilver-loaded poly(methyl methacrylate) (PMMA) cement spacers in patients with prosthetic hip infections: Results of a prospective cohort study. Bone Joint Res 2019;8:387–396. DOI: 10.1302/2046-3758.88.BJR-2018-0270.R1


Bone & Joint Research
Vol. 10, Issue 10 | Pages 690 - 692
1 Oct 2021
Hoellwarth JS Tetsworth K Akhtar MA Al Muderis M


The Bone & Joint Journal
Vol. 101-B, Issue 4 | Pages 372 - 377
1 Apr 2019
Zagra L Villa F Cappelletti L Gallazzi E Materazzi G De Vecchi E

Aims. Leucocyte esterase (LE) has been shown to be an accurate marker of prosthetic joint infection (PJI), and has been proposed as an alternative to frozen section (FS) histology for intraoperative diagnosis. In this study, the intraoperative assessment of LE was compared with FS histology for the diagnosis of prosthetic hip infection. Patients and Methods. A total of 119 patients undergoing revision total hip arthroplasty (THA) between June 2015 and December 2017 were included in the study. There were 56 men and 63 women with a mean age of 66.2 years (27 to 88). Synovial fluid was collected before arthrotomy for the assessment of LE using enzymatic colourimetric strips. Between five and six samples were stained with haematoxylin and eosin for FS histology, and considered suggestive of infection when at least five polymorphonuclear leucocytes were found in five high-power fields. Results. The sensitivity and specificity of the LE assay were 100% and 93.8%, respectively; the positive (PPV) and the negative (NPV) predictive values were 79.3% and 100%, respectively. The mean time between the collection of the sample and the result being known was 20.1 minutes (. sd. 4.4). The sensitivity and specificity of FS histology were 78.3% and 96.9%, respectively; the PPV and the NPV were 85.7% and 94.9%, respectively. The mean time between the collection of the sample and the result being known was 27.2 minutes (. sd. 6.9). Conclusion. The sensitivity of LE assay was higher, with similar specificity and diagnostic accuracy, compared with FS histology. The faster turnaround time, its ease of use, and low costs make LE assay a valuable alternative to FS histology. We now use it routinely for the intraoperative diagnosis of PJI. Cite this article: Bone Joint J 2019;101-B:372–377


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 825 - 826
1 Jul 2008
Oswald TF Gould FK

The routine administration of prophylactic antibiotics for dental interventions to prevent haematogenous spread of infections to prosthetic joints is a contentious issue. In this editorial we discuss the potentially harmful effects of this practice and propose an alternative solution


The Journal of Bone & Joint Surgery British Volume
Vol. 39-B, Issue 2 | Pages 233 - 247
1 May 1957
McKenzie DS

1. Congenital defects of the extremities are described. Although the detailed anatomy is infinitely variable, a broad classification in relation to prosthetic management has been suggested. 2. Most patients with these deformities can be fitted with a prosthesis without major surgical intervention. With this they will have at least as good function as they would have after amputation. A plea is made for a conservative attitude in this respect. It is suggested that recourse to amputation should be confined to cases in which prosthetic equipment falls short of functional and cosmetic requirements, and that, when possible, it should be deferred until the child is old enough to share in the decision. 3. The prostheses applicable to the various types of deformity are briefly described. 4. The application of similar techniques to cases of acquired shortening is mentioned. 5. The incorporation of certain features of artificial arms in flail arm splints is discussed


Bone & Joint Research
Vol. 12, Issue 8 | Pages 497 - 503
16 Aug 2023
Lee J Koh Y Kim PS Park J Kang K

Aims

Focal knee arthroplasty is an attractive alternative to knee arthroplasty for young patients because it allows preservation of a large amount of bone for potential revisions. However, the mechanical behaviour of cartilage has not yet been investigated because it is challenging to evaluate in vivo contact areas, pressure, and deformations from metal implants. Therefore, this study aimed to determine the contact pressure in the tibiofemoral joint with a focal knee arthroplasty using a finite element model.

Methods

The mechanical behaviour of the cartilage surrounding a metal implant was evaluated using finite element analysis. We modelled focal knee arthroplasty with placement flush, 0.5 mm deep, or protruding 0.5 mm with regard to the level of the surrounding cartilage. We compared contact stress and pressure for bone, implant, and cartilage under static loading conditions.


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 4 | Pages 643 - 646
1 Jul 1990
Mulroy R Mankin H Harris W

We describe a patient in whom a total hip replacement had failed and who subsequently fractured her proximal femur. The prosthetic hip and the surrounding bone were excised and replaced by a matched pair of allograft components. She obtained seven years of pain free hip function before the graft showed radiographic signs of failure; it was then replaced by a new prosthetic hip


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 582 - 588
1 May 2019
Sidhu MS Cooper G Jenkins N Jeys L Parry M Stevenson JD

Aims

The aims of this study were to report the efficacy of revision surgery for patients with co-infective bacterial and fungal prosthetic joint infections (PJIs) presenting to a single institution, and to identify prognostic factors that would guide management.

Patients and Methods

A total of 1189 patients with a PJI were managed in our bone infection service between 2006 and 2015; 22 (1.85%) with co-infective bacterial and fungal PJI were included in the study. There were nine women and 13 men, with a mean age at the time of diagnosis of 64.5 years (47 to 83). Their mean BMI was 30.9 kg/m2 (24 to 42). We retrospectively reviewed the outcomes of these PJIs, after eight total hip arthroplasties and 14 total knee arthroplasties. The mean clinical follow-up was 4.1 years (1.4 to 8.8).


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 6 | Pages 1038 - 1043
1 Nov 1990
Radford W Amis A

We have assessed the biomechanical properties of a 'double-bundle' prosthetic ligament replacing the anterior cruciate in cadaver knees. We compared the results with those of single bundle 'over-the-top' and 'through-the-condyle' techniques, performing anterior drawer tests at 20 degrees and 90 degrees knee flexion. The over-the-top reconstruction gave better anteroposterior stability at 20 degrees, while the through-the-condyle repair was more stable at 90 degrees. The double-bundle reconstruction gave practically normal anterior stability at both 20 degrees and 90 degrees


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 5 | Pages 818 - 821
1 Sep 1993
Mody B Howard L Harding M Parmar H Learmonth D

We treated 39 knees with chronic deficiency of the anterior cruciate ligament by reconstruction using the ABC carbon and polyester prosthetic ligament; 31 (79.5%) were reviewed at an average follow-up of 34 months. There had been four complete failures requiring revision. The remaining 27 were studied in detail. On the Lysholm rating, only 11 knees (41%) had good results with a score of over 76. The mean anterior drawer movement was reduced from 7.6 mm before operation to 5.8 mm at review. The mean difference from the opposite uninjured knee was 3.9 mm before operation, 1 mm (in 21 patients) at mean follow-up of 7.4 months and 2.5 mm (in 27 patients) at 34 months, indicating progressive loss of effect. In our opinion the results are unsatisfactory: we do not recommend the use of this prosthetic ligament


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 4 | Pages 647 - 652
1 Aug 1986
Pring D Henderson R Rivett A Krausz T Coombs R Lavender J

To detect sepsis in the painful joint, autologous granulocytes labelled with indium-111 were used to scan 60 patients with 74 prosthetic joints. All 18 patients with confirmed sepsis had positive scans, that is, migration of granulocytes into the region of the prosthesis. Of the 22 sterile arthroplasties 20 had negative scans. In 34 cases there was good correlation between the clinical impression and the result of the scan. We suggest that indium granulocyte scintigraphy is a reliable method of detecting an infected prosthesis


The Journal of Bone & Joint Surgery British Volume
Vol. 60-B, Issue 4 | Pages 552 - 560
1 Nov 1978
Herberts P Almstrom C Caine K

A control system for a multifunctional hand prosthesis, which requires a minimum of training for the amputee, has been developed. The great advantage of the pattern recognition technique in making it possible to control as many as six prosthetic movements has prompted this study. The development of a complete miniaturised system has allowed a clinical trial on four patients. Two different tests have been employed to evaluate this system: an objective computer test and a test representing activities of daily living (ADL test). The computer test shows that a high rate of correct recognition is obtained immediately after the prosthesis is applied to the amputee. The ADL test shows that forearm rotation, and flexion and extension of the wrist are used in most activities, indicating that few compensatory movements are performed. It is suggested that this control system is feasible and that long periods of training are unnecessary


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 2 | Pages 183 - 184
1 Mar 2001
Bruce ASW Kerry RM Norman P Stockley I

We report two cases of fungal infection of prosthetic joints which were successfully treated by the incorporation of fluconazole into polymethylmethacrylate beads inserted at the time of debridement


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 3 | Pages 531 - 539
1 May 1998
Goodman SB Huie P Song Y Schurman D Maloney W Woolson S Sibley R

The tissues surrounding 65 cemented and 36 cementless total joint replacements undergoing revision were characterised for cell types by immunohistochemistry and for cytokine expression by in situ hybridisation. We identified three distinct groups of revised implants: loose implants with ballooning radiological osteolysis, loose implants without osteolysis, and well-fixed implants. In the cemented series, osteolysis was associated with increased numbers of macrophages (p = 0.0006), T-lymphocyte subgroups (p = 0.03) and IL-1 (p = 0.02) and IL-6 (p = 0.0001) expression, and in the cementless series with increased numbers of T-lymphocyte subgroups (p = 0.005) and increased TNFα expression (p = 0.04). For cemented implants, the histological, histochemical and cytokine profiles of the interface correlated with the clinical and radiological grade of loosening and osteolysis. Our findings suggest that there are different biological mechanisms of loosening and osteolysis for cemented and cementless implants. T-lymphocyte modulation of macrophage function may be an important interaction at prosthetic interfaces


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 5 | Pages 816 - 819
1 Sep 1997
An YH Bradley J Powers DL Friedman RJ

We evaluated the effects of a serum protein coating on prosthetic infection in 29 adult male rabbits divided into three groups: control, albumin-coated and uncoated. We used 34 grit-blasted, commercially pure titanium implants. Eleven were coated with cross-linked albumin. All the implants were exposed to a suspension of Staphylococcus epidermidis before implantation. Our findings showed that albumin-coated implants had a much lower infection rate (27%) than the uncoated implants (62%). This may be a useful method of reducing the infection of prostheses


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 5 | Pages 586 - 589
1 Dec 1982
Cole W Klein R van Lith M Jarvis R

A programme for early mobilisation using a temporary prosthesis was evaluated in 17 children who had had an amputation above the knee for sarcomata. The temporary prosthesis had a performed adjustable polypropylene quadrilateral socket which was able to accommodate changes in the size of the stump during the first few months after amputation. The adjustable sockets were assembled onto wooden knee-shank-foot units or onto modular components covered with foam. The wooden units were better for routine use as more adjustment was possible between the socket and the knee and because they were more durable in active children. Prosthetic fitting usually took one hour and was carried out 10 days after the amputation to coincide with the start of the chemotherapy programme. The prosthesis was cosmetically acceptable, easy to use and provided a simple and economical way of rehabilitating the amputees and restoring their morale. After two to three months a new prosthesis with a laminated socket suspended by a waistband was supplied. The skin tolerated the closer fit of this socket and the small fluctuations in the size of the stump that occurred with each course of chemotherapy were easily accommodated by varying the thickness of the stump sock. A self-suspending laminated socket was provided after completion of the chemotherapy. The permanent sockets were assembled onto wooden components but the girls usually preferred the modular system covered with foam. The chemotherapy and rehabilitation programmes were successfully co-ordinated so that the children spent as little time as possible away from their normal activities


Aims

Methicillin-resistant Staphylococcus aureus (MRSA) can cause wound infections via a ‘Trojan Horse’ mechanism, in which neutrophils engulf intestinal MRSA and travel to the wound, releasing MRSA after apoptosis. The possible role of intestinal MRSA in prosthetic joint infection (PJI) is unknown.

Methods

Rats underwent intestinal colonization with green fluorescent protein (GFP)-tagged MRSA by gavage and an intra-articular wire was then surgically implanted. After ten days, the presence of PJI was determined by bacterial cultures of the distal femur, joint capsule, and implant. We excluded several other possibilities for PJI development. Intraoperative contamination was excluded by culturing the specimen obtained from surgical site. Extracellular bacteraemia-associated PJI was excluded by comparing with the infection rate after intravenous injection of MRSA or MRSA-carrying neutrophils. To further support this theory, we tested the efficacy of prophylactic membrane-permeable and non-membrane-permeable antibiotics in this model.


The Bone & Joint Journal
Vol. 100-B, Issue 9 | Pages 1157 - 1161
1 Sep 2018
Brown TS Fehring KA Ollivier M Mabry TM Hanssen AD Abdel MP

Aims

Recurrent infection following two-stage revision total hip arthroplasty (THA) for prosthetic joint infection (PJI) is a devastating complication. The purpose of this study was to report the survival of repeat two-stage revision hip arthroplasty, describe complications, and identify risk factors for failure.

Patients and Methods

We retrospectively identified 19 hips (19 patients) that had undergone repeat two-stage revision THA for infection between 2000 to 2013. There were seven female patients (37%) and the mean age was 60 years (30 to 85). Survival free from revision was assessed via Kaplan–Meier analysis. The patients were classified according to the Musculoskeletal Infection Society (MSIS) system, and risk factors for failure were identified. Mean follow-up was four years (2 to 11).