A new generation of knee prostheses has been introduced with the intention of improving post-operative knee flexion. In order to evaluate whether this goal has been achieved we performed a systematic review and meta-analysis. Systematic literature searches were conducted on MEDLINE and EMBASE from their inception to December 2007, and proceedings of scientific meetings were also searched. Only randomised, clinical trials were included in the meta-analysis. The mean difference in the maximum post-operative flexion between the ‘high-flex’ and conventional types of prosthesis was defined as the primary outcome measure. A total of five relevant articles was identified. Analysis of these trials suggested that no clinically relevant or statistically significant improvement was obtained in flexion with the ‘high-flex’ prostheses. The weighted mean difference was 2.1° (95% confidence interval −0.2 to +4.3; p = 0.07).
Objectives. Effective analgesia after total knee arthroplasty (TKA) improves
patient satisfaction, mobility and expedites discharge. This study
assessed whether continuous femoral nerve infusion (CFNI) was superior
to a single-shot femoral nerve block in primary TKA surgery completed
under subarachnoid blockade including morphine. Methods. We performed an adequately powered, prospective, randomised,
placebo-controlled trial comparing CFNI of 0.125% bupivacaine versus normal
saline following a single-shot femoral nerve block and subarachnoid
anaesthesia with intrathecal morphine for primary TKA. Patients
were randomised to either treatment (CFNI 0 ml to 10 ml/h 0.125%
bupivacaine) or placebo (CFNI 0 ml to 10 ml/h normal saline). Both
groups received a single-shot femoral nerve block (0.25% 20 ml bupivacaine)
prior to placement of femoral nerve catheter and subarachnoid anaesthesia with
intrathecal morphine. All patients had a standardised analgesic
protocol. The primary end point was post-operative visual analogue
scale (VAS) pain score over 72 hours post-surgery. Secondary outcomes
were morphine equivalent dose, range of
We report a prospective randomly controlled trial to examine the effectiveness of continuous passive motion (CPM) in improving postoperative function and range of
The COVID-19 pandemic posed significant challenges to healthcare systems across the globe in 2020. There were concerns surrounding early reports of increased mortality among patients undergoing emergency or non-urgent surgery. We report the morbidity and mortality in patients who underwent arthroplasty procedures during the UK first stage of the pandemic. Institutional review board approval was obtained for a review of prospectively collected data on consecutive patients who underwent arthroplasty procedures between March and May 2020 at a specialist orthopaedic centre in the UK. Data included diagnoses, comorbidities, BMI, American Society of Anesthesiologists grade, length of stay, and complications. The primary outcome was 30-day mortality and secondary outcomes were prevalence of SARS-CoV-2 infection, medical and surgical complications, and readmission within 30 days of discharge. The data collated were compared with series from the preceding three months.Aims
Methods
The diagnosis of periprosthetic joint infection (PJI) can be difficult. All current diagnostic tests have problems with accuracy and interpretation of results. Many new tests have been proposed, but there is no consensus on the place of many of these in the diagnostic pathway. Previous attempts to develop a definition of PJI have not been universally accepted and there remains no reference standard definition. This paper reports the outcome of a project developed by the European Bone and Joint Infection Society (EBJIS), and supported by the Musculoskeletal Infection Society (MSIS) and the European Society of Clinical Microbiology and Infectious Diseases (ESCMID) Study Group for Implant-Associated Infections (ESGIAI). It comprised a comprehensive review of the literature, open discussion with Society members and conference delegates, and an expert panel assessment of the results to produce the final guidance.Aims
Methods
The enhanced recovery after surgery (ERAS) concept in arthroplasty surgery has led to a reduction in postoperative length of stay in recent years. Patients with prolonged length of stay (PLOS) add to the burden of a strained NHS. Our aim was to identify the main reasons. A PLOS was arbitrarily defined as an inpatient hospital stay of four days or longer from admission date. A total of 2,000 consecutive arthroplasty patients between September 2017 and July 2018 were reviewed. Of these, 1,878 patients were included after exclusion criteria were applied. Notes for 524 PLOS patients were audited to determine predominant reasons for PLOS.Introduction
Methods
Arthrofibrosis is a relatively common complication after joint injuries and surgery, particularly in the knee. The present study used a previously described and validated rabbit model to assess the biomechanical, histopathological, and molecular effects of the mast cell stabilizer ketotifen on surgically induced knee joint contractures in female rabbits. A group of 12 skeletally mature rabbits were randomly divided into two groups. One group received subcutaneous (SQ) saline, and a second group received SQ ketotifen injections. Biomechanical data were collected at eight, ten, 16, and 24 weeks. At the time of necropsy, posterior capsule tissue was collected for histopathological and gene expression analyses (messenger RNA (mRNA) and protein).Aims
Methods
The lateral subvastus approach combined with an osteotomy of the tibial tubercle is a recognised, but rarely used approach for total knee replacement (TKR). A total of 32 patients undergoing primary TKR was randomised into two groups, in one of which the lateral subvastus approach combined with a tibial tubercle osteotomy and in the other the medial parapatellar approach were used. The patients were assessed radiologically and clinically using measurement of the range of
The aim of this study was to conduct the largest low contact stress (LCS) retrieval study to elucidate the failure mechanisms of the Porocoat and Duofix femoral component. The latter design was voluntarily recalled by the manufacturer. Uncemented LCS explants were divided into three groups: Duofix, Porocoat, and mixed. Demographics, polyethylene wear, tissue ingrowth, and metallurgical analyses were performed.Aims
Materials and Methods
This study aimed to develop a virtual clinic for the purpose of reducing face-to-face orthopaedic consultations. Anonymized experts (hip and knee arthroplasty patients, surgeons, physiotherapists, radiologists, and arthroplasty practitioners) gave feedback via a Delphi Consensus Technique. This consisted of an iterative sequence of online surveys, during which virtual documents, made up of a patient-reported questionnaire, standardized radiology report, and decision-guiding algorithm, were modified until consensus was achieved. We tested the patient-reported questionnaire on seven patients in orthopaedic clinics using a ‘think-aloud’ process to capture difficulties with its completion.Aims
Patients and Methods
We randomised 102 knees suitable for a unicompartmental replacement to receive either a unicompartmental (UKR) or total knee replacement (TKR) after arthrotomy. Both groups were well matched with a predominance of females and a mean age of 69 years. Patients in the UKR group showed less perioperative morbidity, but regained knee
Survival analysis of joint replacement relies on the assumption that surgical procedures in patients lost to follow-up have the same chance of failing as those in patients who continue to be assessed. Our study questions that assumption. During the 16-year follow-up of 2268 patients who had received total hip replacements 142 (6%) were lost to follow-up. The cumulative loss at 15 years was 20%. At their last assessment, patients who subsequently failed to attend for follow-up had significantly worse pain, range of
Aims
Patients and Methods
The interaction between surgical lighting and laminar airflow
is poorly understood. We undertook an experiment to identify any
effect contemporary surgical lights have on laminar flow and recommend
practical strategies to limit any negative effects. Neutrally buoyant bubbles were introduced into the surgical field
of a simulated setup for a routine total knee arthroplasty in a
laminar flow theatre. Patterns of airflow were observed and the
number of bubbles remaining above the surgical field over time identified.
Five different lighting configurations were assessed. Data were analysed
using simple linear regression after logarithmic transformation.Aims
Materials and Methods
Valgus knee deformity can present a number of
unique surgical challenges for the total knee arthroplasty (TKA)
surgeon. Understanding the typical patterns of bone and soft-tissue pathology
in the valgus arthritic knee is critical for appropriate surgical
planning. This review aims to provide the knee arthroplasty surgeon
with an understanding of surgical management strategies for the
treatment of valgus knee arthritis. Lateral femoral and tibial deficiencies, contracted lateral soft
tissues, attenuated medial soft tissues, and multiplanar deformities
may all be present in the valgus arthritic knee. A number of classifications
have been reported in order to guide surgical management, and a variety
of surgical strategies have been described with satisfactory clinical
results. Depending on the severity of the deformity, a variety of
TKA implant designs may be appropriate for use. Regardless of an operating surgeon’s preferred surgical strategy,
adherence to a step-wise approach to deformity correction is advised. Cite this article:
We investigated changes in the axial alignment of the ipsilateral
hip and knee after total hip arthroplasty (THA). We reviewed 152 patients undergoing primary THA (163 hips; 22
hips in men, 141 hips in women) without a pre-operative flexion
contracture. The mean age was 64 years (30 to 88). The diagnosis
was osteoarthritis (OA) in 151 hips (primary in 18 hips, and secondary
to dysplasia in 133) and non-OA in 12 hips. A posterolateral approach
with repair of the external rotators was used in 134 hips and an
anterior approach in 29 hips. We measured changes in leg length
and offset on radiographs, and femoral anteversion, internal rotation
of the hip and lateral patellar tilt on CT scans, pre- and post-operatively. Aims
Patients and Methods
There is uncertainty regarding the optimal means of thromboprophylaxis
following total hip and knee arthroplasty (THA, TKA). This systematic
review presents the evidence for acetylsalicylic acid (aspirin)
as a thromboprophylactic agent in THA and TKA and compares it with
other chemoprophylactic agents. A search of literature published between 2004 and 2014 was performed
in accordance with Preferred Reporting Items for Systematic Reviews
and Meta-Analyses guidelines. A total of 13 studies were eligible
for inclusion.Aims
Materials and Methods
Tissue responses to debris formed by abrasion of polymethylmethacrylate
(PMMA) spacers at two-stage revision arthroplasty for prosthetic
joint infection are not well described. We hypothesised that PMMA
debris induces immunomodulation in periprosthetic tissues. Samples of tissue were taken during 35 two-stage revision arthroplasties
(nine total hip and 26 total knee arthroplasties) in patients whose
mean age was 67 years (44 to 85). Fourier transform infrared microscopy
was used to confirm the presence of PMMA particles. Histomorphometry
was performed using Sudan Red and Haematoxylin-Eosin staining.
CD-68, CD-20, CD-11(c), CD-3 and IL-17 antibodies were used to immunophenotype
the inflammatory cells. All slides were scored semi-quantitatively
using the modified Willert scoring system.Aims
Patients and Methods
During the last ten years, greater attention
has been given to the management of peri-operative blood loss after
total knee arthroplasty (TKA), as it is a modifiable outcome that has
a significant effect on the rate of complications, the recovery,
and the economic burden. Blood loss after TKA has been greatly reduced
during this time, thereby dramatically reducing the rates of allogeneic
transfusion. This has significantly reduced the complications associated
with transfusion, such as fluid overload, infection, and increased length
of stay. The greatest advent in lowering peri-operative blood loss after
TKA has been the introduction of tranexamic acid, which reduces
blood loss without increasing the risk of thromboembolic events. This paper discusses the ways of reducing blood loss after TKA,
for which a multimodal algorithm, with pre-, intra- and post-operative
measures, has been adopted at our institution. Cite this article:
The purpose of this study was to evaluate the
effect of various non-operative modalities of treatment (transcutaneous
electrical nerve stimulation (TENS); neuromuscular electrical stimulation
(NMES); insoles and bracing) on the pain of osteoarthritis (OA)
of the knee. We conducted a systematic review according to the Preferred Reporting
Items for Systematic Reviews and Meta-Analyses guidelines to identify
the therapeutic options which are commonly adopted for the management
of osteoarthritis (OA) of the knee. The outcome measurement tools used in the different studies were
the visual analogue scale and The Western Ontario and McMaster Universities
Arthritis Index pain index: all pain scores were converted to a
100-point scale. A total of 30 studies met our inclusion criteria: 13 on insoles,
seven on TENS, six on NMES, and four on bracing. The standardised
mean difference (SMD) in pain after treatment with TENS was 1.796,
which represented a significant reduction in pain. The significant
overall effect estimate for NMES on pain was similar to that of
TENS, with a SMD of 1.924. The overall effect estimate of insoles
on pain was a SMD of 0.992. The overall effect of bracing showed
a significant reduction in pain of 1.34. Overall, all four non-operative modalities of treatment were
found to have a significant effect on the reduction of pain in OA
of the knee. This study shows that non-operative physical modalities of treatment
are of benefit when treating OA of the knee. However, much of the
literature reviewed evaluates studies with follow-up of less than
six months: future work should aim to evaluate patients with longer
follow-up. Cite this article: