The Bone & Joint Journal
Vol. 104-B, Issue 3 | Pages 352 - 358
1 Mar 2022
Kleeman-Forsthuber L Vigdorchik JM Pierrepont JW Dennis DA

Aims

Pelvic incidence (PI) is a position-independent spinopelvic parameter traditionally used by spinal surgeons to determine spinal alignment. Its relevance to the arthroplasty surgeon in assessing patient risk for total hip arthroplasty (THA) instability preoperatively is unclear. This study was undertaken to investigate the significance of PI relative to other spinopelvic parameter risk factors for instability to help guide its clinical application.

Methods

Retrospective analysis was performed of a multicentre THA database of 9,414 patients with preoperative imaging (dynamic spinopelvic radiographs and pelvic CT scans). Several spinopelvic parameter measurements were made by engineers using advanced software including sacral slope (SS), standing anterior pelvic plane tilt (APPT), spinopelvic tilt (SPT), lumbar lordosis (LL), and PI. Lumbar flexion (LF) was determined by change in LL between standing and flexed-seated lateral radiographs. Abnormal pelvic mobility was defined as ∆SPT ≥ 20° between standing and flexed-forward positions. Sagittal spinal deformity (SSD) was defined as PI-LL mismatch > 10°.


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 2 | Pages 339 - 339
1 Mar 1996
CAPASSO G TESTA V MAFFULLI N


The Bone & Joint Journal
Vol. 96-B, Issue 4 | Pages 513 - 518
1 Apr 2014
Terrier A Ston J Larrea X Farron A

The three-dimensional (3D) correction of glenoid erosion is critical to the long-term success of total shoulder replacement (TSR). In order to characterise the 3D morphology of eroded glenoid surfaces, we looked for a set of morphological parameters useful for TSR planning. We defined a scapular coordinates system based on non-eroded bony landmarks. The maximum glenoid version was measured and specified in 3D by its orientation angle. Medialisation was considered relative to the spino-glenoid notch. We analysed regular CT scans of 19 normal (N) and 86 osteoarthritic (OA) scapulae. When the maximum version of OA shoulders was higher than 10°, the orientation was not only posterior, but extended in postero-superior (35%), postero-inferior (6%) and anterior sectors (4%). The medialisation of the glenoid was higher in OA than normal shoulders. The orientation angle of maximum version appeared as a critical parameter to specify the glenoid shape in 3D. It will be very useful in planning the best position for the glenoid in TSR.

Cite this article: Bone Joint J 2014;96-B:513–18.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 4 | Pages 570 - 575
1 Jul 1997
Boniforti FG Fujii G Angliss RD Benson MKD

We have evaluated the reliability of the measurement of radiological indicators in developmental dysplasia of the hip. Three observers each independently assessed 60 pelvic radiographs from infants aged from 3 to 36 months. Errors from the true value of a single measurement made by a single observer (E1), of the average of two measurements by a single observer (E2), and of the average of two single measurements by two different observers (E3) were established for the acetabular index of Hilgenreiner, for the assessment of superior and lateral femoral displacement and for indicators of pelvic alignment.

The errors for the assessment of the acetabular index were E1 ± 5°, E2 ± 5°, and E3 ± 3.5°. There was a significant correlation between the presence of an acetabular notch on the radiograph and an increased error in measurement (p = 0.01). Yamamuro’s measurement of lateral femoral displacement was more reliable than the Hilgenreiner distance. The errors of indicators of pelvic alignment showed a correlation with the age of the infant; the quotient of pelvic rotation was more reliable after seven months of age (p < 0.0001). The errors of the measurement of the symphysis os-ischium angle tended to increase with age and those of the measurement of the index of pelvic tilt decreased with skeletal maturation (p = 0.002).


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 2 | Pages 286 - 289
1 Mar 1996
Dwyer JSM Owen PJ Evans GA Kuiper JH Richardson JB

We describe a technique for measuring the Stiffness of regenerate bone after leg lengthening. This allows early identification of slow healing by reference to normal patterns. We determined the time of removal of the fixator from clinical and radiological information independent of the stiffness result.

In a series of 30 leg lengthenings there were no refractures when the tibial stiffness had reached 15 Nm/° or the femoral stiffness 20 Nm/°. Three refractures occurred at lower stiffness values. The technique is simple to perform, will allow a reduction in plain radiography and is recommended for routine postoperative management.


The Journal of Bone & Joint Surgery British Volume
Vol. 50-B, Issue 1 | Pages 244 - 244
1 Feb 1968
Manning CW


Bone & Joint Open
Vol. 4, Issue 5 | Pages 363 - 369
22 May 2023
Amen J Perkins O Cadwgan J Cooke SJ Kafchitsas K Kokkinakis M

Aims. Reimers migration percentage (MP) is a key measure to inform decision-making around the management of hip displacement in cerebral palsy (CP). The aim of this study is to assess validity and inter- and intra-rater reliability of a novel method of measuring MP using a smart phone app (HipScreen (HS) app). Methods. A total of 20 pelvis radiographs (40 hips) were used to measure MP by using the HS app. Measurements were performed by five different members of the multidisciplinary team, with varying levels of expertise in MP measurement. The same measurements were repeated two weeks later. A senior orthopaedic surgeon measured the MP on picture archiving and communication system (PACS) as the gold standard and repeated the measurements using HS app. Pearson’s correlation coefficient (r) was used to compare PACS measurements and all HS app measurements and assess validity. Intraclass correlation coefficient (ICC) was used to assess intra- and inter-rater reliability. Results. All HS app measurements (from 5 raters at week 0 and week 2 and PACS rater) showed highly significant correlation with the PACS measurements (p < 0.001). Pearson’s correlation coefficient (r) was constantly over 0.9, suggesting high validity. Correlation of all HS app measures from different raters to each other was significant with r > 0.874 and p < 0.001, which also confirms high validity. Both inter- and intra-rater reliability were excellent with ICC > 0.9. In a 95% confidence interval for repeated measurements, the deviation of each specific measurement was less than 4% MP for single measurer and 5% for different measurers. Conclusion. The HS app provides a valid method to measure hip MP in CP, with excellent inter- and intra-rater reliability across different medical and allied health specialties. This can be used in hip surveillance programmes by interdisciplinary measurers. Cite this article: Bone Jt Open 2023;4(5):363–369


Bone & Joint Open
Vol. 5, Issue 10 | Pages 818 - 824
2 Oct 2024
Moroder P Herbst E Pawelke J Lappen S Schulz E

Aims. The liner design is a key determinant of the constraint of a reverse total shoulder arthroplasty (rTSA). The aim of this study was to compare the degree of constraint of rTSA liners between different implant systems. Methods. An implant company’s independent 3D shoulder arthroplasty planning software (mediCAD 3D shoulder v. 7.0, module v. 2.1.84.173.43) was used to determine the jump height of standard and constrained liners of different sizes (radius of curvature) of all available companies. The obtained parameters were used to calculate the stability ratio (degree of constraint) and angle of coverage (degree of glenosphere coverage by liner) of the different systems. Measurements were independently performed by two raters, and intraclass correlation coefficients were calculated to perform a reliability analysis. Additionally, measurements were compared with parameters provided by the companies themselves, when available, to ensure validity of the software-derived measurements. Results. There were variations in jump height between rTSA systems at a given size, resulting in large differences in stability ratio between systems. Standard liners exhibited a stability ratio range from 126% to 214% (mean 158% (SD 23%)) and constrained liners a range from 151% to 479% (mean 245% (SD 76%)). The angle of coverage showed a range from 103° to 130° (mean 115° (SD 7°)) for standard and a range from 113° to 156° (mean 133° (SD 11°)) for constrained liners. Four arthroplasty systems kept the stability ratio of standard liners constant (within 5%) across different sizes, while one system showed slight inconsistencies (within 10%), and ten arthroplasty systems showed large inconsistencies (range 11% to 28%). The stability ratio of constrained liners was consistent across different sizes in two arthroplasty systems and inconsistent in seven systems (range 18% to 106%). Conclusion. Large differences in jump height and resulting degree of constraint of rTSA liners were observed between different implant systems, and in many cases even within the same implant systems. While the immediate clinical effect remains unclear, in theory the degree of constraint of the liner plays an important role for the dislocation and notching risk of a rTSA system. Cite this article: Bone Jt Open 2024;5(10):818–824


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 786 - 791
1 Jul 2022
Jenkinson MRJ Peeters W Hutt JRB Witt JD

Aims. Acetabular retroversion is a recognized cause of hip impingement and can be influenced by pelvic tilt (PT), which changes in different functional positions. Positional changes in PT have not previously been studied in patients with acetabular retroversion. Methods. Supine and standing anteroposterior (AP) pelvic radiographs were retrospectively analyzed in 69 patients treated for symptomatic acetabular retroversion. Measurements were made for acetabular index (AI), lateral centre-edge angle (LCEA), crossover index, ischial spine sign, and posterior wall sign. The change in the angle of PT was measured both by the sacro-femoral-pubic (SFP) angle and the pubic symphysis to sacroiliac (PS-SI) index. Results. In the supine position, the mean PT (by SFP) was 1.05° (SD 3.77°), which changed on standing to a PT of 8.64° (SD 5.34°). A significant increase in posterior PT from supine to standing of 7.59° (SD 4.5°; SFP angle) and 5.89° (SD 3.33°; PS-SI index) was calculated (p < 0.001). There was a good correlation in PT change between measurements using SFP angle and PS-SI index (0.901 in the preoperative group and 0.815 in the postoperative group). Signs of retroversion were significantly reduced in standing radiographs compared to supine: crossover index (0.16 (SD 0.16) vs 0.38 (SD 0.15); p < 0.001), crossover sign (19/28 hips vs 28/28 hips; p < 0.001), ischial spine sign (10/28 hips vs 26/28 hips; p < 0.001), and posterior wall sign (12/28 hips vs 24/28 hips; p < 0.001). Conclusion. Posterior PT increased from supine to standing in patients with symptomatic acetabular retroversion. The features of acetabular retroversion were less evident on standing radiographs. The low PT angle in the supine position is a factor in the increased appearance of acetabular retroversion. Patients presenting with symptoms of hip impingement should be assessed by supine and standing pelvic radiographs to highlight signs of acetabular retroversion, and to assist with optimizing acetabular correction at the time of surgery. Cite this article: Bone Joint J 2022;104-B(7):786–791



Bone & Joint Open
Vol. 4, Issue 7 | Pages 507 - 515
6 Jul 2023
Jørgensen PB Jakobsen SS Vainorius D Homilius M Hansen TB Stilling M

Aims. The Exeter short stem was designed for patients with Dorr type A femora and short-term results are promising. The aim of this study was to evaluate the minimum five-year stem migration pattern of Exeter short stems in comparison with Exeter standard stems. Methods. In this case-control study, 25 patients (22 female) at mean age of 78 years (70 to 89) received cemented Exeter short stem (case group). Cases were selected based on Dorr type A femora and matched first by Dorr type A and then age to a control cohort of 21 patients (11 female) at mean age of 74 years (70 to 89) who received with cemented Exeter standard stems (control group). Preoperatively, all patients had primary hip osteoarthritis and no osteoporosis as confirmed by dual X-ray absorptiometry scanning. Patients were followed with radiostereometry for evaluation of stem migration (primary endpoint), evaluation of cement quality, and Oxford Hip Score. Measurements were taken preoperatively, and at three, 12, and 24 months and a minimum five-year follow-up. Results. At three months, subsidence of the short stem -0.87 mm (95% confidence interval (CI) -1.07 to -0.67) was lower compared to the standard stem -1.59 mm (95% CI -1.82 to -1.36; p < 0.001). Both stems continued a similar pattern of subsidence until five-year follow-up. At five-year follow-up, the short stem had subsided mean -1.67 mm (95% CI -1.98 to -1.36) compared to mean -2.67 mm (95% CI -3.03 to -2.32) for the standard stem (p < 0.001). Subsidence was not influenced by preoperative bone quality (osteopenia vs normal) or cement mantle thickness. Conclusion. The standard Exeter stem had more early subsidence compared with the short Exeter stem in patients with Dorr type A femora, but thereafter a similar migration pattern of subsidence until minimum five years follow-up. Both the standard and the short Exeter stems subside. The standard stem subsides more compared to the short stem in Dorr type A femurs. Subsidence of the Exeter stems was not affected by cement mantle thickness. Cite this article: Bone Jt Open 2023;4(7):507–515


Bone & Joint Open
Vol. 2, Issue 12 | Pages 1089 - 1095
21 Dec 2021
Luo W Ali MS Limb R Cornforth C Perry DC

Aims. The Patient-Reported Outcomes Measurement Information System (PROMIS) has demonstrated faster administration, lower burden of data capture and reduced floor and ceiling effects compared to traditional Patient Reported Outcomes Measurements (PROMs). We investigated the suitability of PROMIS Mobility score in assessing physical function in the sequelae of childhood hip disease. Methods. In all, 266 adolscents (aged ≥ 12 years) and adults were identified with a prior diagnosis of childhood hip disease (either Perthes’ disease (n = 232 (87.2%)) or Slipped Capital Femoral Epiphysis (n = 34 (12.8%)) with a mean age of 27.73 years (SD 12.24). Participants completed the PROMIS Mobility Computer Adaptive Test, the Non-Arthritic Hip Score (NAHS), EuroQol five-dimension five-level questionnaire, and the Numeric Pain Rating Scale. We investigated the correlation between the PROMIS Mobility and other tools to assess use in this population and any clustering of outcome scores. Results. There was a strong correlation between the PROMIS Mobility and other established PROMs; NAHS (rs = 0.79; p < 0.001). There was notable clustering in PROMIS at the upper end of the distribution score (42.5%), with less seen in the NAHS (20.3%). However, the clustering was broadly similar between PROMIS Mobility and the comparable domains of the NAHS; function (53.6%), and activity (35.0%). Conclusion. PROMIS Mobility strongly correlated with other tools demonstrating convergent construct validity. There was clustering of physical function scores at the upper end of the distributions, which may reflect truncation of the data caused by participants having excellent outcomes. There were elements of disease not captured within PROMIS Mobility alone, and difficulties in differentiating those with the highest levels of function. Cite this article: Bone Jt Open 2021;2(12):1089–1095


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1112 - 1116
1 Aug 2018
Sinha R Weigl D Mercado E Becker T Kedem P Bar-On E

Aims. Guided growth using eight-plates is commonly used for correction of angular limb deformities in growing children. The principle is of tethering at the physeal periphery while enabling growth in the rest of the physis. The method is also applied for epiphysiodesis to correct limb-length discrepancy (LLD). Concerns have been raised regarding the potential of this method to create an epiphyseal deformity. However, this has not been investigated. The purpose of this study was to detect and quantify the occurrence of deformities in the proximal tibial epiphysis following treatment with eight-plates. Patients and Methods. A retrospective study was performed including 42 children at a mean age of 10.8 years (3.7 to 15.7) undergoing eight-plate insertion in the proximal tibia for correction of coronal plane deformities or LLD between 2007 and 2015. A total of 64 plates were inserted; 48 plates (34 patients) were inserted to correct angular deformities and 16 plates (8 patients) for LLD. Medical records, Picture Archive and Communication System images, and conventional radiographs were reviewed. Measurements included interscrew angle, lateral and medial plateau slope angles measured between the plateau surface and the line between the ends of the physis, and tibial plateau roof angle defined as 180° minus the sum of both plateau angles. Measurements were compared between radiographs performed adjacent to surgery and those at latest follow-up, and between operated and non-operated plateaus. Statistical analysis was performed using BMDP Statistical Software. Results. Slope angle increased in 31 (49.2%) of operated epiphyses by a mean of 5° (1° to 23°) compared with 29 (31.9%) in non-operated epiphyses (p = 0.043). Roof angle decreased in 29 (46.0%) of operated tibias and in 25 (27.5%) of non-operated ones by a mean of 5° (1° to 18°) (p = 0.028). Slope angle change frequency was similar in patients with LLD, varus and valgus correction (p = 0.37) but roof angle changes were slightly more frequent in LLD (p = 0.059) and correlated with the change in inter screw angles (r = 0.74, p = 0.001). Conclusion. The use of eight-plates in the proximal tibia for deformity correction and limb-length equalization causes a change in the bony morphology of the tibial plateau in a significant number of patients and the effect is more pronounced in the correction of LLD. Cite this article: Bone Joint J 2018;100-B:1112–16


The Bone & Joint Journal
Vol. 99-B, Issue 10 | Pages 1319 - 1328
1 Oct 2017
Shelton TJ Nedopil AJ Howell SM Hull ML

Aims. The aims of this study were to determine the proportion of patients with outlier varus or valgus alignment in kinematically aligned total knee arthroplasty (TKA), whether those with outlier varus or valgus alignment have higher forces in the medial or lateral compartments of the knee than those with in-range alignment and whether measurements of the alignment of the limb, knee and components predict compartment forces. Patients and Methods. The intra-operative forces in the medial and lateral compartments were measured with an instrumented tibial insert in 67 patients who underwent a kinematically aligned TKA during passive movement. The mean of the forces at full extension, 45° and 90° of flexion determined the force in the medial and lateral compartments. Measurements of the alignment of the limb and the components included the hip-knee-ankle (HKA) angle, proximal medial tibial angle (PMTA), and distal lateral femoral angle (DLFA). Measurements of the alignment of the knee and the components included the tibiofemoral angle (TFA), tibial component angle (TCA) and femoral component angle (FCA). Alignment was measured on post-operative, non-weight-bearing anteroposterior (AP) scanograms and categorised as varus or valgus outlier or in-range in relation to mechanically aligned criteria. Results. The proportion of patients with outlier varus or valgus alignment was 16%/24% for the HKA angle, 55%/0% for the PMTA, 0%/57% for the DLFA, 25%/12% for the TFA, 100%/0% for the TCA, and 0%/64% for the FCA. In general, the forces in the medial and lateral compartments of those with outlier alignment were not different from those with in-range alignment except for the TFA, in which patients with outlier varus alignment had a mean paradoxical force which was 6 lb higher in the lateral compartment than those with in-range alignment. None of the measurements of alignment of the limb, knee and components predicted the force in the medial or lateral compartment. Conclusion. Although kinematically aligned TKA has a high proportion of varus or valgus outliers using mechanically aligned criteria, the intra-operative forces in the medial and lateral compartments of patients with outlier alignment were comparable with those with in-range alignment, with no evidence of overload of the medial or lateral compartment of the knee. Cite this article: Bone Joint J 2017;99-B:1319–28


The Bone & Joint Journal
Vol. 99-B, Issue 8 | Pages 1109 - 1114
1 Aug 2017
Lang PJ Avoian T Sangiorgio SN Nazif MA Ebramzadeh E Zionts LE

Aims. After the initial correction of congenital talipes equinovarus (CTEV) using the Ponseti method, a subsequent dynamic deformity is often managed by transfer of the tendon of tibialis anterior (TATT) to the lateral cuneiform. Many surgeons believe the lateral cuneiform should be ossified before surgery is undertaken. This study quantifies the ossification process of the lateral cuneiform in children with CTEV between one and three years of age. . Patients and Methods. The length, width and height of the lateral cuneiform were measured in 43 consecutive patients with unilateral CTEV who had been treated using the Ponseti method. Measurements were taken by two independent observers on standardised anteroposterior and lateral radiographs of both feet taken at one, two and three years of age. Results. All dimensions of the lateral cuneiform on the affected side increased annually but remained smaller than the corresponding dimensions of the unaffected foot (p < 0.01). The lateral cuneiform resembled a 9 mm cube at two years and an 11 mm cube at three years. Conclusion. At one and two years, the ossification centre of the lateral cuneiform may not be large enough to accommodate a drill hole for tendon transfer. However, by three years, it has undergone sufficient ossification to do so. Cite this article: Bone Joint J 2017;99-B:1109–14


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 12 | Pages 1694 - 1699
1 Dec 2005
Floerkemeier T Hurschler C Witte F Wellmann M Thorey F Vogt U Windhagen H

The ability to predict load-bearing capacity during the consolidation phase in distraction osteogenesis by non-invasive means would represent a significant advance in the management of patients undergoing such treatment. Measurements of stiffness have been suggested as a promising tool for this purpose. Although the multidimensional characteristics of bone loading in compression, bending and torsion are apparent, most previous experiments have analysed only the relationship between maximum load-bearing capacity and a single type of stiffness. We have studied how compressive, bending and torsional stiffness are related to the torsional load-bearing capacity of healing callus using a common set of samples of bone regenerate from 26 sheep treated by tibial distraction osteogenesis. Our findings showed that measurements of torsional, bending and compressive stiffness were all suitable as predictors of the load-bearing capacity of healing callus. Measurements of torsional stiffness performed slightly better than those of compressive and bending stiffness


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 137 - 143
1 Jan 2020
Dias R Johnson NA Dias JJ

Aims. Carpal malalignment after a distal radial fracture occurs due to loss of volar tilt. Several studies have shown that this has an adverse influence on function. We aimed to investigate the magnitude of dorsal tilt that leads to carpal malalignment, whether reduction of dorsal tilt will correct carpal malalignment, and which measure of carpal malalignment is the most useful. Methods. Radiographs of patients with a distal radial fracture were prospectively collected and reviewed. Measurements of carpal malalignment were recorded on the initial radiograph, the radiograph following reduction of the fracture, and after a further interval. Linear regression modelling was used to assess the relationship between dorsal tilt and carpal malalignment. Receiver operating characteristic (ROC) analysis was used to identify which values of dorsal tilt led to carpal malalignment. Results. A total of 250 consecutive patients with 252 distal radial fractures were identified. All measures of carpal alignment were significantly associated with dorsal tilt at each timepoint. This relationship persisted after adjustment for age, sex, and the position of the wrist. Capitate shift consistently had the strongest relationship with dorsal tilt and was the only parameter that was not influenced by age or the position of the wrist. ROC curve analysis identified that abnormal capitate shift was seen with > 9° of dorsal tilt. Conclusion. Carpal malalignment is related to dorsal tilt following a distal radial fracture. Reducing the fracture and improving dorsal tilt will reduce carpal malalignment. Capitate shift is easy to assess visually, unrelated to age and sex, and appears to be the most useful measure of carpal malalignment. The aim during reduction of a distal radial fracture should be to realign the capitate with the axis of the radius and prevent carpal malalignment. Cite this article: Bone Joint J 2020;102-B(1):137–143


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 602 - 609
1 Jun 2023
Mistry D Ahmed U Aujla R Aslam N D’Alessandro P Malik S

Aims

In the UK, the agricultural, military, and construction sectors have stringent rules about the use of hearing protection due to the risk of noise-induced hearing loss. Orthopaedic staff may also be at risk due to the use of power tools. The UK Health and Safety Executive (HSE) have clear standards as to what are deemed acceptable occupational levels of noise on A-weighted and C-weighted scales. The aims of this review were to assess the current evidence on the testing of exposure to noise in orthopaedic operating theatres to see if it exceeds these regulations.

Methods

A search of PubMed and EMBASE databases was conducted using PRISMA guidelines. The review was registered prospectively in PROSPERO. Studies which assessed the exposure to noise for orthopaedic staff in operating theatres were included. Data about the exposure to noise were extracted from these studies and compared with the A-weighted and C-weighted acceptable levels described in the HSE regulations.


Bone & Joint Research
Vol. 7, Issue 9 | Pages 541 - 547
1 Sep 2018
Eijkenboom JFA Waarsing JH Oei EHG Bierma-Zeinstra SMA van Middelkoop M

Objectives. It has been hypothesized that patellofemoral pain, a common knee condition in adolescents and young adults, may be a precursor of degenerative joint changes and may ultimately lead to patellofemoral osteoarthritis. Since both conditions share several mechanical disease characteristics, such as altered contact area between the femur and patella and increased joint stress, we investigated whether these conditions share similar and different shape characteristics of the patella compared with normal controls. Methods. This cross-sectional study compared three different study populations: 32 patellofemoral pain subjects (mean age, 32 years (22 to 45); 72% female); 56 isolated radiological patellofemoral osteoarthritis subjects (mean age, 54 years (44 to 58); 89% female); and 80 healthy control subjects (mean age, 52 years (44 to 58); 74% female). Measurements included questionnaires, and lateral and skyline radiographs of the knee. Two separate 30-point 2D statistical shape models of the patella were created from the lateral and skyline radiographs. A general linear model was used to test for differences in standardized shape modes (a specific shape variant of the patella) between patellofemoral osteoarthritis, patellofemoral pain, and controls, using Bonferroni correction and adjustment for body mass index and gender. Results. Five shape modes showed statistically significant differences between groups: skyline modes 1 (p < 0.001), 8 (p = 0.004), and 10 (p < 0.001); and lateral modes 5 (p = 0.002) and 7 (p = 0.002). Skyline mode 8 and lateral mode 5 were similar for patellofemoral osteoarthritis and patellofemoral pain populations, while being statistically significant different from the control group. Conclusion. Our results indicate that patellofemoral pain and patellofemoral osteoarthritis share similar shape characteristics, which are different from control subjects. These findings support the proposed continuum disease model of patellofemoral pain predisposing to the development of patellofemoral osteoarthritis. Cite this article: J. F. A. Eijkenboom, J. H. Waarsing, E. H. G. Oei, S. M. A. Bierma-Zeinstra, M. van Middelkoop. Is patellofemoral pain a precursor to osteoarthritis? Patellofemoral osteoarthritis and patellofemoral pain patients share aberrant patellar shape compared with healthy controls. Bone Joint Res 2018;7:541–547. DOI: 10.1302/2046-3758.79.BJR-2018-0112.R1


Bone & Joint Open
Vol. 4, Issue 11 | Pages 825 - 831
1 Nov 2023
Joseph PJS Khattak M Masudi ST Minta L Perry DC

Aims

Hip disease is common in children with cerebral palsy (CP) and can decrease quality of life and function. Surveillance programmes exist to improve outcomes by treating hip disease at an early stage using radiological surveillance. However, studies and surveillance programmes report different radiological outcomes, making it difficult to compare. We aimed to identify the most important radiological measurements and develop a core measurement set (CMS) for clinical practice, research, and surveillance programmes.

Methods

A systematic review identified a list of measurements previously used in studies reporting radiological hip outcomes in children with CP. These measurements informed a two-round Delphi study, conducted among orthopaedic surgeons and specialist physiotherapists. Participants rated each measurement on a nine-point Likert scale (‘not important’ to ‘critically important’). A consensus meeting was held to finalize the CMS.