Advertisement for orthosearch.org.uk
Results 1 - 9 of 9
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1257 - 1262
1 Nov 2024
Nowak LL Moktar J Henry P Dejong T McKee MD Schemitsch EH

Aims

We aimed to compare reoperations following distal radial fractures (DRFs) managed with early fixation versus delayed fixation following initial closed reduction (CR).

Methods

We used administrative databases in Ontario, Canada, to identify DRF patients aged 18 years or older from 2003 to 2016. We used procedural and fee codes within 30 days to determine which patients underwent early fixation (≤ seven days) or delayed fixation following CR. We grouped patients in the delayed group by their time to definitive fixation (eight to 14 days, 15 to 21 days, and 22 to 30 days). We used intervention and diagnostic codes to identify reoperations within two years. We used multivariable regression to compare the association between early versus delayed fixation and reoperation for all patients and stratified by age (18 to 60 years and > 60 years).


Bone & Joint Open
Vol. 2, Issue 11 | Pages 981 - 987
25 Nov 2021
Feitz R Khoshnaw S van der Oest MJW Souer JS Slijper HP Hovius SER Selles RW

Aims

Studies on long-term patient-reported outcomes after open surgery for triangular fibrocartilage complex (TFCC) are scarce. Surgeons and patients would benefit from self-reported outcome data on pain, function, complications, and satisfaction after this surgery to enhance shared decision-making. The aim of this study is to determine the long-term outcome of adults who had open surgery for the TFCC.

Methods

A prospective cohort study that included patients with open surgery for the TFCC between December 2011 and September 2015. In September 2020, we sent these patients an additional follow-up questionnaire, including the Patient-Rated Wrist Evaluation (PRWE), to score satisfaction, complications, pain, and function.


Bone & Joint Open
Vol. 2, Issue 3 | Pages 141 - 149
1 Mar 2021
Saab M Chick G

Aims

The objective of this systematic review was to describe trapeziectomy outcomes and complications in the context of osteoarthritis of the base of the thumb after a five-year minimum follow-up.

Methods

Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were used to guide study design, and 267 full-text articles were assessed for eligibility. After exclusion criteria application, 22 studies were included, involving 728 patients and 823 trapeziectomies. Outcomes included pre- and postoperative clinical and radiological characteristics. Complications and revisions were recorded.


Bone & Joint Open
Vol. 1, Issue 10 | Pages 639 - 643
12 Oct 2020
Atia F Pocnetz S Selby A Russell P Bainbridge C Johnson N

Aims

The aim of this study was to evaluate the need for hand trauma services during the COVID-19 pandemic lockdown, specifically related to surgical requirements. This will provide useful information for planning and resource allocation in the event of any further lockdown.

Methods

A prospective analsysis of all patients attending our hand trauma unit throughout the UK COVID-19 lockdown period (24 March to 10 May 2020) was carried out. Prospectively collected departmental data from the same period in 2019 was obtained and reviewed for comparison. The number of patients attending clinic, undergoing surgery, the type of surgical procedure, and rate of surgery was compared.


Aims

To assess the proportion of patients with distal radius fractures (DRFs) who were managed nonoperatively during the COVID-19 pandemic in accordance with the British Orthopaedic Association BOAST COVID-19 guidelines, who would have otherwise been considered for an operative intervention.

Methods

We retrospectively reviewed the radiographs and clinical notes of all patients with DRFs managed nonoperatively, following the publication of the BOAST COVID-19 guidelines on the management of urgent trauma between 26 March and 18 May 2020. Radiological parameters including radial height, radial inclination, intra-articular step-off, and volar tilt from post-reduction or post-application of cast radiographs were measured. The assumption was that if one radiological parameter exceeds the acceptable criteria, the patient would have been considered for an operative intervention in pre-COVID times.


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 137 - 143
1 Jan 2020
Dias R Johnson NA Dias JJ

Aims

Carpal malalignment after a distal radial fracture occurs due to loss of volar tilt. Several studies have shown that this has an adverse influence on function. We aimed to investigate the magnitude of dorsal tilt that leads to carpal malalignment, whether reduction of dorsal tilt will correct carpal malalignment, and which measure of carpal malalignment is the most useful.

Methods

Radiographs of patients with a distal radial fracture were prospectively collected and reviewed. Measurements of carpal malalignment were recorded on the initial radiograph, the radiograph following reduction of the fracture, and after a further interval. Linear regression modelling was used to assess the relationship between dorsal tilt and carpal malalignment. Receiver operating characteristic (ROC) analysis was used to identify which values of dorsal tilt led to carpal malalignment.


The Bone & Joint Journal
Vol. 99-B, Issue 3 | Pages 369 - 375
1 Mar 2017
Ross M Wiemann M Peters SE Benson R Couzens GB

Aims

The aims of this study were: firstly, to investigate the influence of the thickness of cartilage at the sigmoid notch on the inclination of the distal radioulnar joint (DRUJ), and secondly, to compare the sensitivity and specificity of MRI with plain radiographs for the assessment of the inclination of the articular surface of the DRUJ in the coronal plane.

Patients and Methods

Contemporaneous MRI images and radiographs of 100 wrists from 98 asymptomatic patients (mean age 43 years, (16 to 67); 52 male, 53%) with no history of a fracture involving the wrist or surgery to the wrist, were reviewed. The thickness of the cartilage at the sigmoid notch, inclination of the DRUJ and Tolat Type of each DRUJ were determined.


The Bone & Joint Journal
Vol. 99-B, Issue 1 | Pages 100 - 106
1 Jan 2017
Aujla RS Sheikh N Divall P Bhowal B Dias JJ

Aims

We performed a systematic review of the current literature regarding the outcomes of unconstrained metacarpophalangeal joint (MCPJ) arthroplasty.

Materials and Methods

We initially identified 1305 studies, and 406 were found to be duplicates. After exclusion criteria were applied, seven studies were included. Outcomes extracted included pre- and post-operative pain visual analogue scores, range of movement (ROM), strength of pinch and grip, satisfaction and patient reported outcome measures (PROMs). Clinical and radiological complications were recorded. The results are presented in three groups based on the design of the arthroplasty and the aetiology (pyrocarbon-osteoarthritis (pyro-OA), pyrocarbon-inflammatory arthritis (pyro-IA), metal-on-polyethylene (MoP)).


The Bone & Joint Journal
Vol. 99-B, Issue 2 | Pages 237 - 244
1 Feb 2017
Vegt AEVD Grond R Grüschke JS Boomsma MF Emmelot CH Dijkstra PU Sluis CKVD

Aims

The aim of this study was to compare the Push Ortho Thumb Brace CMC and a custom-made orthosis in the treatment of patients with primary osteoarthritis of the carpometacarpal joint of the thumb. Our outcome measures were pain scores, tests of hand function, patient satisfaction and patient preference.

Patients and Methods

A multicentre crossover randomised controlled trial was conducted which included 63 patients (44 women) with primary osteoarthritis of the carpometacarpal joint of the thumb. Of these, 59 patients with a mean age of 60.1 years (standard deviation 8.2), completed the study. Patients used both orthoses for two weeks with a two-week washout period in-between. Pain was measured on a 10-cm visual analogue scale. Hand function was assessed using the Jebsen Taylor Hand Function test, Nine Hole Peg Test, key grip, pinch grip and Functional Index for Hand Osteoarthritis. Patient preference was assessed using the Dutch version of the Quebec User Evaluation of Satisfaction with Assistive Technology score.