Advertisement for orthosearch.org.uk
Results 1 - 20 of 441
Results per page:
The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 864 - 871
1 Aug 2023
Tyas B Marsh M de Steiger R Lorimer M Petheram TG Inman DS Reed MR Jameson SS

Aims. Several different designs of hemiarthroplasty are used to treat intracapsular fractures of the proximal femur, with large variations in costs. No clinical benefit of modular over monoblock designs has been reported in the literature. Long-term data are lacking. The aim of this study was to report the ten-year implant survival of commonly used designs of hemiarthroplasty. Methods. Patients recorded by the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) between 1 September 1999 and 31 December 2020 who underwent hemiarthroplasty for the treatment of a hip fracture with the following implants were included: a cemented monoblock Exeter Trauma Stem (ETS), cemented Exeter V40 with a bipolar head, a monoblock Thompsons prosthesis (Cobalt/Chromium or Titanium), and an Exeter V40 with a Unitrax head. Overall and age-defined cumulative revision rates were compared over the ten years following surgery. Results. A total of 41,949 hemiarthroplasties were included. Exeter V40 with a Unitrax head was the most commonly used (n = 20,707, 49.4%). The overall rate of revision was small. A total of 28,201 patients (67.2%) were aged > 80 years. There were no significant differences in revision rates across all designs of hemiarthroplasty in patients of this age at any time. The revision rates for all designs were < 3.5%, three years postoperatively. At subsequent times the ETS and Exeter V40 with a bipolar head performed well in all age groups. The unadjusted ten-year mortality rate for the whole cohort was 82.2%. Conclusion. There was no difference in implant survival between all the designs of hemiarthroplasty in the first three years following surgery, supporting the selection of a cost-effective design of hemiarthroplasty for most patients with an intracapsular fracture of the hip, as determined by local availability and costs. Beyond this, the ETS and Exeter bipolar designs performed well in all age groups. Cite this article: Bone Joint J 2023;105-B(8):864–871


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 689 - 695
1 Apr 2021
Jämsä P Reito A Oksala N Eskelinen A Jämsen E

Aims

To investigate whether chronic kidney disease (CKD) is associated with the risk of all-cause revision or revision due to a periprosthetic joint infection (PJI) after primary hip or knee arthroplasty.

Methods

This retrospective cohort study comprised 18,979 consecutive hip and knee arthroplasties from a single high-volume academic hospital. At a median of 5.6 years (interquartile range (IQR) 3.5 to 8.1), all deaths and revisions were counted. To overcome the competing risk of death, competing risk analysis using the cumulative incidence function (CIF) was applied to analyze the association between different stages of CKD and revisions. Confounding factors such as diabetes and BMI were considered using either a stratified CIF or the Fine and Gray model.


Bone & Joint Open
Vol. 4, Issue 2 | Pages 110 - 119
21 Feb 2023
Macken AA Prkić A van Oost I Spekenbrink-Spooren A The B Eygendaal D

Aims. The aim of this study is to report the implant survival and factors associated with revision of total elbow arthroplasty (TEA) using data from the Dutch national registry. Methods. All TEAs recorded in the Dutch national registry between 2014 and 2020 were included. The Kaplan-Meier method was used for survival analysis, and a logistic regression model was used to assess the factors associated with revision. Results. A total of 514 TEAs were included, of which 35 were revised. The five-year implant survival was 91%. Male sex, a higher BMI, and previous surgery to the same elbow showed a statistically significant association with revision (p < 0.036). Of the 35 revised implants, ten (29%) underwent a second revision. Conclusion. This study reports a five-year implant survival of TEA of 91%. Patient factors associated with revision are defined and can be used to optimize informed consent and shared decision-making. There was a high rate of secondary revisions. Cite this article: Bone Jt Open 2023;4(2):110–119


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 198 - 204
1 Feb 2020
Perlbach R Palm L Mohaddes M Ivarsson I Schilcher J

Aims. This single-centre observational study aimed to describe the results of extensive bone impaction grafting of the whole acetabular cavity in combination with an uncemented component in acetabular revisions performed in a standardized manner since 1993. Methods. Between 1993 and 2013, 370 patients with a median age of 72 years (interquartile range (IQR) 63 to 79 years) underwent acetabular revision surgery. Of these, 229 were more than ten years following surgery and 137 were more than 15 years. All revisions were performed with extensive use of morcellized allograft firmly impacted into the entire acetabular cavity, followed by insertion of an uncemented component with supplementary screw fixation. All types of reoperation were captured using review of radiographs and medical charts, combined with data from the local surgical register and the Swedish Hip Arthroplasty Register. Results. Among patients with possible follow-up of ten and 15 years, 152 and 72 patients remained alive without revision of the acetabular component. The number of deaths was 61 and 50, respectively. Of those who died, six patients in each group had a reoperation performed before death. The number of patients with a reoperation was 22 for those with ten-year follow-up and 21 for those with 15 years of follow-up. The Kaplan-Meier implant survival rate for aseptic loosening among all 370 patients in the cohort was 96.3% (95% confidence interval (CI) 94.1 to 98.5) after ten years and 92.8% (95% CI 89.2 to 96.6) after 15 years. Conclusion. Extensive bone impaction grafting combined with uncemented revision components appears to be a reliable method with favourable long-term survival. This technique offers the advantage of bone stock restoration and disputes the long-standing perception that uncemented components require > 50% of host bone contact for successful implant survival. Cite this article: Bone Joint J 2020;102-B(2):198–204


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1199 - 1208
1 Oct 2019
Lamb JN Matharu GS Redmond A Judge A West RM Pandit HG

Aims

We compared implant and patient survival following intraoperative periprosthetic femoral fractures (IOPFFs) during primary total hip arthroplasty (THA) with matched controls.

Patients and Methods

This retrospective cohort study compared 4831 hips with IOPFF and 48 154 propensity score matched primary THAs without IOPFF implanted between 2004 and 2016, which had been recorded on a national joint registry. Implant and patient survival rates were compared between groups using Cox regression.


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 808 - 816
1 Aug 2024
Hall AJ Cullinan R Alozie G Chopra S Greig L Clarke J Riches PE Walmsley P Ohly NE Holloway N

Aims. Total knee arthroplasty (TKA) with a highly congruent condylar-stabilized (CS) articulation may be advantageous due to increased stability versus cruciate-retaining (CR) designs, while mitigating the limitations of a posterior-stabilized construct. The aim was to assess ten-year implant survival and functional outcomes of a cemented single-radius TKA with a CS insert, performed without posterior cruciate ligament sacrifice. Methods. This retrospective cohort study included consecutive patients undergoing TKA at a specialist centre in the UK between November 2010 and December 2012. Data were collected using a bespoke electronic database and cross-referenced with national arthroplasty audit data, with variables including: preoperative characteristics, intraoperative factors, complications, and mortality status. Patient-reported outcome measures (PROMs) were collected by a specialist research team at ten years post-surgery. There were 536 TKAs, of which 308/536 (57.5%) were in female patients. The mean age was 69.0 years (95% CI 45.0 to 88.0), the mean BMI was 32.2 kg/m. 2. (95% CI 18.9 to 50.2), and 387/536 (72.2%) survived to ten years. There were four revisions (0.7%): two deep infections (requiring debridement and implant retention), one aseptic loosening, and one haemosiderosis. Results. Kaplan-Meier analysis demonstrated no difference in implant survival according to sex, age, or obesity status. Ten-year PROMs were available for 196/387 (50.6%) surviving patients and were excellent: mean Oxford Knee Score 34.4 (95% CI 32.7 to 36.1); mean Forgotten Joint Score (FJS) 51.2 (95% CI 16.1 to 86.3); mean EuroQol five-dimension five-level questionnaire score 69.9 (95% CI 46.8 to 93.0); 141/196 (71.9%) achieved the 22-point FJS patient-acceptable symptom state (PASS); and 156/196 (79.6%) were “very satisfied or satisfied”. Conclusion. This is the only large study reporting ten-year implant survival and functional outcomes of TKA using a cemented single-radius design and with a CS tibial bearing construct. The findings of excellent implant survival, safety, and functional outcomes indicate that this combination is a safe and effective option in routine TKA. Further investigation of this single-radius design TKA with CS tibial bearings with well-matched patient study groups will allow further insight into the performance of these implants. Cite this article: Bone Joint J 2024;106-B(8):808–816


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1121 - 1126
1 Aug 2013
Núñez-Pereira S Pellisé F Rodríguez-Pardo D Pigrau C Bagó J Villanueva C Cáceres E

This study evaluates the long-term survival of spinal implants after surgical site infection (SSI) and the risk factors associated with treatment failure. . A Kaplan-Meier survival analysis was carried out on 43 patients who had undergone a posterior spinal fusion with instrumentation between January 2006 and December 2008, and who consecutively developed an acute deep surgical site infection. All were appropriately treated by surgical debridement with a tailored antibiotic program based on culture results for a minimum of eight weeks. A ‘terminal event’ or failure of treatment was defined as implant removal or death related to the SSI. The mean follow-up was 26 months (1.03 to 50.9). A total of ten patients (23.3%) had a terminal event. The rate of survival after the first debridement was 90.7% (95% confidence interval (CI) 82.95 to 98.24) at six months, 85.4% (95% CI 74.64 to 96.18) at one year, and 73.2% (95% CI 58.70 to 87.78) at two, three and four years. Four of nine patients required re-instrumentation after implant removal, and two of the four had a recurrent infection at the surgical site. There was one recurrence after implant removal without re-instrumentation. Multivariate analysis revealed a significant risk of treatment failure in patients who developed sepsis (hazard ratio (HR) 12.5 (95% confidence interval (CI) 2.6 to 59.9); p < 0.001) or who had > three fused segments (HR 4.5 (95% CI 1.25 to 24.05); p = 0.03). Implant survival is seriously compromised even after properly treated surgical site infection, but progressively decreases over the first 24 months. Cite this article: Bone Joint J 2013;95-B:1121–6


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1557 - 1566
1 Nov 2012
Jameson SS Kyle J Baker PN Mason J Deehan DJ McMurtry IA Reed MR

United Kingdom National Institute for Health and Clinical Excellence guidelines recommend the use of total hip replacement (THR) for displaced intracapsular fractures of the femoral neck in cognitively intact patients, who were independently mobile prior to the injury. This study aimed to analyse the risk factors associated with revision of the implant and mortality following THR, and to quantify risk. National Joint Registry data recording a THR performed for acute fracture of the femoral neck between 2003 and 2010 were analysed. Cox proportional hazards models were used to investigate the extent to which risk of revision was related to specific covariates. Multivariable logistic regression was used to analyse factors affecting peri-operative mortality (< 90 days). A total of 4323 procedures were studied. There were 80 patients who had undergone revision surgery at the time of censoring (five-year revision rate 3.25%, 95% confidence interval 2.44 to 4.07) and 137 patients (3.2%) patients died within 90 days. After adjusting for patient and surgeon characteristics, an increased risk of revision was associated with the use of cementless prostheses compared with cemented (hazard ratio (HR) 1.33, p = 0.021). Revision was independent of bearing surface and head size. The risk of mortality within 90 days was significantly increased with higher American Society of Anesthesiologists (ASA) grade (grade 3: odds ratio (OR) 4.04, p < 0.001; grade 4/5: OR 20.26, p < 0.001; both compared with grades 1/2) and older age (≥ 75 years: OR 1.65, p = 0.025), but reduced over the study period (9% relative risk reduction per year).

THR is a good option in patients aged < 75 years and with ASA 1/2. Cementation of the femoral component does not adversely affect peri-operative mortality but improves survival of the implant in the mid-term when compared with cementless femoral components. There are no benefits of using head sizes > 28 mm or bearings other than metal-on-polyethylene. More research is required to determine the benefits of THR over hemiarthroplasty in older patients and those with ASA grades > 2.


The Bone & Joint Journal
Vol. 98-B, Issue 1 | Pages 33 - 39
1 Jan 2016
Sabah SA Henckel J Koutsouris S Rajani R Hothi H Skinner JA Hart AJ

Aims

The National Joint Registry for England, Wales and Northern Ireland (NJR) has extended its scope to report on hospital, surgeon and implant performance. Data linkage of the NJR to the London Implant Retrieval Centre (LIRC) has previously evaluated data quality for hip primary procedures, but did not assess revision records.

Methods

We analysed metal-on-metal hip revision procedures performed between 2003 and 2013. A total of 69 929 revision procedures from the NJR and 929 revised pairs of components from the LIRC were included.


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1640 - 1646
1 Dec 2018
Medellin MR Fujiwara T Clark R Jeys LM

Aims. The aim of this study was to describe, analyze, and compare the survival, functional outcome, and complications of minimally invasive (MI) and non-invasive (NI) lengthening total femoral prostheses. Patients and Methods. A total of 24 lengthening total femoral prostheses, 11 MI and 13 NI, were implanted between 1991 and 2016. The characteristics, complications, and functional results were recorded. There were ten female patients and ten male patients. Their mean age at the time of surgery was 11 years (2 to 41). The mean follow-up was 13.2 years (seven months to 29.25 years). A survival analysis was performed, and the failures were classified according to the Modified Henderson System. Results. The overall implant survival was 79% at five, ten, and 20 years for MI prostheses, and 84% at five years and 70% at ten years for NI prostheses. At the final follow-up, 13 prostheses did not require further surgery. The overall complication rate was 46%. The mean revision-free implant survival for MI and NI prostheses was 59 months and 49 months, respectively. There were no statistically significant differences in the overall implant survival, revision-free survival, or the distribution of complications between the two types of prosthesis. Infection rates were also comparable in the groups (9% vs 7%; p = 0.902). The rate of leg-length discrepancy was 54% in MI prostheses and 23% in NI prostheses. In those with a MI prosthesis, there was a smaller mean range of movement of the knee (0° to 62° vs 0° to 83°; p = 0.047), the flexion contracture took a longer mean time to resolve after lengthening (3.3 months vs 1.07 months; p < 0.001) and there was a lower mean Musculoskeletal Tumor Society (MSTS) score (24.7 vs 27; p = 0.295). Conclusion. The survival and complications of MI and NI lengthening total femoral prostheses are comparable. However, patients with NI prosthesis have more accurate correction of leg-length discrepancy, a better range of movement of the knee and an improved overall function


The Bone & Joint Journal
Vol. 103-B, Issue 9 | Pages 1449 - 1456
1 Sep 2021
Kazarian GS Lieberman EG Hansen EJ Nunley RM Barrack RL

Aims. The goal of the current systematic review was to assess the impact of implant placement accuracy on outcomes following total knee arthroplasty (TKA). Methods. A systematic review was performed in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines using the Ovid Medline, Embase, Cochrane Central, and Web of Science databases in order to assess the impact of the patient-reported outcomes measures (PROMs) and implant placement accuracy on outcomes following TKA. Studies assessing the impact of implant alignment, rotation, size, overhang, or condylar offset were included. Study quality was assessed, evidence was graded (one-star: no evidence, two-star: limited evidence, three-star: moderate evidence, four-star: strong evidence), and recommendations were made based on the available evidence. Results. A total of 49 studies were identified for inclusion. With respect to PROMs, there was two-star evidence in support of mechanical axis alignment (MAA), femorotibial angle (FTA), femoral coronal angle (FCA), tibial coronal angle (TCA), femoral sagittal angle (FSA), femoral rotation, tibial and combined rotation/mismatch, and implant size/overhang or offset on PROMs, and one-star evidence in support of tibial sagittal angle (TSA), impacting PROMs. With respect to survival, there was three- to four-star evidence in support FTA, FCA, TCA, and TSA, moderate evidence in support of femoral rotation, tibial and combined rotation/mismatch, and limited evidence in support of MAA, FSA, and implant size/overhang or offset impacting survival. Conclusion. Overall, there is limited evidence to suggest that PROMs are impacted by the accuracy of implant placement, and malalignment does not appear to be a significant driver of the observed high rates of patient dissatisfaction following TKA. However, FTA, FCA, TCA, TSA, and implant rotation demonstrate a moderate-strong relationship with implant survival. Efforts should be made to improve the accuracy of these parameters in order to improve TKA survival. Cite this article: Bone Joint J 2021;103-B(9):1449–1456


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 632 - 639
1 May 2017
Hamilton TW Pandit HG Maurer DG Ostlere SJ Jenkins C Mellon SJ Dodd CAF Murray DW

Aims. It is not clear whether anterior knee pain and osteoarthritis (OA) of the patellofemoral joint (PFJ) are contraindications to medial unicompartmental knee arthroplasty (UKA). Our aim was to investigate the long-term outcome of a consecutive series of patients, some of whom had anterior knee pain and PFJ OA managed with UKA. Patients and Methods. We assessed the ten-year functional outcomes and 15-year implant survival of 805 knees (677 patients) following medial mobile-bearing UKA. The intra-operative status of the PFJ was documented and, with the exception of bone loss with grooving to the lateral side, neither the clinical or radiological state of the PFJ nor the presence of anterior knee pain were considered a contraindication. The impact of radiographic findings and anterior knee pain was studied in a subgroup of 100 knees (91 patients). Results. There was no relationship between functional outcomes, at a mean of ten years, or 15-year implant survival, and pre-operative anterior knee pain, or the presence or degree of cartilage loss documented intra-operatively at the medial patella or trochlea, or radiographic evidence of OA in the medial side of the PFJ. In 6% of cases there was full thickness cartilage loss on the lateral side of the patella. In these cases, the overall ten-year function and 15-year survival was similar to those without cartilage loss; however they had slightly more difficulty with descending stairs. Radiographic signs of OA seen in the lateral part of the PFJ were not associated with a definite compromise in functional outcome or implant survival. Conclusion. Severe damage to the lateral side of the PFJ with bone loss and grooving remains a contraindication to mobile-bearing UKA. Less severe damage to the lateral side of the PFJ and damage to the medial side, however severe, does not compromise the overall function or survival, so should not be considered to be a contraindication. However, if a patient does have full thickness cartilage loss on the lateral side of the PFJ they may have a slight compromise in their ability to descend stairs. Pre-operative anterior knee pain also does not compromise the functional outcome or survival and should not be considered to be a contraindication. Cite this article: Bone Joint J 2017;99-B:632–9


The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 475 - 482
1 Apr 2017
Hamilton TW Pandit HG Inabathula A Ostlere SJ Jenkins C Mellon SJ Dodd CAF Murray DW

Aims. While medial unicompartmental knee arthroplasty (UKA) is indicated for patients with full-thickness cartilage loss, it is occasionally used to treat those with partial-thickness loss. The aim of this study was to investigate the five-year outcomes in a consecutive series of UKAs used in patients with partial thickness cartilage loss in the medial compartment of the knee. Patients and Methods. Between 2002 and 2014, 94 consecutive UKAs were undertaken in 90 patients with partial thickness cartilage loss and followed up independently for a mean of six years (1 to 13). These patients had partial thickness cartilage loss either on both femur and tibia (13 knees), or on either the femur or the tibia, with full thickness loss on the other surface of the joint (18 and 63 knees respectively). Using propensity score analysis, these patients were matched 1:2 based on age, gender and pre-operative Oxford Knee Score (OKS) with knees with full thickness loss on both the femur and tibia. The functional outcomes, implant survival and incidence of re-operations were assessed at one, two and five years post-operatively. A subgroup of 36 knees in 36 patients with partial thickness cartilage loss, who had pre-operative MRI scans, was assessed to identify whether there were any factors identified on MRI that predicted the outcome. Results. Knees with partial thickness cartilage loss had significantly worse functional outcomes at one, two and five years post-operatively compared with those with full thickness loss. A quarter of knees with partial thickness loss had a fair or poor result and a fifth failed to achieve a clinically significant improvement in OKS from a baseline of four points or more; double that seen in knees with full thickness loss. Whilst there was no difference in implant survival between the groups, the rate of re-operation in knees with partial thickness loss was three times higher. Most of the re-operations (three-quarters), were arthroscopies for persistent pain. Compared with those achieving good or excellent outcomes, patients with partial thickness cartilage loss who achieved fair or poor outcomes were younger and had worse pre-operative functional scores. However, there were no other differences in the baseline demographics. MRI findings of full thickness cartilage loss, subchondral oedema, synovitis or effusion did not provide additional prognostic information. Conclusion. Medial UKA should be reserved for patients with full thickness cartilage loss on both the femur and tibia. Whilst some patients with partial thickness loss achieve a good result we cannot currently identify which these will be and in this situation MRI is unhelpful and misleading. Cite this article: Bone Joint J 2017;99-B:475–82


Bone & Joint Research
Vol. 8, Issue 10 | Pages 443 - 450
1 Oct 2019
Treacy RBC Holland JP Daniel J Ziaee H McMinn DJW

Objectives. Modern metal-on-metal (MoM) hip resurfacing arthroplasty (HRA), while achieving good results with well-orientated, well-designed components in ideal patients, is contraindicated in women, men with head size under 50 mm, or metal hypersensitivity. These patients currently have no access to the benefits of HRA. Highly crosslinked polyethylene (XLPE) has demonstrated clinical success in total hip arthroplasty (THA) and, when used in HRA, potentially reduces metal ion-related sequelae. We report the early performance of HRA using a direct-to-bone cementless mono-bloc XLPE component coupled with a cobalt-chrome femoral head, in the patient group for whom HRA is currently contraindicated. Methods. This is a cross-sectional, observational assessment of 88 consecutive metal-on-XLPE HRAs performed in 84 patients between 2015 and 2018 in three centres (three surgeons, including the designer surgeon). Mean follow-up is 1.6 years (0.7 to 3.9). Mean age at operation was 56 years (. sd. 11; 21 to 82), and 73% of implantations were in female patients. All patients were individually counselled, and a detailed informed consent was obtained prior to operation. Primary resurfacing was carried out in 85 hips, and three cases involved revision of previous MoM HRA. Clinical, radiological, and Oxford Hip Score (OHS) assessments were studied, along with implant survival. Results. There was no loss to follow-up and no actual or impending revision or reoperation. Median OHS increased from 24 (interquartile range (IQR) 20 to 28) preoperatively to 48 (IQR 46 to 48) at the latest follow-up (48 being the best possible score). Radiographs showed one patient had a head-neck junction lucency. No other radiolucency, osteolysis, component migration, or femoral neck thinning was noted. Conclusion. The results in this small consecutive cohort suggest that metal-on-monobloc-XLPE HRA is successful in the short term and merits further investigation as a conservative alternative to the current accepted standard of stemmed THA. However, we would stress that survival data with longer-term follow-up are needed prior to widespread adoption. Cite this article: R. B. C. Treacy, J. P. Holland, J. Daniel, H. Ziaee, D. J. W. McMinn. Preliminary report of clinical experience with metal-on-highly-crosslinked-polyethylene hip resurfacing. Bone Joint Res 2019;8:443–450. DOI: 10.1302/2046-3758.810.BJR-2019-0060.R1


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 47 - 54
1 Jan 2019
Clough T Bodo K Majeed H Davenport J Karski M

Aims. We report the long-term clinical and radiological outcomes of a consecutive series of 200 total ankle arthroplasties (TAAs, 184 patients) at a single centre using the Scandinavian Total Ankle Replacement (STAR) implants. Patients and Methods. Between November 1993 and February 2000, 200 consecutive STAR prostheses were implanted in 184 patients by a single surgeon. Demographic and clinical data were collected prospectively and the last available status was recorded for further survival analysis. All surviving patients underwent regular clinical and radiological review. Pain and function were assessed using the American Orthopaedic Foot and Ankle Society (AOFAS) hindfoot scoring system. The principal endpoint of the study was failure of the implant requiring revision of one or all of the components. Kaplan–Meier survival curves were generated with 95% confidence intervals and the rate of failure calculated for each year. Results. A total of 84 patients (87 ankles) were alive by the end of this study. Of the surviving 84 patients (87 ankles; rheumatoid arthritis (RA), n = 40; OA, n = 47), 45 were women and 39 were men, with a mean age of 54 years (18 to 72 years) at the time of surgery. A total of 32 implants failed (16%), requiring revision surgery. The mean time to revision was 80 months (2 to 257). The implant survival at 15.8 years, using revision as an endpoint, was 76.16% (95% confidence interval (CI) 64.41 to 87.91). We found a steady but low decrease in survival over the study period. The mean AOFAS score improved from 28 (10 to 52) preoperatively to 61 (20 to 90) at long-term follow-up. Conclusion. STAR prostheses in the United Kingdom have now been largely superseded by newer design TAAs, potentially with improved characteristics and surgical techniques. The long-term survivorship for the STAR prosthesis can provide a benchmark for these later designs of ankle arthroplasty


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 522 - 528
1 May 2019
Medellin MR Fujiwara T Clark R Stevenson JD Parry M Jeys L

Aims. The aim of this study was to evaluate the prosthesis characteristics and associated conditions that may modify the survival of total femoral endoprosthetic replacements (TFEPR). Patients and Methods. In all, 81 patients treated with TFEPR from 1976 to 2017 were retrospectively evaluated and failures were categorized according to the Henderson classification. There were 38 female patients (47%) and 43 male patients (53%) with a mean age at diagnosis of 43 years (12 to 86). The mean follow-up time was 10.3 years (0 to 31.7). A survival analysis was performed followed by univariate and multivariate Cox regression to identify independent implant survival factors. Results. The revision-free survival of the implant was 71% at five years and 63.3% at ten years. Three prostheses reached 15 years without revision. The mean Musculoskeletal Tumor Society score in the group was 26 (23 to 28). The mechanisms of failure were infection in 18%, structural failures in 6%, tumour progression in 5%, aseptic loosening in 2%, and soft-tissue failures in 1%. Prostheses used for primary reconstruction after oncological resections had lower infection rates than revision implants (8% vs 25%; p = 0.001). The rates of infection in silver-coated and non-silver-coated prosthesis were similar (17.4% vs 19.%; p = 0.869). The incidence of hip dislocation was 10%. Rotating hinge prosthesis had a lower failure rate than fixed hinge prosthesis (5.3% vs 11%). After Cox regression, the independent factors associated with failures were the history of previous operations (hazard ratio (HR) 3.7; p = 0.041), and the associated arthroplasty of the proximal tibia (HR 3.8; p = 0.034). At last follow-up, 11 patients (13%) required amputation. Conclusion. TFEPR offers a reliable reconstruction option for massive bone loss of the femur, with a good survival when the prosthesis is used as a primary implant. The use of a rotating hinge at the knee and dual mobility bearing at the hip may be adequate to reduce the risk of mechanical and soft-tissue failures. Infection remains the main concern and there is insufficient evidence to support the routine use of silver-coated endoprosthesis. Cite this article: Bone Joint J 2019;101-B:522–528


The Bone & Joint Journal
Vol. 98-B, Issue 10_Supple_B | Pages 3 - 10
1 Oct 2016
Hamilton TW Pandit HG Lombardi AV Adams JB Oosthuizen CR Clavé A Dodd CAF Berend KR Murray DW

Aims

An evidence-based radiographic Decision Aid for meniscal-bearing unicompartmental knee arthroplasty (UKA) has been developed and this study investigates its performance at an independent centre.

Patients and Methods

Pre-operative radiographs, including stress views, from a consecutive cohort of 550 knees undergoing arthroplasty (UKA or total knee arthroplasty; TKA) by a single-surgeon were assessed. Suitability for UKA was determined using the Decision Aid, with the assessor blinded to treatment received, and compared with actual treatment received, which was determined by an experienced UKA surgeon based on history, examination, radiographic assessment including stress radiographs, and intra-operative assessment in line with the recommended indications as described in the literature.


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 623 - 631
1 May 2017
Blaney J Harty H Doran E O’Brien S Hill J Dobie I Beverland D

Aims

Our aim was to examine the clinical and radiographic outcomes in 257 consecutive Oxford unicompartmental knee arthroplasties (OUKAs) (238 patients), five years post-operatively.

Patients and Methods

A retrospective evaluation was undertaken of patients treated between April 2008 and October 2010 in a regional centre by two non-designing surgeons with no previous experience of UKAs. The Oxford Knee Scores (OKSs) were recorded and fluoroscopically aligned radiographs were assessed post-operatively at one and five years.


Bone & Joint Open
Vol. 5, Issue 5 | Pages 401 - 410
20 May 2024
Bayoumi T Burger JA van der List JP Sierevelt IN Spekenbrink-Spooren A Pearle AD Kerkhoffs GMMJ Zuiderbaan HA

Aims. The primary objective of this registry-based study was to compare patient-reported outcomes of cementless and cemented medial unicompartmental knee arthroplasty (UKA) during the first postoperative year. The secondary objective was to assess one- and three-year implant survival of both fixation techniques. Methods. We analyzed 10,862 cementless and 7,917 cemented UKA cases enrolled in the Dutch Arthroplasty Registry, operated between 2017 and 2021. Pre- to postoperative change in outcomes at six and 12 months’ follow-up were compared using mixed model analyses. Kaplan-Meier and Cox regression models were applied to quantify differences in implant survival. Adjustments were made for patient-specific variables and annual hospital volume. Results. Change from baseline in the Oxford Knee Score (OKS) and activity-related pain was comparable between groups. Adjustment for covariates demonstrated a minimally greater decrease in rest-related pain in the cemented group (β = -0.09 (95% confidence interval (CI) -0.16 to -0.01)). Cementless fixation was associated with a higher probability of achieving an excellent OKS outcome (> 41 points) (adjusted odds ratio 1.2 (95% CI 1.1 to 1.3)). The likelihood of one-year implant survival was greater for cemented implants (adjusted hazard ratio (HR) 1.35 (95% CI 1.01 to 1.71)), with higher revision rates for periprosthetic fractures of cementless implants. During two to three years’ follow-up, the likelihood of implant survival was non-significantly greater for cementless UKA (adjusted HR 0.64 (95% CI 0.40 to 1.04)), primarily due to increased revision rates for tibial loosening of cemented implants. Conclusion. Cementless and cemented medial UKA led to comparable improvement in physical function and pain reduction during the initial postoperative year, albeit with a greater likelihood of achieving excellent OKS outcomes after cementless UKA. Anticipated differences in early physical function and pain should not be a decisive factor in the choice of fixation technique. However, surgeons should consider the differences in short- and long-term implant survival when deciding which implant to use. Cite this article: Bone Jt Open 2024;5(5):401–410


The Bone & Joint Journal
Vol. 105-B, Issue 9 | Pages 1000 - 1006
1 Sep 2023
Macken AA Haagmans-Suman A Spekenbrink-Spooren A van Noort A van den Bekerom MPJ Eygendaal D Buijze GA

Aims. The current evidence comparing the two most common approaches for reverse total shoulder arthroplasty (rTSA), the deltopectoral and anterosuperior approach, is limited. This study aims to compare the rate of loosening, instability, and implant survival between the two approaches for rTSA using data from the Dutch National Arthroplasty Registry with a minimum follow-up of five years. Methods. All patients in the registry who underwent a primary rTSA between January 2014 and December 2016 using an anterosuperior or deltopectoral approach were included, with a minimum follow-up of five years. Cox and logistic regression models were used to assess the association between the approach and the implant survival, instability, and glenoid loosening, independent of confounders. Results. In total, 3,902 rTSAs were included. A deltopectoral approach was used in 54% (2,099/3,902) and an anterosuperior approach in 46% (1,803/3,902). Overall, the mean age in the cohort was 75 years (50 to 96) and the most common indication for rTSA was cuff tear arthropathy (35%; n = 1,375), followed by osteoarthritis (29%; n = 1,126), acute fracture (13%; n = 517), post-traumatic sequelae (10%; n = 398), and an irreparable cuff rupture (5%; n = 199). The two high-volume centres performed the anterosuperior approach more often compared to the medium- and low-volume centres (p < 0.001). Of the 3,902 rTSAs, 187 were revised (5%), resulting in a five-year survival of 95.4% (95% confidence interval 94.7 to 96.0; 3,137 at risk). The most common reason for revision was a periprosthetic joint infection (35%; n = 65), followed by instability (25%; n = 46) and loosening (25%; n = 46). After correcting for relevant confounders, the revision rate for glenoid loosening, instability, and the overall implant survival did not differ significantly between the two approaches (p = 0.494, p = 0.826, and p = 0.101, respectively). Conclusion. The surgical approach used for rTSA did not influence the overall implant survival or the revision rate for instability or glenoid loosening. Cite this article: Bone Joint J 2023;105-B(9):1000–1006