Advertisement for orthosearch.org.uk
Results 1 - 20 of 273
Results per page:
The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 55 - 63
1 Jan 2020
Hagberg K Ghassemi Jahani S Kulbacka-Ortiz K Thomsen P Malchau H Reinholdt C

Aims. The aim of this study was to describe implant and patient-reported outcome in patients with a unilateral transfemoral amputation (TFA) treated with a bone-anchored, transcutaneous prosthesis. Methods. In this cohort study, all patients with a unilateral TFA treated with the Osseointegrated Prostheses for the Rehabilitation of Amputees (OPRA) implant system in Sahlgrenska University Hospital, Gothenburg, Sweden, between January 1999 and December 2017 were included. The cohort comprised 111 patients (78 male (70%)), with a mean age 45 years (17 to 70). The main reason for amputation was trauma in 75 (68%) and tumours in 23 (21%). Patients answered the Questionnaire for Persons with Transfemoral Amputation (Q-TFA) before treatment and at two, five, seven, ten, and 15 years’ follow-up. A prosthetic activity grade was assigned to each patient at each timepoint. All mechanical complications, defined as fracture, bending, or wear to any part of the implant system resulting in removal or change, were recorded. Results. The Q-TFA scores at two, five, seven, and ten years showed significantly more prosthetic use, better mobility, fewer problems, and an improved global situation, compared with baseline. The survival rate of the osseointegrated implant part (the fixture) was 89% and 72% after seven and 15 years, respectively. A total of 61 patients (55%) had mechanical complications (mean 3.3 (SD 5.76)), resulting in exchange of the percutaneous implant parts. There was a positive relationship between a higher activity grade and the number of mechanical complications. Conclusion. Compared with before treatment, the patient-reported outcome was significantly better and remained so over time. Although osseointegration and the ability to transfer loads over a 15-year period have been demonstrated, a large number of mechanical failures in the external implant parts were found. Since these were related to higher activity, restrictions in activity and improvements to the mechanical properties of the implant system are required. Cite this article: Bone Joint J 2020;102-B(1):55–63


Bone & Joint Open
Vol. 3, Issue 10 | Pages 741 - 745
1 Oct 2022
Baldock TE Dixon JR Koubaesh C Johansen A Eardley WGP

Aims. Patients with A1 and A2 trochanteric hip fractures represent a substantial proportion of trauma caseload, and national guidelines recommend that sliding hip screws (SHS) should be used for these injuries. Despite this, intramedullary nails (IMNs) are routinely implanted in many hospitals, at extra cost and with unproven patient outcome benefit. We have used data from the National Hip Fracture Database (NHFD) to examine the use of SHS and IMN for A1 and A2 hip fractures at a national level, and to define the cost implications of management decisions that run counter to national guidelines. Methods. We used the NHFD to identify all operations for fixation of trochanteric fractures in England and Wales between 1 January 2021 and 31 December 2021. A uniform price band from each of three hip fracture implant manufacturers was used to set cost implications alongside variation in implant use. Results. We identified 18,156 A1 and A2 trochanteric hip fractures in 162 centres. Of these, 13,483 (74.3%) underwent SHS fixation, 2,352 (13.0%) were managed with short IMN, and 2,321 (12.8%) were managed with long IMN. Total cost of IMN added up to £1.89 million in 2021, and the clinical justification for this is unclear since rates of IMN use varied from 0% to 97% in different centres. Conclusion. Most trochanteric hip fractures are managed with SHS, in keeping with national guidelines. There is considerable variance between hospitals for implant choice, despite the lack of evidence for clinical benefit and cost-effectiveness of more expensive nailing systems. This suggests either a lack of awareness of national guidelines or a choice not to follow them. We encourage provider units to reassess their practice if outwith the national norm. Funding bodies should examine implant use closely in this population to prevent resource waste at a time of considerable health austerity. Cite this article: Bone Jt Open 2022;3(10):741–745


The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 114 - 121
1 Jan 2014
Pekmezci M McDonald E Buckley J Kandemir U

We investigated a new intramedullary locking nail that allows the distal interlocking screws to be locked to the nail. We compared fixation using this new implant with fixation using either a conventional nail or a locking plate in a laboratory simulation of an osteoporotic fracture of the distal femur. A total of 15 human cadaver femora were used to simulate an AO 33-A3 fracture pattern. Paired specimens compared fixation using either a locking or non-locking retrograde nail, and using either a locking retrograde nail or a locking plate. The constructs underwent cyclical loading to simulate single-leg stance up to 125 000 cycles. Axial and torsional stiffness and displacement, cycles to failure and modes of failure were recorded for each specimen. When compared with locking plate constructs, locking nail constructs had significantly longer mean fatigue life (75 800 cycles (. sd. 33 900) vs 12 800 cycles (. sd. 6100); p = 0.007) and mean axial stiffness (220 N/mm (. sd. 80) vs 70 N/mm (. sd. 18); p = 0.005), but lower mean torsional stiffness (2.5 Nm/° (. sd. 0.9) vs 5.1 Nm/° (. sd. 1.5); p = 0.008). In addition, in the nail group the mode of failure was either cut-out of the distal screws or breakage of nails, and in the locking plate group breakage of the plate was always the mode of failure. Locking nail constructs had significantly longer mean fatigue life than non-locking nail constructs (78 900 cycles (. sd. 25 600) vs 52 400 cycles (. sd. 22 500); p = 0.04). The new locking retrograde femoral nail showed better stiffness and fatigue life than locking plates, and superior fatigue life to non-locking nails, which may be advantageous in elderly patients. Cite this article: Bone Joint J 2014;96-B:114–21


The Bone & Joint Journal
Vol. 99-B, Issue 1 | Pages 128 - 133
1 Jan 2017
Socci AR Casemyr NE Leslie MP Baumgaertner MR

Aims. The aim of this paper is to review the evidence relating to the anatomy of the proximal femur, the geometry of the fracture and the characteristics of implants and methods of fixation of intertrochanteric fractures of the hip. Materials and Methods. Relevant papers were identified from appropriate clinical databases and a narrative review was undertaken. Results. Stable, unstable, and subtrochanteric intertrochanteric fractures vary widely in their anatomical and biomechanical characteristics, as do the implants used for their fixation. The optimal choice of implant addresses the stability of the fracture and affects the outcome. Conclusion. The treatment of intertrochanteric fractures of the hip has evolved along with changes in the design of the implants used to fix them, but there remains conflicting evidence to guide the choice of implant. We advocate fixation of 31A1 fractures with a sliding hip screw and all others with an intramedullary device. Cite this article: Bone Joint J 2017;99-B:128–33


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 157 - 167
1 Jan 2022
Makaram NS Goudie EB Robinson CM

Aims

Open reduction and plate fixation (ORPF) for displaced proximal humerus fractures can achieve reliably good long-term outcomes. However, a minority of patients have persistent pain and stiffness after surgery and may benefit from open arthrolysis, subacromial decompression, and removal of metalwork (ADROM). The long-term results of ADROM remain unknown; we aimed to assess outcomes of patients undergoing this procedure for stiffness following ORPF, and assess predictors of poor outcome.

Methods

Between 1998 and 2018, 424 consecutive patients were treated with primary ORPF for proximal humerus fracture. ADROM was offered to symptomatic patients with a healed fracture at six months postoperatively. Patients were followed up retrospectively with demographic data, fracture characteristics, and complications recorded. Active range of motion (aROM), Oxford Shoulder Score (OSS), and EuroQol five-dimension three-level questionnaire (EQ-5D-3L) were recorded preoperatively and postoperatively.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 3 | Pages 401 - 405
1 Mar 2010
Tan K Lim C Lim AY

The treatment of infected exposed implants which have been used for internal fixation usually involves debridement and removal of the implant. This can result in an unstable fracture or spinal column. Muscle flaps may be used to salvage these implants since they provide soft-tissue cover and fresh vascularity. However, there have been few reports concerning their use and these have concentrated on the eradication of the infection and successful soft-tissue cover as the endpoint. There is no information on the factors which may influence the successful salvage of the implant using muscle flaps. We studied the results and factors affecting outcome in nine pedicled muscle flaps used in the treatment of exposed metal internal fixation with salvage of the implant as the primary endpoint. This was achieved in four cases. Factors predicting success were age < 30 years, the absence of comorbid conditions and a favourable microbiological profile. The growth of multiple organisms, a history of smoking and the presence of methicillin-resistant Staphylococcus aureus on wound cultures indicated a poor outcome. The use of antibiotic beads, vacuum-assisted closure and dressing, the surgical site, the type of flap performed and the time from primary surgery to flap cover were not predictive of outcome


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1557 - 1566
1 Nov 2012
Jameson SS Kyle J Baker PN Mason J Deehan DJ McMurtry IA Reed MR

United Kingdom National Institute for Health and Clinical Excellence guidelines recommend the use of total hip replacement (THR) for displaced intracapsular fractures of the femoral neck in cognitively intact patients, who were independently mobile prior to the injury. This study aimed to analyse the risk factors associated with revision of the implant and mortality following THR, and to quantify risk. National Joint Registry data recording a THR performed for acute fracture of the femoral neck between 2003 and 2010 were analysed. Cox proportional hazards models were used to investigate the extent to which risk of revision was related to specific covariates. Multivariable logistic regression was used to analyse factors affecting peri-operative mortality (< 90 days). A total of 4323 procedures were studied. There were 80 patients who had undergone revision surgery at the time of censoring (five-year revision rate 3.25%, 95% confidence interval 2.44 to 4.07) and 137 patients (3.2%) patients died within 90 days. After adjusting for patient and surgeon characteristics, an increased risk of revision was associated with the use of cementless prostheses compared with cemented (hazard ratio (HR) 1.33, p = 0.021). Revision was independent of bearing surface and head size. The risk of mortality within 90 days was significantly increased with higher American Society of Anesthesiologists (ASA) grade (grade 3: odds ratio (OR) 4.04, p < 0.001; grade 4/5: OR 20.26, p < 0.001; both compared with grades 1/2) and older age (≥ 75 years: OR 1.65, p = 0.025), but reduced over the study period (9% relative risk reduction per year). THR is a good option in patients aged < 75 years and with ASA 1/2. Cementation of the femoral component does not adversely affect peri-operative mortality but improves survival of the implant in the mid-term when compared with cementless femoral components. There are no benefits of using head sizes > 28 mm or bearings other than metal-on-polyethylene. More research is required to determine the benefits of THR over hemiarthroplasty in older patients and those with ASA grades > 2


Bone & Joint Open
Vol. 3, Issue 9 | Pages 710 - 715
5 Sep 2022
Khan SK Tyas B Shenfine A Jameson SS Inman DS Muller SD Reed MR

Aims. Despite multiple trials and case series on hip hemiarthroplasty designs, guidance is still lacking on which implant to use. One particularly deficient area is long-term outcomes. We present over 1,000 consecutive cemented Thompson’s hemiarthroplasties over a ten-year period, recording all accessible patient and implant outcomes. Methods. Patient identifiers for a consecutive cohort treated between 1 January 2003 and 31 December 2011 were linked to radiographs, surgical notes, clinic letters, and mortality data from a national dataset. This allowed charting of their postoperative course, complications, readmissions, returns to theatre, revisions, and deaths. We also identified all postoperative attendances at the Emergency and Outpatient Departments, and recorded any subsequent skeletal injuries. Results. In total, 1,312 Thompson’s hemiarthroplasties were analyzed (mean age at surgery 82.8 years); 125 complications were recorded, necessitating 82 returns to theatre. These included 14 patients undergoing aspiration or manipulation under anaesthesia, 68 reoperations (5.2%) for debridement and implant retention (n = 12), haematoma evacuation (n = 2), open reduction for dislocation (n = 1), fixation of periprosthetic fracture (n = 5), and 48 revised stems (3.7%), for infection (n = 13), dislocation (n = 12), aseptic loosening (n = 9), persistent pain (n = 6), periprosthetic fracture (n = 4), acetabular erosion (n = 3), and metastatic bone disease (n = 1). Their status at ten years is summarized as follows: 1,180 (89.9%) dead without revision, 34 (2.6%) dead having had revision, 84 (6.6%) alive with the stem unrevised, and 14 (1.1%) alive having had revision. Cumulative implant survivorship was 90.3% at ten years; patient survivorship was 7.4%. Conclusion. The Thompson’s stem demonstrates very low rates of complications requiring reoperation and revision, up to ten years after the index procedure. Fewer than one in ten patients live for ten years after fracture. This study supports the use of a cemented Thompson’s implant as a cost-effective option for frail hip fracture patients. Cite this article: Bone Jt Open 2022;3(9):710–715


Bone & Joint Open
Vol. 4, Issue 8 | Pages 602 - 611
21 Aug 2023
James HK Pattison GTR Griffin J Fisher JD Griffin DR

Aims. To evaluate if, for orthopaedic trainees, additional cadaveric simulation training or standard training alone yields superior radiological and clinical outcomes in patients undergoing dynamic hip screw (DHS) fixation or hemiarthroplasty for hip fracture. Methods. This was a preliminary, pragmatic, multicentre, parallel group randomized controlled trial in nine secondary and tertiary NHS hospitals in England. Researchers were blinded to group allocation. Overall, 40 trainees in the West Midlands were eligible: 33 agreed to take part and were randomized, five withdrew after randomization, 13 were allocated cadaveric training, and 15 were allocated standard training. The intervention was an additional two-day cadaveric simulation course. The control group received standard on-the-job training. Primary outcome was implant position on the postoperative radiograph: tip-apex distance (mm) (DHS) and leg length discrepancy (mm) (hemiarthroplasty). Secondary clinical outcomes were procedure time, length of hospital stay, acute postoperative complication rate, and 12-month mortality. Procedure-specific secondary outcomes were intraoperative radiation dose (for DHS) and postoperative blood transfusion requirement (hemiarthroplasty). Results. Eight female (29%) and 20 male trainees (71%), mean age 29.4 years, performed 317 DHS operations and 243 hemiarthroplasties during ten months of follow-up. Primary analysis was a random effect model with surgeon-level fixed effects of patient condition, patient age, and surgeon experience, with a random intercept for surgeon. Under the intention-to-treat principle, for hemiarthroplasty there was better implant position in favour of cadaveric training, measured by leg length discrepancy ≤ 10 mm (odds ratio (OR) 4.08 (95% confidence interval (CI) 1.17 to 14.22); p = 0.027). There were significantly fewer postoperative blood transfusions required in patients undergoing hemiarthroplasty by cadaveric-trained compared to standard-trained surgeons (OR 6.00 (95% CI 1.83 to 19.69); p = 0.003). For DHS, there was no significant between-group difference in implant position as measured by tip-apex distance ≤ 25 mm (OR 6.47 (95% CI 0.97 to 43.05); p = 0.053). No between-group differences were observed for any secondary clinical outcomes. Conclusion. Trainees randomized to additional cadaveric training performed hip fracture fixation with better implant positioning and fewer postoperative blood transfusions in hemiarthroplasty. This effect, which was previously unknown, may be a consequence of the intervention. Further study is required. Cite this article: Bone Jt Open 2023;4(8):602–611


The Bone & Joint Journal
Vol. 104-B, Issue 8 | Pages 987 - 996
1 Aug 2022

Aims. The aim of this study was to describe the demographic details of patients who sustain a femoral periprosthetic fracture (PPF), the epidemiology of PPFs, PPF characteristics, and the predictors of PPF types in the UK population. Methods. This is a multicentre retrospective cohort study including adult patients presenting to hospital with a new PPF between 1 January 2018 and 31 December 2018. Data collected included: patient characteristics, comorbidities, anticoagulant use, social circumstances, level of mobility, fracture characteristics, Unified Classification System (UCS) type, and details of the original implant. Descriptive analysis by fracture location was performed, and predictors of PPF type were assessed using mixed-effects logistic regression models. Results. In total, 720 femoral PPFs from 27 NHS sites were included. PPF patients were typically elderly (mean 79.9 years (SD 10.6)), female (n = 455; 63.2%), had at least one comorbidity (n = 670; 93.1%), and were reliant on walking aids or bed-/chair-bound prior to admission (n = 419; 61.7%). The study population included 539 (74.9%) hip PPFs, 151 (21.0%) knee PPFs, and 30 (4.2%) dividing type PPFs. For hip (n = 407; 75.5%) and knee (n = 88; 58.3%) arthroplasty UCS B type fractures were most common. Overall, 556 (86.2%) were treated in the presenting hospital and 89 (13.8%) required transfer for treatment. Female sex was the only significant predictor of fracture type (A/B1/C type versus B2/B3) for femoral hip PPFs (odds ratio 0.61 (95% confidence interval 0.41 to 0.91); p = 0.014). Sex, residence type, primary versus revision implant PPF, implant fixation, and time between arthroplasty and PPF were not found to predict fracture type for hip PPFs. Conclusion. This multicentre analysis describes patient and injury factors for patients presenting with femoral PPFs to centres across the UK. These patients are generally elderly and frail, comparable to those sustaining a hip fracture. These data can be useful in planning future services and clinical trials. Cite this article: Bone Joint J 2022;104-B(8):987–996


Bone & Joint Open
Vol. 5, Issue 6 | Pages 452 - 456
1 Jun 2024
Kennedy JW Rooney EJ Ryan PJ Siva S Kennedy MJ Wheelwright B Young D Meek RMD

Aims. Femoral periprosthetic fractures are rising in incidence. Their management is complex and carries a high associated mortality. Unlike native hip fractures, there are no guidelines advising on time to theatre in this group. We aim to determine whether delaying surgical intervention influences morbidity or mortality in femoral periprosthetic fractures. Methods. We identified all periprosthetic fractures around a hip or knee arthroplasty from our prospectively collated database between 2012 and 2021. Patients were categorized into early or delayed intervention based on time from admission to surgery (early = ≤ 36 hours, delayed > 36 hours). Patient demographics, existing implants, Unified Classification System fracture subtype, acute medical issues on admission, preoperative haemoglobin, blood transfusion requirement, and length of hospital stay were identified for all patients. Complication and mortality rates were compared between groups. Results. A total of 365 patients were identified: 140 in the early and 225 in the delayed intervention group. Mortality rate was 4.1% at 30 days and 19.2% at one year. There was some indication that those who had surgery within 36 hours had a higher mortality rate, but this did not reach statistical significance at 30 days (p = 0.078) or one year (p = 0.051). Univariate analysis demonstrated that age, preoperative haemoglobin, acute medical issue on admission, and the presence of postoperative complications influenced 30-day and one-year mortality. Using a multivariate model, age and preoperative haemoglobin were independently predictive factors for one-year mortality (odds ratio (OR) 1.071; p < 0.001 and OR 0.980; p = 0.020). There was no association between timing of surgery and postoperative complications. Postoperative complications were more likely with increasing age (OR 1.032; p = 0.001) and revision arthroplasty compared to internal fixation (OR 0.481; p = 0.001). Conclusion. While early intervention may be preferable to reduce prolonged immobilization, there is no evidence that delaying surgery beyond 36 hours increases mortality or complications in patients with a femoral periprosthetic fracture. Cite this article: Bone Jt Open 2024;5(6):452–456


The Bone & Joint Journal
Vol. 106-B, Issue 1 | Pages 77 - 85
1 Jan 2024
Foster AL Warren J Vallmuur K Jaiprakash A Crawford R Tetsworth K Schuetz MA

Aims. The aim of this study was to perform the first population-based description of the epidemiological and health economic burden of fracture-related infection (FRI). Methods. This is a retrospective cohort study of operatively managed orthopaedic trauma patients from 1 January 2007 to 31 December 2016, performed in Queensland, Australia. Record linkage was used to develop a person-centric, population-based dataset incorporating routinely collected administrative, clinical, and health economic information. The FRI group consisted of patients with International Classification of Disease 10th Revision diagnosis codes for deep infection associated with an implanted device within two years following surgery, while all others were deemed not infected. Demographic and clinical variables, as well as healthcare utilization costs, were compared. Results. There were 111,402 patients operatively managed for orthopaedic trauma, with 2,775 of these (2.5%) complicated by FRI. The development of FRI had a statistically significant association with older age, male sex, residing in rural/remote areas, Aboriginal or Torres Strait Islander background, lower socioeconomic status, road traffic accident, work-related injuries, open fractures, anatomical region (lower limb, spine, pelvis), high injury severity, requiring soft-tissue coverage, and medical comorbidities (univariate analysis). Patients with FRI had an eight-times longer median inpatient length of stay (24 days vs 3 days), and a 2.8-times higher mean estimated inpatient hospitalization cost (AU$56,565 vs AU$19,773) compared with uninfected patients. The total estimated inpatient cost of the FRI cohort to the healthcare system was AU$156.9 million over the ten-year period. Conclusion. The results of this study advocate for improvements in trauma care and infection management, address social determinants of health, and highlight the upside potential to improve prevention and treatment strategies. Cite this article: Bone Joint J 2024;106-B(1):77–85


Bone & Joint Open
Vol. 4, Issue 2 | Pages 104 - 109
20 Feb 2023
Aslam AM Kennedy J Seghol H Khisty N Nicols TA Adie S

Aims. Patient decision aids have previously demonstrated an improvement in the quality of the informed consent process. This study assessed the effectiveness of detailed written patient information, compared to standard verbal consent, in improving postoperative recall in adult orthopaedic trauma patients. Methods. This randomized controlled feasibility trial was conducted at two teaching hospitals within the South Eastern Sydney Local Health District. Adult patients (age ≥ 18 years) pending orthopaedic trauma surgery between March 2021 and September 2021 were recruited and randomized to detailed or standard methods of informed consent using a random sequence concealed in sealed, opaque envelopes. The detailed group received procedure-specific written information in addition to the standard verbal consent. The primary outcome was total recall, using a seven-point interview-administered recall questionnaire at 72 hours postoperatively. Points were awarded if the participant correctly recalled details of potential complications (maximum three points), implants used (maximum three points), and postoperative instructions (maximum one point). Secondary outcomes included the anxiety subscale of the Hospital and Anxiety Depression Scale (HADS-A) and visual analogue scale (VAS) for pain collected at 24 hours preoperatively and 72 hours postoperatively. Additionally, the Patient Satisfaction Questionnaire Short Form (PSQ-18) measured satisfaction at 72 hours postoperatively. Results. A total of 60 patients were randomized, 32 to the standard group and 28 to the detailed group. Patients in the detailed group had significantly higher total recall score compared to the standard group (mean difference 1.29 points (95% confidence interval (CI) 0.51 to 2.08); p = 0.002). There were no differences in HADS-A (mean difference 0.39 (95% CI -2.11 to 2.88); p = 0.757), VAS pain (mean difference 5.71 (95% CI -22.25 to 11.11); p = 0.499), or PSQ-18 (mean difference 0.499; 95% CI -1.6 to 3.42; p = 0.392). Conclusion. Detailed written tools are useful in improving postoperative recall in adult orthopaedic trauma patients. Cite this article: Bone Jt Open 2023;4(2):104–109


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 775 - 781
1 Apr 2021
Mellema JJ Janssen S Schouten T Haverkamp D van den Bekerom MPJ Ring D Doornberg JN

Aims. This study evaluated variation in the surgical treatment of stable (A1) and unstable (A2) trochanteric hip fractures among an international group of orthopaedic surgeons, and determined the influence of patient, fracture, and surgeon characteristics on choice of implant (intramedullary nailing (IMN) versus sliding hip screw (SHS)). Methods. A total of 128 orthopaedic surgeons in the Science of Variation Group evaluated radiographs of 30 patients with Type A1 and A2 trochanteric hip fractures and indicated their preferred treatment: IMN or SHS. The management of Type A3 (reverse obliquity) trochanteric fractures was not evaluated. Agreement between surgeons was calculated using multirater kappa. Multivariate logistic regression models were used to assess whether patient, fracture, and surgeon characteristics were independently associated with choice of implant. Results. The overall agreement between surgeons on implant choice was fair (kappa = 0.27 (95% confidence interval (CI) 0.25 to 0.28)). Factors associated with preference for IMN included USA compared to Europe or the UK (Europe odds ratio (OR) 0.56 (95% CI 0.47 to 0.67); UK OR 0.16 (95% CI 0.12 to 0.22); p < 0.001); exposure to IMN only during training compared to surgeons that were exposed to both (only IMN during training OR 2.6 (95% CI 2.0 to 3.4); p < 0.001); and A2 compared to A1 fractures (Type A2 OR 10 (95% CI 8.4 to 12); p < 0.001). Conclusion. In an international cohort of orthopaedic surgeons, there was a large variation in implant preference for patients with A1 and A2 trochanteric fractures. This is due to surgeon bias (country of practice and aspects of training). The observation that surgeons favoured the more expensive implant (IMN) in the absence of convincing evidence of its superiority suggests that surgeon de-biasing strategies may be a useful focus for optimizing patient outcomes and promoting value-based healthcare. Cite this article: Bone Joint J 2021;103-B(4):775–781


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 274 - 282
1 Feb 2022
Grønhaug KML Dybvik E Matre K Östman B Gjertsen J

Aims. The aim of this study was to investigate if there are differences in outcome between sliding hip screws (SHSs) and intramedullary nails (IMNs) with regard to fracture stability. Methods. We assessed data from 17,341 patients with trochanteric or subtrochanteric fractures treated with SHS or IMN in the Norwegian Hip Fracture Register from 2013 to 2019. Primary outcome measures were reoperations for stable fractures (AO Foundation/Orthopaedic Trauma Association (AO/OTA) type A1) and unstable fractures (AO/OTA type A2, A3, and subtrochanteric fractures). Secondary outcome measures were reoperations for A2, A3, and subtrochanteric fractures individually, one-year mortality, quality of life (EuroQol five-dimension three-level index score), pain (visual analogue scale (VAS)), and satisfaction (VAS) for stable and unstable fractures. Hazard rate ratios (HRRs) for reoperation were calculated using Cox regression analysis with adjustments for age, sex, and American Society of Anesthesiologists score. Results. Reoperation rate was lower after surgery with IMN for unstable fractures one year (HRR 0.82, 95% confidence interval (CI) 0.70 to 0.97; p = 0.022) and three years postoperatively (HRR 0.86, 95% CI 0.74 to 0.99; p = 0.036), compared with SHS. For individual fracture types, no clinically significant differences were found. Lower one-year mortality was found for IMN compared with SHS for stable fractures (HRR 0.87; 95% CI 0.78 to 0.96; p = 0.007), and unstable fractures (HRR 0.91, 95% CI 0.84 to 0.98; p = 0.014). Conclusion. This national register-based study indicates a lower reoperation rate for IMN than SHS for unstable trochanteric and subtrochanteric fractures, but not for stable fractures or individual fracture types. The choice of implant may not be decisive to the outcome of treatment for stable trochanteric fractures in terms of reoperation rate. One-year mortality rate for unstable and stable fractures was lower in patients treated with IMN. Cite this article: Bone Joint J 2022;104-B(2):274–282


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 283 - 289
1 Feb 2022
Cerbasi S Bernasconi A Balato G Dimitri F Zingaretti O Orabona G Pascarella R Mariconda M

Aims. The aims of this study were to assess the pre- and postoperative incidence of deep vein thrombosis (DVT) using routine duplex Doppler ultrasound (DUS), to assess the incidence of pulmonary embolism (PE) using CT angiography, and to identify the factors that predict postoperative DVT in patients with a pelvic and/or acetabular fracture. Methods. All patients treated surgically for a pelvic and/or acetabular fracture between October 2016 and January 2020 were enrolled into this prospective single-centre study. The demographic, medical, and surgical details of the patients were recorded. DVT screening of the lower limbs was routinely performed using DUS before and at six to ten days after surgery. CT angiography was used in patients who were suspected of having PE. Age-adjusted univariate and stepwise multiple logistic regression analysis were used to determine the association between explanatory variables and postoperative DVT. Results. A total of 191 patients were included. A DVT was found preoperatively in 12 patients (6.3%), of which six were proximal. A postoperative DVT was found in 42 patients (22%), of which 27 were proximal. Eight patients (4.2%) had a PE, which was secondary to a DVT in three. None of the 12 patients in whom a vena cava filter was implanted prophylactically had a PE. Multivariate logistic regression analysis indicated that the association with the need for spinal surgery (odds ratio (OR) 19.78 (95% confidence interval (CI) 1.12 to 348.08); p = 0.041), intramedullary nailing of a long bone fracture (OR 4.44 (95% CI 1.05 to 18.86); p = 0.043), an operating time > two hours (OR 3.28 (95% CI 1.09 to 9.88); p = 0.035), and additional trauma surgery (OR 3.1 (95% CI 1.03 to 9.45); p = 0.045) were statistically the most relevant independent predictors of a postoperative DVT. Conclusion. The acknowledgement of the risk factors for the development of a DVT and their weight is crucial to set a threshold for the index of suspicion for this diagnosis by medical staff. We suggest the routine use of the DUS screening for DVT in patients with a pelvic and/or acetabular fracture before and six to ten days after surgery. Cite this article: Bone Joint J 2022;104-B(2):283–289


Bone & Joint Open
Vol. 4, Issue 9 | Pages 659 - 667
1 Sep 2023
Nasser AAHH Osman K Chauhan GS Prakash R Handford C Nandra RS Mahmood A

Aims

Periprosthetic fractures (PPFs) following hip arthroplasty are complex injuries. This study evaluates patient demographic characteristics, management, outcomes, and risk factors associated with PPF subtypes over a decade.

Methods

Using a multicentre collaborative study design, independent of registry data, we identified adults from 29 centres with PPFs around the hip between January 2010 and December 2019. Radiographs were assessed for the Unified Classification System (UCS) grade. Patient and injury characteristics, management, and outcomes were compared between UCS grades. A multinomial logistic regression was performed to estimate relative risk ratios (RRR) of variables on UCS grade.


Bone & Joint Open
Vol. 5, Issue 1 | Pages 46 - 52
19 Jan 2024
Assink N ten Duis K de Vries JPM Witjes MJH Kraeima J Doornberg JN IJpma FFA

Aims

Proper preoperative planning benefits fracture reduction, fixation, and stability in tibial plateau fracture surgery. We developed and clinically implemented a novel workflow for 3D surgical planning including patient-specific drilling guides in tibial plateau fracture surgery.

Methods

A prospective feasibility study was performed in which consecutive tibial plateau fracture patients were treated with 3D surgical planning, including patient-specific drilling guides applied to standard off-the-shelf plates. A postoperative CT scan was obtained to assess whether the screw directions, screw lengths, and plate position were performed according the preoperative planning. Quality of the fracture reduction was assessed by measuring residual intra-articular incongruence (maximum gap and step-off) and compared to a historical matched control group.


Bone & Joint Open
Vol. 4, Issue 5 | Pages 378 - 384
23 May 2023
Jones CS Eardley WGP Johansen A Inman DS Evans JT

Aims

The aim of this study was to describe services available to patients with periprosthetic femoral fracture (PPFF) in England and Wales, with focus on variation between centres and areas for care improvement.

Methods

This work used data freely available from the National Hip Fracture Database (NHFD) facilities survey in 2021, which asked 21 questions about the care of patients with PPFFs, and nine relating to clinical decision-making around a hypothetical case.


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 162 - 169
1 Feb 2020
Hoellwarth JS Tetsworth K Kendrew J Kang NV van Waes O Al-Maawi Q Roberts C Al Muderis M

Aims. Osseointegrated prosthetic limbs allow better mobility than socket-mounted prosthetics for lower limb amputees. Fractures, however, can occur in the residual limb, but they have rarely been reported. Approximately 2% to 3% of amputees with socket-mounted prostheses may fracture within five years. This is the first study which directly addresses the risks and management of periprosthetic osseointegration fractures in amputees. Methods. A retrospective review identified 518 osseointegration procedures which were undertaken in 458 patients between 2010 and 2018 for whom complete medical records were available. Potential risk factors including time since amputation, age at osseointegration, bone density, weight, uni/bilateral implantation and sex were evaluated with multiple logistic regression. The mechanism of injury, technique and implant that was used for fixation of the fracture, pre-osseointegration and post fracture mobility (assessed using the K-level) and the time that the prosthesis was worn for in hours/day were also assessed. Results. There were 22 periprosthetic fractures; they occurred exclusively in the femur: two in the femoral neck, 14 intertrochanteric and six subtrochanteric, representing 4.2% of 518 osseointegration operations and 6.3% of 347 femoral implants. The vast majority (19/22, 86.4%) occurred within 2 cm of the proximal tip of the implant and after a fall. No fractures occurred spontaneously. Fixation most commonly involved dynamic hip screws (10) and reconstruction plates (9). No osseointegration implants required removal, the K-level was not reduced after fixation of the fracture in any patient, and all retained a K-level of ≥ 2. All fractures united, 21 out of 22 patients (95.5%) wear their osseointegration-mounted prosthetic limb longer daily than when using a socket, with 18 out of 22 (81.8%) reporting using it for ≥ 16 hours daily. Regression analysis identified a 3.89-fold increased risk of fracture for females (p = 0.007) and a 1.02-fold increased risk of fracture per kg above a mean of 80.4 kg (p = 0.046). No increased risk was identified for bilateral implants (p = 0.083), time from amputation to osseointegration (p = 0.974), age at osseointegration (p = 0.331), or bone density (g/cm2, p = 0.560; T-score, p = 0.247; Z-score, p = 0.312). Conclusion. The risks and sequelae of periprosthetic fracture after press-fit osseointegration for amputation should not deter patients or clinicians from considering this procedure. Females and heavier patients are likely to have an increased risk of fracture. Age, years since amputation, and bone density do not appear influential. Cite this article: Bone Joint J 2020;102-B(2):162–169