We compared thromboembolic events, major haemorrhage
and death after total hip replacement in patients receiving either
aspirin or low-molecular-weight heparin (LMWH). We analysed data from
the National Joint Registry for England and Wales linked to an administrative
database of hospital admissions in the English National Health Service.
A total of 108 584 patients operated on between April 2003 and September 2008
were included and followed up for 90 days. Multivariable risk modelling
and propensity score matching were used to estimate odds ratios
(OR) adjusted for baseline risk factors. An OR <
1 indicates
that rates are lower with LMWH than with aspirin. In all, 21.1%
of patients were prescribed aspirin and 78.9% LMWH. Without adjustment, we
found no statistically significant differences. The rate of pulmonary
embolism was 0.68% in both groups and 90-day mortality was 0.65%
with aspirin and 0.61% with LMWH (OR 0.93; 95% CI 0.77 to 1.11).
With risk adjustment, the difference in mortality increased (OR
0.84; 95% CI 0.69 to 1.01). With propensity score matching the mortality difference
increased even further to 0.65% with aspirin and 0.51% with LMWH
(OR 0.77; 95% CI 0.61 to 0.98). These results should be considered
when the conflicting recommendations of existing guidelines for
thromboprophylaxis after
Aims. The aim of this study was to perform a systematic review of the evidence for the use of intraoperative cell salvage in patients undergoing revision
Aims. With increasing burden of revision
We obtained pre-operative and six-month post-operative
Oxford hip (OHS) and knee scores (OKS) for 1523 patients who underwent
total
Aims. There is an increasing demand for
Aims. Acetabular edge-loading was a cause of increased wear rates in metal-on-metal hip arthroplasties, ultimately contributing to their failure. Although such wear patterns have been regularly reported in retrieval analyses, this study aimed to determine their in vivo location and investigate their relationship with acetabular component positioning. Methods. 3D CT imaging was combined with a recently validated method of mapping bearing surface wear in retrieved hip implants. The asymmetrical stabilizing fins of Birmingham
Aims. One-stage revision
Aims. Total hip arthroplasty (THA) is one of the most successful surgical procedures. The objectives of this study were to define whether there is a correlation between socioeconomic status (SES) and surgical complications after elective primary unilateral THA, and investigate whether access to elective THA differs within SES groups. Methods. We conducted a retrospective, population-based cohort study involving 202 hospitals in Ontario, Canada, over a 17-year period. Patients were divided into income quintiles based on postal codes as a proxy for personal economic status. Multivariable logistic regression models were then used to primarily assess the relationship between SES and surgical complications within one year of index THA. Results. Of 111,359 patients who underwent elective primary THA, those in the lower SES groups had statistically significantly more comorbidities and statistically significantly more postoperative complications. While there was no increase in readmission rates within 90 days, there was a statistically significant difference in the primary and secondary outcomes including all revisions due (with a subset of deep wound infection and dislocation). Results showed that those in the higher SES groups had proportionally more cases performed than those in lower groups. Compared to the highest SES quintile, the lower groups had 61% of the number of
Aims. This study evaluates the association between consultant and hospital volume and the risk of re-revision and 90-day mortality following first-time revision of primary hip arthroplasty for aseptic loosening. Methods. We conducted a cohort study of first-time, single-stage revision
Objectives. We used the National Joint Registry for England, Wales, Northern Ireland and the Isle of Man (NJR) to investigate the risk of revision due to prosthetic joint infection (PJI) for patients undergoing primary and revision
We investigated the capacity of patient warming
devices to disrupt the ultra-clean airflow system. We compared the effects
of two patient warming technologies, forced-air and conductive fabric,
on operating theatre ventilation during simulated hip replacement
and lumbar spinal procedures using a mannequin as a patient. Infection
data were reviewed to determine whether joint infection rates were
associated with the type of patient warming device that was used. Neutral-buoyancy detergent bubbles were released adjacent to
the mannequin’s head and at floor level to assess the movement of
non-sterile air into the clean airflow over the surgical site. During
simulated
Aims. The aim of this study was to determine satisfaction rates after hip and knee arthroplasty in patients who did not respond to postoperative patient-reported outcome measures (PROMs), characteristics of non-responders, and contact preferences to maximize response rates. Methods. A prospective cohort study of patients planned to undergo
Aims. This study describes the variation in the annual volumes of revision
Aims. Femoral cement-in-cement revision is a well described technique to reduce morbidity and complications in hip revision surgery. Traditional techniques for septic revision of
Aims. The purpose of this study was to evaluate unexpected positive cultures in total hip arthroplasty (THA) revisions for presumed aseptic loosening, to assess the prevalence of low-grade infection using two definition criteria, and to analyze its impact on implant survival after revision. Methods. A total of 274 THA revisions performed for presumed aseptic loosening from 2012 to 2016 were reviewed. In addition to obtaining intraoperative tissue cultures from all patients, synovial and sonication fluid samples of the removed implant were obtained in 215 cases (79%) and 101 cases (37%), respectively. Histopathological analysis was performed in 250 cases (91%). Patients were classified as having low-grade infections according to institutional criteria and Musculoskeletal Infection Society (MSIS) International Consensus Meeting (ICM) 2013 criteria. Low-grade infections according to institutional criteria were treated with targeted antibiotics for six weeks postoperatively. Implant failure was defined as the need for re-revision resulting from periprosthetic joint infection (PJI) and aseptic reasons. The mean follow-up was 68 months (26 to 95). Results. Unexpected positive intraoperative samples were found in 77 revisions (28%). Low-grade infection was diagnosed in 36 cases (13%) using institutional criteria and in nine cases (3%) using MSIS ICM 2013 criteria. In all, 41 patients (15%) had single specimen growth of a low-virulent pathogen and were deemed contaminated. Coagulase-negative Staphylococcus and anaerobes were the most commonly isolated bacteria. Implant failure for PJI was higher in revisions with presumed contaminants (5/41, 12%) compared to those with low-grade infections (2/36, 6%) and those with negative samples (5/197, 3%) (p = 0.021). The rate of all-cause re-revision was similar in patients diagnosed with low-grade infections (5/36, 14%) and those with presumed contaminants (6/41, 15%) and negative samples (21/197, 11%) (p = 0.699). Conclusion. Our findings suggest that the presumption of culture contamination in aseptic revision
Aims. We investigated the long-term performance of the Tripolar Trident acetabular component used for recurrent dislocation in revision total hip arthroplasty. We assessed: 1) rate of re-dislocation; 2) incidence of complications requiring re-operation; and 3) Western Ontario and McMaster Universities osteoarthritis index (WOMAC) pain and functional scores. Patients and Methods. We retrospectively identified 111 patients who had 113 revision tripolar constrained liners between 1994 and 2008. All patients had undergone revision
Ceramic bearings have several desirable properties, such as resistance to wear, hardness, and biocompatibility, that favour it as an articulating surface in
Aims. In countries with social healthcare systems, such as Canada, patients may experience long wait times and a decline in their health status prior to their operation. The aim of this study is to explore the association between long preoperative wait times (WT) and acute hospital length of stay (LoS) for primary arthroplasty of the knee and hip. Methods. The study population was obtained from the provincial Patient Access Registry Nova Scotia (PARNS) and the Canadian national hospital Discharge Access Database (DAD). We included primary total knee and
Our primary aim was to assess reoperation-free survival at one year after the index injury in patients aged ≥ 75 years treated with internal fixation (IF) or arthroplasty for undisplaced femoral neck fractures (uFNFs). Secondary outcomes were reoperations and mortality analyzed separately. We retrieved data on all patients aged ≥ 75 years with an uFNF registered in the Swedish Fracture Register from 2011 to 2018. The database was linked to the Swedish Arthroplasty Register and the National Patient Register to obtain information on comorbidity, mortality, and reoperations. Our primary outcome, reoperation, or death at one year was analyzed using restricted mean survival time, which gives the mean time to either event for each group separately.Aims
Methods
The aims of this study were to determine the success of a reconstruction algorithm used in major acetabular bone loss, and to further define the indications for custom-made implants in major acetabular bone loss. We reviewed a consecutive series of Paprosky type III acetabular defects treated according to a reconstruction algorithm. IIIA defects were planned to use a superior augment and hemispherical acetabular component. IIIB defects were planned to receive either a hemispherical acetabular component plus augments, a cup-cage reconstruction, or a custom-made implant. We used national digital health records and registry reports to identify any reoperation or re-revision procedure and Oxford Hip Score (OHS) for patient-reported outcomes. Implant survival was determined via Kaplan-Meier analysis.Aims
Methods