A total of 56 male patients with a displaced
intracapsular fracture of the hip and a mean age of 81 years (62
to 94), were randomised to be treated with either a cemented hemiarthroplasty
(the Exeter Trauma Stem) or reduction and internal fixation using
the Targon Femoral Plate. All surviving patients were reviewed one
year after the injury, at which time restoration of function and
pain in the hip was assessed. There was no statistically significant
difference in mortality between the two groups (7/26; 26.9% for
hemiarthroplasty These results indicate that cemented hemiarthroplasty gives better
results than internal fixation in elderly men with a displaced intracapsular
fracture of the hip. Cite this article: