The Bone & Joint Journal
Vol. 103-B, Issue 9 | Pages 1449 - 1456
1 Sep 2021
Kazarian GS Lieberman EG Hansen EJ Nunley RM Barrack RL

Aims. The goal of the current systematic review was to assess the impact of implant placement accuracy on outcomes following total knee arthroplasty (TKA). Methods. A systematic review was performed in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines using the Ovid Medline, Embase, Cochrane Central, and Web of Science databases in order to assess the impact of the patient-reported outcomes measures (PROMs) and implant placement accuracy on outcomes following TKA. Studies assessing the impact of implant alignment, rotation, size, overhang, or condylar offset were included. Study quality was assessed, evidence was graded (one-star: no evidence, two-star: limited evidence, three-star: moderate evidence, four-star: strong evidence), and recommendations were made based on the available evidence. Results. A total of 49 studies were identified for inclusion. With respect to PROMs, there was two-star evidence in support of mechanical axis alignment (MAA), femorotibial angle (FTA), femoral coronal angle (FCA), tibial coronal angle (TCA), femoral sagittal angle (FSA), femoral rotation, tibial and combined rotation/mismatch, and implant size/overhang or offset on PROMs, and one-star evidence in support of tibial sagittal angle (TSA), impacting PROMs. With respect to survival, there was three- to four-star evidence in support FTA, FCA, TCA, and TSA, moderate evidence in support of femoral rotation, tibial and combined rotation/mismatch, and limited evidence in support of MAA, FSA, and implant size/overhang or offset impacting survival. Conclusion. Overall, there is limited evidence to suggest that PROMs are impacted by the accuracy of implant placement, and malalignment does not appear to be a significant driver of the observed high rates of patient dissatisfaction following TKA. However, FTA, FCA, TCA, TSA, and implant rotation demonstrate a moderate-strong relationship with implant survival. Efforts should be made to improve the accuracy of these parameters in order to improve TKA survival. Cite this article: Bone Joint J 2021;103-B(9):1449–1456


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 502 - 511
1 May 2019
Lidder S Epstein DJ Scott G

Aims. Short-stemmed femoral implants have been used for total hip arthroplasty (THA) in young and active patients to conserve bone, provide physiological loading, and reduce the incidence of thigh pain. Only short- to mid-term results have been presented and there have been concerns regarding component malalignment, incorrect sizing, and subsidence. This systematic review reports clinical and radiological outcomes, complications, revision rates, and implant survival in THA using short-stemmed femoral components. Materials and Methods. A literature review was performed using the EMBASE, Medline, and Cochrane databases. Strict inclusion and exclusion criteria were used to identify studies reporting clinical and radiological follow-up for short-stemmed hip arthroplasties. Results. A total of 28 studies were eligible for inclusion. This included 5322 hips in 4657 patients with a mean age of 59 years (13 to 94). The mean follow-up was 6.1 years (0.5 to 20). The mean Harris Hip Score improved from 46 (0 to 100) to 92 (39 to 100). The mean Oxford Hip Score improved from 25 (2 to 42.5) to 35 (12.4 to 48). The mean Western Ontario & McMaster Universities Osteoarthritis Index improved from 54 (2 to 95) to 22 (0 to 98). Components were aligned in a neutral coronal alignment in up to 90.9% of cases. A total of 15 studies reported component survivorship, which was 98.6% (92% to 100%) at a mean follow-up of 12.1 years. Conclusion. Short-stemmed femoral implants show similar improvement in clinical and radiological outcomes compared with conventional length implants. Only mid-term survivorship, however, is known. An abundance of short components have been developed and used commercially without staged clinical trials. Long-term survival is still unknown for many of these components. There remains tension between innovation and the moral duty to ensure that the introduction of new implants is controlled until safety and patient benefit are demonstrated. Implant innovation and subsequent use should be driven by proven clinical outcomes, rather than market and financial forces, and ethical practice must be ensured. Cite this article: Bone Joint J 2019;101-B:502–511


Bone & Joint Open
Vol. 5, Issue 5 | Pages 374 - 384
1 May 2024
Bensa A Sangiorgio A Deabate L Illuminati A Pompa B Filardo G

Aims

Robotic-assisted unicompartmental knee arthroplasty (R-UKA) has been proposed as an approach to improve the results of the conventional manual UKA (C-UKA). The aim of this meta-analysis was to analyze the studies comparing R-UKA and C-UKA in terms of clinical outcomes, radiological results, operating time, complications, and revisions.

Methods

The literature search was conducted on three databases (PubMed, Cochrane, and Web of Science) on 20 February 2024 according to the guidelines for Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA). Inclusion criteria were comparative studies, written in the English language, with no time limitations, on the comparison of R-UKA and C-UKA. The quality of each article was assessed using the Downs and Black Checklist for Measuring Quality.


Aims

The aim of this study was to review the current evidence surrounding curve type and morphology on curve progression risk in adolescent idiopathic scoliosis (AIS).

Methods

A comprehensive search was conducted by two independent reviewers on PubMed, Embase, Medline, and Web of Science to obtain all published information on morphological predictors of AIS progression. Search items included ‘adolescent idiopathic scoliosis’, ‘progression’, and ‘imaging’. The inclusion and exclusion criteria were carefully defined. Risk of bias of studies was assessed with the Quality in Prognostic Studies tool, and level of evidence for each predictor was rated with the Grading of Recommendations, Assessment, Development and Evaluations (GRADE) approach. In all, 6,286 publications were identified with 3,598 being subjected to secondary scrutiny. Ultimately, 26 publications (25 datasets) were included in this review.


The Bone & Joint Journal
Vol. 104-B, Issue 5 | Pages 541 - 548
1 May 2022
Zhang J Ng N Scott CEH Blyth MJG Haddad FS Macpherson GJ Patton JT Clement ND

Aims

This systematic review aims to compare the precision of component positioning, patient-reported outcome measures (PROMs), complications, survivorship, cost-effectiveness, and learning curves of MAKO robotic arm-assisted unicompartmental knee arthroplasty (RAUKA) with manual medial unicompartmental knee arthroplasty (mUKA).

Methods

Searches of PubMed, MEDLINE, and Google Scholar were performed in November 2021 according to the Preferred Reporting Items for Systematic Review and Meta-­Analysis statement. Search terms included “robotic”, “unicompartmental”, “knee”, and “arthroplasty”. Published clinical research articles reporting the learning curves and cost-effectiveness of MAKO RAUKA, and those comparing the component precision, functional outcomes, survivorship, or complications with mUKA, were included for analysis.


Bone & Joint Open
Vol. 3, Issue 2 | Pages 114 - 122
1 Feb 2022
Green GL Arnander M Pearse E Tennent D

Aims

Recurrent dislocation is both a cause and consequence of glenoid bone loss, and the extent of the bony defect is an indicator guiding operative intervention. Literature suggests that loss greater than 25% requires glenoid reconstruction. Measuring bone loss is controversial; studies use different methods to determine this, with no clear evidence of reproducibility. A systematic review was performed to identify existing CT-based methods of quantifying glenoid bone loss and establish their reliability and reproducibility

Methods

A Preferred Reporting Items for Systematic reviews and Meta-Analyses-compliant systematic review of conventional and grey literature was performed.


The Bone & Joint Journal
Vol. 102-B, Issue 5 | Pages 556 - 567
1 May 2020
Park JW Lee Y Lee YJ Shin S Kang Y Koo K

Deep gluteal syndrome is an increasingly recognized disease entity, caused by compression of the sciatic or pudendal nerve due to non-discogenic pelvic lesions. It includes the piriformis syndrome, the gemelli-obturator internus syndrome, the ischiofemoral impingement syndrome, and the proximal hamstring syndrome. The concept of the deep gluteal syndrome extends our understanding of posterior hip pain due to nerve entrapment beyond the traditional model of the piriformis syndrome. Nevertheless, there has been terminological confusion and the deep gluteal syndrome has often been undiagnosed or mistaken for other conditions. Careful history-taking, a physical examination including provocation tests, an electrodiagnostic study, and imaging are necessary for an accurate diagnosis.

After excluding spinal lesions, MRI scans of the pelvis are helpful in diagnosing deep gluteal syndrome and identifying pathological conditions entrapping the nerves. It can be conservatively treated with multidisciplinary treatment including rest, the avoidance of provoking activities, medication, injections, and physiotherapy.

Endoscopic or open surgical decompression is recommended in patients with persistent or recurrent symptoms after conservative treatment or in those who may have masses compressing the sciatic nerve.

Many physicians remain unfamiliar with this syndrome and there is a lack of relevant literature. This comprehensive review aims to provide the latest information about the epidemiology, aetiology, pathology, clinical features, diagnosis, and treatment.

Cite this article: Bone Joint J 2020;102-B(5):556–567.