Advertisement for orthosearch.org.uk
Results 1 - 20 of 373
Results per page:
Bone & Joint Open
Vol. 5, Issue 6 | Pages 524 - 531
24 Jun 2024
Woldeyesus TA Gjertsen J Dalen I Meling T Behzadi M Harboe K Djuv A

Aims. To investigate if preoperative CT improves detection of unstable trochanteric hip fractures. Methods. A single-centre prospective study was conducted. Patients aged 65 years or older with trochanteric hip fractures admitted to Stavanger University Hospital (Stavanger, Norway) were consecutively included from September 2020 to January 2022. Radiographs and CT images of the fractures were obtained, and surgeons made individual assessments of the fractures based on these. The assessment was conducted according to a systematic protocol including three classification systems (AO/Orthopaedic Trauma Association (OTA), Evans Jensen (EVJ), and Nakano) and questions addressing specific fracture patterns. An expert group provided a gold-standard assessment based on the CT images. Sensitivities and specificities of surgeons’ assessments were estimated and compared in regression models with correlations for the same patients. Intra- and inter-rater reliability were presented as Cohen’s kappa and Gwet’s agreement coefficient (AC1). Results. We included 120 fractures in 119 patients. Compared to radiographs, CT increased the sensitivity of detecting unstable trochanteric fractures from 63% to 70% (p = 0.028) and from 70% to 76% (p = 0.004) using AO/OTA and EVJ, respectively. Compared to radiographs alone, CT increased the sensitivity of detecting a large posterolateral trochanter major fragment or a comminuted trochanter major fragment from 63% to 76% (p = 0.002) and from 38% to 55% (p < 0.001), respectively. CT improved intra-rater reliability for stability assessment using EVJ (AC1 0.68 to 0.78; p = 0.049) and for detecting a large posterolateral trochanter major fragment (AC1 0.42 to 0.57; p = 0.031). Conclusion. A preoperative CT of trochanteric fractures increased detection of unstable fractures using the AO/OTA and EVJ classification systems. Compared to radiographs, CT improved intra-rater reliability when assessing fracture stability and detecting large posterolateral trochanter major fragments. Cite this article: Bone Jt Open 2024;5(6):524–531


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 961 - 968
1 Jul 2012
Duckworth AD Buijze GA Moran M Gray A Court-Brown CM Ring D McQueen MM

A prospective study was performed to develop a clinical prediction rule that incorporated demographic and clinical factors predictive of a fracture of the scaphoid. Of 260 consecutive patients with a clinically suspected or radiologically confirmed scaphoid fracture, 223 returned for evaluation two weeks after injury and formed the basis of our analysis. Patients were evaluated within 72 hours of injury and at approximately two and six weeks after injury using clinical assessment and standard radiographs. Demographic data and the results of seven specific tests in the clinical examination were recorded. There were 116 (52%) men and their mean age was 33 years (13 to 95; . sd. 17.9). In 62 patients (28%) a scaphoid fracture was confirmed. A logistic regression model identified male gender (p = 0.002), sports injury (p = 0.004), anatomical snuff box pain on ulnar deviation of the wrist within 72 hours of injury (p < 0.001), and scaphoid tubercle tenderness at two weeks (p < 0.001) as independent predictors of fracture. All patients with no pain at the anatomical snuff box on ulnar deviation of the wrist within 72 hours of injury did not have a fracture (n = 72, 32%). With four independently significant factors positive, the risk of fracture was 91%. Our study has demonstrated that clinical prediction rules have a considerable influence on the probability of a suspected scaphoid fracture. This will help improve the use of supplementary investigations where the diagnosis remains in doubt


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 178 - 183
1 Jan 2021
Kubik JF Rollick NC Bear J Diamond O Nguyen JT Kleeblad LJ Wellman DS Helfet DL

Aims. Malreduction of the syndesmosis has been reported in up to 52% of patients after fixation of ankle fractures. Multiple radiological parameters are used to define malreduction; there has been limited investigation of the accuracy of these measurements in differentiating malreduction from inherent anatomical asymmetry. The purpose of this study was to identify the prevalence of positive malreduction standards within the syndesmosis of native, uninjured ankles. Methods. Three observers reviewed 213 bilateral lower limb CT scans of uninjured ankles. Multiple measurements were recorded on the axial CT 1 cm above the plafond: anterior syndesmotic distance; posterior syndesmotic distance; central syndesmotic distance; fibular rotation; and sagittal fibular translation. Previously studied malreduction standards were evaluated on bilateral CT, including differences in: anterior, central and posterior syndesmotic distance; mean syndesmotic distance; fibular rotation; sagittal translational distance; and syndesmotic area. Unilateral CT was used to compare the anterior to posterior syndesmotic distances. Results. A difference of anterior to posterior syndesmotic distance > 2 mm was observed in 89% of ankles (n = 190) on unilateral CT assessment. Using bilateral CT, we found that 35% (n = 75) of normal ankles would be considered malreduced by current malreduction parameters. In 50 patients (23%), only one parameter was anomalous, 18 patients (8%) had two positive parameters and seven patients (3%) had three. Difference in fibular rotation had the lowest false positive rate of all parameters at 6%, whereas posterior syndesmotic distance difference had the highest at 15%. Conclusion. In this study, 35% of native, uninjured syndesmoses (n = 75) would be classified as malreduced by current diagnostic standards on bilateral CT and 89% had an asymmetric incisura on unilateral CT (n = 190). Current radiological parameters are insufficient to differentiate mild inherent anatomical asymmetry from malreduction of the syndesmosis. Cite this article: Bone Joint J 2021;103-B(1):178–183


The Bone & Joint Journal
Vol. 100-B, Issue 6 | Pages 693 - 702
1 Jun 2018
Jayakumar P Overbeek CL Vranceanu A Williams M Lamb S Ring D Gwilym S

Aims. Outcome measures quantifying aspects of health in a precise, efficient, and user-friendly manner are in demand. Computer adaptive tests (CATs) may overcome the limitations of established fixed scales and be more adept at measuring outcomes in trauma. The primary objective of this review was to gain a comprehensive understanding of the psychometric properties of CATs compared with fixed-length scales in the assessment of outcome in patients who have suffered trauma of the upper limb. Study designs, outcome measures and methodological quality are defined, along with trends in investigation. Materials and Methods. A search of multiple electronic databases was undertaken on 1 January 2017 with terms related to “CATs”, “orthopaedics”, “trauma”, and “anatomical regions”. Studies involving adults suffering trauma to the upper limb, and undergoing any intervention, were eligible. Those involving the measurement of outcome with any CATs were included. Identification, screening, and eligibility were undertaken, followed by the extraction of data and quality assessment using the Consensus-Based Standards for the Selection of Health Measurement Instruments (COSMIN) criteria. The review is reported according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) criteria and reg. istered (PROSPERO: CRD42016053886). Results. A total of 31 studies reported trauma conditions alone, or in combination with non-traumatic conditions using CATs. Most were cross-sectional with varying level of evidence, number of patients, type of study, range of conditions and methodological quality. CATs correlated well with fixed scales and had minimal or no floor-ceiling effects. They required significantly fewer questions and/or less time for completion. Patient-Reported Outcomes Measurement Information System (PROMIS) CATs were the most frequently used, and the use of CATs is increasing. Conclusion. Early studies show valid and reliable outcome measurement with CATs performing as well as, if not better than, established fixed scales. Superior properties such as floor-ceiling effects and ease of use support their use in the assessment of outcome after trauma. As CATs are being increasingly used in patient outcomes research, further psychometric evaluation, especially involving longitudinal studies and groups of patients with specific injuries are required to inform clinical practice using these contemporary measures. Cite this article: Bone Joint J 2018;100-B:693–702


The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 151 - 159
1 Feb 2013
Duckworth AD McQueen MM Ring D

Most fractures of the radial head are stable undisplaced or minimally displaced partial fractures without an associated fracture of the elbow or forearm or ligament injury, where stiffness following non-operative management is the primary concern. Displaced unstable fractures of the radial head are usually associated with other fractures or ligament injuries, and restoration of radiocapitellar contact by reconstruction or prosthetic replacement of the fractured head is necessary to prevent subluxation or dislocation of the elbow and forearm. In fractures with three or fewer fragments (two articular fragments and the neck) and little or no metaphyseal comminution, open reduction and internal fixation may give good results. However, fragmented unstable fractures of the radial head are prone to early failure of fixation and nonunion when fixed. Excision of the radial head is associated with good long-term results, but in patients with instability of the elbow or forearm, prosthetic replacement is preferred.

This review considers the characteristics of stable and unstable fractures of the radial head, as well as discussing the debatable aspects of management, in light of the current best evidence.

Cite this article: Bone Joint J 2013;95-B:151–9.


Bone & Joint Research
Vol. 5, Issue 5 | Pages 191 - 197
1 May 2016
Kienast B Kowald B Seide K Aljudaibi M Faschingbauer M Juergens C Gille J

Objectives. The monitoring of fracture healing is a complex process. Typically, successive radiographs are performed and an emerging calcification of the fracture area is evaluated. The aim of this study was to investigate whether different bone healing patterns can be distinguished using a telemetric instrumented femoral internal plate fixator. Materials and Methods. An electronic telemetric system was developed to assess bone healing mechanically. The system consists of a telemetry module which is applied to an internal locking plate fixator, an external reader device, a sensor for measuring externally applied load and a laptop computer with processing software. By correlation between externally applied load and load measured in the implant, the elasticity of the osteosynthesis is calculated. The elasticity decreases with ongoing consolidation of a fracture or nonunion and is an appropriate parameter for the course of bone healing. At our centre, clinical application has been performed in 56 patients suffering nonunion or fracture of the femur. Results. A total of 39 cases of clinical application were reviewed for this study. In total, four different types of healing curves were observed: fast healing; slow healing; plateau followed by healing; and non-healing. Conclusion. The electronically instrumented internal fixator proved to be valuable for the assessment of bone healing in difficult healing situations. Cost-effective manufacturing is possible because the used electronic components are derived from large-scale production. The incorporation of microelectronics into orthopaedic implants will be an important innovation in future clinical care. Cite this article: B. Kienast, B. Kowald, K. Seide, M. Aljudaibi, M. Faschingbauer, C. Juergens, J. Gille. An electronically instrumented internal fixator for the assessment of bone healing. Bone Joint Res 2016;5:191–197. DOI: 10.1302/2046-3758.55.2000611


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 690 - 695
1 May 2016
Dodd A Osterhoff G Guy P Lefaivre KA

We performed a systematic review of the literature pertaining to the functional outcomes of the surgical management of acetabular fractures. A total of 69 articles met our inclusion criteria, revealing that eight generic outcome instruments were used, along with five specific instruments. The majority of studies reported outcomes using a version of the d’Aubigne and Postel score, which has not been validated for use in acetabular fracture. Few validated outcome measures were reported. No psychometric testing of outcome instruments was performed. The current assessment of outcomes in surgery for acetabular fractures lacks scientific rigour, and does not give reliable outcome data for either scientific comparison or patient counselling. Take home message: The use of non-validated functional outcome measures is a major limitation of the current literature pertaining to surgical management of acetabular fractures; future studies should use validated outcome measures to ensure the legitimacy of the reported results. Cite this article: Bone Joint J 2016;98-B:690–5


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 5 | Pages 705 - 713
1 Jul 2004
Bhat M McCarthy M Davis TRC Oni JA Dawson S

We treated 50 patients with fractures of the waist of the scaphoid in a below-elbow plaster cast for up to 13 weeks. Displacement of the fragments was assessed independently by two observers using MRI and radiographs performed within two weeks of injury. The MRI assessments showed that only the measurement of sagittal translation of the fragments and an overall assessment of displacement had satisfactory inter- and intra-observer reproducibility and revealed that nine of the 50 fractures were displaced. Only three of the 49 fractures with adequate follow-up failed to unite, and all were displaced with more than 1 mm of translation in the sagittal plane. If the MRI assessment of displacement of the fracture was used as the measurement of choice, assessment of displacement on the initial scaphoid series of radiographs showed a sensitivity of between 33% and 47% and a positive predictive value of between 27% and 86%. Neither observer was able correctly to identify more than 33% to 47% of the displaced fractures from the plain radiographs. Although the overall assessment of displacement and gapping and translation in the coronal plane on the plain radiographs influenced the rate of union, none of these parameters identified all three fractures which failed to unite. We conclude that the assessment of displacement of scaphoid fractures on MRI can probably be used to assess the likelihood of union although the small number of nonunions limits the power of the study. In contrast, the assessment of displacement on routine radiography is inaccurate and of less value in predicting union


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 283 - 289
1 Feb 2022
Cerbasi S Bernasconi A Balato G Dimitri F Zingaretti O Orabona G Pascarella R Mariconda M

Aims

The aims of this study were to assess the pre- and postoperative incidence of deep vein thrombosis (DVT) using routine duplex Doppler ultrasound (DUS), to assess the incidence of pulmonary embolism (PE) using CT angiography, and to identify the factors that predict postoperative DVT in patients with a pelvic and/or acetabular fracture.

Methods

All patients treated surgically for a pelvic and/or acetabular fracture between October 2016 and January 2020 were enrolled into this prospective single-centre study. The demographic, medical, and surgical details of the patients were recorded. DVT screening of the lower limbs was routinely performed using DUS before and at six to ten days after surgery. CT angiography was used in patients who were suspected of having PE. Age-adjusted univariate and stepwise multiple logistic regression analysis were used to determine the association between explanatory variables and postoperative DVT.


Bone & Joint Research
Vol. 3, Issue 3 | Pages 69 - 75
1 Mar 2014
Parsons N Griffin XL Achten J Costa ML

Objectives. To study the measurement properties of a joint specific patient reported outcome measure, a measure of capability and a general health-related quality of life (HRQOL) tool in a large cohort of patients with a hip fracture. Methods. Responsiveness and associations between the Oxford Hip Score (a hip specific measure: OHS), ICEpop CAPability (a measure of capability in older people: ICECAP-O) and EuroQol EQ-5D (general health-related quality of life measure: EQ-5D) were assessed using data available from two large prospective studies. The three outcome measures were assessed concurrently at a number of fixed follow-up time-points in a consecutive sequence of patients, allowing direct assessment of change from baseline, inter-measure associations and validity using a range of statistical methods. Results. ICECAP-O was not responsive to change. EQ-5D was responsive to change from baseline, with an estimated standardised effect size for the two datasets of 0.676 and 0.644 at six weeks and four weeks respectively; this was almost as responsive to change as OHS (1.14 at four weeks). EQ-5D correlated strongly with OHS; Pearson correlation coefficients were 0.74, 0.77 and 0.70 at baseline, four weeks and four months. EQ-5D is a moderately good predictor of death at 12 months following hip fracture. Furthermore, EQ-5D reported by proxies (relatives and carers) behaves similarly to self-reported scores. Conclusions. Our findings suggest that a general HRQOL tool such as EQ-5D could be used to measure outcome for patients recovering from hip fracture, including those with cognitive impairment. Cite this article: Bone Joint Res 2014;3:69–75


The Bone & Joint Journal
Vol. 99-B, Issue 1 | Pages 122 - 127
1 Jan 2017
Weinberg DS Narayanan AS Moore TA Vallier HA

Aims. The best time for definitive orthopaedic care is often unclear in patients with multiple injuries. The objective of this study was make a prospective assessment of the safety of our early appropriate care (EAC) strategy and to evaluate the potential benefit of additional laboratory data to determine readiness for surgery. Patients and Methods. A cohort of 335 patients with fractures of the pelvis, acetabulum, femur, or spine were included. Patients underwent definitive fixation within 36 hours if one of the following three parameters were met: lactate < 4.0 mmol/L; pH ≥ 7.25; or base excess (BE) ≥ -5.5 mmol/L. If all three parameters were met, resuscitation was designated full protocol resuscitation (FPR). If less than all three parameters were met, it was designated an incomplete protocol resuscitation (IPR). Complications were assessed by an independent adjudication committee and included infection; sepsis; PE/DVT; organ failure; pneumonia, and acute respiratory distress syndrome (ARDS). . Results. In total, 66 patients (19.7%) developed 90 complications. An historical cohort of 1441 patients had a complication rate of 22.1%. The complication rate for patients with only one EAC parameter at the point of protocol was 34.3%, which was higher than other groups (p = 0.041). Patients who had IPR did not have significantly more complications (31.8%) than those who had FPR (22.6%; p = 0.078). Regression analysis showed male gender and injury severity score to be independent predictors of complications. Conclusions. This study highlights important trends in the IPR and FPR groups, suggesting that differences in resuscitation parameters may guide care in certain patients; further study is, however, required. We advocate the use of the existing protocol, while research is continued for high-risk subgroups. . Cite this article: Bone Joint J 2017;99-B:122–7


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 456 - 461
1 Mar 2021
Sasaki G Watanabe Y Yasui Y Nishizawa M Saka N Kawano H Miyamoto W

Aims

To clarify the effectiveness of the induced membrane technique (IMT) using beta-tricalcium phosphate (β-TCP) for reconstruction of segmental bone defects by evaluating clinical and radiological outcomes, and the effect of defect size and operated site on surgical outcomes.

Methods

A review of the medical records was conducted of consecutive 35 lower limbs (30 males and five females; median age 46 years (interquartile range (IQR) 40 to 61)) treated with IMT using β-TCP between 2014 and 2018. Lower Extremity Functional Score (LEFS) was examined preoperatively and at final follow-up to clarify patient-centered outcomes. Bone healing was assessed radiologically, and time from the second stage to bone healing was also evaluated. Patients were divided into ≥ 50 mm and < 50 mm defect groups and into femoral reconstruction, tibial reconstruction, and ankle arthrodesis groups.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 3 | Pages 398 - 404
1 Mar 2012
Seide K Aljudaibi M Weinrich N Kowald B Jürgens C Müller J Faschingbauer M

In an interdisciplinary project involving electronic engineers and clinicians, a telemetric system was developed to measure the bending load in a titanium internal femoral fixator. As this was a new device, the main question posed was: what clinically relevant information could be drawn from its application? As a first clinical investigation, 27 patients (24 men, three women) with a mean age of 38.4 years (19 to 66) with femoral nonunions were treated using the system. The mean duration of the nonunion was 15.4 months (5 to 69). The elasticity of the plate-callus system was measured telemetrically until union. Conventional radiographs and a CT scan at 12 weeks were performed routinely, and healing was staged according to the CT scans. All nonunions healed at a mean of 21.5 weeks (13 to 37). Well before any radiological signs of healing could be detected, a substantial decrease in elasticity was recorded. The relative elasticity decreased to 50% at a mean of 7.8 weeks (3.5 to 13) and to 10% at a mean of 19.3 weeks (4.5 to 37). At 12 weeks the mean relative elasticity was 28.1% (0% to 56%). The relative elasticity was significantly different between the different healing stages as determined by the CT scans. Incorporating load measuring electronics into implants is a promising option for the assessment of bone healing. Future application might lead to a reduction in the need for exposure to ionising radiation to monitor fracture healing


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 2 | Pages 239 - 243
1 Mar 2004
Cutler L Molloy A Dhukuram V Bass A

Distal tibial physeal fractures are the second most common growth plate injury and the most common cause of growth arrest and deformity. This study assesses the accuracy of pre-operative planning for placement of the screws in these fractures using either standard radiographs or CT scans. We studied 62 consecutive physeal fractures over a period of four years. An outline of a single cut of the CT scan was used for each patient. An ideal position for the screw was determined as being perpendicular to and at the midpoint of the fracture. The difference in entry point and direction of the screw between the ideal and the observers’ assessments were compared using the paired Student’s t-test. There was a statistically significant improvement (p < 0.0001) in the accuracy of the point of insertion and the direction of the screw on the pre-operative plan when CT scans were used rather than plain radiographs. We would, therefore, recommend that CT scans are routinely used in the pre-operative assessment and treatment of distal tibial physeal fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 1 | Pages 15 - 18
1 Jan 2002
Whelan DB Bhandari M McKee MD Guyatt GH Kreder HJ Stephen D Schemitsch EH

The reliability of the radiological assessment of the healing of tibial fractures remains undetermined. We examined the inter- and intraobserver agreement of the healing of such fractures among four orthopaedic trauma surgeons who, on two separate occasions eight weeks apart, independently assessed the radiographs of 30 patients with fractures of the tibial shaft which had been treated by intramedullary fixation. The radiographs were selected from a database to represent fractures at various stages of healing. For each radiograph, the surgeon scored the degree of union, quantified the number of cortices bridged by callus or with a visible fracture line, described the extent and quality of the callus, and provided an overall rating of healing. The interobserver chance-corrected agreement using a quadratically weighted kappa (κ) statistic in which values of 0.61 to 0.80 represented substantial agreement were as follows: radiological union scale (κ = 0.60); number of cortices bridged by callus (κ = 0.75); number of cortices with a visible fracture line (κ = 0.70); the extent of the callus (κ = 0.57); and general impression of fracture healing (κ = 0.67). The intraobserver agreement of the overall impression of healing (κ = 0.89) and the number of cortices bridged by callus (κ = 0.82) or with a visible fracture line (κ = 0.83) was almost perfect. There are no validated scales which allow surgeons to grade fracture healing radiologically. Among those examined, the number of cortices bridged by bone appears to be a reliable, and easily measured radiological variable to assess the healing of fractures after intramedullary fixation


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 6 | Pages 766 - 771
1 Jun 2009
Brunner A Honigmann P Treumann T Babst R

We evaluated the impact of stereo-visualisation of three-dimensional volume-rendering CT datasets on the inter- and intraobserver reliability assessed by kappa values on the AO/OTA and Neer classifications in the assessment of proximal humeral fractures. Four independent observers classified 40 fractures according to the AO/OTA and Neer classifications using plain radiographs, two-dimensional CT scans and with stereo-visualised three-dimensional volume-rendering reconstructions. Both classification systems showed moderate interobserver reliability with plain radiographs and two-dimensional CT scans. Three-dimensional volume-rendered CT scans improved the interobserver reliability of both systems to good. Intraobserver reliability was moderate for both classifications when assessed by plain radiographs. Stereo visualisation of three-dimensional volume rendering improved intraobserver reliability to good for the AO/OTA method and to excellent for the Neer classification. These data support our opinion that stereo visualisation of three-dimensional volume-rendering datasets is of value when analysing and classifying complex fractures of the proximal humerus


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 12 | Pages 1627 - 1631
1 Dec 2007
Gerdhem P åkesson K

We invited 1604 randomly selected women, all 75 years of age, to participate in a study on the risk factors for fracture. The women were divided into three groups consisting of 1044 (65%) who attended the complete study, 308 (19%) respondents to the study questionnaire only and 252 (16%) who did not respond. The occurrence of the life-time fracture was ascertained from radiological records in all groups and by questionnaires from the attendees and respondents.

According to the radiological records, fewer of the questionnaire respondents (88 of 308, 28.6%) and non-respondents (68 of 252, 27%) had sustained at least one fracture when compared with the attendees (435 of 1044, 41.7%; chi-squared test, p < 0.001). According to the questionnaire, fewer of the respondents (96 of 308, 31.1%) had sustained at least one previous fracture when compared with the attendees (457 of 1044, 43.7%; chi-squared test, p < 0.001).

Any study concerning the risk of fracture may attract those with experience of a fracture which explains the higher previous life-time incidence among the attendees. This factor may cause bias in epidemiological studies.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 4 | Pages 679 - 683
1 Jul 1998
Blundell CM Parker MJ Pryor GA Hopkinson-Woolley J Bhonsle SS

There are a number of classification systems for intracapsular fractures of the proximal femur, but none has been shown to be practical with satisfactory reproducibility and accurate predictive value. We have investigated the AO classification and evaluated intra-and interobserver accuracy and its value in predicting treatment and outcome.

We found it to have very poor intra- and interobserver reliability and to be of limited predictive use for the outcome of treatment. A simplified system in which the subdivisions were allocated to one of three groups of undisplaced, displaced and basal fractures was found to be of value. We conclude that this is the only division which is appropriate for these fractures and that the AO system for intracapsular fractures is too complicated and should not be used.


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 815 - 819
1 Jun 2013
Yadav V Khare GN Singh S Kumaraswamy V Sharma N Rai AK Ramaswamy AG Sharma H

Both conservative and operative forms of treatment have been recommended for patients with a ‘floating shoulder’. We compared the results of conservative and operative treatment in 25 patients with this injury and investigated the use of the glenopolar angle (GPA) as an indicator of the functional outcome. A total of 13 patients (ten male and three female; mean age 32.5 years (24.7 to 40.4)) were treated conservatively and 12 patients (ten male and two female; mean age 33.67 years (24.6 to 42.7)) were treated operatively by fixation of the clavicular fracture alone. Outcome was assessed using the Herscovici score, which was also related to changes in the GPA at one year post-operatively.

The mean Herscovici score was significantly better three months and two years after the injury in the operative group (p < 0.001 and p = 0.003, respectively). There was a negative correlation between the change in GPA and the Herscovici score at two years follow-up in both the conservative and operative groups, but neither were statistically significant (r = -0.295 and r = -0.19, respectively). There was a significant difference between the pre- and post-operative GPA in the operative group (p = 0.017).

When compared with conservative treatment, fixation of the clavicle alone gives better results in the treatment of patients with a floating shoulder. The GPA changes significantly with fixation of clavicle alone but there is no significant correlation between the pre-injury GPA and the final clinical outcome in these patients.

Cite this article: Bone Joint J 2013;95-B:815–19.


Bone & Joint Open
Vol. 4, Issue 9 | Pages 676 - 681
5 Sep 2023
Tabu I Goh EL Appelbe D Parsons N Lekamwasam S Lee J Amphansap T Pandey D Costa M

Aims. The aim of this study was to describe the current pathways of care for patients with a fracture of the hip in five low- and middle-income countries (LMIC) in South Asia (Nepal and Sri Lanka) and Southeast Asia (Malaysia, Thailand, and the Philippines). Methods. The World Health Organization Service Availability and Readiness Assessment tool was used to collect data on the care of hip fractures in Malaysia, Thailand, the Philippines, Sri Lanka, and Nepal. Respondents were asked to provide details about the current pathway of care for patients with hip fracture, including pre-hospital transport, time to admission, time to surgery, and time to weightbearing, along with healthcare professionals involved at different stages of care, information on discharge, and patient follow-up. Results. Responses were received from 98 representative hospitals across the five countries. Most hospitals were publicly funded. There was consistency in clinical pathways of care within country, but considerable variation between countries. Patients mostly travel to hospital via ambulance (both publicly- and privately-funded) or private transport, with only half arriving at hospital within 12 hours of their injury. Access to surgery was variable and time to surgery ranged between one day and more than five days. The majority of hospitals mobilized patients on the first or second day after surgery, but there was notable variation in postoperative weightbearing protocols. Senior medical input was variable and specialist orthogeriatric expertise was unavailable in most hospitals. Conclusion. This study provides the first step in mapping care pathways for patients with hip fracture in LMIC in South Asia. The previous lack of data in these countries hampers efforts to identify quality standards (key performance indicators) that are relevant to each different healthcare system. Cite this article: Bone Jt Open 2023;4(9):676–681