Advertisement for orthosearch.org.uk
Results 1 - 12 of 12
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 6 | Pages 928 - 932
1 Nov 1995
Hutchinson J Neumann L Wallace W

Patients suffering from generalised convulsions may dislocate their shoulders either anteriorly or posteriorly. Those with anterior dislocation are likely to have recurrent episodes because of secondary bony damage to the anterior rim of the glenoid and head of the humerus. In such patients there is high rate of failure of the standard soft-tissue stabilisation procedures. We have therefore devised a bone buttress operation in which autograft or allograft is secured to the deficient anterior glenoid and shaped to form an extension of its articular surface. We report our experience in 14 patients with grandmal epilepsy and recurrent anterior dislocation of the shoulder. After the bone buttress operation there were no further dislocations and all patients were satisfied despite a small restriction in their range of movement. We believe this to be the operation of choice for patients with this difficult problem.


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 2 | Pages 210 - 214
1 Mar 1994
Kilmartin T Barrington R Wallace W

In a survey of 6000 children between 9 and 10 years of age, 122 were found to have unilateral or bilateral hallux valgus. These children were randomly assigned to no treatment or to the use of a foot orthosis. About three years later 93 again had radiography. The metatarsophalangeal joint angle had increased in both groups but more so in the treated group. During the study, hallux valgus developed in the unaffected feet of children with unilateral deformity, despite the use of the orthosis.


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 4 | Pages 585 - 588
1 Jul 1992
Sward L Hughes J Amis A Wallace W

Using 26 cadaver shoulders, we produced a standard defect in the supraspinatus tendon and performed one of three types of repair. Their strength was found by testing in tension the force required to produce a gap of 3 mm, then 6 mm, and finally total disruption of the repair. The use of a polyethylene patch to spread the forces over the lateral bone surface and of extra sutures to grasp the tendon end raised by 2.6 times the load at which a 3 mm gap in the repair occurred and by 1.7 times the load to failure.


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 1 | Pages 111 - 113
1 Jan 1992
Scott B Wallace W Barton M

Four patients with pectoralis major ruptures underwent clinical and dynamometric assessment and one patient underwent late surgical repair. The operation is described. Dynamometry proved a useful and objective method of estimating the loss of strength and indicating patients who might benefit from surgical repair.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 6 | Pages 937 - 940
1 Nov 1991
Kilmartin T Barrington R Wallace W

A survey of 6000 schoolchildren discovered 36 cases of unilateral and 60 cases of bilateral hallux valgus, defined as a metatarsophalangeal angle of more than 14.5 degrees, measured on standing radiographs. Metatarsus primus varus was found not only in the early stages of hallux valgus but in the unaffected feet of children with unilateral hallux valgus. Adduction of the first metatarsal is not due to differential growth of the cortices of the first metatarsal nor is it a consequence of malalignment of the metatarsocuneiform joint. The intermetatarsal angle did not correlate with the angle of metatarsus adductus nor with the intercuneiform angle.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 4 | Pages 647 - 650
1 Jul 1991
Roberts S Foley A Swallow H Wallace W Coughlan D

The articular surface of the humeral head is usually described as facing posteromedially, making an angle of between 16 degrees and 35 degrees with the transepicondylar plane. At hemiarthroplasty the articular surface also appears to be offset posteriorly with respect to the humeral shaft. Coracoid impingement may occur if this offset is not accommodated. An analysis was made of 29 cadaveric humeri using an industrial co-ordinate measuring machine. The position of the centre of the head was defined with respect to the humeral shaft and transepicondylar plane. The humeral articular surface was found to be retroverted by 21.4 degrees and its centre offset posteriorly by 4.7 mm. Previous interpretation of retroversion did not take into account the posterior displacement, and this may be of importance in improving future prosthetic design.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 1 | Pages 180 - 181
1 Jan 1991
Kocialkowski A Wallace W


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 3 | Pages 520 - 520
1 May 1990
Kocialkowski A Wallace W


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 5 | Pages 848 - 850
1 Nov 1989
Bannister G Wallace W Stableforth P Hutson M

In a prospective study, 60 patients with acute acromioclavicular dislocation were randomly allocated to treatment with a broad arm sling or to reduction and fixation with a coracoclavicular screw. Of these 54 were followed for four years. Conservatively-treated patients regained movement significantly more quickly and fully, returned to work and sport earlier and had fewer unsatisfactory results than those having early operation. For severe dislocations, with acromioclavicular displacement of 2 cm or more, early surgery produced better results. Conservative management is best for most acute dislocations, but younger patients with severe displacement may benefit from early reduction and stabilisation.


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 4 | Pages 661 - 663
1 Aug 1989
Charnley R Bickerstaff D Wallace W Stevens A

In a prospective study of the measurement of osteoporosis in patients with fracture of the femoral neck, we compared a histological with a radiological method. We found no significant correlation between histological planimetry and the radiological six metacarpal hand index in patients with either cervical or trochanteric fractures. This demonstrates that metacarpal morphometry cannot predict histological osteoporosis of the iliac crest.


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 5 | Pages 807 - 811
1 Nov 1987
Hoshino A Wallace W

A biomechanical study has been carried out on 20 cadaveric knees to investigate their load-absorbing mechanism. The impact load was applied using a weight falling onto the transected proximal femur and the force transmitted through the knee was measured at the transected distal tibia using a load transducer. The peak force transmitted increased as, sequentially, meniscus, articular cartilage and subchondral bone were damaged or removed. The most striking result was found in an implanted knee replacement where the transmitted force reached 180% of that in the intact knee. The results show that the joint has an impact-absorbing property in each segment and that in the osteoarthritic knee there is less absorption of shock than in the normal knee. The high impact force in an implanted knee suggests that microfractures of the cancellous bone might be expected and may produce loosening.


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 3 | Pages 373 - 377
1 May 1985
Young T Wallace W

This paper reports a prospective study of 72 consecutive patients with fractures or fracture-dislocations of the upper end of the humerus, treated during 1981. Most were elderly and treatment was conservative. Of the 72 patients 64 were followed up for a period of six months. Observations were made on the type of fracture, the speed and pattern of recovery of shoulder movements, on the time of commencement of physiotherapy, and on its duration. We found that with conservative treatment alone, 94% of our patients had good or satisfactory results at six months from injury. The criteria for manipulation are discussed and the literature is reviewed.