Aims. Eccentric
Aims. Abduction bracing is commonly used to treat developmental dysplasia of the hip (DDH) following closed
Aims. To investigate the risk factors for unsuccessful radial head
We describe our early operative experience with a new pelvic
Ultrasound was used to observe the entire course of spontaneous
Aims. Modular dual-mobility (DM) articulations are increasingly used during total hip arthroplasty (THA). However, concerns remain regarding the metal liner modularity. This study aims to correlate metal artifact
Aims. The goal of closed
Aims. To determine the likelihood of achieving a successful closed
Aims. We aimed to compare reoperations following distal radial fractures (DRFs) managed with early fixation versus delayed fixation following initial closed
Aims. Ganz’s studies made it possible to address joint deformities on both the femoral and acetabular side brought about by Perthes’ disease. Femoral head
Objectives. Different criteria for assessing the
Aims. There is no level I evidence dealing with the optimal period of immobilization for patients with a displaced distal radial fracture following closed
Aims. This study aimed to investigate the relationship between changes in patellar height and clinical outcomes at a mean follow-up of 7.7 years (5 to 10) after fixed-bearing posterior-stabilized total knee arthroplasty (PS-TKA). Methods. We retrospectively evaluated knee radiographs of 165 knees, which underwent fixed-bearing PS-TKA with patella resurfacing. The incidence of patella baja and changes in patellar height over a minimum of five years of follow-up were determined using Insall-Salvati ratio (ISR) measurement. We examined whether patella baja (ISR < 0.8) at final follow-up affected clinical outcomes, knee joint range of motion (ROM), and Knee Society Score (KSS). We also assessed inter- and intrarater reliability of ISR measurements and focused on the relationship between patellar height
Aims. Complex joint fractures of the lower extremity are often accompanied by soft-tissue swelling and are associated with prolonged hospitalization and soft-tissue complications. The aim of the study was to evaluate the effect of vascular impulse technology (VIT) on soft-tissue conditioning in comparison with conventional elevation. Methods. A total of 100 patients were included in this prospective, randomized, controlled monocentre study allocated to the three subgroups of dislocated ankle fracture (n = 40), pilon fracture (n = 20), and intra-articular calcaneal fracture (n = 40). Patients were randomized to the two study groups in a 1:1 ratio. The effectiveness of VIT (intervention) compared with elevation (control) was analyzed separately for the whole study population and for the three subgroups. The primary endpoint was the time from admission until operability (in days). Results. The mean length of time until operability was 8.2 days (SD 3.0) in the intervention group and 10.2 days (SD 3.7) in the control group across all three fractures groups combined (p = 0.004). An analysis of the subgroups revealed that a significant
Implant waste during total hip arthroplasty (THA) represents a significant cost to the USA healthcare system. While studies have explored methods to improve THA cost-effectiveness, the literature comparing the proportions of implant waste by intraoperative technology used during THA is limited. The aims of this study were to: 1) examine whether the use of enabling technologies during THA results in a smaller proportion of wasted implants compared to navigation-guided and conventional manual THA; 2) determine the proportion of wasted implants by implant type; and 3) examine the effects of surgeon experience on rates of implant waste by technology used. We identified 104,420 implants either implanted or wasted during 18,329 primary THAs performed on 16,724 patients between January 2018 and June 2022 at our institution. THAs were separated by technology used: robotic-assisted (n = 4,171), imageless navigation (n = 6,887), and manual (n = 7,721). The primary outcome of interest was the rate of implant waste during primary THA.Aims
Methods
Aims. In contrast to operations performed for other fractures, there is a high incidence rate of surgical site infection (SSI) post-open
This study aimed to assess the carbon footprint associated with total hip arthroplasty (THA) in a UK hospital setting, considering various components within the operating theatre. The primary objective was to identify actionable areas for reducing carbon emissions and promoting sustainable orthopaedic practices. Using a life-cycle assessment approach, we conducted a prospective study on ten cemented and ten hybrid THA cases, evaluating carbon emissions from anaesthetic room to recovery. Scope 1 and scope 2 emissions were considered, focusing on direct emissions and energy consumption. Data included detailed assessments of consumables, waste generation, and energy use during surgeries.Aims
Methods
We present our early experience of arthroscopic
reduction of the dislocated hip in very young infants with developmental
dysplasia of the hip (DDH). Eight dislocated hips, which had failed attempts at closed
Aims. There are comparatively few randomized studies evaluating knee arthroplasty prostheses, and fewer still that report longer-term functional outcomes. The aim of this study was to evaluate mid-term outcomes of an existing implant trial cohort to document changing patient function over time following total knee arthroplasty using longitudinal analytical techniques and to determine whether implant design chosen at time of surgery influenced these outcomes. Methods. A mid-term follow-up of the remaining 125 patients from a randomized cohort of total knee arthroplasty patients (initially comprising 212 recruited patients), comparing modern (Triathlon) and traditional (Kinemax) prostheses was undertaken. Functional outcomes were assessed with the Oxford Knee Score (OKS), knee range of movement, pain numerical rating scales, lower limb power output, timed functional assessment battery, and satisfaction survey. Data were linked to earlier assessment timepoints, and analyzed by repeated measures analysis of variance (ANOVA) mixed models, incorporating longitudinal change over all assessment timepoints. Results. The mean follow-up of the 125 patients was 8.12 years (7.3 to 9.4). There was a
Despite limited clinical scientific backing, an additional trochanteric stabilizing plate (TSP) has been advocated when treating unstable trochanteric fractures with a sliding hip screw (SHS). We aimed to explore whether the TSP would result in less post operative fracture motion, compared to SHS alone. Overall, 31 patients with AO/OTA 31-A2 trochanteric fractures were randomized to either a SHS alone or a SHS with an additional TSP. To compare postoperative fracture motion, radiostereometric analysis (RSA) was performed before and after weightbearing, and then at four, eight, 12, 26, and 52 weeks. With the “after weightbearing” images as baseline, we calculated translations and rotations, including shortening and medialization of the femoral shaft.Aims
Methods
Displaced distal radius fractures were investigated at a level 1 major trauma centre during the COVID-19 2020 lockdown due to the implementation of temporary changes in practice. The primary aim was to establish if follow-up at one week in place of the 72-hour British Orthopaedic Association Standards for Trauma & Orthopaedics (BOAST) guidance was safe following manipulation under anaesthetic. A parallel adaptation during lockdown was the non-expectation of Bier’s block. The secondary aim was to compare clinical outcomes with respect to block type. Overall, 90 patients were assessed in a cross-sectional cohort study using a mixed, retrospective-prospective approach. Consecutive sampling of 30 patients pre-lockdown (P1), 30 during lockdown (P2), and 30 during post-lockdown (P3) was applied. Type of block, operative status, follow-up, and complications were extracted. Primary endpoints were early complications (≤ one week). Secondary endpoints were later complications including malunion, delayed union or osteotomy.Aims
Methods
Aims. The aims of this study were to review the surgical technique for a combined femoral head
There is still some controversy about the
Aims. This pilot study aimed to evaluate prospectively the use of inlet
radiographs of the hip as an alternative method of the assessment
of
1. The trends in treatment of cervical dislocation are reviewed. 2. Seventeen patients treated by manual
We performed MRI on 13 infants after operative
We reviewed 98 children (133 hips) with developmental dysplasia of the hip who underwent arthrography immediately after closed
We compared retrospectively consecutive series of patients with cervical dislocation treated at two Australian centres. In Perth, 82 patients were treated by closed
A series of 3061 patients with fracture of the distal tibia or ankle was studied for a possible link between overweight and failed
The treatment of developmental dysplasia of the hip diagnosed after the first year of life remains controversial. A series of 36 children (47 hips), aged between one and 4.9 years underwent gradual closed
1. The radiological appearances of the fragments in 100 trochanteric fractures have been analysed. 2. A simple practical classification enables the correct method of
The efficacy of traction before an attempted closed
A modification of a previously reported one-stage technique for
We have reviewed the serial radiographs of 63 hips in 53 children treated by closed
Aims. Patients with diabetes are at increased risk of wound complications
after open reduction and internal fixation of unstable ankle fractures.
A fibular nail avoids large surgical incisions and allows anatomical
reduction of the mortise. Patients and Methods. We retrospectively reviewed the results of fluoroscopy-guided
reduction and percutaneous fibular nail fixation for unstable Weber
type B or C fractures in 24 adult patients with type 1 or type 2
diabetes. The re-operation rate for wound dehiscence or other indications
such as amputation, mortality and functional outcomes was determined. Results. Two patients developed lateral side wound infection, one of whom
underwent wound debridement. Three other patients required re-operation
for removal of symptomatic hardware. No patient required a below-knee
amputation. Six patients died during the study period for unrelated
reasons. At a median follow-up of 12 months (7 to 38) the mean Short Form-36
Mental Component Score and Physical Component Score were 53.2 (95% confidence
intervals (CI) 48.1 to 58.4) and 39.3 (95% CI 32.1 to 46.4), respectively.
The mean Visual Analogue Score for pain was 3.1 (95% 1.4 to 4.9).
The mean Ankle Osteoarthritis Scale total score was 32.9 (95% CI
16.0 to 49.7). Conclusion. Fluoroscopy-guided
Over a 20-year period we treated 29 patients (31 dislocated hips) by non-operative
This series, albeit consecutive and unselected, is very small; conclusions must therefore be tentative. The results do however suggest that the dangers of late manipulative
We treated 31 intra-articular fractures of the distal radius by arthroscopically-assisted
We present our experience of the modified Dunn
procedure in combination with a Ganz surgical dislocation of the hip
to treat patients with severe slipped capital femoral epiphysis
(SCFE). The aim was to prospectively investigate whether this technique
is safe and reproducible. We assessed the degree of
The different methods described in the literature for the
After late
We have analysed the initial displacement and the retention of position after
We reviewed 110 patients with an unstable fracture of the pelvic ring who had been treated with a trapezoidal external fixator after a mean follow-up of 4.1 years. There were eight open-book (type B1, B3-1) injuries, 62 lateral compression (type B2, B3-2) and 40 rotationally and vertically unstable (type C1-C3) injuries. The rate of complications was high with loss of
Resurfacing arthroplasty of the hip is being used increasingly as an alternative to total hip replacement, especially for young active patients. There is concern about necrosis of the femoral head after resurfacing which can result in fracture and loosening. Most systems use a cemented femoral component, with the potential for thermal necrosis of the cancellous bone of the reamed femoral head. We used thermal probes to record temperatures close to the cement-bone interface during resurfacing arthroplasty. The maximum temperature recorded at the cement-bone interface in four cases was approximately 68°C which was higher than that reported to kill osteocytes. A modified surgical technique using insertion of a suction cannula into the lesser trochanter, generous pulsed lavage and early
We describe a new operative procedure for patients with chronic trochanteric bursitis. Between March 1994 and May 2000, a trochanteric
A classification of Smith's fractures into three types is proposed. It is suggested that the majority of these fractures are caused by a pronation injury. The
We have studied the case records of 16 patients with dislocations of the cervical spine who deteriorated neurologically during or after
We reviewed the management of 100 cases of slipped upper femoral epiphysis treated over a period of 26 years. A total of 14 slips was identified as unstable on admission. These underwent
A consecutive series of 31 displaced fractures of the proximal humerus were randomly selected for treatment either by closed manipulation or by transcutaneous
We used ultrasound to investigate the anatomy and stability of the hip during the phase of joint stabilisation after closed