Advertisement for orthosearch.org.uk
Results 1 - 19 of 19
Results per page:
The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1508 - 1513
1 Nov 2013
Ploegmakers JJW The B Brutty M Ackland TR Wang AW

The aim of this study was to determine the effect of a Galeazzi fracture on the strength of pronation and supination at a mean of two years after surgical treatment. The strength of pronation and supination was measured in varying rotational positions of the forearm of ten male patients (mean age 38.9 years (21 to 64)) who had undergone plate fixation for a Galeazzi fracture. The stability of the distal radioulnar joint was assessed, and a clinical assessment using the quick-Disabilities of the Arm Shoulder and Hand (quickDASH) questionnaire and patient-related wrist examination (PRWE) scores was undertaken. In addition, the strength of pronation and supination was measured in a male control group of 42 healthy volunteers (mean age 21.8 years (18 to 37)). . The mean absolute loss of strength of supination in the injured compared with the non-injured arm throughout all ranges of forearm rotation was 16.1 kg (. sem. 5.3), corresponding to a relative loss of 12.5% (95% confidence interval (CI) 3.6 to 21.4). For the strength of pronation, the mean loss was 19.1 kg (. sem. 4.5), corresponding to a relative loss of 27.2% (95% CI 14.2 to 40.1). Loss of strength of supination following a Galeazzi fracture correlated with poor quickDASH (p = 0.03) and PRWE scores (p < 0.01). Loss of strength of pronation (27.2%), and of supination (12.5%) in particular, after a Galeazzi fracture is associated with worse clinical scores, highlighting the importance of supination of the forearm in function of the upper limb. Cite this article: Bone Joint J 2013;95-B:1508–13


Aims. The aim of this study was to assess and compare active rotation of the forearm in normal subjects after the application of a short-arm cast (SAC) in the semisupination position and a long-arm cast (LAC) in the neutral position. A clinical study was also conducted to compare the functional outcomes of using a SAC in the semisupination position with those of using a LAC in the neutral position in patients who underwent arthroscopic triangular fibrocartilage complex (TFCC) foveal repair. Methods. A total of 40 healthy right-handed volunteers were recruited. Active pronation and supination of the forearm were measured in each subject using a goniometer. In the retrospective clinical study, 40 patients who underwent arthroscopic foveal repair were included. The wrist was immobilized postoperatively using a SAC in the semisupination position (approximately 45°) in 16 patients and a LAC in 24. Clinical outcomes were assessed using grip strength and patient-reported outcomes. The degree of disability caused by cast immobilization was also evaluated when the cast was removed. Results. Supination was significantly more restricted with LACs than with SACs in the semisupination position in male and female patients (p < 0.001 for both). However, pronation was significantly more restricted with SACs in the semisupination position than with LACs in female patients (p = 0.003) and was not significantly different in male patients (p = 0.090). In the clinical study, both groups showed improvement in all parameters with significant differences in grip strength, visual analogue scale scores for pain, modified Mayo Wrist Score, the Disability of the Arm, Shoulder, and Hand (DASH) score, and the Patient-Rated Wrist Evaluation (PRWE) score. No significant postoperative differences were noted between LACs and SACs in the semisupination position. However, the disability caused by immobilization in a cast was significantly higher in patients who had a LAC on the dominant hand (p < 0.001). Conclusion. We found that a SAC in the semisupination position is as effective as a LAC in restricting pronation of the forearm. In addition, postoperative immobilization with a SAC in the semisupination position resulted in comparable pain scores and functional outcomes to immobilization with a LAC after TFCC foveal repair, with less restriction of daily activities. Therefore, we recommend that surgeons consider using a SAC in the semisupination position for postoperative immobilization following TFCC foveal repair for dorsal instability of the distal radioulnar joint. Cite this article: Bone Joint J 2022;104-B(2):249–256


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1498 - 1505
1 Dec 2019
Sonntag J Woythal L Rasmussen P Branner U Hølmer P Jensen AK Lange KHW Brorson S

Aims. The aim of this study was to investigate the difference in functional outcome after repair and non-repair of the pronator quadratus muscle in patients undergoing surgical treatment for a distal radial fracture with volar plating. Patients and Methods. A total of 72 patients with a distal radial fracture were included in this randomized clinical trial. They were allocated to have the pronator quadratus muscle repaired or not, after volar locked plating of a distal radial fracture. The patients, the assessor, the primary investigator, and the statistician were blinded to the allocation. Randomization was irreversibly performed using a web application that guaranteed a secure and tamper-free assignment. The primary outcome measure was the Patient Rated Wrist Evaluation (PRWE) after 12 months. Secondary outcomes included the Disabilities of the Arm, Shoulder and Hand (DASH) score, pronation strength, grip strength, the range of pronation and supination, complications, and the operating time. Results. Of the 72 patients, 63 (87.5%) completed follow-up for the primary outcome measure: 31 (86.1%) from the non-repair group and 32 (88.9%) from the repair group. At the 12-month follow-up, the mean difference in PRWE of 5.47 (95% confidence interval (CI) -4.02 to 14.96) between the repair (mean 18.38 (95% CI 10.34 to 26.41)) and non-repair group (mean 12.90 (95% CI 7.55 to 18.25)) was not statistically significant (p = 0.253). There was a statistically significant difference between pronation strength, favouring non-repair. We found no difference in the other secondary outcomes. Conclusion. We found that repairing pronator quadratus made no difference to the clinical outcome, 12 months after volar plating of a distal radial fracture. We conclude that there is no functional advantage in repairing this muscle under these circumstances and advise against it. Cite this article: Bone Joint J 2019;101-B:1498–1505


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 852 - 859
1 Jul 2019
Reigstad O Holm-Glad T Korslund J Grimsgaard C Thorkildsen R Røkkum M

Aims. Plate and screw fixation has been the standard treatment for painful conditions of the wrist in non-rheumatoid patients in recent decades. We investigated the complications, re-operations, and final outcome in a consecutive series of patients who underwent wrist arthrodesis for non-inflammatory arthritis. Patients and Methods. A total of 76 patients, including 53 men and 23 women, with a mean age of 50 years (21 to 79) underwent wrist arthrodesis. Complications and re-operations were recorded. At a mean follow-up of 11 years (2 to 18), 63 patients completed questionnaires, and 57 attended for clinical and radiological assessment. Results. Of the 76 patients, 46 (60.5%) had complications, resulting in 65 re-operations, mainly related to the plate and screws. In the 63 patients who completed the questionnaires, the mean Quick Disabilities of Arm, Shoulder and Hand (QuickDASH) score was 36 (0 to 91), the mean Patient-Rated Wrist and Hand Evaluation (PRWHE) score was 40 (0 to 96), and 14 patients (22%) reported no wrist pain. Grip strength, pinch strength, and pronation and supination were significantly reduced compared with the contralateral forearm. The outcome was worse in patients who had previously undergone surgery to the wrist, and those with complications. A total of 13 are awaiting further re-operations, giving a total re-operation rate of 63% (40/63). Conclusion. We observed complications and re-operations throughout the follow-up period and therefore consider wrist arthrodesis to be more complicated than previously assumed. Many of the patients never got used to or accepted their stiff wrists and reported a substantial reduction in function and residual pain. Motion-sparing surgery should be offered prior to wrist arthrodesis. Cite this article: Bone Joint J 2019;101-B:852–859


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 874 - 880
1 Jul 2020
Langerhuizen DWG Bergsma M Selles CA Jaarsma RL Goslings JC Schep NWL Doornberg JN

Aims. The aim of this study was to investigate whether intraoperative 3D fluoroscopic imaging outperforms dorsal tangential views in the detection of dorsal cortex screw penetration after volar plating of an intra-articular distal radial fracture, as identified on postoperative CT imaging. Methods. A total of 165 prospectively enrolled patients who underwent volar plating for an intra-articular distal radial fracture were retrospectively evaluated to study three intraoperative imaging protocols: 1) standard 2D fluoroscopic imaging with anteroposterior (AP) and elevated lateral images (n = 55); 2) 2D fluoroscopic imaging with AP, lateral, and dorsal tangential views images (n = 50); and 3) 3D fluoroscopy (n = 60). Multiplanar reconstructions of postoperative CT scans served as the reference standard. Results. In order to detect dorsal screw penetration, the sensitivity of dorsal tangential views was 39% with a negative predictive value (NPV) of 91% and an accuracy of 91%; compared with a sensitivity of 25% for 3D fluoroscopy with a NPV of 93% and an accuracy of 93%. On the postoperative CT scans, we found penetrating screws in: 1) 40% of patients in the 2D fluoroscopy group; 2) in 32% of those in the 2D fluoroscopy group with AP, lateral, and dorsal tangential views; and 3) in 25% of patients in the 3D fluoroscopy group. In all three groups, the second compartment was prone to penetration, while the postoperative incidence decreased when more advanced imaging was used. There were no penetrating screws in the third compartment (extensor pollicis longus groove) in the 3D fluoroscopy groups, and one in the dorsal tangential views group. Conclusion. Advanced intraoperative imaging helps to identify screws which have penetrated the dorsal compartments of the wrist. However, based on diagnostic performance characteristics, one cannot conclude that 3D fluoroscopy outperforms dorsal tangential views when used for this purpose. Dorsal tangential views are sufficiently accurate to detect dorsal screw penetration, and arguably more efficacious than 3D fluoroscopy. Cite this article: Bone Joint J 2020;102-B(7):874–880


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 262 - 267
1 Mar 2024
de Villeneuve Bargemon J Mari R Mathoulin C Prenaud C Merlini L

Aims

Patients with midcarpal instability are difficult to manage. It is a rare condition, and few studies have reported the outcomes of surgical treatment. No prospective or retrospective study has reported the results of arthroscopic palmar capsuloligamentous suturing. Our aim was to report the results of a prospective study of arthroscopic suture of this ligament complex in patients with midcarpal instability.

Methods

This prospective single-centre study was undertaken between March 2012 and May 2022. The primary outcome was to evaluate the functional outcomes of arthroscopic palmar midcarpal suture. The study included 12 patients, eight male and four female, with a mean age of 27.5 years (19 to 42). They were reviewed at three months, six months, and one year postoperatively.


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 307 - 314
1 Mar 2023
de Villeneuve Bargemon J Mathoulin C Jaloux C Levadoux M Gras M Merlini L

Aims

A conventional arthroscopic capsuloligamentous repair is a reliable surgical solution in most patients with scapholunate instability. However, this repair does not seem to be sufficient for more advanced injuries. The aim of this study was to evaluate the functional results of a wide arthroscopic dorsal capsuloligamentous repair (WADCLR) in the management of severe scapholunate instability.

Methods

This was a prospective single-centre study undertaken between March 2019 and May 2021. The primary outcome was the evaluation of the reduction of the radiological deformity and the functional outcomes after WADCLR. A secondary outcome was the evaluation of the effectiveness of this technique in patients with the most severe instability (European Wrist Arthroscopy Society (EWAS) stage 5). The patients were reviewed postoperatively at three, six, and 12 months.


Bone & Joint Open
Vol. 3, Issue 4 | Pages 321 - 331
8 Apr 2022
Dean BJF Srikesavan C Horton R Toye F

Aims

Osteoarthritis (OA) affecting the thumb carpometacarpal joint (CMCJ) is a common painful condition. In this study, we aimed to explore clinicians’ approach to management with a particular focus on the role of specific interventions that will inform the design of future clinical trials.

Methods

We interviewed a purposive sample of 24 clinicians, consisting of 12 surgeons and 12 therapists (four occupational therapists and eight physiotherapists) who managed patients with CMCJ OA. This is a qualitative study using semi-structured, online interviews. Interviews were audio-recorded, transcribed verbatim, and analyzed using thematic analysis.


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 711 - 717
1 Apr 2021
Feitz R van der Oest MJW van der Heijden EPA Slijper HP Selles RW Hovius SER

Aims

Patients with a triangular fibrocartilage complex (TFCC) injury report ulnar-sided wrist pain and impaired function. The surgical procedure of TFCC reinsertion aims to improve function in patients with this injury in whom conservative treatment has failed. The purpose of this study was to investigate the outcomes of open TFCC reinsertion.

Methods

The study involved 274 patients who underwent open repair of the TFCC between December 2013 and December 2018. The patients completed the Patient-Rated Wrist Evaluation (PRWE) questionnaire, and scored pain and function using a visual analogue scale (VAS). Range of motion (ROM) was assessed by experienced hand therapists.


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1386 - 1391
2 Aug 2021
Xiao J Liu B Li L Shi H Wu F

Aims

The primary aim of this study was to assess if traumatic triangular fibrocartilage complex (TFCC) tears can be treated successfully with immobilization alone. Our secondary aims were to identify clinical factors that may predict a poor prognosis.

Methods

This was a retrospective analysis of 89 wrists in 88 patients between January 2015 and January 2019. All patients were managed conservatively initially with either a short-arm or above-elbow custom-moulded thermoplastic splint for six weeks. Outcome measures recorded included a visual analogue scale for pain, Patient-Rated Wrist Evaluation, Disabilities of the Arm, Shoulder and Hand score, and the modified Mayo Wrist Score (MMWS). Patients were considered to have had a poor outcome if their final MMWS was less than 80 points, or if they required eventual surgical intervention. Univariate and logistic regression analyses were used to identify independent predictors for a poor outcome.


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 939 - 945
1 May 2021
Kakar S Logli AL Ramazanian T Gaston RG Fowler JR

Aims

The purpose was to evaluate early clinical, patient-reported, and radiological outcomes of the scapholunate ligament 360° tenodesis (SL 360) technique for treatment of scapholunate (SL) instability.

Methods

We studied the results of nine patients (eight males and one female with a mean age of 44.7 years (26 to 55)) who underwent the SL 360 procedure for reducible SL instability between January 2016 and June 2019, and who were identified from retrospective review of electronic medical records. Final follow-up of any kind was a mean of 33.7 months (12.0 to 51.3). Clinical, radiological, and patient-reported outcome data included visual analogue scale (VAS) for pain, Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH), Mayo Wrist Score (MWS), and Patient-Rated Wrist Examination (PRWE). Means were analyzed using paired t-test.


Aims

To assess the proportion of patients with distal radius fractures (DRFs) who were managed nonoperatively during the COVID-19 pandemic in accordance with the British Orthopaedic Association BOAST COVID-19 guidelines, who would have otherwise been considered for an operative intervention.

Methods

We retrospectively reviewed the radiographs and clinical notes of all patients with DRFs managed nonoperatively, following the publication of the BOAST COVID-19 guidelines on the management of urgent trauma between 26 March and 18 May 2020. Radiological parameters including radial height, radial inclination, intra-articular step-off, and volar tilt from post-reduction or post-application of cast radiographs were measured. The assumption was that if one radiological parameter exceeds the acceptable criteria, the patient would have been considered for an operative intervention in pre-COVID times.


The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 749 - 754
1 Jun 2020
Jung H Park MJ Won Y Lee GY Kim S Lee JS

Aims

The aim of this study was to analyze the association between the shape of the distal radius sigmoid notch and triangular fibrocartilage complex (TFCC) foveal tear.

Methods

Between 2013 and 2018, patients were retrospectively recruited in two different groups. The patient group comprised individuals who underwent arthroscopic transosseous TFCC foveal repair for foveal tear of the wrist. The control group comprised individuals presenting with various diseases around wrist not affecting the TFCC. The study recruited 176 patients (58 patients, 118 controls). The sigmoid notch shape was classified into four types (flat-face, C-, S-, and ski-slope types) and three radiological parameters related to the sigmoid notch (namely, the radius curvature, depth, and version angle) were measured. The association of radiological parameters and sigmoid notch types with the TFCC foveal tear was investigated in univariate and multivariate analyses. Receiver operating characteristic curves were used to estimate a cut-off for any statistically significant variables.


The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1370 - 1376
1 Oct 2015
Jordan RW Saithna A

This article is a systematic review of the published literature about the biomechanics, functional outcome and complications of intramedullary nailing of fractures of the distal radius.

We searched the Medline and EMBASE databases and included all studies which reported the outcome of intramedullary (IM) nailing of fractures of the distal radius. Data about functional outcome, range of movement (ROM), strength and complications, were extracted. The studies included were appraised independently by both authors using a validated quality assessment scale for non-controlled studies and the CONSORT statement for randomised controlled trials (RCTs).

The search strategy revealed 785 studies, of which 16 were included for full paper review. These included three biomechanical studies, eight case series and five randomised controlled trials (RCTs).

The biomechanical studies concluded that IM nails were at least as strong as locking plates. The clinical studies reported that IM nailing gave a comparable ROM, functional outcome and grip strength to other fixation techniques.

However, the mean complication rate of intramedullary nailing was 17.6% (0% to 50%). This is higher than the rates reported in contemporary studies for volar plating. It raises concerns about the role of intramedullary nailing, particularly when comparative studies have failed to show that it has any major advantage over other techniques. Further adequately powered RCTs comparing the technique to both volar plating and percutaneous wire fixation are needed.

Cite this article: Bone Joint J 2015;97-B:1370–6.


The Bone & Joint Journal
Vol. 99-B, Issue 3 | Pages 369 - 375
1 Mar 2017
Ross M Wiemann M Peters SE Benson R Couzens GB

Aims

The aims of this study were: firstly, to investigate the influence of the thickness of cartilage at the sigmoid notch on the inclination of the distal radioulnar joint (DRUJ), and secondly, to compare the sensitivity and specificity of MRI with plain radiographs for the assessment of the inclination of the articular surface of the DRUJ in the coronal plane.

Patients and Methods

Contemporaneous MRI images and radiographs of 100 wrists from 98 asymptomatic patients (mean age 43 years, (16 to 67); 52 male, 53%) with no history of a fracture involving the wrist or surgery to the wrist, were reviewed. The thickness of the cartilage at the sigmoid notch, inclination of the DRUJ and Tolat Type of each DRUJ were determined.


The Bone & Joint Journal
Vol. 96-B, Issue 4 | Pages 508 - 512
1 Apr 2014
van Amerongen EA Creemers LB Kaoui N Bekkers JEJ Kon M Schuurman AH

Damage to the cartilage of the distal radioulnar joint frequently leads to pain and limitation of movement, therefore repair of this joint cartilage would be highly desirable. The purpose of this study was to investigate the fixation of scaffold in cartilage defects of this joint as part of matrix-assisted regenerative autologous cartilage techniques. Two techniques of fixation of collagen scaffolds, one involving fibrin glue alone and one with fibrin glue and sutures, were compared in artificially created cartilage defects of the distal radioulnar joint in a human cadaver. After being subjected to continuous passive rotation, the methods of fixation were evaluated for cover of the defect and pull out force.

No statistically significant differences were found between the two techniques for either cover of the defect or integrity of the scaffold. However, a significantly increased mean pull out force was found for the combined procedure, 0.665 N (0.150 to 1.160) versus 0.242 N (0.060 to 0.730) for glue fixation (p = 0.001).

This suggests that although successful fixation of a collagen type I/III scaffold in a distal radioulnar joint cartilage defect is feasible with both forms of fixation, fixation with glue and sutures is preferable.

Cite this article: Bone Joint J 2014;96-B:508–12.


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1687 - 1696
1 Dec 2013
Nishizuka T Tatebe M Hirata H Shinohara T Yamamoto M Iwatsuki K

The purpose of this study was to evaluate treatment results following arthroscopic triangular fibrocartilage complex (TFCC) debridement for recalcitrant ulnar wrist pain. According to the treatment algorithm, 66 patients (36 men and 30 women with a mean age of 38.1 years (15 to 67)) with recalcitrant ulnar wrist pain were allocated to undergo ulnar shortening osteotomy (USO; n = 24), arthroscopic TFCC repair (n = 15), arthroscopic TFCC debridement (n = 14) or prolonged conservative treatment (n = 13). The mean follow-up was 36.0 months (15 to 54). Significant differences in Hand20 score at 18 months were evident between the USO group and TFCC debridement group (p = 0.003), and between the TFCC repair group and TFCC debridement group (p = 0.029). Within-group comparisons showed that Hand20 score at five months or later and pain score at two months or later were significantly decreased in the USO/TFCC repair groups. In contrast, scores in the TFCC debridement/conservative groups did not decrease significantly. Grip strength at 18 months was significantly improved in the USO/TFCC repair groups, but not in the TFCC debridement/conservative groups. TFCC debridement shows little benefit on the clinical course of recalcitrant ulnar wrist pain even after excluding patients with ulnocarpal abutment or TFCC detachment from the fovea from the indications for arthroscopic TFCC debridement.

Cite this article: Bone Joint J 2013;95-B:1687–96.


The Bone & Joint Journal
Vol. 96-B, Issue 6 | Pages 789 - 794
1 Jun 2014
Sukegawa K Kuniyoshi K Suzuki T Ogawa Y Okamoto S Shibayama M Kobayashi T Takahashi K

We conducted an anatomical study to determine the best technique for transfer of the anterior interosseous nerve (AIN) for the treatment of proximal ulnar nerve injuries. The AIN, ulnar nerve, and associated branches were dissected in 24 cadaver arms. The number of branches of the AIN and length available for transfer were measured. The nerve was divided just proximal to its termination in pronator quadratus and transferred to the ulnar nerve through the shortest available route. Separation of the deep and superficial branches of the ulnar nerve by blunt dissection alone, was also assessed. The mean number of AIN branches was 4.8 (3 to 8) and the mean length of the nerve available for transfer was 72 mm (41 to 106). The transferred nerve reached the ulnar nerve most distally when placed dorsal to flexor digitorum profundus (FDP). We therefore conclude that the AIN should be passed dorsal to FDP, and that the deep and superficial branches of the ulnar nerve require approximately 30 mm of blunt dissection and 20 mm of sharp dissection from the point of bifurcation to the site of the anastomosis.

The use of this technique for transfer of the AIN should improve the outcome for patients with proximal ulnar nerve injuries.

Cite this article: Bone Joint J 2014;96-B:789–94.


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1101 - 1105
1 Aug 2013
Haug LC Glodny B Deml C Lutz M Attal R

Penetration of the dorsal screw when treating distal radius fractures with volar locking plates is an avoidable complication that causes lesions of the extensor tendon in between 2% and 6% of patients. We examined axial fluoroscopic views of the distal end of the radius to observe small amounts of dorsal screw penetration, and determined the ideal angle of inclination of the x-ray beam to the forearm when making this radiological view.

Six volar locking plates were inserted at the wrists of cadavers. The actual screw length was measured under direct vision through a dorsal approach to the distal radius. Axial radiographs were performed for different angles of inclination of the forearm at the elbow.

Comparing axial radiological measurements and real screw length, a statistically significant correlation could be demonstrated at an angle of inclination between 5° and 20°. The ideal angle of inclination required to minimise the risk of implanting over-long screws in a dorsal horizon radiological view is 15°.

Cite this article: Bone Joint J 2013;95-B:1101–5.