Objectives. We aimed to further evaluate the biomechanical characteristics
of two locking screws versus three standard bicortical
screws in synthetic models of normal and
Introduction. The objective of this study was to determine if a synthetic bone
substitute would provide results similar to bone from osteoporotic
femoral heads during in vitro testing with orthopaedic
implants. If the synthetic material could produce results similar
to those of the
The best method of managing a fracture of the
distal humerus in a frail low-demand patient with
The surgical treatment of three- and four-part fractures of the proximal humerus in
Despite limited clinical scientific backing, an additional trochanteric stabilizing plate (TSP) has been advocated when treating unstable trochanteric fractures with a sliding hip screw (SHS). We aimed to explore whether the TSP would result in less post operative fracture motion, compared to SHS alone. Overall, 31 patients with AO/OTA 31-A2 trochanteric fractures were randomized to either a SHS alone or a SHS with an additional TSP. To compare postoperative fracture motion, radiostereometric analysis (RSA) was performed before and after weightbearing, and then at four, eight, 12, 26, and 52 weeks. With the “after weightbearing” images as baseline, we calculated translations and rotations, including shortening and medialization of the femoral shaft.Aims
Methods
Aims. Periprosthetic femoral fractures (PFF) following total hip arthroplasty
(THA) are devastating complications that are associated with functional
limitations and increased overall mortality. Although cementless
implants have been associated with an increased risk of PFF, the
precise contribution of implant geometry and design on the risk
of both intra-operative and post-operative PFF remains poorly investigated.
A systematic review was performed to aggregate all of the PFF literature
with specific attention to the femoral implant used. Patients and Methods. A systematic search strategy of several journal databases and
recent proceedings from the American Academy of Orthopaedic Surgeons
was performed. Clinical articles were included for analysis if sufficient
implant description was provided. All articles were reviewed by
two reviewers. A review of fundamental investigations of implant
load-to-failure was performed, with the intent of identifying similar
conclusions from the clinical and fundamental literature. Results. In total 596 articles were initially identified, with 34 being
eligible for analysis. Aggregate analysis of 1691 PFFs in 342 719
primary THAs revealed a significantly higher number of PFFs with
cementless femoral implants (p <
0.001). Single-wedge and double-wedge
(fit-and-fill) femoral implants were associated with a threefold
increase in PFF rates (p <
0.001) compared with anatomical, fully
coated and tapered/rounded stems. Within cemented stems, loaded-taper
(Exeter) stems were associated with more PFFs than composite-beam
(Charnley) stems (p = 0.004). Review of the fundamental literature
revealed very few studies comparing cementless component designs. Conclusion. Very few studies within the PFF literature provide detailed implant
information. Cementless implants, specifically those of single-wedge
and double-wedge, have the highest PFF rates in the literature,
with most investigations recommending against their use in older
patients with
The aim of this study was to investigate the rate of revision for distal femoral arthroplasty (DFA) performed as a primary procedure for native knee fractures using data from the Australian Orthopaedic Association National Joint Arthroplasty Registry (AOANJRR). Data from the AOANJRR were obtained for DFA performed as primary procedures for native knee fractures from 1 September 1999 to 31 December 2020. Pathological fractures and revision for failed internal fixation were excluded. The five prostheses identified were the Global Modular Arthroplasty System, the Modular Arthroplasty System, the Modular Universal Tumour And Revision System, the Orthopaedic Salvage System, and the Segmental System. Patient demographic data (age, sex, and American Society of Anesthesiologists grade) were obtained, where available. Kaplan-Meier estimates of survival were used to determine the rate of revision, and the reasons for revision and mortality data were examined.Aims
Methods
The aim of this study was to determine the current incidence and epidemiology of humeral diaphyseal fractures. The secondary aim was to explore variation in patient and injury characteristics by fracture location within the humeral diaphysis. Over ten years (2008 to 2017), all adult patients (aged ≥ 16 years) sustaining an acute fracture of the humeral diaphysis managed at the study centre were retrospectively identified from a trauma database. Patient age, sex, medical/social background, injury mechanism, fracture classification, and associated injuries were recorded and analyzed.Aims
Methods
The aim of this study was to determine the immediate post-fixation stability of a distal tibial fracture fixed with an intramedullary nail using a biomechanical model. This was used as a surrogate for immediate weight-bearing postoperatively. The goal was to help inform postoperative protocols. A biomechanical model of distal metaphyseal tibial fractures was created using a fourth-generation composite bone model. Three fracture patterns were tested: spiral, oblique, and multifragmented. Each fracture extended to within 4 cm to 5 cm of the plafond. The models were nearly-anatomically reduced and stabilized with an intramedullary nail and three distal locking screws. Cyclic loading was performed to simulate normal gait. Loading was completed in compression at 3,000 N at 1 Hz for a total of 70,000 cycles. Displacement (shortening, coronal and sagittal angulation) was measured at regular intervals.Aims
Methods
Complex displaced osteoporotic acetabular fractures in the elderly are associated with high levels of morbidity and mortality. Surgical options include either open reduction and internal fixation alone, or combined with total hip arthroplasty (THA). There remains a cohort of severely comorbid patients who are deemed unfit for extensive surgical reconstruction and are treated conservatively. We describe the results of a coned hemipelvis reconstruction and THA inserted via a posterior approach to the hip as the primary treatment for this severely high-risk cohort. We have prospectively monitored a series of 22 cases (21 patients) with a mean follow-up of 32 months (13 to 59).Aims
Methods
The aim of this study was to explore whether time to surgery affects functional outcome in displaced proximal humeral fractures A total of 250 patients presenting within three weeks of sustaining a displaced proximal humeral fracture involving the surgical neck were recruited at 32 acute NHS hospitals in the United Kingdom between September 2008 and April 2011. Of the 125 participants, 109 received surgery (fracture fixation or humeral head replacement) as per randomization. Data were included for 101 and 67 participants at six-month and five-year follow-up, respectively. Oxford Shoulder Scores (OSS) collected at six, 12, and 24 months and at three, four, and five years following randomization was plotted against time to surgery. Long-term recovery was explored by plotting six-month scores against five-year scores and agreement was illustrated with a Bland-Altman plot.Aims
Methods
The aim of this study was to examine trends in the management of fractures of the distal radius in Ireland over a ten-year period, and to determine if there were any changes in response to the English Distal Radius Acute Fracture Fixation Trial (DRAFFT). Data was grouped into annual intervals from 2008 to 2017. All adult inpatient episodes that involved emergency surgery for fractures of the distal radius were includedAims
Patients and Methods
The aim of this study was to evaluate the clinical and radiological outcomes of locking plate fixation, with and without an associated fibular strut allograft, for the treatment of displaced proximal humeral fractures in elderly osteoporotic patients. We undertook a retrospective comparison of two methods of fixation, using a locking plate without an associated fibular strut allograft (LP group) and with a fibular allograft (FA group) for the treatment of these fractures. The outcome was assessed for 52 patients in the LP group and 45 in the FA group, with a mean age of 74.3 years (52 to 89), at a mean follow-up of 14.2 months (12 to 19). The clinical results were evaluated using a visual analogue scale (VAS) score for pain, the Constant score, the American Shoulder and Elbow Surgeons (ASES) score, and the range of movement. Radiological results were evaluated using the neck-shaft angle (NSA) and humeral head height (HHH).Aims
Patients and Methods
Displaced, comminuted acetabular fractures in the elderly are increasingly common, but there is no consensus on whether they should be treated non-surgically, surgically with open reduction and internal fixation (ORIF), or with acute total hip arthroplasty (THA). A combination of ORIF and acute THA, an approach called ’combined hip procedure’ (CHP), has been advocated and our aim was to compare the outcome after CHP or ORIF alone. A total of 27 patients with similar acetabular fractures (severe acetabular impaction with or without concomitant femoral head injury) with a mean age of 72.2 years (50 to 89) were prospectively followed for a minimum of two years. In all, 14 were treated with ORIF alone and 13 were treated with a CHP. Hip joint and patient survival were estimated. Operating times, blood loss, radiological outcomes, and patient-reported outcomes were assessed.Aims
Patients and Methods
Fractures of the distal femur can be challenging to manage and
are on the increase in the elderly osteoporotic population. Management
with casting or bracing can unacceptably limit a patient’s ability
to bear weight, but historically, operative fixation has been associated
with a high rate of re-operation. In this study, we describe the outcomes
of fixation using modern implants within a strategy of early return
to function. All patients treated at our centre with lateral distal femoral
locking plates (LDFLP) between 2009 and 2014 were identified. Fracture
classification and operative information including weight-bearing
status, rates of union, re-operation, failure of implants and mortality
rate, were recorded.Aims
Patients and Methods
The aim of this prospective randomised controlled trial was to
compare non-operative and operative management for acute isolated
displaced fractures of the olecranon in patients aged ≥ 75 years. Patients were randomised to either non-operative management or
operative management with either tension-band wiring or fixation
with a plate. They were reviewed at six weeks, three and six months
and one year after the injury. The primary outcome measure was the
Disabilities of the Arm, Shoulder and Hand (DASH) score at one year.Aims
Patients and Methods
The augmentation of fixation with bone cement
is increasingly being used in the treatment of severe osteoporotic fractures.
We investigated the influence of bone quality on the mechanics of
augmentation of plate fixation in a distal femoral fracture model
(AO 33 A3 type). Eight osteoporotic and eight non-osteoporotic femoral
models were randomly assigned to either an augmented or a non-augmented
group. Fixation was performed using a locking compression plate.
In the augmented group additionally 1 ml of bone cement was injected
into the screw hole before insertion of the screw. Biomechanical
testing was performed in axial sinusoidal loading. Augmentation significantly
reduced the cut-out distance in the osteoporotic models by about
67% (non-augmented mean 0.30 mm ( Cite this article:
Techniques for fixation of fractures of the lateral
malleolus have remained essentially unchanged since the 1960s, but
are associated with complication rates of up to 30%. The fibular
nail is an alternative method of fixation requiring a minimal incision
and tissue dissection, and has the potential to reduce the incidence
of complications. We reviewed the results of 105 patients with unstable fractures
of the ankle that were fixed between 2002 and 2010 using the Acumed
fibular nail. The mean age of the patients was 64.8 years (22 to
95), and 80 (76%) had significant systemic medical comorbidities.
Various different configurations of locking screw were assessed
over the study period as experience was gained with the device.
Nailing without the use of locking screws gave satisfactory stability
in only 66% of cases (4 of 6). Initial locking screw constructs
rendered between 91% (10 of 11) and 96% (23 of 24) of ankles stable.
Overall, seven patients had loss of fixation of the fracture and
there were five post-operative wound infections related to the distal
fibula. This lead to the development of the current technique with
a screw across the syndesmosis in addition to a distal locking screw.
In 21 patients treated with this technique there have been no significant
complications and only one superficial wound infection. Good fracture
reduction was achieved in all of these patients. The mean physical
component Short-Form 12, Olerud and Molander score, and American Academy
of Orthopaedic Surgeons Foot and Ankle outcome scores at a mean
of six years post-injury were 46 (28 to 61), 65 (35 to 100) and
83 (52 to 99), respectively. There have been no cases of fibular
nonunion. Nailing of the fibula using our current technique gives good
radiological and functional outcomes with minimal complications,
and should be considered in the management of patients with an unstable
ankle fracture.
It is becoming increasingly common for a patient
to have ipsilateral hip and knee replacements. The inter-prosthetic (IP)
distance, the distance between the tips of hip and knee prostheses,
has been thought to be associated with an increased risk of IP fracture.
Small gap distances are generally assumed to act as stress risers,
although there is no real biomechanical evidence to support this. The purpose of this study was to evaluate the influence of IP
distance, cortical thickness and bone mineral density on the likelihood
of an IP femoral fracture. A total of 18 human femur specimens were randomised into three
groups by bone density and cortical thickness. For each group, a
defined IP distance of 35 mm, 80 mm or 160 mm was created by choosing
the appropriate lengths of component. The maximum fracture strength
was determined using a four-point bending test. The fracture force of all three groups was similar (p = 0.498).
There was a highly significant correlation between the cortical
area and the fracture strength (r = 0.804, p <
0.001), whereas
bone density showed no influence. This study suggests that the IP distance has little influence
on fracture strength in IP femoral fractures: the thickness of the
cortex seems to be the decisive factor. Cite this article:
Secure fixation of displaced proximal fractures of the humerus is a challenging problem. A total of 32 patients with acutely displaced three- or four-part proximal fractures of the humerus were treated by open reduction and internal fixation using the proximal humeral internal locking system (PHILOS) plate. There were 23 women and nine men with a mean age of 59.9 years (18 to 87). Data were collected prospectively and the outcomes were assessed using the Constant score. The mean follow-up was for 11 months (3 to 24). In 31 patients (97%) the fracture united clinically and radiologically at a mean of 10 weeks (8 to 24). The mean Constant score at final review was 66.5 (30 to 92). There was no significant difference in outcome when comparing patients aged more than 60 years (18 patients) with those aged less than 60 years (14 patients) ( This plate provides an alternative method of fixation for fractures of the proximal humerus. It provides a stable fixation in young patients with good-quality bone sufficient to permit early mobilisation. Failure of the screws to maintain fixation in the elderly remains a problem.
The National Institute for Health and Clinical
Excellence (NICE) guidelines from 2011 recommend the use of cemented
hemi-arthroplasty for appropriate patients with an intracapsular
hip fracture. In our institution all patients who were admitted
with an intracapsular hip fracture and were suitable for a hemi-arthroplasty
between April 2010 and July 2012 received an uncemented prosthesis
according to our established departmental routine practice. A retrospective
analysis of outcome was performed to establish whether the continued
use of an uncemented stem was justified. Patient, surgical and outcome
data were collected on the National Hip Fracture database. A total
of 306 patients received a Cathcart modular head on a Corail uncemented
stem as a hemi-arthroplasty. The mean age of the patients was 83.3
years ( Cite this article:
We have managed 21 patients with a fracture of the tibia complicated by bone and soft-tissue loss as a result of an open fracture in 10, or following debridement of an infected nonunion in 11, by resection of all the devitalised tissues, acute limb shortening to close the defect, application of an external fixator and metaphyseal osteotomy for re-lengthening. The mean bone loss was 4.7 cm (3 to 11). The mean age of the patients was 28.8 years (12 to 54) and the mean follow-up was 34.8 months (24 to 75). All the fractures united with a well-aligned limb. The mean duration of treatment for the ten grade-III A+B open fractures (according to the Gustilo-Anderson classification) was 5.7 months (4.5 to 8) and for the nonunions, 7.6 months (5.5 to 12.5). Complications included one refracture, one transient palsy of the peroneal nerve and one equinus contracture of 10°.
We investigated a new intramedullary locking
nail that allows the distal interlocking screws to be locked to
the nail. We compared fixation using this new implant with fixation
using either a conventional nail or a locking plate in a laboratory
simulation of an osteoporotic fracture of the distal femur. A total
of 15 human cadaver femora were used to simulate an AO 33-A3 fracture
pattern. Paired specimens compared fixation using either a locking
or non-locking retrograde nail, and using either a locking retrograde
nail or a locking plate. The constructs underwent cyclical loading
to simulate single-leg stance up to 125 000 cycles. Axial and torsional
stiffness and displacement, cycles to failure and modes of failure
were recorded for each specimen. When compared with locking plate
constructs, locking nail constructs had significantly longer mean
fatigue life (75 800 cycles ( The new locking retrograde femoral nail showed better stiffness
and fatigue life than locking plates, and superior fatigue life
to non-locking nails, which may be advantageous in elderly patients. Cite this article:
Our aim in this pilot study was to evaluate the fixation of, the bone remodelling around, and the clinical outcome after surgery of a new, uncemented, fully hydroxyapatite-coated, collared and tapered femoral component, designed specifically for elderly patients with a fracture of the femoral neck. We enrolled 50 patients, of at least 70 years of age, with an acute displaced fracture of the femoral neck in this prospective single-series study. They received a total hip replacement using the new component and were followed up regularly for two years. Fixation was evaluated by radiostereometric analysis and bone remodelling by dual-energy x-ray absorptiometry. Hip function and the health-related quality of life were assessed using the Harris hip score and the EuroQol-5D. Up to six weeks post-operatively there was a mean subsidence of 0.2 mm (−2.1 to +0.5) and a retroversion of a mean of 1.2° (−8.2° to +1.5°). No component migrated after three months. The patients had a continuous loss of peri-prosthetic bone which amounted to a mean of 16% (−49% to +10%) at two years. The mean Harris hip score was 82 (51 to 100) after two years. The two-year results from this pilot study indicate that this new, uncemented femoral component can be used for elderly patients with osteoporotic fractures of the femoral neck.
We investigated the static and cyclical strength of parallel and angulated locking plate screws using rigid polyurethane foam (0.32 g/cm3) and bovine cancellous bone blocks. Custom-made stainless steel plates with two conically threaded screw holes with different angulations (parallel, 10° and 20° divergent) and 5 mm self-tapping locking screws underwent pull-out and cyclical pull and bending tests. The bovine cancellous blocks were only subjected to static pull-out testing. We also performed finite element analysis for the static pull-out test of the parallel and 20° configurations. In both the foam model and the bovine cancellous bone we found the significantly highest pull-out force for the parallel constructs. In the finite element analysis there was a 47% more damage in the 20° divergent constructs than in the parallel configuration. Under cyclical loading, the mean number of cycles to failure was significantly higher for the parallel group, followed by the 10° and 20° divergent configurations. In our laboratory setting we clearly showed the biomechanical disadvantage of a diverging locking screw angle under static and cyclical loading.
We examined prospectively collected data from 6782 consecutive hip fractures and identified 327 fractures in 315 women aged ≤65 years. We report on their demographic characteristics, treatment and outcome and compare them with a cohort of 4810 hip fractures in 4542 women aged >
65 years. The first significant increase in age-related incidence of hip fracture was at 45, rather than 50, which is when screening by the osteoporosis service starts in most health areas. Hip fractures in younger women are sustained by a population at risk as a result of underlying disease. Mortality of younger women with hip fracture was 46 times the background mortality of the female population. Smoking had a strong influence on the relative risk of ‘early’ (≤ 65 years of age) fracture. Lag screw fixation was the most common method of operative treatment. General complication rates were low, as were re-operation rates for cemented prostheses. Kaplan-Meier implant survivorship of displaced intracapsular fractures treated by reduction and lag screw fixation was 71% (95% confidence interval 56 to 81) at five years. The best form of treatment remains controversial.
A single antegrade Rush nail was used to treat 37 fractures of the distal humerus extending to the olecranon fossa and up to 6.5 cm proximal to it. In order to stabilise the fracture, the bent tip of the Rush nail was directed into the lateral epicondylar ridge. This gave immediate stability. All the fractures united without residual stiffness of the shoulder or elbow.
We studied the epidemiology of 401 fractures of the shaft of the humerus in 397 patients aged 16 years or older. The incidence was 14.5 per 100 000 per year with a gradually increasing age-specific incidence from the fifth decade, reaching almost 60 per 100 000 per year in the ninth decade. Most were closed fractures in elderly patients which had been sustained as the result of a simple fall. The age distribution in women was characterised by a peak in the eighth decade while that in men was more even. Simple fractures were by far the most common and most were located in the middle or proximal shaft. The incidence of palsy of the radial nerve was 8% and fractures in the middle and distal shaft were most likely to be responsible. Only 2% of the fractures were open and 8% were pathological. These figures are representative of a population with a low incidence of high-energy and penetrating trauma, which probably reflects the situation in most European countries.
Between 2000 and 2006 we performed salvage tibiotalar arthrodesis in 17 diabetic patients (17 ankles) with grossly unstable ankles caused by bimalleolar fractures complicated by Charcot neuro-arthropathy. There were ten women and seven men with a mean age of 61.6 years (57 to 69). A crossed-screw technique was used. Two screws were used in eight patients and three screws in nine. Additional graft from the malleoli was used in all patients. The mean follow-up was 26 months (12 to 48) and the mean time to union was 5.8 months (4 to 8). A stable ankle was achieved in 14 patients (82.4%), nine of whom had bony fusion and five had a stiff fibrous union. The results were significantly better in underweight patients, in those in whom surgery had been performed three to six months after the onset of acute Charcot arthropathy, in those who had received anti-resorptive medication during the acute stage, in those without extensive peripheral neuropathy, and in those with adequate peripheral oxygen saturation (>
95%). The arthrodesis failed because of avascular necrosis of the talus in only three patients (17.6%), who developed grossly unstable, ulcerated hindfeet, and required below-knee amputation.