Advertisement for orthosearch.org.uk
Results 1 - 8 of 8
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 899 - 905
1 Jul 2008
Dias JJ Dhukaram V Abhinav A Bhowal B Wildin CJ

We report the outcome at a mean of 93 months (73 to 110) of 71 patients with an acute fracture of the scaphoid who were randomised to Herbert screw fixation (35) or below-elbow plaster cast immobilisation (36). These 71 patients represent the majority of a randomised series of 88 patients whose short-term outcome has previously been reported. Those patients available for later review were similar in age, gender and hand dominance. There was no statistical difference in symptoms and disability as assessed by the mean Patient Evaluation Measure (p = 0.4), or mean Patient-Rated Wrist Evaluation (p = 0.9), the mean range of movement of the wrist (p = 0.4), mean grip strength (p = 0.8), or mean pinch strength (p = 0.4). Radiographs were available from the final review for 59 patients. Osteoarthritic changes were seen in the scaphotrapezial and radioscaphoid joints in eight (13.5%) and six patients (10.2%), respectively. Three patients had asymptomatic lucency surrounding the screw. One non-operatively treated patient developed nonunion with avascular necrosis. In five patients who were treated non-operatively (16%) there was an abnormal scapholunate angle ( > 60°), but in four of these patients this finding was asymptomatic. No medium-term difference in function or radiological outcome was identified between the two treatment groups


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 499 - 503
1 Apr 2009
Kircher J Patzer T Magosch P Lichtenberg S Habermeyer P

We describe the outcome at a mean follow-up of 8.75 years (7.6 to 9.8) of seven patients who had undergone osteochondral autologous transplantation for full-thickness cartilage defects of the shoulder between 1998 and 2000. These patients have been described previously at a mean of 32.6 months when eight were included. One patient has been lost to follow-up. The outcome was assessed by the Constant shoulder score and the Lysholm knee score to assess any donor-site morbidity. Standard radiographs and MR scores were obtained and compared with the pre-operative findings and the results from the previous review. No patient required any further surgery on the shoulder. The mean Constant score improved significantly until the final follow-up (p = 0.018). The Lysholm score remained excellent throughout. There was a significant progression of osteoarthritic changes from the initial surgery to the first and final follow-up but this did not appear to be related to the size of the defect, the number of cylinders required or the Constant score (p = 0.016). MRI showed that all except one patient had a congruent joint surface at the defect with full bony integration of all osteochondral cylinders. The results have remained satisfactory over a longer period with very good objective and subjective findings


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 5 | Pages 761 - 766
1 Sep 1996
Aoki M Okamura K Fukushima S Takahashi T Ogino T

We treated 12 shoulders in ten patients with irreparable rotator-cuff tears by transfer of the latissimus dorsi. There were nine men and one woman. Their average age was 64.0 years and the average follow-up was 35.6 months (26 to 42). The results were excellent in four shoulders, good in four, fair in one, and poor in three. Active forward flexion improved from a preoperative average of 99° to a postoperative average of 135°. Osteoarthritic changes appeared in five shoulders and proximal migration of the humeral head progressed in six. EMG revealed that nine of the 12 transferred muscles showed activity which was synergistic with the supraspinatus on external rotation with abduction. We conclude that latissimus dorsi transfer can be effective in restoring shoulder function after massive irreparable tears of the rotator cuff


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 7 | Pages 991 - 997
1 Sep 2004
Scheibel M Bartl C Magosch P Lichtenberg S Habermeyer P

We performed eight osteochondral autologous transplantations from the knee joint to the shoulder. All patients (six men, two women; mean age 43.1 years) were documented prospectively. In each patient the stage of the osteochondral lesion was Outerbridge grade IV with a mean size of the affected area of 150 mm. 2. All patients were assessed by using the Constant score for the shoulder and the Lysholm score for the knee. Standard radiographs, magnetic resonance imaging and second-look arthroscopy were used to assess the presence of glenohumeral osteoarthritis and the integrity of the grafts. After a mean of 32.6 months (8 to 47), the mean Constant score increased significantly. Magnetic resonance imaging revealed good osseointegration of the osteochondral plugs and congruent articular cartilage at the transplantation site in all but one patient. Second-look arthroscopy performed in two cases revealed a macroscopically good integration of the autograft with an intact articular surface. Osteochondral autologous transplantation in the shoulder appears to offer good clinical results for treating full-thickness osteochondral lesions of the glenohumeral joint. However, our study suggests that the development of osteoarthritis and the progression of pre-existing osteoarthritic changes cannot be altered by this technique


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 2 | Pages 200 - 202
1 Feb 2008
Gupta RK Singh H Sandhu VPS

We describe a method for stabilising the distal radioulnar joint using a double breasted slip of extensor retinaculum.

This is a retrospective series of 30 patients with a painful wrist secondary to instability of the distal radioulnar joint. The results were assessed by a modified Mayo Score. The mean follow-up was for 38.1 months (13 months to 8 years).

Twelve patients had excellent, 16 good and 2 fair outcomes. One patient had experienced temporary numbness in the distribution of the dorsal branch of the ulnar nerve. The modified Mayo wrist score increased from a pre-operative mean of 23.89 (10 to 50) to a final mean of 94.4 (85 to 100).

Stabilisation of the distal radioulnar joint by the method of using a double breasted slip of the extensor retinaculum gives satisfactory results. The procedure is simple and reproducible.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 10 | Pages 1329 - 1335
1 Oct 2007
Lunn JV Castellanos-Rosas J Walch G

We retrospectively identified 18 consecutive patients with synovial chrondromatosis of the shoulder who had arthroscopic treatment between 1989 and 2004. Of these, 15 were available for review at a mean follow-up of 5.3 years (2.3 to 16.5). There were seven patients with primary synovial chondromatosis, but for the remainder, the condition was a result of secondary causes. The mean Constant score showed that pain and activities of daily living were the most affected categories, being only 57% and 65% of the values of the normal side. Surgery resulted in a significant improvement in the mean Constant score in these domains from 8.9 (4 to 15) to 11.3 (2 to 15) and from 12.9 (5 to 20) to 18.7 (11 to 20), respectively (unpaired t-test, p = 0.04 and p < 0.0001, respectively). Movement and strength were not significantly affected. Osteoarthritis was present in eight patients at presentation and in 11 at the final review. Recurrence of the disease with new loose bodies occurred in two patients from the primary group at an interval of three and 12 years post-operatively. In nine patients, loose bodies were also present in the bicipital groove; seven of these underwent an open bicipital debridement and tenodesis.

We found that arthroscopic debridement of the glenohumeral joint and open debridement and tenodesis of the long head of biceps, when indicated, are safe and effective in relieving symptoms at medium-term review.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 2 | Pages 208 - 212
1 Feb 2006
Habermeyer P Magosch P Rudolph T Lichtenberg S Liem D

We describe 14 patients who underwent transfer of latissimus dorsi using a new technique through a single-incision. Their mean age was 61 years (47 to 76) and the mean follow-up was 32 months (19 to 42).

The mean Constant score improved from 46.5 to 74.6 points. The mean active flexion increased from 119° to 170°, mean abduction from 118° to 169° and mean external rotation from 19° to 33°. The Hornblower sign remained positive in three patients (23%) as did the external rotation lag sign also in three patients (23%). No patient had a positive drop-arm sign at follow-up. No significant difference was noted between the mean pre- and postoperative acromiohumeral distance as seen on radiographs. An increased grade of osteoarthritis was found in three patients (23%). Electromyographic analysis showed activity of the transferred muscle in all patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 760 - 764
1 Jun 2006
Dotzis A Cochu G Mabit C Charissoux JL Arnaud JP

Excision is not a suitable treatment for all comminuted fractures of the radial head. In elbows where instability can be predicted, a replacement arthroplasty of the radial head is more effective. The aim of this paper was to present the medium-term results of the Judet floating radial head prosthesis.

This operation was performed on 14 patients between 1992 and 2003, of whom 12 were reviewed at a mean follow-up of five years and three months (1 to 12 years). The outcome was assessed using the Mayo elbow performance score and a modified Disability of Arm Shoulder Hand (DASH) questionnaire. There were six excellent results, four good, one fair and one poor, as graded by the Mayo score. The mean DASH score was 23.9/100 (0 to 65.8/100). The only significant complication occurred in one patient who developed a severe complex regional pain syndrome. There were no patients with secondary instability of the elbow, implant loosening, cubitus valgus, osteoporosis of the capitellum, or pain in the forearm and wrist. Our experience, combined with that of other authors using this device, has encouraged us to continue using the Judet prosthesis in comminuted fractures of the elbow where instability is a potential problem.