Advertisement for orthosearch.org.uk
Results 1 - 50 of 75
Results per page:
The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 867 - 871
1 Jul 2019
Wilcox M Brown H Johnson K Sinisi M Quick TJ

Aims. Improvements in the evaluation of outcomes following peripheral nerve injury are needed. Recent studies have identified muscle fatigue as an inevitable consequence of muscle reinnervation. This study aimed to quantify and characterize muscle fatigue within a standardized surgical model of muscle reinnervation. Patients and Methods. This retrospective cohort study included 12 patients who underwent Oberlin nerve transfer in an attempt to restore flexion of the elbow following brachial plexus injury. There were ten men and two women with a mean age of 45.5 years (27 to 69). The mean follow-up was 58 months (28 to 100). Repeated and sustained isometric contractions of the elbow flexors were used to assess fatigability of reinnervated muscle. The strength of elbow flexion was measured using a static dynamometer (KgF) and surface electromyography (sEMG). Recordings were used to quantify and characterize fatigability of the reinnervated elbow flexor muscles compared with the uninjured contralateral side. Results. The mean peak force of elbow flexion was 7.88 KgF (. sd. 3.80) compared with 20.65 KgF (. sd . 6.88) on the contralateral side (p < 0.001). Reinnervated elbow flexor muscles (biceps brachialis) showed sEMG evidence of fatigue earlier than normal controls with sustained (60-second) isometric contraction. Reinnervated elbow flexor muscles also showed a trend towards a faster twitch muscle fibre type. Conclusion. The assessment of motor outcomes must involve more than peak force alone. Reinnervated muscle shows a shift towards fast twitch fibres following reinnervation with an earlier onset of fatigue. Our findings suggest that fatigue is a clinically relevant characteristic of reinnervated muscle. Adoption of these metrics into clinical practice and the assessment of outcome could allow a more meaningful comparison to be made between differing forms of treatment and encourage advances in the management of motor recovery following nerve transfer. Cite this article: Bone Joint J 2019;101-B:867–871


The Bone & Joint Journal
Vol. 98-B, Issue 11 | Pages 1517 - 1520
1 Nov 2016
Quick TJ Singh AK Fox M Sinisi M MacQuillan A

Aims. Improvements in the evaluation of outcome after nerve transfers are required. The assessment of force using the Medical Research Council (MRC) grades (0 to 5) is not suitable for this purpose. A ceiling effect is encountered within MRC grade 4/5 rendering this tool insensitive. Our aim was to show how the strength of flexion of the elbow could be assessed in patients who have undergone a re-innervation procedure using a continuous measurement scale. Methods. A total of 26 patients, 23 men and three women, with a mean age of 37.3 years (16 to 66), at the time of presentation, attended for review from a cohort of 52 patients who had undergone surgery to restore flexion of the elbow after a brachial plexus injury and were included in this retrospective study. The mean follow-up after nerve transfer was 56 months (28 to 101, standard deviation (. sd. ) 20.79). The strength of flexion of the elbow was measured in a standard outpatient environment with a static dynamometer. Results. In total, 21 patients (81%) gained MRC grade 4 strength of flexion of the elbow. The mean force of flexion was 7.2 kgf (3 to 15.5, . sd. 3.3). Conclusion. This study establishes that the dynamometer may be used for assessing the strength of flexion of the elbow in the outpatient department after nerve reconstructive surgery. Cite this article: Bone Joint J 2016;98-B:1517–20


The Bone & Joint Journal
Vol. 98-B, Issue 2 | Pages 209 - 217
1 Feb 2016
Satbhai NG Doi K Hattori Y Sakamoto S

Aims

Between 2002 and 2011, 81 patients with a traumatic total brachial plexus injury underwent reconstruction by double free muscle transfer (DFMT, 47 cases), single muscle transfer (SMT, 16 cases) or nerve transfers (NT, 18 cases).

Methods

They were evaluated for functional outcome and quality of life (QoL) using the Disability of Arm, Shoulder and Hand questionnaire, both pre- and post-operatively. The three groups were compared and followed-up for at least 24 months.


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1284 - 1291
1 Jul 2021
Carter TH Karunaratne BJ Oliver WM Murray IR White TO Reid JT Duckworth AD

Aims. Acute distal biceps tendon repair reduces fatigue-related pain and minimizes loss of supination of the forearm and strength of flexion of the elbow. We report the short- and long-term outcome following repair using fixation with a cortical button techqniue. Methods. Between October 2010 and July 2018, 102 patients with a mean age of 43 years (19 to 67), including 101 males, underwent distal biceps tendon repair less than six weeks after the injury, using cortical button fixation. The primary short-term outcome measure was the rate of complications. The primary long-term outcome measure was the abbreviated Disabilities of the Arm, Shoulder and Hand (QuickDASH) score. Secondary outcomes included the Oxford Elbow Score (OES), EuroQol five-dimension three-level score (EQ-5D-3L), satisfaction, and return to function. Results. Eight patients (7.8%) had a major complication and 34 (33.3%) had a minor complication. Major complications included re-rupture (n = 3; 2.9%), unrecovered nerve injury (n = 4; 3.9%), and surgery for heterotopic ossification (n = 1; 1.0%). Three patients (2.9%) overall required further surgery for a complication. Minor complications included neurapraxia (n = 27; 26.5%) and superficial infection (n = 7; 6.9%). A total of 33 nerve injuries occurred in 31 patients (30.4%). At a mean follow-up of five years (1 to 9.8) outcomes were available for 86 patients (84.3%). The median QuickDASH, OES, EQ-5D-3L, and satisfaction scores were 1.2 (IQR 0 to 5.1), 48 (IQR 46 to 48), 0.80 (IQR 0.72 to 1.0), and 100/100 (IQR 90 to 100), respectively. Most patients were able to return to work (81/83, 97.6%) and sport (51/62,82.3%). Unrecovered nerve injury was associated with an inferior outcome according to the QuickDASH (p = 0.005), OES (p = 0.004), EQ-5D-3L (p = 0.010), and satisfaction (p = 0.024). Multiple linear regression analysis identified an unrecovered nerve injury to be strongly associated with an inferior outcome according to the QuickDASH score (p < 0.001), along with infection (p < 0.001), although re-rupture (p = 0.440) and further surgery (p = 0.652) were not. Conclusion. Acute distal biceps tendon repair using cortical button fixation was found to result in excellent patient-reported outcomes and health-related quality of life. Although rare, unrecovered nerve injury adversely affects outcome. Cite this article: Bone Joint J 2021;103-B(7):1284–1291


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1301 - 1305
1 Nov 2024
Prajapati A Thakur RPS Gulia A Puri A

Aims. Reconstruction after osteoarticular resection of the proximal ulna for tumours is technically difficult and little has been written about the options that are available. We report a series of four patients who underwent radial neck to humeral trochlea transposition arthroplasty following proximal ulnar osteoarticular resection. Methods. Between July 2020 and July 2022, four patients with primary bone tumours of the ulna underwent radial neck to humeral trochlea transposition arthroplasty. Their mean age was 28 years (12 to 41). The functional outcome was assessed using the range of motion (ROM) of the elbow, rotation of the forearm and stability of the elbow, the Musculoskeletal Tumor Society score (MSTS), and the nine-item abbreviated version of the Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH-9) score. Results. All patients were available for follow-up at a mean of 33 months (25 to 43) and were disease-free. The mean flexion arc was 0° to 105°. Three patients had complications. One had neuropraxia of the ulnar nerve. The symptoms resolved after three months. In one patient, the screw used for fixation of the triceps tendon became exposed and was removed, six months postoperatively. One patient with wound dehiscence required a local flap for soft-tissue cover, four months postoperatively. At a mean follow-up of 33 months (25 to 43), the mean flexion arc was 0° to 105°. All patients had full supination (85°) but none had any pronation. The mean MSTS score was 23.5 (23 to 24) and mean QuickDASH-9 score was 26.13 (16.5 to 35.75). Three patients had varus-valgus instability on examination, although only one had a sense of instability while working. Conclusion. Radial neck to humeral trochlea transposition offers a satisfactory and cost-effective biological reconstructive option after osteoarticular resection of the proximal ulna, in the short term. It provides good elbow function and, being a biological reconstruction option using native bone, is likely to provide long-term stability and durability. Cite this article: Bone Joint J 2024;106-B(11):1301–1305


The Bone & Joint Journal
Vol. 98-B, Issue 11 | Pages 1505 - 1509
1 Nov 2016
Kong BY Kim SH Kim DH Joung HY Jang YH Oh JH

Aims. Our aim was to describe the atypical pattern of increased fatty degeneration in the infraspinatus muscle compared with the supraspinatus in patients with a massive rotator cuff tear. We also wished to describe the nerve conduction and electromyography findings in these patients. Patients and Methods. A cohort of patients undergoing surgery for a massive rotator cuff tear was identified and their clinical records obtained. Their MRI images were reviewed to ascertain the degree of retraction of the torn infraspinatus and supraspinatus muscles, and the degree of fatty degeneration in both muscles was recorded. Nerve conduction studies were also performed in those patients who showed more degeneration in the infraspinatus than in the supraspinatus. Results. Out of a total of 396 patients who underwent surgery for a massive rotator cuff tear between 2006 and 2015, 35 who had more severe fatty degeneration in the infraspinatus than in the supraspinatus were identified. There were 13 men and 22 women. Their mean age was 67.2 years (56 to 81). A total of 20 (57%) had grade 4 fatty degeneration as classified by Fuchs et al, in the infraspinatus. Patte grade 3 muscle retraction was seen in 25 patients (71%). In all, eight patients (23%) had abnormal nerve conduction studies. The mean retraction of the infraspinatus was 3.6 cm (2.1 to 4.8) in patients with more severe fatty degeneration in the infraspinatus, versus 3.0 cm (1.7 to 5.5) in those with more severe degeneration in the supraspinatus (p = 0.003). The retraction ratios were 0.98 (0.61 to 1.57) and 0.77 (0.38 to 1.92), respectively (p < 0.001). Conclusion. Fatty degeneration affecting the infraspinatus more than the supraspinatus may be, in the context of a massive rotator cuff tear, due to entrapment of the suprascapular nerve at the spinoglenoid notch. Cite this article: Bone Joint J 2016;98-B:1505–9


Bone & Joint Open
Vol. 4, Issue 1 | Pages 19 - 26
13 Jan 2023
Nishida K Nasu Y Hashizume K Okita S Nakahara R Saito T Ozaki T Inoue H

Aims

There are concerns regarding complications and longevity of total elbow arthroplasty (TEA) in young patients, and the few previous publications are mainly limited to reports on linked elbow devices. We investigated the clinical outcome of unlinked TEA for patients aged less than 50 years with rheumatoid arthritis (RA).

Methods

We retrospectively reviewed the records of 26 elbows of 21 patients with RA who were aged less than 50 years who underwent primary TEA with an unlinked elbow prosthesis. The mean patient age was 46 years (35 to 49), and the mean follow-up period was 13.6 years (6 to 27). Outcome measures included pain, range of motion, Mayo Elbow Performance Score (MEPS), radiological evaluation for radiolucent line and loosening, complications, and revision surgery with or without implant removal.


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 970 - 977
1 Sep 2024
De Rus Aznar I Ávila Lafuente JL Hachem A Díaz Heredia J Kany J Elhassan B Ruiz Ibán MÁ

Rotator cuff pathology is the main cause of shoulder pain and dysfunction in older adults. When a rotator cuff tear involves the subscapularis tendon, the symptoms are usually more severe and the prognosis after surgery must be guarded. Isolated subscapularis tears represent 18% of all rotator cuff tears and arthroscopic repair is a good alternative primary treatment. However, when the tendon is deemed irreparable, tendon transfers are the only option for younger or high-functioning patients. The aim of this review is to describe the indications, biomechanical principles, and outcomes which have been reported for tendon transfers, which are available for the treatment of irreparable subscapularis tears.

The best tendon to be transferred remains controversial. Pectoralis major transfer was described more than 30 years ago to treat patients with failed surgery for instability of the shoulder. It has subsequently been used extensively to manage irreparable subscapularis tendon tears in many clinical settings. Although pectoralis major reproduces the position and orientation of the subscapularis in the coronal plane, its position in the axial plane – anterior to the rib cage – is clearly different and does not allow it to function as an ideal transfer. Consistent relief of pain and moderate recovery of strength and function have been reported following the use of this transfer. In an attempt to improve on these results, latissimus dorsi tendon transfer was proposed as an alternative and the technique has evolved from an open to an arthroscopic procedure. Satisfactory relief of pain and improvements in functional shoulder scores have recently been reported following its use. Both pectoralis minor and upper trapezius transfers have also been used in these patients, but the outcomes that have been reported do not support their widespread use.

Cite this article: Bone Joint J 2024;106-B(9):970–977.


Bone & Joint Open
Vol. 4, Issue 2 | Pages 110 - 119
21 Feb 2023
Macken AA Prkić A van Oost I Spekenbrink-Spooren A The B Eygendaal D

Aims

The aim of this study is to report the implant survival and factors associated with revision of total elbow arthroplasty (TEA) using data from the Dutch national registry.

Methods

All TEAs recorded in the Dutch national registry between 2014 and 2020 were included. The Kaplan-Meier method was used for survival analysis, and a logistic regression model was used to assess the factors associated with revision.


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1327 - 1332
1 Nov 2024
Ameztoy Gallego J Diez Sanchez B Vaquero-Picado A Antuña S Barco R

Aims

In patients with a failed radial head arthroplasty (RHA), simple removal of the implant is an option. However, there is little information in the literature about the outcome of this procedure. The aim of this study was to review the mid-term clinical and radiological results, and the rate of complications and removal of the implant, in patients whose initial RHA was undertaken acutely for trauma involving the elbow.

Methods

A total of 11 patients in whom removal of a RHA without reimplantation was undertaken as a revision procedure were reviewed at a mean follow-up of 8.4 years (6 to 11). The range of motion (ROM) and stability of the elbow were recorded. Pain was assessed using a visual analogue scale (VAS). The functional outcome was assessed using the Mayo Elbow Performance Score (MEPS), the Oxford Elbow Score (OES), and the Disabilities of the Arm, Shoulder and Hand questionnaire (DASH). Radiological examination included the assessment of heterotopic ossification (HO), implant loosening, capitellar erosion, overlengthening, and osteoarthritis. Complications and the rate of further surgery were also recorded.


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1321 - 1326
1 Nov 2024
Sanchez-Sotelo J

Periprosthetic joint infection represents a devastating complication after total elbow arthroplasty. Several measures can be implemented before, during, and after surgery to decrease infection rates, which exceed 5%. Debridement with antibiotics and implant retention has been reported to be successful in less than one-third of acute infections, but still plays a role. For elbows with well-fixed implants, staged retention seems to be equally successful as the more commonly performed two-stage reimplantation, both with a success rate of 70% to 80%. Permanent resection or even amputation are occasionally considered. Not uncommonly, a second-stage reimplantation requires complex reconstruction of the skeleton with allografts, and the extensor mechanism may also be deficient. Further developments are needed to improve our management of infection after elbow arthroplasty.

Cite this article: Bone Joint J 2024;106-B(11):1321–1326.


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 842 - 848
1 Aug 2024
Kriechling P Whitefield R Makaram NS Brown IDM Mackenzie SP Robinson CM

Aims

Vascular compromise due to arterial injury is a rare but serious complication of a proximal humeral fracture. The aims of this study were to report its incidence in a large urban population, and to identify clinical and radiological factors which are associated with this complication. We also evaluated the results of the use of our protocol for the management of these injuries.

Methods

A total of 3,497 adult patients with a proximal humeral fracture were managed between January 2015 and December 2022 in a single tertiary trauma centre. Their mean age was 66.7 years (18 to 103) and 2,510 (72%) were female. We compared the demographic data, clinical features, and configuration of those whose fracture was complicated by vascular compromise with those of the remaining patients. The incidence of vascular compromise was calculated from national population data, and predictive factors for its occurrence were investigated using univariate analysis.


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 534 - 542
1 May 2023
Makaram NS Khan LAK Jenkins PJ Robinson CM

Aims

The outcomes following nonoperative management of minimally displaced greater tuberosity (GT) fractures, and the factors which influence patient experience, remain poorly defined. We assessed the early patient-derived outcomes following these injuries and examined the effect of a range of demographic- and injury-related variables on these outcomes.

Methods

In total, 101 patients (53 female, 48 male) with a mean age of 50.9 years (19 to 76) with minimally displaced GT fractures were recruited to a prospective observational cohort study. During the first year after injury, patients underwent experiential assessment using the Disabilities of the Arm, Shoulder and Hand (DASH) score and assessment of associated injuries using MRI performed within two weeks of injury. The primary outcome was the one-year DASH score. Multivariate analysis was used to assess the effect of patient demographic factors, complications, and associated injuries, on outcome.


Bone & Joint Open
Vol. 4, Issue 3 | Pages 205 - 209
16 Mar 2023
Jump CM Mati W Maley A Taylor R Gratrix K Blundell C Lane S Solanki N Khan M Choudhry M Shetty V Malik RA Charalambous CP

Aims

Frozen shoulder is a common, painful condition that results in impairment of function. Corticosteroid injections are commonly used for frozen shoulder and can be given as glenohumeral joint (GHJ) injection or suprascapular nerve block (SSNB). Both injection types have been shown to significantly improve shoulder pain and range of motion. It is not currently known which is superior in terms of relieving patients’ symptoms. This is the protocol for a randomized clinical trial to investigate the clinical effectiveness of corticosteroid injection given as either a GHJ injection or SSNB.

Methods

The Therapeutic Injections For Frozen Shoulder (TIFFS) study is a single centre, parallel, two-arm, randomized clinical trial. Participants will be allocated on a 1:1 basis to either a GHJ corticosteroid injection or SSNB. Participants in both trial arms will then receive physiotherapy as normal for frozen shoulder. The primary analysis will compare the Oxford Shoulder Score (OSS) at three months after injection. Secondary outcomes include OSS at six and 12 months, range of shoulder movement at three months, and Numeric Pain Rating Scale, abbreviated Disabilities of Arm, Shoulder and Hand score, and EuroQol five-level five-dimension health index at three months, six months, and one year after injection. A minimum of 40 patients will be recruited to obtain 80% power to detect a minimally important difference of ten points on the OSS between the groups at three months after injection. The study is registered under ClinicalTrials.gov with the identifier NCT04965376.


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 182 - 188
1 Feb 2024
Gallego JA Rotman D Watts AC

Aims

Acute and chronic injuries of the interosseus membrane can result in longitudinal instability of the forearm. Reconstruction of the central band of the interosseus membrane can help to restore biomechanical stability. Different methods have been used to reconstruct the central band, including tendon grafts, bone-ligament-bone grafts, and synthetic grafts. This Idea, Development, Exploration, Assessment, and Long-term (IDEAL) phase 1 study aims to review the clinical results of reconstruction using a synthetic braided cross-linked graft secured at either end with an Endobutton to restore the force balance between the bones of the forearm.

Methods

An independent retrospective review was conducted of a consecutive series of 21 patients with longitudinal instability injuries treated with anatomical central band reconstruction between February 2011 and July 2019. Patients with less than 12 months’ follow-up or who were treated acutely were excluded, leaving 18 patients in total. Preoperative clinical and radiological assessments were compared with prospectively gathered data using range of motion and the abbreviated version of the Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH) functional outcome score.


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1293 - 1300
1 Nov 2024
O’Malley O Craven J Davies A Sabharwal S Reilly P

Aims

Reverse shoulder arthroplasty (RSA) has become the most common type of shoulder arthroplasty used in the UK, and a better understanding of the outcomes after revision of a failed RSA is needed. The aim of this study was to review the current evidence systematically to determine patient-reported outcome measures and the rates of re-revision and complications for patients undergoing revision of a RSA.

Methods

MEDLINE, Embase, CENTRAL, and the Cochrane Database of Systematic Reviews were searched. Studies involving adult patients who underwent revision of a primary RSA for any indication were included. Those who underwent a RSA for failure of a total shoulder arthroplasty or hemiarthroplasty were excluded. Pre- and postoperative shoulder scores were evaluated in a random effects meta-analysis to determine the mean difference. The rates of re-revision and complications were also calculated.


The Bone & Joint Journal
Vol. 105-B, Issue 9 | Pages 1000 - 1006
1 Sep 2023
Macken AA Haagmans-Suman A Spekenbrink-Spooren A van Noort A van den Bekerom MPJ Eygendaal D Buijze GA

Aims

The current evidence comparing the two most common approaches for reverse total shoulder arthroplasty (rTSA), the deltopectoral and anterosuperior approach, is limited. This study aims to compare the rate of loosening, instability, and implant survival between the two approaches for rTSA using data from the Dutch National Arthroplasty Registry with a minimum follow-up of five years.

Methods

All patients in the registry who underwent a primary rTSA between January 2014 and December 2016 using an anterosuperior or deltopectoral approach were included, with a minimum follow-up of five years. Cox and logistic regression models were used to assess the association between the approach and the implant survival, instability, and glenoid loosening, independent of confounders.


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1111 - 1117
1 Oct 2024
Makaram NS Becher H Oag E Heinz NR McCann CJ Mackenzie SP Robinson CM

Aims

The risk factors for recurrent instability (RI) following a primary traumatic anterior shoulder dislocation (PTASD) remain unclear. In this study, we aimed to determine the rate of RI in a large cohort of patients managed nonoperatively after PTASD and to develop a clinical prediction model.

Methods

A total of 1,293 patients with PTASD managed nonoperatively were identified from a trauma database (mean age 23.3 years (15 to 35); 14.3% female). We assessed the prevalence of RI, and used multivariate regression modelling to evaluate which demographic- and injury-related factors were independently predictive for its occurrence.


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1303 - 1313
1 Dec 2023
Trammell AP Hao KA Hones KM Wright JO Wright TW Vasilopoulos T Schoch BS King JJ

Aims

Both anatomical and reverse total shoulder arthroplasty (aTSA and rTSA) provide functional improvements. A reported benefit of aTSA is better range of motion (ROM). However, it is not clear which procedure provides better outcomes in patients with limited foward elevation (FE). The aim of this study was to compare the outcome of aTSA and rTSA in patients with glenohumeral osteoarthritis (OA), an intact rotator cuff, and limited FE.

Methods

This was a retrospective review of a single institution’s prospectively collected shoulder arthroplasty database for TSAs undertaken between 2007 and 2020. A total of 344 aTSAs and 163 rTSAs, which were performed in patients with OA and an intact rotator cuff with a minimum follow-up of two years, were included. Using the definition of preoperative stiffness as passive FE ≤ 105°, three cohorts were matched 1:1 by age, sex, and follow-up: stiff aTSAs (85) to non-stiff aTSAs (85); stiff rTSAs (74) to non-stiff rTSAs (74); and stiff rTSAs (64) to stiff aTSAs (64). We the compared ROMs, outcome scores, and complication and revision rates.


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 912 - 919
1 Aug 2023
Cunningham LJ Walton M Bale S Trail IA

Aims

Reverse total shoulder arthroplasty (rTSA) can be used in complex cases when the glenoid requires reconstruction. In this study, a baseplate with composite bone autograft and a central trabecular titanium peg was implanted, and its migration was assessed for two years postoperatively using radiostereometric analysis (RSA).

Methods

A total of 14 patients who underwent a rTSA with an autograft consented to participate. Of these, 11 had a primary rTSA using humeral head autograft and three had a revision rTSA with autograft harvested from the iliac crest. The mean age of the patients was 66 years (39 to 81). Tantalum beads were implanted in the scapula around the glenoid. RSA imaging (stereographic radiographs) was undertaken immediately postoperatively and at three, six, 12, and 24 months. Analysis was completed using model-based RSA software. Outcomes were collected preoperatively and at two years postoperatively, including the Oxford Shoulder Score, the American Shoulder and Elbow Score, and a visual analogue score for pain. A Constant score was also obtained for the assessment of strength and range of motion.


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1263 - 1272
1 Nov 2024
Amador IE Hao KA Buchanan TR Damrow DS Hones KM Simcox T Schoch BS Farmer KW Wright TW LaMonica TJ King JJ Wright JO

Aims

We sought to compare functional outcomes and survival between non-smokers, former smokers, and current smokers who underwent anatomical total shoulder arthroplasty (aTSA) in a large cohort of patients.

Methods

A retrospective review of a prospectively collected shoulder arthroplasty database was performed between August 1991 and September 2020 to identify patients who underwent primary aTSA. Patients were excluded for preoperative diagnoses of fracture, infection, or oncological disease. Three cohorts were created based on smoking status: non-smokers, former smokers, and current smokers. Outcome scores (American Shoulder and Elbow Surgeons (ASES), Constant-Murley score, Shoulder Pain and Disability Index (SPADI), Simple Shoulder Test (SST), University of California, Los Angeles activity scale (UCLA)), range of motion (external rotation (ER), forward elevation (FE), internal rotation, abduction), and shoulder strength (ER, FE) evaluated at two- to four-year follow-up were compared between cohorts. Evaluation of revision-free survival was performed using the Kaplan-Meier method to final follow-up.


The Bone & Joint Journal
Vol. 105-B, Issue 4 | Pages 389 - 399
15 Mar 2023
Makaram NS Nicholson JA Yapp LZ Gillespie M Shah CP Robinson CM

Aims

The open Latarjet procedure is a widely used treatment for recurrent anterior instability of the shoulder. Although satisfactory outcomes are reported, factors which influence a patient’s experience are poorly quantified. The aim of this study was to evaluate the effect of a range of demographic factors and measures of the severity of instability on patient-reported outcome measures in patients who underwent an open Latarjet procedure at a minimum follow-up of two years.

Methods

A total of 350 patients with anterior instability of the shoulder who underwent an open Latarjet procedure between 2005 and 2018 were reviewed prospectively, with the collection of demographic and psychosocial data, preoperative CT, and complications during follow-up of two years. The primary outcome measure was the Western Ontario Shoulder Instability Index (WOSI), assessed preoperatively, at two years postoperatively, and at mid-term follow-up at a mean of 50.6 months (SD 24.8) postoperatively. The secondary outcome measure was the abbreviated version of the Disabilities of the Arm, Shoulder and Hand (QuickDASH) score. The influence of the demographic details of the patients, measurements of the severity of instability, and the complications of surgery were assessed in a multivariate analysis.


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1148 - 1155
1 Oct 2022
Watts AC Hamoodi Z McDaid C Hewitt C

Aims

Arthroplasties of the elbow, including total elbow arthroplasty, radial head arthroplasty, distal humeral hemiarthroplasty, and radiocapitellar arthroplasty, are rarely undertaken. This scoping review aims to outline the current research in this area to inform the development of future research.

Methods

A scoping review was undertaken adhering to the Joanna Briggs Institute guidelines using Medline, Embase, CENTRAL, and trial registries, limited to studies published between 1 January 1990 and 7 February 2021. Endnote software was used for screening and selection, and included randomized trials, non-randomized controlled trials, prospective and retrospective cohort studies, case-control studies, analytical cross-sectional studies, and case series of ten or more patients reporting the clinical outcomes of elbow arthroplasty. The results are presented as the number of types of studies, sample size, length of follow-up, clinical outcome domains and instruments used, sources of funding, and a narrative review.


The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1377 - 1384
1 Oct 2015
Nestorson J Ekholm C Etzner M Adolfsson L

We report our experience of performing an elbow hemiarthroplasty in the treatment of comminuted distal humeral fractures in the elderly patients. A cohort of 42 patients (three men and 39 women, mean age 72; 56 to 84) were reviewed at a mean of 34.3 months (24 to 61) after surgery. Functional outcome was measured with the Mayo Elbow Performance Score (MEPS) and range of movement. The disabilities of the arm, shoulder and hand questionnaire (DASH) was used as a patient rated evaluation. Complications and ulnar nerve function were recorded. Plain radiographs were obtained to assess prosthetic loosening, olecranon wear and heterotopic bone formation. The mean extension deficit was 23.5° (0° to 60°) and mean flexion was 126.8° (90° to 145°) giving a mean arc of 105.5° (60° to 145°). The mean MEPS was 90 (50 to 100) and a mean DASH score of 20 (0 to 63). Four patients had additional surgery for limited range of movement and one for partial instability. One elbow was revised due to loosening, two patients had sensory ulnar nerve symptoms, and radiographic signs of mild olecranon wear was noted in five patients. Elbow hemiarthroplasty for comminuted intra-articular distal humeral fractures produces reliable medium-term results with functional outcome and complication rates, comparable with open reduction and internal fixation and total elbow arthroplasty. Cite this article: Bone Joint J 2015;97-B:1377–84


The Bone & Joint Journal
Vol. 104-B, Issue 3 | Pages 401 - 407
1 Mar 2022
Kriechling P Zaleski M Loucas R Loucas M Fleischmann M Wieser K

Aims

The aim of this study was to report the incidence of implant-related complications, further operations, and their influence on the outcome in a series of patients who underwent primary reverse total shoulder arthroplasty (RTSA).

Methods

The prospectively collected clinical and radiological data of 797 patients who underwent 854 primary RTSAs between January 2005 and August 2018 were analyzed. The hypothesis was that the presence of complications would adversely affect the outcome. Further procedures were defined as all necessary operations, including reoperations without change of components, and partial or total revisions. The clinical outcome was evaluated using the absolute and relative Constant Scores (aCS, rCS), the Subjective Shoulder Value (SSV) scores, range of motion, and pain.


The Bone & Joint Journal
Vol. 104-B, Issue 4 | Pages 486 - 494
4 Apr 2022
Liu W Sun Z Xiong H Liu J Lu J Cai B Wang W Fan C

Aims

The aim of this study was to develop and internally validate a prognostic nomogram to predict the probability of gaining a functional range of motion (ROM ≥ 120°) after open arthrolysis of the elbow in patients with post-traumatic stiffness of the elbow.

Methods

We developed the Shanghai Prediction Model for Elbow Stiffness Surgical Outcome (SPESSO) based on a dataset of 551 patients who underwent open arthrolysis of the elbow in four institutions. Demographic and clinical characteristics were collected from medical records. The least absolute shrinkage and selection operator regression model was used to optimize the selection of relevant features. Multivariable logistic regression analysis was used to build the SPESSO. Its prediction performance was evaluated using the concordance index (C-index) and a calibration graph. Internal validation was conducted using bootstrapping validation.


The Bone & Joint Journal
Vol. 98-B, Issue 11 | Pages 1521 - 1525
1 Nov 2016
Su Y Nan G

Aims. Cubitus varus is the most common late complication of a supracondylar fracture of the humerus in children. Correction can be performed using one of a number of techniques of osteotomy but each has disadvantages. We describe a new technique for correcting post-traumatic cubitus varus using a lateral closing wedge isosceles triangular osteotomy. Patients and Methods. A lateral closing wedge isosceles triangular osteotomy was performed in 25 patients (15 male and ten female with a mean age of 9.5 years (6 to 12)) between May 2010 and April 2013. All patients had cubitus varus secondary to malunion of a supracondylar fracture, with good function of the elbow and a full range of movement. The osteotomy lines were marked on the bone with an isosceles triangular template made before surgery, after which the osteotomy was performed leaving the medial cortex intact. Fixation was performed using two lateral 2 mm Kirschner (K)-wires and patients were immobilised in an above-elbow plaster. By six to eight weeks callus was present and the wires and cast were removed. Patients were reviewed at four and six weeks, three, six and 12 months and then every two years until skeletal maturity. Clinical and radiographic outcomes were categorised as excellent, good or poor. Results. A total of 23 patients had an excellent and two had a good outcome at a mean final follow-up of 3.4 years (two to four). The mean post-operative carrying angle in the corrected elbow was 11.7° (7° to 18°). One patient fell, displacing the osteotomy, and needed revision of the fixation. No patient had a nerve injury. Conclusion. A lateral isosceles triangular osteotomy and with K-wire fixation is a practical, effective, reliable, safe and simple method of correcting post-traumatic cubitus varus in children. It has inherent stability and excellent cosmesis without prominence of the lateral condyle. . Cite this article: Bone Joint J 2016;98-B:1521–5


The Bone & Joint Journal
Vol. 98-B, Issue 1 | Pages 65 - 74
1 Jan 2016
Phadnis J Huang T Watts A Krishnan J Bain GI

Aims. To date, there is insufficient evidence available to compare the outcome of cemented and uncemented fixation of the humeral stem in reverse shoulder arthroplasty (RSA). . Methods. A systemic review comprising 41 clinical studies was performed to compare the functional outcome and rate of complications of cemented and uncemented stems in RSA. These included 1455 cemented and 329 uncemented shoulders. The clinical characteristics of the two groups were similar. Variables were compared using pooled frequency-weighted means and relative risk ratios (RR). Results. Uncemented stems had a significantly higher incidence of early humeral stem migration (p < 0.001, RR 18.1, 95% confidence interval (CI) 5.0 to 65.2) and non-progressive radiolucent lines (p < 0.001, RR 2.4, 95% CI 1.7 to 3.4), but a significantly lower incidence of post-operative fractures of the acromion compared with cemented stems (p = 0.004, RR 14.3, 95% CI 0.9 to 232.8). There was no difference in the risk of stem loosening or revision between the groups. The cemented stems had a greater relative risk of infection (RR 3.3, 95% CI 0.8 to 13.7), nerve injury (RR 5.7, 95% CI 0.7 to 41.5) and thromboembolism (RR 3.9, 95% CI 0.2 to 66.6). The functional outcome and range of movement were equivalent in the two groups. . Discussion. RSA performed with an uncemented stem gives them equivalent functional outcome and a better complication profile than with a cemented stem. The natural history and clinical relevance of early stem migration and radiolucent lines found with uncemented stems requires further long-term study. Take home message: This study demonstrates that uncemented stems have at least equivalent clinical and radiographic outcomes compared with cemented stems when used for reverse total shoulder arthroplasty. . Cite this article: Bone Joint J 2016;98-B:65–74


The Bone & Joint Journal
Vol. 103-B, Issue 10 | Pages 1619 - 1626
1 Oct 2021
Bi M Zhou K Gan K Ding W Zhang T Ding S Li J

Aims

The aim of this study is to provide a detailed description of cases combining bridging patch repair with artificial ligament “internal brace” reinforcement to treat irreparable massive rotator cuff tears, and report the preliminary results.

Methods

This is a retrospective review of patients with irreparable massive rotator cuff tears undergoing fascia lata autograft bridging repair with artificial ligament “internal brace” reinforcement technique between January 2017 and May 2018. Inclusion criteria were: patients treated arthroscopically for an incompletely reparable massive rotator cuff tear (dimension > 5 cm or two tendons fully torn), stage 0 to 4 supraspinatus fatty degeneration on MRI according to the Goutallier grading system, and an intact or reparable infraspinatus and/or subscapularis tendon of radiological classification Hamada 0 to 4. The surgical technique comprised two components: first, superior capsular reconstruction using an artificial ligament as an “internal brace” protective device for a fascia lata patch. The second was fascia lata autograft bridging repair for the torn supraspinatus. In all, 26 patients with a mean age 63.4 years (SD 6.2) were included.


The Bone & Joint Journal
Vol. 96-B, Issue 6 | Pages 795 - 799
1 Jun 2014
Gamo K Kuriyama K Higuchi H Uesugi A Nakase T Hamada M Kawai H

We examined the outcomes and levels of patient satisfaction in 202 consecutive cases of ultrasound-guided supraclavicular brachial plexus block (SBPB) in upper limb surgery performed between September 2007 and March 2010. All blocks were performed by orthopaedic surgeons using ultrasound visualisation with a high-frequency linear probe. The probe was placed in the coronal–oblique plane in the supraclavicular fossa, and the puncture was ‘in-plane’ from lateral to medial. Most of the blocks were performed with 0.75% ropivacaine/1% lidocaine (1:1), with or without adrenaline in 1:200 000 dilution. In 201 patients (99.5%) the brachial plexus block permitted surgery without conversion to general anaesthesia. The mean procedure time for block was 3.9 min (2 to 12), the mean waiting time for surgery was 34.1 min (10 to 64), the mean surgical time was 75.2 min (6 to 232), and the mean duration of post-anaesthetic analgesia was 437 min (171 to 992). A total of 20 patients (10%) developed a transient Horner’s syndrome. No nerve injury, pneumothorax, arterial puncture or systemic anaesthetic toxicity were recorded. Most patients (96.7%) were satisfied with ultrasound-guided SBPB. This study demonstrates the efficacy and safety of ultrasound-guided SBPB for orthopaedic surgery on the upper limb. Cite this article: Bone Joint J 2014;96-B:795–9


Bone & Joint Open
Vol. 2, Issue 1 | Pages 58 - 65
22 Jan 2021
Karssiens TJ Gill JR Sunil Kumar KH Sjolin SU

Aims

The Mathys Affinis Short is the most frequently used stemless total shoulder prosthesis in the UK. The purpose of this prospective cohort study is to report the survivorship, clinical, and radiological outcomes of the first independent series of the Affinis Short prosthesis.

Methods

From January 2011 to January 2019, a total of 141 Affinis Short prostheses were implanted in 127 patients by a single surgeon. Mean age at time of surgery was 68 (44 to 89). Minimum one year and maximum eight year follow-up (mean 3.7 years) was analyzed using the Oxford Shoulder Score (OSS) at latest follow-up. Kaplan-Meier survivorship analysis was performed with implant revision as the endpoint. Most recently performed radiographs were reviewed for component radiolucent lines (RLLs) and proximal humeral migration.


Bone & Joint Open
Vol. 1, Issue 9 | Pages 576 - 584
18 Sep 2020
Sun Z Liu W Li J Fan C

Post-traumatic elbow stiffness is a disabling condition that remains challenging for upper limb surgeons. Open elbow arthrolysis is commonly used for the treatment of stiff elbow when conservative therapy has failed. Multiple questions commonly arise from surgeons who deal with this disease. These include whether the patient has post-traumatic stiff elbow, how to evaluate the problem, when surgery is appropriate, how to perform an excellent arthrolysis, what the optimal postoperative rehabilitation is, and how to prevent or reduce the incidence of complications. Following these questions, this review provides an update and overview of post-traumatic elbow stiffness with respect to the diagnosis, preoperative evaluation, arthrolysis strategies, postoperative rehabilitation, and prevention of complications, aiming to provide a complete diagnosis and treatment path.

Cite this article: Bone Joint Open 2020;1-9:576–584.


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 366 - 372
1 Feb 2021
Sun Z Li J Luo G Wang F Hu Y Fan C

Aims

This study aimed to determine the minimal detectable change (MDC), minimal clinically important difference (MCID), and substantial clinical benefit (SCB) under distribution- and anchor-based methods for the Mayo Elbow Performance Index (MEPI) and range of movement (ROM) after open elbow arthrolysis (OEA). We also assessed the proportion of patients who achieved MCID and SCB; and identified the factors associated with achieving MCID.

Methods

A cohort of 265 patients treated by OEA were included. The MEPI and ROM were evaluated at baseline and at two-year follow-up. Distribution-based MDC was calculated with confidence intervals (CIs) reflecting 80% (MDC 80), 90% (MDC 90), and 95% (MDC 95) certainty, and MCID with changes from baseline to follow-up. Anchor-based MCID (anchored to somewhat satisfied) and SCB (very satisfied) were calculated using a five-level Likert satisfaction scale. Multivariate logistic regression of factors affecting MCID achievement was performed.


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 718 - 724
1 Apr 2021
Cavalier M Johnston TR Tran L Gauci M Boileau P

Aims

The aim of this study was to identify risk factors for recurrent instability of the shoulder and assess the ability to return to sport in patients with engaging Hill-Sachs lesions treated with arthroscopic Bankart repair and Hill-Sachs remplissage (ABR-HSR).

Methods

This retrospective study included 133 consecutive patients with a mean age of 30 years (14 to 69) who underwent ABR-HSR; 103 (77%) practiced sports before the instability of the shoulder. All had large/deep, engaging Hill-Sachs lesions (Calandra III). Patients were divided into two groups: A (n = 102) with minimal or no (< 10%) glenoid bone loss, and B (n = 31) with subcritical (10% to 20%) glenoid loss. A total of 19 patients (14%) had undergone a previous stabilization, which failed. The primary endpoint was recurrent instability, with a secondary outcome of the ability to return to sport.


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1239 - 1243
1 Sep 2014
Zafra M Uceda P Flores M Carpintero P

Patients with pain and loss of shoulder function due to nonunion of a fracture of the proximal third of the humerus may benefit from reverse total shoulder replacement. This paper reports a prospective, multicentre study, involving three hospitals and three surgeons, of 35 patients (28 women, seven men) with a mean age of 69 years (46 to 83) who underwent a reverse total shoulder replacement for the treatment of nonunion of a fracture of the proximal humerus. Using Checchia’s classification, nine nonunions were type I, eight as type II, 12 as type III and six as type IV. The mean follow-up was 51 months (24 to 99). Post-operatively, the patients had a significant decrease in pain (p < 0.001), and a significant improvement in flexion, abduction, external rotation and Constant score (p < 0.001), but not in internal rotation. A total of nine complications were recorded in seven patients: six dislocations, one glenoid loosening in a patient who had previously suffered dislocation, one transitory paresis of the axillary nerve and one infection. Reverse total shoulder replacement may lead to a significant reduction in pain, improvement in function and a high degree of satisfaction. However, the rate of complications, particularly dislocation, was high. Cite this article: Bone Joint J 2014;96-B:1239–43


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 360 - 365
1 Feb 2021
Mahendraraj KA Shields MV Grubhofer F Golenbock SW Jawa A

Aims

Existing literature indicates that inferiorly inclined glenoid baseplates following reverse total shoulder arthroplasty (RSA) produce better outcomes compared to superiorly inclined baseplates. We aim to compare clinical outcomes for RSAs with superiorly and neutrally/inferiorly inclined lateralized glenospheres.

Methods

We retrospectively reviewed 154 consecutive patients undergoing RSA between July 2015 and July 2017 by one single-fellowship trained surgeon (AJ). Two raters (KAM and MVS) independently measured glenoid inclination in preoperative and minimum two year follow-up radiographs (anteroposterior/Grashey) using the RSA angle. Inclination was then compared to patient-reported outcomes, range of motion (ROM), and independently assessed degree of scapular notching and staging of heterotopic ossification at two year follow-up.


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1280 - 1284
1 Oct 2019
Kang JR Logli AL Tagliero AJ Sperling JW

Aims

A number of methods have been described to remove a well-fixed humeral implant as part of revision shoulder arthroplasty. These include the use of cortical windows and humeral osteotomies. The router bit extraction technique uses a high-speed router bit to disrupt the bone-implant interface. The implant is then struck in a retrograde fashion with a square-tip impactor and mallet. The purpose of this study was to determine the characteristics and frequency of the different techniques needed for the removal of a well-fixed humeral stem in revision shoulder arthroplasty.

Patients and Methods

Between 2010 and 2018, 288 revision shoulder arthroplasty procedures requiring removal of a well-fixed humeral component were carried out at a tertiary referral centre by a single surgeon. The patient demographics, indications for surgery, and method of extraction were collected.


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1272 - 1279
1 Oct 2019
Nowak LL Hall J McKee MD Schemitsch EH

Aims

To compare complication-related reoperation rates following primary arthroplasty for proximal humerus fractures (PHFs) versus secondary arthroplasty for failed open reduction and internal fixation (ORIF).

Patients and Methods

We identified patients aged 50 years and over, who sustained a PHF between 2004 and 2015, from linkable datasets. We used intervention codes to identify patients treated with initial ORIF or arthroplasty, and those treated with ORIF who returned for revision arthroplasty within two years. We used multilevel logistic regression to compare reoperations between groups.


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1107 - 1114
1 Sep 2019
Uy M Wang J Horner NS Bedi A Leroux T Alolabi B Khan M

Aims

The aim of this study was to evaluate the differences in revision and complication rates, functional outcomes, and radiological outcomes between cemented and press-fit humeral stems in primary anatomical total shoulder arthroplasty (TSA).

Materials and Methods

A comprehensive systematic review and meta-analysis was conducted searching for studies that included patients who underwent primary anatomical TSA for primary osteoarthritis or rheumatoid arthritis.


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1520 - 1525
1 Dec 2019
Clark NJ Samuelsen BT Alentorn-Geli E Assenmacher AT Cofield RH Sperling JW Sánchez-Sotelo J

Aims

Reverse shoulder arthroplasty (RSA) reliably improves shoulder pain and function for a variety of indications. However, the safety and efficacy of RSA in elderly patients is largely unknown. The purpose of this study was to report the mortality, morbidity, complications, reoperations, and outcomes of primary RSA in patients aged > 80 years.

Patients and Methods

Between 2004 and 2013, 242 consecutive primary RSAs were performed in patients aged > 80 years (mean 83.3 years (sd 3.1)). Of these, 53 were lost to follow-up before two years and ten had died within two years of surgery, leaving 179 for analysis of survivorship, pain, motion, and strength at a minimum of two years or until revision surgery. All 242 patients were considered for the analysis of 90-day, one-year, and overall mortality, medical complications (90-day and overall), surgical complications, and reoperations. The indications for surgery included rotator cuff arthropathy, osteoarthritis, fracture, the sequela of trauma, avascular necrosis, and rheumatoid arthritis. A retrospective review of the medical records was performed to collect all variables. Survivorship free of revision surgery was calculated at two and five years.


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1066 - 1073
1 Aug 2018
Nishida K Hashizume K Nasu Y Ozawa M Fujiwara K Inoue H Ozaki T

Aims

The aim of this study was to report the mid-term clinical outcome of cemented unlinked J-alumina ceramic elbow (JACE) arthroplasties when used in patients with rheumatoid arthritis (RA).

Patients and Methods

We retrospectively reviewed 87 elbows, in 75 patients with RA, which was replaced using a cemented JACE total elbow arthroplasty (TEA) between August 2003 and December 2012, with a follow-up of 96%. There were 72 women and three men, with a mean age of 62 years (35 to 79). The mean follow-up was nine years (2 to 14). The clinical condition of each elbow before and after surgery was assessed using the Mayo Elbow Performance Index (MEPI, 0 to 100 points). Radiographic loosening was defined as a progressive radiolucent line of >1 mm that was completely circumferential around the prosthesis.


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1609 - 1617
1 Dec 2018
Malhas AM Granville-Chapman J Robinson PM Brookes-Fazakerley S Walton M Monga P Bale S Trail I

Aims

We present our experience of using a metal-backed prosthesis and autologous bone graft to treat gross glenoid bone deficiency.

Patients and Methods

A prospective cohort study of the first 45 shoulder arthroplasties using the SMR Axioma Trabecular Titanium (TT) metal-backed glenoid with autologous bone graft. Between May 2013 and December 2014, 45 shoulder arthroplasties were carried out in 44 patients with a mean age of 64 years (35 to 89). The indications were 23 complex primary arthroplasties, 12 to revise a hemiarthroplasty or resurfacing, five for aseptic loosening of the glenoid, and five for infection.


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1499 - 1505
1 Nov 2018
Mazhar FN Ebrahimi H Jafari D Mirzaei A

Aims

The crucial role of the radial head in the stability of the elbow in terrible triad injury is acknowledged. This retrospective study aims to compare the results of resection of a severely comminuted radial head with or without prosthetic arthroplasty as part of the reconstruction for this injury.

Patients and Methods

The outcome of radial head resection was compared with prosthetic arthroplasty in 29 and 15 patients with terrible triad injuries, respectively. There were ten female patients (34.5%) in the resection group and six female patients (40%) in the prosthesis group. The mean age was 40.7 years (sd 13.6) in the resection group and 36 years (sd 9.4) in the prosthesis group. The mean follow-up of the patients was 24.4 months (sd 12) in the resection group and 45.8 months (sd 6.8) in the prosthesis group. Outcome measures included visual analogue scale (VAS) for pain, Mayo Elbow Performance Score (MEPS), Disabilities of Arm, Shoulder and Hand (DASH) Score, and range of movement. Postoperative radiological complications were also recorded.


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 603 - 609
1 May 2019
Aagaard KE Lunsjö K Frobell R

Aims

Failure of healing is a well-known problem after repair of the rotator cuff. This study aimed to investigate if early repair of trauma-related full-thickness rotator cuff tears (FTRCTs) could prevent this failure.

Patients and Methods

In this prospective trial, 62 consecutive patients (14 women (23%), 48 men (77%); median age 61 years (interquartile range (IQR) 54 to 65)) with trauma-related FTRCT underwent arthroscopic single-row repair within six weeks of trauma. Tendon integrity was assessed one year after surgery using the Sugaya score on MR images. Patients were followed up with Western Ontario Rotator Cuff (WORC) index, EuroQol visual analogue scale (EQ VAS), and the Constant–Murley score (CS) two years after repair.


The Bone & Joint Journal
Vol. 100-B, Issue 3 | Pages 346 - 351
1 Mar 2018
Goodall R Claireaux H Hill J Wilson E Monsell F BOAST 11 Collaborative Tarassoli P

Aims

Supracondylar fractures are the most frequently occurring paediatric fractures about the elbow and may be associated with a neurovascular injury. The British Orthopaedic Association Standards for Trauma 11 (BOAST 11) guidelines describe best practice for supracondylar fracture management. This study aimed to assess whether emergency departments in the United Kingdom adhere to BOAST 11 standard 1: a documented assessment, performed on presentation, must include the status of the radial pulse, digital capillary refill time, and the individual function of the radial, median (including the anterior interosseous), and ulnar nerves.

Materials and Methods

Stage 1: We conducted a multicentre, retrospective audit of adherence to BOAST 11 standard 1. Data were collected from eight hospitals in the United Kingdom. A total of 433 children with Gartland type 2 or 3 supracondylar fractures were eligible for inclusion. A centrally created data collection sheet was used to guide objective analysis of whether BOAST 11 standard 1 was adhered to. Stage 2: We created a quality improvement proforma for use in emergency departments. This was piloted in one of the hospitals used in the primary audit and was re-audited using equivalent methodology. In all, 102 patients presenting between January 2016 and July 2017 were eligible for inclusion in the re-audit.


The Bone & Joint Journal
Vol. 101-B, Issue 2 | Pages 147 - 153
1 Feb 2019
Mai DH Oh C Doany ME Rokito AS Kwon YW Zuckerman JD Virk MS

Aims

The aim of this study was to investigate the effects of preoperative bisphosphonate treatment on the intra- and postoperative outcomes of arthroplasty of the shoulder. The hypothesis was that previous bisphosphonate treatment would adversely affect both intra- and postoperative outcomes.

Patients and Methods

A retrospective cohort study was conducted involving patients undergoing arthroplasty of the shoulder, at a single institution. Two patients with no previous bisphosphonate treatment were matched to each patient who had received this treatment preoperatively by gender, age, race, ethnicity, body mass index (BMI), and type of arthroplasty. Previous bisphosphonate treatment was defined as treatment occurring during the three-year period before the arthroplasty. The primary outcome measure was the incidence of intraoperative complications and those occurring at one and two years postoperatively. A total of 87 patients were included: 29 in the bisphosphonates-exposed (BP+) group and 58 in the non-exposed (BP-) group. In the BP+ group, there were 26 female and three male patients, with a mean age of 71.4 years (51 to 87). In the BP- group, there were 52 female and six male patients, with a mean age of 72.1 years (53 to 88).


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 480 - 484
1 Apr 2018
Kadum B Inngul C Ihrman R Sjödén GO Sayed-Noor AS

Aims

The aims of this study were to investigate any possible relationship between a preoperative sensitivity to pain and the degree of pain at rest and on exertion with postoperative function in patients who underwent stemless total shoulder arthroplasty (TSA).

Patients and Methods

In this prospective study, we included 63 patients who underwent stemless TSA and were available for evaluation one year postoperatively. There were 31 women and 32 men; their mean age was 71 years (53 to 89). The pain threshold, which was measured using a Pain Matcher (PM) unit, the degree of pain (visual analogue scale at rest and on exertion, and function using the short version of the Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH), were recorded preoperatively, as well as three and 12 months postoperatively.


The Bone & Joint Journal
Vol. 100-B, Issue 2 | Pages 212 - 218
1 Feb 2018
Jungbluth P Tanner S Schneppendahl J Grassmann J Wild M Hakimi M Windolf J Laun R

Aims

The aim of this retrospective multicentre study was to evaluate mid-term results of the operative treatment of Monteggia-like lesions and to determine the prognostic factors that influence the clinical and radiological outcome.

Patients and Methods

A total of 46 patients (27 women and 19 men), with a mean age of 57.7 years (18 to 84) who had sustained a Monteggia-like lesion were followed up clinically and radiologically after surgical treatment. The Mayo Modified Wrist Score (MMWS), Mayo Elbow Performance Score (MEPS), Broberg and Morrey Score, and Disabilities of the Arm, Shoulder and Hand (DASH) score were used for evaluation at a mean of 65 months (27 to 111) postoperatively. All ulnar fractures were stabilized using a proximally contoured or precontoured locking compression plate. Mason type I fractures of the radial head were treated conservatively, type II fractures were treated with reconstruction, and type III fractures with arthroplasty. All Morrey type II and III fractures of the coronoid process was stabilized using lag screws.


The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 610 - 616
1 May 2018
Giannicola G Bullitta G Rotini R Murena L Blonna D Iapicca M Restuccia G Merolla G Fontana M Greco A Scacchi M Cinotti G

Aims

The aim of the study was to analyze the results of primary tendon reinsertion in acute and chronic distal triceps tendon ruptures (DTTRs) in the general population.

Patients and Methods

A total of 28 patients were operated on for primary DTTR reinsertions, including 21 male patients and seven female patients with a mean age of 45 years (14 to 76). Of these patients, 23 sustained an acute DTTR and five had a chronic injury. One patient had a non-simultaneous bilateral DTTR. Seven patients had DTTR-associated ipsilateral fracture or dislocation. Comorbidities were present in four patients. Surgical treatment included transosseous and suture-anchors reinsertion in 22 and seven DTTRs, respectively. The clinical evaluation was performed using Mayo Elbow Performance Score (MEPS), the modified American Shoulder and Elbow Surgeons Score (m-ASES), the Quick Disabilities of the Arm, Shoulder and Hand score (QuickDASH), and the Medical Research Council (MRC) Scale.


The Bone & Joint Journal
Vol. 100-B, Issue 3 | Pages 309 - 317
1 Mar 2018
Kolk A Henseler JF Overes FJ Nagels J Nelissen RGHH

Aims

Since long-term outcome of teres major tendon transfer surgery for irreparable posterosuperior rotator cuff (RC) tears is largely unknown, the primary aim of this study was to evaluate the long-term outcome of the teres major transfer. We also aimed to report on the results of a cohort of patients with a similar indication for surgery that underwent a latissimus dorsi tendon transfer.

Patients and Methods

In this prospective cohort study, we reported on the long-term results of 20 consecutive patients with a teres major tendon transfer for irreparable massive posterosuperior RC tears. Additionally, we reported on the results of the latissimus dorsi tendon transfer (n = 19). The mean age was 60 years (47 to 77). Outcomes included the Constant score (CS), and pain at rest and during movement using the Visual Analogue Scale (VAS).