21 Feb 2023
Macken AA Prkić A van Oost I Spekenbrink-Spooren A The B Eygendaal D

Aims. The aim of this study is to report the implant survival and factors associated with revision of total elbow arthroplasty (TEA) using data from the Dutch national registry. Methods. All TEAs recorded in the Dutch national registry between 2014 and 2020 were included. The Kaplan-Meier method was used for survival analysis, and a logistic regression model was used to assess the factors associated with revision. Results. A total of 514 TEAs were included, of which 35 were revised. The five-year implant survival was 91%. Male sex, a higher BMI, and previous surgery to the same elbow showed a statistically significant association with revision (p < 0.036). Of the 35 revised implants, ten (29%) underwent a second revision. Conclusion. This study reports a five-year implant survival of TEA of 91%. Patient factors associated with revision are defined and can be used to optimize informed consent and shared decision-making. There was a high rate of secondary revisions. Cite this article: Bone Jt Open 2023;4(2):110–119


Bone & Joint Open
Vol. 5, Issue 8 | Pages 637 - 643
6 Aug 2024
Abelleyra Lastoria DA Casey L Beni R Papanastasiou AV Kamyab AA Devetzis K Scott CEH Hing CB

Aims. Our primary aim was to establish the proportion of female orthopaedic consultants who perform arthroplasty via cases submitted to the National Joint Registry (NJR), which covers England, Wales, Northern Ireland, the Isle of Man, and Guernsey. Secondary aims included comparing time since specialist registration, private practice participation, and number of hospitals worked in between male and female surgeons. Methods. Publicly available data from the NJR was extracted on the types of arthroplasty performed by each surgeon, and the number of procedures of each type undertaken. Each surgeon was cross-referenced with the General Medical Council (GMC) website, using GMC number to extract surgeon demographic data. These included sex, region of practice, and dates of full and specialist registration. Results. Of 2,895 surgeons contributing to the NJR in 2023, 102 (4%) were female. The highest proportions of female surgeons were among those who performed elbow (n = 25; 5%), shoulder (n = 24; 4%), and ankle (n = 8; 4%) arthroplasty. Hip (n = 66; 3%) and knee arthroplasty (n = 39; 2%) had the lowest female representation. Female surgeons had been practising for a median of 10.4 years since specialist registration compared to 13.7 years for males (p < 0.001). Northern Ireland was the region with the highest proportion of female arthroplasty surgeons (8%). A greater proportion of male surgeons worked in private practice (63% vs 24%; p < 0.001) and in multiple hospitals (74% vs 40%; p < 0.001). Conclusion. Only 4% of surgeons currently contributing cases to the NJR are female, with the highest proportion performing elbow arthroplasty (5%). Female orthopaedic surgeons in the NJR are earlier in their careers than male surgeons, and are less involved in private practice. There is a wide geographical variation in the proportion of female arthroplasty surgeons. Cite this article: Bone Jt Open 2024;5(8):637–643


The Bone & Joint Journal
Vol. 106-B, Issue 12 | Pages 1461 - 1468
1 Dec 2024
Hamoodi Z Shapiro J Sayers A Whitehouse MR Watts AC

Aims. The aim of this audit was to assess and improve the completeness and accuracy of the National Joint Registry (NJR) dataset for arthroplasty of the elbow. Methods. It was performed in two phases. In Phase 1, the completeness was assessed by comparing the NJR elbow dataset with the NHS England Hospital Episode Statistics (HES) data between April 2012 and April 2020. In order to assess the accuracy of the data, the components of each arthroplasty recorded in the NJR were compared to the type of arthroplasty which was recorded. In Phase 2, a national collaborative audit was undertaken to evaluate the reasons for unmatched data, add missing arthroplasties, and evaluate the reasons for the recording of inaccurate arthroplasties and correct them. Results. Phase 1 identified 5,539 arthroplasties in HES which did not match an arthroplasty on the NJR, and 448 inaccurate arthroplasties from 254 hospitals. Most mismatched procedures (3,960 procedures; 71%) were radial head arthroplasties (RHAs). In Phase 2, 142 NHS hospitals with 3,640 (66%) mismatched and 314 (69%) inaccurate arthroplasties volunteered to assess their records. A large proportion of the unmatched data (3,000 arthroplasties; 82%) were confirmed as being missing from the NJR. The overall rate of completeness of the NJR elbow dataset improved from 63% to 83% following phase 2, and the completeness of total elbow arthroplasty data improved to 93%. Missing RHAs had the biggest impact on the overall completeness, but through the audit the number of RHAs in the NJR nearly doubled and completeness increased from 35% to 70%. The accuracy of data was 94% and improved to 98% after correcting 212 of the 448 inaccurately recorded arthroplasties. Conclusion. The rate of completeness of the NJR total elbow arthroplasty dataset is currently 93% and the accuracy is 98%. This audit identified challenges of data capture with regard to RHAs. Collaboration with a trauma and orthopaedic trainees through the British Orthopaedic Trainee Association improved the completeness and accuracy of the NJR elbow dataset, which will improve the validity of the reports and of the associated research. Cite this article: Bone Joint J 2024;106-B(12):1461–1468


Bone & Joint Open
Vol. 3, Issue 5 | Pages 367 - 374
5 May 2022
Sinagra ZP Davis JS Lorimer M de Steiger RN Graves SE Yates P Manning L

Aims. National joint registries under-report revisions for periprosthetic joint infection (PJI). We aimed to validate PJI reporting to the Australian Orthopaedic Association National Joint Arthroplasty Registry (AOANJRR) and the factors associated with its accuracy. We then applied these data to refine estimates of the total national burden of PJI. Methods. A total of 561 Australian cases of confirmed PJI were captured by a large, prospective observational study, and matched to data available for the same patients through the AOANJRR. Results. In all, 501 (89.3%) cases of PJI recruited to the prospective observational study were successfully matched with the AOANJRR database. Of these, 376 (75.0%) were captured by the registry, while 125 (25.0%) did not have a revision or reoperation for PJI recorded. In a multivariate logistic regression analysis, early (within 30 days of implantation) PJIs were less likely to be reported (adjusted odds ratio (OR) 0.56; 95% confidence interval (CI) 0.34 to 0.93; p = 0.020), while two-stage revision procedures were more likely to be reported as a PJI to the registry (OR 5.3 (95% CI 2.37 to 14.0); p ≤ 0.001) than debridement and implant retention or other surgical procedures. Based on this data, the true estimate of the incidence of PJI in Australia is up to 3,900 cases per year. Conclusion. In Australia, infection was not recorded as the indication for revision or reoperation in one-quarter of those with confirmed PJI. This is better than in other registries, but suggests that registry-captured estimates of the total national burden of PJI are underestimated by at least one-third. Inconsistent PJI reporting is multifactorial but could be improved by developing a nested PJI registry embedded within the national arthroplasty registry. Cite this article: Bone Jt Open 2022;3(5):367–373


The Bone & Joint Journal
Vol. 103-B, Issue 6 | Pages 1111 - 1118
1 Jun 2021
Dainty JR Smith TO Clark EM Whitehouse MR Price AJ MacGregor AJ

Aims. To determine the trajectories of patient reported pain and functional disability over five years following total hip arthroplasty (THA) or total knee arthroplasty (TKA). Methods. A prospective, longitudinal cohort sub-study within the National Joint Registry (NJR) was undertaken. In all, 20,089 patients who underwent primary THA and 22,489 who underwent primary TKA between 2009 and 2010 were sent Oxford Hip Score (OHS) and Oxford Knee Score (OKS) questionnaires at six months, and one, three, and five years postoperatively. OHS and OKS were disaggregated into pain and function subscales. A k-means clustering procedure assigned each patient to a longitudinal trajectory group for pain and function. Ordinal regression was used to predict trajectory group membership using baseline OHS and OKS score, age, BMI, index of multiple deprivation, sex, ethnicity, geographical location, and American Society of Anesthesiologists grade. Results. Data described two discrete trajectories for pain and function: ‘level 1’ responders (around 70% of cases) in whom a high level of improvement is sustained over five years, and ‘level 2’ responders who had sustained improvement, but at a lower level. Baseline patient variables were only weak predictors of pain trajectory and modest predictors of function trajectory. Those with worse baseline pain and function tended to show a greater likelihood of following a ‘level 2’ trajectory. Six-month patient-reported outcome measures data reliably predicted the class of five-year outcome trajectory for both pain and function. Conclusion. The available preoperative patient variables were not reliable predictors of postoperative pain and function after THA and TKA. Reviewing patient outcomes at six months postoperatively is a reliable indicator of outcome at five years. Cite this article: Bone Joint J 2021;103-B(6):1111–1118


The Bone & Joint Journal
Vol. 98-B, Issue 1 | Pages 33 - 39
1 Jan 2016
Sabah SA Henckel J Koutsouris S Rajani R Hothi H Skinner JA Hart AJ

Aims

The National Joint Registry for England, Wales and Northern Ireland (NJR) has extended its scope to report on hospital, surgeon and implant performance. Data linkage of the NJR to the London Implant Retrieval Centre (LIRC) has previously evaluated data quality for hip primary procedures, but did not assess revision records.

Methods

We analysed metal-on-metal hip revision procedures performed between 2003 and 2013. A total of 69 929 revision procedures from the NJR and 929 revised pairs of components from the LIRC were included.


The Bone & Joint Journal
Vol. 104-B, Issue 5 | Pages 613 - 619
2 May 2022
Ackerman IN Busija L Lorimer M de Steiger R Graves SE

Aims. This study aimed to describe the use of revision knee arthroplasty in Australia and examine changes in lifetime risk over a decade. Methods. De-identified individual-level data on all revision knee arthroplasties performed in Australia from 2007 to 2017 were obtained from the Australian Orthopaedic Association National Joint Replacement Registry. Population data and life tables were obtained from the Australian Bureau of Statistics. The lifetime risk of revision surgery was calculated for each year using a standardized formula. Separate calculations were undertaken for males and females. Results. In total, 43,188 revision knee arthroplasty procedures were performed in Australia during the study period, with a median age at surgery of 69 years (interquartile range (IQR) 62 to 76). In 2017, revision knee arthroplasty rates were highest for males aged 70 to 79 years (102.9 procedures per 100,000 population). Lifetime risk of revision knee arthroplasty for females increased slightly from 1.61% (95% confidence interval (CI) 1.53% to 1.69%) in 2007 to 2.22% (95% CI 2.13% to 2.31%) in 2017. A similar pattern was evident for males, with a lifetime risk of 1.43% (95% CI 1.36% to 1.51%) in 2007 and 2.02% (95% CI 1.93% to 2.11%) in 2017. A decline in procedures performed for loosening/lysis (from 41% in 2007 to 24% in 2017) and pain (from 14% to 9%) was evident, while infection became an increasingly common indication (from 19% in 2007 to 29% in 2017). Conclusion. Well-validated national registry data can help us understand the epidemiology of revision knee arthroplasty, including changing clinical indications. Despite a small increase over a decade, the lifetime risk of revision knee arthroplasty in Australia is low at one in 45 females and one in 50 males. These methods offer a population-level approach to quantifying revision burden that can be used for ongoing national surveillance and between-country comparisons. Cite this article: Bone Joint J 2022;104-B(5):613–619


Bone & Joint Research
Vol. 9, Issue 10 | Pages 635 - 644
1 Oct 2020
Lemaignen A Grammatico-Guillon L Astagneau P Marmor S Ferry T Jolivet-Gougeon A Senneville E Bernard L

Aims. The French registry for complex bone and joint infections (C-BJIs) was created in 2012 in order to facilitate a homogeneous management of patients presented for multidisciplinary advice in referral centres for C-BJI, to monitor their activity and to produce epidemiological data. We aimed here to present the genesis and characteristics of this national registry and provide the analysis of its data quality. Methods. A centralized online secured database gathering the electronic case report forms (eCRFs) was filled for every patient presented in multidisciplinary meetings (MM) among the 24 French referral centres. Metrics of this registry were described between 2012 and 2016. Data quality was assessed by comparing essential items from the registry with a controlled dataset extracted from medical charts of a random sample of patients from each centre. Internal completeness and consistency were calculated. Results. Between 2012 and 2016, 30,607 presentations in MM were recorded corresponding to 17,748 individual patients (mean age 62.1 years (SD 18.4); 10,961 (61.8%) males). BJI was considered as complex for 63% of cases (n = 19,355), and 13,376 (44%) had prosthetic joint infections (PJIs). The controlled dataset, available for 19 centres, included 283 patients. Global consistency and completeness were estimated at 88.2% and 88.9%, respectively, considering missing items in the eCRFs as negative results. Conclusion. This national registry is one of the largest prospective databases on BJI and its acceptable data quality parameters allow further use for epidemiological purposes. Cite this article: Bone Joint Res 2020;9(9):635–644


The Bone & Joint Journal
Vol. 107-B, Issue 1 | Pages 27 - 33
1 Jan 2025
Mc Donald S Yoong A Evans JT Farrow L

Aims. The Exeter femoral stem has a cemented, polished taper-slip design, and an excellent track record. The current range includes short-length options for various offsets, but less is known about the performance of these stems. The aim of this study was to compare the survival of short-length stems with standard-length Exeter stems. Methods. A systematic review of all studies reporting the use of short-length Exeter stems in primary total hip arthroplasty (THA) was undertaken. Survival data, the indication for revision, and patient-reported outcomes were gathered from observational and randomized studies. Studies based on registry data were analyzed separately. Results. The review included nine studies which covered a total of 2,190 short stems. The mean follow-up was 6.4 years (2 to 12) with an all-cause survival of 95.4%. When revisions due to aseptic acetabular loosening were excluded, the survival was 97.7%. Four stems fractured (0.18%). The mean Oxford Hip Score improved from 18.29 (1.33 to 21.6) preoperatively to 41.59 (32.9 to 43.4) at final follow-up. Three studies used data from national registries. A total of 25,895 short stems (offset ≤ 35.5 mm) were used compared with 336,218 standard-length stems. In these studies, short stems had a hazard ratio (HR) for all-cause survival of 1.19 (95% CI 0.96 to 1.43) with a rate of revision per 1,000 component-years of 0.037 compared with 0.035 for standard-length stems. One study from the New Zealand Joint Registry divided short stems into standard and small offset groups. Standard offset short stems (≥ 37.5 mm) had a 0.84 HR (95% CI 0.38 to 1.88) while small offset short stems (≤ 35.5 mm) had a 1.6 HR compared with standard stems (95% CI 1.3 to 1.98). Conclusion. Short Exeter stems perform well and are a safe femoral component in primary THA, according to the current literature. There does not appear to be an increased risk of implant fracture associated with these stems. Cite this article: Bone Joint J 2025;107-B(1):27–33


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 834 - 841
1 Aug 2024
French JMR Deere K Jones T Pegg DJ Reed MR Whitehouse MR Sayers A

Aims. The COVID-19 pandemic has disrupted the provision of arthroplasty services in England, Wales, and Northern Ireland. This study aimed to quantify the backlog, analyze national trends, and predict time to recovery. Methods. We performed an analysis of the mandatory prospective national registry of all independent and publicly funded hip, knee, shoulder, elbow, and ankle replacements in England, Wales, and Northern Ireland between January 2019 and December 2022 inclusive, totalling 729,642 operations. The deficit was calculated per year compared to a continuation of 2019 volume. Total deficit of cases between 2020 to 2022 was expressed as a percentage of 2019 volume. Sub-analyses were performed based on procedure type, country, and unit sector. Results. Between January 2020 and December 2022, there was a deficit of 158,994 joint replacements. This is equivalent to over two-thirds of a year of normal expected operating activity (71.6%). There were 104,724 (-47.1%) fewer performed in 2020, 41,928 (-18.9%) fewer performed in 2021, and 12,342 (-5.6%) fewer performed in 2022, respectively, than in 2019. Independent-sector procedures increased to make it the predominant arthroplasty provider (53% in 2022). NHS activity was 73.2% of 2019 levels, while independent activity increased to 126.8%. Wales (-136.3%) and Northern Ireland (-121.3%) recorded deficits of more than a year’s worth of procedures, substantially more than England (-66.7%). It would take until 2031 to eliminate this deficit with an immediate expansion of capacity over 2019 levels by 10%. Conclusion. The arthroplasty deficit following the COVID-19 pandemic is now equivalent to over two-thirds of a year of normal operating activity, and continues to increase. Patients awaiting different types of arthroplasty, in each country, have been affected disproportionately. A rapid and significant expansion in services is required to address the deficit, and will still take many years to rectify. Cite this article: Bone Joint J 2024;106-B(8):834–841


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1074 - 1083
1 Oct 2024
Sørensen RR Timm S Rasmussen LE Brasen CL Varnum C

Aims. The influence of metabolic syndrome (MetS) on the outcome after hip and knee arthroplasty is debated. We aimed to investigate the change in patient-reported outcome measure (PROM) scores after hip and knee arthroplasty, comparing patients with and without MetS. Methods. From 1 May 2017 to 30 November 2019, a prospective cohort of 2,586 patients undergoing elective unilateral hip and knee arthroplasty was established in Denmark. Data from national registries and a local database were used to determine the presence of MetS. Patients’ scores on Oxford Hip Score (OHS) or Oxford Knee Score (OKS), EuroQol five-dimension five-level questionnaire (EQ-5D-5L), University of California, Los Angeles (UCLA) Activity Scale, and Forgotten Joint Score (FJS) at baseline, three, 12, and 24 months after surgery were collected. Primary outcome was the difference between groups from baseline to 12 months in OHS and OKS. Secondary outcomes were scores of OHS and OKS at three and 24 months and EQ-5D-5L, UCLA Activity Scale, and FJS at three, 12, and 24 months after surgery. Generalized linear mixed model was applied, adjusting for age, sex, Charlson Comorbidity Index, and smoking to present marginal mean and associated 95% CIs. Results. A total of 62.3% (1,611/2,586) of the cohort met the criteria for MetS. Both groups showed similar increase in mean OHS (MetS group 22.5 (95% CI 21.8 to 23.1), non-MetS group 22.1 (21.3 to 22.8); p = 0.477) and mean OKS (MetS group 18.0 (17.4 to 18.6), non-MetS group 17.8 (17.0 to 18.7); p = 0.722) at 12 months' follow-up. Between groups, similar improvements were seen for OHS and OKS at three and 24 months postoperatively and for the mean EQ-5D-5L, EuroQol-visual analogue scale (EQ-VAS), UCLA Activity Scale, and FJS at every timepoint. Conclusion. Patients meeting the criteria for MetS obtain the same improvement in PROM scores as individuals without MetS up to 24 months after hip and knee arthroplasty. This is important for the clinician to take into account when assessing and advising patients with MetS. Cite this article: Bone Joint J 2024;106-B(10):1074–1083


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 221 - 226
1 Mar 2023
Wilton T Skinner JA Haddad FS

Recent publications have drawn attention to the fact that some brands of joint replacement may contain variants which perform significantly worse (or better) than their ‘siblings’. As a result, the National Joint Registry has performed much more detailed analysis on the larger families of knee arthroplasties in order to identify exactly where these differences may be present and may hitherto have remained hidden. The analysis of the Nexgen knee arthroplasty brand identified that some posterior-stabilized combinations have particularly high revision rates for aseptic loosening of the tibia, and consequently a medical device recall has been issued for the Nexgen ‘option’ tibial component which was implicated. More elaborate signal detection is required in order to identify such variation in results in a routine fashion if patients are to be protected from such variation in outcomes between closely related implant types. Cite this article: Bone Joint J 2023;105-B(3):221–226


Bone & Joint 360
Vol. 13, Issue 3 | Pages 31 - 34
3 Jun 2024

The June 2024 Shoulder & Elbow Roundup. 360. looks at: Reverse versus anatomical total shoulder replacement for osteoarthritis? A UK national picture; Acute rehabilitation following traumatic anterior shoulder dislocation (ARTISAN): pragmatic, multicentre, randomized controlled trial; acid for rotator cuff repair: a systematic review and meta-analysis of randomized controlled trials; Metal or ceramic humeral head total shoulder arthroplasty: an analysis of data from the National Joint Registry; Platelet-rich plasma has better results for long-term functional improvement and pain relief for lateral epicondylitis: a systematic review and meta-analysis of randomized controlled trials; Quantitative fatty infiltration and 3D muscle volume after nonoperative treatment of symptomatic rotator cuff tears: a prospective MRI study of 79 patients; Locking plates for non-osteoporotic proximal humeral fractures in the long term; A systematic review of the treatment of primary acromioclavicular joint osteoarthritis


The Bone & Joint Journal
Vol. 103-B, Issue 10 | Pages 1555 - 1560
4 Oct 2021
Phillips JRA Tucker K

Aims. Knee arthroplasty surgery is a highly effective treatment for arthritis and disorders of the knee. There are a wide variety of implant brands and types of knee arthroplasty available to surgeons. As a result of a number of highly publicized failures, arthroplasty surgery is highly regulated in the UK and many other countries through national registries, introduced to monitor implant performance, surgeons, and hospitals. With time, the options available within many brand portfolios have grown, with alternative tibial or femoral components, tibial insert materials, or shapes and patella resurfacings. In this study we have investigated the effect of the expansion of implant brand portfolios and where there may be a lack of transparency around a brand name. We also aimed to establish the potential numbers of compatible implant construct combinations. Methods. Hypothetical implant brand portfolios were proposed, and the number of compatible implant construct combinations was calculated. Results. A simple knee portfolio with cemented cruciate-retaining (CR) and posterior-stabilized (PS) components, with and without a patella, has four combinations. If there are two options available for each component, the numbers double for each option, resulting in 32 combinations. The effect of adding a third option multiplies the number by 1.3. Introducing compatible uncemented options, with the effect of hybrids, multiplies the number by 4. An implant portfolio with two femoral components (both in CR and PS), with two insert options and a patella, all in cemented and uncemented versions leads to 192 possible compatible implant construct combinations. There are implant brands available to surgeons with many more than two options. Conclusion. This study demonstrates that the addition of multiple variants within a knee brand portfolio leads to a large number (many hundreds) of compatible implant construct combinations. Revision rates of implant combinations are not currently reviewed at this level of granularity, leading to the risk of camouflage of true outcomes. Cite this article: Bone Joint J 2021;103-B(10):1555–1560


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 127 - 133
1 Jan 2022
Viberg B Pedersen AB Kjærsgaard A Lauritsen J Overgaard S

Aims. The aim of this study was to assess the association of mortality and reoperation when comparing cemented and uncemented hemiarthroplasty (HA) in hip fracture patients aged over 65 years. Methods. This was a population-based cohort study on hip fracture patients using prospectively gathered data from several national registries in Denmark from 2004 to 2015 with up to five years follow-up. The primary outcome was mortality and the secondary outcome was reoperation. Hazard ratios (HRs) for mortality and subdistributional hazard ratios (sHRs) for reoperations are shown with 95% confidence intervals (CIs). Results. A total of 17,671 patients with primary HA were identified (9,484 uncemented and 8,187 cemented HAs). Compared to uncemented HA, surgery with cemented HA was associated with an absolute risk difference of 0.4% for mortality within the period zero to one day after surgery and an adjusted HR of 1.70 (95% CI 1.22 to 2.38). After seven days, there was no longer any association, with an adjusted HR of 1.07 (95% CI 0.90 to 1.28). This continued until five years after surgery with a HR of 1.01 (95% CI 0.96 to 1.06). There was a higher proportion of reoperations due to any reason after five years in the uncemented group with 10.2% compared to the cemented group with 6.1%. This yielded an adjusted sHR of 0.65 (95% CI 0.57 to 0.75) and difference continued up until five years after the surgery, demonstrating a sHR of 0.70 (95% CI 0.59 to 0.83). Conclusion. In a non-selected cohort of hip fracture patients, surgery with cemented HA was associated with a higher relative mortality during the first postoperative day compared to surgery with uncemented HA, but there was no difference after seven days up until five years after. In contrast, surgery with cemented HA was associated with lower risk of reoperation up to five years postoperatively compared with surgery with uncemented HA. There was a higher relative mortality on the first postoperative day for cemented HA versus uncemented HA. There was no difference in mortality after seven days up until five years after surgery. There were 6.1% reoperations for cemented HA compared to 10.2% for uncemented HA after five years. Cite this article: Bone Joint J 2022;104-B(1):127–133


Bone & Joint Open
Vol. 4, Issue 10 | Pages 776 - 781
16 Oct 2023
Matar HE Bloch BV James PJ

Aims. The aim of this study was to evaluate medium- to long-term outcomes and complications of the Stanmore Modular Individualised Lower Extremity System (SMILES) rotating hinge implant in revision total knee arthroplasty (rTKA) at a tertiary unit. It is hypothesized that this fully cemented construct leads to satisfactory clinical outcomes. Methods. A retrospective consecutive study of all patients who underwent a rTKA using the fully cemented SMILES rotating hinge prosthesis between 2005 to 2018. Outcome measures included aseptic loosening, reoperations, revision for any cause, complications, and survivorship. Patients and implant survivorship data were identified through both prospectively collected local hospital electronic databases and linked data from the National Joint Registry/NHS Personal Demographic Service. Kaplan-Meier survival analysis was used at ten years. Results. Overall, 69 consecutive patients (69 knees) were included with a median age of 78 years (interquartile range 69 to 84), and there were 46 females (66.7%). Indications were septic revisions in 26 (37.7%), and aseptic aetiology in the remining 43 (62.3%). The mean follow-up was 9.7 years (4 to 18), and the overall complication was rate was 7.24%, all with patellofemoral complications. Failure rate with ‘any cause revision’ was 5.8%. There was one case of aseptic loosening of the femoral component. At ten years, 17/69 patients (24.63%) had died, and implant survivorship was 92.2%. Conclusion. In our experience, the SMILES rotating hinge prosthesis achieves satisfactory long-term outcomes with ten-year implant survivorship of 92.2% and a patellofemoral complication rate of 7.24%. Cite this article: Bone Jt Open 2023;4(10):776–781


Bone & Joint Open
Vol. 4, Issue 9 | Pages 682 - 688
6 Sep 2023
Hampton M Balachandar V Charalambous CP Sutton PM

Aims. Aseptic loosening is the most common cause of failure following cemented total knee arthroplasty (TKA), and has been linked to poor cementation technique. We aimed to develop a consensus on the optimal technique for component cementation in TKA. Methods. A UK-based, three-round, online modified Delphi Expert Consensus Study was completed focusing on cementation technique in TKA. Experts were identified as having a minimum of five years’ consultant experience in the NHS and fulfilling any one of the following criteria: a ‘high volume’ knee arthroplasty practice (> 150 TKAs per annum) as identified from the National joint Registry of England, Wales, Northern Ireland and the Isle of Man; a senior author of at least five peer reviewed articles related to TKA in the previous five years; a surgeon who is named trainer for a post-certificate of comletion of training fellowship in TKA. Results. In total, 81 experts (round 1) and 80 experts (round 2 and 3) completed the Delphi Study. Four domains with a total of 24 statements were identified. 100% consensus was reached within the cement preparation, pressurization, and cement curing domains. 90% consensus was reached within the cement application domain. Consensus was not reached with only one statement regarding the handling of cement during initial application to the tibial and/or femoral bone surfaces. Conclusion. The Cementing Techniques In Knee Surgery (CeTIKS) Delphi consensus study presents comprehensive recommendations on the optimal technique for component cementing in TKA. Expert opinion has a place in the hierarchy of evidence and, until better evidence is available these recommendations should be considered when cementing a TKA. Cite this article: Bone Jt Open 2023;4(9):682–688


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 121 - 129
1 Mar 2024
Orce Rodríguez A Smith PN Johnson P O'Sullivan M Holder C Shimmin A

Aims. In recent years, the use of a collared cementless femoral prosthesis has risen in popularity. The design intention of collared components is to transfer some load to the resected femoral calcar and prevent implant subsidence within the cancellous bone of the metaphysis. Conversely, the load transfer for a cemented femoral prosthesis depends on the cement-component and cement-bone interface interaction. The aim of our study was to compare the three most commonly used collared cementless components and the three most commonly used tapered polished cemented components in patients aged ≥ 75 years who have undergone a primary total hip arthroplasty (THA) for osteoarthritis (OA). Methods. Data from the Australian Orthopaedic Association National Joint Replacement Registry from 1 September 1999 to 31 December 2022 were analyzed. Collared cementless femoral components and cemented components were identified, and the three most commonly used components in each group were analyzed. We identified a total of 11,278 collared cementless components and 47,835 cemented components. Hazard ratios (HRs) from Cox proportional hazards models, adjusting for age and sex, were obtained to compare the revision rates between the groups. Results. From six months postoperatively onwards, patients aged ≥ 75 years undergoing primary THA with primary diagnosis of OA have a lower risk of all-cause revision with collared cementless components than with a polished tapered cemented component (HR 0.78 (95% confidence interval 0.64 to 0.96); p = 0.018). There is no difference in revision rate prior to six months. Conclusion. Patients aged ≥ 75 years with a primary diagnosis of OA have a significantly lower rate of revision with the most common collared cementless femoral component, compared with the most common polished tapered cemented components from six months postoperatively onwards. The lower revision rate is largely due to a reduction in revisions for fracture and infection. Cite this article: Bone Joint J 2024;106-B(3 Supple A):121–129


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 301 - 306
1 Mar 2023
Jennison T Ukoumunne O Lamb S Sharpe I Goldberg AJ

Aims. Despite the increasing numbers of ankle arthroplasties, there are limited studies on their survival and comparisons between different implants. The primary aim of this study was to determine the failure rates of primary ankle arthroplasties commonly used in the UK. Methods. A data linkage study combined National Joint Registry (NJR) data and NHS Digital data. The primary outcome of failure was defined as the removal or exchange of any components of the implanted device. Life tables and Kaplan-Meier survival charts were used to illustrate survivorship. Cox proportional hazards regression models were fitted to compare failure rates between 1 April 2010 and 31 December 2018. Results. Overall, 5,562 primary ankle arthroplasties were recorded in the NJR. Linked data show a one-year survivorship of 98.8% (95% confidence interval (CI) 98.4% to 99.0%), five-year survival in 2,725 patients of 90.2% (95% CI 89.2% to 91.1%), and ten-year survival in 199 patients of 86.2% (95% CI 84.6% to 87.6%). The five-year survival for fixed-bearing implants was 94.3% (95% CI 91.3% to 96.3%) compared to 89.4% (95% CI 88.3% to 90.4%) for mobile-bearing implants. A Cox regression model for all implants with over 100 implantations using the implant with the best survivorship (Infinity) as the reference, only the STAR (hazard ratio (HR) 1.60 (95% CI 0.87 to 2.96)) and INBONE (HR 0.38 (95% CI 0.05 to 2.84)) did not demonstrate worse survival at three and five years. Conclusion. Ankle arthroplasties in the UK have a five-year survival rate of 90.2%, which is lower than recorded on the NJR, because we have shown that approximately one-third of ankle arthroplasty failures are not reported to the NJR. There are statistically significant differences in survival between different implants. Fixed-bearing implants appear to demonstrate higher survivorship than mobile-bearing implants. Cite this article: Bone Joint J 2023;105-B(3):301–306


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 504 - 510
1 May 2023
Evans JT Salar O Whitehouse SL Sayers A Whitehouse MR Wilton T Hubble MJW

Aims. The Exeter V40 femoral stem is the most implanted stem in the National Joint Registry (NJR) for primary total hip arthroplasty (THA). In 2004, the 44/00/125 stem was released for use in ‘cement-in-cement’ revision cases. It has, however, been used ‘off-label’ as a primary stem when patient anatomy requires a smaller stem with a 44 mm offset. We aimed to investigate survival of this implant in comparison to others in the range when used in primary THAs recorded in the NJR. Methods. We analyzed 328,737 primary THAs using the Exeter V40 stem, comprising 34.3% of the 958,869 from the start of the NJR to December 2018. Our exposure was the stem, and the outcome was all-cause construct revision. We stratified analyses into four groups: constructs using the 44/00/125 stem, those using the 44/0/150 stem, those including a 35.5/125 stem, and constructs using any other Exeter V40 stem. Results. In all 328,737 THAs using an Exeter V40 stem, the revision estimate was 2.8% (95% confidence interval (CI) 2.7 to 2.8). The 44/00/125 stem was implanted in 2,158 primary THAs, and the ten-year revision estimate was 4.9% (95% CI 3.6 to 6.8). Controlling for age, sex, year of operation, indication, and American Society of Anesthesiologists grade demonstrated an increased overall hazard of revision for constructs using the 44/00/125 stem compared to constructs using other Exeter V40 femoral stems (hazard ratio 1.8 (95% CI 1.4 to 2.3)). Conclusion. Although the revision estimate is within the National Institute for Health and Care Excellence ten-year benchmark, survivorship of constructs using the 44/00/125 stem appears to be lower than the rest of the range. Adjusted analyses will not take into account ‘confounding by indication’, e.g. patients with complex anatomy who may have a higher risk of revision. Surgeons and patients should be reassured but be aware of the observed increased revision estimate, and only use this stem when other implants are not suitable. Cite this article: Bone Joint J 2023;105-B(5):504–510


Bone & Joint Open
Vol. 3, Issue 9 | Pages 716 - 725
15 Sep 2022
Boulton C Harrison C Wilton T Armstrong R Young E Pegg D Wilkinson JM

Data of high quality are critical for the meaningful interpretation of registry information. The National Joint Registry (NJR) was established in 2002 as the result of an unexpectedly high failure rate of a cemented total hip arthroplasty. The NJR began data collection in 2003. In this study we report on the outcomes following the establishment of a formal data quality (DQ) audit process within the NJR, within which each patient episode entry is validated against the hospital unit’s Patient Administration System and vice-versa. This process enables bidirectional validation of every NJR entry and retrospective correction of any errors in the dataset. In 2014/15 baseline average compliance was 92.6% and this increased year-on-year with repeated audit cycles to 96.0% in 2018/19, with 76.4% of units achieving > 95% compliance. Following the closure of the audit cycle, an overall compliance rate of 97.9% was achieved for the 2018/19 period. An automated system was initiated in 2018 to reduce administrative burden and to integrate the DQ process into standard workflows. Our processes and quality improvement results demonstrate that DQ may be implemented successfully at national level, while minimizing the burden on hospitals. Cite this article: Bone Jt Open 2022;3(9):716–725


Bone & Joint 360
Vol. 12, Issue 6 | Pages 20 - 23
1 Dec 2023

The December 2023 Knee Roundup. 360. looks at: Obesity is associated with greater improvement in patient-reported outcomes following primary total knee arthroplasty; Does mild flexion of the femoral prosthesis in total knee arthroplasty result in better early postoperative outcomes?; Robotic or manual total knee arthroplasty: a randomized controlled trial; Patient-relevant outcomes following first revision total knee arthroplasty, by diagnosis: an analysis of implant survivorship, mortality, serious medical complications, and patient-reported outcome measures using the National Joint Registry data set; Sagittal alignment in total knee arthroplasty: are there any discrepancies between robotic-assisted and manual axis orientation?; Tourniquet use does not impact recovery trajectory in total knee arthroplasty; Impact of proximal tibial varus anatomy on survivorship after medial unicondylar knee arthroplasty; Bone cement directly to the implant in primary total knee arthroplasty?; Maintaining joint line obliquity optimizes outcomes in patients with constitutionally varus knees


The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 482 - 491
1 May 2024
Davies A Sabharwal S Liddle AD Zamora Talaya MB Rangan A Reilly P

Aims. Metal and ceramic humeral head bearing surfaces are available choices in anatomical shoulder arthroplasties. Wear studies have shown superior performance of ceramic heads, however comparison of clinical outcomes according to bearing surface in total shoulder arthroplasty (TSA) and hemiarthroplasty (HA) is limited. This study aimed to compare the rates of revision and reoperation following metal and ceramic humeral head TSA and HA using data from the National Joint Registry (NJR), which collects data from England, Wales, Northern Ireland, Isle of Man and the States of Guernsey. Methods. NJR shoulder arthroplasty records were linked to Hospital Episode Statistics and the National Mortality Register. TSA and HA performed for osteoarthritis (OA) in patients with an intact rotator cuff were included. Metal and ceramic humeral head prostheses were matched within separate TSA and HA groups using propensity scores based on 12 and 11 characteristics, respectively. The primary outcome was time to first revision and the secondary outcome was non-revision reoperation. Results. A total of 4,799 TSAs (3,578 metal, 1,221 ceramic) and 1,363 HAs (1,020 metal, 343 ceramic) were included. The rate of revision was higher for metal compared with ceramic TSA, hazard ratio (HR) 3.31 (95% confidence interval (CI) 1.67 to 6.58). At eight years, prosthesis survival for ceramic TSA was 98.7% (95% CI 97.3 to 99.4) compared with 96.4% (95% CI 95.2 to 97.3) for metal TSA. The majority of revision TSAs were for cuff insufficiency or instability/dislocation. There was no significant difference in the revision rate for ceramic compared with metal head HA (HR 1.33 (95% CI 0.76 to 2.34)). For ceramic HA, eight-year prosthetic survival was 92.8% (95% CI 86.9 to 96.1), compared with 91.6% (95% CI 89.3 to 93.5) for metal HA. The majority of revision HAs were for cuff failure. Conclusion. The rate of all-cause revision was higher following metal compared with ceramic humeral head TSA in patients with OA and an intact rotator cuff. There was no difference in the revision rate for HA according to bearing surface. Cite this article: Bone Joint J 2024;106-B(5):482–491


Bone & Joint Research
Vol. 13, Issue 8 | Pages 392 - 400
5 Aug 2024
Barakat A Evans J Gibbons C Singh HP

Aims. The Oxford Shoulder Score (OSS) is a 12-item measure commonly used for the assessment of shoulder surgeries. This study explores whether computerized adaptive testing (CAT) provides a shortened, individually tailored questionnaire while maintaining test accuracy. Methods. A total of 16,238 preoperative OSS were available in the National Joint Registry (NJR) for England, Wales, Northern Ireland, the Isle of Man, and the States of Guernsey dataset (April 2012 to April 2022). Prior to CAT, the foundational item response theory (IRT) assumptions of unidimensionality, monotonicity, and local independence were established. CAT compared sequential item selection with stopping criteria set at standard error (SE) < 0.32 and SE < 0.45 (equivalent to reliability coefficients of 0.90 and 0.80) to full-length patient-reported outcome measure (PROM) precision. Results. Confirmatory factor analysis (CFA) for unidimensionality exhibited satisfactory fit with root mean square standardized residual (RSMSR) of 0.06 (cut-off ≤ 0.08) but not with comparative fit index (CFI) of 0.85 or Tucker-Lewis index (TLI) of 0.82 (cut-off > 0.90). Monotonicity, measured by H value, yielded 0.482, signifying good monotonic trends. Local independence was generally met, with Yen’s Q3 statistic > 0.2 for most items. The median item count for completing the CAT simulation with a SE of 0.32 was 3 (IQR 3 to 12), while for a SE of 0.45 it was 2 (IQR 2 to 6). This constituted only 25% and 16%, respectively, when compared to the 12-item full-length questionnaire. Conclusion. Calibrating IRT for the OSS has resulted in the development of an efficient and shortened CAT while maintaining accuracy and reliability. Through the reduction of redundant items and implementation of a standardized measurement scale, our study highlights a promising approach to alleviate time burden and potentially enhance compliance with these widely used outcome measures. Cite this article: Bone Joint Res 2024;13(8):392–400


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1312 - 1320
1 Nov 2024
Hamoodi Z Sayers A Whitehouse MR Rangan A Kearsley-Fleet L Sergeant J Watts AC

Aims. The aim of this study was to review the provision of total elbow arthroplasties (TEAs) in England, including the incidence, the characteristics of the patients and the service providers, the types of implant, and the outcomes. Methods. We analyzed the primary TEAs recorded in the National Joint Registry (NJR) between April 2012 and December 2022, with mortality data from the Civil Registration of Deaths dataset. Linkage with Hospital Episode Statistics-Admitted Patient Care (HES-APC) data provided further information not collected by the NJR. The incidences were calculated using estimations of the populations from the Office for National Statistics. The annual number of TEAs performed by surgeons and hospitals was analyzed on a national and regional basis. Results. A total of 3,891 primary TEAs were included. The annual incidence of TEA was between 0.72 and 0.82 per 100,000 persons before 2020 and declined to 0.4 due to a decrease in elective TEAs during the COVID-19 pandemic, with a slight recovery in 2022. Older patients, those of white ethnicity and females, were more likely to undergo TEA. Those who underwent elective TEA had a median wait of between 89 (IQR 41 to 221) and 122 days (IQR 74 to 189) in the years before 2021, and this increased to 183 days (IQR 66 to 350) in 2021. The number of TEAs performed by surgeons per annum remained unchanged, with a median of two (IQR 1 to 3). The median annual number of TEAs per region was three to six times higher than the median annual case load of the highest volume hospital in a region. Patients in the lowest socioeconomic group had a higher rate of serious adverse events and mortality (11%) when undergoing TEA for acute trauma. Conclusion. In England, TEA is more common in older age groups, those of white ethnicity, and females. The COVID-19 pandemic affected the incidence of elective TEA and waiting times, and the provision of TEA has not yet recovered. The Getting it Right First Time recommendation of centralizing services to one centre per region could result in up to a six-fold increase in the number of TEAs being performed in some centres. Cite this article: Bone Joint J 2024;106-B(11):1312–1320


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1050 - 1058
1 Oct 2024
Holleyman RJ Jameson SS Meek RMD Khanduja V Reed MR Judge A Board TN

Aims. This study evaluates the association between consultant and hospital volume and the risk of re-revision and 90-day mortality following first-time revision of primary hip arthroplasty for aseptic loosening. Methods. We conducted a cohort study of first-time, single-stage revision hip arthroplasties (RHAs) performed for aseptic loosening and recorded in the National Joint Registry (NJR) data for England, Wales, Northern Ireland, and the Isle of Man between 2003 and 2019. Patient identifiers were used to link records to national mortality data, and to NJR data to identify subsequent re-revision procedures. Multivariable Cox proportional hazard models with restricted cubic splines were used to define associations between volume and outcome. Results. Among 12,961 RHAs there were 513 re-revisions within two years, and 95 deaths within 90 days of surgery. The risk of re-revision was highest for a consultant’s first RHA (hazard ratio (HR) 1.56 (95% CI 1.15 to 2.12)) and remained significantly elevated for their first 24 cases (HR 1.26 (95% CI 1.00 to 1.58)). Annual consultant volumes of five/year were associated with an almost 30% greater risk of re-revision (HR 1.28 (95% CI 1.00 to 1.64)) and 80% greater risk of 90-day mortality (HR 1.81 (95% CI 1.02 to 3.21)) compared to volumes of 20/year. RHAs performed at hospitals which had cumulatively undertaken fewer than 167 RHAs were at up to 70% greater risk of re-revision (HR 1.70 (95% CI 1.12 to 2.59)), and those having undertaken fewer than 307 RHAs were at up to three times greater risk of 90-day mortality (HR 3.05 (95% CI 1.19 to 7.82)). Conclusion. This study found a significantly higher risk of re-revision and early postoperative mortality following first-time single-stage RHA for aseptic loosening when performed by lower-volume consultants and at lower-volume institutions, supporting the move towards the centralization of such cases towards higher-volume units and surgeons. Cite this article: Bone Joint J 2024;106-B(10):1050–1058


Bone & Joint Research
Vol. 12, Issue 5 | Pages 321 - 330
9 May 2023
Lenguerrand E Whitehouse MR Beswick AD Kunutsor SK Webb JCJ Mehendale S Porter M Blom AW

Aims. We compared the risks of re-revision and mortality between two-stage and single-stage revision surgeries among patients with infected primary hip arthroplasty. Methods. Patients with a periprosthetic joint infection (PJI) of their primary arthroplasty revised with single-stage or two-stage procedure in England and Wales between 2003 and 2014 were identified from the National Joint Registry. We used Poisson regression with restricted cubic splines to compute hazard ratios (HRs) at different postoperative periods. The total number of revisions and re-revisions undergone by patients was compared between the two strategies. Results. In total, 535 primary hip arthroplasties were revised with single-stage procedure (1,525 person-years) and 1,605 with two-stage procedure (5,885 person-years). All-cause re-revision was higher following single-stage revision, especially in the first three months (HR at 3 months = 1.98 (95% confidence interval (CI) 1.14 to 3.43), p = 0.009). The risks were comparable thereafter. Re-revision for PJI was higher in the first three postoperative months for single-stage revision and waned with time (HR at 3 months = 1.81 (95% CI 1.22 to 2.68), p = 0.003; HR at 6 months = 1.25 (95% CI 0.71 to 2.21), p = 0.441; HR at 12 months = 0.94 (95% CI 0.54 to 1.63), p = 0.819). Patients initially managed with a single-stage revision received fewer revision operations (mean 1.3 (SD 0.7) vs 2.2 (SD 0.6), p < 0.001). Mortality rates were comparable between these two procedures (29/10,000 person-years vs 33/10,000). Conclusion. The risk of unplanned re-revision was lower following two-stage revision, but only in the early postoperative period. The lower overall number of revision procedures associated with a single-stage revision strategy and the equivalent mortality rates to two-stage revision are reassuring. With appropriate counselling, single-stage revision is a viable option for the treatment of hip PJI. Cite this article: Bone Joint Res 2023;12(5):321–330


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 994 - 999
1 Sep 2024
El-Khaldi I Gude MH Gundtoft PH Viberg B

Aims. Pneumatic tourniquets are often used during the surgical treatment of unstable traumatic ankle fractures. The aim of this study was to assess the risk of reoperation after open reduction and internal fixation of ankle fractures with and without the use of pneumatic tourniquets. Methods. This was a population-based cohort study using data from the Danish Fracture Database with a follow-up period of 24 months. Data were linked to the Danish National Patient Registry to ensure complete information regarding reoperations due to complications, which were divided into major and minor. The relative risk of reoperations for the tourniquet group compared with the non-tourniquet group was estimated using Cox proportional hazards modelling. Results. A total of 4,050 ankle fractures treated with open reduction and internal fixation between 15 March 2012 and 31 December 2016 were included, with 669 (16.5%) undergoing surgery with a tourniquet and 3,381 (83.5%) without a tourniquet. The overall reoperation risk was 28.2% with an adjusted relative risk of 1.46 (95% CI 0.91 to 2.32) for group comparison. The reoperation risk due to major complications was 3.1% with a tourniquet and 4.4% without a tourniquet, resulting in an adjusted relative risk of 1.45 (95% CI 0.91 to 2.32). For minor complications, there were 24.7% and 23.9% reoperations, resulting in an adjusted relative risk of 0.99 (95% CI 0.84 to 1.17). Conclusion. We found no significant difference in the reoperation rate when comparing ankle fractures treated surgically with and without the use of pneumatic tourniquets. Cite this article: Bone Joint J 2024;106-B(9):994–999


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 894 - 901
1 Jul 2022
Aebischer AS Hau R de Steiger RN Holder C Wall CJ

Aims. The aim of this study was to investigate the rate of revision for distal femoral arthroplasty (DFA) performed as a primary procedure for native knee fractures using data from the Australian Orthopaedic Association National Joint Arthroplasty Registry (AOANJRR). Methods. Data from the AOANJRR were obtained for DFA performed as primary procedures for native knee fractures from 1 September 1999 to 31 December 2020. Pathological fractures and revision for failed internal fixation were excluded. The five prostheses identified were the Global Modular Arthroplasty System, the Modular Arthroplasty System, the Modular Universal Tumour And Revision System, the Orthopaedic Salvage System, and the Segmental System. Patient demographic data (age, sex, and American Society of Anesthesiologists grade) were obtained, where available. Kaplan-Meier estimates of survival were used to determine the rate of revision, and the reasons for revision and mortality data were examined. Results. The AOANJRR identified 153 primary DFAs performed for native knee fractures in 151 patients during the study period, with 63.3% of these (n = 97) performed within the last five years. The median follow-up was 2.1 years (interquartile range 0.8 to 4.4). The patient population was 84.8% female (n = 128), with a mean age of 76.1 years (SD 11.9). The cumulative percent revision rate at three years was 10%. The most common reason for revision was loosening, followed by infection. Patient survival at one year was 87.5%, decreasing to 72.8% at three years postoperatively. Conclusion. The use of DFA to treat native knee fractures is increasing, with 63.3% of cases performed within the last five years. While long-term data are not available, the results of this study suggest that DFA may be a reasonable option for elderly patients with native knee fractures where fixation is not feasible, or for whom prolonged non-weightbearing may be detrimental. Cite this article: Bone Joint J 2022;104-B(7):894–901


Bone & Joint Open
Vol. 5, Issue 11 | Pages 1003 - 1012
8 Nov 2024
Gabr A Fontalis A Robinson J Hage W O'Leary S Spalding T Haddad FS

Aims. The aim of this study was to compare patient-reported outcomes (PROMs) following isolated anterior cruciate ligament reconstruction (ACLR), with those following ACLR and concomitant meniscal resection or repair. Methods. We reviewed prospectively collected data from the UK National Ligament Registry for patients who underwent primary ACLR between January 2013 and December 2022. Patients were categorized into five groups: isolated ACLR, ACLR with medial meniscus (MM) repair, ACLR with MM resection, ACLR with lateral meniscus (LM) repair, and ACLR with LM resection. Linear regression analysis, with isolated ACLR as the reference, was performed after adjusting for confounders. Results. From 14,895 ACLR patients, 4,400 had two- or five-year Knee injury and Osteoarthritis Outcome Scores (KOOS) available. At two years postoperatively, the MM repair group demonstrated inferior scores in KOOS pain (β = −3.63, p < 0.001), symptoms (β = − 4.88, p < 0.001), ADL (β = − 2.43, p = 0.002), sport and recreation (β = − 5.23, p < 0.001), quality of life (QoL) (β = − 5.73, p < 0.001), and International Knee Documentation Committee (β = − 4.1, p < 0.001) compared with the isolated ACLR group. The LM repair group was associated with worse KOOS sports and recreation scores at two years (β = − 4.264, p < 0.001). At five years, PROMs were comparable between the groups. At five years, PROMs were comparable between the groups. Participants undergoing ACLR surgery within 12 weeks from index injury demonstrated superior PROMs at two and five years. Conclusion. Our study showed that MM repair, and to a lesser extent LM repairs in combination with ACLR, were associated with inferior patient-reported outcome measures (PROMs) compared to isolated ACLR at two years postoperatively, while meniscal resection groups exhibited comparable outcomes. However, by five years postoperation, no significant differences in PROMs were evident. Further longer-term, cross-sectional studies are warranted to investigate the outcomes of ACLR and concomitant meniscal surgery


Bone & Joint Research
Vol. 11, Issue 10 | Pages 690 - 699
4 Oct 2022
Lenguerrand E Whitehouse MR Kunutsor SK Beswick AD Baker RP Rolfson O Reed MR Blom AW

Aims. We compared the risks of re-revision and mortality between two-stage revision surgery and single-stage revision surgery among patients with infected primary knee arthroplasty. Methods. Patients with a periprosthetic joint infection (PJI) of their primary knee arthroplasty, initially revised with a single-stage or a two-stage procedure in England and Wales between 2003 and 2014, were identified from the National Joint Registry. We used Poisson regression with restricted cubic splines to compute hazard ratios (HR) at different postoperative periods. The total number of revisions and re-revisions undergone by patients was compared between the two strategies. Results. A total of 489 primary knee arthroplasties were revised with single-stage procedure (1,390 person-years) and 2,377 with two-stage procedure (8,349 person-years). The adjusted incidence rates of all-cause re-revision and for infection were comparable between these strategies (HR overall five years, 1.15 (95% confidence interval (CI) 0.87 to 1.52), p = 0.308; HR overall five years, 0.99 (95% CI 0.70 to 1.39), p = 0.949, respectively). Patients initially managed with single-stage revision received fewer revision procedures overall than after two-stage revision (1.2 vs 2.2, p < 0.001). Mortality was lower for single-stage revision between six and 18 months postoperative (HR at six months, 0.51 (95% CI 0.25 to 1.00), p = 0.049 HR at 18 months, 0.33 (95% CI 0.12 to 0.99), p = 0.048) and comparable at other timepoints. Conclusion. The risk of re-revision was similar between single- and two-stage revision for infected primary knee arthroplasty. Single-stage group required fewer revisions overall, with lower or comparable mortality at specific postoperative periods. The single-stage revision is a safe and effective strategy to treat infected knee arthroplasties. There is potential for increased use to reduce the burden of knee PJI for patients, and for the healthcare system. Cite this article: Bone Joint Res 2022;11(10):690–699


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 864 - 871
1 Aug 2023
Tyas B Marsh M de Steiger R Lorimer M Petheram TG Inman DS Reed MR Jameson SS

Aims. Several different designs of hemiarthroplasty are used to treat intracapsular fractures of the proximal femur, with large variations in costs. No clinical benefit of modular over monoblock designs has been reported in the literature. Long-term data are lacking. The aim of this study was to report the ten-year implant survival of commonly used designs of hemiarthroplasty. Methods. Patients recorded by the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) between 1 September 1999 and 31 December 2020 who underwent hemiarthroplasty for the treatment of a hip fracture with the following implants were included: a cemented monoblock Exeter Trauma Stem (ETS), cemented Exeter V40 with a bipolar head, a monoblock Thompsons prosthesis (Cobalt/Chromium or Titanium), and an Exeter V40 with a Unitrax head. Overall and age-defined cumulative revision rates were compared over the ten years following surgery. Results. A total of 41,949 hemiarthroplasties were included. Exeter V40 with a Unitrax head was the most commonly used (n = 20,707, 49.4%). The overall rate of revision was small. A total of 28,201 patients (67.2%) were aged > 80 years. There were no significant differences in revision rates across all designs of hemiarthroplasty in patients of this age at any time. The revision rates for all designs were < 3.5%, three years postoperatively. At subsequent times the ETS and Exeter V40 with a bipolar head performed well in all age groups. The unadjusted ten-year mortality rate for the whole cohort was 82.2%. Conclusion. There was no difference in implant survival between all the designs of hemiarthroplasty in the first three years following surgery, supporting the selection of a cost-effective design of hemiarthroplasty for most patients with an intracapsular fracture of the hip, as determined by local availability and costs. Beyond this, the ETS and Exeter bipolar designs performed well in all age groups. Cite this article: Bone Joint J 2023;105-B(8):864–871


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1094 - 1098
1 Oct 2023
Jennison T Ukoumunne OC Lamb S Sharpe I Goldberg AJ

Aims. When a total ankle arthroplasty (TAA) fails, it can be converted to a fusion or a revision arthroplasty. Despite the increasing numbers of TAAs being undertaken, there is little information in the literature about the management of patients undergoing fusion following a failed TAA. The primary aim of this study was to analyze the survival of fusions following a failed TAA using a large dataset from the National Joint Registry (NJR). Methods. A data linkage study combined NJR and NHS Digital data. Failure of a TAA was defined as a fusion, revision to a further TAA, or amputation. Life tables and Kaplan-Meier graphs were used to record survival. Cox proportional hazards regression models were fitted to compare the rates of failure. Results. A total of 131 patients underwent fusion as a salvage procedure following TAA. Their mean age was 65.7 years (SD 10.6) and 73 (55.7%) were male. The mean follow-up was 47.5 months (SD 27.2). The mean time between TAA and fusion was 5.3 years (SD 2.7). Overall, 32 (24.4%) underwent reoperations other than revision and 29 (22.1%) failed. Of these 24 (18.3%) underwent revision of the fusion and five (3.8%) had a below-knee amputation. No patients underwent conversion to a further TAA. Failure usually occurred in the first three postoperative years with one-year survival of fusion being 96.0% (95% confidence interval (CI) 90.7 to 98.3) and three-year survival in 69 patients being 77.5% (95% CI 68.3 to 84.4). Conclusion. Salvage fusion after a failed TAA shows moderate rates of failure and reoperations. Nearly 25% of patients required revision within three years. This study is an extension of studies using the same methodology reporting the failure rates and risk factors for failure, which have recently been published, and also one reporting the outcome of revision TAA for a failed primary TAA, using the same methodology, which will shortly be published. Cite this article: Bone Joint J 2023;105-B(10):1094–1098


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1060 - 1069
1 Oct 2023
Holleyman RJ Jameson SS Reed M Meek RMD Khanduja V Hamer A Judge A Board T

Aims. This study describes the variation in the annual volumes of revision hip arthroplasty (RHA) undertaken by consultant surgeons nationally, and the rate of accrual of RHA and corresponding primary hip arthroplasty (PHA) volume for new consultants entering practice. Methods. National Joint Registry (NJR) data for England, Wales, Northern Ireland, and the Isle of Man were received for 84,816 RHAs and 818,979 PHAs recorded between April 2011 and December 2019. RHA data comprised all revision procedures, including first-time revisions of PHA and any subsequent re-revisions recorded in public and private healthcare organizations. Annual procedure volumes undertaken by the responsible consultant surgeon in the 12 months prior to every index procedure were determined. We identified a cohort of ‘new’ HA consultants who commenced practice from 2012 and describe their rate of accrual of PHA and RHA experience. Results. The median annual consultant RHA volume, averaged across all cases, was 21 (interquartile range (IQR) 11 to 34; range 0 to 181). Of 1,695 consultants submitting RHA cases within the study period, the top 20% of surgeons by annual volume performed 74.2% of total RHA case volume. More than half of all consultants who had ever undertaken a RHA maintained an annual volume of just one or fewer RHA, however, collectively contributed less than 3% of the total RHA case volume. Consultant PHA and RHA volumes were positively correlated. Lower-volume surgeons were more likely to undertake RHA for urgent indications (such as infection) as a proportion of their practice, and to do so on weekends and public holidays. Conclusion. The majority of RHAs were undertaken by higher-volume surgeons. There was considerable variation in RHA volumes by indication, day of the week, and between consultants nationally. The rate of accrual of RHA experience by new consultants is low, and has important implications for establishing an experienced RHA consultant workforce. Cite this article: Bone Joint J 2023;105-B(10):1060–1069


The Bone & Joint Journal
Vol. 105-B, Issue 11 | Pages 1184 - 1188
1 Nov 2023
Jennison T Ukoumunne OC Lamb S Goldberg AJ Sharpe I

Aims. The number of revision total ankle arthroplasties (TAAs) which are undertaken is increasing. Few studies have reported the survival after this procedure. The primary aim of this study was to analyze the survival of revision ankle arthroplasties using large datasets. Secondary aims were to summarize the demographics of the patients, the indications for revision TAA, further operations, and predictors of survival. Methods. The study combined data from the National Joint Registry and NHS Digital to report the survival of revision TAA. We have previously reported the failure rates and risk factors for failure after TAA, and the outcome of fusion after a failed TAA, using the same methodology. Survival was assessed using life tables and Kaplan Meier graphs. Cox proportional hazards regression models were fitted to compare failure rates. Results. A total of 228 patients underwent revision TAA. The mean follow-up was 2.6 years (SD 2.0). The mean time between the initial procedure and revision was 2.3 years (SD 1.8). The most commonly used implant was the Inbone which was used in 81 patients. A total of 29 (12.7%) failed; nine (3.9%) patients underwent a further revision, 19 (8.3%) underwent a fusion, and one (0.4%) had an amputation. The rate of survival was 95.4% (95% confidence interval (CI) 91.6 to 97.5) at one year, 87.7% (95% CI 81.9 to 91.7; n = 124) at three years and 77.5% (95% CI 66.9 to 85.0; n = 57) at five years. Revision-specific implants had a better survival than when primary implants were used at revision. A total of 50 patients (21.9%) had further surgery; 19 (8.3%) underwent reoperation in the first 12 months. Cox regression models were prepared. In crude analysis the only significant risk factors for failure were the use of cement (hazard ratio (HR) 3.02 (95% CI 1.13 to 8.09)) and the time since the primary procedure (HR 0.67 (95% CI 0.47 to 0.97)). No risk factors for failure were identified in multivariable Cox regression modelling. Conclusion. Revision TAAs have good medium term survival and low rates of further surgery. New modular revision implants appear to have improved the survival compared with the use of traditional primary implants at revision. Cite this article: Bone Joint J 2023;105-B(11):1184–1188


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 47 - 55
1 Jan 2023
Clement ND Avery P Mason J Baker PN Deehan DJ

Aims. The aim of this study was to identify variables associated with time to revision, demographic details associated with revision indication, and type of prosthesis employed, and to describe the survival of hinge knee arthroplasty (HKA) when used for first-time knee revision surgery and factors that were associated with re-revision. Methods. Patient demographic details, BMI, American Society of Anesthesiologists (ASA) grade, indication for revision, surgical approach, surgeon grade, implant type (fixed and rotating), time of revision from primary implantation, and re-revision if undertaken were obtained from the National Joint Registry data for England, Wales, Northern Ireland, and the Isle of Man over an 18-year period (2003 to 2021). Results. There were 3,855 patient episodes analyzed with a median age of 73 years (interquartile range (IQR) 66 to 80), and the majority were female (n = 2,480, 64.3%). The median time to revision from primary knee arthroplasty was 1,219 days (IQR 579 to 2,422). Younger age (p < 0.001), decreasing ASA grade (p < 0.001), and indications for revision of sepsis (p < 0.001), unexplained pain (p < 0.001), non-polyethylene wear (p < 0.001), and malalignment (p < 0.001) were all associated with an earlier time to revision from primary implantation. The median follow-up was 4.56 years (range 0.00 to 17.52), during which there were 410 re-revisions. The overall unadjusted probability of re-revision for all revision HKAs at one, five, and ten years after surgery were 2.7% (95% confidence interval (CI) 2.2 to 3.3), 10.7% (95% CI 9.6 to 11.9), and 16.2% (95% CI 14.5 to 17.9), respectively. Male sex (p < 0.001), younger age (p < 0.001), revision for septic indications (p < 0.001) or implant fracture (p = 0.010), a fixed hinge (p < 0.001), or surgery performed by a non-consultant grade (p = 0.023) were independently associated with an increased risk of re-revision. Conclusion. There were several factors associated with time to first revision. The re-revision rate was 16.2% at ten years; however, the risk factors associated with an increased risk of re-revision could be used to counsel patients regarding their outcome. Cite this article: Bone Joint J 2023;105-B(1):47–55


The Bone & Joint Journal
Vol. 104-B, Issue 9 | Pages 1052 - 1059
1 Sep 2022
Penfold CM Judge A Sayers A Whitehouse MR Wilkinson JM Blom AW

Aims. Our main aim was to describe the trend in the comorbidities of patients undergoing elective total hip arthroplasties (THAs) and knee arthroplasties (KAs) between 1 January 2005 and 31 December 2018 in England. Methods. We combined data from the National Joint Registry (NJR) on primary elective hip and knee arthroplasties performed between 2005 and 2018 with pre-existing conditions recorded at the time of their primary operation from Hospital Episodes Statistics. We described the temporal trend in the number of comorbidities identified using the Charlson Comorbidity Index, and how this varied by age, sex, American Society of Anesthesiologists (ASA) grade, index of multiple deprivation, and type of KA. Results. We included 696,504 and 833,745 elective primary THAs and KAs respectively, performed for any indication. Between 2005 and 2018, the proportion of elective THA and KA patients with one or more comorbidity at the time of their operation increased substantially (THA: 20% to 38%, KA: 22% to 41%). This was driven by increases in four conditions: chronic obstructive pulmonary disease (COPD) (2018: ~17%), diabetes without complications (2018: THA 10%, KA 14%), myocardial infarction (2018: 4%), and renal disease (2018: ~8%). Notably, renal disease prevalence increased from < 1% in 2005 to ~8% in 2018. Conclusion. Between 2005 and 2018 there were significant changes in the number of comorbidities recorded in patients having elective primary THAs and KAs. Renal disease is now one of the most prevalent comorbidities in this patient population. Future research should explore whether this comorbidity trend has increased the burden on other medical specialities to optimize these patients before surgery and to provide additional postoperative care. Cite this article: Bone Joint J 2022;104-B(9):1052–1059


The Bone & Joint Journal
Vol. 104-B, Issue 9 | Pages 1060 - 1066
1 Sep 2022
Jin X Gallego Luxan B Hanly M Pratt NL Harris I de Steiger R Graves SE Jorm L

Aims. The aim of this study was to estimate the 90-day periprosthetic joint infection (PJI) rates following total knee arthroplasty (TKA) and total hip arthroplasty (THA) for osteoarthritis (OA). Methods. This was a data linkage study using the New South Wales (NSW) Admitted Patient Data Collection (APDC) and the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR), which collect data from all public and private hospitals in NSW, Australia. Patients who underwent a TKA or THA for OA between 1 January 2002 and 31 December 2017 were included. The main outcome measures were 90-day incidence rates of hospital readmission for: revision arthroplasty for PJI as recorded in the AOANJRR; conservative definition of PJI, defined by T84.5, the PJI diagnosis code in the APDC; and extended definition of PJI, defined by the presence of either T84.5, or combinations of diagnosis and procedure code groups derived from recursive binary partitioning in the APDC. Results. The mean 90-day revision rate for infection was 0.1% (0.1% to 0.2%) for TKA and 0.3% (0.1% to 0.5%) for THA. The mean 90-day PJI rates defined by T84.5 were 1.3% (1.1% to 1.7%) for TKA and 1.1% (0.8% to 1.3%) for THA. The mean 90-day PJI rates using the extended definition were 1.9% (1.5% to 2.2%) and 1.5% (1.3% to 1.7%) following TKA and THA, respectively. Conclusion. When reporting the revision arthroplasty for infection, the AOANJRR substantially underestimates the rate of PJI at 90 days. Using combinations of infection codes and PJI-related surgical procedure codes in linked hospital administrative databases could be an alternative way to monitor PJI rates. Cite this article: Bone Joint J 2022;104-B(9):1060–1066


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 895 - 904
1 Aug 2023
Smith TO Dainty J Loveday DT Toms A Goldberg AJ Watts L Pennington MW Dawson J van der Meulen J MacGregor AJ

Aims. The aim of this study was to capture 12-month outcomes from a representative multicentre cohort of patients undergoing total ankle arthroplasty (TAA), describe the pattern of patient-reported outcome measures (PROMs) at 12 months, and identify predictors of these outcome measures. Methods. Patients listed for a primary TAA at 19 NHS hospitals between February 2016 and October 2017 were eligible. PROMs data were collected preoperatively and at six and 12 months including: Manchester-Oxford Foot and Ankle Questionnaire (MOXFQ (foot and ankle)) and the EuroQol five-dimension five-level questionnaire (EQ-5D-5L). Radiological pre- and postoperative data included Kellgren-Lawrence score and implant position measurement. This was supplemented by data from the National Joint Registry through record linkage to determine: American Society of Anesthesiologists (ASA) grade at index procedure; indication for surgery, index ankle previous fracture; tibial hind foot alignment; additional surgery at the time of TAA; and implant type. Multivariate regression models assessed outcomes, and the relationship between MOXFQ and EQ-5D-5L outcomes, with patient characteristics. Results. Data from 238 patients were analyzed. There were significant improvements in MOXFQ and EQ-5D-5L among people who underwent TAA at six- and 12-month assessments compared with preoperative scores (p < 0.001). Most improvement occurred between preoperative and six months, with little further improvement at 12 months. A greater improvement in MOXFQ outcome postoperatively was associated with older age and more advanced radiological signs of ankle osteoarthritis at baseline. Conclusion. TAA significantly benefits patients with end-stage ankle disease. The lack of substantial further overall change between six and 12 months suggests that capturing PROMs at six months is sufficient to assess the success of the procedure. Older patients and those with advanced radiological disease had the greater gains. These outcome predictors can be used to counsel younger patients and those with earlier ankle disease on the expectations of TAA. Cite this article: Bone Joint J 2023;105-B(8):895–904


The Bone & Joint Journal
Vol. 101-B, Issue 6 | Pages 702 - 707
1 Jun 2019
Moeini S Rasmussen JV Salomonsson B Domeij-Arverud E Fenstad AM Hole R Jensen SL Brorson S

Aims. The aim of this study was to use national registry database information to estimate cumulative rates and relative risk of revision due to infection after reverse shoulder arthroplasty. Patients and Methods. We included 17 730 primary shoulder arthroplasties recorded between 2004 and 2013 in The Nordic Arthroplasty Register Association (NARA) data set. With the Kaplan–Meier method, we illustrated the ten-year cumulative rates of revision due to infection and with the Cox regression model, we reported the hazard ratios as a measure of the relative risk of revision due to infection. Results. In all, 188 revisions were reported due to infection during a mean follow-up of three years and nine months. The ten-year cumulative rate of revision due to infection was 1.4% overall, but 3.1% for reverse shoulder arthroplasties and 8.0% for reverse shoulder arthroplasties in men. Reverse shoulder arthroplasties were associated with an increased risk of revision due to infection also when adjusted for sex, age, primary diagnosis, and year of surgery (relative risk 2.41 (95% confidence interval 1.26 to 5.59); p = 0.001). Conclusion. The overall incidence of revision due to infection was low. The increased risk in reverse shoulder arthroplasty must be borne in mind, especially when offering it to men. Cite this article: Bone Joint J 2019;101-B:702–707


Bone & Joint Open
Vol. 3, Issue 8 | Pages 656 - 665
23 Aug 2022
Tran T McEwen P Peng Y Trivett A Steele R Donnelly W Clark G

Aims. The mid-term results of kinematic alignment (KA) for total knee arthroplasty (TKA) using image derived instrumentation (IDI) have not been reported in detail, and questions remain regarding ligamentous stability and revisions. This paper aims to address the following: 1) what is the distribution of alignment of KA TKAs using IDI; 2) is a TKA alignment category associated with increased risk of failure or poor patient outcomes; 3) does extending limb alignment lead to changes in soft-tissue laxity; and 4) what is the five-year survivorship and outcomes of KA TKA using IDI?. Methods. A prospective, multicentre, trial enrolled 100 patients undergoing KA TKA using IDI, with follow-up to five years. Alignment measures were conducted pre- and postoperatively to assess constitutional alignment and final implant position. Patient-reported outcome measures (PROMs) of pain and function were also included. The Australian Orthopaedic Association National Joint Arthroplasty Registry was used to assess survivorship. Results. The postoperative HKA distribution varied from 9° varus to 11° valgus. All PROMs showed statistical improvements at one year (p < 0.001), with further improvements at five years for Knee Osteoarthritis Outcome Score symptoms (p = 0.041) and Forgotten Joint Score (p = 0.011). Correlation analysis showed no difference (p = 0.610) between the hip-knee-ankle and joint line congruence angle at one and five years. Sub-group analysis showed no difference in PROMs for patients placed within 3° of neutral compared to those placed > 3°. There were no revisions for tibial loosening; however, there were reports of a higher incidence of poor patella tracking and patellofemoral stiffness. Conclusion. PROMs were not impacted by postoperative alignment category. Ligamentous stability was maintained at five years with joint line obliquity. There were no revisions for tibial loosening despite a significant portion of tibiae placed in varus; however, KA executed with IDI resulted in a higher than anticipated rate of patella complications. Cite this article: Bone Jt Open 2022;3(8):656–665


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 820 - 825
1 Jul 2022
Dhawan R Baré JV Shimmin A

Aims. Adverse spinal motion or balance (spine mobility) and adverse pelvic mobility, in combination, are often referred to as adverse spinopelvic mobility (SPM). A stiff lumbar spine, large posterior standing pelvic tilt, and severe sagittal spinal deformity have been identified as risk factors for increased hip instability. Adverse SPM can create functional malposition of the acetabular components and hence is an instability risk. Adverse pelvic mobility is often, but not always, associated with abnormal spinal motion parameters. Dislocation rates for dual-mobility articulations (DMAs) have been reported to be between 0% and 1.1%. The aim of this study was to determine the early survivorship from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) of patients with adverse SPM who received a DMA. Methods. A multicentre study was performed using data from 227 patients undergoing primary total hip arthroplasty (THA), enrolled consecutively. All the patients who had one or more adverse spine or pelvic mobility parameter had a DMA inserted at the time of their surgery. The mean age was 76 years (22 to 93) and 63% were female (n = 145). At a mean of 14 months (5 to 31) postoperatively, the AOANJRR was analyzed for follow-up information. Reasons for revision and types of revision were identified. Results. The AOANJRR reported two revisions: one due to infection, and the second due to femoral component loosening. No revisions for dislocation were reported. One patient died with the prosthesis in situ. Kaplan-Meier survival rate was 99.1% (95% confidence interval 98.3 to 100) at 14 months (number at risk 104). Conclusion. In our cohort of patients undergoing primary THA with one or more factor associated with adverse SPM, DM bearings conferred stability at two years’ follow-up. Cite this article: Bone Joint J 2022;104-B(7):820–825


Bone & Joint Open
Vol. 4, Issue 11 | Pages 853 - 858
10 Nov 2023
Subbiah Ponniah H Logishetty K Edwards TC Singer GC

Aims. Metal-on-metal hip resurfacing (MoM-HR) has seen decreased usage due to safety and longevity concerns. Joint registries have highlighted the risks in females, smaller hips, and hip dysplasia. This study aimed to identify if reported risk factors are linked to revision in a long-term follow-up of MoM-HR performed by a non-designer surgeon. Methods. A retrospective review of consecutive MoM hip arthroplasties (MoM-HRAs) using Birmingham Hip Resurfacing was conducted. Data on procedure side, indication, implant sizes and orientation, highest blood cobalt and chromium ion concentrations, and all-cause revision were collected from local and UK National Joint Registry records. Results. A total of 243 hips (205 patients (163 male, 80 female; mean age at surgery 55.3 years (range 25.7 to 75.3)) with MoM-HRA performed between April 2003 and October 2020 were included. Mean follow-up was 11.2 years (range 0.3 to 17.8). Osteoarthritis was the most common indication (93.8%), and 13 hips (5.3%; 7M:6F) showed dysplasia (lateral centre-edge angle < 25°). Acetabular cups were implanted at a median of 45.4° abduction (interquartile range 41.9° - 48.3°) and stems neutral or valgus to the native neck-shaft angle. In all, 11 hips (4.5%; one male, ten females) in ten patients underwent revision surgery at a mean of 7.4 years (range 2.8 to 14.2), giving a cumulative survival rate of 94.8% (95% confidence interval (CI) 91.6% to 98.0%) at ten years, and 93.4% (95% CI 89.3% to 97.6%) at 17 years. For aseptic revision, male survivorship was 100% at 17 years, and 89.6% (95% CI 83.1% to 96.7%) at ten and 17 years for females. Increased metal ion levels were implicated in 50% of female revisions, with the remaining being revised for unexplained pain or avascular necrosis. Conclusion. The Birmingham MoM-HR showed 100% survivorship in males, exceeding the National Institute for Health and Care Excellence ‘5% at ten years’ threshold. Female sex and small component sizes are independent risk factors. Dysplasia alone is not a contraindication to resurfacing. Cite this article: Bone Jt Open 2023;4(11):853–858


The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 729 - 735
1 Jun 2022
Craxford S Marson BA Nightingale J Forward DP Taylor A Ollivere B

Aims. The last decade has seen a marked increase in surgical rib fracture fixation (SRF). The evidence to support this comes largely from retrospective cohorts, and adjusting for the effect of other injuries sustained at the same time is challenging. This study aims to assess the impact of SRF after blunt chest trauma using national prospective registry data, while controlling for other comorbidities and injuries. Methods. A ten-year extract from the Trauma Audit and Research Network formed the study sample. Patients who underwent SRF were compared with those who received supportive care alone. The analysis was performed first for the entire eligible cohort, and then for patients with a serious (thoracic Abbreviated Injury Scale (AIS) ≥ 3) or minor (thoracic AIS < 3) chest injury without significant polytrauma. Multivariable logistic regression was performed to identify predictors of mortality. Kaplan-Meier estimators and multivariable Cox regression were performed to adjust for the effects of concomitant injuries and other comorbidities. Outcomes assessed were 30-day mortality, length of stay (LoS), and need for tracheostomy. Results. A total of 86,838 cases were analyzed. The rate of SRF was 1.2%. SRF significantly reduced risk of mortality (odds ratio (OR) 0.27 (95 confidence interval (CI) 0.128 to 0.273); p < 0.001) and need for tracheostomy (OR 0.22 (95% CI 0.191 to 0.319); p < 0.001) after adjustment for other covariables across the whole cohort. SRF remained protective in patients with a serious chest injury (hazard ratio (HR) 0.24 (95% CI 0.13 to 0.45); p < 0.001). The benefit in more minor chest injury was less clear. Mean LoS for patients who survived was longer in the SRF group (24.29 days (SD 26.54) vs 16.60 days (SD 26.35); p < 0.001). Conclusion. SRF reduces mortality after significant chest trauma associated with both major and minor polytrauma. The rate of fixation in the UK is low and potentially underused as a treatment for severe chest wall injury. Cite this article: Bone Joint J 2022;104-B(6):729–735


The Bone & Joint Journal
Vol. 104-B, Issue 3 | Pages 359 - 367
1 Mar 2022
Deere K Matharu GS Ben-Shlomo Y Wilkinson JM Blom AW Sayers A Whitehouse MR

Aims. A recent report from France suggested an association between the use of cobalt-chrome (CoCr) femoral heads in total hip arthroplasties (THAs) and an increased risk of dilated cardiomyopathy and heart failure. CoCr is a commonly used material in orthopaedic implants. If the reported association is causal, the consequences would be significant given the millions of joint arthroplasties and other orthopaedic procedures in which CoCr is used annually. We examined whether CoCr-containing THAs were associated with an increased risk of all-cause mortality, heart outcomes, cancer, and neurodegenerative disorders in a large national database. Methods. Data from the National Joint Registry was linked to NHS English hospital inpatient episodes for 374,359 primary THAs with up to 14.5 years' follow-up. We excluded any patients with bilateral THAs, knee arthroplasties, indications other than osteoarthritis, aged under 55 years, and diagnosis of one or more outcome of interest before THA. Implants were grouped as either containing CoCr or not containing CoCr. The association between implant construct and the risk of all-cause mortality and incident heart failure, cancer, and neurodegenerative disorders was examined. Results. There were 158,677 individuals (42.4%) with an implant containing CoCr. There were 47,963 deaths, 27,332 heart outcomes, 35,720 cancers, and 22,025 neurodegenerative disorders. There was no evidence of an association between patients with CoCr implants and higher rates of any of the outcomes. Conclusion. CoCr-containing THAs did not have an increased risk of all-cause mortality, or clinically meaningful heart outcomes, cancer, or neurodegenerative disorders into the second decade post-implantation. Our findings will help reassure clinicians and the increasing number of patients receiving primary THA worldwide that the use of CoCr-containing implants is not associated with significant adverse systemic effects. Cite this article: Bone Joint J 2022;104-B(3):359–367


The Bone & Joint Journal
Vol. 102-B, Issue 3 | Pages 319 - 328
1 Mar 2020
St Mart J de Steiger RN Cuthbert A Donnelly W

Aim. There has been a significant reduction in unicompartmental knee arthroplasty (UKA) procedures recorded in Australia. This follows several national joint registry studies documenting high UKA revision rates when compared to total knee arthroplasty (TKA). With the recent introduction of robotically assisted UKA procedures, it is hoped that outcomes improve. This study examines the cumulative revision rate of UKA procedures implanted with a newly introduced robotic system and compares the results to one of the best performing non-robotically assisted UKA prostheses, as well as all other non-robotically assisted UKA procedures. Methods. Data from the Australian Orthopaedic Association National Joint Arthroplasty Registry (AOANJRR) for all UKA procedures performed for osteoarthritis (OA) between 2015 and 2018 were analyzed. Procedures using the Restoris MCK UKA prosthesis implanted using the Mako Robotic-Arm Assisted System were compared to non-robotically assisted Zimmer Unicompartmental High Flex Knee System (ZUK) UKA, a commonly used UKA with previously reported good outcomes and to all other non-robotically assisted UKA procedures using Cox proportional hazard ratios (HRs) and Kaplan-Meier estimates of survivorship. Results. There was no difference in the rate of revision when the Mako-assisted Restoris UKA was compared to the ZUK UKA (zero to nine months: HR 1.14 (95% CI 0.71 to 1.83; p = 0.596) vs nine months and over: HR 0.66 (95% CI 0.42 to 1.02; p = 0.058)). The Mako-assisted Restoris had a significantly lower overall revision rate compared to the other types of non-robotically assisted procedures (HR 0.58 (95% confidence interval (CI) 0.42 to 0.79); p < 0.001) at three years. Revision for aseptic loosening was lower for the Mako-assisted Restoris compared to all other non-robotically assisted UKA (entire period: HR 0.34 (95% CI 0.17 to 0.65); p = 0.001), but not the ZUK prosthesis. However, revision for infection was significantly higher for the Mako-assisted Restoris compared to the two comparator groups (ZUK: entire period: HR 2.91 (95% CI 1.22 to 6.98; p = 0.016); other non-robotically assisted UKA: zero to three months: HR 5.57 (95% CI 2.17 to 14.31; p < 0.001)). Conclusion. This study reports comparable short-term survivorship for the Mako robotically assisted UKA compared to the ZUK UKA and improved survivorship compared to all other non-robotic UKA. These results justify the continued use and investigation of this procedure. However, the higher rate of early revision for infection for robotically assisted UKA requires further investigation. Cite this article: Bone Joint J 2020;102-B(3):319–328


The Bone & Joint Journal
Vol. 99-B, Issue 1 | Pages 12 - 15
1 Jan 2017
Murray DW Liddle AD Judge A Pandit H

We recently published a paper comparing the incidence of adverse outcomes after unicompartmental and total knee arthroplasty (UKA and TKA). The conclusion of this study, which was in favour of UKA, was dismissed as “biased” in a review in Bone & Joint 360. Although this study is one of the least biased comparisons of UKA and TKA, this episode highlights the biases that exist both for and against UKA. In this review, we explore the different types of bias, particularly selection, reporting and measurement. We conclude that comparisons between UKA and TKA are open to bias. These biases can be so marked, particularly in comparisons based just on national registry data, that the conclusions can be misleading. For a fair comparison, data from randomised studies or well-matched, prospective observational cohort studies, which include registry data, are required, and multiple outcome measures should be used. The data of this type that already exist suggest that if UKA is used appropriately, compared with TKA, its advantages outweigh its disadvantages. Cite this article: Bone Joint J 2017;99-B:12–15


Aims. The aim of this study was to evaluate medium-term outcomes and complications of the S-ROM NOILES Rotating Hinge Knee System (DePuy, USA) in revision total knee arthroplasty (rTKA) at a tertiary unit. Methods. A retrospective consecutive study of all patients who underwent a rTKA using this implant from January 2005 to December 2018. Outcome measures included reoperations, revision for any cause, complications, and survivorship. Patients and implant survivorship data were identified through both local hospital electronic databases and linked data from the National Joint Registry/NHS Personal Demographic Service. Kaplan-Meier survival analysis was used at ten years. Results. A total of 89 consecutive patients (89 knees) were included with 47 females (52.8%) and a median age of 74 years (interquartile range 66 to 79). The main indications were aseptic loosening with instability (39.4%; n = 35) and infection (37.1%; n = 33) with the majority of patients managed through two-stage approach. The mean follow-up was 7.4 years (2 to 16). The overall rate of reoperation, for any cause, was 10.1% (n = 9) with a rate of implant revision of 6.7% (n = 6). Only two cases required surgery for patellofemoral complications. Kaplan-Meier implant-survivorship analysis was 93.3% at ten years, using revision for any cause as an endpoint. Conclusion. This implant achieved high ten-year survivorship with a low complication rate, particularly patellofemoral complications. These can be avoided by ensuring central patella tracking and appropriate tension of the patellofemoral joint in this posterior hinge design. Cite this article: Bone Jt Open 2022;3(3):205–210


The Bone & Joint Journal
Vol. 104-B, Issue 3 | Pages 341 - 351
1 Mar 2022
Fowler TJ Aquilina AL Reed MR Blom AW Sayers A Whitehouse MR

Aims. Total hip arthroplasties (THAs) are performed by surgeons at various stages in training with varying levels of supervision, but we do not know if this is safe practice with comparable outcomes to consultant-performed THA. Our aim was to examine the association between surgeon grade, the senior supervision of trainees, and the risk of revision following THA. Methods. We performed an observational study using National Joint Registry (NJR) data. We included adult patients who underwent primary THA for osteoarthritis, recorded in the NJR between 2003 and 2016. Exposures were operating surgeon grade (consultant or trainee) and whether or not trainees were directly supervised by a scrubbed consultant. Outcomes were all-cause revision and the indication for revision up to ten years. We used methods of survival analysis, adjusted for patient, operation, and healthcare setting factors. Results. We included 603,474 THAs, of which 58,137 (9.6%) procedures were performed by a trainee. There was no association between surgeon grade and all-cause revision up to ten years (crude hazard ratio (HR) 1.00 (95% confidence interval (CI) 0.94 to 1.07); p = 0.966), a finding which persisted with adjusted analysis. Fully adjusted analysis demonstrated an association between trainees operating without scrubbed consultant supervision and an increased risk of all-cause revision (HR 1.10 (95% CI 1.00 to 1.21); p = 0.045). There was an association between trainee-performed THA and revision for instability (HR 1.14 (95% CI 1.01 to 1.30); p = 0.039). However, this was not observed in adjusted models, or when trainees were supervised by a scrubbed consultant. Conclusion. Within the current training system in England and Wales, appropriately supervised trainees achieve comparable THA survival to consultants. Trainees who are supervised by a scrubbed consultant achieve superior outcomes compared to trainees who are not supervised by a scrubbed consultant, particularly in terms of revision for instability. Cite this article: Bone Joint J 2022;104-B(3):341–351


The Bone & Joint Journal
Vol. 103-B, Issue 12 | Pages 1774 - 1782
1 Dec 2021
Divecha HM O'Neill TW Lunt M Board TN

Aims. The aim of this study was to determine if uncemented acetabular polyethylene (PE) liner geometry, and lip size, influenced the risk of revision for instability or loosening. Methods. A total of 202,511 primary total hip arthroplasties (THAs) with uncemented acetabular components were identified from the National Joint Registry (NJR) dataset between 2003 and 2017. The effect of liner geometry on the risk of revision for instability or loosening was investigated using competing risk regression analyses adjusting for age, sex, American Society of Anesthesiologists grade, indication, side, institution type, surgeon grade, surgical approach, head size, and polyethylene crosslinking. Stratified analyses by surgical approach were performed, including pairwise comparisons of liner geometries. Results. The distribution of liner geometries were neutral (39.4%; 79,822), 10° (34.5%; 69,894), 15° (21.6%; 43,722), offset reorientating (2.8%; 5705), offset neutral (0.9%; 1,767), and 20° (0.8%; 1,601). There were 690 (0.34%) revisions for instability. Compared to neutral liners, the adjusted subhazard ratios of revision for instability were: 10°, 0.64 (p < 0.001); 15°, 0.48 (p < 0.001); and offset reorientating, 1.6 (p = 0.010). No association was found with other geometries. 10° and 15° liners had a time-dependent lower risk of revision for instability within the first 1.2 years. In posterior approaches, 10° and 15° liners had a lower risk of revision for instability, with no significant difference between them. The protective effect of lipped over neutral liners was not observed in laterally approached THAs. There were 604 (0.3%) revisions for loosening, but no association between liner geometry and revision for loosening was found. Conclusion. This registry-based study confirms a lower risk of revision for instability in posterior approach THAs with 10° or 15° lipped liners compared to neutral liners, but no significant difference between these lip sizes. A higher revision risk is seen with offset reorientating liners. The benefit of lipped geometries against revision for instability was not seen in laterally approached THAs. Liner geometry does not seem to influence the risk of revision for loosening. Cite this article: Bone Joint J 2021;103-B(12):1774–1782