Advertisement for orthosearch.org.uk
Results 1 - 50 of 96
Results per page:
Bone & Joint Open
Vol. 4, Issue 1 | Pages 19 - 26
13 Jan 2023
Nishida K Nasu Y Hashizume K Okita S Nakahara R Saito T Ozaki T Inoue H

Aims. There are concerns regarding complications and longevity of total elbow arthroplasty (TEA) in young patients, and the few previous publications are mainly limited to reports on linked elbow devices. We investigated the clinical outcome of unlinked TEA for patients aged less than 50 years with rheumatoid arthritis (RA). Methods. We retrospectively reviewed the records of 26 elbows of 21 patients with RA who were aged less than 50 years who underwent primary TEA with an unlinked elbow prosthesis. The mean patient age was 46 years (35 to 49), and the mean follow-up period was 13.6 years (6 to 27). Outcome measures included pain, range of motion, Mayo Elbow Performance Score (MEPS), radiological evaluation for radiolucent line and loosening, complications, and revision surgery with or without implant removal. Results. The mean MEPS significantly improved from 47 (15 to 70) points preoperatively to 95 (70 to 100) points at final follow-up (p < 0.001). Complications were noted in six elbows (23%) in six patients, and of these, four with an ulnar neuropathy and one elbow with postoperative traumatic fracture required additional surgeries. There was no revision with implant removal, and there was no radiological evidence of loosening around the components. With any revision surgery as the endpoint, the survival rates up to 25 years were 78.1% (95% confidence interval 52.8 to 90.6) as determined by Kaplan-Meier analysis. Conclusion. The clinical outcome of primary unlinked TEA for young patients with RA was satisfactory and comparable with that for elderly patients. A favourable survival rate without implant removal might support the use of unlinked devices for young patients with this disease entity, with a caution of a relatively high complication rate regarding ulnar neuropathy. Level of Evidence: Therapeutic Level IV. Cite this article: Bone Jt Open 2023;4(1):19–26


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 905 - 911
1 Aug 2023
Giannicola G Amura A Sessa P Prigent S Cinotti G

Aims. The aim of this study was to analyze how proximal radial neck resorption (PRNR) starts and progresses radiologically in two types of press-fit radial head arthroplasties (RHAs), and to investigate its clinical relevance. Methods. A total of 97 patients with RHA were analyzed: 56 received a bipolar RHA (Group 1) while 41 received an anatomical implant (Group 2). Radiographs were performed postoperatively and after three, six, nine, and 12 weeks, six, nine, 12, 18, and 24 months, and annually thereafter. PRNR was measured in all radiographs in the four radial neck quadrants. The Mayo Elbow Performance Score (MEPS), the abbreviated version of the Disabilities of the Arm, Shoulder, and Hand questionnaire (QuickDASH), and the patient-assessed American Shoulder and Elbow Surgeons score - Elbow (pASES-E) were used for the clinical assessment. Radiological signs of implant loosening were investigated. Results. The mean follow-up was six years (2 to 14). PRNR started after a mean of 7.5 weeks (SD 2.1) and progressed significantly during the first two years, by the end of which the bone resorption stabilized. PRNR was detected in 81% (n = 45) of patients in Group 1 and 88% (n = 36) in Group 2. The final mean PRNR was 3.0 mm (SD 2.3) in Group 1 and 3.7 mm (SD 2.5) in Group 2. The mean MEPS, QuickDASH, and pASES-E were 95.9 (SD 11.5), 4.4 (SD 9.2), and 94.8 (SD 10.9) in Group 1 and 92.2 (SD 16.2), 9.9 (SD 21.5), and 90.8 (SD 15) in Group 2, respectively. No significant differences were observed between groups in the clinical and radiological outcomes. No correlations were found between PRNR and the clinical results. Conclusion. PRNR after press-fit RHA is a common radiological finding that develops in the first 24 months before stabilizing definitively. PRNR does not affect the clinical results or implant survival in the mid term. Cite this article: Bone Joint J 2023;105-B(8):905–911


The Bone & Joint Journal
Vol. 104-B, Issue 5 | Pages 559 - 566
1 May 2022
Burden EG Batten T Smith C Evans JP

Aims. Arthroplasty is being increasingly used for the management of distal humeral fractures (DHFs) in elderly patients. Arthroplasty options include total elbow arthroplasty (TEA) and hemiarthroplasty (HA); both have unique complications and there is not yet a consensus on which implant is superior. This systematic review asked: in patients aged over 65 years with unreconstructable DHFs, what differences are there in outcomes, as measured by patient-reported outcome measures (PROMs), range of motion (ROM), and complications, between distal humeral HA and TEA?. Methods. A systematic review of the literature was performed via a search of MEDLINE and Embase. Two reviewers extracted data on PROMs, ROM, and complications. PROMs and ROM results were reported descriptively and a meta-analysis of complications was conducted. Quality of methodology was assessed using Wylde’s non-summative four-point system. The study was registered with PROSPERO (CRD42021228329). Results. A total of 29 studies met the inclusion and exclusion criteria. The mean Disabilities of the Arm, Shoulder and Hand questionnaire (DASH) score was 19.6 (SD 7.5) for HA and 38 (SD 11.9) for TEA and the mean abbreviated version of DASH was 17.2 (SD 13.2) for HA and 24.9 (SD 4.8) for TEA. The Mayo Elbow Performance Score was the most commonly reported PROM across included studies, with a mean of 87 (SD 5.3) in HA and 88.3 (SD 5) in TEA. High complication rates were seen in both HA (22% (95% confidence interval (CI) 5 to 44)) and TEA (21% (95% CI 13 to 30), but no statistically significant difference identified. Conclusion. This systematic review has indicated PROMs and ROM mostly favouring HA, but with a similarly high complication rate in the two procedures. However, due to the small sample size and heterogeneity between studies, strength of evidence for these findings is low. We propose further research in the form of a national randomized controlled trial. Cite this article: Bone Joint J 2022;104-B(5):559–566


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1158 - 1164
1 Oct 2024
Jakobi T Krieg I Gramlich Y Sauter M Schnetz M Hoffmann R Klug A

Aims. The aim of this study was to evaluate the outcome of complex radial head fractures at mid-term follow-up, and determine whether open reduction and internal fixation (ORIF) or radial head arthroplasty (RHA) should be recommended for surgical treatment. Methods. Patients who underwent surgery for complex radial head fractures (Mason type III, ≥ three fragments) were divided into two groups (ORIF and RHA) and propensity score matching was used to individually match patients based on patient characteristics. Ultimately, 84 patients were included in this study. After a mean follow-up of 4.1 years (2.0 to 9.5), patients were invited for clinical and radiological assessment. The Mayo Elbow Performance Score (MEPS), Oxford Elbow Score (OES), and Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire score were evaluated. Results. Patients treated with ORIF showed significantly better postoperative range of motion for flexion and extension (121.1° (SD 16.4°) vs 108.1° (SD 25.8°); p = 0.018). Postoperative functional scores also showed significantly better results in the ORIF group (MEPS 90.1 (SD 13.6) vs 78 (SD 20.5); p = 0.004). There was no significant difference between the groups in terms of the complication rate (RHA 23.8% (n = 10) vs ORIF 26.2% (n = 11)). Implant-related complications occurred in six cases (14.3%) in the RHA group and in five cases (11.9%) in the ORIF group. Conclusion. Irrespective of the patient’s age, sex, type of injury, or number of fracture fragments, ORIF of the radial head should be attempted initially, if a stable reconstruction can be achieved, as it seems to provide a superior postoperative outcome for the patient compared to primary RHA. If reconstruction is not feasible, RHA is still a viable alternative. In the surgical treatment of complex radial head fractures, reconstruction shows superior postoperative outcomes compared to RHA. Good postoperative results can be achieved even after failed reconstruction and conversion to secondary RHA. Therefore, we encourage surgeons to favour reconstruction of complex radial head fractures, regardless of injury type or number of fragments, as long as a stable fixation can be achieved. Cite this article: Bone Joint J 2024;106-B(10):1158–1164


Bone & Joint Open
Vol. 5, Issue 9 | Pages 749 - 757
12 Sep 2024
Hajialiloo Sami S Kargar Shooroki K Ammar W Nahvizadeh S Mohammadi M Dehghani R Toloue B

Aims. The ulna is an extremely rare location for primary bone tumours of the elbow in paediatrics. Although several reconstruction options are available, the optimal reconstruction method is still unknown due to the rarity of proximal ulna tumours. In this study, we report the outcomes of osteoarticular ulna allograft for the reconstruction of proximal ulna tumours. Methods. Medical profiles of 13 patients, who between March 2004 and November 2021 underwent osteoarticular ulna allograft reconstruction after the resection of the proximal ulna tumour, were retrospectively reviewed. The outcomes were measured clinically by the assessment of elbow range of motion (ROM), stability, and function, and radiologically by the assessment of allograft-host junction union, recurrence, and joint degeneration. The elbow function was assessed objectively by the Musculoskeletal Tumor Society (MSTS) score and subjectively by the Toronto Extremity Salvage Score (TESS) and Mayo Elbow Performance Score (MEPS) questionnaire. Results. The mean follow-up of patients was 60.3 months (SD 28.5). The mean elbow flexion-extension ROM was 95.8° (SD 21). The mean MSTS of the patients was 84.4 (SD 8.2), the mean TESS was 83.8 (SD 6.7), and the mean MEPS was 79.2 (SD 11.5). All the patients had radiological union at the osteotomy site. Symptomatic osteoarthritic change was observed in three patients (23%), one of whom ended up with elbow joint fusion. Two patients (15.4%) had recurrence during the follow-up period. Surgical complications included two allograft fractures, two plate fractures, three medial instabilities, and two infections. Conclusion. Osteoarticular ulna allograft reconstruction provides acceptable functional outcomes. Despite a high rate of complications, it is still a valuable reconstruction method, particularly in skeletally immature patients who need their distal humerus physis for the rest of hand growth. Cite this article: Bone Jt Open 2024;5(9):749–757


The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 747 - 757
1 Jun 2022
Liang H Yang Y Guo W Yan L Tang X Li D Qu H Zang J Du Z

Aims. The aim of this study was to investigate the feasibility of application of a 3D-printed megaprosthesis with hemiarthroplasty design for defects of the distal humerus or proximal ulna following tumour resection. Methods. From June 2018 to January 2020, 13 patients with aggressive or malignant tumours involving the distal humerus (n = 8) or proximal ulna (n = 5) were treated by en bloc resection and reconstruction with a 3D-printed megaprosthesis with hemiarthroplasty, designed in our centre. In this paper, we summarize the baseline and operative data, oncological outcome, complication profiles, and functional status of these patients. Results. Preparation of the prosthesis was a mean of 8.0 days (SD 1.5), during which time no patients experienced tumour progression. The mean operating time and intraoperative blood loss were 158.1 minutes (SD 67.6) and 176.9 ml (SD 187.8), respectively. All of the prostheses were implanted successfully. During a mean follow-up of 25.7 months (SD 7.8), no patients died, but four had complications (two superficial wound problems, one temporary palsy of radial nerve, and one dislocation). No aseptic loosening, structural failure, infection, heterotopic ossification, or degenerative arthritis was seen in this study. The mean flexion of the elbow was 119.6° (SD 15.9°) and the mean extension lag was 11.9° (SD 13.8°). The mean Musculoskeletal Tumor Society 93 score and Mayo Elbow Performance Score were 28.4 (SD 0.9) and 97.7 (SD 4.4), respectively. Conclusion. The custom-made, 3D-printed megaprosthesis with hemiarthroplasty is a feasible option for functional reconstruction after resection of a tumour in the distal humerus or proximal ulna. Cite this article: Bone Joint J 2022;104-B(6):747–757


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1327 - 1332
1 Nov 2024
Ameztoy Gallego J Diez Sanchez B Vaquero-Picado A Antuña S Barco R

Aims. In patients with a failed radial head arthroplasty (RHA), simple removal of the implant is an option. However, there is little information in the literature about the outcome of this procedure. The aim of this study was to review the mid-term clinical and radiological results, and the rate of complications and removal of the implant, in patients whose initial RHA was undertaken acutely for trauma involving the elbow. Methods. A total of 11 patients in whom removal of a RHA without reimplantation was undertaken as a revision procedure were reviewed at a mean follow-up of 8.4 years (6 to 11). The range of motion (ROM) and stability of the elbow were recorded. Pain was assessed using a visual analogue scale (VAS). The functional outcome was assessed using the Mayo Elbow Performance Score (MEPS), the Oxford Elbow Score (OES), and the Disabilities of the Arm, Shoulder and Hand questionnaire (DASH). Radiological examination included the assessment of heterotopic ossification (HO), implant loosening, capitellar erosion, overlengthening, and osteoarthritis. Complications and the rate of further surgery were also recorded. Results. The indications for removal of the implant were stiffness in five patients, aseptic loosening in five, and pain attributed to the RHA in three. The mean time interval between RHA for trauma to removal was ten months (7 to 21). Preoperatively, three patients had overlengthening of the implant, three had capitellar erosion, six had HO, and four had radiological evidence of loosening. At the final follow-up, the mean the flexion-extension arc improved significantly by 38.2° (95% CI 20 to 59; p = 0.002) and the mean arc of prono-supination improved significantly by 20° (95% CI 0 to 72.5; p = 0.035). The mean pain VAS score improved significantly by 3.5 (95% CI 2 to 5.5; p = 0.004). The mean MEPS improved significantly by 27.5 (95% CI 17.5 to 42.5; p = 0.002). The mean OES improved significantly by 9 (95% CI 2.5 to 14; p = 0.012), and the mean DASH score improved significantly by 23.5 (95% CI 7.5 to 31.6; p = 0.012). Ten patients (91%) had HO and osteoarthritis. Two patients underwent further surgery due to stiffness and pain, respectively. Conclusion. Simple removal of the implant at revision surgery following a failed RHA introduced following trauma provides satisfactory mid-term results with an acceptable risk of complications. Osteoarthritis, instability, and radioulnar impingement were not problems in this series. Cite this article: Bone Joint J 2024;106-B(11):1327–1332


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1620 - 1628
1 Dec 2020
Klug A Nagy A Gramlich Y Hoffmann R

Aims. To evaluate the outcomes of terrible triad injuries (TTIs) in mid-term follow-up and determine whether surgical treatment of the radial head influences clinical and radiological outcomes. Methods. Follow-up assessment of 88 patients with TTI (48 women, 40 men; mean age 57 years (18 to 82)) was performed after a mean of 4.5 years (2.0 to 9.4). The Mayo Elbow Performance Score (MEPS), Oxford Elbow Score (OES), and Disabilities of the Arm, Shoulder and Hand (DASH) score were evaluated. Radiographs of all patients were analyzed. Fracture types included 13 Mason type I, 16 type II, and 59 type III. Surgical treatment consisted of open reduction and internal fixation (ORIF) in all type II and reconstructable type III fractures, while radial head arthroplasty (RHA) was performed if reconstruction was not possible. Results. At follow-up the mean MEPS was 87.1 (20 to 100); mean OES, 36.9 (6 to 48); and mean DASH score, 18.6 (0 to 90). Mean movement was 118° (30° to 150°) for extension to flexion and 162° (90° to 180°) for pronation to supination. The overall reoperation rate was 24%, with nine ORIF, ten RHA, and two patients without treatment to the radial head needing surgical revision. When treated with RHA, Mason type III fractures exhibited significantly inferior outcomes. Suboptimal results were also identified in patients with degenerative or heterotopic changes on their latest radiograph. In contrast, more favourable outcomes were detected in patients with successful radial head reconstruction after Mason type III fractures. Conclusion. Using a standardized protocol, sufficient elbow stability and good outcomes can be achieved in most TTIs. Although some bias in treatment allocation, with more severe injuries assigned to RHA, cannot be completely omitted, treatment of radial head fractures may have an independent effect on outcome, as patients subjected to RHA showed significantly inferior results compared to those subjected to reconstruction, in terms of elbow function, incidence of arthrosis, and postoperative complications. As RHA showed no apparent advantage in Mason type III injuries between the two treatment groups, we recommend reconstruction, providing stable fixation can be achieved. Cite this article: Bone Joint J 2020;102-B(12):1620–1628


The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1362 - 1369
1 Nov 2019
Giannicola G Calella P Bigazzi P Mantovani A Spinello P Cinotti G

Aims. The aim of this study was to analyze the results of two radiocapitellar prostheses in a large case series followed prospectively, with medium-term follow-up. Patients and Methods. A total of 31 patients with a mean age of 54 years (27 to 73) were analyzed; nine had primary osteoarthritis (OA) and 17 had post-traumatic OA, three had capitellar osteonecrosis, and two had a fracture. Overall, 17 Lateral Resurfacing Elbow (LRE) and 14 Uni-Elbow Radio-Capitellum Implant (UNI-E) arthroplasties were performed. Pre- and postoperative assessment involved the Mayo Elbow Performance Score (MEPS), the Quick Disabilities of the Arm, Shoulder and Hand (Q-DASH) score, and the modified American Shoulder Elbow Surgeons (m-ASES) score. Results. The mean follow-up was 6.8 years (3.8 to 11.5). The mean MEPS, m-ASES, and Q-DASH scores improved significantly by 50 (p < 0.001), 55 (p < 0.001), and 54 points (p < 0.001), respectively, with no differences being detected between the implants. Preoperative pronation and supination were worse in patients in whom the UNI-E was used. Two patients with the UNI-E implant had asymptomatic evidence of gross loosening. Conclusion. Radiocapitellar arthroplasty yielded a significant improvement in elbow function at a mean follow-up of 6.8 years, with a high implant survival rate when the LRE was used in patients with primary or post-traumatic OA, without radial head deformity, and when the UNI-E was used in patients in whom radial head excision was indicated. Cite this article: Bone Joint J 2019;101-B:1362–1369


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 967 - 980
1 Aug 2020
Chou TA Ma H Wang J Tsai S Chen C Wu P Chen W

Aims. The aims of this study were to validate the outcome of total elbow arthroplasty (TEA) in patients with rheumatoid arthritis (RA), and to identify factors that affect the outcome. Methods. We searched PubMed, MEDLINE, Cochrane Reviews, and Embase from between January 2003 and March 2019. The primary aim was to determine the implant failure rate, the mode of failure, and risk factors predisposing to failure. A secondary aim was to identify the overall complication rate, associated risk factors, and clinical performance. A meta-regression analysis was completed to identify the association between each parameter with the outcome. Results. A total of 38 studies including 2,118 TEAs were included in the study. The mean follow-up was 80.9 months (8.2 to 156). The implant failure and complication rates were 16.1% (95% confidence interval (CI) 0.128 to 0.200) and 24.5% (95% CI 0.203 to 0.293), respectively. Aseptic loosening was the most common mode of failure (9.5%; 95% CI 0.071 to 0.124). The mean postoperative ranges of motion (ROMs) were: flexion 131.5° (124.2° to 138.8°), extension 29.3° (26.8° to 31.9°), pronation 74.0° (67.8° to 80.2°), and supination 72.5° (69.5° to 75.5°), and the mean postoperative Mayo Elbow Performance Score (MEPS) was 89.3 (95% CI 86.9 to 91.6). The meta-regression analysis identified that younger patients and implants with an unlinked design correlated with higher failure rates. Younger patients were associated with increased complications, while female patients and an unlinked prosthesis were associated with aseptic loosening. Conclusion. TEA continues to provide satisfactory results for patients with RA. However, it is associated with a substantially higher implant failure and complication rates compared with hip and knee arthroplasties. The patient’s age, sex, and whether cemented fixation and unlinked prosthesis were used can influence the outcome. Level of Evidence: Therapeutic Level IV. Cite this article: Bone Joint J 2020;102-B(8):967–980


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1512 - 1519
1 Dec 2019
Klug A Konrad F Gramlich Y Hoffmann R Schmidt-Horlohé K

Aims. The aim of this study was to evaluate the outcome of Monteggia-like lesions at midterm follow-up and to determine whether the surgical treatment of the radial head influences the clinical and radiological results. Patients and Methods. A total of 78 patients with a Monteggia-like lesion, including 44 women and 34 men with a mean age of 54.7 years (19 to 80), were available for assessment after a mean 4.6 years (2 to 9.2). The outcome was assessed using the Mayo Elbow Performance Score (MEPS), Oxford Elbow Score (OES), Mayo Modified Wrist Score (MMWS), and The Disabilities of the Arm, Shoulder and Hand (DASH) score. Radiographs were analyzed for all patients. A total of 12 Mason type I, 16 type II, and 36 type III fractures were included. Surgical treatment consisted of screw fixation for all type II and reconstructable type III fractures, while radial head arthroplasty (RHA) or excision was performed if reconstruction was not possible. Results. The mean MEPS was 88.9 (40 to 100), mean OES was 40.1 (25 to 48), mean MMWS was 88.1 (50 to 100), mean DASH score was 14.7 (0 to 60.2), and mean movement was 114° (. sd. 27) in extension/flexion and 155° (. sd. 37) in pronation/supination. Mason III fractures, particularly those with an associated coronoid fracture treated with RHA, had a significantly poorer outcome. Suboptimal results were also identified in patients who had degenerative changes or heterotopic ossification on their latest radiograph. In contrast, all patients with successful radial head reconstruction or excision had a good outcome. Conclusion. Good outcomes can be achieved in Monteggia-like lesions with Mason II and III fractures, when reconstruction is possible. Otherwise, RHA is a reliable option with satisfactory outcomes, especially in patients with ligamenteous instability. Whether the radial head should be excised remains debatable, although good results were achieved in patients with ligamentous stability and in those with complications after RHA. Cite this article: Bone Joint J 2019;101-B:1512–1519


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1489 - 1497
1 Dec 2019
Wang J Ma H Chou TA Tsai S Chen C Wu P Chen W

Aims. The aim of this meta-analysis was to compare the outcome of total elbow arthroplasty (TEA) undertaken for rheumatoid arthritis (RA) with TEA performed for post-traumatic conditions with regard to implant failure, functional outcome, and perioperative complications. Materials and Methods. We completed a comprehensive literature search on PubMed, Web of Science, Embase, and the Cochrane Library and conducted a systematic review and meta-analysis. Nine cohort studies investigated the outcome of TEA between RA and post-traumatic conditions. The preferred reporting items for systematic reviews and meta-analysis (Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA)) guidelines and Newcastle-Ottawa scale were applied to assess the quality of the included studies. We assessed three major outcome domains: implant failures (including aseptic loosening, septic loosening, bushing wear, axle failure, component disassembly, or component fracture); functional outcomes (including arc of range of movement, Mayo Elbow Performance Score (MEPS), and the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire), and perioperative complications (including deep infection, intraoperative fracture, postoperative fracture, and ulnar neuropathy). Results. This study included a total of 679 TEAs for RA (n = 482) or post-traumatic conditions (n = 197). After exclusion, all of the TEAs included in this meta-analysis were cemented with linked components. Our analysis demonstrated that the RA group was associated with a higher risk of septic loosening after TEA (odds ratio (OR) 3.96, 95% confidence interval (CI) 1.11 to 14.12), while there was an increased risk of bushing wear, axle failure, component disassembly, or component fracture in the post-traumatic group (OR 4.72, 95% CI 2.37 to 9.35). A higher MEPS (standardized mean difference 0.634, 95% CI 0.379 to 0.890) was found in the RA group. There were no significant differences in arc of range of movement, DASH questionnaire, and risk of aseptic loosening, deep infection, perioperative fracture, or ulnar neuropathy. Conclusion. The aetiology of TEA surgery appears to have an impact on the outcome in terms of specific modes of implant failures. RA patients might have a better functional outcome after TEA surgery. Cite this article: Bone Joint J 2019;101-B:1489–1497


The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 818 - 823
1 Jun 2017
Kodama A Mizuseki T Adachi N

Aims. We assessed the long-term (more than ten-year) outcomes of the Kudo type-5 elbow prosthesis in patients with rheumatoid arthritis (RA). Materials and Methods. We reviewed 41 elbows (Larsen Grade IV, n = 21; Grade V, n = 20) in 31 patients with RA who had undergone a Kudo type-5 total elbow arthroplasty (TEA) between 1994 and 2003, and had been followed up for more than ten years. The humeral component was cementless and the all-polyethylene ulnar component cemented in every patient. Clinical outcome was assessed using the Mayo elbow performance score. We calculated the revision rate and evaluated potential risk factors for revision. The duration of follow-up was a mean 141 months (120 to 203). Results. Aseptic loosening of the ulnar component occurred in 11 elbows. There was no radiolucency around any humeral component. There was one deep infection. The survival rate according to Kaplan-Meier survivorship analysis was 87.8% after five years and 70.7% after ten years. The range of extension/flexion was a mean -38° (-80° to 0°)/105° (30° to 150°) before surgery and -40° (-70° to -20°)/132° (100° to 150°) at the final follow-up, while the mean Mayo elbow performance score was 43 before surgery and 80 at final follow-up. Disease duration of RA up to the TEA of < 15 years and a pre-operative range of movement (ROM) of > 85° were significant risk factors for revision or aseptic loosening. Conclusion. Although Kudo type-5 prostheses gave satisfactory results in the short-term, aseptic loosening increased after five years. In most cases, elbow function was maintained in the long-term without loosening of the implant. A short duration from the onset of RA to TEA and a large pre-operative ROM were significant risk factors for revision or aseptic loosening. Cite this article: Bone Joint J 2017;99-B:818–23


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 4 | Pages 466 - 473
1 Apr 2008
Dawson J Doll H Boller I Fitzpatrick R Little C Rees J Jenkinson C Carr AJ

We developed a questionnaire to assess patient-reported outcome after surgery of the elbow from interviews with patients. Initially, 17 possible items with five response options were included. A prospective study of 104 patients (107 elbow operations) was carried out to analyse the underlying factor structure, dimensionality, internal and test-retest reliability, construct validity and responsiveness of the questionnaire items. This was compared with the Mayo Elbow performance score clinical scale, the Disabilities of the Arm, Shoulder and Hand questionnaire, and the Short-Form (SF-36) General Health Survey. In total, five questions were considered inappropriate, which resulted in the final 12-item questionnaire, which has been referred to as the Oxford elbow score. This comprises three unidimensional domains, ‘elbow function’, ‘pain’ and ‘social-psychological’; with each domain comprising four items with good measurement properties. This new 12-item Oxford elbow score is a valid measure of the outcome of surgery of the elbow


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 3 | Pages 343 - 348
1 Mar 2008
Prasad N Dent C

We analysed the outcome of the Coonrad-Morrey total elbow replacement used for fracture of the distal humerus in elderly patients with no evidence of inflammatory arthritis and compared the results for early versus delayed treatment. We studied a total of 32 patients with 15 in the early treatment group and 17 in the delayed treatment group. The mean follow-up was 56.1 months (18 to 88). The percentage of excellent to good results based on the Mayo elbow performance score was not significantly different, 84% in the early group and 79% in the delayed group. Subjective satisfaction was 92% in both the groups. One patient in the early group developed chronic regional pain syndrome and another type 4 aseptic loosening. Two elbows in the early group also showed type 1 radiological loosening. Two patients in the delayed group had an infection, two an ulnar nerve palsy, one developed heterotopic ossification and one type 4 aseptic loosening. Two elbows in this group also showed type 1 radiological loosening. The Kaplan-Meier survivorship analysis for the early and delayed treatment groups was 93% at 88 months and 76% at 84 months, respectively. No significant difference was found between the two groups


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 12 | Pages 1685 - 1689
1 Dec 2010
Gokaraju K Miles J Parratt MTR Blunn GW Pollock RC Skinner JA Cannon SR Briggs TWR

We have reviewed five adult patients treated with endoprosthetic reconstruction of the proximal radius following resection of non-traumatic lesions. The patients had a mean age of 33.4 years (20 to 60) at the time of surgery and the mean follow-up was 7.6 years (0.8 to 16). Following surgery, all elbows were clinically stable and there was 100% survivorship of the prosthesis. Evaluation of function was assessed clinically and by the Mayo Elbow Performance Score, achieving a mean of 86% (70 to 100). Results at medium-term follow-up are encouraging with regards to elbow stability, implant survivorship and functional outcome


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1499 - 1505
1 Nov 2018
Mazhar FN Ebrahimi H Jafari D Mirzaei A

Aims. The crucial role of the radial head in the stability of the elbow in terrible triad injury is acknowledged. This retrospective study aims to compare the results of resection of a severely comminuted radial head with or without prosthetic arthroplasty as part of the reconstruction for this injury. Patients and Methods. The outcome of radial head resection was compared with prosthetic arthroplasty in 29 and 15 patients with terrible triad injuries, respectively. There were ten female patients (34.5%) in the resection group and six female patients (40%) in the prosthesis group. The mean age was 40.7 years (. sd. 13.6) in the resection group and 36 years (. sd. 9.4) in the prosthesis group. The mean follow-up of the patients was 24.4 months (. sd. 12) in the resection group and 45.8 months (. sd. 6.8) in the prosthesis group. Outcome measures included visual analogue scale (VAS) for pain, Mayo Elbow Performance Score (MEPS), Disabilities of Arm, Shoulder and Hand (DASH) Score, and range of movement. Postoperative radiological complications were also recorded. Results. The mean ranges of extension, flexion, supination, and pronation were not significantly different between the two study groups (p = 0.75, p = 0.65, p = 0.82, and p = 0.68, respectively). The mean VAS score, DASH score, and MEPS of the two groups were also not statistically significantly different (p = 0.93, p = 0.19, and p = 0.32, respectively). At the final visit, the elbow was stable in all patients. No patient was found to have developed an Essex–Lopresti injury. Osteoarthritis grade I and II was observed in five and three patients of the resection group, respectively, and four and one patients of the arthroplasty group, respectively. Conclusion. The outcome of patients undergoing treatment for terrible triad injuries is similar whether the patient’s radial head was excised or replaced. Cite this article: Bone Joint J 2018;100-B:1499–505


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 62 - 65
1 Jan 2007
Ito H Matsumoto T Yoshitomi H Kakinoki R Nakamura T

We compared the outcome of peri-operative humeral condylar fractures in patients undergoing a Coonrad-Morrey semiconstrained total elbow replacement with that of patients with rheumatoid arthritis undergoing the same procedure without fractures. In a consecutive series of 40 elbows in 33 patients, 13 elbows had a fracture in either condyle peri-operatively, and 27 elbows were intact. The fractured condyle was either fixed internally or excised. We found no statistical difference in the patients’ background, such as age, length of follow-up, immobilisation period, Larsen’s radiological grade, or Steinbrocker’s stage and functional class. There was also no statistical difference between the groups in relation to the Mayo Elbow Performance Score, muscle strength, range of movement, or radiolucency around the implants at a mean of 4.8 years (1.1 to 8.0) follow-up. We conclude that fractured condyles can be successfully treated with either internal fixation or excision, and cause no harmful effect


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 5 | Pages 632 - 635
1 May 2009
Adams JE Hoskin TL Morrey BF Steinmann SP

A series of 103 acute fractures of the coronoid process of the ulna in 101 patients was reviewed to determine their frequency. The Regan-Morrey classification, treatment, associated injuries, course and outcomes were evaluated. Of the 103 fractures, 34 were type IA, 17 type IB, ten type IIA, 19 type IIB, ten type IIIA and 13 type IIIB. A total of 44 type-I fractures (86%) were treated conservatively, while 22 type-II (76%) and all type-III fractures were managed by operation. At follow-up at a mean of 3.4 years (1 to 8.9) the range of movement differed significantly between the types of fracture (p = 0.002). Patients with associated injuries had a lower Mayo elbow performance score (p = 0.03), less extension (p = 0.03), more pain (p = 0.007) and less pronosupination (p = 0.004), than those without associated injuries. The presence of a fracture of the radial head had the greatest effect on outcome. An improvement in outcome relative to that of a previous series was noted, perhaps because of more aggressive management and early mobilisation. While not providing complete information about the true details of a fracture and its nature, the Regan-Morrey classification is useful as a broad index of severity and prognosis


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1460 - 1463
1 Nov 2006
Landor I Vavrik P Jahoda D Guttler K Sosna A

We assessed the long-term results of 58 Souter-Strathclyde total elbow replacements in 49 patients with rheumatoid arthritis. The mean length of follow-up was 9.5 years (0.7 to 16.7). The mean pre-operative Mayo Elbow Performance Score was 30 (15 to 80) and at final follow-up was 82 (60 to 95). A total of 13 elbows (22.4%) were revised, ten (17.2%) for aseptic loosening, one (1.7%) for instability, one (1.7%) for secondary loosening after fracture, and one elbow (1.7%) was removed because of deep infection. The Kaplan-Meier survival rate was 70% and 53% at ten and 16 years, respectively. Failure of the ulnar component was found to be the main problem in relation to the loosening. Anterior transposition of the ulnar nerve had no influence on ulnar nerve paresthaesiae in these patients


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 3 | Pages 330 - 334
1 Mar 2007
Cesar M Roussanne Y Bonnel F Canovas F

Between 1993 and 2002, 58 GSB III total elbow replacements were implanted in 45 patients with rheumatoid arthritis by the same surgeon. At the most recent follow-up, five patients had died (five elbows) and six (nine elbows) had been lost to follow-up, leaving 44 total elbow replacements in 34 patients available for clinical and radiological review at a mean follow-up of 74 months (25 to 143). There were 26 women and eight men with a mean age at operation of 55.7 years (24 to 77). At the latest follow-up, 31 excellent (70%), six good (14%), three fair (7%) and four poor (9%) results were noted according to the Mayo elbow performance score. Five humeral (11%) and one ulnar (2%) component were loose according to radiological criteria (type III or type IV). Of the 44 prostheses, two (5%) had been revised, one for type-IV humeral loosening after follow-up for ten years and one for fracture of the ulnar component. Seven elbows had post-operative dysfunction of the ulnar nerve, which was transient in five and permanent in two. Despite an increased incidence of loosening with time, the GSB III prosthesis has given favourable mid-term results in patients with rheumatoid arthritis


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 1 | Pages 54 - 61
1 Jan 2005
Sanchez-Sotelo J Morrey BF O’Driscoll SW

We describe the intermediate results of lateral ligamentous repair or reconstruction for posterolateral rotatory instability of the elbow. Between 1986 and 1999, we performed 12 direct repairs and 33 ligament reconstructions with a tendon autograft. One patient was lost to follow-up and 44 were retrospectively studied at a mean of six years (2 to 15). Surgery restored stability in all except five patients. In two the elbow became stable after a second procedure. The mean post-operative Mayo elbow performance score was 85 points (60 to 100). The result was classified as excellent in 19, good in 13, fair in seven and poor in five patients. Thirty-eight patients (86%) were subjectively satisfied with the outcome of the operation. Better results were obtained in patients with a post-traumatic aetiology (p = 0.03), those with subjective symptoms of instability at presentation (p = 0.006) and those who had an augmented reconstruction using a tendon graft (p = 0.04). Reconstruction using a tendon graft seems to provide better results than ligament repair and the results do not seem to deteriorate with time. The outcome of this procedure is less predictable in patients with no subjective instability


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 1 | Pages 78 - 83
1 Jan 2006
Sneftrup SB Jensen SL Johannsen HV Søjbjerg JO

We studied retrospectively the results of revision arthroplasty of the elbow using a linked Coonrad-Morrey implant in 23 patients (24 elbows) after a mean follow-up period of 55 months. According to the Mayo Elbow Performance Score, 19 elbows were satisfactory, nine were excellent and ten good. The median total score had improved from 35 points (20 to 75) before the primary arthroplasty to 85 points (40 to 100) at the latest follow-up. There was a marked relief of pain, but the range of movement showed no overall improvement. Two patients had a second revision because of infection and two for aseptic loosening. The estimated five-year survival rate of the prosthesis was 83.1% (95% confidence interval 61.1 to 93.3). Revision elbow arthroplasty using the Coonrad-Morrey implant provided satisfactory results but with complications occurring in 13 cases


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 760 - 764
1 Jun 2006
Dotzis A Cochu G Mabit C Charissoux JL Arnaud JP

Excision is not a suitable treatment for all comminuted fractures of the radial head. In elbows where instability can be predicted, a replacement arthroplasty of the radial head is more effective. The aim of this paper was to present the medium-term results of the Judet floating radial head prosthesis. This operation was performed on 14 patients between 1992 and 2003, of whom 12 were reviewed at a mean follow-up of five years and three months (1 to 12 years). The outcome was assessed using the Mayo elbow performance score and a modified Disability of Arm Shoulder Hand (DASH) questionnaire. There were six excellent results, four good, one fair and one poor, as graded by the Mayo score. The mean DASH score was 23.9/100 (0 to 65.8/100). The only significant complication occurred in one patient who developed a severe complex regional pain syndrome. There were no patients with secondary instability of the elbow, implant loosening, cubitus valgus, osteoporosis of the capitellum, or pain in the forearm and wrist. Our experience, combined with that of other authors using this device, has encouraged us to continue using the Judet prosthesis in comminuted fractures of the elbow where instability is a potential problem


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 7 | Pages 920 - 924
1 Jul 2006
Mori T Kudo H Iwano K Juji T

We studied 11 patients (14 elbows) with gross rheumatoid deformity of the elbow, treated by total arthroplasty using the Kudo type-5 unlinked prosthesis, and who were evaluated between five and 11 years after operation. Massive bone defects were augmented by autogenous bone grafts. There were no major complications such as infection, subluxation or loosening. In most elbows relief from pain and stability were achieved. The results, according to the Mayo Elbow Performance Score, were excellent in eight, good in five and fair in one. In most elbows there was minimal or no resorption of the grafted bone. There were no radiolucent lines around the stems of the cementless components. This study shows that even highly unstable rheumatoid elbows can be replaced successfully using an unlinked prosthesis, with augmentation by grafting for major defects of bone


The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 610 - 616
1 May 2018
Giannicola G Bullitta G Rotini R Murena L Blonna D Iapicca M Restuccia G Merolla G Fontana M Greco A Scacchi M Cinotti G

Aims. The aim of the study was to analyze the results of primary tendon reinsertion in acute and chronic distal triceps tendon ruptures (DTTRs) in the general population. Patients and Methods. A total of 28 patients were operated on for primary DTTR reinsertions, including 21 male patients and seven female patients with a mean age of 45 years (14 to 76). Of these patients, 23 sustained an acute DTTR and five had a chronic injury. One patient had a non-simultaneous bilateral DTTR. Seven patients had DTTR-associated ipsilateral fracture or dislocation. Comorbidities were present in four patients. Surgical treatment included transosseous and suture-anchors reinsertion in 22 and seven DTTRs, respectively. The clinical evaluation was performed using Mayo Elbow Performance Score (MEPS), the modified American Shoulder and Elbow Surgeons Score (m-ASES), the Quick Disabilities of the Arm, Shoulder and Hand score (QuickDASH), and the Medical Research Council (MRC) Scale. Results. A total of 27 patients (28 DTTRs) were available for review at a mean of 47.5 months (12 to 204). The mean MEPS, QuickDASH, and m-ASES scores were 94 (60 to 100), 10 (0 to 52), and 94 (58 to 100), respectively. Satisfactory results were observed in 26 cases (93%). Muscle strength was 5/5 and 4/5 in 18 and ten DTTRs, respectively. One patient with chronic renal failure experienced a traumatic rerupture of distal triceps. One patient (1 DTTR) experienced mild elbow stiffness. Conclusion. Primary repair of acute and chronic DTTRs in a general population yields satisfactory results in the majority of patients with a low rerupture rate. Cite this article: Bone Joint J 2018;100-B:610–16


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 10 | Pages 1369 - 1374
1 Oct 2005
Athwal GS Chin PY Adams RA Morrey BF

We reviewed 20 patients who had undergone a Coonrad-Morrey total elbow arthroplasty after resection of a primary or metastatic tumour from the elbow or distal humerus between 1980 and 2002. Eighteen patients underwent reconstruction for palliative treatment with restoration of function after intralesional surgery and two after excision of a primary bone tumour. The mean follow-up was 30 months (1 to 192). Five patients (25%) were alive at the final follow-up; 14 (70%) had died of their disease and one of unrelated causes. Local control was achieved in 15 patients (75%). The mean Mayo Elbow Performance Score improved from 22 (5 to 45) to 75 points (55 to 95). Four reconstructions (20%) failed and required revision. Seven patients (35%) had early complications, the most frequent being nerve injury (25%). There were no infections or wound complications although 18 patients (90%) had radiotherapy, chemotherapy or both. The Coonrad-Morrey total elbow arthroplasty provides good relief from pain and a good functional outcome after resection of tumours of the elbow. The rates of complications involving local recurrence of tumour (25%) and nerve injury (25%) are of concern


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 9 | Pages 1273 - 1277
1 Sep 2010
Larson AN Adams RA Morrey BF

Between 1996 and 2008, nine patients with severe post-traumatic arthritis underwent revision of a failed interposition arthroplasty of the elbow with a further interposition procedure using an allograft of tendo Achillis at a mean of 5.6 years (0.7 to 13.1) after the initial procedure. There were eight men and one woman with a mean age of 47 years (36 to 56). The mean follow-up was 4.7 years (2 to 8). The mean Mayo Elbow Performance score improved from 49 (15 to 65) pre-operatively to 73 (55 to 95) (p = 0.04). The mean Disability of the Arm, Shoulder and Hand score was 26 (7 to 42). One patient was unavailable for clinical follow-up and one underwent total elbow replacement three months post-operatively. Of the remaining patients, one had an excellent, two had good, three fair and one a poor result. Subjectively, five of the nine patients were satisfied. Four continued manual labour. Revision interposition arthroplasty is an option for young, active patients with severe post-traumatic arthritis who require both mobility and durability of the elbow


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 9 | Pages 1198 - 1204
1 Sep 2008
Peden JP Morrey BF

This study reports our experience with total elbow replacement for fused elbows. Between 1982 and 2004, 13 patients with spontaneously ankylosed elbows were treated with a linked semi-constrained non-custom total elbow implant. The mean age at operation was 54 years (24 to 80). The stiffness was a result of trauma in ten elbows, juvenile rheumatoid arthritis in one, and rheumatoid arthritis in two. The patients were followed for a mean of 12 years (2 to 26) and were evaluated clinically using the Mayo Elbow Performance Score, as well as radiologically. A mean arc from 37° of extension to 118° of flexion was achieved. Outcomes were good or excellent for seven elbows at final review. Ten patients felt better or much better after total elbow replacement. However, there was a high complication rate and re-operation was required in over half of patients. Two developed peri-operative soft-tissue breakdown requiring debridement. A muscle flap with skin grafting was used for soft-tissue cover in one. Revision was undertaken in one elbow following fracture of the ulnar component. Three patients developed a deep infection. Three elbows were manipulated under anaesthesia for post-operative stiffness. Prophylactic measures for heterotopic ossification were unsuccessful. Total elbow replacement for the ankylosed elbow should be performed with caution. However, the outcome can be reliable in the long term and have a markedly positive impact on patient function and satisfaction. The high potential for complications must be considered. We consider total elbow replacement to be an acceptable procedure in selected patients with reasonable expectations


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1416 - 1421
1 Oct 2010
Qureshi F Draviaraj KP Stanley D

Between September 1993 and September 1996, we performed 34 Kudo 5 total elbow replacements in 31 rheumatoid patients. All 22 surviving patients were reviewed at a mean of 11.9 years (10 to 14). Their mean age was 56 years (37 to 78) at the time of operation. All had Larsen grade IV or V rheumatoid changes on X-ray. Nine (three bilateral replacements and six unilateral) had died from unrelated causes. One who had died before ten years underwent revision for dislocation. Of the 22 total elbow replacements reviewed six had required revision, four for aseptic loosening (one humeral and three ulnar) and two for infection. Post-operatively, one patient had neuropraxia of the ulnar nerve and one of the radial nerve. Two patients had valgus tilting of the ulnar component. With revision as the endpoint, the mean survival time for the prosthesis was 11.3 years (95% confidence interval (10 to 13) and the estimated survival of the prosthesis at 12 years according to Kaplan-Meier survival analysis was 74% (95% confidence interval 0.53 to 0.91). Of the 16 surviving implants, ten were free from pain, four had mild pain and two moderate. The mean arc of flexion/extension of the elbow was 106° (65° to 130°) with pronation/supination of 90° (30° to 150°) with the joint at 90° of flexion. The mean Mayo elbow performance score was 82 (60 to 100) with five excellent, ten good and one fair result. Good long-term results can be expected using the Kudo 5 total elbow replacement in patients with rheumatoid disease, with a low incidence of loosening of the components


The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 82 - 87
1 Jan 2014
Duquin TR Jacobson JA Schleck CD Larson DR Sanchez-Sotelo J Morrey BF

Treatment of an infected total elbow replacement (TER) is often successful in eradicating or suppressing the infection. However, the extensor mechanism may be compromised by both the infection and the surgery. The goal of this study was to assess triceps function in patients treated for deep infection complicating a TER. Between 1976 and 2007 a total of 217 TERs in 207 patients were treated for infection of a TER at our institution. Superficial infections and those that underwent resection arthroplasty were excluded, leaving 93 TERs. Triceps function was assessed by examination and a questionnaire. Outcome was measured using the Mayo Elbow Performance Score (MEPS). Triceps weakness was identified in 51 TERs (49 patients, 55%). At a mean follow-up of five years (0.8 to 34), the extensor mechanism was intact in 13 patients, with the remaining 38 having bone or soft-tissue loss. The mean MEPS was 70 points (5 to 100), with a mean functional score of 18 (0 to 25) of a possible 25 points. Infection following TER can often be eradicated; however, triceps weakness occurs in more than half of the patients and may represent a major functional problem. Cite this article: Bone Joint J 2014;96-B:82–7


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 80 - 85
1 Jan 2012
Malone AA Sanchez JS Adams R Morrey B

We report the effectiveness of revision of total elbow replacement by re-cementing. Between 1982 and 2004, 53 elbows in 52 patients were treated with re-cementing of a total elbow replacement into part or all of the existing cement mantle or into the debrided host-bone interface, without the use of structural bone augmentation or a custom prosthesis. The original implant revision was still in situ and functional in 42 of 53 elbows (79%) at a mean of 94.5 months (26 to 266) after surgery. In 31 of these 42 elbows (74%) the Mayo Elbow Performance Score was good or excellent. Overall, of the 53 elbows, 18 (34%) required re-operation, ten (19%) for loosening. A classification system was developed to identify those not suitable for revision by this technique, and using this we have showed that successful re-implantation is statistically correlated to properly addressing the bone deficiency for both the humeral (p = 0.005) and the ulnar (p = 0.039) components


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 8 | Pages 1107 - 1110
1 Aug 2005
Ali A Douglas H Stanley D

Sixteen patients who underwent a revision operation for nonunion of fractures of the distal humerus following previous internal fixation were reviewed at a mean follow-up of 39 months (8 to 69). The Mayo elbow performance score was excellent in 11, good in two, fair in two and poor in one. In 15 patients union was achieved and in one with an infected nonunion a subsequent bone graft was necessary in order to obtain union. Age, gender, a history of smoking, mechanism of the injury and the AO classification of the initial fracture did not correlate with the development of nonunion. In 12 patients (75%), the initial fixation was assessed as being suboptimal. The primary surgery was regarded as adequate in only three patients. Our findings suggest that the most important determinant of nonunion of a distal humeral fracture after surgery is the adequacy of fixation


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1096 - 1101
1 Aug 2015
Oizumi N Suenaga N Yoshioka C Yamane S

To prevent insufficiency of the triceps after total elbow arthroplasty, we have, since 2008, used a triceps-sparing ulnar approach. This study evaluates the clinical results and post-operative alignment of the prosthesis using this approach. We reviewed 25 elbows in 23 patients. There were five men and 18 women with a mean age of 69 years (54 to 83). There were 18 elbows with rheumatoid arthritis, six with a fracture or pseudoarthrosis and one elbow with osteoarthritis. Post-operative complications included one intra-operative fracture, one elbow with heterotopic ossification, one transient ulnar nerve palsy, and one elbow with skin necrosis, but no elbow was affected by insufficiency of the triceps. Patients were followed for a mean of 42 months (24 to 77). The mean post-operative Japanese Orthopaedic Association Elbow Score was 90.8 (51 to 100) and the mean Mayo Elbow Performance score 93.8 (65 to 100). The mean post-operative flexion/extension of the elbow was 135°/-8°. The Manual Muscle Testing score of the triceps was 5 in 23 elbows and 2 in two elbows (one patient). The mean alignment of the implants examined by 3D-CT was 2.8° pronation (standard deviation (. sd). 5.5), 0.3° valgus (. sd. 2.7), and 0.7° extension (. sd. 3.2) for the humeral component, and 9.3° pronation (. sd. 9.7), 0.3° valgus (. sd. 4.0), and 8.6° extension (. sd. 3.1) for the ulnar component. There was no radiolucent line or loosening of the implants on the final radiographs. . The triceps-sparing ulnar approach allows satisfactory alignment of the implants, is effective in preventing post-operative triceps insufficiency, and gives satisfactory short-term results. . Cite this article: 2015;97-B:1096–1101


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 1 | Pages 47 - 53
1 Jan 2005
Whaley A Morrey BF Adams R

We examined the effects of previous resection of the radial head and synovectomy on the outcome of subsequent total elbow arthroplasty in patients with rheumatoid arthritis. Fifteen elbows with a history of resection and synovectomy were compared with a control group of patients who had elbow arthroplasty with an implant of the same design. The mean age in both groups was 63 years. In the study group, resection of the radial head and synovectomy had been undertaken at a mean of 8.9 years before arthroplasty. The mean radiological follow-up for the 13 available patients in the study group was 5.89 years (0.3 to 11.0) and in the control group was 6.6 years (2.2 to 12.6). There were no revisions in either group. The mean Mayo elbow performance score improved from 29 to 96 in the study group, with similar improvement in the control group (28 to 87). The study group had excellent results in 13 elbows and good results in two. The control group had excellent results in seven and good results in six. Our experience indicates that previous resection of the radial head and synovectomy are not associated with an increased rate of revision following subsequent arthroplasty of the elbow. However, there was a higher rate of complication in the study group compared with the control group


The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 237 - 241
1 Feb 2014
Miyake J Shimada K Oka K Tanaka H Sugamoto K Yoshikawa H Murase T

We retrospectively assessed the value of identifying impinging osteophytes using dynamic computer simulation of CT scans of the elbow in assisting their arthroscopic removal in patients with osteoarthritis of the elbow. A total of 20 patients were treated (19 men and one woman, mean age 38 years (19 to 55)) and followed for a mean of 25 months (24 to 29). We located the impinging osteophytes dynamically using computerised three-dimensional models of the elbow based on CT data in three positions of flexion of the elbow. These were then removed arthroscopically and a capsular release was performed. The mean loss of extension improved from 23° (10° to 45°) pre-operatively to 9° (0° to 25°) post-operatively, and the mean flexion improved from 121° (80° to 140°) pre-operatively to 130° (110° to 145°) post-operatively. The mean Mayo Elbow Performance Score improved from 62 (30 to 85) to 95 (70 to 100) post-operatively. All patients had pain in the elbow pre-operatively which disappeared or decreased post-operatively. According to their Mayo scores, 14 patients had an excellent clinical outcome and six a good outcome; 15 were very satisfied and five were satisfied with their post-operative outcome. We recommend this technique in the surgical management of patients with osteoarthritis of the elbow. Cite this article: Bone Joint J 2014;96-B:237–41


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 5 | Pages 770 - 772
1 Sep 1997
Lee BPH Morrey BF

The short-term assessment of 14 arthroscopic synovectomies of the elbow in 11 patients with rheumatoid arthritis showed that 93% achieved a short-term rating of excellent or good on the Mayo Elbow Performance Score. At the most recent assessment at an average of 42 months, however, only 57% maintained excellent or good results; four had required total elbow replacement. Although rehabilitation is facilitated by an arthroscopic procedure the results deteriorate more rapidly than after open synovectomy. This may be due to the limitations of the arthroscopic technique and is consistent with experience of the similar procedure in the knee. Recognition of the short-term gain and the potential for serious nerve injury should be considered when offering arthroscopic synovectomy


The Bone & Joint Journal
Vol. 98-B, Issue 10 | Pages 1410 - 1417
1 Oct 2016
Sinikumpu J Victorzon S Pokka T Lindholm E Peljo T Serlo W

Aims. We present the clinical and radiographic outcome of 81 children with Gartland type I to III supracondylar humeral fractures at a minimum follow-up of ten years (mean 12.1 years; 10.3 to 16.1) following injury. Patients and Methods. The clinical and functional outcomes are compared with normal age- and gender-matched individuals. The population-based study setting was first identified from the institutional registries; the rate of participation was 76%. Controls were randomly selected from Finnish National Population Registry. Results. According to Flynn's criteria, most fractures (75.3%) resulted in a satisfactory (“good or excellent”) outcome. Satisfactory recovery was achieved in 75.0% of type I fractures treated by closed splinting (p = 0.013). Type II fractures were associated with both satisfactory (57.7%) and unsatisfactory (42.3%) results, regardless of the type of treatment, although the numbers were small in the sub groups. Most type III fractures were treated operatively, and most (76%) had a satisfactory outcome according to Flynn’s criteria (p = 0.015). Compared with none among the normal subjects, flexion of the elbow was reduced by >  10° at long-term follow-up in 20 cases (24.7%, p < 0.001) and 9 (11.1%) had a reduced flexion of > 15° (p = 0.004). In patients who had sustained a type III fracture, the carrying angle was decreased by 35.7% (from 9.8° to 6.3°; p = 0.048). All patients achieved an excellent Mayo Elbow Performance Score (mean 96.4 points). Conclusion. The long-term outcome of extension-type supracondylar humeral fractures is generally good, but not exclusively benign, with the potential for long-term pain and ulnar nerve sensitivity, and a decrease in grip strength and range of movement in type II and type III fractures. Bony remodelling cannot be relied upon to correct any residual deformity. In particular, type II fractures have impaired long-term recovery and justify individual consideration in their treatment. Cite this article: Bone Joint J 2016;98-B:1410–17


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 3 | Pages 347 - 350
1 Apr 2003
Phillips NJ Ali A Stanley D

Between 1990 and 1996 we performed 20 consecutive ulnohumeral arthroplasties for primary osteoarthritis of the elbow. The outcome was assessed using the Disabilities of Arm, Shoulder and Hand Score (DASH) and the Mayo Elbow Performance Score (MEPS) at a mean follow-up of 75 months (58 to 132). There were excellent or good results in 17 elbows (85%) using the DASH score and in 13 (65%) with the MEPS (correlation coefficient 0.79). The mean fixed flexion deformity had improved by 10° and the range of flexion by a mean of 20°. In 16 elbows (80%) the benefits of surgery had been maintained, and of 16 patients working at the time of operation, 12 (75%) had returned to the same job. There was no correlation between radiological recurrence of degenerative changes and the amount of fixed flexion deformity, the flexion arc, or the elbow scores


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 8 | Pages 1116 - 1120
1 Nov 2002
Sanchez-Sotelo J Morrey BF

Seven patients with chronic insufficiency of the triceps were treated by either a rotation flap using anconeus (4) or an allograft of tendo Achillis (3). The latter procedure was selected for patients with a large defect in whom the anconeus muscle had been devitalised. Five disruptions were in patients who had previously undergone an elbow replacement. The patients were assessed for subjective satisfaction, pain, range of movement and strength, and the results were graded using the Mayo Elbow Performance Score (MEPS). The mean follow-up was for 33 months (9 to 63). One rotation flap failed six months after operation. At the most recent follow-up, the remaining six patients had no or slight pain, restoration of a functional arc of movement and normal or slightly decreased power of extension. All six were satisfied with the outcome and were able to resume their daily activities with no limitations other than those imposed by the previous elbow replacement. The final MEPS was 100 points in five patients and 75 in one


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 2 | Pages 233 - 238
1 Mar 2000
Cheng SL Morrey BF

Between 1986 and 1994, 13 patients with mobile painful arthritic elbows were treated by distraction interposition arthroplasty using fascia lata. The mean period of follow-up was 63 months. An elbow distractor/fixator was applied for three to four weeks to separate the articular surfaces and to protect the fascial graft. Nine of the 13 patients (69%) had satisfactory relief from pain; eight (62%) had an excellent or good result by the objective criteria of the Mayo Elbow Performance score. Four have required revision to total elbow arthroplasty at a mean of 30 months with good results to date. Instability of the elbow, both before and after surgery, was found to be associated with unsatisfactory results. The rate of success when the procedure was performed for inflammatory arthritis was similar to that for post-traumatic arthritis, about 67%. Eight complications occurred in six patients, all in the group with post-traumatic arthritis. Two of these required further surgical procedures such as transposition of the ulnar nerve or repair of hernia of the fascia lata. Although less reliable than prosthetic replacement, distraction interposition arthroplasty is a useful option in the treatment of young, high-demand patients with arthritis of the elbow. It is rarely indicated in the presence of generalised inflammatory arthritis, but may be of value in those patients in whom the disease is limited primarily to the elbow


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 6 | Pages 812 - 816
1 Aug 2002
Garcia JA Mykula R Stanley D

Between 1995 and 2000, 19 consecutive patients with fractures of the distal humerus were treated by primary total elbow replacement using the Coonrad-Morrey prosthesis. No patient had inflammatory or degenerative arthritis of the elbow. The mean age at the time of injury was 73 years (61 to 95). According to the AO classification, 11 patients had suffered a C3 injury, two a B3 and two an A3. One fracture was unclassified. Two patients died from unrelated causes and one was unable to be assessed because of concurrent illness. The mean time to follow-up was three years (1 to 5.5). At follow-up 11 patients (68%) reported no pain, four (25%) had mild pain with activity and one had mild pain at rest. The mean flexion arc was 24° to 125°. The mean supination was 90° (70 to 100) and pronation 70° (50 to 110). No elbow was unstable. The mean Disabilities of the Arm, Shoulder and Hand score was 23 (0.92 to 63.3) and the mean Mayo elbow performance score was 93 (80 to 100). Of the 16 patients, 15 were satisfied with the outcome. Radiological evaluation revealed only one patient with a radiolucent line at the cement-bone interface. It was between 1 and 2 mm in length, was present on the initial postoperative radiograph and was non-progressive at the time of follow-up. Primary total elbow arthroplasty is an acceptable option for the management of comminuted fractures of the distal humerus in elderly patients when the configuration of the fracture and the quality of the bone make reconstruction difficult


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1341 - 1346
1 Oct 2009
Rosenblatt Y Young C MacDermid JC King GJW

Between 1995 and 2006, five intra-articular osteotomies of the head of the radius were performed in patients with symptomatic healed displaced articular fractures. Pre-operatively, all patients complained of persistent painful clicking on movement. Only patients with mild or no degenerative changes of the radial head and capitellum were considered for osteotomy. The operations were performed at a mean of 8.2 months (4 to 13) after injury and the patients were reviewed at a mean of 5.5 years (15 months to 12 years) after the osteotomy. The average Mayo Elbow Performance Index Score improved significantly from 74 before to 88 after operation, with four patients rated as good or excellent (p < 0.05). The subjective patient satisfaction score was 8.4 on a ten-point scale. All osteotomies healed and there were no complications. In this small series intra-articular osteotomy of the head of the radius was a safe and effective treatment for symptomatic intra-articular malunion without advanced degenerative changes


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1148 - 1155
1 Oct 2022
Watts AC Hamoodi Z McDaid C Hewitt C

Aims

Arthroplasties of the elbow, including total elbow arthroplasty, radial head arthroplasty, distal humeral hemiarthroplasty, and radiocapitellar arthroplasty, are rarely undertaken. This scoping review aims to outline the current research in this area to inform the development of future research.

Methods

A scoping review was undertaken adhering to the Joanna Briggs Institute guidelines using Medline, Embase, CENTRAL, and trial registries, limited to studies published between 1 January 1990 and 7 February 2021. Endnote software was used for screening and selection, and included randomized trials, non-randomized controlled trials, prospective and retrospective cohort studies, case-control studies, analytical cross-sectional studies, and case series of ten or more patients reporting the clinical outcomes of elbow arthroplasty. The results are presented as the number of types of studies, sample size, length of follow-up, clinical outcome domains and instruments used, sources of funding, and a narrative review.


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 112 - 123
1 Feb 2023
Duckworth AD Carter TH Chen MJ Gardner MJ Watts AC

Despite being one of the most common injuries around the elbow, the optimal treatment of olecranon fractures is far from established and stimulates debate among both general orthopaedic trauma surgeons and upper limb specialists. It is almost universally accepted that stable non-displaced fractures can be safely treated nonoperatively with minimal specialist input. Internal fixation is recommended for the vast majority of displaced fractures, with a range of techniques and implants to choose from. However, there is concern regarding the complication rates, largely related to symptomatic metalwork resulting in high rates of implant removal. As the number of elderly patients sustaining these injuries increases, we are becoming more aware of the issues associated with fixation in osteoporotic bone and the often fragile soft-tissue envelope in this group. Given this, there is evidence to support an increasing role for nonoperative management in this high-risk demographic group, even in those presenting with displaced and/or multifragmentary fracture patterns. This review summarizes the available literature to date, focusing predominantly on the management techniques and available implants for stable fractures of the olecranon. It also offers some insights into the potential avenues for future research, in the hope of addressing some of the pertinent questions that remain unanswered.

Cite this article: Bone Joint J 2023;105-B(2):112–123.


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1321 - 1326
1 Nov 2024
Sanchez-Sotelo J

Periprosthetic joint infection represents a devastating complication after total elbow arthroplasty. Several measures can be implemented before, during, and after surgery to decrease infection rates, which exceed 5%. Debridement with antibiotics and implant retention has been reported to be successful in less than one-third of acute infections, but still plays a role. For elbows with well-fixed implants, staged retention seems to be equally successful as the more commonly performed two-stage reimplantation, both with a success rate of 70% to 80%. Permanent resection or even amputation are occasionally considered. Not uncommonly, a second-stage reimplantation requires complex reconstruction of the skeleton with allografts, and the extensor mechanism may also be deficient. Further developments are needed to improve our management of infection after elbow arthroplasty.

Cite this article: Bone Joint J 2024;106-B(11):1321–1326.


Bone & Joint 360
Vol. 11, Issue 6 | Pages 31 - 34
1 Dec 2022

The December 2022 Shoulder & Elbow Roundup360 looks at: Biceps tenotomy versus soft-tissue tenodesis in females aged 60 years and older with rotator cuff tears; Resistance training combined with corticosteroid injections or tendon needling in patients with lateral elbow tendinopathy; Two-year functional outcomes of completely displaced midshaft clavicle fractures in adolescents; Patients who undergo rotator cuff repair can safely return to driving at two weeks postoperatively; Are two plates better than one? A systematic review of dual plating for acute midshaft clavicle fractures; Treatment of acute distal biceps tendon ruptures; Rotator cuff tendinopathy: disability associated with depression rather than pathology severity; Coonrad-Morrey total elbow arthroplasty implications in young patients with post-traumatic sequelae.


Bone & Joint 360
Vol. 12, Issue 2 | Pages 28 - 31
1 Apr 2023

The April 2023 Shoulder & Elbow Roundup360 looks at: Arthroscopic Bankart repair in athletes: in it for the long run?; Functional outcomes and the Wrightington classification of elbow fracture-dislocations; Hemiarthroplasty or ORIF intra-articular distal humerus fractures in older patients; Return to sport after total shoulder arthroplasty and hemiarthroplasty; Readmissions after shoulder arthroplasty; Arthroscopic Bankart repair in the longer term; Bankart repair with(out) remplissage or the Latarjet procedure? A systematic review and meta-analysis; Regaining motion among patients with shoulder pathology: are all exercises equal?


Bone & Joint 360
Vol. 13, Issue 3 | Pages 31 - 34
3 Jun 2024

The June 2024 Shoulder & Elbow Roundup360 looks at: Reverse versus anatomical total shoulder replacement for osteoarthritis? A UK national picture; Acute rehabilitation following traumatic anterior shoulder dislocation (ARTISAN): pragmatic, multicentre, randomized controlled trial; acid for rotator cuff repair: a systematic review and meta-analysis of randomized controlled trials; Metal or ceramic humeral head total shoulder arthroplasty: an analysis of data from the National Joint Registry; Platelet-rich plasma has better results for long-term functional improvement and pain relief for lateral epicondylitis: a systematic review and meta-analysis of randomized controlled trials; Quantitative fatty infiltration and 3D muscle volume after nonoperative treatment of symptomatic rotator cuff tears: a prospective MRI study of 79 patients; Locking plates for non-osteoporotic proximal humeral fractures in the long term; A systematic review of the treatment of primary acromioclavicular joint osteoarthritis.


Bone & Joint 360
Vol. 12, Issue 5 | Pages 30 - 34
1 Oct 2023

The October 2023 Shoulder & Elbow Roundup360 looks at: Arthroscopic capsular shift surgery in patients with atraumatic shoulder joint instability: a randomized, placebo-controlled trial; Superior capsular reconstruction partially restores native glenohumeral loads in a dynamic model; Gene expression in glenoid articular cartilage varies in acute instability, chronic instability, and osteoarthritis; Intra-articular injection versus interscalene brachial plexus block for acute-phase postoperative pain management after arthroscopic shoulder surgery; Level of pain catastrophizing rehab in subacromial impingement: secondary analyses from a pragmatic randomized controlled trial (the SExSI Trial); Anterosuperior versus deltopectoral approach for primary reverse total shoulder arthroplasty: a study of 3,902 cases from the Dutch National Arthroplasty Registry with a minimum follow-up of five years; Assessment of progression and clinical relevance of stress-shielding around press-fit radial head arthroplasty: a comparative study of two implants; A number of modifiable and non-modifiable factors increase the risk for elbow medial ulnar collateral ligament injury in baseball players: a systematic review.