To determine whether there is any difference in infection rate
at 90 days between trauma operations performed in laminar flow and
plenum ventilation, and whether infection risk is altered following
the installation of laminar flow (LF). We assessed the impact of plenum ventilation (PV) and LF on the
rate of infection for patients undergoing orthopaedic trauma operations.
All NHS hospitals in England with a trauma theatre(s) were contacted
to identify the ventilation system which was used between April
2008 and March 2013 in the following categories: always LF, never
LF, installed LF during study period (subdivided: before, during
and after installation) and unknown. For each operation, age, gender,
comorbidity, socio-economic deprivation, number of previous trauma
operations and surgical site infection within 90 days (SSI90) were
extracted from England’s national hospital administrative Hospital
Episode Statistics database. Crude and adjusted odds ratios (OR)
were used to compare ventilation groups using hierarchical logistic
regression. Subanalysis was performed for hip hemiarthroplasties.Aims
Patients and Methods
A pragmatic multicentre randomised controlled trial (PROFHER)
was conducted in United Kingdom National Health Service (NHS) hospitals
to evaluate the clinical effectiveness and cost effectiveness of
surgery compared with non-surgical treatment for displaced fractures
of the proximal humerus involving the surgical neck in adults. A cost utility analysis from the NHS perspective was performed.
Differences between surgical and non-surgical treatment groups in
costs and quality adjusted life years (QALYs) at two years were
used to derive an estimate of the cost effectiveness of surgery
using regression methods. Aims
Methods