Advertisement for orthosearch.org.uk
Results 1 - 20 of 20
Results per page:
The Bone & Joint Journal
Vol. 95-B, Issue 1 | Pages 132 - 134
1 Jan 2013
Barr LV Rehm A

Twins are often considered to be at an increased risk of developmental dysplasia of the hip (DDH); we therefore investigated whether multiple births have a higher incidence of DDH, and if selective ultrasound scanning should be considered for these infants.

We reviewed our records of all live births between 1 January 2004 and 31 December 2008 and included 25 246 single and 990 multiple births.

Multiple births did not have a significantly higher incidence of DDH compared with single births (0.0030 vs 0.0023, p = 0.8939). Of the 990 multiple births, 267 had neonatal ultrasound scans and one case of DDH was diagnosed and treated successfully with a Pavlik harness. There were two late-presenting cases at eight and 14 months of age, neither of whom had risk factors for DDH and consequently had not had a neonatal scan. Whereas selective ultrasound scanning of multiple births would have led to earlier detection and treatment of the late-presenting cases, they did not have a significantly higher incidence of DDH compared with single births.

We conclude that being a twin or triplet in itself is not a risk factor for DDH and that selective ultrasound scanning is not indicated for this population.

Cite this article: Bone Joint J 2013;95-B:132–4.


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1123 - 1130
1 Oct 2023
Donnan M Anderson N Hoq M Donnan L

Aims. The aim of this study was to investigate the agreement in interpretation of the quality of the paediatric hip ultrasound examination, the reliability of geometric and morphological assessment, and the relationship between these measurements. Methods. Four investigators evaluated 60 hip ultrasounds and assessed their quality based the standard plane of Graf et al. They measured geometric parameters, described the morphology of the hip, and assigned the Graf grade of dysplasia. They analyzed one self-selected image and one randomly selected image from the ultrasound series, and repeated the process four weeks later. The intra- and interobserver agreement, and correlations between various parameters were analyzed. Results. In the assessment of quality, there a was moderate to substantial intraobserver agreement for each element investigated, but interobserver agreement was poor. Morphological features showed weak to moderate agreement across all parameters but improved to significant when responses were reduced. The geometric measurements showed nearly perfect agreement, and the relationship between them and the morphological features showed a dose response across all parameters with moderate to substantial correlations. There were strong correlations between geometric measurements. The Graf classification showed a fair to moderate interobserver agreement, and moderate to substantial intraobserver agreement. Conclusion. This investigation into the reliability of the interpretation of hip ultrasound scans identified the difficulties in defining what is a high-quality ultrasound. We confirmed that geometric measurements are reliably interpreted and may be useful as a further measurement of quality. Morphological features are generally poorly interpreted, but a simpler binary classification considerably improves agreement. As there is a clear dose response relationship between geometric and morphological measurements, the importance of morphology in the diagnosis of hip dysplasia should be questioned. Cite this article: Bone Joint J 2023;105-B(10):1123–1130


Bone & Joint Open
Vol. 4, Issue 4 | Pages 234 - 240
3 Apr 2023
Poacher AT Froud JLJ Caterson J Crook DL Ramage G Marsh L Poacher G Carpenter EC

Aims. Early detection of developmental dysplasia of the hip (DDH) is associated with improved outcomes of conservative treatment. Therefore, we aimed to evaluate a novel screening programme that included both the primary risk factors of breech presentation and family history, and the secondary risk factors of oligohydramnios and foot deformities. Methods. A five-year prospective registry study investigating every live birth in the study’s catchment area (n = 27,731), all of whom underwent screening for risk factors and examination at the newborn and six- to eight-week neonatal examination and review. DDH was diagnosed using ultrasonography and the Graf classification system, defined as grade IIb or above or rapidly regressing IIa disease (≥4. o. at four weeks follow-up). Multivariate odds ratios were calculated to establish significant association, and risk differences were calculated to provide quantifiable risk increase with DDH, positive predictive value was used as a measure of predictive efficacy. The cost-effectiveness of using these risk factors to predict DDH was evaluated using NHS tariffs (January 2021). Results. The prevalence of DDH that required treatment within our population was 5/1,000 live births. The rate of missed presentation of DDH was 0.43/1000 live births. Breech position, family history, oligohydramnios, and foot deformities demonstrated significant association with DDH (p < 0.0001). The presence of breech presentation increased the risk of DDH by 1.69% (95% confidence interval (CI) 0.93% to 2.45%), family history by 3.57% (95% CI 2.06% to 5.09%), foot deformities by 8.95% (95% CI 4.81% to 13.1%), and oligohydramnios nby 11.6% (95 % CI 3.0% to 19.0%). Primary risk factors family history and breech presentation demonstrated an estimated cost-per-case detection of £6,276 and £11,409, respectively. Oligohydramnios and foot deformities demonstrated a cost-per-case detected less than the cost of primary risk factors of £2,260 and £2,670, respectively. Conclusion. The inclusion of secondary risk factors within a national screening programme was clinically successful as they were more cost and resource-efficient predictors of DDH than primary risk factors, suggesting they should be considered in the national guidance. Cite this article: Bone Jt Open 2023;4(4):234–240


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 991 - 998
1 May 2021
Lyu X Chen T Yang Z Fu G Feng C Zhang T Lu M

Aims. The objective of this study was to evaluate the clinical and radiological outcomes of patients younger than six months of age with developmental dysplasia of the hip (DDH) managed by either a Pavlik harness or Tübingen hip flexion splint. Methods. Records of 251 consecutive infants with a mean age of 89 days (SD 47), diagnosed with DDH between January 2015 and December 2018, were retrospectively reviewed. Inclusion criteria for patients with DDH were: younger than 180 days at the time of diagnosis; ultrasound Graf classification of IIc or greater; treatment by Pavlik harness or Tübingen splint; and no prior treatment history. All patients underwent hip ultrasound every seven days during the first three weeks of treatment and subsequently every three to four weeks until completion of treatment. If no signs of improvement were found after three weeks, the Pavlik harness or Tübingen splint was discontinued. Statistical analysis was performed. Results. The study included 251 patients with Graf grades IIc to IV in 18 males and 233 females with DDH. Mean follow-up time was 22 months (SD 10). A total of 116 hips were graded as Graf IIc (39.1%), nine as grade D (3.0%), 100 as grade III (33.7%), and 72 as grade IV (24.2%). There were 109 patients (128 hips) in the Pavlik group and 142 patients (169 hips) in the Tübingen group (p = 0.227). The Tübingen group showed a 69.8% success rate in Graf III and Graf IV hips while the success rate was significantly lower in the Pavlik group, 53.9% (p = 0.033). For infants older than three months of age, the Tübingen group showed a 71.4% success rate, and the Pavlik group a 54.4% success rate (p = 0.047). Conclusion. The Tübingen splint should be the preferred treatment option for children older than three months, and for those with severe forms of DDH such as Graf grade III and IV, who are younger than six months at time of diagnosis. The Tübingen hip flexion splint is a valid alternative to the Pavlik harness for older infants and those with more severe DDH. Cite this article: Bone Joint J 2021;103-B(5):991–998


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 2 | Pages 321 - 324
1 Mar 1998
Bar-On E Meyer S Harati G Porat S

Ultrasonography of the hip was performed sequentially by two different examiners in 75 infants. The ultrasound strips were reviewed twice by three paediatric orthopaedic surgeons and classified by the Graf method. The intraobserver and interobserver agreement between the interpretations was analysed using simple and weighted kappa coefficients calculated for agreement on the Graf classification and for grouping as normal (types 1A to 2A), and abnormal requiring treatment (types 2B to 4). When examining the same ultrasound strip, intraobserver agreement for the Graf classification was substantial (mean kappa 0.61), but interobserver agreement was only moderate (kappa 0.50). For the grouping into normal and abnormal, the mean kappa value for intraobserver agreement was 0.67 and for interobserver agreement 0.57. Because of the significant differences in agreement between normal and abnormal hips, we analysed a subgroup of those with at least one abnormal interpretation. Intraobserver agreement within this subgroup showed moderate reliability (kappa 0.41), but interobserver agreement was only fair (kappa 0.28). Interpretations of two different strips performed sequentially showed significantly lower agreement with an intraobserver kappa value of 0.29 and an interobserver value of 0.28. In the subgroup with at least one abnormal reading, the intraobserver kappa was 0.09 and the interobserver 0.1. Our findings suggest that both the technique of performing ultrasonography and the interpretation of the image may influence the result


Bone & Joint Open
Vol. 5, Issue 1 | Pages 3 - 8
2 Jan 2024
Husum H Hellfritzsch MB Maimburg RD Møller-Madsen B Henriksen M Lapitskaya N Kold S Rahbek O

Aims

The present study seeks to investigate the correlation of pubofemoral distances (PFD) to α angles, and hip displaceability status, defined as femoral head coverage (FHC) or FHC during manual provocation of the newborn hip < 50%.

Methods

We retrospectively included all newborns referred for ultrasound screening at our institution based on primary risk factor, clinical, and PFD screening. α angles, PFD, FHC, and FHC at follow-up ultrasound for referred newborns were measured and compared using scatter plots, linear regression, paired t-test, and box-plots.


The Bone & Joint Journal
Vol. 99-B, Issue 11 | Pages 1533 - 1536
1 Nov 2017
Nie K Rymaruk S Paton RW

Aims. A clicky hip is a common referral for clinical and sonographic screening for developmental dysplasia of the hip (DDH). There is controversy regarding whether it represents a true risk factor for pathological DDH. Therefore a 20-year prospective, longitudinal, observational study was undertaken to assess the relationship between the presence of a neonatal clicky hip and pathological DDH. Patients and Methods. A total of 362 infants from 1997 to 2016 were referred with clicky hips to our ‘one-stop’ paediatric hip screening clinic. Hips were assessed clinically for instability and by ultrasound imaging using a simplified Graf/Harcke classification. Dislocated or dislocatable hips were classified as Graf Type IV hips. Results. The mean age at presentation was 13.8 weeks (12.8 to 14.7). In all 351 out of 362 children (97.0%) had Graf Type I hips (normal) that required no treatment. Nine children (2.5%) had Graf Type II hips but all resolved to Graf Type I hips on follow-up scans. One child (0.3%) had Graf Type III hip dysplasia and one child (0.3%) had an irreducible hip dislocation. The two pathological hips were associated with unilateral limited hip abduction. Mean referrals increased from 12.9 to 23.3 each year (p = 0.002) from the first decade of the study to the second, driven by increasing primary care referrals (5.5 versus 16.7 per year, p < 0.001). Conclusion. Most clicky hips required no treatment other than reassurance to parents. Clicky hips with a normal hip examination should be considered a variant of normal childhood and not a risk factor for DDH. However, an abnormal hip examination including unilateral limited hip abduction should prompt urgent further investigations. Cite this article: Bone Joint J 2017;99-B:1533–6


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 5 | Pages 726 - 730
1 Jul 2003
Roovers EA Boere-Boonekamp MM Geertsma TSA Zielhuis GA Kerkhoff AHM

We studied the reproducibility of ultrasonographic screening examination of the hip when read by diagnostic radiographers. In order to determine interobserver variability, 200 ultrasonograms were classified according to Graf’s method by five observers (four radiographers and one radiologist). The kappa values for interobserver variability indicated moderate agreement (kappa 0.47) for the exact Graf classification and substantial agreement (kappa 0.65) for the classification of normal (type I) versus abnormal (type IIa-IV). Agreement was significantly different for normal, immature and abnormal hips. Comparison of the findings in our interobserver study with existing information based on other examinations and treatment revealed that only a small number of infants with mildly dysplastic hips would have been typed as normal by some observers as a result of observer variability. In conclusion, the interobserver agreement on the ultrasound assessment of the hip was good enough for screening purposes. Observer variability did not result in any severe cases being missed


Bone & Joint Open
Vol. 4, Issue 8 | Pages 635 - 642
23 Aug 2023
Poacher AT Hathaway I Crook DL Froud JLJ Scourfield L James C Horner M Carpenter EC

Aims

Developmental dysplasia of the hip (DDH) can be managed effectively with non-surgical interventions when diagnosed early. However, the likelihood of surgical intervention increases with a late presentation. Therefore, an effective screening programme is essential to prevent late diagnosis and reduce surgical morbidity in the population.

Methods

We conducted a systematic review and meta-analysis of the epidemiological literature from the last 25 years in the UK. Articles were selected from databases searches using MEDLINE, EMBASE, OVID, and Cochrane; 13 papers met the inclusion criteria.


Bone & Joint Open
Vol. 2, Issue 8 | Pages 594 - 598
3 Aug 2021
Arneill M Cosgrove A Robinson E

Aims

To determine the likelihood of achieving a successful closed reduction (CR) of a dislocated hip in developmental dysplasia of the hip (DDH) after failed Pavlik harness treatment We report the rate of avascular necrosis (AVN) and the need for further surgical procedures.

Methods

Data was obtained from the Northern Ireland DDH database. All children who underwent an attempted closed reduction between 2011 and 2016 were identified. Children with a dislocated hip that failed Pavlik harness treatment were included in the study. Successful closed reduction was defined as a hip that reduced in theatre and remained reduced. Most recent imaging was assessed for the presence of AVN using the Kalamchi and MacEwen classification.


The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 266 - 270
1 Feb 2013
Uludag S Seyahi A Orak MM Bilgili MG Colakoglu B Demirhan M

Several authors have suggested that the final five weeks of gestation are a critical period for the development of the hip. In order to test the hypothesis that gestational age at birth may influence the development of the hip joint, we analysed the sonographic findings in 1992 hips (in 996 term newborns) with no risk factor for developmental dysplasia of the hip. The 996 infants were born at a mean gestational age of 39 weeks (37 to 41).

The mean bony roof angle (α), cartilage roof angle (β) and the distribution of the type of hip were compared between the 37th, 38th, 39th, 40th and 41st birth week groups. There was a significant difference in the distribution of type of hip between the different birth week groups (p < 0.001), but no significant difference between the α angles of all groups (p = 0.32). There was no correlation between birth week and roof angle (p = 0.407 and p = 0.291, respectively) and no significant correlation between birth weight and roof angle (p = 0.735 and p = 0.132, respectively).

The maturity of the infant hip, as assessed sonographically, does not appear to be affected by gestational age, and the fetal development of the acetabular roof appears to plateau from 37 weeks.

Cite this article: Bone Joint J 2013;95-B:266–70.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 11 | Pages 1586 - 1588
1 Nov 2010
Perry DC Tawfiq SM Roche A Shariff R Garg NK James LA Sampath J Bruce CE

The association between idiopathic congenital talipes equinovarus (CTEV) and developmental dysplasia of the hip is uncertain. We present an observational cohort study spanning 6.5 years of selective ultrasound screening of hips in clubfoot. From 119 babies with CTEV there were nine cases of hip dysplasia, in seven individuals. This suggests that 1 in 17 babies with CTEV will have underlying hip dysplasia.

This study supports selective ultrasound screening of hips in infants with CTEV.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 7 | Pages 1013 - 1016
1 Jul 2010
Walton MJ Isaacson Z McMillan D Hawkes R Atherton WG

We present the results of treatment of developmental dysplasia of the hip in infancy with the Pavlik harness using a United Kingdom screening programme with ultrasound-guided supervision. Initially, 128 consecutive hips in 77 patients were reviewed over a 40-month period; 123 of these were finally included in the study. The mean age of the patients at the start of treatment was five weeks (1 to 12). All hips were examined clinically and monitored with ultrasound scanning. Failure of treatment was defined as an inability to maintain reduction with the harness. All hips diagnosed with dysplasia or subluxation but not dislocation were managed successfully in the harness. There were 43 dislocated hips, of which 39 were reducible, but six failed treatment in the harness. There were four dislocated but irreducible hips which all failed treatment in the harness. One hip appeared to be successfully treated in the harness but showed persistent radiological dysplasia at 12 and 24 months. Grade 1 avascular necrosis was identified radiologically in three patients at 12 months.


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1553 - 1555
1 Nov 2014
Paton RW Choudry QA Jugdey R Hughes S

There is controversy whether congenital foot abnormalities are true risk factors for pathological dysplasia of the hip. Previous United Kingdom screening guidelines considered congenital talipes equinovarus (CTEV) to be a risk factor for hip dysplasia, but present guidelines do not. We assessed the potential relationship between pathological dysplasia of the hip and fixed idiopathic CTEV.

We present a single-centre 21-year prospective longitudinal observational study. All fixed idiopathic CTEV cases were classified (Harrold and Walker Types 1 to 3) and the hips clinically and sonographically assessed. Sonographic Graf Type III, IV and radiological irreducible hip dislocation were considered to be pathological hip dysplasia.

Over 21 years there were 139 children with 199 cases of fixed idiopathic CTEV feet. Sonographically, there were 259 normal hips, 18 Graf Type II hips, 1 Graf Type III hip and 0 Graf Type IV hip. There were no cases of radiological or sonographic irreducible hip dislocation.

Fixed idiopathic CTEV should not be considered as a significant risk factor for pathological hip dysplasia. This conclusion is in keeping with the current newborn and infant physical examination guidelines in which the only risk factors routinely screened are family history and breech presentation. Our findings suggest CTEV should not be considered a significant risk factor in pathological dysplasia of the hip.

Cite this article: Bone Joint J 2014;96-B:1553–5.


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 265 - 269
1 Feb 2015
Mace J Paton RW

Over a 15-year prospective period, 201 infants with a clinically unstable hip at neonatal screening were subsequently reviewed in a ‘one stop’ clinic where they were assessed clinically and sonographically. Their mean age was 1.62 weeks (95% confidence interval (CI) 1.35 to 1.89). Clinical neonatal hip screening revealed a sensitivity of 62% (mean, 62.6 95%CI 50.9 to 74.3), specificity of 99.8% (mean, 99.8, 95% CI 99.7 to 99.8) and positive predictive value (PPV) of 24% (mean, 26.2, 95% CI 19.3 to 33.0). Static and dynamic sonography for Graf type IV dysplastic hips had a 15-year sensitivity of 77% (mean, 75.8 95% CI 66.9 to 84.6), specificity of 99.8% (mean, 99.8, 95% CI 99.8 to 99.8) and a PPV of 49% (mean, 55.1, 95% CI 41.6 to 68.5). There were 36 infants with an irreducible dislocation of the hip (0.57 per 1000 live births), including six that failed to resolve with neonatal splintage.

Most clinically unstable hips referred to a specialist clinic are female and stabilise spontaneously. Most irreducible dislocations are not identified from this neonatal instability group. There may be a small subgroup of females with instability of the hip which may be at risk of progression to irreducibility despite early treatment in a Pavlik harness.

A controlled study is required to assess the value of neonatal clinical screening programmes.

Cite this article: Bone Joint J 2015;97-B:265-9.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 6 | Pages 842 - 847
1 Jun 2012
Eberhardt O Fernandez FF Wirth T

We present our early experience of arthroscopic reduction of the dislocated hip in very young infants with developmental dysplasia of the hip (DDH).

Eight dislocated hips, which had failed attempts at closed reduction, were treated by arthroscopy of the hip in five children with a mean age of 5.8 months (4 to 7). A two-portal technique was used, with a medial sub-adductor portal for a 2.7 mm cannulated system with a 70° arthroscope and an anterolateral portal for the instruments. Following evaluation of the key intra-articular structures, the hypertrophic ligamentum teres and acetabular pulvinar were resected, and a limited release of the capsule was performed prior to reduction of the hip. All hips were reduced by a single arthroscopic procedure, the reduction being confirmed on MRI scan. None of the hips had an inverted labrum. The greatest obstacle to reduction was a constriction of the capsule. At a mean follow-up of 13.2 months (9 to 24), all eight hips remained stable. Three developed avascular necrosis. The mean acetabular index decreased from 35.5° (30° to 40°) pre-operatively to 23.3° (17° to 28°).

This study demonstrates that arthroscopic reduction is feasible using two standardised portals. Longer follow-up studies are necessary to evaluate the functional results.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 12 | Pages 1695 - 1699
1 Dec 2010
Fox AE Paton RW

This prospective cohort study aimed to investigate the relationship between developmental dysplasia of the hip and mode of delivery in 571 consecutive breech infants using a modified Graf’s static morphological method to grade the severity of dysplasia.

In this group, 262 infants were born by planned Caesarian section, 223 by emergency section and 86 vaginally. Taking all grades of hip dysplasia into account (Graf types II, III and IV), there was no statistical difference in the incidence of dysplasia between the groups (elective section 8.4%, emergency section 8.1% and vaginal delivery 7.0%). However, when cases with Graf type II dysplasia, which may represent physiological immaturity, were excluded, the rate of type III and IV hips, which we consider to be clinically relevant, increased in the vaginally delivered group (4.7%) compared with the elective section group (1.1%), with a relative risk of approximately 1:4 (95% confidence interval 1.03 to 15.91). No difference was observed between the emergency and elective section groups, or between the emergency section and vaginally delivered groups.

This study supports previous published work, with the added value that the diagnoses were all confirmed by ultrasound.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 5 | Pages 655 - 658
1 May 2009
Paton RW Choudry Q

In a prospective study over 11 years we assessed the relationship between neonatal deformities of the foot and the presence of ultrasonographic developmental dysplasia of the hip (DDH). Between 1 January 1996 and 31 December 2006, 614 infants with deformities of the foot were referred for clinical and ultrasonographic evaluation. There were 436 cases of postural talipes equinovarus deformity (TEV), 60 of fixed congenital talipes equinovarus (CTEV), 93 of congenital talipes calcaneovalgus (CTCV) and 25 of metatarsus adductus.

The overall risk of ultrasonographic dysplasia or instability was 1:27 in postural TEV, 1:8.6 in CTEV, 1:5.2 in CTCV and 1:25 in metatarsus adductus.

The risk of type-IV instability of the hip or irreducible dislocation was 1:436 (0.2%) in postural TEV, 1:15.4 (6.5%) in CTCV and 1:25 (4%) in metatarsus adductus. There were no cases of hip instability (type IV) or of irreducible dislocation in the CTEV group.

Routine screening for DDH in cases of postural TEV and CTEV is no longer advocated. The former is poorly defined, leading to the over-diagnosis of a possibly spurious condition. Ultrasonographic imaging and surveillance of hips in infants with CTCV and possibly those with metatarsus adductus should continue.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 8 | Pages 1090 - 1093
1 Aug 2009
van der Sluijs JA De Gier L Verbeke JI Witbreuk MMEH Pruys JEH van Royen BJ

We prospectively studied the benefits and risks of prolonged treatment with the Pavlik harness in infants with idiopathic developmental dysplasia of the hip. Bracing was continued as long as abduction improved. It was started at a mean age of four months (1 to 6.9). Outcome measures were the number of successful reductions, the time to reduction, the acetabular index and evidence of avascular necrosis at follow-up at one year.

In 50 infants with 62 subluxated and dislocated hips (42 Graf type III and 20 type IV), 37 were reduced successfully with a mean time to reduction of 13.4 weeks (sd 6.8). Bracing was successful in 31 type-III (73.8%) and in only six type-IV hips (20%, p = 0.002). Avascular necrosis was seen in ten hips.

Prolonged treatment with the Pavlik harness for developmental dysplasia of the hip over the age of one month can be beneficial in type-III hips, but it is unclear as to whether this is the optimal treatment, since it may postpone the need for closed or open reduction to a more unfavourable age. The use of the Pavlik harness in type-IV hips in this age group is questionable, but if used, prolonged bracing is not advised.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 9 | Pages 1264 - 1266
1 Sep 2005
Paton RW Hinduja K Thomas CD

Of the 34 723 infants born between 1 June 1992 and 31 May 2002, the hips of 2578 with clinical instability or at-risk factors for developmental dysplasia of the hip were imaged by ultrasound.

Instability of the hip was present in 77 patients, of whom only 24 (31.2%) had an associated risk factor. From the ‘at-risk’ groups, the overall risk of type-III dysplasia, instability and irreducibility was 1:15 when family history, 1:27 when breech delivery and 1:33 when foot deformity were considered as risk factors. Of those hips which were ultrasonographically stable, 88 had type-III dysplasia.

A national programme of selective ultrasound screening of at-risk factors for the diagnosis of hip dislocation or instability alone cannot be recommended because of its low predictive value (1:88). However, the incidence of type-III dysplasia and hip dislocation or dislocatability in the groups with clinical instability, family history, breech position and possibly postural foot deformity as risk factors could justify a programme of selective ultrasound imaging.